207238 E202.pdf
PDF 409 KB Posted
- Attached to
- Amendment 0004 to this Solicitation
- Solicitation number
- W912L709R0007
About this file
Plan E202
View the file
Other files
Show 40 more
50 files listed here. See the rest on GovTribe.
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DOWN
DN
8’4"x5’9"
ELEV. SHAFT
DN
DOWN
DN
D N
D O
W N
D O
W N
DN
D N
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
H T
A L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/2
/2 g d g n \2
\2
E
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
2 Addendum No. 2 8-21-09
CANOPY
LRN CTR/
LIBRARY
CR #4
CR #3
BALCONY
BREAK
AREA #4
STAIRS
FAC
MNT #9
TELECOM
WC
ALCOVE
M TOILET
F TOILET
LOBBY
( OPEN TO LOBBY BELOW )
LADDER LADDER
( OPEN TO BELOW
FD
FECFEC
REF
FD
C H
A S
E
A
DN
DN DN DN
E 2.02
POWER - SECOND FLOOR PLAN
F S
F
SF
L
FS FS
F S
L
FF
S
FS
L
FS
L
F S
EQL-50
EQL-52
L1-57
L1-26
L1-28
L1-30
L1-24
L1-22
L1-43
L1-45 L1-47
L1-49
L1-51
L1-53
L1-55
L1-41
POWER &
SYSTEMS -
SECOND
FLOOR PLAN
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
JUNCTION BOX AND SWITCH TO SERVE MOTORIZED SCREEN. COORDINATE
EXACT ROUGH-IN REQUIREMENTS WITH EQUIPMENT VENDOR.
J
CLG
CLG
S
TV
TV
TV
CLG
J S
L1-77 L1-79
L1-81
TS
SD E
1/8" = 1’-0"
HD
SD
NEMA
L6-30
NEMA
L6-30
EQL-88,90
2 #10, 1 #10G, 3/4 "C.
EQL-92,94
2 #10, 1 #10G, 3/4 "C. 2. PROVIDE 12"x 1/4 "x2" DEDICATE COPPER GROUND BAR WITH #2/0
COPPER GROUND WIRE HOMERUN TO BAR ON PANEL ’MDP’.
3. RECEPTACLE LOCATED IN CEILING.
8-20-09
J
4. PROVIDE BRANCH CIRCUIT TO JUNCTION BOX IN CEILING
FOR FUTURE ADDITION OF POWER CIRCUITRY.
J
L1-72
L1-74
L1-76
L1-78
2 2
File details come from the government source that posted it. Updated .