(ISSUED 31 AUGUST 2015)
DRAWING INDEX
D
C
B
A
1 2 3 4 5
Designed By:
Drawn By:
Checked By:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
Key Plan:
Revision:
Date: By: Description:
N E
W J
E R
S E
Y A
R M
Y N
A T
IO
N
A L G
U A
R D
N A
T
IO
N A
L G
U A
R D
T R
A
IN
IN
G
C E
N T
E R
N
G T
C
S E
A G
IR
T
N
E W
J E
R S
E Y
S U
P E
R S
T O
R M
S A
N D
Y D
IS
A
S T
E R
R E
S P
O N
S E
P R
O J E
C T
S E
N G
IN
E
E R
IN
G
H O
U S
IN
G
M A
IN
T
E N
A N
C E
S H
O P
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
E
H M
S F
M S
FDYD9400
30 SEPTEMBER 2014
C O
N T
R A
C T
N U
M B
E R
W
F
Y Q
-0 -D
-0
T A
S K
O R
D E
R N
U M
B E
R Z
K
100% BID-FINALS SUBMISSION, ISSUED FOR CONSTRUCTION
299 Madison Avenue, Morristown, New Jersey 07962
Alfred Consoli, AIA New Jersey License: AI-14676
C L o c a l_
R e v it F ile s \N
J A
R N
G S
A N
D Y
E
H M
S F
M S
-A R
C H
-V d y s o n b .r v t
/2
/2
:4 :3
P
M
G-001bR. MESSEL
T. MOON
A. TESTA
GENERAL
DRAWING INDEX
STRUCTURAL
S-001 GENERAL NOTES
S-002 SPECIAL INSPECTIONS
S-101 FOUNDATION PLAN
S-121 ROOF AND CRANE RAIL FRAMING PLANS
S-201 LOADBEARING CMU WALL REINFORCING KEY PLAN
S-202 LOADBEARING CMU WALL REINFORCING ELEVATIONS
S-203 LOADBEARING CMU WALL REINFORCING ELEVATIONS
S-204 LOADBEARING CMU WALL REINFORCING ELEVATIONS
S-501 TYPICAL DETAILS
S-502 TYPICAL DETAILS
S-503 TYPICAL DETAILS
S-510 SECTIONS AND DETAILS
S-511 SECTIONS AND DETAILS
S-520 SECTIONS AND DETAILS
PLUMBING
P-001 PLUMBING GENERAL NOTES, LEGENDS, AND
ABBREVIATIONS
P-111 PLUMBING PLAN
P-411 PLUMBING ENLARGED PLANS
P-511 PLUMBING DETAILS
P-512 PLUMBING DETAILS
P-611 PLUMBING SCHEDULES
P-911 PLUMBING SANITARY RISERS
P-912 PLUMBING WATER RISERS
MECHANICAL
M-001 HVAC GENERAL NOTES, LEGENDS, AND
ABBREVIATIONS
M-111 HVAC PLAN
M-411 HVAC ENLARGED MECHANICAL ROOM PLAN
M-511 HVAC DETAILS
M-512 HVAC DETAILS
M-611 HVAC SCHEDULES
M-811 HVAC CONTROL DIAGRAMS
M-812 BAS POINT FUNCTION SCHEDULE
ELECTRICAL
E-001 ELECTRICAL SYMBOLS, ABBREVIATIONS AND
GENERAL NOTES
ES111 SITE PLAN EHMS/FMS
ES112 SITE ELECTRICAL LAYOUT PLAN
EG111 LIGHTNING PROTECTION AND GROUNDING PLAN
EL111 ELECTRICAL LIGHTING FLOOR PLAN
EP111 ELECTRICAL POWER FLOOR PLAN
EP121 ROOF POWER PLAN
E-511 ELECTRICAL DETAILS
E-512 ELECTRICAL DETAILS
E-513 ELECTRICAL DETAILS
E-611 SINGLE-LINE DIAGRAM
E-711 LIGHTING FIXTURE AND FEEDER SCHEDULE
E-712 EHMS PANEL SCHEDULES
E-713 FMS PANEL SCHEDULES
