2007042 ADD1 E Supplemental Dwgs 081109.pdf
PDF 6 MB Posted
- Attached to
- Amendment 0004 to this Solicitation
- Solicitation number
- W912L709R0007
About this file
E Supplemental Dwgs
View the file
Other files
Show 40 more
Latest 50 of 64 listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
A N
D E
R S
O N
GRAVEL DRIVE
F M
-8"
FM-8"
W-10" W-10"
O H
FFE 1054.5
U G
E
U G
E
T E
L E
T E L E
T E
L E
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
H T
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2
G d g n \2
\2
E
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
T E
L E
T E
L E
U G
E U
G E
D Y H
D Y H
D Y H D Y
H
E 0.01
ELECTRICAL - SITE PLAN
1"=50"-0"
ELECTRICAL -
SITE PLAN
UTILITY PAD-MOUNT
TRANSFORMER
EMERGENCY
GENERATOR
UTILITY RISER
POLE
’B’
’B’ ’B’
’B’
’C’
’C’
’C’
’C’
’C’
ELECTRICAL NOTES:
1.
2.
3.
H1-57
’C’
H1-55
H1-59
H1-61
J
L1-59
H1-63
A
A
B
B
4.
5. CIRCUIT VIA LIGHTING CONTACTOR ’LC2’.
CIRCUIT VIA LIGHTING CONTACTOR ’LC1’.
GENERAL NOTES:
A. CONTRACTOR TO PAY ALL COSTS AND FEES (CAPACITY, TAP,
INSPECTION, ETC.) ASSOCIATED WITH UTILITY SERVICES.
B. MULTI-WIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC
210.4.
C. UNLESS OTHERWISE NOTED, 20A/1P BREAKERS SHALL UTILIZE
#12 AWG CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS
IN EXCESS OF 90 LINEAR FEET, CONDUCTORS SHALL BE #10
AWG, AND WHERE BRANCH CIRCUIT IS IN EXCESS OF 175 LINEAR
FEET, CONDUCTORS SHALL BE #8 AWG. EQUIPMENT GROUNDING
CONDUCTOR SHALL MATCH PHASE CONDUCTOR SIZE FOR 20A/1P
BRANCH CIRCUITS.
FLAG POLE
’H’ ’H’
H1-65
D D
TS
TS
J
L1-83
HOT BOX
INSTALLATION OF EMERGENCY GENERATOR SHALL BE OPTION #2.
PROVIDE TEMPORARY GENERATOR QUICK-CONNECT BOX AT THIS LOCATION
AS THE BASE BID IF OPTION #2 IS NOT ACCEPTED.
E E
C C
36" TOP
TO FIN.
GRADE
4’ BELOW
GRADE
18"
DIA.
CONCRETE
3,000 P.S.I.
CONDUIT(S)
4 #6 VERT. W/#3
TIES 12" O.C. (AS
REQ’D.)
ANCHOR BOLTS
NO SCALE
POLE BASE DETAIL
18" DIAMETER
PROVIDE
3’ BELOW
GRADE
TO MATCH
POLE
CAST BOX & GASKET (BEHIND
BRACKET)
FINISHED GRADE
1" CHAMFER
NO SCALE
TO NEXT
FIXTURE
TYPE
FIXTURE
FIELD ADJUST AS REQ’D.
TO LIGHT INTENDED AREA
TO ARCHITECTS SATISFACTION
18" x 18" x 18" REINFORCED
3000 P.S.I. CONCRETE BASE
BY GENERAL CONTRACTOR
SEAL-TITE
FLAG POLE
OR WALL
FIXTURE TYPE ’H’ GND. MTD. FLOOD
FIXTURE MOUNTING DETAIL
ANCHOR BOLTS FURNISHED
AND INSTALLED BY
ELECTRICAL CONTRACTOR
’A2’
’A2’
’A1’
’A2’ ’A2’
’A1’
’A1’
PROVIDE POWER AS SHOWN AND AN ADDITIONAL 3/4 "C. FOR LOW VOLTAGE
WIRING TO GATE OPERATOR.
6. PROVIDE 3/4 "C ROUGH-IN FOR GATE OPERATOR KEYPAD ON PEDESTAL.
COORDINATE WITH VENDOR FOR EXACT ROUGH-IN LOCATIONS. PROVIDE
ADDITIONAL 3/4 " CONDUIT ROUGH-IN TO DETECTOR LOOP UNDER PAVEMENT.
UP
U P
U P
UP
D.S.
W/DRAIN
BOOT
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
D
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
FAMILY
SPT
D102
30TH TC
ENTRANCE
D101
30TH HHC
ADMIN
D104
FAC
MAINT #8
D103
FAC
MAINT #7
D105
TELCOM
D106
RNCO
D108
STAIRS
CORRIDOR
TOIL
D107
C O
R R
ID
O
R
D
BREAK #2
D113
CLASSROOM #2
D110
CO 1SG
D112
CO CDR
D111
SIPRNET
D114
AST OPS
NCO
D115
AST OPS
NCO
D116
BDE S3
SECTION
D117
BDE S3
D118
OPS SGM
D119
D120
BDE S2
SECTION
D123
BDE S2
NCO
D122
CONF.
ROOM
D121
SPECIAL
STAFF
D124
R R
ID
O
R
D
SPECIAL
D127
BDE S2
D125
STAFF
OFF
D128
BDE S6
D132
C O
M S
E C
S T
O R
D
BDE S6
NCO
D133
BDE STAFF
SECTION
D129
BDE STAFF
SECTION
D130
STAFF
D134
R R
ID
O
R
D
SR SPLY
NCO
D136
AST S4
D137
BDE S4
D138
BDE S4 m
D139
BDE S1 m
D140
HALL
D141
S4 NCO
D142
S1 NCO
D143
BDE S1
SECTION
D146
PER SRV
NCO
D144
SNR PER
TECH
D145
BDE CSM
D147
BDE CDR
D148
WAR RM
D149
F LOCKERS
C101
FAC MAINT #2
C115
FM#10
C114
PLANTER
KEYPLAN
E 1.01d
LIGHTING - FIRST FLOOR PLAN PART D
LIGHTING -
FIRST FLOOR
PLAN PART D
5 5
5 5
5 5
5 5
5555555 5 5 5 5
5 5
5 5 5
5 5
5 5
5 5
5 5
5 5
555555
5 5
5 5
5 5
5 5
5 5 5 5 5 5
555555
’6’ ’6’ ’6’
’6’’6’
’6E’ ’6E’’6’
’6’ ’6’
’6’
’6’
’6’
’6E’
’6’
’6’
’1’
’1’
’1’
’9E’
’1’
’1’
’12’ ’12’ ’12’ ’12’ ’12’ ’12’ ’12’
’6’ ’6’ ’6’ ’6’
’F2’ ’F2’ ’F2’ ’F2’ ’F2’
3S
S
S
3S
S
S SMSM
S M
SM
S S
S
S S
S
S S
S
S
S
S
S
S
S4
3S
3S
3S
S S
S S
S S
S
S S
S
S
S
S
S
S
S4
EQH-18
H2-8
S
H2-4
S
DT
OS
IR
OS
IR
OS
IR
OS
IR
OS
DT
OS
IR
OS
IR
OS
U
OS
IR
OS
IR
OS
IR
OS
U
OS
IR
OS
IR
OS
IR
OS
IR
OS
IR
OS
U
OS
IR
OS
U
OS
IR
OS
IR
OS
IR
OS
IR
OS
U
OS
IR
OS
IR
OS
IR
OS
IR
OS
IR
OS
IR
OS
IR
OS
IR
OS
U
OS
H2-2
NL NL
NL NL NL NL NL NL NL
NL
NL
NL
’12E’ ’12E’ ’12E’ ’12E’
’12E’ ’12E’ ’12E’ ’12E’
’6E’
’6E’
’5E’ ’5E’
NL NL
’5E’
NL
’5E’
NL
’5E’
’5E’
’5E’
’5E’
’5E’’5E’
’5E’
’5E’
’5E’
’5E’
H1-4
’9E’
’9E’
NL
NL
NL
A.
GENERAL NOTES:
B.
DEVICES INDICATED ON THIS DRAWING ARE DIAGRAMMATICAL ONLY.
