W912LP-16-0017_-_Comm_Install_Bldg_124_with_drawing.pdf

PDF 395 KB Posted

Attached to
Comm Install Bldg 124 Federal contract opportunity
Solicitation number
W912LP-16-T-0017
Issued by
Department of the Army Iowa Army National Guard

About this file

Solicitation

View the file

Other files for this federal contract opportunity

Other files attached to Comm Install Bldg 124, newest first.
File Type Posted
Access_Request_Letter_PDF.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SEE ADDENDUM

(No Collect Calls)

W912LP-16-T-0017 29-Jul-2016

b. TELEPHONE NUMBER

515-261-8522

8. OFFER DUE DATE/LOCAL TIME

10:00 AM 11 Aug 2016

5. SOLICITATION NUMBER 6. SOLICITATION ISSUE DATE

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

STANDARD FORM 1449 (REV. 2/2012)

Prescribed by GSA – FAR (48 CFR) 53.212

(TYPE OR PRINT)

(SIGNATURE OF CONTRACTING OFFICER)

ADDENDA X ARE

26. TOTAL AWARD AMOUNT (For Gov t. Use Only )

23.

CODE 10. THIS ACQUISITION IS

SUCH ADDRESS IN OFFER

17b. CHECK IF REMITTANCE IS DIFFERENT AND PUT

BELOW IS CHECKED

TELEPHONE NO.

W912LP9. ISSUED BY

18b. SUBMIT INVOICES TO ADDRESS SHOWN IN BLOCK 18a. UNLESS BLOCK

7. FOR SOLICITATION

INFORMATION CALL:

a. NAME

MARK J. NEHRING

2. CONTRACT NO. 3. AWARD/EFFECTIVE DATE 4. ORDER NUMBER

(TYPE OR PRINT)

30b. NAME AND TITLE OF SIGNER 30c. DATE SIGNED 31b. NAME OF CONTRACTING OFFICER

30a. SIGNATURE OF OFFEROR/CONTRACTOR 31a.UNITED STATES OF AMERICA

1 27a. SOLICITATION INCORPORATES BY REFERENCE FAR 52.212-1. 52.212-4. FAR 52.212-3. 52.212-5 ARE ATTACHED.X

25. ACCOUNTING AND APPROPRIATION DATA

1. REQUISITION NUMBER

20.

ADDITIONAL SHEETS SUBJECT TO THE TERMS AND CONDITIONS SPECIFIED.

OFFEROR TO COMPLETE BLOCKS 12, 17, 23, 24, AND 30

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

F7F3FU6173AW01

ARE NOT ATTACHED

27b. CONTRACT/PURCHASE ORDER INCORPORATES BY REFERENCE FAR 52.212-4. FAR 52.212-5 IS ATTACHED. ADDENDA ARE ARE NOT ATTACHED

(BLOCK 5), INCLUDING ANY ADDITIONS OR CHANGES WHICH ARE

SET FORTH HEREIN, IS ACCEPTED AS TO ITEMS:

. YOUR OFFER ON SOLICITATION

28. CONTRACTOR IS REQUIRED TO SIGN THIS DOCUMENT AND RETURN

% FOR:SET ASIDE:UNRESTRICTED OR X

SMALL BUSINESSX

17a.CONTRACTOR/ CODE FACILITY

OFFEROR CODE

132D WG / MSC- BASE CONTRACTING - FA6141

3100 MCKINLEY AVENUE

DES MOINES IA 50321-2720

18a. PAYMENT WILL BE MADE BY CODE

RATED ORDER UNDER

DPAS (15 CFR 700)

13a. THIS CONTRACT IS A

13b. RATING

CODE15. DELIVER TO CODE 16. ADMINISTERED BY

SEE SCHEDULE

12. DISCOUNT TERMS11. DELIVERY FOR FOB DESTINA-

TION UNLESS BLOCK IS

MARKED

SEE SCHEDULE

14. METHOD OF SOLICITATION

RFQ IFB RFPX

(515) 261-8029FAX:

TEL: (515) 261-8523 SERVICE-DISABLED

VETERAN-OWNED

SMALL BUSINESS

8(A)

HUBZONE SMALL

BUSINESS

SIZE STANDARD:

$15,000,000

NAICS:

238210

X

OFFER DATED

29. AWARD OF CONTRACT: REF.

DELIVER ALL ITEMS SET FORTH OR OTHERWISE IDENTIFIED ABOVE AND ON ANY

COPIES TO ISSUING OFFICE. CONTRACTOR AGREES TO FURNISH AND

EMAIL:

TEL:

31c. DATE SIGNED

SEE SCHEDULE

SCHEDULE OF SUPPLIES/ SERVICESITEM NO. QUANTITY UNIT UNIT PRICE AMOUNT

24.22.21.19.

WOMEN-OWNED SMALL BUSINESS (WOSB)

ELIGIBLE UNDER THE WOMEN-OWNED

SMALL BUSINESS PROGRAM

EDWOSB

32g. E-MAIL OF AUTHORIZED GOVERNMENT REPRESENTATIVE

SOLICITATION/CONTRACT/ORDER FOR COMMERCIAL ITEMS

(CONTINUED)

PAGE 2 OF46

ACCEPTED, AND CONFORMS TO THE CONTRACT, EXCEPT AS NOTED: ______________________________________________________

32a. QUANTITY IN COLUMN 21 HAS BEEN

RECEIVED INSPECTED

32b. SIGNATURE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32c. DATE 32d. PRINTED NAME AND TITLE OF AUTHORIZED GOVERNMENT

REPRESENTATIVE

32e. MAILING ADDRESS OF AUTHORIZED GOVERNMENT REPRESENTATIVE 32f . TELEPHONE NUMBER OF AUTHORIZED GOVERNMENT REPRESENTATIVE

