RFI1dowelsresponseBollard.pdf
PDF 16 MB Posted
- Attached to
- Bollard Farm Federal contract opportunity
- Solicitation number
- W912L618R5003
- Issued by
- Department of the Army National Guard
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Form_1419_Bollard_Farm_Project.pdf | ||
| Form_1419_Bollard_Farm_Project.pdf | ||
| Pre_Bid_Job_Walk_25_July_2018.pdf | ||
| Amendment_2.pdf | ||
| RFI_3_162028_wage_det.pdf | ||
| Wage_Determination.pdf | ||
| RFI1dowelsresponseBollarda.pdf | ||
| 18-R-5003-01.pdf | ||
| Combined_DWG's.pdf | ||
| W912L6-18-R-5003_Solicitation_Bollard_Farm.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REQUEST FOR INFORMATION
(RFI)
PROJECT TITLE: Demo Pavement and Install New Bollards RFI NO: 1
PROJECT NUMBER: YZEU162028
BASE: WRANG
DISTRIBUTION/ROUTING Date Initials Critical: Yes No Contractor to Contracting 8/01/18 Contracting Received Date Req’d:
Contracting to COR COR Received COR to A & E (if necessary) A & E Received A & E to COR COR Received COR to Contractor & Contracting
SUBJECT: Concrete Specifications Drawing/Spec Ref:
Information Requested: Should dowels be required where the old pavement meets the new on the infill? What concrete specifications are required for use on this project.
Attachment(s):
POC: Phone: Organization:
Response: Dowels will be required where new concrete abuts to existing concrete. There are two locations identified as concrete. Dowels are to be #4 steel bars 18" long placed at 18" O.C. There are no written specifications for this project the concrete must be 4000 psi or greater mix design.
Attachment(s): 162028 combined drawings POC: DM Phone: 686-5310 Organization: 137 SOCES BCE
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XYXY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
XY
A13 A12 A11 A10 A9 A8 A7 A6 A5 A4 A3 A2 B1B2B3B4B5B6B7B8B9B10B11B12B13
A12A13 A11 A10 A9 A8 A6A7 A5 A4 A3 A2
B1B2B3B4B5B6B7B8B10 B9B11B12B13
N/A
N/A
TBD
N/A
TBD
N/A
N/A
N/A
N/A
1001 - AFFSA-ATS(A) GYM(B)
1052 - ASOS
1020 - ASOS VEHICLE MAINT.
1054 - CE LAWNMOWER SHED
1041 - CE STORAGE/WAREHOUSE
1007 - CIVIL ENGINEERING
1033 - CLS MAINTENANCE
1046 - COMPOSITE SUPPORT / MEDICAL / DFAC
1008 - ENGINEERING INSTAL. SQD
1036 - EM TRAINING FACILITY
1048 - FIRE CRASH/RESCUE STATION
1050 - INTEL SQUADRON
1047 - LOGISTICS READINESS SQUADRON
1034 - LOX FACILITY
1051 - MAIN GATEHOUSE
1011 - MAIN HANGAR / AES / SQUAD SUPPORT
1045 - MOBILITY STORAGE
1010 - MUNITIONS STORAGE
1013 - NOSE DOCK / CLS MAINT.
1049 - POL OPERATIONS
1016 - PROFFESIONAL DEVELOP. CENTER
1035 - SECURITY FORCES
1037 - SF WAREHOUSE/STORAGE
1040 - SQUADRON OPS / COMM
1043 - VEHICLE MAINT/TRANS
1044 - VEHICLE STORAGE
1053 - WEAPONS STORAGE
1038 - WEST GATEHOUSE
1009 - WING HQ
1022 - WING STORAGE
1055- ASOS COVERED STORAGE
1056 SQUADRON OPS TEMP FACILITIES
1 3 7 T H S O W1 3 7 T H S O W
For Official Use Only
Common Installation Picture
1 inch = 129 feet
1 centimeter = 16 meters
Apron Striping Red Line Parking Lanes Structure Buildings WRANGB area
0 260 520 780 1,040130 Feet
60 0 60 120 18030 Meters
Text
AIRCRAFT SHELTERS
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Inserted Text
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Rectangle
1124726340N Callout Bollard Storage Location 1 (30 ea)
1124726340N Rectangle
1124726340N Callout Bollard Storage Location 4 (6 ea)
1124726340N Rectangle
1124726340N Callout Bollard Storage Location 3 (18 ea)
1124726340N Rectangle
1124726340N Rectangle
1124726340N Typewritten Text New Bollard Locations
1124726340N Typewritten Text Bollard Storage Area
1124726340N Callout Concrete Location
1124726340N Callout Concrete Location
1124726340N Rectangle
1124726340N Callout Bollard Storage Location 2 (12 ea)
1124726340N Cross-Out
N.T.S.