E-714 MECHANICAL EQUIPMENT SCHEDULES
TELECOMMUNICATIONS & SECURITY
T-001 SYMBOLS, ABBREVIATIONS AND GENERAL NOTES
T-111 TELECOM FLOOR PLAN
T-201 TELECOM RACK ELEVATIONS
T-401 TELECOM ROOM ENLARGED PLANS
T-501 TELECOM OUTLET DETAILS
T-502 TELECOM DETAILS
T-503 SECURITY DETAILS
T-601 TELECOM ONE-LINE DIAGRAMS
T-602 SECURITY ONE-LINE DIAGRAMS
FIRE ALARM
FA-001 FIRE ALARM GENERAL NOTES, ABBREV., AND
SYMBOLS
FA-111 FIRE ALARM PLAN
FA-511 FIRE ALARM RISER DIAGRAM AND DETAILS
FIRE SUPPRESSION
FX-001 FIRE SUPPRESSION GENERAL NOTES, ABBREV., AND
SYMBOLS
FX-002 FIRE SUPPRESSION SITE PLAN
FX-111 FIRE SUPPRESSION PLAN
VAPOR INTRUSION MITIGATION
V-101 GAS VAPOR INTRUSION MITIGATION PLAN SYSTEM
LAYOUT
GENERAL
G-000 COVER
G-001b DRAWING INDEX
G-002 ABBREVIATIONS AND SYMBOLS
G-003 NOTES
G-111 ACCESSIBILITY REQUIREMENTS AND DETAILS
G-115 ACCESSIBILITY PLAN
LIFE SAFETY
LS-001 LIFE SAFETY OVERALL SITE PLAN
LS-111 LIFE SAFETY PLAN
CIVIL
C-001 NOTES, ABBREVIATIONS AND LEGENDS
C-100 OVERALL EXISTING CONDITIONS / SITE DEMOLITION
PLAN
C-101 EXISTING CONDITIONS / SITE DEMOLITION PLAN
C-102 EXISTING CONDITIONS / SITE DEMOLITION PLAN
C-103 EXISTING CONDITIONS / SITE DEMOLITION PLAN
CS-100 OVERALL SITE LAYOUT PLAN
CS-101 SITE LAYOUT PLAN
CS-102 SITE LAYOUT PLAN
CS-111 JOINT LAYOUT PLAN
CS-112 JOINT LAYOUT PLAN
CG-101 SITE GRADING AND DRAINAGE PLAN
CG-102 SITE GRADING AND DRAINAGE PLAN
CG-103 SITE GRADING AND DRAINAGE PLAN
CG-111 EROSION AND SEDIMENT CONTROL PLAN - PHASE I
CG-112 EROSION AND SEDIMENT CONTROL PLAN - PHASE I
CG-113 EROSION AND SEDIMENT CONTROL PLAN - PHASE I
CG-121 EROSION AND SEDIMENT CONTROL PLAN - PHASE II
CG-122 EROSION AND SEDIMENT CONTROL PLAN - PHASE II
CG-123 EROSION AND SEDIMENT CONTROL PLAN - PHASE II
CG-501 EROSION & SEDIMENT CONTROL NOTES AND DETAILS
CG-502 EROSION & SEDIMENT CONTROL NOTES AND DETAILS
CU-101 SITE UTILITY PLAN
CU-102 SITE UTILITY PLAN
CU-201 UTILITY PROFILES
CU-202 UTILITY PROFILES
CU-203 UTILITY PROFILES
C-501 SITE DETAILS
C-502 SITE DETAILS
C-503 SITE DETAILS
C-504 SITE DETAILS
C-505 SITE DETAILS
LANDSCAPE
LP-101 LANDSCAPE PLAN
L-501 LANDSCAPE DETAILS
ARCHITECTURAL
A-001 GENERAL NOTES
A-111 FLOOR PLAN
A-112 REFLECTED CEILING PLAN
A-113 ROOF PLAN
A-114 ENCLOSURE FLOOR PLANS, SECTIONS, AND DETAILS
A-211 EXTERIOR ELEVATIONS
A-311 BUILDING SECTIONS
A-411 ENLARGED FLOOR PLANS
A-415 INTERIOR ELEVATIONS