37. CHECK NUMBER

FINALPARTIALCOMPLETE

36. PAYMENT35. AMOUNT VERIFIED

CORRECT FOR

34. VOUCHER NUMBER

FINAL

33. SHIP NUMBER

PARTIAL

38. S/R ACCOUNT NUMBER 39. S/R VOUCHER NUMBER 40. PAID BY

41a. I CERTIFY THIS ACCOUNT IS CORRECT AND PROPER FOR PAYMENT

41b. SIGNATURE AND TITLE OF CERTIFYING OFFICER 41c. DATE

42a. RECEIVED BY (Print)

42b. RECEIVED AT (Location)

42c. DATE REC'D (YY/MM/DD) 42d. TOTAL CONTAINERS

STANDARD FORM 1449 (REV. 2/2012) BACK

Prescribed by GSA – FAR (48 CFR) 53.212

AUTHORIZED FOR LOCAL REPRODUCTION

PREVIOUS EDITION IS NOT USABLE

SEE SCHEDULE

20.

SCHEDULE OF SUPPLIES/ SERVICES

21.

QUANTITY UNIT

22. 23.

UNIT PRICE

24.

AMOUNT

19.

ITEM NO.

W912LP-16-T-0017

Section SF 1449 - CONTINUATION SHEET

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0001 1 Job Comm Install Bldg 124

FFP

Comm Install Bldg 124

Supply and install communications items in Bldg 124 in accordance with the attached SOW and drawing.

A site visit will be conducted on Wednesday 3 August 2016 at 10:30 am (Central) in the Wing Classroom Bldg 100, 3100 McKinley Ave, Des Moines, IA 50321.

Attendence to the site visit will be required to submit a quotation. You must submit an Entry Authorization Request to patrick.j.olson.mil@mail.mil. The request document will be an attachment in FBO. It is suggested that you arrive to base early to avoid delays entering.

FOB: Destination

PURCHASE REQUEST NUMBER: F7F3FU6173AW01

SIGNAL CODE: A

NET AMT

ITEM NO SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT

0002 1 Job Contractor Manpower Reporting

FFP

Contractor Manpower Reporting

Contractor Manpower Reporting Application (eCMRA)

"The contractor shall report ALL contractor labor hours (including subcontractor labor hours) required for performance of services provided under this contract for the Army collection site. The contractor is required to completely fill in all required data fields using the following web address: http://www.ecmra.mil/.

Reporting inputs will be for the labor executed during the period of performance during each Government fiscal year (FY), which runs October 1 through September 30. While inputs may be reported any time during the FY, all data shall be reported no later than October 31 of each calendar year.

Contractors may direct questions to the help desk at http://www.ecmra.mil/."

The following is applicable to this acquisition:

The Department of Defense Activity Address Code (DODAAC) is W912LP The Unit Identification Code (UIC) for the requiring activity is (FFHVC0)

*For contracts with the Air National Guard, please click on the Department of the Air Force CMRA to register the contract.

FOB: Destination

PURCHASE REQUEST NUMBER: F7F3FU6173AW01

SIGNAL CODE: A

NET AMT

STATEMENT OF WORK

Statement of Work (SOW) For

Building 124 COS Controlled Area Communications requirement

1. PURPOSE

The 132d Wing, Iowa Air National Guard at Des Moines, Iowa is remodeling the upper level COS Controlled Area of building 124 and will require the installation of new and upgraded communications infrastructure. The work described within this Statement of Work will support the communications requirements for this project. This document establishes the general guidance for the expectations for the contractor hired to accomplish this project. The intent of this project is to provide secure and non-secure communication capabilities for the remodeled area of the building.

2. OBJECTIVES

The objective of the project is to install all the needed communications equipment and cabling for the remodeled area of the COS Controlled Area of the upper level of building 124. This area will provide the use of multiple secure and non-secure computer and phone systems, television feed and public announcement system.

3. PROJECT DETAILS

The contractor is responsible for all aspects required for completion of this project as indicated in the purpose above to include placing of racks if needed, pulling cable, providing cable and fiber, splicing, terminating, labeling, and testing. Any other equipment or parts required for this project, not noted in this statement of work, shall be supplied and installed by the contractor.

All work shall conform to Base Communications Tab D, EIA/TIA standards, National Electrical Code, Engineering Technical Letters (ETLs), Local Codes, and other specifications listed in this statement of work.

The following will be accomplished:

A. Place racks B. Pull and terminate fiber and copper in racks with appropriate patch panels C. Terminate with appropriate jacks and faceplates at user locations D. Ground all racks and building entrance protectors to main ground bus E. Test and label and provide as built drawings all cable and fiber and provide test results to 132CF in mutually agreed upon format

4. SCOPE OF WORK- DATA

A. This specification establishes the general specifications for a "universal" premise distribution system that will support all industry standards compliant applications and allow multi-vendor on shared media to meet the voice, data, image, and sensor communications needs of the Owner.

B. The data system shall consist of horizontal fiber cabling, copper cabling, jacks, patch panels, and equipment racks sourcing in room 261.

4.2 GENERAL SPECIFICATION INFORMATION

A. All copper cabling materials and components shall comply with Category 6 performance requirements of the TIA/EIA-

568-B Standard which specifies a minimum bandwidth of 250 MHz. Copper patch panels shall be rack mountable and provide cable management for protection of patch cords and cables while maintaining minimum bend radius requirements. All fiber cabling shall be 50 micron, 2 strand, laser-enhanced, 10 Gig, 300 meter, multi-mode, red-color jacketed, fiber optic cable with LC connectors at both ends to each fiber optic location(s). Fiber optic connectors shall be booted and strain relieved. A 3-meter loop shall be dressed above the ceiling at each location. Fiber faceplates will be appropriately sized for the termination location depending on the number of workstations to be fed. Fiber optic patch panels shall be rack mountable and provide cable management for protection of patch cords and cables while maintaining minimum bend radius requirements.

