This document provides an amendment to a solicitation for the Atchafalaya Basin Floodway Bayou Sorrel Lock Southwest Guidewall and Dolphin Replacement project in Iberville Parish, Louisiana. The amendment revises drawings and specifications, establishes a revised proposal due date of July 1, 2021, provides responses to contractor questions, and identifies a small business set-aside for the solicitation. Relevant details include steel pipe piles, timber guidewall construction, dolphin construction with concrete formwork designed to withstand a 1,485 kip impact load, electrical work, and UHMWPE rub rails. The contracting agency is the Department of the Army Corps of Engineers New Orleans District. Landside staging areas and access routes are also specified.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to provide answ ers to contractors questions and establish a revised proposal due date of 2 July 2021 at 1:00 PM CST. No further questions and answers w ill be addressed.

1. CONTRACT ID CODE PAGE OF PAGES

1 2

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 23-Jun-2021

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912P820R0087

X 9B. DATED (SEE ITEM 11)

13-May-2021

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

23-Jun-2021

CODE

USACE, CONTRACTING DIVISION

ATTN: CEMVN-CT, ROOM 172

7400 LEAKE AVE.

NEW ORLEANS LA 70118-3651

W912P8 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912P820R0087

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

(End of Summary of Changes)

SECTION 00010

Pages 00010-3, 4, and 5. Delete these pages in their entirety and substitute the attached revised pages 00010-3, 4, and 5, therefore.

SECTION 01100

1. Paragraph 12, LOCK CLOSURES. Delete this paragraph in its entirety and substitute the following therefore:

“12. LOCK CLOSURES

The Bayou Sorrel Lock will experience some lock closures. The following requirements shall be considered and/or adhered to: (a) Lock closures and obstructions to navigation are permitted only between 7:00 a.m. and 7:00 p.m., Monday through Thursday. (b) If, in the opinion of the Contracting Officer, lock closures or navigation obstruction result in an unacceptable backlog of vessels waiting for lockage, the Contracting Officer may direct the Contractor to cease work. The Contracting Officer may issue as many cease work directives as necessary during the contract period. Payment while under a cease work directive will be paid for in accordance with the Section 00700 Contract Clause entitled SUSPENSION OF

WORK (FAR 52.242-14.”

2. Paragraph 16, HIGH WATER RESTRICTIONS. Delete this paragraph in its entirety and substitute the following therefore:

“16. HIGH RIVER RESTRICTIONS

At such time that the Atchafalaya River is at or above elevation +5.0 feet, NAVD 88 (2004.65) at the Morgan City gage, all construction work related to pile driving activities shall cease until such time as the elevation subsides below +5.0 feet. Updated information on gage readings may be obtained by contacting (504) 862-2461 (recording) or logon onto www.RiverGages.com. Delays to the Contractor's operations from ceasing work when the Atchafalaya River elevation is above +5.0 feet at the Morgan City gage will be subject to the provisions of Section 00700 Contract Clause entitled DEFAULT (FIXED-PRICE CONSTRUCTION) (FAR 52.249-10). A waiver to this restriction will be reviewed and granted by the Contracting Officer on a case by case basis.”

3. Paragraph 24, NOTICE TO NAVIGATION. Delete this paragraph in its entirety and substitute the following therefore:

“24. NOTICE TO NAVIGATION

The Contractor shall notify the Contracting Officer at least 21 days before any equipment, materials, etc. arrive at the site. This notification shall contain the Contractor’s proposed schedule of work which shall include the estimated closure and/or navigation obstruction file://mvd/mvn/Data_EDS/DistrictSpecs/!-FILES/ed--Structure/18-xxx/18-078/Am_0004/www.RiverGages.com times. The Government will issue bulletins to navigation interests concerning closures due to the construction work being performed. The bulletins will include the schedules and estimates provided by the Contractor. Any deviations from the schedule of work shall be reported as soon as possible so that additional navigation bulletins can be issued to navigation interests.”

DRAWINGS

SHEET IDENTIFICATION Nos: C-100, C-102, and E-100. Delete these drawings in their entirety and substitute the attached revised drawings SHEET IDENTIFICATION Nos: C-100, C-102, and E-100 therefore.