CONTRACTOR SHALL REFER TO ARCHITECTURAL ELEVATIONS FOR
EXACT LOCATIONS OF OUTLETS, SWITCHES, ETC.
C. CIRCUIT ALL EMERGENCY BALLASTS AHEAD OF SWITCHING.
D.
E. EMERGENCY EGRESS LIGHTING FIXTURES, INDICATED WITH ’NL’
DESIGNATION, SHALL BE CIRCUITED UNSWITCHED.
UNLESS OTHERWISE NOTED, 20A/1P BREAKERS SHALL UTILIZE
#12 AWG CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT
IS IN EXCESS OF 90 LINEAR FEET, CONDUCTORS SHALL BE #10
AWG, WHERE BRANCH CIRCUIT IS IN EXCESS OF 175 LINEAR FEET,
CONDUCTORS SHALL BE #8 AWG, AND WHERE BRANCH CIRCUIT
IS IN EXCESS OF 260 LINEAR FEET, CONDUCTORS SHALL BE #6 AWG.
COORDINATE EXACT LOCATIONS OF LIGHTING FIXTURES WITH
STRUCTURAL FRAMEWORK, MECHANICAL DUCTWORK AND EQUIPMENT
PRIOR TO ROUGH-IN.
H2-6
H2-10
5 5
1.
ELECTRICAL NOTES:
CIRCUIT VIA LIGHTING CONTACTOR ’LC1’.
1/8" = 1’-0"
’5E’ ’5E’
S
DT
OS
U
PU
P
8’4"x5’9"
SHAFT MIN
5’ DEEP
SUMP PIT
UP
UP
U P U
P
UP
D.S.
W/DRAIN
BOOT
D.S.
W/DRAIN
BOOT
8’4"x5’9"
SHAFT MIN
5’ DEEP
SUMP PIT
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
A
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
FRONT
ENTRY
FOYER
FAMILY
SPT
D102
30TH TC
ENTRANCE
D101
30TH HHC
ADMIN
D104
LOBBY
(OPEN TO ABOVE)
1175TH
ENTRANCE
A101
MAINT #8
FAC
LOBBY
1175TH
ADMIN
A104
RECRUIT
A102
FAC
MAINT#6
A103
FAC
MAINT#5
A105
A106
TOIL.
A107
R R
ID
O
R
A
1175TH ADMIN
M DAY AREA
A108
BREAK #1
A110
OFFICE
A111
A112
A113
CLASSROOM #1
A114
A116
ELEV EQ
A115
FAC
MAINT #1
B112
1175TH ADMIN
M DAY AREA
A117
B113a
PLANTER
B113b
PLANTER
A
ELEV EQ
A115
KEYPLAN
E 2.01a
POWER - FIRST FLOOR PLAN PART A
L
L
FS
FS
FS
FS
J
L
F
F S
SD
SD
SD
F
L
FS
L
L
L
L L L
L
L
L
FS
FS
FS
FS
FS
SD E
SD SD
1/8" = 1’-0"
L1-3
L1-5
L1-7
L1-19
L1-9
L1-13
L1-17
L1-29
L1-31 L1-33
L1-27
L1-21
POWER &
SYSTEMS -
FIRST FLOOR
PLAN PART A
3#12,1#12G, 3/4 "C
EQH-
32,34,36
NEMA
16-20R
EQL-42 EQL-44
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
JUNCTION BOX AND SWITCH TO SERVE MOTORIZED SCREEN. COORDINATE
EXACT ROUGH-IN REQUIREMENTS WITH EQUIPMENT VENDOR.
FAA
TV
J S
CLG
L1-37
TV
L1-35
J
L1-23,25
L1-1
TVJ
L1-63,65
L1-67
F S
TS
TS
EQL-46
EQL-47
EQL-49
EQL-51
WP
EQL-8
HD
HD
SD
ENLARGED ELEVATOR PLAN
1/4" = 1’-0"
3/4 "C. HOMERUN TO COMMUNICATIONS TERMINAL BOARD WITH
3/4 "C. TO ELEVATOR CAB FOR COMMUNICATIONS.
TO ELEVATOR CAB LIGHTING.
PROVIDE 150 WATT INCANDESCENT SERVICE LIGHTING FIXTURE
WITH WIRE GUARD, HUBBELL #VWX-151-VCG-15 OR EQUIVALENT.
MOUNT SWITCH ADJACENT TO LADDER.
2.
3.
4.
5.
100/3/FAR
30/2/F20
J
S
L1-4
L1-6
L1-8
3 #4, 1 #8G., 1"C.
MDP-11
6. JUNCTION BOX TO SERVE SEMI-RECESSED AUTOMATIC EXTERNAL
DEFIBRILLATOR CABINET.
J
MECH. LOUVER
GLASS
BLOCK
GLASS
BLOCK
GLASS
BLOCK
GLASS
16’w X 14’h
SECTIONAL
OVERHEAD DOOR
D.S.
W/DRAIN
BOOT
D.S.
W/DRAIN
BOOT
DRINKING
FOUNTAINS
RECYCLE BINS
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
B
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
ASSEMBLY
CLASSROOM #1
ALCOVE
C118
FAC MAINT #4
B104
BREAK #3
B101
FAC
MT #3
B103
B105
B106
KITCHEN
B107
CIRCULATION
B108
SCULLERY
B110 DISH
DROP
B109
FAC
MAINT #1
TABLE
STOR
B111
SPLY OFF
C109
C110
SPKLR
B113a
ELEC. RM #2
B102
WATER HEATER
B113b
ELEC.
RM #1
B113c
PLANTER
KEYPLAN
2.01b
POWER - FIRST FLOOR PLAN PART B
SD
SD
SD
SD
FS
FS
FS
SD
F S
L
L
L
L
L
F S
SD
’MDP’
T
’L1’
’H1’
ATS
’EQ’
T
’EQL’
L1-14
L1-16
L1-18
L1-20
EQL-22
EQL-18
POWER &
SYSTEMS -
FIRST FLOOR
PLAN PART B
EQL-10
EQL-12
EQL-16
EQL-14
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
JUNCTION BOX TO SERVE AUTOMATIC SHADES IN CLERESTORY ABOVE.
PROVIDE ROUGH-IN TO CONTROL POINT TO BE LOCATED ADJACENT TO
LIGHTING SWITCHES IN THIS AREA (REFER TO SHEET E1.01b). COORDINATE
EXACT ROUGH-IN REQUIREMENTS WITH EQUIPMENT VENDOR.
J
J1
EQL-56
J
F S
J
EQL-54
TS FL PS
1/8" = 1’-0"
WP
’EQH’
L1-69
L1-71
L1-75
L1-73
J
2. JUNCTION BOX TO SERVE SEMI-RECESSED AUTOMATIC EXTERNAL
DEFIBRILLATOR CABINET.
w
X h
S
C
T
IO
N
L
V
E R
H E
A D
D O
O R
GLASS
BLOCK
GLASS
BLOCK
GLASS
BLOCK
GLASS
D.S.
W/DRAIN
BOOT
(DRY)
SHOWER
(DRY)
DRINKING
FOUNTAINS
DRINKING
FOUNTAINS
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
C
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
ALCOVE
C118
F TOILET
C102
F SHWR
C103
WALK-THRU CHASE
C104
M TOILET
C105
M LOCKER
C106
30TH HEATED
STOR 1000
C107
VAULT
C108
C109
VAULT
C111
C110
1175TH HEATED
STOR 2312
C112
MECH RM #1
C113
PHYSICAL
FITNESS
C116
M SHWR
C117
MECH #1
C113b
PLANTER
KEYPLAN
E 2.01c
POWER - FIRST FLOOR PLAN PART C
F S
SDSD
SD SD
F S
F
F
L
L
FS FS
FS
F S
F S
F S
FS
L
L
FS
SD
SD
SDSD
L
F
F S
F S
REFER TO VAULT SCHEMATIC FOR ADDITIONAL WORK IN THIS AREA.
T
’L2’ ’H2’
FACP
EMCS
CONTROLLER
L2-11
L2-17
L2-7
L2-9
EQL-24
EQL-26
L2-5
L2-3
L2-19
L2-1
POWER &
SYSTEMS -
FIRST FLOOR
PLAN PART C
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
TV
L2-13
F S
SD
1/8" = 1’-0"
WP
L2-66
WP
TO RECEPTACLE ON ROOF (SEE SHEET E3.01C).2.
