207238 E801C.pdf
PDF 586 KB Posted
- Attached to
- Amendment 0004 to this Solicitation
- Solicitation number
- W912L709R0007
About this file
Plan E801C
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
w
X h
S
E C
T
IO
N A
L
O V
E R
H E
A D
D O
O R
GLASS
BLOCK
GLASS
BLOCK
GLASS
BLOCK
GLASS
BLOCK
MECH. LOUVER
D.S.
W/DRAIN
BOOT
(DRY)
SHOWER
(DRY)
DRINKING
FOUNTAINS
DRINKING
FOUNTAINS
w
X h
E C
T
IO
N
L
O V
E R
H E
A D
D O
O R
GLASS
BLOCK
GLASS
BLOCK
W/DRAIN
BOOT
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
H T
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/2
/2 g d g n \2
\2
E
C
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
2 Addendum No. 2 8-21-09
CORRIDOR
CORRIDOR
CLASSROOM #2
D110
ALCOVE
C118
F LOCKERS
C101
F TOILET
C102
F SHWR
C103
WALK-THRU CHASE
C104
M TOILET
C105
M LOCKER
C106
30TH HEATED
STOR 1000
C107
VAULT
C108
SPLY OFF
C109
C111
C110
1175TH HEATED
STOR 2312
C112
MECH RM #1
C113
FAC MAINT #2
C115
FM#10
C114
PHYSICAL
FITNESS
C116
M SHWR
C117
MECH #1
C113b
PLANTER
30TH HEATED
STOR 1000
C107
C108
C109
C111
C110
KEYPLAN
E 8.01c
TELECOMMUNICATIONS - FIRST FLOOR PLAN PART C
TELECOM-
MUNICATIONS
FIRST FLOOR
PLAN PART C
S
S
S
S
TV
S
S
S S
W
W
(1-1)
(1-1)
(1-1) (1-1)
(1-1)
(1-1)
(1-1)
(1-1)
(1-1)
(1-1)
1/8" = 1’-0"
TV
TV
LEGEND
TELEVISION LOCATION
PAGING HORN
VOICE ONLY LOCATION
DATA ONLY LOCATION
VOICE/DATA FLOORBOX LOCATION
J
TV
VGA VGA INTERFACE
CEILING SPEAKER
C
P PROJECTOR
CCTV CAMERA
VOICE / DATA LOCATION
JUNCTION BOX -2-1" CONDUITS
TO ABOVE CEILING
(1-1)NUMBER INDICATES QTY
OF VOICE CABLES
NUMBER INDICATES QTY
OF DATA CABLES
SLEEVE AND FIRESTOP
THROUGH WALL
A.
GENERAL NOTES:
J J
J
J
K J J
J
J
J
K 6
9 2
H
J J
K
J J
J
J
J
K
H
B.
C.
ROUTE ALL CABLING TO COMM ROOM AS SHOWN ON
SHEET E801A NOTE 1.
ELECTRICAL NOTES:
WIRING FOR IDS SYSTEM IS N.I.C. (NOT IN CONTRACT).
1. 4"x4" J-BOX FOR IDS EQUIPMENT (TYPICAL). IDS
EQUIPMENT IS N.I.C.
2. 1/2 " CONDUIT EXTEND 8" DOWN WALL.
3. 3/4 " CONDUIT UNDER SLAB TO TTB LOCATION IN
TELECOM 108.
4. 2" CONDUIT UNDER SLAB TO MDF LOCATION IN
TELECOM 108.
5.
6. 2"x4" BOX AT 60" A.F.F. FOR KEYPAD. (KEYPAD
EQUIPMENT N.I.C.)
7.
8.
9.
J-BOX FOR HORN AT 10’-0" A.F.F. (HORN
EQUIPMENT N.I.C.)
J-BOX ABOVE DOOR 10’-0" A.F.F.
6 EA. 3/4 " CONDUIT THROUGH CEILING 4" CLEAR
BETWEEN EA. TERMINATE AT 5’-8" A.F.F.
4’x4’x 3/4 " CDX PLYWOOD PAINTED BACKBOARD.
TOP AT 6’-0" A.F.F.
1/8" = 1’-0"
2 8-20-09
TV
W 2
IDS CONDUIT LAYOUT FOR VAULT AREAS
ALL IDS VAULT CONDUIT 3/4 " U.O.N.
File details come from the government source that posted it. Updated .