00010-3 ED 18-078

SECTION 00010 – BIDDING SCHEDULE

Atchafalaya Basin Floodway, Bayou Sorrel Lock, Southwest Guidewall and Dolphin Replacement

Iberville Parish, Louisiana

Item DESCRIPTION Estimated Quantity Unit Unit Price Estimated Amount

0001 Mobilization and Demobilization 1 JOB

0002 Demolition 1 JOB

0003 Dolphin Construction 1 JOB

0004 UHMWPE Rub Rails 1 JOB

0005 Electrical Work 1 JOB

0006 Steel Pipe Piles 26 EA

0007 Timber Guidewall Construction 1 JOB

0008 Pile Shoes

0008AA First 60 Pile Shoes 60 EA

0008AB All Over 60 Pile Shoes 10 EA

TOTAL $

Award will be made as a whole to one bidder.

NOTE 1: The unit “JOB” as used in this Bidding Schedule is synonymous with the term “LUMP SUM” used elsewhere within these plans and specifications.

NOTE 2: Bidders shall furnish unit prices for each item listed in the Schedule requiring a unit price. If the bidder fails to insert a unit price in the appropriate blank for required item(s), but does furnish an extended total, or an estimated amount for such item(s), the Government shall deem the unit price to be the quotient obtained by dividing the extended amount for that line item by the quantity. IF A BIDDER OMITS BOTH THE

UNIT PRICE AND THE EXTENDED TOTAL OR ESTIMATED AMOUNT FOR ANY

ITEM, ITS BID SHALL BE DECLARED NON-RESPONSIVE AND THEREFORE

INELIGIBLE FOR AWARD.

NOTE 3: Any bid may be rejected if the Contracting Officer determines in writing that it is unreasonable as to price. Unreasonableness of price includes not only total price of bid, but the price for individual line items as well. Any bid may be rejected if the prices for any line items or sub line items are materially unbalanced (See FAR 14.404-2 Rejection of Individual Bids).

00010-4 ED 18-078

NOTE 4: THE NOTICE TO PROCEED (NTP): The successful bidder is advised that performance and payment bonds shall be submitted in accordance with the time frame in block 12B of SF 1442. The NTP will be issued immediately after verification of acceptable performance and payment bonds. Within seven (7) days after issuance of the NTP, the Contractor shall initiate a meeting to discuss the submittal process with the Area or Resident Engineer or his authorized representative. Physical work cannot start until the Accident Prevention Plan, Contractor Quality Control Plan, and other submittals which may be required, have been submitted and approved and all preliminary meetings called for under the contract, have been conducted.

NOTE 5: RAPID VENDOR PAYMENT: Web based instructions for the submission of invoices;

http://www.mvn.usace.army.mil/BusinessWithUs/Contracting/RapidVendorPayment.aspx http://www.mvn.usace.army.mil/ebs/rapid_vendor_payment.asp

00010-5 ED 18-078

EVALUATION OF SUBLINE ITEMS (Dec 2019 - AFARS 5152.211-9000).

Item No. 0008 is subdivided into two or more estimated quantities and are to be separately priced. The Government will evaluate each of these items on the basis of total price of its subline items.

(End of Clause)

VARIATIONS IN ESTIMATED QUANTITIES - SUBLINE ITEMS (Dec 2019 –

AFARS 5152.211-9001).

This variation in estimated quantities clause is applicable only to item No. 0008.

(a) Variation from the estimated quantity in the actual work performed under any second or subsequent subline item or elimination of all work under such a second or subsequent subline item will not be the basis for an adjustment in contract unit price.

(b) Where the actual quantity of work performed for item No. 0008 is less than 85% of the quantity of the first subline item listed under such item, the Contractor will be paid at the contract unit price for that subline item for the actual quantity of work performed and, in addition, an equitable adjustment shall be made in accordance with the clause at Federal Acquisition Regulation (FAR) 52.211-18, VARIATION IN ESTIMATED QUANTITY.