L2-86
U P
U P
UP
D.S.
W/DRAIN
BOOT
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
D
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
FAMILY
SPT
D102
30TH TC
ENTRANCE
D101
30TH HHC
ADMIN
D104
FAC
MAINT #8
D103
FAC
D106
D108
D107
R R
ID
O
R
D
BREAK #2
D113
D112
D111
SIPRNET
D114
AST OPS
NCO
D115
AST OPS
NCO
D116
BDE S3
D117
BDE S3
D118
OPS SGM
D119
D120
BDE S2
SECTION
D123
BDE S2
NCO
D122
CONF.
ROOM
D121
SPECIAL
D124
R R
ID
O
R
D
SPECIAL
D127
BDE S2
D125
STAFF
D128
BDE S6
D132
C O
M S
E C
S T
O R
D
BDE S6
NCO
D133
BDE STAFF
SECTION
D129
BDE STAFF
SECTION
D130
STAFF
D134
R R
ID
O
R
D
SR SPLY
NCO
D136
AST S4
D137
BDE S4
D138
BDE S4 m
D139
BDE S1 m
D140
D141
S4 NCO
D142
S1 NCO
D143
BDE S1
SECTION
D146
PER SRV
NCO
D144
SNR PER
TECH
D145
BDE CSM
D147
BDE CDR
D148
WAR RM
D149
PLANTER
KEYPLAN
E 2.01d
POWER - FIRST FLOOR PLAN PART D
L
SD
SD
SD
F
F S
L
L
L
FS
FS
FS
L
L
F S
FS
L
FL
SD
FS
L
L
FS
FS
L
FS
F S
F S
FS FS
L
L
L
FS
J
L
FS FS
L
L
FS
J
L
F S
FS
FS
L
L2-42
EQL-48
L2-40
L2-55
L2-43
L2-61 L2-59
L2-63
EQL-34
L2-34
L2-30
L2-32
L2-18
L2-16
L2-28
L2-24
L2-22
L2-45
L2-20
EQL-28
EQL-30
EQL-32
L2-6
L2-47
L2-14
L2-12
L2-10 L2-8
L2-41
L2-37
L2-31
L2-35 L2-33
L2-39
L2-29
L2-25
L2-27
POWER &
SYSTEMS -
FIRST FLOOR
PLAN PART D
L2-36
L2-38
EQL-36
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
JUNCTION BOX AND SWITCH TO SERVE MOTORIZED SCREEN.
COORDINATE EXACT ROUGH-IN REQUIREMENTS WITH EQUIPMENT
VENDOR.
J
L2-21,23
L2-57
J1
L2-65
J
S
CLG
L2-53
TV
L2-4
TV
TV
L2-69
L2-2
CLG
L2-51
J
S
L2-26
L2-49
CLG
J S
L2-15
TV
L2-67
TV TV
EQL-53
EQL-74
1/8" = 1’-0"
WP
WP
EQL-78J
2. JUNCTION BOX TO SERVE SEMI-RECESSED AUTOMATIC EXTERNAL
DEFIBRILLATOR CABINET.
TOOL
ROOM
SUPPLY
ROOM
MAINT
WORK BAY
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
2.03
T ’L3’
F
F S
F S
F F
J J
F S
L3-1
POWER &
SYSTEMS-
VEHICLE MAINT
BLDG FLOOR
PLAN
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
4’x8’x 3/4 " PLYWOOD TELEPHONE BACKBOARD PAINTED WITH FIRE
RETARDANT GRAY PAINT.
L3-8
POWER -
VEHICLE MAINT BLDG FLOOR PLAN
2. PROVIDE RECEPTACLE AND FIXTURE ON CORD REEL. REEL
SHALL BE MOUNTED AT 8’ AFF
3. RECEPTACLE SHALL BE MOUNTED AT 5’ AFF.
4. PROVIDE ROUGH-IN AS NECESSARY FOR OVERHEAD DOOR CONTROLS.
GFI GFI GFI GFI GFI GFI2 2
3 3 3 3 3 3
4 4
GFI
GFI GFI GFI
WELDER WELDER
WP
WP
L3-13 L3-27
L3-11 L3-29
L3-9
L3-7
L3-3
L3-5
PLASMA
CUTTER
3 #1, 1 #6G.
1 1/4 "C.
L3-37,39,41
L3-21,23,25
L3-22,24
3 #12, 1 #12G.
3/4 "C.
4 #4, 1 #8G.
1 1/4 "C.
4 #2, 1 #8G.
1 1/4 "C.
L3-16, 18,20
L3-26, 28,30
3 #4, 1 #8G.
1"C.
BATTERY
CART
CRANE
PARTS
WASHER
AIR
COMPRESSOR
3 #1, 1 #6G.
1 1/4 "C.
L3-31,33,35
3 #12, 1 #12G.
3/4 "C.
L3-15,17,19
L3-32,34,36
4 #2, 1 #8G.
1 1/4 "C.
L3-10,12,14
1/8" = 1’-0"
5. JUNCTION BOX TO SERVE SEMI-RECESSED AUTOMATIC EXTERNAL
DEFIBRILLATOR CABINET.
J
TOOL
ROOM
SUPPLY
ROOM
MAINT
WORK BAY
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
MOD
VF
MODMODMOD
VF
PTAC
EF
EF
GIH
GIH
GIH
GIH
EH
EH
MECHANICAL EQUIPMENT -
VEHICLE MAINT BLDG FLOOR PLAN
MECHANICAL
EQUIPMENT -
VEHICLE MAINT
BLDG FLOOR
PLAN
3.03
M M M
M
1 1 1
ST
L3-57
ST
L3-47 ST
L3-51
ST
L3-55
ST
ST
L3-65
ST
ST
ST
L3-61
ST
L3-59
ST
L3-67
L3-43
NOTES:
1. CIRCUIT ALL MOTORIZED DAMPERS TO CIRCUIT L3-63.
1/8" = 1’-0"
WP WP
TO CIRCUIT L3-1
IN SUPPLY RM.
303 (SEE SHEET E2.03)
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
E 6.00
ABBREVIATIONS
AFF
AFG
ABV
ABC
EDF
FBE
FBO
GND
UON
WH
ABOVE FINISHED FLOOR
ABOVE FINISHED GRADE
ABOVE CEILING
MOUNT ABOVE COUNTER
ELECTRIC DRINKING FOUNTAIN
FURNISHED & INSTALLED BY ELECTRICAL CONTRACTOR
FURNISHED BY OTHERS, INSTALLED BY ELECTRICAL CONTRACTOR
GROUND
UNLESS OTHERWISE NOTED
WATER HEATER
WP WEATHER PROOF, NEMA 3R
FIRE ALARM SYSTEM
MANUAL PULL STATION
DUCT-SMOKE DETECTOR (DAMPER) OR (EXHAUST)
AUTOMATIC HEAT DETECTOR (RATE OF RISE TYPE)
SYSTEM CONNECTED SMOKE DETECTOR
SYSTEM CONNECTED SMOKE DETECTOR FOR FIREMAN’S RECALL
SMOKE DOOR HOLDER
TAMPER SWITCH
FLOW SWITCH
CONTROL PANEL
PULL CABINET
REMOTE ANNUNCIATOR
FIRESTAT
CENTRAL PROCESSING UNIT
COMMAND CENTER
TRANSPONDER
END OF LINE DEVICE
CEILING
CEILING
CEILING
6’-0"
F
DSD
HD
SD
SD E
DH
TS
FL
FACP
FAPC
FAA
FR
FAPU
FACC
FAST
E.O.L.
