Verify current revision of this document in WorldView prior to use.

����
����������������������������&��
*#�������
���� "��������� ���� ������� ������ ����
������ ������
������ ������������&�����
�������
�����������
����������������� ���
����������������

1. SCOPE

1.1 Scope. The purpose of this specification is to provide methods of directly marking wire/cable, or indirectly marking using marker sleeves and heat shrinkable sleeving, and the specific requirements needed for performance of marking. Variations of wire and cable are as follows : insulated single conductor wire, shielded–jacketed single and multi–conductor cable, jacketed multi–conductor cable, shielded cable, unjack-eted cable, twinax cable, triax cable, coax cable, and fiber optic cable. The preferred methods of marking to be used at Sikorsky aircraft in order of precedence are: Laser, Ink jet, Sleeve markers, Sleeving (wrap around and heat shrinkable). SS8798 calls out this specification for marking of wire and cable.

NOTE: Hot impression stamping of wire/cable is not a recommended method for marking wire and cable. It shall only be used as an exception with the approval of Sikorsky Aircraft and shall meet all the requirements of SS7334.

2. APPLICABLE DOCUMENTS

2.1 The following documents form a part of this specification to the extent specified here-

in. Unless otherwise indicated, the issue specified in the applicable Sikorsky Aircraft Index of Material and Process Specifications shall apply.

STANDARDS

Sikorsky Aircraft SS7072 Insulating, Sleeving, Heat–Shrink Federal C–F–206 Felt Sheet: Cloth, Felt, Wool, Pressed (Type I, Class 9R4)

SPECIFICATIONS

Sikorsky Aircraft SS7094 Sleeve Markers, Electrical Harness, Wire & Cable SS7095 Identification Marker, Tie–on SS7194 Sleeve Markers, Electrical Harness, Wire & Cable SS8798 Identification Marking of Parts Methods for Military MIL–H–5606 Hydraulic Fluid, Petroleum Base: Aircraft: Missile and Ord-nance MIL–PRF–5624 Turbine Fuel, Aviation, Grades JP–4, JP–5 and JP–5/JP–8

ST

MIL–PRF–7808 Lubricating Oil, Aircraft Turbine Engine, Synthetic Base MIL–E–9500 Ethylene Glycol MIL–PRF–23699 Lubricating Oil, Aircraft Turbine Engine, Synthetic Base MIL–C–55330 Packaging MIL–H–83282 Hydraulic Fluid, Fire Resistant, Synthetic Hydrocarbon Base, Air-craft TT–I–735 Isopropyl Alcohol Other ASTM G 21 Recommended Practice for Determining Resistance of Syn-thetic Polymeric Materials to Fungi

ASTM E 1119 Ethylene Glycol

SAE AS–1241 Hydraulic Fluid

Distribution C: Distribution authorized to U.S. Government Agencies and their contractors only, for administrative or operational use, as of 28 April 2000. Other requests shall be referred to the Utility Helicopters Project Management Office at:

United States Army Aviation and Missile Command Sparkman Center, Building 5308, 4th Floor

SFAE-AV-UH

Redstone Arsenal, AL 35898-5000

WARNING – This document contains technical data whose export is restricted by the Arms Export Control Act (Title 22, U.S.C., Sec 2751, et. seq.) or the Export Administration Act of 1979, as amended, Title 50, U.S.C., App. 2401 et. seq.

Violations of these export laws are subject to severe criminal penalties. Disseminate in accordance with provisions of DoD Directive 5230.25.

Delivered Under Contract DAAH23-02-C-0006 By Sikorsky Aircraft Corporation.

3.0 REQUIREMENTS

Note: CO2 type laser (YAG) marking Shall Only be used in accordance with para 3.2.1.1 for any wire/cable marked at or for Sikorsky aircraft.

3.1 PERSONNEL – Only experienced personnel (personnel who have satisfactorily demonstrated a level of proficiency determined by manufacturing shop supervision), or personnel under the guid-ance of an experienced operator may accomplish identification of electrical wiring.