(c) If the actual quantity of work performed under item No. 0008 exceeds 115% or is less than 85% of the total estimated quantity of the subline item under that item and/or if the quantity of the work performed under the second subline item or any subsequent subline item under item Nos. NONE exceeds 115% or is less than 85% of the estimated quantity of any such subline item, and if such variation causes an increase or a decrease in the time required for performance of this contract the contract completion time will be adjusted in accordance with the clause FAR 52.211-18, VARIATION IN ESTIMATED QUANTITY.

(End of Clause)

C-100

S

IT

E P

L A

N

H

C -1

.d g n U

P D

A T

E D

C O

O R

D

IN

A T

E

J U

N /2

,0

3,284,000

TOE OF LEVEE

BAYOU SORREL LOCK

TOE OF LEVEE EXISTING TIMBER GUIDEWALL

EXISTING RIPRAP

UNDISTURBED TYPE BORING

FOREBAYTAILBAY

GAGE, SEE HYDROGRAPHS

TOE OF LEVEE

,0

,0

,0

TOE O

F L

EVEE

TOE O

F L

EVEE

91°19'30''

91º19'15''

3,285,000TOE OF LEVEE

TOE OF LEVEE

TOE OF LEVEE

,0

,0

3,285,000 91º19'15''

91°19'30''

NOTES

LEGEND

B A

SITE PLAN

T O

E O

F L

E V

E E

SHORELINE

EXISTING LEVEE

FENCE

STA. 19+74 TO REMAIN IN PLACE

FROM LOCK CHAMBER TO

EXISTING TIMBER GUIDEWALL

NEW TIMBER GUIDEWALL AND DOLPHIN

C-102 C-102

REQUIRED ROW

STAGING AREA

PROPOSED

PROPOSED STAGING AREA

REFERENCE SHEET R-001

TO BE REMOVED. SEE

EXISTING PILE CLUSTER

1 2

STAGING AREA

PROPOSED LAND

STAGING AREA COORDINATES

PT. X Y

3284213.84 592966.37

3284264.11 592656.97

592640.863284164.95

3284125.41 592884.19

592934.253284140.22

592961.713284185.16

594260.503283941.79

592979.733284181.12

592927.103283827.64

593039.063284100.58

N

FOR DETAILS.

TO BE REMOVED. SEE R-002

SHEET PILE FENDERS

EXISTING QUARTER ROUND

RIGHT OF WAY COORDINATES

PT. X Y

3284749.78 593073.96

3284315.83 593003.45

592140.133284456.12

3284244.34 592105.72

592980.153284102.25

592939.743283853.55

593778.363283716.40

593927.343283825.31

594243.073283884.71

594340.853284376.80

594092.343284434.38

593967.903284516.76

593303.453284640.36

593248.813284669.57

593210.253284718.07

200'0 100'

SCALE:1"=100'

12234

GUIDEWALL AND DOLPHIN

PROPOSED SOUTHWEST

SEE R-001 FOR DETAILS

TO BE REMOVED & REPLACED

FROM STA. 19+74 TO ± STA. 16+92

EXISTING TIMBER GUIDEWALL

4BYSU

3BYSU

1BYSU

2BYSU

251-UE

251-AUE

250-UE

250-AUE

5. CONTRACTOR SHALL NOT IMPEDE NAVIGATION.

4. CONTRACTOR WILL NOT BE GIVEN PRIORITY FOR LOCKAGE.

CONSTRUCTION.

3. AN ORGANIZED SITE VISIT WILL BE PERFORMED PRIOR TO

WALES, BRACES, ETC.

2. DIVERS MAY BE REQUIRED TO INSTALL RUB RAILS, NEW

1. FLOTATION CHANNEL EXCAVATION WILL NOT BE ALLOWED.

BASELINE STATION COORDINATES

X Y

3284810.77 591064.43

3283992.96 596088.04

STATION

0+00

50+90

STA. X

592688.840

Y

GUIDEWALL OFFSET FROM BASELINE

16+95.28

OFFSET

309.89'L 3284229.475

17+57.40 282.38'L 3284247.342 592752.178

18+50.53 268.50'L 3284245.969 592847.859

3284225.668 592984.484266.78'L19+90.19

PT.