CONDUIT EXPOSED ON WALL OR CEILING
HOMERUN CONDUIT, 2 CIRCUIT 3#12 AWG
CONDUIT TURNING UP
CONDUIT TURNING DOWN
SURFACE MOUNTED INCANDESCENT OR HID LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT
RECESSED INCANDESCENT OR HID LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT
RECESSED INCANDESCENT OR HID LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT
SURFACE MOUNTED WALL INCANDESCENT OR HID LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT
SURFACE MOUNTED WALL INCANDESCENT OR HID LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT
RECESSED WALL INCANDESCENT OR HID LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT
SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT
RECESSED FLUORESCENT LIGHT FIXTURE ON NORMAL BRANCH CIRCUIT
RECESSED FLUORESCENT LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT
AS NOTED
AS NOTED
WALL BRACKET FLUORESCENT FIXTURE CONNECTED TO NORMAL BRANCH CIRCUIT
WALL BRACKET FLUORESCENT FIXTURE CONNECTED TO EMERGENCY BRANCH CIRCUIT
EXIT LIGHT, CEILING MOUNTED
EXIT LIGHT, WALL MOUNTED
TWO HEAD BATTERY POWERED EMERGENCY EGRESS LIGHT
REMOTE EMERGENCY BATTERY PACK
LIGHTING FIXTURE TYPE DESIGNATION-SEE LIGHTING FIXTURE SCHEDULE
EBP
"5"
AREA OR STREET LIGHT FIXTURE
WH
J
PB
WATER HEATER
JUNCTION BOX
PULL BOX
ENCLOSED CIRCUIT BREAKER
THERMAL MOTOR SWITCH-(FBE)
THERMAL MOTOR SWITCH, WEATHERPROOF-(FBE)
THERMAL MOTOR SWITCH, WITH PILOT LIGHT (FBE)
KEY OPERATED SWITCH
SINGLE POLE SWITCH WITH PILOT LIGHT
SINGLE POLE SWITCH, WEATHERPROOF
SINGLE POLE, DOUBLE THROW, CENTER OFF SWITCH (DARK ROOM)
S
S2
3S
S4
SD
ST
STWP
STP
SK
SP
SWP
SPD
46"
18"
18"
AS SPECIFIED
18"
AS SPECIFIED
AS SPECIFIED
AS SPECIFIED
18"
18"
TV
SINGLE RECEPTACLE, AMPERAGE, VOLTAGE, NEMA CONFIGURATION AS REQUIRED BY EQUIP. SUPPLIER OR AS NOTED
S
S
T
WP
SINGLE RECEPTACLE-TWISTLOCK TYPE (120V.-20A. UNLESS OTHERWISE SPECIFIED)
GROUND FAULT RECEPTACLE WEATHERPROOF
SR
R
IG
IG
TWO GANG FLOOR BOX WITH ONE DUPLEX RECEPTACLE AND ONE TELEPHONE OUTLET
DUPLEX RECEPTACLE 20 AMP 120 VOLT
120V. DUPLEX FOR RADIO EQUIPMENT POWER
QUADRAPLEX RECEPTACLE, ISOLATED GROUNDING
DUPLEX RECEPTACLE, ISOLATED GROUNDING, INSTALL ABOVE COUNTER
DUPLEX RECEPTACLE, ISOLATED GROUNDING,
DUPLEX RECEPTACLE AND SINGLE POLE SWITCH UNDER COMMON PLATE
WP WEATHERPROOF DUPLEX RECEPTACLE
PLUGMOLD #3000 WITH HUBBELL 5252 DUPLEX RECEPTACLES 24" ON CENTER
PLUGMOLD #2100 WITH 2121 GA RECEPTACLES 24" ON CENTER
FLOOR BOX
FLOOR BOX
18"
18"
18"
18"
46"
46"
46"
SYMBOL DESCRIPTION
ELECTRICAL LEGEND
MOUNTING
HEIGHT
TO CENTERLINE
UON
SYMBOL DESCRIPTION
COMMUNICATIONS LEGEND
MOUNTING
HEIGHT
TO CENTERLINE
A.F.F. UON
DUPLEX RECEPTACLE 20 AMP 120 VOLT-(MOUNTED ABOVE COUNTER) 46"
IG
46"
46"
46"
46"
46"
46"
46"
46"
46"
46"
46"
C
M
FIRE ALARM CONTROL MODULE, ADDRESSABLE
FIRE ALARM MONITOR MODULE, ADDRESSABLE
AS NOTED6" TO CENTERLINE BELOW FINISH CEILING
PANELBOARD
SURFACE MOUNTED FLUORESCENT LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT
RECESSED WALL INCANDESCENT OR HID LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT
SURFACE MOUNTED INCANDESCENT OR HID LIGHT FIXTURE ON EMERGENCY BRANCH CIRCUIT
AS SPECIFIED
CONDUIT CONCEALED BELOW GRADE ON SITE PLAN
CONDUIT CONCEALED IN FLOOR, WALL OR CEILING
L FLASHING LIGHT STATION
CEILING
F FIRE ALARM CLOSURE-AUDIO SYSTEM CONTROL
PTZ PAN-TILT-ZOOM
BD SMOKE DETECTOR BEAM TYPE AS NOTED
FIREMAN’S JACK
SPEAKER/FLASHING LIGHT COMBINATION
FS FIRE SPEAKER WALL
80"
46"
80"
MOD MOTOR OPERATED DAMPER-THERMAL MOTOR SWITCH (FBE)
FJ
(ALL SYMBOLS MAY NOT BE USED)(ALL SYMBOLS MAY NOT BE USED)
E EMERGENCY
SINGLE POLE DIMMER SWITCH, SEE SPECS.
S
F
F SPEAKER/FLASHING LIGHT COMBINATIONS
CLG CEILING
CEILING
DL DALI LOOP CONNECTION
L HORN/FLASHING LIGHT COMBINATION
FS FIRE SPEAKER
EDS ELECTRIC DOOR STRIKE
CEILING
FSD
SD
FIRE/SMOKE DAMPER
SMOKE DAMPER
FACTORY WIRED CONTROLLER OR EQUIPMENT CONNECTION, FBO.(DISCONNECTS FBE AS REQUIRED)
MOTOR CONTROLLER OR CONTACTOR
COMBINATION MOTOR STARTER DISCONNECT
DISCONNECT SWITCH, NON-FUSIBLE
DISCONNECT SWITCH, FUSIBLE
MOTOR CONNECTION WITH APPROXIMATE HORSE-POWER SHOWN
T
SV
PE
TC
PHOTO-ELECTRIC SWITCH
SOLENOID VALVE
ON-OFF TIME CLOCK
THERMOSTAT (FBO) SEE MECHANICAL
R
T
RELAY
TRANSFORMER
OCCUPANCY SENSORS
SM 46"
OS IR CEILING
OS U CEILING
OS DT CEILING
IR WALL SWITCH - WATTSTOPPER #PW-200 **
IR CEILING SENSOR - WATTSTOPPER #CX-100 **
ULTRASONIC CEILING SENSOR 2200 SQ. FT. - WATTSTOPPER #WT-2200 **
DUAL TECHNOLOGY CEILING SENSOR - WATTSTOPPER #DT-200 **
Final determination of circuiting, voltage and quantity of power packs required, and setting of sensitivity/time adjustments are the responsibility of the installing contractor. Manufacturer’s installation instructions should be adhered to.
1. All sensor locations are approximate. Refer to manufacturer’s installation instructions prior to installation. If pendant mounted fixtures are present, location and coverage of sensors should be reviewed.
2. Ultrasonic ceiling mount sensors require they be located no closer than 6’ to air supply/ return registers. Field locate as necessary.
3. Contractor is responsible for proper sensitivity and time delay settings, verification of manufacturer’s recommended placement, and field verification of circuits with respect to power pack placement.
4. Contractor is responsible for field verification of required number of power packs.
A. One power pack is required for each circuit that is to be controlled.
B. Maximum number of sensors that can be wired in parallel to a single power pack is dependent on sensor model (see individual data sheets for mA consumption).
OCCUPANCY SENSOR NOTES
** - SEE "OCCUPANCY SENSOR NOTES" THIS SHEET
SINGLE POLE SWITCH
TWO POLE SWITCH
THREE-WAY SWITCH
FOUR WAY SWITCH
120V. DUPLEX RECEPTACLE
120V. DUPLEX RECEPTACLE ABOVE COUNTER
120V. DUPLEX RECEPTACLE FOR TV POWER
120V. QUADRAPLEX RECEPTACLE
120V. QUADRAPLEX RECEPTACLE
120V. DUPLEX RECEPTACLE-SAFETY TYPE
120V. DUPLEX RECEPTACLE-SAFETY TYPE
GROUND FAULT TYPE RECEPTACLE
120V. SQUARE OR ROUND FLOOR BOX WITH (1) DUPLEX RECEPTACLE
PUSHBUTTON
IG ISOLATED GROUND
FIXTURE SCHEDULE
TYPE MANUFACTURER MOUNT REMARKS
CATALOG
NUMBER
NUMBER &
SIZE LAMPS
1X4 STRIP W/ WIREGUARD
CFL DOWNLIGHT
B
2-LAMP ACRYIIC LENS TOFFER
3-LAMP ACRYLIC LENS TROFFER
4-LAMP ACRYLIC LENS TROFFER
RECESSED DIRECT/ INDIRECT FLUOR.
