B 08 - Amendment 01 - Questions with Answers.docx

DOCX document 22 KB Posted

Attached to
Aqueous Parts Washers Federal contract opportunity
Solicitation number
W912LM-24-Q-0022
Issued by
Department of the Army Minnesota Army National Guard

About this file

This document is a set of questions and answers regarding Amendment 01 to a solicitation for Aqueous Parts Washers. The key details are:

The solicitation requires a minimum inside working height of 35 inches and a turntable diameter of 27 inches. It calls for both a 230V 1 or 3 phase power supply, with a 3HP pump motor. The automatic timers are for the heater shut off, not a separate wash timer. The original solicitation and Statement of Work provide full details on the requirements for the Aqueous Parts Washers.

View the file

Other files for this federal contract opportunity

Other files attached to Aqueous Parts Washers, newest first.
File Type Posted
A 02 SOW Parts Washer.docx DOCX document
B 01 - Combined Synopsis_Solicitation - Parts Washers.docx DOCX document

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Parts Washer

Amendment 01

Below are questions received and answered regarding this solicitation.

1. Question: Can you define the actual working height that is required for both washers?

a. Response: Inside working height 35 inches minimum

2. Question: The call outs for: Bullet 12 “Automatic 7 Day/24-hour timer”, Bullet 14 “Heater Timer. Is the 14 to be a wash timer and the 12 a programmable timer for the heaters?

a. Response: correct in this statement, the timers are for the automatic shut off for the heaters

3. Specs call for both a 120v and a 208 v unit. It can not be both, and for a unit this size 120v will not provide the power. Can you verify 208v power?

a. Response: 230v 1 or 3 phase

4. “Turntable style cleaner with 700-1260 sq inch surface” That covers just about all of our units. The standard way to specify a size is by the diameter of the turntable in inches. Can you tell us what diameter you are requesting?

a. Response: Inside working height- 35”, turntable diameter- 27”

5. The pump says 5 hp but the flow says 150 gpm at 50 psi. You have to have a 7.5 hp pump to get that output.

a. Response: Pump motor size- 3hp

File details come from the government source that posted it. Updated .