3.2 MATERIALS AND EQUIPMENT. Are listed in order of precedence for wire and cable marked at Sikorsky Aircraft. Sikorsky Aircraft and Suppliers shall follow the order of precedence unless specific marking is required by contract or purchase order. Sikorsky Aircraft and suppliers shall meet the individual requirements for each marking that is applicable, in accordance with this specifi-cation. Variations for the equipment as stated in this specification are acceptable for use by suppli-ers as long as all other requirements in this specification are met. All equipment shall have a regular maintenance schedule to assure correct and efficient operation.

The types of markings described as follows are either directly marked on the wire/cable insulation (laser, ink jet, (see SS7334 hot impression stamp) or directly placed on the wire/cable insulation (sleeve markers, wraparound and heat shrinkable insulation sleeving) and they have been directly marked. Recommendation: All direct methods of marking should coordinate wire lengths with wire/ cable spool lengths to assure minimum waste (i.e. short lengths with spool short lengths). An in– line spark tester or similar device is needed to pick up splice locations on each spool.

3.2.1 Laser Marking . A high energy excimer style laser is the preferred type laser to be used on any wire and cable marked at or for Sikorsky Aircraft. The unit comprises a Xenon Chloride excimer laser with beam delivery system, incorporating a simple character generating mask changer, providing high speed automatic changes of code, coupled to a precision cable handling system. Wave length (308nm). The whole system is automated and controlled by an IBM compatible PC. The system employs a non aggressive ultraviolet laser marking to produce a permanent, high quality, high defi-nition cable identification mark while processing cable at high speeds. It is used for marking wire or cable with a primary insulation tape wrap and /or dispersion coating or solid extruded insulation.

It shall be capable of marking wire/cable from 26 ga to 1/4 inch outside diameter. Uses a laser energy density of 1 joule/cm2 for marking. Water cooling – closed loop chiller supplied.

Caution: Xenon Chloride – Gas needs to be changed approximately every 3 months depending on usage. Gas bottle exchange shall require gloves, light suit, face shield and filter mask. Hazard of the gas is within a 2 foot area of the bottle. Proper precautions shall be followed at all times.

Water used to cool the system becomes contaminated/hazardous and shall be disposed of using proper Environmental protection procedures to dispose of it.

3.2.1.1 Yag Laser Marking. A Yag Laser shall only be used IF it has been modified with filters or reducers that convert the laser output from the infrared spectrum down to the ultra violet(UV) spectrum. This will assure that the laser will mark the wire/cable comparable to the excimer laser. Manufacture’s specific instructions and precautions shall be followed to assure that the system will not damage the wire/cable for correct operator interface. Under no circumstance shall the operating system be a discomfort or generate an unsafe or hazardous condition for the operator.

3.2.2 Ink Jet Marking. Shall be capable of marking wire/cable from 24 gage to 1/4 in outside dia. wire size.

3.2.2.1 UV cure – Shall be Autoprint, 350 Mark III UV Ink jet Marking System with Autotreat, and Auto-cure, stations. It shall have in line post print curing, with a maximum machine speed of 200 feet per minute. Lamp lengths from 100mm to 1655mm and outputs from 60W/cm to 180W/cm. Ink jet machine printing velocity shall not exceed 80 ft per minute when using UV cure ink.

3.2.2.1.1 Ink – White UV ink (P/N WT1106) , Viscosity of 3.5cps, 4000 wash, 1120 make up. PF Domino.

Caution: Ink is

Toxic by inhalation and if swallowed May cause sensitization by skin contact Highly Flammable Caution: Wash is Irritating to eyes and respiratory system Flammable Liquid

Harmful if swallowed Absorbed through skin Vapors are heavier than air

Caution: Make Up is Irritating to eyes and respiratory system Flammable Liquid

Toxic if swallowed Toxic if inhaled Absorbed through skin Vapors are heavier than air

3.2.3 Sleeve Markers. Size and installation shall be in accordance with the applicable sleeve marker specification as defined in this paragraph. Coax, twinax, and triax cable see SS8796. Unless other-wise specified unjacketed twisted cable shall be identified with TMS sleeves per SS7094 and SS7194. Tie on sleeves see SS7095. Each sleeve marker shall be marked in accordance with the marking requirements of each sleeve markers individual specification. These requirements are the responsibility of Sikorsky and the individual supplier to assure the marking is acceptable on every sleeve that is marked.