ENCLOSED FLUOR. STRIP WET LOCATION
STAIRWELL WALL BRACKET
FLUOR. HIGH-BAY
CORR. CYLINDER
SINGLE-HEAD 1000W MH ON 40’ POLE
CFL HIGH-ABUSE SCONCE
11A
11B
HID INDIRECT WALL-MNTD UPLIGHT
FLUOR. INDIRECT WALL-MNTD UPLIGHT
D
F1
F2
G
HID EXTERIOR DOWNLIGHT
DECORATIVE WALL SCONCE W/ UP & DOWNLIGHT
DECORATIVE WALL SCONCE W/ DOWNLIGHT ONLY
EXTERIOR HID INDIRECT
ORGATECH
ORGATECH
SURFACE2-32W T8
RECESSED2-32W T8
RECESSED3-32W T8
RECESSED4-32W T8
RECESSED3-32W T8
RECESSED
SURFACE2-32W T8
2-32W T8
SURFACE4-32W T8
SURFACE
SURFACE
PENDANT
RECESSED
1-32W CFL
1-32W CFL WALL
WALL
1-400W MH
3-55W CFL
2-32W CFL
DECORATIVE SCONCEWALL
1-1000W MH
1-400W MH HID WALL SCONCEWALL
POLE
POLE
1-100W MH
1-400W MH WALL
WALL
WALL
COOPER 1-100W MH
1-100W MH
ENV-100-MH-MT-MB-3SG-BZ-LGR
ENV-100-MH-MT-MB-3S-BZ-LGRCOOPER
ORGATECH
SPECTRUM SPC1210-2-32-E-E2-8610-PM
XZ9400MHR
XZ9355BX
1-55W CFLBETACALCO 40-1105-OP-2
LSI 2LLC-G-332-RPW-SSO10-UE
BEGHELLI BS100-4-HT-D-UNV
LSI CH2HM-3-400-MHR-F-MT-BRZ
LSI CHH-FT-1000-MHR-F-MT-BRZ
LSI CHWM-FT-400-MHR-F-BRZ
S-232-SSO WG240LSI
LSI LA125-2-32-SD-SSO10-UE
LA125-3-32-SD-SSO10-UE
LA125-4-32-SD-SSO10-UE
LSI
LSI
PATHWAY
LSI IMX-4-32-SSO-UE
6HF-1-32T-E4-6HF1
EURS-EB-32-CFL-W-UE-BRZLSI
SPECTRUM SG7MH-ED17-100-E2-AR7150CL
LSI WB-232-SSO10-EM-UE
XX400MH
REFER TO MPE SHEETS FOR ADDITIONAL
SEISMIC DETAILS AND CONDUIT PENETRATION
DETAILS FOR FIRESTOPPING.
GENERAL DETAIL NOTE
ELECTRICAL -
LEGEND &
SCHEDULES
LIGHTING CONTACTOR SCHEDULE
CONTACTOR VOLTAGE POLES TYPE REMARKS
NEMA 1
NEMA 1 6
LC1
LC2
SYMBOLS GENERAL NOTES:
LC2
OTHERWISE NOTED.
LC2
UNLESS OTHERWISE NOTED. WHERE SWITCHES OR RECEPTACLES ARE
A. ALL MOUNTING HEIGHTS GIVEN IN THE LEGEND, SCHEDULES, PLANS,
AND DRAWING NOTES ARE TO THE CENTERLINE OF THE DEVICE, UNLESS
B. INSTALL ALL SWITCHES AT A CENTERLINE HEIGHT OF 46" A.F.F.
MOUNTED ABOVE CASEWORK OR MILLWORK, LOCATE AT A HEIGHT OF 3’-8"
LC2
ADJUST THE MOUNTING HEIGHTS OF THE WIRING DEVICES TO MAKE THE
COVERPLATES CLEAR THE COUNTERTOP OR BACKSPLASH BY 1/2".
LC2
LC2
LC2
NOT NECESSARILY USED IN THIS SET OF CONTRACT DOCUMENTS.
JUNCTION BOX SYMBOL ON THE DRAWINGS DENOTES THE PANELBOARD
CIRCUIT NUMBER TO WHICH DEVICE, FIXTURE, EQUIPMENT OR WIRING
IN JUNCTION BOX IS CONNECTED.
C. WHERE COVERPLATES CONFLICT WITH CASEWORK OR MILLWORK, SLIGHTLY
D. ADDITIONAL SYMBOLS MAY BE SHOWN OR DENOTED ON OTHER SHEETS.
E. ALL SYMBOLS, NOTES, AND ABBREVIATIONS SHOWN ON THE LEGEND ARE
LC2
F. NUMERICAL SUBSCRIPT ADJACENT TO DEVICE FIXTURE, EQUIPMENT OR
MAX. ABOVE FINISH FLOOR OR 3" ABOVE BACKSPLASH TO CENTERLINE.
277V
277V
PHOTOCELL ON/ EMS OFF (SITE LIGHTING)
PHOTOCELL ON/ EMS OFF (FENCED IN AREA)
H 1-100W MHCOOPER 740-MH100PAR38-UNV-MB-BK GROUND FLAG POLE LIGHT
DUAL-HEAD 400W MH ON 30’ POLE2-400W MH POLELSI CH2HM-3-400-MHR-F-MT-BRZ
A1
A2
1-400W MH SINGLE-HEAD 400W MH ON 30’ POLE
PROVIDE FLANGE-MOUNTED FIXTURES (IN LIEU OF GRID-MOUNTED) FOR RECESSED FIXTURES IN DRYWALL CEILING AREAS
CHAIN HANG FIXTURE AS NECESSARY TO BE LOCATED BELOW DUCTWORK AND PIPING.
1.
2.
NOTE 1
ADD’L
NOTES
NOTE 2
NOTE 1
NOTE 1
NOTE 1
NOTE 2
ADDITIONAL FIXTURE NOTES:
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
E 6.01
PANEL: MDP OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): 1200A MCB CONTINUOUS(A): 1200
LOCATION: DEVICE FAMILY: Bolt On MOUNTING: Surfac e WIRING: 3-Phase 4-Wire AIC RATING(A): 65000
