207238 E201A.pdf

PDF 491 KB Posted

Attached to
Amendment 0004 to this Solicitation
Solicitation number
W912L709R0007
Issued by

About this file

Plan E201A

View the file

Other files

File Type Posted
207238 E301C.pdf PDF
207238 M405.pdf PDF
207238 E201B.pdf PDF
207238 E601.pdf PDF
Tullahoma Addendum 2 A and S large plans 082109.pdf PDF
207238 E400.pdf PDF
207238 E001.pdf PDF
Addendum 2 Summary of Itemized Changes.pdf PDF
207238 E801D.pdf PDF
207238 E202.pdf PDF
207238 E801C.pdf PDF
207238 E802.pdf PDF
207238 E203.pdf PDF
207238 E201D.pdf PDF
Tullahoma Addendum 2 specification updates 082109.pdf PDF
207238 M502.pdf PDF
207238 E103.pdf PDF
2007042 ADD1 P Supplemental Dwgs 081109.pdf PDF
2007042-02_csit_vs2000.dwg DWG drawing
2007042 ADD1 E Supplemental Dwgs 081109.pdf PDF
Addendum 1 Summary of Itemized Changes.pdf PDF
2007042 ADD1 CAS Supplemental Dwgs 081109.pdf PDF
2007042-02_CBAS_vs2000.dwg DWG drawing
Plans P100A-P104 Posted 7-22-09.zip ZIP file
Plans P Sheets Posted 7-22-09.zip ZIP file
Plans FP101A-G202 Posted 7-22-09.zip ZIP file
Plans M001-M104 Posted 7-22-09.zip ZIP file
Plans C-L Sheets Posted 7-22-09.zip ZIP file
Plans A203-A402 Posted 7-22-09.zip ZIP file
Plans E301-E700 Posted 7-22-09.zip ZIP file
Plans G Sheets Posted 7-22-09.zip ZIP file
Plans C001-C401 Posted 7-22-09.zip ZIP file
Plans A901-A1102 Posted 7-22-09.zip ZIP file
Plans A101-A202b Posted 7-22-09.zip ZIP file
Plans M201A-M406 Posted 7-22-09.zip ZIP file
Plans S Sheets Posted 7-22-09.zip ZIP file
Plans A501-A605 Posted 7-22-09.zip ZIP file
List of Drawings -Tullahoma RC Project.pdf PDF
Plans S201A-S501 Posted 7-22-09.zip ZIP file
Plans S100A-S103 Posted 7-22-09.zip ZIP file
Plans ID101a-L102 Posted 7-22-09.zip ZIP file
Specifications document Posted 7-22-09.zip ZIP file
Plans P200-P403 Posted 7-22-09.zip ZIP file
Plans E Sheets Posted 7-22-09.zip ZIP file
Plans M Sheets Posted 7-22-09.zip ZIP file
Plans MPE001-MPE007 Posted 7-22-09.zip ZIP file
Plans E001-E203 Posted 7-22-09.zip ZIP file
Plans Cover Vol 1 2 Posted 7-22-09.zip ZIP file
Plans A101-A302 7-20-09.zip ZIP file
Plans C001-Cover Vol1 Vol 2.zip ZIP file
Show 40 more

50 files listed here. See the rest on GovTribe.

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

UP

UP

U

PU

P

8’4"x5’9"

SHAFT MIN

5’ DEEP

SUMP PIT

UP

UP

U P U

P

UP

D.S.

W/DRAIN

BOOT

D.S.

W/DRAIN

BOOT

8’4"x5’9"

SHAFT MIN

5’ DEEP

SUMP PIT

T E

N N

E S

S E

E A

R M

Y N

A T

IO

N

A L

G U

A R

D

R E

A D

IN

E

S S

C E

N T

E R fax web pageweb page phone

Suite 300

615.370.8500

615.370.8530

Kansas City, Missouri

Jackson, Tennessee

Nashville, Tennessee

Brentwood, TN 37024

HART FREELAND ROBERTS, INC.

www.hfrdesign.com

7101 Executive Center Drive

L

K

ENGINEERING

PLANNING

D E S I G N

ARCHITECTURE

J

I

H

G

INTERIORS

34567

F

E

D

C

DATE:

B

A

PROJ. NO.:

34567

9101113 12141516

89101113 12141516

2007042-00 c

C O

P Y

R

IG

H T

A L

L R

IG

H

T S

R E

S E

R V

E D

N

O P

O R

T

IO

N (S

O

F T

H

IS

D O

C U

M E

N T

M A

Y B

E R

E P

R O

D U

C E

D W

IT

H

O U

T T

H E

E X

P R

E S

S E

D W

R

IT

T E

N C

O N

S E

N T

O F

H A

R T

F R

E E

L A

N D

R O

B E

R T

S

IN

C

H F R

/2

/2 g d g n \2

\2

E

A

.d g n

CONSULTING ENGINEERS

2950 KRAFT DRIVE, SUITE 500

NASHVILLE, TENNESSEE 37204

FAX (615)346-3550

PHONE (615) 346-3400

ICT PROJECT No. 207238

T U

L L

A H

O M

A

T U

L L

A H

O M

A

T N

N G

B

5 JUN. 2009

1 Addendum No. 1 8-11-09

2 Addendum No. 2 8-21-09

FRONT

ENTRY

FOYER

FAMILY

SPT

D102

30TH TC

ENTRANCE

D101

30TH HHC

ADMIN

D104

LOBBY

(OPEN TO ABOVE)

1175TH

ENTRANCE

A101

MAINT #8

FAC

MAINT #7

D105

STAIRS

LOBBY

STAIRS

TELCOM

CORRIDOR

1175TH

ADMIN

A104

RECRUIT

A102

FAC

MAINT#6

A103

FAC

MAINT#5

A105

TELCOM

A106

TOIL.

A107

C O

R R

ID

O

R

A

1175TH ADMIN

M DAY AREA

A108

BREAK #1

A110

OFFICE

A111

CO 1SG

A112

CO CDR

A113

CLASSROOM #1

A114

RNCO

A116

ELEV EQ

A115

FAC

MAINT #1

B112

1175TH ADMIN

M DAY AREA

A117

B113a

PLANTER

B113b

PLANTER

A

ELEV EQ

A115

KEYPLAN

E 2.01a

POWER - FIRST FLOOR PLAN PART A

L

L

FS

FS

FS

FS

J

L

F

F S

SD

SD

SD

F

L

FS

L

L

L

L L L

L

L

L

FS

FS

FS

FS

FS

SD E

SD SD

1/8" = 1’-0"

L1-3

L1-5

L1-7

L1-19

L1-9

L1-13

L1-17

L1-29

L1-31 L1-33

L1-27

L1-21

POWER &

SYSTEMS -

FIRST FLOOR

PLAN PART A

EQL-42

EQL-44

GENERAL NOTES:

MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.

B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP

MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT

DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT

THE FARTHEST BRANCH CIRCUIT LOAD.

C.

D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS

PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS

FOR EXACT QUANTITIES AND LOCATIONS.

E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER

SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT

DIAMETER.

UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG

CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF

90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH

CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.

1.

ELECTRICAL NOTES:

JUNCTION BOX AND SWITCH TO SERVE MOTORIZED SCREEN. COORDINATE

EXACT ROUGH-IN REQUIREMENTS WITH EQUIPMENT VENDOR.

FAA

TV

J S

CLG

L1-37

TV

L1-35

J

L1-23,25

L1-1

TVJ

L1-63,65

L1-67

F S

TS

TS

EQL-51

WP

EQL-8

HD

HD

SD

ENLARGED ELEVATOR PLAN

1/4" = 1’-0"

3/4 "C. HOMERUN TO COMMUNICATIONS TERMINAL BOARD WITH

3/4 "C. TO ELEVATOR CAB FOR COMMUNICATIONS.

TO ELEVATOR CAB LIGHTING.

PROVIDE 150 WATT INCANDESCENT SERVICE LIGHTING FIXTURE

WITH WIRE GUARD, HUBBELL #VWX-151-VCG-15 OR EQUIVALENT.

MOUNT SWITCH ADJACENT TO LADDER.

2.

3.

4.

5.

100/3/FAR

30/2/F20

J

S

L1-4

L1-6

L1-8

3 #4, 1 #8G., 1"C.

MDP-11

6. JUNCTION BOX TO SERVE SEMI-RECESSED AUTOMATIC EXTERNAL

DEFIBRILLATOR CABINET.

J

TV

TV

TV

TV

L1-40

EQL-462#10,1#10G, 3/4 "C

NEMA

L5-30

2#10, 1#10G, 3/4 "C

EQL-96,98

EQL-100,102

PROVIDE 12"x 1/4 "x2" DEDICATE COPPER GROUND BAR WITH #2/0

COPPER GROUND WIRE HOMERUN TO BAR ON PANEL ’MDP’.

RECEPTACLE LOCATED IN CEILING.

7.

8.

NEMA

L6-30

NEMA

L6-30

EQL-47,49

2 #10,1 #10G, 3/4 "C.

EQL-74,76

2 #10,1 #10G, 3/4 "C.

NEMA

L6-30

EQL-53

TV

J

J

9. JUNCTION BOX TO SERVE AUTOMATIC DOOR POWER. PROVIDE

ROUGH-IN AS NECESSARY TO DOOR OPERATOR.

L1-80