A-511 EXTERIOR WALL SECTIONS
A-512 EXTERIOR WALL SECTIONS
A-525 EXTERIOR WALL DETAILS
A-526 EXTERIOR WALL DETAILS
A-545 EXTERIOR DETAILS
A-546 EXTERIOR DETAILS
A-555 INTERIOR DETAILS
A-556 INTERIOR DETAILS
A-557 INTERIOR DETAILS
A-611 ROOM FINISH SCHEDULE
A-612 MATERIAL LEGEND
A-613 DOOR SCHEDULE
A-614 WINDOW TYPES
A-711 PARTITION TYPES
A-713 PARTITION DETAILS
A-714 PARTITION DETAILS
A-715 DOOR DETAILS
A-716 DOOR AND LOUVER DETAILS
A-811 SIGNAGE PLAN & EXTERIOR ELEVATION
A-812 SIGN TYPES AND DETAILS
INTERIORS
I-111 FURNITURE PLAN (FOR INFORMATION ONLY)
EQUIPMENT
Q-111 EQUIPMENT FLOOR PLAN
Q-511 EQUIPMENT DETAILS
Q-611 EQUIPMENT SCHEDULES
everetdl Text Box
KEYED NOTE
DOOR NUMBER
PARTITION TYPE (FIRST DIGIT INDICATES
HOURLY FIRE RATING)
ELEVATION TARGET
NORTH ARROW
REVISION CLOUD
REVISION DESIGNATION
WINDOW / LOUVER TYPE
COLUMN REFERENCE
BREAK LINE, MATERIAL
TO CONTINUE
N
INDICATES PLAN NORTH
INTERIOR ELEVATION
DESIGNATION
EXTERIOR ELEVATION
DESIGNATION
SECTION / DETAIL
DESIGNATION
DETAIL DESIGNATION
DRAWING /DETAIL LOCATION DESIGNATION
DRAWING/DETAIL TITLE
DRAWING NUMBER DESIGNATION
WHERE FIRST REFERENCED
DRAWING/DETAIL LIMITS
DRAWING/DETAIL LOCATION DESIGNATION
DRAWING NUMBER DESIGNATION
WHERE FIRST REFERENCED
DRAWING / DETAIL LOCATION DESIGNATION
DRAWING NUMBER DESIGNATION WHERE SHOWN
DRAWING/DETAIL LOCATION DESIGNATION
DRAWING NUMBER DESIGNATION WHERE SHOWN
DRAWING NUMBER DESIGNATION WHERE SHOWN
DRAWING/DETAIL LOCATION DESIGNATION
ELEMENT ELEVATED
EL: DIM VALUE INPUT
A-###
DRAWING NAME
1/8" = 1'-0"
DRAWING SCALE
A#
ROOM IDENTIFIER####
TYPICAL
ROOM
ROOM NAME
ROOM NUMBER
GLASS TYPEG1
STEEL
THERMAL INSULATION (BATT)
THERMAL INSULATION (RIGID)
GYPSUM BOARD
CONCRETE
EARTH
GRANULAR FILL
ACOUSTICAL PANEL CEILING
WOOD ROUGH
CMU
WOOD BLOCKING, SHIM
PARTICLEBOARD OR PLYWOOD
GLASS
CARPET
SOLID SURFACE MATERIAL
D
C
B
A
1 2 3 4 5
Designed By:
Drawn By:
Checked By:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
Key Plan:
Revision:
Date: By: Description:
N E
W J
E R
S E
Y A
R M
Y N
A T
IO
N
A L G
U A
R D
N A
T
IO
N A
L G
U A
R D
T R
A
IN
IN
G
C E
N T
E R
N
G T
C
S E
A G
IR
T
N
E W
J E
R S
E Y
S U
P E
R S
T O
R M
S A
N D
Y D
IS
A
S T
E R
R E
S P
O N
S E
P R
O J E
C T
S E
N G
IN
E
E R
IN
G
H O
U S
IN
G
M A
IN
T
E N
A N
C E
S H
O P
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
E
H M
S F
M S
FDYD9400
30 SEPTEMBER 2014
C O
N T