3.2.4 Wraparound Sleeves – A integral clear polyester or polyimide tape shall protect and secure a white synthetic label. Sleeves shall be applied using a Getting advance legend entry labeling system #10000. The label shall be a 2“ marking tape capable of 22 characters per line. Diameter range of three different cartridges for applying the sleeves are; 1/8 to 5/16(P/N 1800–2.0), 1/4 to 9/16 (P/N 1850–2.0) and 1/2 to 1 inch (P/N 1950–2.0).

3.2.5 Heat Shrinkable Insulation Sleeving. When specified on the engineering drawing heat–shrinkable sleeves in accordance with SS7072 shall be used for marking. Different sizes are available depend-ing on application. Each sleeve shall be placed on the wire/cable in the locations as identified on the engineering drawing and with the specified marking. They shall be shrunk unless otherwise specified. The size, selection, and shrinking shall be in accordance with the applicable paragraphs in SS7071. Note: if the shrink sleeving is marked using hot stamp marking, each lot/job that is marked shall be tested in accordance with SS7334.

3.2.6 Hot Impression Stamping. Shall be in accordance with SS7334.

3.3 COLOR, IDENTIFICATION, AND SPACING BETWEEN MARKINGS.

3.3.1 Color. Each marking system shall use a contrasting color on the wire/cable or sleeve marker or heat shrinkable sleeving it is marking.

3.3.1.1 Laser (Excimer/Yag) – Brown to gray to blue/black depending on the amount of TiO2 in insulation jacket .

3.3.1.2 Ink Jet – White ink (preferred for colored wire/cable at Sikorsky) or black ink or magenta (for other suppliers).

3.3.1.3 Sleeve and Shrink –White or black sleeve (using contrasting ink) – see each individual specification.

3.3.1.4 Wraparound Sleeves – White only (Black ink on white sleeves with clear tape).

3.3.2 MARKING CHARACTERISTICS.

3.3.2.1 Laser (Excimer/Yag) – The system shall be capable of producing full alpha–numeric character set, plus: – . /. Three standard print sizes, horizontal and vertical print orientation, and continuous mark spacing programmable in the range 3 inches to 39 inches(75mm to 1000mm). Print sizes are as follows:

Large Print (Horizontal) 1.60 X 1.20mm (0.06 X 0.047 inch) Medium Print (Horizontal) 1.09 X 0.84mm (0.043 X 0.033 inch) Small Print (Vertical) 0.99 X 0.74mm (0.39 X0.29 inch).

3.3.2.2 Ink Jet – The system shall be capable of producing full alpha–numeric character set, plus: – . /.

Three standard print sizes, horizontal and vertical print orientation, and continuous mark spacing programmable in the range 3 inches to 39 inches(75mm to 1000mm).

3.3.2.3 Sleeve Markers – All sleeves shall meet the individual applicable specifications for characters per SS7094, SS7095 or SS7194.

3.3.2.4 Sleeves (wraparound)– The system shall be capable of producing full alpha–numeric character set, plus: – . /. Three standard print sizes, horizontal and vertical print orientation, and continuous mark spacing programmable in the range 3 inches to 39 inches(75mm to 1000mm).

3.3.2.5 Sleeves (Shrinkable) – SS7072A (type RNF) heat shrink may be identified using any of the marking methods as defined in this specification except wraparound. The print sizes and spacing shall be in accordance with the applicable marking characteristics defined above.

3.4 MARKING PROPERTIES.

3.4.1 Laser Marking (Excimer/Yag) – Shall be used on any insulation color except black in which suffi-cient contrast and other performance requirements of this specification can be achieved. Wire or cable shall provide a minimum marking contrast of at least 60% on white insulation and all other colors. Best results in laser marking shall be obtained when Rutile–based titanium dioxide (TiO2) pigments are used in the wire/cable insulation. Percent of contrast shall be measured with a Spec-trum Technologies CMS2 contrast measuring system in accordance with the manufacturer’s in-struction to provide consistent results.

3.4.2 Ink jet Marking. – Shall be used on black insulation. Other insulation colors may be marked with this process as long as the proper contrasting ink is used and the applicable performance require-ments of this specification are met. Most of the black insulation is radiated crosslinked ETFE.

