Text version
UP
U P
U P
UP
D.S.
W/DRAIN
BOOT
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
H T
A L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/2
/2 g d g n \2
\2
E
D
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
2 Addendum No. 2 8-21-09
FAMILY
SPT
D102
30TH TC
ENTRANCE
D101
30TH HHC
ADMIN
D104
FAC
MAINT #8
D103
FAC
MAINT #7
D105
TELCOM
D106
RNCO
D108
STAIRS
CORRIDOR
TOIL
D107
C O
R R
ID
O
R
D
BREAK #2
D113
CLASSROOM #2
D110
CO 1SG
D112
CO CDR
D111
SIPRNET
D114
AST OPS
NCO
D115
AST OPS
NCO
D116
BDE S3
SECTION
D117
BDE S3
D118
OPS SGM
D119
D120
BDE S2
SECTION
D123
BDE S2
NCO
D122
CONF.
ROOM
D121
SPECIAL
STAFF
D124
R R
ID
O
R
D
SPECIAL
STAFF
D127
BDE S2
D125
STAFF
OFF
D128
BDE S6
D132
C O
M S
E C
S T
O R
D
BDE S6
NCO
D133
BDE STAFF
SECTION
D129
BDE STAFF
SECTION
D130
STAFF
OFF
D134
R R
ID
O
R
D
SR SPLY
NCO
D136
AST S4
D137
BDE S4
SECTION
D138
BDE S4 m
D139
BDE S1 m
D140
HALL
D141
S4 NCO
D142
S1 NCO
D143
BDE S1
SECTION
D146
PER SRV
NCO
D144
SNR PER
TECH
D145
BDE CSM
D147
BDE CDR
D148
WAR RM
D149
F LOCKERS
C101
FAC MAINT #2
C115
FM#10
C114
PLANTER
KEYPLAN
E 2.01d
POWER - FIRST FLOOR PLAN PART D
L
SD
SD
SD
F
F S
L
L
L
FS
FS
FS
L
L
F S
FS
L
FL
SD
FS
L
L
FS
FS
L
FS
F S
F S
FS FS
L
L
L
FS
J
L
FS FS
L
L
FS
J
L
F S
FS
FS
L
L2-42
EQL-48
L2-40
L2-55
L2-43
L2-61 L2-59
L2-63
EQL-34
L2-34
L2-30
L2-32
L2-18
L2-16
L2-28
L2-24
L2-22
L2-45
L2-20
EQL-28
EQL-30
EQL-32
L2-6
L2-47
L2-14
L2-12
L2-10 L2-8
L2-41
L2-37
L2-31
L2-35 L2-33
L2-39
L2-29
L2-25
L2-27
POWER &
SYSTEMS -
FIRST FLOOR
PLAN PART D
L2-36
L2-38
EQL-36
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
JUNCTION BOX AND SWITCH TO SERVE MOTORIZED SCREEN.
COORDINATE EXACT ROUGH-IN REQUIREMENTS WITH EQUIPMENT
VENDOR.
J
L2-21,23
L2-57
J1
L2-65
J
S
CLG
L2-53
TV
L2-4
TV
TV
L2-69
L2-2
CLG
L2-51
J
S
L2-26
L2-49
CLG
J S
L2-15
TV
EQL-53
1/8" = 1’-0"
WP
WP
EQL-78J
2. JUNCTION BOX TO SERVE SEMI-RECESSED AUTOMATIC EXTERNAL
DEFIBRILLATOR CABINET.
TV
TV TV
TV TV
TV
TV
TV
TV
L2-75
TV
TV
L2-77
TV
TV
TV
TV
TV
TV
L2-79
TV
TV
TV
TV
L2-81
NEMA
L6-30
EQL-80,82
2 #10,1 #10G, 3/4 "C.
EQL-84,86
2 #10,1 #10G, 3/4 "C.
PROVIDE 12"x 1/4 "x2" DEDICATE COPPER GROUND BAR WITH #2/0
COPPER GROUND WIRE HOMERUN TO BAR ON PANEL ’MDP’.
RECEPTACLE LOCATED IN CEILING.
3.
4.
L2-67
TV TV