11 593002.013283872.54

3284213.84 592966.37

3283757.44 593144.53

593229.993283704.00

3283732.46 593277.43

YXPT.

15 593575.433283551.73

3283343.04 593433.18

17 3283570.14 593048.97

SITE

TRAILER

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D

A T

E

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

D A

T E

A P

P R

®of Engineers

US Army Corps

ID

Sheet of Engineers

US Army Corps

NEW ORLEANS DISTRICT

N E

W O

R L

E A

N S

L

O U

IS

IA

N A

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

N E

W O

R L

E A

N S

D

IS

T R

IC

T

A T

C H

A L

A F

A Y

A B

A S

IN

F

L O

O D

W A

Y

IB

E

R V

IL

L

E P

A R

IS

H

L

O U

IS

IA

N A

A .C

.E

S O

U T

H W

E S

T G

U

ID

E W

A L

L

D O

L P

H

IN

R E

P L

A C

E M

E N

T

D a v id P

L o v e tt

P

.E

H -4

-4

W P

-X

M M

/D D

/Y Y

Y Y

A N

S I

D

X X

X X

:1

D J H

W P

-X

B A

Y O

U S

O R

R E

L L

O C

K J U

N E

U m a r

R a ja

/I ra

W

D o rs e tt

C-102

E X

IS

T

IN

G

S E

C T

IO

N

S

H C

-1 .d g n

R E

V

IS

E D

S T

A G

G

IN

G A

R E

A J U

N /2

-1

0 2

20E L

E V

A T

IO

N

I N

F E

E T

N A

V D

EAST SIDE WEST SIDE

20 E L

E V

A T

IO

N

I N

F E

E T

N A

V D

20E L

E V

A T

IO

N

I N

F E

E T

N A

V D

EAST SIDE WEST SIDE

20 E L

E V

A T

IO

N

I N

F E

E T

N A

V D

-1

0 2

DISTANCE IN FEET

DISTANCE IN FEET

EL. -8

EXISTING SOUTHWEST GUIDEWALL

CHANNEL SIDE FACE OF

SOUTHEAST GUIDEWALL

EXISTING

FACE OF

CHANNEL SIDE

STA. 17+52

STA. 18+52

EL. -8

EXISTING SOUTHWEST GUIDEWALL

CHANNEL SIDE FACE OF

SOUTHEAST GUIDEWALL

EXISTING

FACE OF

CHANNEL SIDE

PROPOSED SOUTHWEST GUIDEWALL

STAGING AREA

PROPOSED CONTRACTOR

STAGING AREA

PROPOSED CONTRACTOR

SCALE: 1"=20'-0"

SECTIONA

C-100

SCALE: 1"=20'-0"