B. The telecommunication system shall include installation and testing of all cabling, equipment and materials necessary to form complete and operational systems.

C. The copper cable lengths on each horizontal run shall not exceed 90-meters (295-feet). No length limitations on fiber.

D. All work shall conform to Tab D base requirements, the latest edition of the National Electrical Code, the Building

Code and all local codes and ordinances as applicable. TIA/EIA 568B shall be adhered to during all installation activities. Methodologies outlined in the latest edition of the BICSI Telecommunications Distribution Methods Manual shall also be used during all installation activities. Should conflicts exist with the foregoing, the authority having jurisdiction of enforcement will have responsibility for making interpretation.

E. The Installer will be responsible for keeping all aspects of the cable system within fire codes during construction and at the project completion.

F. The Installer will be responsible for keeping the existing data and telephone systems operational during all phases of construction.

G. Cable Supports. Cable routing trays will be utilized and any cable routing that is required outside of the cable tray will be accomplished with appropriately positioned j-hooks or rings for 10 or less cables only. 10 or more cables shall use appropriated sized straps. Supports shall be installed using manufacturer’s installation guidelines.

H. Labeling. All jacks will be labeled consecutively corresponding to the patch panel jack number following current numbering pattern in place. Reference Base Communications Tab D.

4.3 QUALITY ASSURANCE

A. The Telecommunication Contractor shall have not less than five (5) years’ experience installing telecommunication systems. The Contractor shall provide not less than six (6) references for projects of similar scope and specifications.

Proof of experience and qualifications will be required.

B. Contractor to be certified by manufacturer prior to submitting bid. No exception of being certified after project is awarded.

4.4 DESCRIPTION OF WORK

A. The Installer shall furnish and install all materials necessary to install cabling from each work area jack to the designated telecommunication closet or patch panel.

B. The Installer shall test all cables after installation to insure proper connections and show compliance with the specified standards.

4.5 SUBMITTALS

A. As a minimum, the following items shall be submitted along with the quotation.

1. Experience, qualifications and telecommunications contractor certification.

2. A copy of the system warranty written for this Project.

3. Manufacturer's data sheets for all products used.

4. One line schematic drawing showing quantity, location and connection of all telecommunication components.

This shall include elevations of all equipment racks indicating patch panels, equipment shelves and required space.

5. Test results, record drawings and documentation.

5- PRODUCTS

5.1 ACCEPTABLE MANUFACTURERS

A. Manufacturers: Subject to compliance with requirements, provide telecommunication systems end to end solution of the following: System warranty shall be written through the connectivity manufacturer. Submittals required to be submitted on AF Form 3000 to the Contracting Officer prior to purchase of all products.

5.2 SHIELDED TWISTED PAIR CABLE SYSTEM FOR DATA

A. Horizontal Cable. Cable shall be label verified. Cable jacket shall be factory marked at regular intervals indicating verifying organization and performance level. Conductors shall be 4-pair solid untinned copper 24 AWG. Cable shall be plenum rated CMP per NFPA 70.

B. Copper Data Outlets. Wall outlet plates shall include modular 8-position jacks, quantity as indicated on the drawings.

Modular jack pin/pair configuration shall be T568B. Modular jacks shall be un-keyed. Faceplates shall be labeled face plates with recessed labeling field included to accept label card and clear plastic cover. Faceplate material and finish shall match faceplates for other wiring devices in the same room or space.

C. Patch Panels for Data. Patch panels shall consist of 8-position modular jacks, arranged in rows or columns on 19-inch rack mounted panels. Jack pin/pair configuration shall be T568B. Jacks shall be unkeyed. Panels shall be provided with labeling space. Patch panels shall be 24 or 48 port as applicable. Provide quantity of patch panels required to accommodate the installed cable plant plus 20% spares.

D. Copper Patch Cords: Factory-made, Shielded four-pair cables. Provide 40% at 7’ and 60% at 10’ lengths; terminated with eight-position modular plug at each end.

1. Patch cord shall have bend-relief-compliant boots and color-coded icons to ensure Category 6 performance.

Patch cords shall have latch guards to protect against snagging.

2. Color and quantity- Green color, (1) for each modular jack in face plate for project plus 20% spares.

3. Color and quantity- Blue color, (1) for each modular jack in face plate for project plus 20% spares

4. Contractor to coordinate with owner prior to ordering and installing patch cords.

E. Work Area Patch Cords: Factory-made, Shielded four-pair cables in 25’ lengths and 15’ lengths; terminated with eight-position modular plug at each end.

1. Patch cords shall have bend-relief-compliant boots and color-coded icons to ensure Category 6 performance.

Patch cords shall have latch guards to protect against snagging.

2. Color and quantity- Green color, (1) for each modular jack in face plate for project plus 20% spares.

3. Color and quantity- Blue color, (1) for each modular jack in face plate for project plus 20% spares

4. Contractor to coordinate with owner prior to ordering and installing patch cords.

FIBER OPTIC CABLE SYSTEM - MULTIMODE

I. Backbone cable. Multimode fiber optic backbone cable shall be used. Cable shall be 50/125 laser optimized micrometer multimode graded index optical fiber cable. Cable construction shall be tight buffered type. Individual fibers shall be color coded for identification. Cable shall be imprinted with fiber count and aggregate length at regular intervals. Cable shall be plenum rated OFNP per NFPA 70.