3.4.3 Sleeve Markers – Shall be used on all types of wires and cables as applicable. Shall meet all individ-ual specifications as applicable. SS7094, 7095 and 7194.

3.4.4 Heat Shrink – Shall be used on all wires and cables as applicable and meet SS7072 requirements for correct configurations. Performance requirements shall be met per applicable marking method.

3.4.5 Wraparound sleeves – Shall be black ink on white sleeves meeting applicable performance require-ments per this specification.

3.4.6 Hot Impression Stamping – Shall only be used as a last alternative on any wire and cable insulation.

May be used on sleeve markers and heat shrinkable sleeving meeting the performance require-ments of the applicable method used per this specification or the individual specification.

3.5 PERFORMANCE REQUIREMENTS. All performance requirements described in this section shall be done for initial qualification and inspection per section 4.3. Acceptance inspection required per section 4.4.

3.5.1 DEPTH – LASER ONLY (Excimer/Yag)– Shall be tested per para 4.6.5 to assure laser mark pene-trated typically into the outer coating or jacket of the wire per figure1.

Center conductor

Insulation

Insulation

Depth of Marking

10 to 25 μm (0.0004 to 0.001 in.)

depending on laser and TiO2�!"

Acceptable Range –

FIGURE 1

3.5.2 CONTRAST – LASER ONLY (Excimer/Yag)– Shall be tested per para 4.6.5. Wire/Cable shall pro-vide a marking contrast of greater than 60% per paragraph 3.4.1.

3.5.3 LEGIBILITY (ALL) – Wire/cable shall be viewed from a distance of 12 to 14 inches (without addition-al magnification other than corrective lenses), in ambient light not less than 30 foot candles. Legibil-ity of all markings shall conform to the workmanship requirement of 3.5.6.

3.5.4 TEMPERATURE & FUNGUS (ALL) – Wire/cable markings shall be cycled once thru the minimum and maximum temperature requirements of the substrate that it is marked on in accordance with para 4.6.6. They shall not support fungus growth when tested per para 4.6.7. After the temperature test, all markings shall meet legibility requirements per para 3.5.3.

3.5.5 ADHERENCE – Wire/cable markings shall meet the requirements of para. 3.5.3 and 3.5.6, after separate test specimens have been subjected to the adherence test of para 4.6.2 and solvent re-sistance test of para 4.6.3.

3.5.6 WORKMANSHIP (ALL) – All marking shall meet the performance and marking requirements de-scribed herein. Marks shall be sharp–edged, aligned, and centered on the wire/cable surface when viewed without magnification. Markings that are not uniform, not complete, bleeding, smudging, and faint shall be adequate basis for rejection when characters from adjacent marks cannot be deci-phered sufficiently to understand each string of characters. Insulation damage consists of cut, peeled, cracked, pierced, wrinkled, split, scorched or gouged Insulation damage that degrades the physical and electrical properties of the wire/cable shall be adequate basis for rejection. In no case shall the marking method cut through the insulation material exposing the shield or center conduc-tor of the wire/cable. Wire/cable shall be tested in accordance with para 4.6.8 (insulation damage) for both qualification and acceptance to assure not cutting the insulation. Per para 4.6.5 (depth only, at initial qualification) shall be tested to assure the marking methods are acquiring proper depth to assure reliability. Any of the methods used that create any type of insulation damage is cause for rejection and requalification.

4.0 QUALITY ASSURANCE PROVISIONS.

4.1 Responsibility for Inspection– Unless otherwise specified in the contract or purchase order, the con-tractor is responsible for the performance of all inspection/tests requirements specified herein. The contractor may use his facility or any other facility suitable for the performance of all Qualification inspections. Acceptance inspections/tests shall be performed at the contractors facility. Sikorsky Aircraft shall approve the contractors process before the contractor is eligible to process wire/cable for Sikorsky Aircraft. Sikorsky Aircraft reserves the right to perform any inspections/tests set forth in this specification to assure suppliers conformance.

4.1.1 Responsibility for Compliance – All methods of marking wire/cable shall meet the requirements of sections 3 and 5. The inspections set forth in this specification shall become a part of the contrac-tor’s overall inspection system and quality program for marking wire/cable. The contractor shall notify in writing and obtain approval from Sikorsky Aircraft at any time there is a change to their approved process. Sampling in quality conformance does not authorize submission of defective material for any portion of the contract quantity, nor does it commit Sikorsky Aircraft to accept defec-tive material.