FED FROM: VOLTAGE: 480/ 277 FAULT CURRENT(A) 43976
* - 1200A MAIN CIRCUIT BREAKER SHALL BE 100%-RATED
CUBICLE CONNECTED DEMAND DESIGN DESIGN OC DEVICE
NO DESCRIPTION kVA kVA kVA MAX AMPS TYPE SIZE P NOTES
1 PNL H1 159.54 137.16 146.83 209.71 250 3
2 XF L1 PRI 60.20 49.25 49.37 59.68 125 3
3 PNL H2 163.33 135.28 139.94 177.21 250 3
4 XF L2 PRI 70.15 48.22 48.22 59.18 125 3
5 XF L3 PRI 139.00 124.60 125.31 152.57 175 3
6 ATS EQ NORMAL 266.78 221.32 226.51 283.48 400 3
7 OAU-1B 62.66 50.13 50.13 60.29 90 3
8 LWP-1 28.26 22.61 22.61 27.19 70 3 NOTE 1
9 LWP-2 28.26 22.61 22.61 27.19 70 3 NOTE 1
10 CCC-1 54.01 43.21 43.21 51.98 100 3 NOTE 2
11 ELEVATOR 28.25 22.60 22.60 27.19 70 3 SHUNT TRIP
12 SPACE 0.00 0.00 0.00 0.00 225 3
13 SPACE 0.00 0.00 0.00 0.00 225 3
14 SPACE 0.00 0.00 0.00 0.00 225 3
15 SPACE 0.00 0.00 0.00 0.00 400 3
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA
TOTAL CONNECTED 1060.12 1327.1 * A-N 367769.3 1327.1 CONNECTED 1060.12
TOTAL DEMAND 863.58 1085.3 * B-N 348958.0 1259.2 DEMAND 863.58
TOTAL DESIGN 883.85 1116.4 * C-N 343424.4 1239.2 DESIGN 883.85
1. UNDER OPTION #1 THIS CIRCUIT BREAKER SHALL BE A 110A/3-POLE
2. CIRCUIT TO BE PROVIDED UNDER BASE BID AND SHALL BE REMOVED IF OPTION #1 IS ACCEPTED.
PANEL: L1 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): 225A MCB CONTINUOUS(A): 225
LOCATION: DEVICE FAMILY: Bolt On MOUNTING: Surfac e WIRING: 3-Phase 4-Wire AIC RATING(A): 10000
FED FROM: VOLTAGE: 208/ 120 FAULT CURRENT(A) 5988
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC
AMPS P CODE A B C CODE AMPS P
20 1 WKSTN. REC. REC 720 1 1254 2 540 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 3 2254 4 1176 MOTOR ELEV SUMP 20 1
20 1 RECEPTACLES REC 1080 5 1584 6 510 REC ELEV REC 20 1
20 1 RECEPTACLES REC 1080 7 1562 8 500 LTS ELEV CAB LTG 20 1
20 1 RECEPTACLES REC 720 9 720 10 0 SPARE SPARE 20 1
15 1 RP-2 MOTOR 204 11 204 12 0 SPARE SPARE 20 1
20 1 RECEPTACLES REC 720 13 1718 14 1000 EQUIPME VENDING 20 1
20 1 RECEPTACLES REC 720 15 1718 16 1000 EQUIPME VENDING 20 1
20 1 RECEPTACLES REC 720 17 1718 18 1000 EQUIPME VENDING 20 1
20 1 RECEPTACLES REC 1080 19 2078 20 1000 EQUIPME VENDING 20 1
20 1 RECEPTACLES REC 900 21 1898 22 1000 EQUIPME VENDING 20 1
20 1 WKSTN. REC. REC 1080 23 2078 24 1000 EQUIPME VENDING 20 1
20 1 WKSTN. REC. REC 1080 25 2078 26 1000 EQUIPME VENDING 20 1
20 1 WATER COOLER EQUIPME 1000 27 2000 28 1000 EQUIPME VENDING 20 1
20 1 REFRIGERATOR EQUIPME 1000 29 2000 30 1000 EQUIPME VENDING 20 1
20 1 COFFEE MKR EQUIPME 1000 31 1449 32 500 ELEC HE EH-2 20 1
20 1 MICROWAVE EQUIPME 1000 33 1449 34 500 ELEC HE EH-2 20 1
20 1 RECEPTACLES REC 720 35 919 36 200 HVAC UH-1 15 1
20 1 PROJECTOR EQUIPME 500 37 1196 38 696 HVAC VF-5 15 1
20 1 SUMP PNL EQUIPME 500 39 500 40 0 SPARE SPARE 20 1
20 1 WATER COOLER EQUIPME 1000 41 1000 42 0 SPARE SPARE 20 1
20 1 RECEPTACLES REC 1080 43 1080 44 0 SPARE SPARE 20 1
20 1 RECEPTACLES REC 1080 45 1080 46 0 SPARE SPARE 20 1
20 1 RECEPTACLES REC 1080 47 1080 48 0 SPARE SPARE 20 1
20 1 RECEPTACLES REC 1080 49 1080 50 0 SPARE SPARE 20 1
20 1 RECEPTACLES REC 900 51 900 52 0 SPACE SPACE 0 1
20 1 RECEPTACLES REC 1080 53 1080 54 0 SPACE SPACE 0 1
20 1 RECEPTACLES REC 720 55 720 56 0 SPACE SPACE 0 1
20 1 RECEPTACLES REC 720 57 720 58 0 SPACE SPACE 0 1
20 1 MOTORIZED GATE EQUIPME 500 59 500 60 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 61 0 62 0 SPACE SPACE 0 1
20 1 WKSTN. REC. REC 1080 63 1080 64 0 SPACE SPACE 0 1
20 1 WKSTN. REC. REC 1080 65 1080 66 0 SPACE SPACE 0 1
20 1 WKSTN. REC. REC 720 67 720 68 0 SPACE SPACE 0 1
20 1 SHADES EQUIPME 750 69 750 70 0 SPACE SPACE 0 1
20 1 SHADES EQUIPME 750 71 750 72 0 SPACE SPACE 0 1
20 1 SHADES EQUIPME 750 73 750 74 0 SPACE SPACE 0 1
20 1 SHADES EQUIPME 750 75 750 76 0 SPACE SPACE 0 1
20 1 PROJECTOR EQUIPME 500 77 500 78 0 SPACE SPACE 0 1
20 1 PROJECTOR EQUIPME 500 79 4500 80 12000 EQUIPME FUTURE GUARD 60 3
20 1 TELEVISION REC REC 540 81 4537 82 - "" ""
20 1 HOT BOX ELEC HE 1500 83 5334 84 - "" ""
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA
TOTAL CONNECTED 60.20 169.1 * A-N 20143.7 167.7 CONNECTED 60.20
TOTAL DEMAND 49.25 139.1 * B-N 20312.3 169.1 DEMAND 49.25
TOTAL DESIGN 49.37 139.1 * C-N 19750.8 164.5 DESIGN 49.37
PANEL: L2 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): 225A MCB CONTINUOUS(A): 225
LOCATION: DEVICE FAMILY: Bolt On MOUNTING: Surfac e WIRING: 3-Phase 4-Wire AIC RATING(A): 10000
FED FROM: VOLTAGE: 208/ 120 FAULT CURRENT(A) 5988
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC
AMPS P CODE A B C CODE AMPS P
20 1 RECEPTACLES REC 1080 1 1980 2 900 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 720 3 1800 4 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 5 2160 6 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 7 2160 8 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 9 2160 10 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 11 2160 12 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 720 13 1800 14 1080 REC RECEPTACLES 20 1
20 1 PROJECTOR EQUIPME 500 15 1578 16 1080 REC RECEPTACLES 20 1
20 1 VAULT REC. REC 720 17 1620 18 900 REC RECEPTACLES 20 1
20 1 FACP EQUIPME 1000 19 2077 20 1080 REC RECEPTACLES 20 1
20 1 WKSTN. REC. REC 1080 21 2150 22 1080 REC RECEPTACLES 20 1
20 1 WKSTN. REC. REC 1080 23 2150 24 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 900 25 1980 26 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 27 2160 28 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 900 29 1440 30 540 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 31 2160 32 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 33 2160 34 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 35 1800 36 720 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 37 1980 38 900 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 900 39 1800 40 900 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 900 41 1980 42 1080 REC RECEPTACLES 20 1
20 1 RECEPTACLES REC 1080 43 1606 44 528 HVAC UH-2 15 1
20 1 RECEPTACLES REC 900 45 1426 46 528 HVAC UH-2 15 1
20 1 RECEPTACLES REC 900 47 1594 48 696 MOTOR VF-6 15 1
20 1 RECEPTACLES REC 900 49 1762 50 864 MOTOR VF-7 15 1
20 1 PROJECTOR EQUIPME 500 51 1364 52 864 MOTOR VF-8 15 1
20 1 PROJECTOR EQUIPME 500 53 1204 54 750 ELEC HE EH-2 20 1
20 1 WATER COOLER EQUIPME 1000 55 1400 56 400 EQUIPME BOILER 1&2 NOTE 1 20 1
20 1 WKSTN. REC. REC 720 57 1395 58 750 ELEC HE EH-2 20 1
20 1 COFFEE MKR. EQUIPME 1000 59 1200 60 200 EQUIPME BOILER 2 20 1
20 1 MICROWAVE EQUIPME 1000 61 1333 62 375 ELEC HE EH-4 20 1
20 1 REFRIGERATOR EQUIPME 1000 63 1684 64 750 ELEC HE EH-4 20 1
20 1 WKSTN. REC. REC 720 65 1219 66 500 EQUIPME EMCS CONTROLLER 20 1
20 1 TELEVISION REC REC 540 67 1067 68 528 HVAC UH-3 20 1
20 1 TELEVISION REC REC 540 69 1067 70 528 HVAC UH-2 15 1
20 1 WH-1,2,3,4 EQUIPME 500 71 2420 72 1920 MOTOR HHP-1 30 1
20 1 SPARE SPARE 0 73 1920 74 1920 MOTOR HHP-2 30 1
20 1 SPARE SPARE 0 75 1176 76 1176 MOTOR HRP-1 30 1
20 1 SPARE SPARE 0 77 1176 78 1176 MOTOR HRP-1 30 1
20 1 SPARE SPARE 0 79 200 80 200 ELEC HE HEAT TAPE GFI 20 1
20 1 SPARE SPARE 0 81 1656 82 1656 HVAC VF-11 253 1
20 1 SPARE SPARE 0 83 204 84 204 MOTOR RP-1 15 1
20 1 SPARE SPARE 0 85 1000 86 1000 EQUIPME WATER COOLER 20 1
20 1 SPARE SPARE 0 87 0 88 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 89 0 90 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 91 0 92 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 93 0 94 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 95 0 96 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 97 0 98 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 99 0 100 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 101 0 102 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 103 0 104 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 105 0 106 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 107 0 108 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 109 0 110 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 111 0 112 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 113 0 114 0 SPACE SPACE 0 1