J. Connectors shall be duplex LC type. Connectors shall be field installable.

K. Patch Panels. Fiber optic adapters shall be provided to align and join the fiber optic connectors allowing a means to cross connect or interconnect premises equipment to the optical fiber cabling. Adapters shall be housed in rack mounted panels and shall have sliding drawers to store fiber loops and tinted removable Plexiglas covers to protect the fiber connectors. Quantity of patch cords and adapters shall be sufficient to accommodate the installed cable plant plus 5% spare.

L. Fiber Patch Cords: Simplex and duplex cable connectors.

1. Patch cords: Factory-made, dual-fiber cables in 10’ lengths.

2. Contractor to coordinate with the owner prior to ordering and installation of patch cords.

M. Cable Connecting Hardware:

1. Comply with Optical Fiber Connector Intermateability Standards (FOCIS) specifications of TIA/EIA-604-2, TIA/EIA-604-3-A, and TIA/EIA-604-12. Comply with TIA/EIA-568-B.3.

2. Quick-connect, simplex and duplex, Type LC connectors. Insertion loss not more than 0.75 dB.

5.3 EQUIPMENT RACKS – FLOOR MOUNTED

A. Floor mounted equipment racks shall be 4 post 42U enclosure with side panels to mount equipment 19-inches wide.

Each rack shall be approximately 42” deep, 89” tall and 29.5” wide. Each rack shall have a mesh perforated front and back door to allow air flow. Each rack shall have a top mounted cooling fan tray and include vertically mounted metered power strips with 20A input plugs. Each rack shall have at least 40% available space for use by Owner at completion of cable installation.

B. Cable guides shall be specifically manufactured for the purpose of routing cables, wires and patch cords horizontally and vertically on 19-inch equipment racks. Cable guides shall consist of ring or bracket like devices mounted on rack panels for horizontal use or individually mounted for vertical use. Cable guides shall mount to racks by screws and/or nuts and lock-washers. Provide sufficient quantity of cable guides to fill rack (for both active and spare sections of rack). Vertical cable management with door covers on both sides. Horizontal cable management with door covers.

6 - INSTALLATION

6.1 GENERAL

A. System components and appurtenances shall be installed in accordance with NFPA 70, manufacturer's instructions and as shown. Necessary interconnections, services, and adjustments required for a complete and operable signal distribution system shall be provided. Components shall be labeled in accordance with TIA/EIA 606. Penetrations in fire rated construction shall be fire-stopped. Conduits, outlets and raceways shall be installed in accordance with Division 26. Wiring shall be installed in accordance with EIA/TIA 569A. Wiring, and terminal blocks and outlets shall be marked in accordance with TIA/EIA 606. Cables shall not be installed in the same cable tray, utility pole compartment, or floor trench compartment with ac power cables. Cables not installed in conduit or wire-ways shall be properly secured and neat in appearance and, if installed in plenums or other spaces used for environmental air, shall comply with NFPA 70 requirements for this type of installation.

B. Horizontal Distribution Cable. All cables shall be installed in a continuous raceway from each data outlet box to cable tray, router location, or communication room as indicated on the drawings. Provide insulated bushing at each end of conduit. The rated cable pulling tension shall not be exceeded. Cable shall not be stressed such that twisting, stretching or kinking occurs. Cable shall not be spliced. Cable shall not be run through structural members or in contact with pipes, ducts or other potentially damaging items. Placement of cable parallel to power conductors shall be avoided, if possible; a minimum separation of 12-inches shall be maintained when such placement cannot be avoided.

Cables shall be terminated; no cable shall contain unterminated elements. Minimum bending radius shall not be exceeded during installation or once installed. Cable ties shall not be excessively tightened such that the transmission characteristics of the cable are altered.

C. Labeling. As a minimum, every jack, cable and patch panel port shall be labeled as to its function and a unique number to identify cable link. The labeling scheme shall be approved by the Owner and in general shall conform to Class 1 or Class 2 Administration Standards per TIA/EIA 606 (Class 1 Standards apply to facilities without backbone cables).

Labels at a minimum shall be typewritten or computer printer generated on the labeling field cards.

D. Patch panels shall be mounted in equipment racks. Cable guides shall be provided above, below and between each panel.

E. Open frame equipment racks shall be bolted to the floor. Cable guides shall be bolted or screwed to racks. Racks shall be installed level. Ganged racks shall be bolted together.

G. Equipment to be rack mounted shall be securely fastened to racks by means of the manufacturer's recommended fasteners.

H. Cable Management: Provide cable tray and other wire management hardware as required to properly support all cable within telecommunications closets. Bundles of cable without wire management shall not be acceptable.

I. Cable Ties: Provide velcro (hook and loop) cable ties for all cable ties in telecommunications closets.

6.2 TERMINATION

A. Cables and conductors shall sweep into termination areas; cables and conductors shall not bend at right angles.

Manufacturer's minimum bending radius shall not be exceeded. When there are multiple system type drops to individual workstations, relative position for each system shall be maintained on each system termination block or patch panel.

B. Provide service loops at the corridor cable tray and in the telecommunication closet. In the corridor cable tray provide a minimum cable slack of 12-inches for UTP, cables and 40-inches for optical fiber cables. In the telecommunication closets provide a minimum cable slack of 10-feet for both UTP and optical fiber cables. Cable slack shall be neatly placed in and supported by cable trays located above the equipment racks.

C. Shielded Twisted Pair Cable: Each pair shall be terminated on appropriate outlets, terminal blocks or patch panels.

Pairs shall remain twisted together to within the proper distance from the termination. Conductors shall not be damaged when removing insulation. Wire insulation shall not be damaged when removing outer jacket.

D. Fiber Optic Cable: Each fiber shall have connectors installed. The pull strength between the connector and the attached fiber shall be not less than 25 lbs.

6.3 GROUNDING

A. Signal distribution system ground shall be installed in the Telecommunications Entrance Facility and in each telecommunications closet in accordance with TIA/EIA 607. Equipment racks shall be connected to the electrical safety ground. Telecommunication main grounding bus.