R A
C T
N U
M B
E R
W
F
Y Q
-0 -D
-0
T A
S K
O R
D E
R N
U M
B E
R Z
K
100% BID-FINALS SUBMISSION, ISSUED FOR CONSTRUCTION
299 Madison Avenue, Morristown, New Jersey 07962
Alfred Consoli, AIA New Jersey License: AI-14676
C L o c a l_
R e v it F ile s \N
J A
R N
G S
A N
D Y
E
H M
S F
M S
-A R
C H
-V d y s o n b .r v t
/2
/2
:4 :3
P
M
G-002R. MESSEL
T. MOON
A. TESTA
GENERAL
ABBREVIATIONS
AND SYMBOLS
GENERAL ABBREVIATIONSGENERAL SYMBOLS VICINITY MAP
LOCATION MAP
MATERIAL SYMBOLS
PROJECT SITE
NOT TO SCALE
PROJECT SITE
NOT TO SCALE
N
N
ABA ARCHITECTURAL BARRIERS ACT
ABI ALTERNATE BID ITEM
ACI AMERICAN CONCRETE INSTITUTE
ADA AMERICANS WITH DISABILITIES
ACT
AFF ABOVE FINISHED FLOOR
AHU AIR HANDLING UNIT
AWP ACOUSTIC WALL PANEL
BLDG BUILDING
BOT BOTTOM
CFCI CONTRACTOR FURNISHED,
CONTRACTOR INSTALLED
CJ CONTROL JOINT
CLG CEILING
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONT CONTINUOUS
CPT CARPET
DWG DRAWING
E EAST
EA EACH
EJ EXPANSION JOINT
EL REFERENCE ELEVATION
ELEC ELECTRIC OR ELECTRICAL
EQ EQUAL
ETC ET CETERA
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXPAN EXPANSION
EXT EXTERIOR
FCO FLOOR CLEAN OUT
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FFE FINISHED FLOOR ELEVATION
FIN FINISH
GALV GALVANIZED
GFGI GOVERNMENT FURNISHED,
GOVERNMENT INSTALLED
GFCI GOVERNMENT FURNISHED,
CONTRACTOR INSTALLED
GYP GYPSUM
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HT HEIGHT
HORIZ HORIZONTAL
HVAC HEATING, VENTILATION AND AIR
CONDITIONING
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
IT INFORMATION TECHNOLOGY
JAN JANITOR
JT JOINT
LAM LAMINATE
MAX MAXIMUM
MDF MEDIUM DENSITY FIBERBOARD
MECH MECHANICAL
MET METAL
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
N NORTH
N/A NOT APPLICABLE
NEC NATIONAL ELECTRIC CODE
NEMA NATIONAL ELECTRIC
MANUFACTURERS ASSOCIATION
NGB NATIONAL GUARD BUREAU
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
OA OVERALL
OC ON CENTER
OFD OVERFLOW DRAIN
OH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
PH PHASE
PLAM PLASTIC LAMINATE
PLAS PLASTIC OR PLASTER
PLBG PLUMBING
PLYWD PLYWOOD
PREFAB PREFABRICATED
PRESS PRESSURE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PTD PAINTED
PVC POLYVINYL CHLORIDE
QT QUARRY TILE
R RISER
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
REBAR REINFORCED STEEL BAR
REF REFERENCE
REQ'D REQUIRED
RM ROOM
RO ROUGH OPENING