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA
TOTAL CONNECTED 70.15 203.0 * A-N 24380.6 203.0 CONNECTED 70.15
TOTAL DEMAND 48.22 140.8 * B-N 23515.7 195.8 DEMAND 48.22
TOTAL DESIGN 48.22 140.8 * C-N 22253.1 185.3 DESIGN 48.22
1. CIRCUIT TO BE PROVIDED UNDER BASE BID AND SHALL BE REMOVED IF OPTION #1 IS ACCEPTED.
PANEL: L3 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): 100A MCB CONTINUOUS(A): 400
LOCATION: DEVICE FAMILY: Bolt On MOUNTING: Surfac e WIRING: 3-Phase 4-Wire AIC RATING(A): 10000
FED FROM: VOLTAGE: 208/ 120 FAULT CURRENT(A) 5557
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC
AMPS P CODE A B C CODE AMPS P
20 1 RECEPTACLES REC 900 1 2021 2 1125 LTS LIGHTING 20 1
20 1 RECEPTACLES REC 720 3 1841 4 1125 LTS LIGHTING 20 1
20 1 RECEPTACLES REC 720 5 1367 6 650 LTS LIGHTING 20 1
20 1 RECEPTACLES REC 720 7 1468 8 750 EQUIPME TTB 20 1
20 1 RECEPTACLES REC 720 9 5550 10 14500 EQUIPME CRANE 60 3
20 1 RECEPTACLES REC 720 11 5550 12 - "" ""
20 1 RECEPTACLES REC 900 13 5729 14 - "" ""
15 3 OVERHEAD DOOR MOTOR 1730 15 8510 16 23800 EQUIPME PARTS WASHER 90 3
"" "" - 17 8510 18 - "" ""
"" "" - 19 8510 20 - "" ""
15 3 OVERHEAD DOOR MOTOR 1730 21 1827 22 2500 EQUIPME PLASMA CUTTER 20 2
"" "" - 23 1827 24 - "" ""
"" "" - 25 5410 26 14500 EQUIPME BATTERY CART 60 3
20 1 CORD REEL REC 500 27 5331 28 - "" ""
20 1 CORD REEL REC 500 29 5331 30 - "" ""
100 3 WELDER EQUIPME 17400 31 13733 32 23800 EQUIPME AIR COMPRESSOR 90 3
"" "" - 33 13733 34 - "" ""
"" "" - 35 13733 36 - "" ""
100 3 WELDER EQUIPME 17400 37 5800 38 0 SPARE SPARE 20 1
"" "" - 39 5800 40 0 SPARE SPARE 20 1
"" "" - 41 5800 42 0 SPARE SPARE 20 1
15 2 PTAC-1 HVAC 1643 43 822 44 0 SPARE SPARE 20 1
"" "" - 45 822 46 0 SPARE SPARE 20 1
20 2 EH-3 ELEC HE 3300 47 1650 48 0 SPARE SPARE 20 1
"" "" - 49 1650 50 0 SPARE SPARE 20 1
20 2 EH-3 ELEC HE 3300 51 1650 52 0 SPARE SPARE 20 1
"" "" - 53 1650 54 0 SPACE SPACE 0 1
15 1 VF-9 HVAC 420 55 420 56 0 SPACE SPACE 0 1
15 1 VF-10 HVAC 420 57 420 58 0 SPACE SPACE 0 1
15 1 EF-2 HVAC 864 59 864 60 0 SPACE SPACE 0 1
15 1 EF-3 HVAC 864 61 864 62 0 SPACE SPACE 0 1
20 1 MOD HVAC 400 63 400 64 0 SPACE SPACE 0 1
20 1 GIH-1 HVAC 400 65 400 66 0 SPACE SPACE 0 1
20 1 EXHAUST SYS. EQUIPME 1000 67 1000 68 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 69 0 70 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 71 0 72 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 73 0 74 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 75 0 76 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 77 0 78 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 79 0 80 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 81 0 82 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 83 0 84 0 SPACE SPACE 0 1
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA
TOTAL CONNECTED 139.00 396.9 * A-N 47658.2 396.9 CONNECTED 139.00
TOTAL DEMAND 124.60 355.9 * B-N 45165.3 376.1 DEMAND 124.60
TOTAL DESIGN 125.31 358.2 * C-N 46187.4 384.6 DESIGN 125.31
ELECTRICAL -
PANEL
SCHEDULES
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/1
/2 g d g n \2
\2
E
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
E 6.02
PANEL: H1 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): MLO CONTINUOUS(A): 250
LOCATION: DEVICE FAMILY: Bolt On MOUNTING: Surfac e WIRING: 3-Phase 4-Wire AIC RATING(A): 42000
FED FROM: VOLTAGE: 480/ 277 FAULT CURRENT(A) 39662
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC
AMPS P CODE A B C CODE AMPS P
20 1 LIGHTING LTS 2294 1 5114 2 2820 LTS EXT. LTG. 20 1
20 1 SPARE SPARE 0 3 650 4 650 LTS EXT. LTG. 20 1
20 1 LIGHTING LTS 2822 5 3798 6 997 HVAC HP-5A 15 1
20 1 LIGHTING LTS 3000 7 11082 8 24431 HVAC OAU-1A 40 3
20 1 LIGHTING LTS 3000 9 11082 10 - "" ""
25 2 WH-7 EQUIPME 9000 11 12644 12 - "" ""
"" "" - 13 6661 14 2161 HVAC HP-9A 15 1
20 1 LIGHTING LTS 1810 15 2789 16 997 HVAC HP-8A 15 1
20 1 LIGHTING LTS 2766 17 4125 18 1385 HVAC HP-4A 15 1
20 1 LIGHTING LTS 2305 19 4435 20 2161 HVAC HP-6A 15 1
20 1 LIGHTING LTS 3581 21 4556 22 997 HVAC HP-3A 15 1
20 1 SPARE SPARE 0 23 1358 24 4074 HVAC HP-10A 15 3
15 3 HP-7A HVAC 7566 25 3880 26 - "" ""
"" "" - 27 3880 28 - "" ""
"" "" - 29 4683 30 2161 HVAC HP-11A 15 1
15 3 HP-1A HVAC 5404 31 3630 32 5487 HVAC HP-2B 15 3
"" "" - 33 3630 34 - "" ""
"" "" - 35 3630 36 - "" ""
15 3 HP-2A HVAC 5487 37 4654 38 8476 HVAC HP-12A 15 3
"" "" - 39 4654 40 - "" ""
"" "" - 41 4654 42 - "" ""
20 1 EH-1 ELEC HE 3000 43 5603 44 8476 HVAC HP-13A 15 3
15 1 EF-1 MOTOR 106 45 2931 46 - "" ""
20 1 HP-1B HVAC 997 47 3822 48 - "" ""
0 1 SPACE SPACE 0 49 2521 50 7562 HVAC HP-14A 15 3
0 1 SPACE SPACE 0 51 2521 52 - "" ""
0 1 SPACE SPACE 0 53 2521 54 - "" ""
20 1 EXTERIOR LTG. LTS 3000 55 4331 56 4072 HVAC HP-15A 15 3
20 1 EXTERIOR LTG. LTS 2200 57 3534 58 - "" ""
20 1 EXTERIOR LTG. LTS 2200 59 3534 60 - "" ""
20 1 EXTERIOR LTG. LTS 3500 61 5979 62 7562 HVAC HP-16A 15 3
20 1 EXTERIOR LTG. LTS 3000 63 5482 64 - "" ""
20 1 FLAG POLE LTS LTS 220 65 2735 66 - "" ""
0 1 SPACE SPACE 0 67 4500 68 9000 EQUIPME WH-6 25 2
0 1 SPACE SPACE 0 69 4500 70 - "" ""