6.4 TESTING

A. Materials and documentation to be furnished under this specification are subject to inspections and tests. All components shall be terminated prior to testing. Equipment and systems will not be accepted until the required inspections and tests have been made, demonstrating that the signal distribution system conforms to the specified requirements, and that the required equipment, systems and documentation have been provided.

B. Shielded Twisted Pair Tests: Correct color coding and termination of each pair shall be verified in the communications closet and at the outlet. Horizontal wiring shall be tested from and including the termination device in the communications closet to and including the modular jack in each room. These tests shall be completed and all errors corrected before any other tests are started. All STP links shall be tested using an approved test set. Testing shall use the Permanent Link Test procedure. Cables which contain failed circuits shall be replaced and retested to verify the standard is met.

C. Fiber Optic Cable: Unless stated otherwise, tests shall be performed from both ends of each circuit. Connectors shall be visually inspected for scratches, pits or chips and shall be re-terminated if any of these conditions exist. Each fiber shall be tested for insertion loss at 850 and 1300 nm using a fiber optic certification test set. Fibers that do not meet the criteria of TIA/EIA 568B.1 shall be replaced and/or re-terminated and then retested to verify the standard is met. Test results shall include the calculated maximum link attenuation acceptance values along with the actual test result for each fiber tested.

D. The Engineer may request that a 10% random field retest be conducted on the cable system in the presence of the

Engineer at no additional cost to verify documented findings. Tests shall be a repeat of those defined above. If findings contradict the documentation submitted by the Contractor, additional testing can be requested to the extent determined necessary by the Engineer, including a 100% retest. This retest shall be provided at no additional cost.

E. Test Documentation: All test results shall be documented and furnished to the Owner in both electronic and hard copy format. The hard copy shall be furnished with a 3-ring binder and properly organized. Requirements for electronic copy shall be coordinated with Owner.

6.5 COMPLETION OF PROJECT

A. The Project will not be considered complete until after the Installer has finished the following tasks:

1. All testing has been completed and the Installer certifies that the installation meets all specified tolerances. The Installer shall submit all test documentation and results to the Engineer.

2. All ceiling tiles, where applicable, that may have been removed by the Installer have been replaced and clean-up of debris created during the installation process has been finished.

3. Provide record drawings that includes; as-built information, cable routing, jack locations and Telecommunication Room Layouts. Jack locations shall be identified by their sequential number as defined elsewhere in this document.

Numbering, icons and drawing conventions used shall be consistent throughout all documentation provided.

4. All documentation and drawings have been submitted to the Engineer.

5. All locations have been labeled on the faceplate and the patch panel in accordance to labeling requirements as specified. Labeling shall include closet locations, room numbers and jack locations.

7. WARRANTIES

All work will be guaranteed for workmanship, materials, and successful operation of all equipment installed for a minimum of one (1) year from the date of final acceptance by the 132 CF. This warranty shall include but not be limited to system functionality, cable connections, and general system installation.

8. DELIVERABLES

A. As-built drawings will be provided in an electronic means in a format agreed to by both parties B. Materials submittals

9. ANTI-TERRORISM & OPSEC REQUIREMENTS

1. The contractor shall comply with all applicable installation/facility access and local security policies and procedures, which may be obtained from the Contracting Officer’s Representative (COR). The contractor shall also provide all information required for background checks to meet installation access requirements to be accomplished by the local installation’s Security Forces, Director of Emergency Services or local Security Office. The contractor shall ensure compliance with all personal identity verification requirements as directed by DoD, HAF and/or local policy. Should the Force Protection Condition (FPCON) change, the Government may require changes in contractor security matters or processes.

2. All contractor employees, to include subcontractor employees, requiring access Government Installations, Facilities and Controlled Access areas shall complete AT Level I awareness training within 10 calendar days after contract start date or effective date of incorporation of this requirement into the contract, whichever is applicable. Certificates of completion for each affected contractor employee and subcontractor employee will be maintained by the COR or Antiterrorism Representative. AT level I Awareness Ttraining is available at the following website: http://jko.jten.mil

Communications Requirements for COS Bldg 124 See attached Schematic for Additional Information

SERVER RACK – (Qty - 1) Cabinet approximate dimensions:

42" deep 89" tall 29.5" wide (extra space on sides for cable management)

Cabinet requirements:

Enclosure with sides 19" rack size Mesh / perforated front and back for air flow Top mounted cooling fan tray installed in rack Vertically mounted metered power strip (with 20a input plug) installed in rack

Patch Panel requirements:

Red Multi‐Mode LC x61

Green Shielded RJ45 x41

Blue Shielded RJ45 x20

COMMUNICATIONS DROPS, FACEPLATES, CABLING

Wall jacks need to be shielded, grounded, colored, modular, non‐keyed (if possible), to match patch panels

4 wall drops for workstations

Each drop to have:

15 red multimode LC

5 black multimode LC

10 green STP RJ45

5 blue STP RJ45

5 white STP RJ45

5 black multimode LC

2 wall drops for printers

1 drop will be green STP RJ45 1 drop will be red multimode LC

INSPECTION AND ACCEPTANCE TERMS

Supplies/services will be inspected/accepted at:

CLIN INSPECT AT INSPECT BY ACCEPT AT ACCEPT BY

0001 Destination Government Destination Government 0002 Destination Government Destination Government

DELIVERY INFORMATION

CLIN DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC

0001 45 dys. ADC 1 F7F3FU COMM PLANS

3100 MCKINLEY AVE

DES MOINES IA 50321

515-256-8584 FOB: Destination

F7F3FU

0002 31-OCT-2016 1 N/A

FOB: Destination

CLAUSES INCORPORATED BY REFERENCE

52.212-1 Instructions to Offerors--Commercial Items OCT 2015 52.212-4 Contract Terms and Conditions--Commercial Items MAY 2015 52.232-40 Providing Accelerated Payments to Small Business

Subcontractors

DEC 2013

252.203-7000 Requirements Relating to Compensation of Former DoD Officials

SEP 2011

252.203-7005 Representation Relating to Compensation of Former DoD Officials

NOV 2011

252.204-7008 Compliance With Safeguarding Covered Defense Information Controls

DEC 2015

252.204-7012 Safeguarding Covered Defense Information and Cyber Incident Reporting.

