C-604_W91P6-17-B-0008_GSD_Lake_Street_Plans_revisedAMD.pdf

PDF 65 KB Posted

Attached to
Lake Street Sanitary and Storm Sewer Improvements Section 219, Gary, Lake County, Indiana
Solicitation number
W912P617B0008
Issued by

About this file

This File Contains the Revised Drawing Sheet "C-604" and is a part of Amendment 0002

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S O

L I C

I T

A T

I O

N

N

O

D E

S I G

N E

D

B

Y

D E

S C

R I P

T I O

N

M A

R K

S I Z

E

S U

B M

I T

T E

D

B

Y

D A

T E

C O

N T

R A

C T

N

C H

E C

K E

D

B

Y

D R

A W

N

B

Y

I S

S U

E

D

A T

E

SHEET ID

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

US Army Corps of Engineers

U S

A

R M

Y

C

O R

P

F

E

N G

I N

E E

R S

A M

E R

I C

A

R

U C

T U

R E

P

I N

T

I N

C

S

H A

D E

L A

D

A

T I O

N

I N

D I A

N A

P O

L I S

I N

D I A

C H

I C

A G

O

D

I S

T R

I C

T

C H

I C

A G

O

I L L I N

O I S

A N

S I

D

W P

B

G A

Y

N

I T

A R

Y

D

I S

T R

I C

T

L A

K

R

E E

T

S

A N

I T

A R

Y

A

D

O

M

W

I M

P R

O V

E M

E N

T S

BID SET

PLOT SCALE: 1:3.560209 EDIT DATE: 6/22/17 - 7:31 PM EDITED BY: JGRIFFITH DRAWING FILE: P:\2017\00695\D. DRAWINGS\ENVIRONMENTAL\C-604 - SAN-TBL.DWG

STATE OF

PE60860328

J C

M

M J G

K M

B

C L F

S A

N I T

A R

Y

S

E W

H

A B

I L I T

A T

I O

N

T

A B

L E

S

C-604

A1

SANITARY MANHOLE REHABILITATION TABLE

A5

SANITARY PIPE REHABILITATION TABLE

NOT IN CONTRACT

STRUCTURE ID RIM INVERT

MH DEPTH (FT) MH DIAMETER (FT)

REHAB METHOD UNIT QTY

29 607.2 593.6 13.55 4

Non-structural Lining.

SF 170

586 - - - 4

Raise casting to grade

EA 1

588 605.5 587.55 17.99 4

Structural Lining.

SF 226

Replace steps.

EA 18

675 606.4 587.5 18.89 4

Replace steps.

EA 19

676 - - - 4

Raise casting to grade

EA 1

677 603.7 592.2 11.46 4

Non-structural Lining.

SF 144

678 601.8 592.45 9.3 4

Non-structural Lining.

SF 117

688 605.7 587.15 18.58 4

Structural Lining.

SF 233

Replace steps.

EA 19

694 605.7 591.5 14.2 4

Non-structural Lining.

SF 178

Replace steps.

EA 14

Raise casting to grade

EA 1

695 605.7 593.4 12.26 4

Structural Lining.

SF 154

Replace steps.

EA 12

696 602.5 593.95 8.53 4

Structural Lining.

SF 107

Replace steps.

EA 9

701 604.3 594.48 9.85 4

Non-structural Lining.

SF 124

Replace steps.

EA 10

702 607.2 595.03 12.19 4

Structural Lining.

SF 153

Replace steps.

EA 12

707 608.5 595.57 12.91 4

Structural Lining.

SF 162

Replace steps.

EA 13

708 608.1 596 12.08 4

Non-structural Lining.

SF 152

Replace steps.

EA 12

709 608 596.1 11.87 4

Replace steps.

EA 12

710 608.4 596.47 11.92 4

Replace steps.

EA 12

711 609.5 597.1 12.4 4

Non-structural Lining.

SF 156

712 610.2 597.56 12.62 4

Replace steps.

EA 13

713 614.1 600.5 13.57 4

Replace steps.

EA 14

715 613.6 605.5 8.12 4

Structural Lining.

SF 102

Heavy clean.

SF 102

Chemical grout.

SF 102

UPSTREAM MH DOWNSTREAM MH MATERIAL

DIAMETER (in)

STATION START STATION END DESCRIPTION QTY UNIT

DESIGN REQUIREMENTS

(ASTM F1216)

MINIMUM LOADING

REQUIREMENTS

588 585 RCP 54 - -

non-structural liner 468 LFT - -heavy cleaning

468 LFT - -

675 688 RCP 54 - - non-structural liner 340 LFT - -

686 587 RCP 36 0+20 0+50

point repair

30 LFT - -

688 588 RCP 54 - -

structural liner 170 LFT

FULLY DETERIORATED

GRAVITY PIPE CONDITION

RAILROAD LOADING

heavy cleaning

170 LFT - -

694 688 VCP 24 - -

chemical grout

180 LFT - -

702 701 VCP 18 - - CIPP 175 LFT

FULLY DETERIORATED

GRAVITY PIPE CONDITION

HS-20 HIGHWAY LOADING

676 675 VCP 24 - -

chemical grout

145 LFT - -

678 677 VCP 24 - -

chemical grout

150 LFT - -

707 702 VCP 15 - - CIPP 180 LFT

FULLY DETERIORATED

GRAVITY PIPE CONDITION

HS-20 HIGHWAY LOADING

708 707 VCP 15 - - CIPP 140 LFT

FULLY DETERIORATED

GRAVITY PIPE CONDITION

HS-20 HIGHWAY LOADING

636 637 VCP 12 - -

chemical grout

75 LFT - -

638 637 VCP 12

chemical grout

98 LFT - -

0+03 0+18 point repair

15 LFT - -

637 685 VCP 12

chemical grout

100 LFT - -

0+10 0+30 point repair

20 LFT - -

680 679 VCP 15

chemical grout

160 LFT - -

1+40 1+60 point repair

20 LFT - -

682 681 VCP 15 - - CIPP 125 LFT

FULLY DETERIORATED

GRAVITY PIPE CONDITION

HS-20 HIGHWAY LOADING

683 682 VCP 12 - -

chemical grout

150 LFT - -

710 709 VCP 12 - -

chemical grout

180 LFT - -

711 710 VCP 12 - -

chemical grout

160 LFT - -

713 712 VCP 12 - -

chemical grout

160 LFT - -

696 695 VCP 24 - -

chemical grout

160 LFT - -

695 694 VCP 24 - -

chemical grout

50 LFT - -

697 696 VCP 18 - -

chemical grout

190 LFT - -

709 708 VCP 15 - -

chemical grout

35 LFT - -

712 711 VCP 12 - -

chemical grout

170 LFT - -

677 676 VCP 24 - -

chemical grout

165 LFT - -

679 678 VCP 15 - -

chemical grout

130 LFT - -

681 680 VCP 15 - -

chemical grout

150 LFT - -

684 683 VCP 12 - -

chemical grout

165 LFT - -

685 684 VCP 12 - -

chemical grout

130 LFT - -

NOT IN CONTRACT

NOT IN CONTRACT

NOT IN CONTRACT

File details come from the government source that posted it. Updated .