4.1.2 Test Equipment and Inspection Facilities. Test, measuring equipment and inspection facilities once established shall be maintained by the contractor to assure accuracy, and quality performance.

Establishment and maintenance of the calibration system shall be in accordance with the contrac-tors work instructions to assure accuracy.

4.2 Classification of inspections – The inspections specified herein shall be as follows:

a. Qualification inspection

b. Retention of Qualification

c. Acceptance inspection

4.2.1 Inspection Conditions – All inspections shall be performed in accordance with the test conditions specified herein.

4.3 Qualification Inspection. – Qualification inspection shall consist of all tests as specified in Table 1 and on the qualification test samples described in each section. Qualification tests shall begin once a contractor has agreed to process wire/cable using any of the methods described herein. The con-tractor may choose at their discretion with no additional cost to Sikorsky to either: 1) maintain a serialized list of all product processed until approval is obtained by Sikorsky Aircraft, with the under-standing that they are responsible for any product that is rejected or 2) the contractor perform all of the tests on samples prior to processing any of the production runs and obtain approval by Sikors-ky Aircraft. Samples shall be provided to Sikorsky Aircraft at no additional cost.

Table 1 – Qualification Inspection

Inspection Requirement paragraph Test Method paragraph

Depth and Contrast

Legibility & Adherence

Temperature & Fungus

Insulation Damage

3.5.3 & 3.5.5 4.6.2 &( 4.6.3 or 4.6.4)

3.5.1 & 3.5.2 4.6.5

3.5.6 4.6.8

3.5.4 4.6.6 & 4.6.7

4.3.1 Inspection/Test Failures – The supplier shall be responsible, at its own expense, for rework and reinspection/retest of wire/cable that fails one or more of the qualification requirements specified herein. The supplier shall also be responsible, at its own expense, for notifying Sikorsky Aircraft when failure of one or more qualification requirements may affect wire/cable delivered, and for re-placement of delivered wire/cable that may be affected by the failure.

4.3.2 Retention of Qualification – Retention of qualification requires that the contractor certify upon re-quest with documentation and test reports that they can process the wire/cable and produce a mar-king method that meets all of the defined conditions as originally qualified under the inspections/ tests defined in this specification. The conditions are as follows:

a. same process – Requalification is required only if any part of the marking process changes or no longer can be met, or large quantities of rejections persist or any combinations thereof. (i.e. new filter part number, wire/cable part number, type part number, new equipment).

4.3.2.1 Retention of Qualification samples – For the process that the contractor is qualified, four(4) sam-ples of each part number wire/cable shall be supplied. Contractors shall submit test data for each test defined in this specification.

4.4 Acceptance inspection.

4.4.1 Inspection of the product for delivery– Inspection shall consist of examination of the product in ac-cordance with 4.6.1.

4.4.2 Inspection Lot – An inspection lot shall consist of all of the same wire/cable part number produced under the same process conditions. Any change to pressure, dwell time, temperature, wire/cable part number, foil part number, equipment (including type, letter style, anvils and heads) shall be reason to identify under a new lot.

4.4.3 Sampling plan – Statistical sampling and inspection shall be at the discretion of the contractor in order to assure process control.

4.4.4 Rejected lots – If an inspection lot is rejected this shall be cause for a requalification. The contractor shall notify Sikorsky of any quality conformance changes or inspection point changes. Failure to do so may result in loss of contract and/or legal responsibility.

4.5 Inspection of packaging – Sample packages and packs and the inspection of preservation– pack-aging, packing and marking for shipment and storage shall be in accordance with MIL–C–55330.

4.6 Methods of inspection.

4.6.1 Examination of product. The wire/cable shall be examined to assure compliance with the following requirements:

Table 2 – Acceptance Inspection

Inspection Requirement paragraph Test Method paragraph

Workmanship

Legibility 3.5.3 Visual

3.5.6 4.6.8

4.6.1.1 In – process controls – The contractor shall use in process controls to satisfy 4.6.1. These controls are to be reviewed by Sikorsky. (i.e. in line bead checker).