DEC 2015

252.204-7015 Notice of Authorized Disclosure of Information for Litigation Support

MAY 2016

252.223-7008 Prohibition of Hexavalent Chromium JUN 2013 252.225-7001 Buy American And Balance Of Payments Program-- Basic

(Nov 2014)

NOV 2014

252.232-7003 Electronic Submission of Payment Requests and Receiving Reports

JUN 2012

CLAUSES INCORPORATED BY FULL TEXT

52.209-11 REPRESENTATION BY CORPORATIONS REGARDING DELINQUENT TAX LIABILITY OR A

FELONY CONVICTION UNDER ANY FEDERAL LAW (FEB 2016)

(a) As required by sections 744 and 745 of Division E of the Consolidated and Further Continuing Appropriations Act, 2015 (Pub. L. 113-235), and similar provisions, if contained in subsequent appropriations acts, the Government will not enter into a contract with any corporation that--

(1) Has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability, where the awarding agency is aware of the unpaid tax liability, unless an agency has considered suspension or debarment of the corporation and made a determination that suspension or debarment is not necessary to protect the interests of the Government; or

(2) Was convicted of a felony criminal violation under any Federal law within the preceding 24 months, where the awarding agency is aware of the conviction, unless an agency has considered suspension or debarment of the corporation and made a determination that this action is not necessary to protect the interests of the Government.

(b) The Offeror represents that--

(1) It is [ ] is not [ ] a corporation that has any unpaid Federal tax liability that has been assessed, for which all judicial and administrative remedies have been exhausted or have lapsed, and that is not being paid in a timely manner pursuant to an agreement with the authority responsible for collecting the tax liability; and

(2) It is [ ] is not [ ] a corporation that was convicted of a felony criminal violation under a Federal law within the preceding 24 months.

(End of provision)

52.212-3 OFFEROR REPRESENTATIONS AND CERTIFICATIONS--COMMERCIAL ITEMS (JUL 2016)

The Offeror shall complete only paragraph (b) of this provision if the Offeror has completed the annual representations and certification electronically via the System for Award Management (SAM) Web site located at https://www.sam.gov/portal. If the Offeror has not completed the annual representations and certifications electronically, the Offeror shall complete only paragraphs (c) through (r) of this provision.

(a) Definitions. As used in this provision --

“Economically disadvantaged women-owned small business (EDWOSB) Concern” means a small business concern that is at least 51 percent directly and unconditionally owned by, and the management and daily business operations of which are controlled by, one or more women who are citizens of the United States and who are economically disadvantaged in accordance with 13 CFR part 127. It automatically qualifies as a women-owned small business eligible under the WOSB Program.

"Forced or indentured child labor" means all work or service-

(1) Exacted from any person under the age of 18 under the menace of any penalty for its nonperformance and for which the worker does not offer himself voluntarily; or

(2) Performed by any person under the age of 18 pursuant to a contract the enforcement of which can be accomplished by process or penalties.

Highest-level owner means the entity that owns or controls an immediate owner of the offeror, or that owns or controls one or more entities that control an immediate owner of the offeror. No entity owns or exercises control of the highest level owner.

Immediate owner means an entity, other than the offeror, that has direct control of the offeror. Indicators of control include, but are not limited to, one or more of the following: Ownership or interlocking management, identity of interests among family members, shared facilities and equipment, and the common use of employees.

Inverted domestic corporation means a foreign incorporated entity that meets the definition of an inverted domestic corporation under 6 U.S.C. 395(b), applied in accordance with the rules and definitions of 6 U.S.C. 395(c).

Manufactured end product means any end product in product and service codes (PSCs) 1000-9999, except--

(1) PSC 5510, Lumber and Related Basic Wood Materials;

(2) Product or Service Group (PSG) 87, Agricultural Supplies;

(3) PSG 88, Live Animals;

(4) PSG 89, Subsistence;

(5) PSC 9410, Crude Grades of Plant Materials;

(6) PSC 9430, Miscellaneous Crude Animal Products, Inedible;

(7) PSC 9440, Miscellaneous Crude Agricultural and Forestry Products;

(8) PSC 9610, Ores;

(9) PSC 9620, Minerals, Natural and Synthetic; and

(10) PSC 9630, Additive Metal Materials.

Place of manufacture means the place where an end product is assembled out of components, or otherwise made or processed from raw materials into the finished product that is to be provided to the Government. If a product is disassembled and reassembled, the place of reassembly is not the place of manufacture.

Predecessor means an entity that is replaced by a successor and includes any predecessors of the predecessor.

Restricted business operations means business operations in Sudan that include power production activities, mineral extraction activities, oil-related activities, or the production of military equipment, as those terms are defined in the Sudan Accountability and Divestment Act of 2007 (Pub. L. 110-174). Restricted business operations do not include business operations that the person (as that term is defined in Section 2 of the Sudan Accountability and Divestment Act of 2007) conducting the business can demonstrate--

(1) Are conducted under contract directly and exclusively with the regional government of southern Sudan;

(2) Are conducted pursuant to specific authorization from the Office of Foreign Assets Control in the Department of the Treasury, or are expressly exempted under Federal law from the requirement to be conducted under such authorization;

(3) Consist of providing goods or services to marginalized populations of Sudan;

(4) Consist of providing goods or services to an internationally recognized peacekeeping force or humanitarian organization;

(5) Consist of providing goods or services that are used only to promote health or education; or

(6) Have been voluntarily suspended.