SECTIONB

C-100

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D

A T

E

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

D A

T E

A P

P R

®of Engineers

US Army Corps

ID

Sheet of Engineers

US Army Corps

NEW ORLEANS DISTRICT

N E

W O

R L

E A

N S

L

O U

IS

IA

N A

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

N E

W O

R L

E A

N S

D

IS

T R

IC

T

A T

C H

A L

A F

A Y

A B

A S

IN

F

L O

O D

W A

Y

IB

E

R V

IL

L

E P

A R

IS

H

L

O U

IS

IA

N A

A .C

.E

S O

U T

H W

E S

T G

U

ID

E W

A L

L

D O

L P

H

IN

R E

P L

A C

E M

E v id P

L o v e tt

P

.E

H -4

-4

W P

-X

M M

/D D

/Y Y

Y Y

A N

S I

D

X X

X X

:1

D J H

W P

-X

B A

Y O

U S

O R

R E

L L

O C

K J U

N E

U m a r

R a ja

/I ra

W

D o rs e tt

E

W O

R L

E A

N S

D

IS

T R

IC

T

N E

W O

R L

E A

N S

L

O U

IS

IA

N A

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

E-100

E L

E C

T R

IC

A

L P

L A

N A

N D

D E

T A

IL

S

H E

-1 .d g n

U P

D A

T E

D G

U

IL

D W

A L

L J U

N /2

S O

L

IC

IT

A

T

IO

N N

O

F

IL

E N

A M

E

D W

N B

Y

C K

D B

Y

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

D

2 3

C

4 5

A

B

M A

R K

A P

P R

D

A T

E

F

IL

E N

U M

B E

R

S I Z

E

S U

B M

IT

T

E D

B Y

P L

O T

S C

A L

E P

L O

T D

A T

E

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

C O

N T

R A

C T

N O

D A

T E

A P

P R

®of Engineers

US Army Corps

ID

Sheet of Engineers

US Army Corps

NEW ORLEANS DISTRICT

N E

W O

R L

E A

N S

L

O U

IS

IA

N A

U .S

A

R M

Y C

O R

P S

O F

E N

G

IN

E E

R S

N E

W O

R L

E A

N S

D

IS

T R

IC

T

A T

C H

A L

A F

A Y

A B

A S

IN

F

L O

O D

W A

Y

IB

E

R V

IL

L

E P

A R

IS

H

L

O U

IS

IA

N A

A .C

.E

S O

U T

H W

E S

T G

U

ID

E W

A L

L

D O

L P

H

IN

R E

P L

A C

E M

E v id P

L o v e tt

P

.E

H -4

-4

W P

-X

M M

/D D

/Y Y

Y Y

A N

S I

D

X X

X X

:1

D J H

W P

-X

B A

Y O

U S

O R

R E

L L

O C

K J U

N E

U m a r

R a ja

/I ra

W

D o rs e tt

WALES TO BE IN LINE

WITH FACE OF LOCK WALL

EXISTING

CIRCUIT

EXISTING LIGHTING

HOME RUN TO PANEL

CIRCUIT END

LIGHT POWER

EXISTING

LIGHT POLE

EXISTING

NEW

SEE SHEET S-100

PROPOSED DOLPHIN

FACE SOUTH.

EDGE SIDE. SOLAR PANEL SHALL

WITH NEW LIGHT ON DOLPHIN

POWER (SEE DETAIL). INSTALL

NAVIGATION LIGHT WITH SOLAR

PRE-FABRICATED LIGHT PACKAGE

S T

A

.2

PLAN LOCK LIGHTS

A

SECTION

" = 1'-0"4

1SCALE:

MOUNTING FOR LIGHTS

ALUMINUM BULLHORN

EQUAL

ST7 (10FT.) OR APPROVED

TM

ALUMINUM SWIVELPOLE 1

APPROVED EQUAL

PFL84LED OR

ATLAS LIGHTING

APPROVED EQUAL

PFL84LED OR

ATLAS LIGHTING

CONDUIT

EQUAL

OR APPROVED

ST7 (10 FT.)

TM

SWIVELPOLE

ALUMINUM

CONDUIT

ELECTRICAL

B N.T.S.

" = 1'-0"4

1SCALE:

OR APPROVED EQUAL

ATLAS LIGHTING PEL84LED

MOUNTING FOR LIGHTS

ALUMINUM BULLHORN

EQUAL

ST7 (10 FT.) OR APPROVED

TM

ALUMINUM SWIVELPOLE

4" TIMBERS

PILING BRACES

ANGLE IRONS

ALUMINUM

LIGHTING SYSTEM

SECTION - GUIDEWALL

NEW SOUTHWEST GUIDEWALL AND DOLPHINLIGHTING PLAN -

24'-0"

6'-0"

3'-0"

230'-0"

126'-0"

EXISTING LIGHTS.

WILL OPERATE INSYNC WITH

AND BREAKERS. NEW LIGHTS

EXISTING LIGHTING CONTROLS

WILL CONNECT AND UTILIZE

ON NEW GUIDEWALL. LIGHTS

CONDUCTORS IN NEW CONDUIT

CONDUCTORS. RUN NEW

LIGHT CIRCUIT USING EXISTING

TIE-IN AND EXTEND EXISTING

" = 1'-0"4

1SCALE:

3'-0"

S T

A

.1

01A

B E-500

1. Amendment 0001 was issued on Friday afternoon, 06/04/21, and made numerous changes to the specifications including reissuing the entire set of contract drawings. None of the changes made via Amendment 0001 are denoted via highlights or drawing callouts requiring contractors to review everything anew to ascertain the changes. In addition, Amendment 0001 established a prebid site visit for Wednesday, 06/09/21, at 10:00am (two days prior to current bid date). However, the Amendment 0001 states that the proposal due date of Friday, 06/11/21, at 11:00am remains unchanged. We are requesting a minimum of a two-week bid extension to allow a reasonable amount of time for contractors to review/incorporate the Amendment 0001 changes and incorporate site condition information from the scheduled prebid site visit into contractor proposals. The Technical Approach section required by the RFP is highly dependent on the Amendment 0001 clarifications/changes and the existing site conditions that are to be ascertained on 06/09/21.