SCHED SCHEDULE
SHT SHEET
SIM SIMILAR
SMACNA SHEET METAL AND AIR
CONDITIONING CONTRACTORS
NATIONAL ASSOCIATION
SPEC SPECIFICATION(S)
SQ SQUARE
SF SQUARE FOOT
SS STAINLESS STEEL
STOR STORAGE
STRUCT STRUCTURAL
T TREAD
THK THICK OR THICKNESS
T.O. TOP OF
TOC TOP OF CONCRETE
TBD TO BE DETERMINED
TCNA TILE COUNCIL OF NORTH
AMERICA
TOS TOP OF STEEL
TPO THERMOPLASTIC POLYOLEFIN
TYP TYPICAL
UL UNDERWRITERS LABORATORIES
VCT VINYL COMPOSITE TILE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VTR VENT THROUGH ROOF
WD WOOD
C
B
A
1 2 3 4 5
Designed By:
Drawn By:
Checked By:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
Key Plan:
Revision:
Date: By: Description:
N E
W J
E R
S E
Y A
R M
Y N
A T
IO
N
A L G
U A
R D
N A
T
IO
N A
L G
U A
R D
T R
A
IN
IN
G
C E
N T
E R
N
G T
C
S E
A G
IR
T
N
E W
J E
R S
E Y
S U
P E
R S
T O
R M
S A
N D
Y D
IS
A
S T
E R
R E
S P
O N
S E
P R
O J E
C T
S E
N G
IN
E
E R
IN
G
H O
U S
IN
G
M A
IN
T
E N
A N
C E
S H
O P
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
E
H M
S F
M S
FDYD9400
30 SEPTEMBER 2014
C O
N T
R A
C T
N U
M B
E R
W
F
Y Q
-0 -D
-0
T A
S K
O R
D E
R N
U M
B E
R Z
K
100% BID-FINALS SUBMISSION, ISSUED FOR CONSTRUCTION
299 Madison Avenue, Morristown, New Jersey 07962
Alfred Consoli, AIA New Jersey License: AI-14676
C L o c a l_
R e v it F ile s \N
J A
R N
G S
A N
D Y
E
H M
S F
M S
-A R
C H
-V d y s o n b .r v t
/2
/2
:4 :3
P
M
G-003R. MESSEL
T. MOON
A. TESTA
GENERAL
NOTES
GENERAL NOTES
1. PROVIDE AN AIR BARRIER SYSTEM THAT IS CONTIGUOUS AND CONNECTED ACROSS THE
SIX SURFACES OF THE BUILDING ENVELOPE.
2. ALL AIR BARRIER SYSTEMS SHALL BE FLASHED AND SEALED AIR TIGHT AT ALL WINDOWS,
DOORS, AND AT ALL WALL AND ROOF TRANSITIONS AND PENETRATIONS TO MAINTAIN A
CONTINUOUS PLANE OF AIR TIGHTNESS THROUGHOUT THE BUILDING ENVELOPE.
3. LAP ALL AIR BARRIER SYSTEMS 4" MINIMUM AND SEAL AIR TIGHT ONTO THE ADJACENT
SURFACE TO MAINTAIN A CONTINUOUS PLANE OF AIR TIGHTNESS THROUGHOUT THE
BUILDING ENVELOPE.
AIR BARRIERS
1. THE "OWNER" IS THE NEW JERSEY ARMY NATIONAL GUARD. THE "ARCHITECT/ENGINEER"
IS JACOBS.
2. IF, AT ANY TIME, THE CONTRACTOR DISCOVERS A CONDITION WHICH CONFLICTS WITH
THE DRAWINGS AND/OR SPECIFICATION OR IF THE CONTRACTOR DISCOVERS AN
UNCLEAR OR MISLEADING DIRECTIVE GIVEN IN THE DRAWINGS OR SPECIFICATIONS,
THE CONTRACTOR SHALL BRING THE ISSUE IMMEDIATELY TO THE ATTENTION OF THE
CONTRACTING OFFICER.