A
7" P.C. CONC. PAVEMENT
COMPACT TO 95% STD.
PROCTOR DENSITY
1' x 1' GRAVEL BASE
EXISTING. CONC./ASPHALT
PAVEMENT
5" DIA. STEEL PIPE
6" DIA. STEEL PIPE SLEEVE, 3'-1" LONG (EXTENDS 1" ABOVE PAVEMENT)
#4 BARS LONGITUDINAL (2 EA.) 6" CLR.
REMOVABLE PIPE BOLLARD ROADWAY
REFER BOLLARD DETAIL #3
#4 BARS @ 2' C/C 3" CLR.
2.5'
12"
3'
1/2"
6"
12"
6" DIA. STEEL PIPE SLEEVE
1' x 3' CONC. ENCASEMENT
JOINT TO RECEIVE HOT ASPHALT SEALANT (X2)
FLANGE
N.T.S.
B
7" P.C. CONC. PAVEMENT
COMPACT TO 95% STD.
PROCTOR DENSITY
7" P.C. CONC. PAVEMENT
(REFER TYP. SECTION)
5" DIA. STEEL PIPE
6" DIA. STEEL PIPE SLEEVE, 3'-1" LONG (EXTENDS 1" ABOVE PAVEMENT)
#4 BARS LONGITUDINAL (2 EA.) 6" CLR.
BOLLARD STORAGE TYPICAL SECTION
REFER BOLLARD DETAIL "C"
#4 BARS @ 2' C/C 3" CLR.
2.5'
3'
1/2"
6"
EXISTING BASE COURSE TO REMAIN
1' x 1' GRAVEL BASE
12"
12"
FLANGE
NOTES:
1. CONTRACTOR SHALL PAINT NEW BOLLARDS TO MATCH
EXIST. COLOR AND FINISH, OF EXISTING BOLLARDS.
5" DIA. STEEL PIPE
PAVEMENT SLOPE
6" DIA. STEEL PIPE
5" DIA. STEEL PIPE
4"
6" DIA. STEEL PIPE
5" DIA. PLATE (CAP) WELDED
DETAIL "C-1"
DETAIL "C-1"
1' x 1' GRAVEL BASE
NEW PAVEMENT
SURFACE
WELDED BOLLARD HANDLES
(MIN. #3 REBAR) MATCH EXIST. TYPE
& LOCATION FROM EXIST. BOLLARDS
1' x 3' CONC. ENCASEMENT
N.T.S.
C
FLAT FLANGE (TYP.)
MATCH EXIST. BOLLARDS
REMOVABLE PIPE BOLLARD DETAIL
12"
13"
24" TYP.
EXISTING CURB AND GUTTER
A A
6" PIPE SLEEVE (TYP.)
NOTES:
1. CONTRACTOR SHALL INSTALL 6 (ea) EVENLY PLACE BOLLARDS
ACROSS ENTIRE ROADWAY. BOLLARD SPACING NOT TO EXCEED 3.5
FOOT CENTER TO CENTER.
EXISTING ROADWAY CENTERLINE
EXISTING ROADWAY
3.5' TYP.
SAW CUT LINE
N.T.S.
D
ROADWAY CUT PLAN VIEW
| RFI #1 162028 dowels |
| 162028 combined drawings |
| New Bollard Locations |
| A-DWG |
| B-DWG |
| C-DWG |
| D-DWG |
File details come from the government source that posted it.