Due date for proposals is now 1 July 2021.

2. Note 4 on drawing sheet S-103 was added via Amendment 0001 and adds a design requirement for the conceptual formwork design shown in sections A and B requiring the formwork to withstand a direct impact of 1485 Kips. We have several questions regarding this new requirement:

The contractor is responsible if the formwork is damaged. The formwork does not need to withstand 1485 kips as a standalone component, but does needs to be made integral with the other concrete pours.

a. 1485 Kips is a large load. Over what area is the 1485 Kips to be distributed?

The area is determined by the draft of the barge which is on average 7ft

b. What is the direction of the impact load, i.e., normal to dolphin face?

0 degrees, normal to the dolphin nose

c. What is the duration of the impact loading?

The duration is a one time impact due to errant, fully loaded barges

d. Note 4 states that the 1485 Kips applies “when fully integrated into the permanent structure”. Please clarify that the intent of applying the 1485-kip load is after the dolphin is completed.

Yes once the dolphin is completed; barge collisions could occur during construction. The protection plan should address these rare occurrences

e. What is the impact load that the permanent dolphin is designed for?

1485 kips

f. Will USACE provide dolphin design information and calculations to the successful contractor in order to meet this requirement?

No calculations will be provided. The weight of the barges (9000 metric tons) was used to determine the design strength to withstand a direct impact at 0 degrees normal to the nose of the dolphin, as this is the worst case scenario\

3. Detail 1 on drawing sheet S-201 calls for 12 rows of UHMPE rub rails. However, sections A and B on drawing sheet S-504 both show there to be 15 rows of UHMWPE rub rails. Please clarify the correct quantity of rub rail rows.

15 rows of UHMWPE rub rails are shown on S-504 are for the parapet wall sections that coincide with what is shown of S-201. Detail 1 shows 12 rub rails. It should be 15

4. Q&A 13 in Amendment 0001 references points 1 and 6 on drawing C-100 for riprap limits. There are multiple points labeled 1 and 6 on drawing C-100. We have the following questions regarding existing riprap.

a. Please clarify the station limits that contractors should expect to encounter riprap at the site.

In the vicinity of stations 20+00 to 19+74. The exact locations are not known as the rip rap could have shifted over time due to the velocity of the river flow

b. Please provide an estimated thickness/depth of riprap that contractors should expect to encounter at the site for contractors to base their bids on.

The rip rap is 24” thick

c. Does the riprap extend into the area of new 36” pipe pile?

The historical plans do not denote the any rip rap further than stations 20+00 to 19+74.

As previously stated, the rip rap may have shifted over time

5. Q&A 23 in Amendment 0001 states that there are no special order of work requirements for this contract. However, Note 3 on drawing sheet S-103 states that fabrication of concrete formwork cannot begin until all piles are driven. Please clarify if Note 3 is a requirement, or suggestion. If the fabrication of concrete formwork cannot begin until pile driving is complete, this will add a substantial restriction to the work sequence and result in a period of time that the potentially submerged pipe piles are exposed to impacts by vessel traffic.

All piles do not need to be driven, but the piles for that specific portion of formwork must be driven before that concrete formwork is cast.

6. Q&A 28 in Amendment 0001 references the notes on drawings sheets S-300 and S-301. The only mention of composite timber in these notes is Note 1 on drawing sheet S-301 and Note 1 only references 3”x10” diagonals at the mooring bit locations. The majority of the cross-brace materials are not 3”x10”. This is very confusing. We have the following questions regarding which members are polymeric and which members are timber.

a. Are the 3”x12” cross brace members timber or polymeric?

