207238 E103.pdf

PDF 264 KB Posted

Attached to
Amendment 0004 to this Solicitation
Solicitation number
W912L709R0007
Issued by

About this file

Plan E103

View the file

Other files

File Type Posted
207238 E801D.pdf PDF
207238 E202.pdf PDF
207238 E801C.pdf PDF
207238 E802.pdf PDF
207238 E203.pdf PDF
207238 E201D.pdf PDF
Tullahoma Addendum 2 specification updates 082109.pdf PDF
207238 M502.pdf PDF
207238 E201A.pdf PDF
Tullahoma Addendum 2 A and S plans 082109.pdf PDF
207238 E201C.pdf PDF
207238 E602.pdf PDF
207238 E301C.pdf PDF
207238 M405.pdf PDF
207238 E201B.pdf PDF
207238 E601.pdf PDF
2007042 ADD1 E Supplemental Dwgs 081109.pdf PDF
Addendum 1 Summary of Itemized Changes.pdf PDF
2007042 ADD1 CAS Supplemental Dwgs 081109.pdf PDF
2007042-02_CBAS_vs2000.dwg DWG drawing
2007042 ADD 1 SPEC CHANGES 1 OF 2 081109.pdf PDF
2007042 ADD1 M Supplemental Dwgs 081109.pdf PDF
2007042 ADD 1 SPEC CHANGES 2 OF 2 081109.pdf PDF
2007042 ADD1 P Supplemental Dwgs 081109.pdf PDF
Plans P200-P403 Posted 7-22-09.zip ZIP file
Plans E Sheets Posted 7-22-09.zip ZIP file
Plans M Sheets Posted 7-22-09.zip ZIP file
Plans MPE001-MPE007 Posted 7-22-09.zip ZIP file
Plans E001-E203 Posted 7-22-09.zip ZIP file
Plans Cover Vol 1 2 Posted 7-22-09.zip ZIP file
Plans MPE Sheets Posted 7-22-09.zip ZIP file
Plans A-ID sheets Posted 7-22-09.zip ZIP file
Plans M501-M504 Posted 7-22-09.zip ZIP file
Plans E801A-E8000 Posted 7-22-09.zip ZIP file
Plans A701-A804 Posted 7-22-09.zip ZIP file
Plans P100A-P104 Posted 7-22-09.zip ZIP file
Plans P Sheets Posted 7-22-09.zip ZIP file
Plans FP101A-G202 Posted 7-22-09.zip ZIP file
Plans M001-M104 Posted 7-22-09.zip ZIP file
Plans C-L Sheets Posted 7-22-09.zip ZIP file
Plans A203-A402 Posted 7-22-09.zip ZIP file
Plans E301-E700 Posted 7-22-09.zip ZIP file
Plans G Sheets Posted 7-22-09.zip ZIP file
Plans C001-C401 Posted 7-22-09.zip ZIP file
Plans A901-A1102 Posted 7-22-09.zip ZIP file
Plans A303-A604 7-20-09.zip ZIP file
Plans A101-A302 7-20-09.zip ZIP file
Plans E001-E301D.zip ZIP file
Plans FP101A-G Shts.zip ZIP file
Plans C001-Cover Vol1 Vol 2.zip ZIP file
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OFFICE

TOOL

ROOM

SUPPLY

ROOM

MAINT

WORK BAY

T E

N N

E S

S E

E A

R M

Y N

A T

IO

N

A L

G U

A R

D

R E

A D

IN

E

S S

C E

N T

E R fax web pageweb page phone

Suite 300

615.370.8500

615.370.8530

Kansas City, Missouri

Jackson, Tennessee

Nashville, Tennessee

Brentwood, TN 37024

HART FREELAND ROBERTS, INC.

www.hfrdesign.com

7101 Executive Center Drive

L

K

ENGINEERING

PLANNING

D E S I G N

ARCHITECTURE

J

I

H

G

INTERIORS

34567

F

E

D

C

DATE:

B

A

PROJ. NO.:

34567

9101113 12141516

89101113 12141516

2007042-00 c

C O

P Y

R

IG

H T

A L

L R

IG

H

T S

R E

S E

R V

E D

N

O P

O R

T

IO

N (S

O

F T

H

IS

D O

C U

M E

N T

M A

Y B

E R

E P

R O

D U

C E

D W

IT

H

O U

T T

H E

E X

P R

E S

S E

D W

R

IT

T E

N C

O N

S E

N T

O F

H A

R T

F R

E E

L A

N D

R O

B E

R T

S

IN

C

H F R

/2

/2 g d g n \2

\2

E

.d g n

CONSULTING ENGINEERS

2950 KRAFT DRIVE, SUITE 500

NASHVILLE, TENNESSEE 37204

FAX (615)346-3550

PHONE (615) 346-3400

ICT PROJECT No. 207238

T U

L L

A H

O M

A

T U

L L

A H

O M

A

T N

N G

B

5 JUN. 2009

1 Addendum No. 1 8-11-09

2 Addendum No. 2 8-21-09

E 1.03

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’10’

’1’’1’’1’’1’’1’’1’’1’

S

S

3S

3S

S

S

S

S

L3-6

L3-2 L3-4

LIGHTING -

VEHICLE MAINT

BLDG FLOOR

PLAN

A.

GENERAL NOTES:

B.

DEVICES INDICATED ON THIS DRAWING ARE DIAGRAMMATICAL ONLY.

CONTRACTOR SHALL REFER TO ARCHITECTURAL ELEVATIONS FOR

EXACT LOCATIONS OF OUTLETS, SWITCHES, ETC.

C. CIRCUIT ALL EMERGENCY BALLASTS AHEAD OF SWITCHING.

D.

E. EMERGENCY EGRESS LIGHTING FIXTURES, INDICATED WITH ’NL’

DESIGNATION, SHALL BE CIRCUITED UNSWITCHED.

UNLESS OTHERWISE NOTED, 20A/1P BREAKERS SHALL UTILIZE

#12 AWG CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT

IS IN EXCESS OF 90 LINEAR FEET, CONDUCTORS SHALL BE #10

AWG, WHERE BRANCH CIRCUIT IS IN EXCESS OF 175 LINEAR FEET,

CONDUCTORS SHALL BE #8 AWG, AND WHERE BRANCH CIRCUIT

IS IN EXCESS OF 260 LINEAR FEET, CONDUCTORS SHALL BE #6 AWG.

COORDINATE EXACT LOCATIONS OF LIGHTING FIXTURES WITH

STRUCTURAL FRAMEWORK, MECHANICAL DUCTWORK AND EQUIPMENT

PRIOR TO ROUGH-IN.

1/8" = 1’-0"

ELECTRICAL -

VEHICLE MAINT BLDG FLOOR PLAN

File details come from the government source that posted it. Updated .