Sensitive technology--

(1) Means hardware, software, telecommunications equipment, or any other technology that is to be used specifically--

(i) To restrict the free flow of unbiased information in Iran; or

(ii) To disrupt, monitor, or otherwise restrict speech of the people of Iran; and

(2) Does not include information or informational materials the export of which the President does not have the authority to regulate or prohibit pursuant to section 203(b)(3) of the International Emergency Economic Powers Act (50 U.S.C. 1702(b)(3)).

Service-disabled veteran-owned small business concern--

(1) Means a small business concern--

(i) Not less than 51 percent of which is owned by one or more service-disabled veterans or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more service-disabled veterans; and

(ii) The management and daily business operations of which are controlled by one or more service-disabled veterans or, in the case of a service-disabled veteran with permanent and severe disability, the spouse or permanent caregiver of such veteran.

(2) Service-disabled veteran means a veteran, as defined in 38 U.S.C. 101(2), with a disability that is service-connected, as defined in 38 U.S.C. 101(16).

"Small business concern" means a concern, including its affiliates, that is independently owned and operated, not dominant in the field of operation in which it is bidding on Government contracts, and qualified as a small business under the criteria in 13 CFR Part 121 and size standards in this solicitation.

Small disadvantaged business concern, consistent with 13 CFR 124.1002, means a small business concern under the size standard applicable to the acquisition, that--

(1) Is at least 51 percent unconditionally and directly owned (as defined at 13 CFR 124.105) by--

(i) One or more socially disadvantaged (as defined at 13 CFR 124.103) and economically disadvantaged (as defined at 13 CFR 124.104) individuals who are citizens of the United States; and

(ii) Each individual claiming economic disadvantage has a net worth not exceeding $750,000 after taking into account the applicable exclusions set forth at 13 CFR 124.104(c)(2); and

(2) The management and daily business operations of which are controlled (as defined at 13.CFR 124.106) by individuals, who meet the criteria in paragraphs (1)(i) and (ii) of this definition.

Subsidiary means an entity in which more than 50 percent of the entity is owned--

(1) Directly by a parent corporation; or

(2) Through another subsidiary of a parent corporation.

Successor means an entity that has replaced a predecessor by acquiring the assets and carrying out the affairs of the predecessor under a new name (often through acquisition or merger). The term “successor” does not include new offices/divisions of the same company or a company that only changes its name.

The extent of the responsibility of the successor for the liabilities of the predecessor may vary, depending on State law and specific circumstances.

Veteran-owned small business concern means a small business concern--

(1) Not less than 51 percent of which is owned by one or more veterans (as defined at 38 U.S.C. 101(2)) or, in the case of any publicly owned business, not less than 51 percent of the stock of which is owned by one or more veterans; and

(2) The management and daily business operations of which are controlled by one or more veterans.

"Women-owned business concern" means a concern which is at least 51 percent owned by one or more women; or in the case of any publicly owned business, at least 51 percent of the stock of which is owned by one or more women; and whose management and daily business operations are controlled by one or more women.

"Women-owned small business concern" means a small business concern--

(1) That is at least 51 percent owned by one or more women or, in the case of any publicly owned business, at least 51 percent of its stock is owned by one or more women; or

(2) Whose management and daily business operations are controlled by one or more women.

Women-owned small business (WOSB) concern eligible under the WOSB Program (in accordance with 13 CFR part 127)”, means a small business concern that is at least 51 percent directly and unconditionally owned by, and the management and daily business operations of which are controlled by, one or more women who are citizens of the United States.

(b) (1) Annual Representations and Certifications. Any changes provided by the offeror in paragraph (b)(2) of this provision do not automatically change the representations and certifications posted electronically on the SAM website.

(2) The offeror has completed the annual representations and certifications electronically via the SAM website accessed through https://www.acquisition.gov. After reviewing the SAM database information, the offeror verifies by submission of this offer that the representations and certifications currently posted electronically at FAR 52.212- 3, Offeror Representations and Certifications--Commercial Items, have been entered or updated in the last 12 months, are current, accurate, complete, and applicable to this solicitation (including the business size standard applicable to the NAICS code referenced for this solicitation), as of the date of this offer and are incorporated in this offer by reference (see FAR 4.1201), except for paragraphs ___ .

[Offeror to identify the applicable paragraphs at (c) through (r) of this provision that the offeror has completed for the purposes of this solicitation only, if any.) These amended representation(s) and/or certification(s) are also incorporated in this offer and are current, accurate, and complete as of the date of this offer. Any changes provided by the offeror are applicable to this solicitation only, and do not result in an update to the representations and certifications posted electronically on ORCA.]

(c) Offerors must complete the following representations when the resulting contract will be performed in the United States or its outlying areas. Check all that apply.

(1) Small business concern. The offeror represents as part of its offer that it ( ___ ) is, ( ___ ) is not a small business concern.

(2) Veteran-owned small business concern. (Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.) The offeror represents as part of its offer that it ( ___ ) is, ( ___ ) is not a veteran-owned small business concern.

(3) Service-disabled veteran-owned small business concern. (Complete only if the offeror represented itself as a veteran-owned small business concern in paragraph (c)(2) of this provision.) The offeror represents as part of its offer that it ( ___ ) is, ( ___ ) is not a service-disabled veteran-owned small business concern.

(4) Small disadvantaged business concern. (Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.) The offeror represents that it ( ___ ) is, ( ___ ) is not a small disadvantaged business concern as defined in 13 CFR 124.1002.

