Revised Reference Sheet_12-MAY-2023.pdf
PDF 2 MB Posted
- Attached to
- J. PERCY PRIEST RESTRICTED AREA INSTALLATION Federal contract opportunity
- Solicitation number
- W912P523Q0027
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Foreign National Site Visit Request Form.pdf | ||
| KO Determination Limiting Competition- JPP Security Fence_Redacted.pdf | ||
| W912P523Q0027 Solicitation- JPP Security Fence Installation.pdf | ||
| US Citizen Site Visit Request Form.pdf | ||
| TSpecs_JPP Restricted Area Fence Installation_RTA_30-MAY-2023.pdf | ||
| TPlans_JPP Restricted Area Fence Installation_RTA_18-APR-2023.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
FOR INFORMATION ONLY
Weight and length limit:
Move gates up to 1,500 lbs and 40 ft
Reliable:
Battery backup provides up to 4,000 ft of travel. Upgrade batteries for up to 25,000 ft
Programmable:
Over 70 user configurable settings to meet site specific requirements.
Connected:
Optional HyNet™ enables real-time system security alerts
Features:
SlideSmart™ DC Dependable slide gate operator with battery backup Chain drive slide gate operator that’s easy on gate hardware with features like soft start and stop, adjustable speeds, and adaptive obstruction detection.
Excellent for solar applications.
Battery:
Monitor battery conditions and maximize life with the intelligent charging system
Diagnostics:
Easy system troubleshooting with onboard event log
Adjustable:
Independent, field-adjustable open and close speeds
Made in USA:
Designed, tested and built with global materials
1.5K
Model SlideSmart DC 10F SlideSmart DC 15
Solar SlideSmart DCS 10F SlideSmart DCS 15
Gate Weight Max. 1,000 lb (453 kg) 1,500 lb (680 kg)
Gate Length Max. 40 ft (12 m)
Pull Force 200 lb (90.7 kg) 300 lb (136 kg)
Rate of Travel 1.75, 2 or 2.25 ft/s (53, 61 or 69 cm/s) Open/Close speed set independently
0.75, 1 or 1.25 ft/s (23, 30 or 38 cm/s)* Open/Close speed set independently
Duty Cycle Continuous
Horsepower 1/2 hp
Drive Electromechanical
UPS Battery Backup Cycles†
Field configurable to fail open or secure when batteries deplete.
Standard battery backup gate travel: Two 8Ah batteries. Up to 4,000 ft (1,219 m) after AC power loss.
Extended battery backup gate travel: Two 50Ah batteries. Up to 25,000 ft (7,620 m) after AC power loss.
Temperature Rating -13ºF to 158ºF (-25ºC to 70ºC)
Operating Voltage 24VDC
Input Voltage 115V or 208-230V, 60/50 Hz. Solar: 24VDC solar panels**
Accessory Power 12VDC and 24VDC 1A each
Included Accessories 30 ft (9 m) of #40 corrosion resistant roller chain, two steel gate mounting brackets, one premium EMX IRB-MON photo eye, one 5-foot premium ASO edge sensor and a pre-wired Hy2NC adapter
Communication USB, RS-232, RS-485. Ethernet/fiber using optional HyNet™ Gateway accessory
User Controls Smart DC Controller with 70+ configurable settings. 32 character LCD display and 5 tact buttons or a PC using S.T.A.R.T.
software.
Relays Two configurable user relays: 30VDC, 3A solid state and 250VAC, 10A electromechanical; Optional Hy8Relay™ for 8 additional relay outputs
Finish Zinc plated chassis; molded polyethylene cover
ETL Listed (UL 325) Usage Class III, IV*** Usage Class I, II, III, IV*
Cycle Tested 500,000 cycles
Warranty 5 year w/product registration 5 year (7 year single-family residential) w/product registration
| * | Speed | setting | cannot | be | configured | to | exceed | 1 | ft/s | for | Usage | Class | I | and | II. | |||||||||||
| ** | The | actual | number | of | gate | cycles | available | from | battery | depends | upon | gate | resistance | to | travel, | cycle | length, | battery | size, | state | of | charge | and | health, | ambient | temperature, |
| accessory | power | draw | and | frequency | of | gate | cycles | during | power | outage. | ||||||||||||||||
| *** | Not | for | residential | use | or | applications | intended | to | serve | the | general | public. |
Optional Accessories - See website for complete list
SlideSmart DC Residential and Commercial Applications
Contact Nice | HySecurity for an operator/parts distributor near you.