3. DO NOT SCALE THE DRAWINGS - FOLLOW WRITTEN DIMENSIONS ONLY.
4. ALL DIMENSIONS FOLLOWED BY +/- OR "VERIFY" ARE EXISTING DIMENSIONS AND SHALL
BE VERIFIED IN THE FIELD. +/- AS USED IN NEW CONSTRUCTION SHALL MEAN THAT THE
DIMENSION IS SLIGHTLY ADJUSTABLE TO ACCOMMODATE ACTUAL CONDITIONS.
5. "MINIMUM" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS
SLIGHTLY ADJUSTABLE BUT MAY NOT VARY TO A DIMENSION OR QUALITY LESSER THAN
THAT INDICATED.
6. "MAXIMUM" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION IS
LIGHTLY ADJUSTABLE BUT MAY NOT VARY TO A DIMENSION OR QUALITY GREATER THAN
THAT INDICATED.
7. "TYPICAL" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION OR
DIMENSION IS THE SAME OR REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.
8. "SIMILAR" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE CONDITION OR
DIMENSION IS THE SAME OR REPRESENTATIVE FOR SIMILAR CONDITIONS THROUGHOUT.
9. "CLEAR" AS USED IN THESE DOCUMENTS SHALL MEAN THAT THE DIMENSION IS NOT
ADJUSTABLE WITHOUT THE APPROVAL OF THE COR. CLEAR DIMENSIONS ARE
TYPICALLY TO FINISHED FACE.
10. "ALIGN" AS USED IN THESE DOCUMENTS SHALL MEAN TO ACCURATELY LOCATE THE
FINISHED FACES IN THE SAME PLANE.
11. ALL WORK INDICATED ON THE DRAWINGS IS THE SOLE RESPONSIBILITY OF THE
CONTRACTOR UNLESS OTHERWISE NOTED.
12. KEYED NOTES LISTED ON DRAWINGS REFER ONLY TO THOSE KEYED NOTE SYMBOLS
ASSOCIATED WITH THE PARTICULAR DRAWING WHERE THE KEYED NOTES ARE LISTED
13. ALL EXPOSED STEEL SHALL BE PAINTED UNLESS OTHERWISE NOTED.
14. ALL GYPSUM PRODUCTS SHALL BE GLASS-MAT. NO PAPER-FACED GYPSUM PRODUCTS
SHALL BE USED ON THIS PROJECT.
15. COORDINATE THE WORK OF ALL TRADES AND CHECK ALL DIMENSIONS. ALL
DISCREPANCIES SHALL BE CALLED TO THE ATTENTION OF THE CONTRACTING OFFICER
AND SHALL BE RESOLVED BEFORE PROCEEDING WITH THE WORK.
16. THE STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION FIRE ALARM,
ELECTRICAL TELECOMMUNICATIONS AND SECURITY, INTERIOR, AND SIGNAGE DRAWINGS
ARE SUPPLEMENTARY TO THE ARCHITECTURAL DRAWINGS. IF A DISCREPANCY EXISTS
BETWEEN THE ARCHITECTURAL DRAWINGS AND ENGINEER'S DRAWINGS, SUCH
DISCREPANCY SHALL BE BROUGHT TO THE CONTRACTING OFFICER'S ATTENTION IN
WRITING PRIOR TO INSTALLATION OF SAID WORK. ANY WORK INSTALLED IN CONFLICT
WITH THE ARCHITECTURAL DRAWINGS SHALL BE CORRECTED BY THE CONTRACTOR
AT CONTRACTOR'S EXPENSE.
16. OWNER WILL MAKE USE OF THE AREAS IN AND SURROUNDING THE CONSTRUCTION
AREAS. EVERY EFFORT SHALL BE MADE TO MINIMIZE THE DISTURBANCE TO
EMPLOYEES, PATRONS, AND TENANTS.