(5) Women-owned small business concern. (Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.) The offeror represents that it ( ___ ) is, ( ___ ) is not a women-owned small business concern.

Note to paragraphs (c)(8) and (9): Complete paragraphs (c)(8) and (c)(9) only if this solicitation is expected to exceed the simplified acquisition threshold.

(6) WOSB concern eligible under the WOSB Program. [Complete only if the offeror represented itself as a women-owned small business concern in paragraph (c)(5) of this provision.] The offeror represents that--

(i) It [ ___ ] is, [ ___ ] is not a WOSB concern eligible under the WOSB Program, has provided all the required documents to the WOSB Repository, and no change in circumstances or adverse decisions have been issued that affects its eligibility; and

(ii) It [ ___ ] is, [ ___ ] is not a joint venture that complies with the requirements of 13 CFR part 127, and the representation in paragraph (c)(6)(i) of this provision is accurate for each WOSB concern eligible under the WOSB Program participating in the joint venture. [The offeror shall enter the name or names of the WOSB concern eligible under the WOSB Program and other small businesses that are participating in the joint venture: ___ .] Each WOSB concern eligible under the WOSB Program participating in the joint venture shall submit a separate signed copy of the WOSB representation.

(7) Economically disadvantaged women-owned small business (EDWOSB) concern. [Complete only if the offeror represented itself as a WOSB concern eligible under the WOSB Program in (c)(6) of this provision.] The offeror represents that--

(i) It [ ___ ] is, [ ___ ] is not an EDWOSB concern, has provided all the required documents to the WOSB Repository, and no change in circumstances or adverse decisions have been issued that affects its eligibility; and

(ii) It [ ___ ] is, [ ___ ] is not a joint venture that complies with the requirements of 13 CFR part 127, and the representation in paragraph (c)(7)(i) of this provision is accurate for each EDWOSB concern participating in the joint venture. [The offeror shall enter the name or names of the EDWOSB concern and other small businesses that are participating in the joint venture: ___ -.] Each EDWOSB concern participating in the joint venture shall submit a separate signed copy of the EDWOSB representation.

(8) Women-owned business concern (other than small business concern). (Complete only if the offeror is a women-owned business concern and did not represent itself as a small business concern in paragraph (c)(1) of this provision.) The offeror represents that it ( ___ ) is, a women-owned business concern.

(9) Tie bid priority for labor surplus area concerns. If this is an invitation for bid, small business offerors may identify the labor surplus areas in which costs to be incurred on account of manufacturing or production (by offeror or first-tier subcontractors) amount to more than 50 percent of the contract price:

(10) HUBZone small business concern. (Complete only if the offeror represented itself as a small business concern in paragraph (c)(1) of this provision.) The offeror represents, as part of its offer, that--

(i) It [ ___ ] is, [ ___ ] is not a HUBZone small business concern listed, on the date of this representation, on the List of Qualified HUBZone Small Business Concerns maintained by the Small Business Administration, and no material changes in ownership and control, principal office, or HUBZone employee percentage have occurred since it was certified in accordance with 13 CFR Part 126; and

(ii) It [ ___ ] is, [ ___ ] is not a HUBZone joint venture that complies with the requirements of 13 CFR Part 126, and the representation in paragraph (c)(10)(i) of this provision is accurate for each HUBZone small business concern participating in the HUBZone joint venture. [The offeror shall enter the names of each of the HUBZone small business concerns participating in the HUBZone joint venture: ___ .] Each HUBZone small business concern participating in the HUBZone joint venture shall submit a separate signed copy of the HUBZone representation.

(d) Certifications and representations required to implement provisions of Executive Order 11246--

(1) Previous Contracts and Compliance. The offeror represents that--

(i) It ( ___ ) has, ( ___ ) has not, participated in a previous contract or subcontract subject either to the Equal Opportunity clause of this solicitation, the and

(ii) It ( ___ ) has, ( ___ ) has not, filed all required compliance reports.

(2) Affirmative Action Compliance. The offeror represents that--

(i) It ( ___ ) has developed and has on file, ( ___ ) has not developed and does not have on file, at each establishment, affirmative action programs required by rules and regulations of the Secretary of Labor (41 CFR Subparts 60-1 and 60-2), or

(ii) It ( ___ ) has not previously had contracts subject to the written affirmative action programs requirement of the rules and regulations of the Secretary of Labor.

(e) Certification Regarding Payments to Influence Federal Transactions (31 U.S.C. 1352). (Applies only if the contract is expected to exceed $150,000.) By submission of its offer, the offeror certifies to the best of its knowledge and belief that no Federal appropriated funds have been paid or will be paid to any person for influencing or attempting to influence an officer or employee of any agency, a Member of Congress, an officer or employee of Congress or an employee of a Member of Congress on his or her behalf in connection with the award of any resultant contract. If any registrants under the Lobbying Disclosure Act of 1995 have made a lobbying contact on behalf of the offeror with respect to this contract, the offeror shall complete and submit, with its offer, OMB Standard Form LLL, Disclosure of Lobbying Activities, to provide the name of the registrants. The offeror need not report regularly employed officers or employees of the offeror to whom payments of reasonable compensation were made.

(f) Buy American Certificate. (Applies only if the clause at Federal Acquisition Regulation (FAR) 52.225-1, Buy American --Supplies, is included in this solicitation.)

(1) The offeror certifies that each end product, except those listed in paragraph (f)(2) of this provision, is a domestic end product and that for other than COTS items, the offeror has considered components of unknown origin to have been mined, produced, or manufactured outside the United States. The offeror shall list as foreign end products those end products manufactured in the United States that do not qualify as domestic end products, i.e., an end product that is not a COTS item and does not meet the component test in paragraph (2) of the definition of “domestic end product.

This is the start of the file's text. The full file is on GovTribe.