Timber

b. Are the 6”x10” cross brace members timber or polymeric?

Timber

c. Are the 3”x6” cross brace members timber or polymeric?

Timber

d. For clarification, please call out the members on drawing sheet S-300 that are intended to be polymeric.

All members shall be timber except the 12”x12”x20’ girts, 12” x 12” wales and the blocking will be polymeric. The 6”x10”, 3”x12”, 3”x10” Shall be timber along with the walkway as denoted in Specs Section 31 62 19.00 12 paragraph 2.1.

7. Paragraph 4 of specification section 01100 requires the contractor to provide a field office with electricity for the government’s use. Is electricity available to the contractor at the Land Staging Area shown on drawing sheet C-100?

110V minimal shall be available

Q8. Paragraph 1.9, Proposal Submission, of specification section 00130 states that proposals are to be submitted electronically via DOD SAFE and provides a website address. The DOD SAFE web portal requires a request code issued by the recipient in order for users to drop-off files. Please provide instructions for obtaining the required request code for DOD SAFE bid submission and any additional instructions for submitting proposals electronically through the DOD SAFE web portal.

A.8 Please send an email to katherine.b.younts@usace.army.mil requesting a DOD SAFE link for proposal submittal.

Q9. It appears you are requiring the UHMW to be formed, that is going to be quite difficult and expensive. Is this correct or am I mistaken?

A9. Yes, we will need them formed and do the heat bending on the 4” material. We need to make sure we pursue a horizontal pattern as well to abate the possibility of a barge clipping them.

Q10. Can the Government confirm the laydown and staging area? Further, if the laydown and staging area is changed from the current shown on the plans, please provide requirements (who will install ramp access, are temporary fences required, etc).

A10. The laydown and staging area is identified in this amendment (AMD 004). Operations Division will lay rock on the road, and fix the ramp onto the levee, CTR will fix any damage to road or ramp. Fencing for the area is the responsibility of the CTR.

Q11. Can the top of the existing levee be utilized for concrete trucks and other material deliveries?

A11. Heavy equipment greater than HS-20 loading (72,000lbs) is not allowed over the levee or in the batture without an approved stability analysis

Q12. Can the water depth behind the guidewall to be removed be provided?

A12. Not by the Government

Q13. On Sheet S-201, Section B includes the typical rub rail elevation view w/ a 6’-0” dimension provided. Note 1 states that “other varying lengths shall be constructed similarly”. Please confirm that lengths > 6’-0” shall be used w/ 1’-0” bolt spacing and 2 each bolts 6” from the end.

A13. Yes, lengths >= to 6’-0” will follow the same bolting pattern.

Q.14 At the prebid meeting on 06/09/21, alternate landside staging areas for contractor use were discussed. Please clarify the additional staging area location(s) that the contractor will have access to.

A14. Refer to amendment 004 showing the new location. Heavy equipment greater than HS-20 loading (72,000lbs) is not allowed over the levee or in the batture without an approved stability analysis, and no parking/stockpiling within 10 feet of the levee toe.

Q15. At the prebid meeting on 06/09/21, it was noted that there is a 15-ton limit on the Hwy 75 pontoon bridge that is required to be crossed for landside access to the west side of Lock and new SW Dolphin location. For concrete deliveries, will the contractor be allowed to stage concrete trucks and operations on the east side of the Lock?

A15. No, staging will be not be allowed on the east side of the lock. The only way to avoid bridge limits is to truck from Morgan City.

Q16. General Note 7 on drawing sheet G-003 states that all elevations refer to NAVD88 elevation datum, unless noted otherwise. The Hydrographs shown on drawings sheets H-001 and H-002 do not reference a different datum, but we cannot access the historical data via the USACE, Vicksburg, site for these gauges. Please clarify whether the elevations shown for the Hydrographs on drawing sheets H-001 and H-002 are NAVD88 elevations or if these elevations are based on some other elevation datum.

A16. NAVD88

Q17. Amendment 001 added two additional drawings labeled as Plate 3 and Plate 4. These drawings indicate that the elevations shown are based on NGVD datum. Please provide the conversion for the Plate 3 and Plate 4 elevations to convert these elevations to the NAVD88 datum utilized for the construction drawings.

