MECH. LOUVER
GLASS
BLOCK
GLASS
BLOCK
GLASS
BLOCK
GLASS
BLOCK
MECH. LOUVER
16’w X 14’h
SECTIONAL
OVERHEAD DOOR
D.S.
W/DRAIN
BOOT
D.S.
W/DRAIN
BOOT
DRINKING
FOUNTAINS
RECYCLE BINS
T E
N N
E S
S E
E A
R M
Y N
A T
IO
N
A L
G U
A R
D
R E
A D
IN
E
S S
C E
N T
E R fax web pageweb page phone
Suite 300
615.370.8500
615.370.8530
Kansas City, Missouri
Jackson, Tennessee
Nashville, Tennessee
Brentwood, TN 37024
HART FREELAND ROBERTS, INC.
www.hfrdesign.com
7101 Executive Center Drive
L
K
ENGINEERING
PLANNING
D E S I G N
ARCHITECTURE
J
I
H
G
INTERIORS
34567
F
E
D
C
DATE:
B
A
PROJ. NO.:
34567
9101113 12141516
89101113 12141516
2007042-00 c
C O
P Y
R
IG
H T
A L
L R
IG
H
T S
R E
S E
R V
E D
N
O P
O R
T
IO
N (S
O
F T
H
IS
D O
C U
M E
N T
M A
Y B
E R
E P
R O
D U
C E
D W
IT
H
O U
T T
H E
E X
P R
E S
S E
D W
R
IT
T E
N C
O N
S E
N T
O F
H A
R T
F R
E E
L A
N D
R O
B E
R T
S
IN
C
H F R
/2
/2 g d g n \2
\2
E
B
.d g n
CONSULTING ENGINEERS
2950 KRAFT DRIVE, SUITE 500
NASHVILLE, TENNESSEE 37204
FAX (615)346-3550
PHONE (615) 346-3400
ICT PROJECT No. 207238
T U
L L
A H
O M
A
T U
L L
A H
O M
A
T N
N G
B
5 JUN. 2009
1 Addendum No. 1 8-11-09
2 Addendum No. 2 8-21-09
TELCOM
ASSEMBLY
HALL
CORRIDOR
CLASSROOM #1
ALCOVE
C118
FAC MAINT #4
B104
BREAK #3
B101
FAC
MT #3
B103
TOIL
B105
OFFICE
B106
KITCHEN
B107
CIRCULATION
B108
SCULLERY
B110 DISH
DROP
B109
FAC
MAINT #1
TABLE
STOR
B111
SPLY OFF
C109
SPLY OFF
C110
SPKLR
B113a
ELEC. RM #2
B102
WATER HEATER
B113b
ELEC.
RM #1
B113c
PLANTER
KEYPLAN
E 2.01b
POWER - FIRST FLOOR PLAN PART B
SD
SD
SD
SD
FS
FS
FS
SD
F S
L
L
L
L
L
F S
SD
’MDP’
T
’L1’
’H1’
ATS
’EQ’
T
’EQL’
L1-14
L1-16
L1-18
L1-20
EQL-22
EQL-18
POWER &
SYSTEMS -
FIRST FLOOR
PLAN PART B
EQL-10
EQL-12
EQL-16
EQL-14
GENERAL NOTES:
MULTIWIRE BRANCH CIRCUITS SHALL BE INSTALLED PER NEC 210-4.A.
B. BRANCH CIRCUIT CONDUCTORS SIZED TO PREVENT VOLTAGE DROP
MAY BE REDUCED IN SIZE AS LOAD SUPPLIED BY REMAINING CIRCUIT
DECREASES. VOLTAGE DROP SHALL NOT EXCEED FIVE PERCENT AT
THE FARTHEST BRANCH CIRCUIT LOAD.
C.
D. PROVIDE TAMPER SWITCHES AND DUCT MOUNTED SMOKE DETECTORS
PER ELECTRICAL SPECIFICATIONS. REFERENCE MECHANICAL DRAWINGS
FOR EXACT QUANTITIES AND LOCATIONS.
E. COMMUNICATIONS/SYSTEMS CONDUITS 2" IN DIAMETER AND LARGER
SHALL HAVE A BEND RADIUS OF NO LESS THAN 10 TIMES THE CONDUIT
DIAMETER.
UNLESS OTHERWISE NOTED, 20A/1P BREAKER SHALL UTILIZE #12 AWG
CONDUCTORS. EXCEPTION: WHERE BRANCH CIRCUIT IS IN EXCESS OF
90 LINEAR FEET, CONDUCTORS SHALL BE #10 AWG AND WHERE BRANCH
CIRCUIT IN EXCESS OF 175 LINEAR FEET, CONDUCTORS SHALL BE #8 AWG.
1.
ELECTRICAL NOTES:
JUNCTION BOX TO SERVE AUTOMATIC SHADES IN CLERESTORY ABOVE.
PROVIDE ROUGH-IN TO CONTROL POINT TO BE LOCATED ADJACENT TO
LIGHTING SWITCHES IN THIS AREA (REFER TO SHEET E1.01b). COORDINATE
EXACT ROUGH-IN REQUIREMENTS WITH EQUIPMENT VENDOR.
J
J1
EQL-56
J
F S
J
EQL-54
TS FL PS
1/8" = 1’-0"
WP
’EQH’
L1-69
L1-71
L1-75
L1-73
J
2. JUNCTION BOX TO SERVE SEMI-RECESSED AUTOMATIC EXTERNAL
DEFIBRILLATOR CABINET.
TV