phone 253-867-3700 | 800-321-9947 hysecurity.com | sales@hysecurity.com D0593 121820
Technical Specifications SmartDC powered by
Post Mount KitBase Extension
ASO Edge SensorsBattery Backup Kit - 50Ah
Photo Eye KitsHyNet™ Gateway Integration
Hy5B Vehicle Detector
Rodent Barrier - 10F, 15 models
1815-064-K-3-17
Wiegand Keypad Installation and Programming
These instructions apply to the following DoorKing Digital Keypads: 1815-051, 1815-052, 1815-059, 1838-120, 1504-120 with circuit board P/N 1515-009.
When used to control entry through an automated vehicular gate system, the keypad must be mounted a minimum of 6-feet away from the gate and gate operator, or mounted in such a way that the person using the keypad cannot come into contact with the gate or gate operator.
These keypads output their data in a 26-bit wiegand format and must be connected to an access controller such as the DKS models 1833, 1835, 1837 or 1838.
WIRING
Term 1 Input power 12-24 volt AC or DC NEGATIVE / WIEGAND COMMON (BLACK) Term 2 Input power 12-24 volt AC or DC POSITIVE (RED) Term 3 Earth Ground Term 4 Wiegand COMMON Term 5 Not Used Term 6 Wiegand DATA 0 (GREEN) Term 7 Wiegand DATA 1 (WHITE) Term 8 Not Used
1 2 3 4 5 6 7 8
LED Lights
LED lights are applicable to REV D or lower boards.
REV E and higher boards have a lighted keypad.
Orange
Gray 12-24 Volt AC or DC
White – DATA 1
Black - COMMON
Green – DATA 0
Red - POWER To Access Controller
MASTER CODE
1515-009
1815-064-K-3-17
PROGRAMMING
MASTER CODE
1. Press the master code button on the circuit board once.
2. Enter a four-digit code _ _ _ _ then press * (beep).
FACILITY CODE
1. Press * 4 and the four-digit master code _ _ _ _ (beep).
2. Enter a three-digit facility code _ _ _ (000-255) then press * (beep).
3. Press 0 # together to end the programming (beeeeeep).
4. NOTE: If facility codes are not used, skip this step.
ENTRY CODE BOUNDARIES
Entry codes between the boundary limits will weigand out to the controller. Entry codes outside the boundary limits will not weigand out. Set the boundary limits so that the entry codes do not duplicate any card or transmitter codes that are programmed into the controller. For example, if transmitter codes 01000 through 02000, and card codes 06000 through07000 are already being used and programmed into the access controller, you could set the lower boundary to 03000 and the upper boundary to 05000. This prevents a five-digit entry code from accidentally duplicating a card or transmitter code.
FIVE DIGIT BOUNDARIES
1. Press * 5 and enter the four-digit master code _ _ _ _ (beep).
2. Enter a five-digit lower boundary _ _ _ _ _ then press * (beep).
3. Enter a five-digit upper boundary _ _ _ _ _ then press * (beep).
(To remove five-digit boundaries, enter 0 0 0 0 0 in step 2, and 65405 in step 3.)
4. Press 0 # together to end the programming (beeeeeep).
Four digit entry code note The keypad will respond to four-digit entry codes if they are entered on the wiegand keypad with the # key being pressed first (which is normal for four-digit entry codes). For example, the tenant presses “#-1-2-3-4” (or whatever the 4-digit code is). The # automatically defaults to “0”, so if “#-1-2-3-4” is entered on the keypad, the 5-digit code “0-1-2-3-4” is sent to the controller.
The door/gate will open provided that the 5-digit weigand code “0-1-2-3-4” is programmed as a device code.
ANDRIOD SMARTPHONE APPS – Free download at Google Play Store (Can be used with the 1815-059 keypad only)
DKS Smart Open App – allows users to use their Android smartphone to activate the digital lock.