A17. Gage set to NGVD29 (1976)

Adjustment to NAVD88 (OPUS 2010) = -1.21’

Q18. In the Amendment 0001 drawings on sheet C-102, the southwest guidewall is located 260’L of baseline at STA 17+52 and 18+52. In the table titled “Guidewall Offset from Baseline” on C-100, Points 2 and 3 indicate that the guidewall is located 282.38’L of baseline at STA 17+57 and 268.50’L of baseline at STA 18+50. This would affect the size of the floating staging area shown on sheet C-100. Which offset distances should be used for the existing southwest guidewall location?

A18. Refer to amendment 004 for the revised sheets: C-100, C-102, and E-100.

Q19. Paragraph 3.2.1.2 of specification section 31 62 19.00 12, Timber Guidewall Construction, requires fixed leads for batter piles. Fixed leads are not appropriate for floating pile driving rigs as the pile driving rig is floating and subject to movement during pile driving. Please clarify that a fixed stationary pile template will be acceptable in lieu of fixed leads.

A19. Fixed leads may be used as written in the paragraph 3.2.1.2 of spec section 31 62 19.00 12, but swinging leads can be used if the equipment is submitted and approved via the submittal process.

Q20. Drawing sheet S-300 indicates that the timber batter piles are on a 2:1 batter. Based on this batter and the elevations/pile lengths indicated, the pile and pile driving leads will extend over and into the navigation channel during batter pile installation. It appears that the intent of the RFP is to minimize impacts to navigation traffic and to identify all activities that will impact navigation. Please clarify if the 2:1 batter and batter pile length is accurate on drawing S-300.

A20. Yes, the pile batter noted on S-300 is accurate

Q21. Paragraph 3.1.1.1 of specification section 31 62 17.00 12, Steel Pipe Piles, requires full length leads. This is not typical for large diameter pile driving. Please clarify if offshore leads will be allowed in combination with a fixed stationary template system for the pipe pile.

A21. Offshore leads in combination with a fixed stationary template system will be allowable

Q22. At what gage level is navigation prohibited thru the Lock?

A22. 6.9 on landside gauge

Q23. Concrete Note 8 on drawing sheet G-003 states exterior formed surfaces not covered by backfill shall be Class “A” finish and surfaces covered by backfill shall be class “D” finish. Class A surface finish is typically reserved for surfaces prominently exposed to public view where appearance is of special importance. Considering the size, purpose, and mass pour of the concrete dolphin, will a class “D” finish be considered for the concrete dolphin?

A23. Class D can be used for the concrete dolphin

Q24. Note 1 on drawing sheet S-502 requires Grade E, FY=52 ksi material for the pipe piles. Welding procedures are not prequalified for this material and will require significant expense to develop individual welding procedures for tension connector welding. Will Grade D, which has prequalified welding procedures, be acceptable considering Grade D is FY=50 ksi material?

A24. No. Grade E is required as outlined in paragraph 2.1 in specs section 31 62 17.00 12

Q25. Can the aggregate road on top of levee surrounding the Lock be utilized by the contractor?

A25. No

Q26. The conceptual pile hangers shown in sections A and B on drawing sheet S-103 include detailed dimensions, sizes, and layout. Based on past experience, the USACE will not accept pile hangers as shown in section A and B. Please clarify whether the pile hangers detailed on drawing sheet S-103 have the capacity to support the plastic weight of concrete load when pouring the base of the concrete dolphin.

A26. This is a conceptual drawing. It is the CTR’s responsibility to design the hanger system to support the plastic weight of concrete.

Q27. Note 4 on sheet S-300 states that the face of Wales is permitted to be +/- inches off the Lock Chamber face. Please provide the +/- tolerance for Wales relative to the Lock Chamber face.

A27. Coordinate with the Project Engineer or on-site QAR for final tolerance, but Positive tolerance could rip off the timbers if navigational traffic going the opposite way. If offset, the CTR really needs to taper the walers. Zero negative tolerance, 1” positive (into the channel) and the walers would need to be tapered to be flush with concrete.