0 1 SPACE SPACE 0 71 0 72 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 73 0 74 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 75 0 76 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 77 0 78 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 79 0 80 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 81 0 82 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 83 0 84 0 SPACE SPACE 0 1
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA
TOTAL CONNECTED 159.54 224.1 * A-N 62098.5 224.1 CONNECTED 159.54
TOTAL DEMAND 137.16 194.6 * B-N 49980.0 180.3 DEMAND 137.16
TOTAL DESIGN 146.83 209.7 * C-N 47567.5 171.6 DESIGN 146.83
PANEL: H2 OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): MLO CONTINUOUS(A): 250
LOCATION: DEVICE FAMILY: Bolt On MOUNTING: Surfac e WIRING: 3-Phase 4-Wire AIC RATING(A): 22000
FED FROM: VOLTAGE: 480/ 277 FAULT CURRENT(A) 12067
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC
AMPS P CODE A B C CODE AMPS P
20 1 LIGHTING LTS 2500 1 5356 2 2856 LTS LIGHTING 20 1
20 1 LIGHTING LTS 2090 3 4601 4 2511 LTS LIGHTING 20 1
20 1 LIGHTING LTS 2905 5 4956 6 2051 LTS LIGHTING 20 1
45 3 OAU-1C HVAC 30511 7 11895 8 1767 LTS LIGHTING 20 1
"" "" - 9 12431 10 2314 LTS LIGHTING 20 1
"" "" - 11 12331 12 2161 HVAC HP-16D 20 1
30 3 OAU-1D HVAC 20119 13 8092 14 4157 HVAC HP-17D 15 3
"" "" - 15 8092 16 - "" ""
"" "" - 17 8092 18 - "" ""
15 3 HP-2C HVAC 5487 19 3990 20 2161 HVAC HP-15D 15 1
"" "" - 21 1829 22 0 SPACE SPACE 0 1
"" "" - 23 1829 24 0 SPACE SPACE 0 1
15 3 HP-1C HVAC 5487 25 3990 26 2161 HVAC HP-10D 15 1
"" "" - 27 1829 28 0 SPACE SPACE 0 1
"" "" - 29 1829 30 0 SPACE SPACE 0 1
15 3 HP-3C HVAC 4074 31 3186 32 5485 HVAC HP-12D 15 3
"" "" - 33 3186 34 - "" ""
"" "" - 35 3186 36 - "" ""
0 1 SPACE SPACE 0 37 0 38 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 39 0 40 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 41 0 42 0 SPACE SPACE 0 1
15 1 HP-14D HVAC 2161 43 3519 44 4074 HVAC HP-5D 15 3
20 1 SPARE SPARE 0 45 1358 46 - "" ""
20 1 SPARE SPARE 0 47 1358 48 - "" ""
15 3 HP-18D HVAC 5404 49 4628 50 8480 HVAC HP-1D 15 3
"" "" - 51 4628 52 - "" ""
"" "" - 53 4628 54 - "" ""
15 3 HP-13D HVAC 4074 55 2743 56 4155 HVAC HP-4D 15 3
"" "" - 57 2743 58 - "" ""
"" "" - 59 2743 60 - "" ""
15 3 HP-9D HVAC 7566 61 3880 62 4074 HVAC HP-7D 15 3
"" "" - 63 3880 64 - "" ""
"" "" - 65 3880 66 - "" ""
15 3 HP-6D HVAC 5404 67 2798 68 997 HVAC HP-3D 20 1
"" "" - 69 3186 70 1385 HVAC HP-2D 20 1
"" "" - 71 1801 72 0 SPARE SPARE 20 1
15 3 HP-11D HVAC 4072 73 1357 74 0 SPARE SPARE 20 1
"" "" - 75 1357 76 0 SPARE SPARE 20 1
"" "" - 77 1357 78 0 SPARE SPARE 20 1
15 1 HP-14D HVAC 2161 79 2161 80 0 SPARE SPARE 20 1
25 2 WH-5 EQUIPME 9000 81 4500 82 0 SPARE SPARE 20 1
"" "" - 83 4500 84 0 SPARE SPARE 20 1
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA
TOTAL CONNECTED 163.33 207.4 * A-N 57463.2 207.4 CONNECTED 163.33
TOTAL DEMAND 135.28 170.9 * B-N 53647.1 193.6 DEMAND 135.28
TOTAL DESIGN 139.94 177.2 * C-N 52372.1 189.0 DESIGN 139.94
PANEL: EQH OC DEVICE TYPE: Breaker ENCLOSURE: NEMA 1 MAINS(A): MLO CONTINUOUS(A): 400
LOCATION: DEVICE FAMILY: Bolt On MOUNTING: Surfac e WIRING: 3-Phase 4-Wire AIC RATING(A): 42000
FED FROM: VOLTAGE: 480/ 277 FAULT CURRENT(A) 37452
OC NOTES DESCRIPTION DEMAND VA CKT PHASE LOADS VA CKT VA DEMAND DESCRIPTION NOTES OC
AMPS P CODE A B C CODE AMPS P
40 3 48-RANGE KITCHEN 24000 1 10761 2 2820 LTS EXT. LIGHTING 20 1
"" "" - 3 9777 4 1819 LTS LIGHTING 20 1
"" "" - 5 8517 6 531 LTS LIGHTING 20 1
60 3 49-OVEN KITCHEN 37000 7 15036 8 2766 LTS LIGHTING 20 1
"" "" - 9 15036 10 2766 LTS LIGHTING 20 1
"" "" - 11 15036 12 2766 LTS LIGHTING 20 1
20 3 36-BOOSTER HTR. KITCHEN 9000 13 4778 14 1810 LTS LIGHTING 20 1
"" "" - 15 3623 16 638 LTS LIGHTING 20 1
"" "" - 17 6023 18 3066 LTS LIGHTING 20 1
25 3 37-BOOSTER HTR. KITCHEN 15000 19 7193 20 2236 LTS LIGHTING 20 1
"" "" - 21 6330 22 3991 MOTOR KEF-1 15 3
"" "" - 23 6330 24 - "" ""
25 3 41-BOOSTER HTR. KITCHEN 15000 25 6330 26 - "" ""
"" "" - 27 5000 28 0 SPACE SPACE 0 1
"" "" - 29 5000 30 0 SPACE SPACE 0 1
25 3 45-KETTLE KITCHEN 15000 31 8333 32 10000 EQUIPME TELCOM REC 20 3
"" "" - 33 8333 34 - "" ""
"" "" - 35 8333 36 - "" ""
25 3 46-ELEC PAN KITCHEN 15000 37 39032 38 102097 NONE XF EQL PRI 175 3
"" "" - 39 39032 40 - "" ""
"" "" - 41 39032 42 - "" ""
20 1 SPARE SPARE 0 43 0 44 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 45 0 46 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 47 0 48 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 49 0 50 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 51 0 52 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 53 0 54 0 SPACE SPACE 0 1
20 1 SPARE SPARE 0 55 0 56 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 57 0 58 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 59 0 60 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 61 0 62 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 63 0 64 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 65 0 66 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 67 0 68 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 69 0 70 0 SPACE SPACE 0 1
0 1 SPACE SPACE 0 71 0 72 0 SPACE SPACE 0 1
ALL CONNECTED KVA MAX PH AMPS * PHASE TOTALS VA AMPS BUS TOTALS KVA
TOTAL CONNECTED 266.78 328.8 * A-N 91127.3 328.8 CONNECTED 266.78
TOTAL DEMAND 221.32 274.9 * B-N 89495.7 322.9 DEMAND 221.32
TOTAL DESIGN 226.51 283.5 * C-N 86234.3 311.2 DESIGN 226.51