B 08 - Amendment 01 - Questions with Answers.docx

DOCX document 22 KB Posted

Attached to
Aqueous Parts Washers
Solicitation number
W912LM-24-Q-0022
Issued by

About this file

This document is a set of questions and answers regarding Amendment 01 to a solicitation for Aqueous Parts Washers. The key details are:

The solicitation requires a minimum inside working height of 35 inches and a turntable diameter of 27 inches. It calls for both a 230V 1 or 3 phase power supply, with a 3HP pump motor. The automatic timers are for the heater shut off, not a separate wash timer. The original solicitation and Statement of Work provide full details on the requirements for the Aqueous Parts Washers.

View the file

Other files

File Type Posted
A 02 SOW Parts Washer.docx DOCX document
B 01 - Combined Synopsis_Solicitation - Parts Washers.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Parts Washer

Amendment 01

Below are questions received and answered regarding this solicitation.

1. Question: Can you define the actual working height that is required for both washers?

a. Response: Inside working height 35 inches minimum

2. Question: The call outs for: Bullet 12 “Automatic 7 Day/24-hour timer”, Bullet 14 “Heater Timer. Is the 14 to be a wash timer and the 12 a programmable timer for the heaters?

a. Response: correct in this statement, the timers are for the automatic shut off for the heaters

3. Specs call for both a 120v and a 208 v unit. It can not be both, and for a unit this size 120v will not provide the power. Can you verify 208v power?

a. Response: 230v 1 or 3 phase

4. “Turntable style cleaner with 700-1260 sq inch surface” That covers just about all of our units. The standard way to specify a size is by the diameter of the turntable in inches. Can you tell us what diameter you are requesting?

a. Response: Inside working height- 35”, turntable diameter- 27”

5. The pump says 5 hp but the flow says 150 gpm at 50 psi. You have to have a 7.5 hp pump to get that output.

a. Response: Pump motor size- 3hp

File details come from the government source that posted it. Updated .