W912P521B0020-0001.pdf
PDF 279 KB Posted
- Attached to
- Watts Bar Lock - Armor Wall Painting Federal contract opportunity
- Solicitation number
- W912P521B0020
About this file
This document contains an amendment to a solicitation for a firm fixed price construction contract and related questions and answers. The U.S. Army Corps of Engineers Nashville District is seeking to paint the wall armor at Watts Bar Lock in Decatur, Tennessee for an estimated value between $500,000 and $1,000,000. A pre-bid site visit was held on August 18, 2021, and bids are due by September 13, 2021 at 10:00 AM Central Time. The selected contractor will be required to wash, spot clean, and overcoat the existing armor walls in accordance with the amended technical specifications, using a coating system compatible with the existing topcoat as approved by the Contracting Officer Representative. Work must be performed Monday through Thursday from 7:00 AM to 5:00 PM Central Time.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| OF 1419a - Bid Abstract - W912P521B0020.pdf | ||
| OF 1419 - Bid Abstract - W912P521B0020.pdf | ||
| Pre-Bid Site Visite Sign In.pdf | ||
| Foreign National Security Form.pdf | ||
| US Citizen Security Form.pdf | ||
| W912P521B0020 - WBL - Armor Wall Painting.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
PROJECT: Watts Bar Lock Armor Wall Painting
PURPOSE: The purpose of this amendment is to:
a.) Publish the questions and answ ers resulting from the site visit;
b.) Publish amended Technical Specif ications;
c.) Publish the sign-in sheet from the site visit.
d.) All other terms and conditions remain unchanged.
FAR 52.252-3, Alterations in Solicitation, is updated accordingly.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 4
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 30-Aug-2021
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912P521B0020
X 9B. DATED (SEE ITEM 11)
12-Aug-2021
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
30-Aug-2021
CODE
CONTRACTING DIVISION (SDH)
110 9TH AVE S, ROOM A680
NASHVILLE TN 37023
W912P5 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
X 1
W912P521B0020
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
The following have been added by full text:
Technical Questions & Answers for W912P521B0020 Watts Bar Lock – Armor Wall Painting
1. Will the USACE be providing lead sample results as noted in 01 11 00, 1.1.5?
Answer: Yes. See Amendment 0001, which incorporates the Report of Lead Paint Measurements as a reference.
2. Section 02 83 00, it discusses containment. This section requires exhaust and negative air as part of the containment. Is this type of containment required since the scope of work is washing, spot cleaning, and overcoating?
Answer: See Amendment 0001. The specifications concerning the negative air containment requirements have been amended to allow use of local exhaust ventilations systems (LES) when/if the contractor means and methods require.
3. Is the contractor allowed to utilize USACE’s barge that is currently on site if we supply a competent operator?
Answer: No.
4. Section 01 11 00, 1.1.3 – Lock Outages, Pg. 4 states “Lock outages will be scheduled by the COR to provide the Contractor a reasonable amount of time to clean, surface prep, removal of existing loose lead-based paint system, paint and allow paint to cure for the items listed above.” Can the USACE define a reasonable amount of time in hours per day for lock outages for the contractor to perform the work?
Answer: USACE will provide daytime lock closures during contractor work hours (Monday- Thursday from 7:00am – 5:00pm).
5. Section 02 83 00, 1.3.5 – Competent Persons, Pg. 5 currently requires a CIH, CSP or licensed lead-based paint abatement supervisor/project designer in the State of Tennessee. Because the scope of this work is industrial, the supervisor/project designer certification does not apply as this certification is focused on child-occupied facilities.
The industry accepted lead paint removal competent person certificate (C-3) is provided by the SSPC – the same organization that issue the SSPC QP1 and QP2 certificates that USACE specifies on all of its painting projects. Will the USACE accept the SSPC’s 32-hour course Supervisor/Competent Person for Deleading of Industrial Structures (C-3) course instead of the supervisor/project designer certification?
Answer: Yes. USACE will accept the SSPC’s 32-hour C-3 certification.
6. Section 09 97 02, 3.5 – Painting Schedule, Pg. 11 indicates the chamber rub rail must be coated. There is no pay item associated with this work, is the painting of the chamber rub rail required?
Answer: No. See Amendment 0001. The specifications were revised to remove the chamber rub rails from the painting schedule.
7. There were conversations of the coating system not being compatible with the current specified coating system.
Does the Corps have an answer on the desired painting system for this project?
Answer: Based on the information available to the Government, the existing topcoat is Keeler & Long KLF10092, Kolor-Sil Gloss Enamel. After award, the contactor will be required to demonstrate to the Contracting Officer Representative (COR) that the proposed coating system is compatible with the existing wall coating thru compatibility and pull tests. The COR’s approval of the painting system is required before painting begins
8. Will the USACE consider pushing the bid date to the end of next week to allow ample time for bid submission?
Answer: Bids are due 13 September 2021 by 10:00am Central Time.
9. What are the allowable work days and hours?
Answer: Monday – Thursday from 7:00am – 5:00pm Central Time.
10. What will the protocol be for unforeseen de-mobilization during workdays/hours for emergencies?
Answer: In the unlikely event requiring the contractor to de-mobilize for an emergency , the contractor will be notified by the Contracting Officer and provided sufficient time to take action to prevent loss of time and materials.
11. Can the Project Superintendent act as the SSHO and/or QCM for this project?
Answer: See Amendment 0001. Specification Section 01 35 26, 1.7.1.1.1 was revised. The Project Superintendent may act as both the Project Superintendent and SSHO. The QCM may act as both the QCM and the SSHO. However, the Project Superintendent can NOT serve the QCM, as those interests can conflict.
SECTION 00 21 00 - INSTRUCTIONS
The following have been modified:
52.252-3 ALTERATIONS IN SOLICITATION (APR 1984)
Portions of this solicitation are altered as follows:
Amendment P00001:
PROJECT: Watts Bar Lock Armor Wall Painting PURPOSE: The purpose of this amendment is to:
a.) Publish the questions from industry and the answers from the Government.
b.) Publish amended Technical Specifications.
c.) Publish the sign-in sheet from the site visit.
d.) All other terms and conditions remain unchanged.
(End of Summary of Changes)