�-./01234-�.5677�80�14-9:1209�24�0-.:;0�14-<4;=6-10�>325�250�;0?:3;0=0-2.�4<�253.�./013<316234-� �6=/73-@�4<�677�>3;0�16870�4;�=6;A0;�.700B0.�4;�5062�.5;3-A6870�.700B0.�.5677�80�6.�<4774>.C �615�742�D48�2562�3.�=6;A09�62��3A4;.AE�4;�62�6��://730;�<613732E�.5677�56B0�;6-94=�.6=/73-@�94-0 90/0-93-@�4-�3-32367�?:673<316234-�4;�6110/26-10�20.23-@�;0?:3;0=0-2.�90<3-09�50;03-����3-10�32�3.

-42�/;6123167�<4;�1:223-@�.6=/70.�<;4=�0615�>3;0�16870�4;�:.3-@�=6;A0;�.700B0.�4;�5062�.5;3-A6870 .700B0.�<;4=�/;49:1234-�320=.#�.54/�.5677�<:;-3.5�.6=/70.�24�3-./01234-�<;4=�0615�742�D48�2562�3.

14=/70209�24�6..:;0�250�/;410..�3.�:-90;�14-2;47����53.�>377�9020;=3-0�3<�6�>3;0�16870�-009.�24�80 ?:673<309�6-9�.:8D01209�24�90.2;:123B0�20.23-@����.�6�;014==0-96234-�32�3.�3=/4;26-2�=6-:<612:;' 3-@�A00/�6-�:/96209�74@�24�0-.:;0�2;610683732E�4<�677�D48.�<4;�6-E�-4-�14-<4;=32E�4<�=6;A3-@�3-�16.0 6�=6D4;�/;4870=�3.�93.14B0;09�9:;3-@�;6-94=�.6=/73-@�20.2����50�?:6-232E�4<�3-./01234-�1501A.

.5677�80�62�250�93.1;0234-�4<�250�F:6732E��..:;6-10��0/6;2=0-2�

G

4.6.2 ADHERENCE TEST – rub (one pass over marking) six (6) test specimens with an abrasive felt(fed-eral specification C–F–206 Type I, Class 9R4) using a weight of 2 pounds � .25 pounds for areas that are are stamped prior to any solvent application. The weight shall include the fixture head.

The felt surface shall be 0.187 and 0.25 inches wide and shall be in complete contact with printed characters. A speed of 30 to 60 rubs per minute shall be maintained. At completion of test wires/ cables shall meet legibility per para 3.5.3. A repeated scrape abrasion tester, type GE512040G1 or type Wellman may be used.

4.6.3 SOLVENT RESISTANCE TEST FOR LASER, INKJET, SLEEVE MARKERS & HEAT SHRINK.

ALL methods of Marking except for wraparound sleeves shall meet environmental and solvent re-sistance requirements Immersion test (Table 3) as defined herein as follows. Each mark shall be subject to 24 hour soak and after the soak air–dried for 24 hours and then examined to meet the requirements of para 3.5.3 and 3.5.6.

Test Fluids

Test Fluid Temperature

(+/– 2 degrees C)

MIL–H–5606, Hydraulic Fluid

MIL–PRF–5624, JP–4 or JP–5 or Jet A Fuel

MIL–PRF–7808, Lubricating Oil, Aircraft Turbine Engine

Isopropyl Alcohol TT–I–735

Salt Water, 5% solution by Volume

Table 3 – Immersion Test

SAE AS–1241 Hydraulic Fluid (Skydrol) 70

4.6.4 SOLVENT RESISTANCE TEST FOR WRAPAROUND SLEEVES– Wraparound sleeves shall meet environmental and solvent resistance requirements as defined in the Seven day test (Table IV) below. Each mark shall then meet requirements of para 3.5.3 and 3.5.6. In addition the clear polyester or polimide tape shall not become detached.

Test

150° C dry heat to –40° C cold antifreeze soak, MIL–E–9500 or ASTM E1119 motor oil soak, MIL–PRF–7808 or MIL–PRF–23699 salt water soak , 5% concentration transmission fluid soak , hydraulic – MIL–H–5606 or MIL–H–83282

Table 4 – Seven day Test (168 hrs)

Test Fluid Temperature

(+/– 2 degrees C)

4.6.5 CONTRAST AND DEPTH TEST –

Depth – The indentation into the surface of each insulating material for wire/cable shall be mea-sured with a contour projector or calibrated microscope. Measurements shall be made to an accu-racy of one ten–thousandth of an inch. Three characters from each set of markings shall be se-lected at random and measured for depth of indentation. Whenever a measurement is made and found to have an indentation greater than the maximum specified in 3.5.1 the marking shall be con-sidered a failure. THIS CAN ALSO BE ACCOMPLISHED USING A ZYGO MEASURING DEVICE.

�4-2;6.2�$H�����""����2562�6��/012;:=��015-474@E��"�+��4-2;6.2�"06.:;3-@��E.20=�80 :.09�<4;�253.�./013<316234-�3-�6114;96-10�>325�250�=6-:<612:;0;.�3-.2;:1234-.���50�.16--0;�.54:79 80�.02�24�250�I�:24J�=490��"06.:;0�250�14-2;6.2�4<�.3K�=6;A.�#�250�6B0;6@0�B67:0.�48263-09�3.�250 20.2�;0.:72�<4;�14-2;6.2�

4.6.6 TEMPERATURE TEST– The wire/cable shall be placed into a preheated air circulating oven and brought to the maximum high temperature the wire/cable is rated for, for one hour. Within a few minutes the wire/cable shall be placed into a cold chamber and brought to the maximum low temper-ature the wire/cable is rated for, for one hour. Then the wire/cable shall be brought back to room temperature for one hour. The wire/cable shall then be tested for adherence per para 4.6.2 and meet the requirements of para 3.5.3.

4.6.7 ENVIRONMENTAL TEST

FUNGUS TEST– All methods of marking shall show no evidence of fungus growth and shall have a value of 1 or less in accordance with ASTM G 21.

4.6.8 INSULATION DAMAGE TEST –

All methods of marking shall show no evidence of cracking, peeling or cutting of the insulation when visually inspected with a 4X microscope. There may be a slight dust residue from the laser marking without affecting performance or contrast.

YAG – LASER ONLY – MANDREL WRAP TEST – A 12 inch minimum length of wire shall be sub-jected to four cycles of bending at room temperature for qualification and one cycle for acceptance.

One cycle shall consist of the wire/cable being tightly wrapped against the mandrel winding the wire (5 loops minimum) around a mandrel, specified in Table IV, unwinding and reverse winding the wire (each loop shall be approximately separated at a distance of 3X the applicable wire/cable diameter).

At least one marking pattern shall be on the outside of the wire during the wrapping. After the fourth cycle, the wire shall be checked using 6X to 10X magnification for splitting or cracking of insulation and to assure that there is no exposure of the bare copper wire. Defective wire typically shows cracks starting from “E’s, T’s, I’s, 1’s, f’s and –s under magnification. Wire/cable subject to four cycle test shall not be used for aircraft use or solvent and adherence test.

TABLE IV

MANDREL TEST DIAMETERS

WIRE GAUGE MANDREL DIAMETER

(L0.003 INCH)

0.125 0.125 0.250 0.250 0.250 0.375 0.500 0.500

10Xand larger wire diameter

5.0 PREPARATION FOR DELIVERY

5.1 Packing – Suitable packaging shall be used to prevent marring, scarring and other handling dam-age that could affect the integrity of the wire/cable.

5.2 Affidavits – A certified affidavit when requested stating that the wire/cable supplied has passed all acceptance test specified herein shall be available to be supplied to Sikorsky.

6.0 NOTES.

ALL Wire/cable, marker sleeves and heat shrinkable tubing shall be marked in accordance with

SS7333.

EXCEPTIONS: SHALL BE ONLY AT THE APPROVAL OF SIKORSKY AIRCRAFT AND SHALL

BE IN ACCORDANCE WITH SS7334.

7.0 Approved Suppliers/Contractors

7.1 Purchasing shall not use any wire/cable contractors that have not been approved for marking espe-cially a new source of supply. New suppliers require approval by the S–2000 electrical commodity team. Existing suppliers shall perform the qualification and acceptance test as described herein per the wiring criteria in SS9208.