17. MANUFACTURED MATERIALS, EQUIPMENT, ETC SHALL BE INSTALLED IN ACCORDANCE
WITH THE MANUFACTURER'S RECOMMENDATIONS, INSTRUCTIONS, AND ABA/ADA
REQUIREMENTS UNLESS OTHERWISE NOTED.
18. IF DRAWINGS IN THIS SET ARE NOT 30"x 42" THEY HAVE BEEN REVISED FROM THEIR
ORIGINAL SIZE. SCALES NOTED ON PLANS AND DETAILS ARE NO LONGER APPLICABLE.
19. WORK SHALL CONFORM TO APPLICABLE CODES, REGULATIONS, AND ORDINANCES.
CONTRACTOR SHALL OBTAIN ALL REQUIRED BUILDING AND OCCUPANCY PERMITS.
20. ITEMS INDICATED ON THE DRAWINGS AS "GFGI" MEANS GOVERNMENT FURNISHED AND
GOVERNMENT INSTALLED. COORDINATE WITH THE GOVERNMENT FOR THE REQUIRED
POWER, PLUMBING, AND OTHER REQUIRED UTILITIES AS APPLICABLE.
21. ITEMS INDICATED ON THE DRAWINGS AS "GFCI" MEANS GOVERNMENT FURNISHED AND
CONTRACTOR INSTALLED. COORDINATE WITH ALL SCOPE OF WORK.
22. FOR ACCESSIBILITY REQUIREMENTS REFER TO G-111.
23. DO NOT PAINT BUILDING GROUNDING CABLES.
24. PROVIDE SURFICIAL TERMITE TREATMENT UNDER ENTIRE FOOT PRINT OF THE
EHMS/FMS BUILDING.
25. ALL PENETRATIONS THROUGH SHEET METAL ROOF SHALL BE COORDINATED WITH THE
SHEET METAL ROOFING MANUFACTURER / INSTALLER TO ENSURE PENETRATIONS LAND
BETWEEN SEAMS/BATTENS.
26. FURNITURE PLANS AS INDICATED ARE FOR REFERENCE PURPOSE ONLY AND ARE GFGI.
27. MOUNT ALL PIPING, EQUIPMENT, DUCTWORK, ETC. AS HIGH AS POSSIBLE IN ALL AREAS
UNLESS OTHERWISE NOTED. ALL HANGER SUPPORTS SHALL BE ATTACHED TO
STRUCTURAL STEEL. NOTHING MAY BE SUPPORTED FROM ROOF DECK.
NOTES:
CLEAR
FLOOR
SPACE
CLEARANCE REQUIREMENTS AND PROTECTIVE PANEL AT LAVATORY
1. BOTTOM OF PANEL SHALL BE AS HIGH AS POSSIBLE AND
STILL CONCEAL AND PROTECT PIPES.
2. PLACE LAVATORY BOWL AS FAR FORWARD AS POSSIBLE
AND CUT OUT PIPE PROTECTION PANEL AROUND BOWL.
M
IN
9" M
IN
M
IN
M A
X
M A
X
KNEE CLEARANCE
8" MIN
TOE CLEARANCE
6" MAX
17" MIN
30" MIN
M
IN
D E
P T
H
M
IN
M A
X
CLEAR
FLOOR
SPACE
URINAL
FIRE
EXTINGUISHER
OUTLET BOXES
(RECEPTACLES/
VOICE/DATA)
SWITCHES, CONTROLS,
THERMOSTATS AND
FIRE ALARM MANUAL
STATIONS
NOTE: NOTE:
STANDARD URINAL REQUIREMENTS
SPOUT HEIGHT AND CLEARANCE
REQUIREMENTS AT DRINKING
FOUNTAIN
SPOUT BUBBLER
URINALS SHALL BE STALL-TYPE OR
WALL - HUNG WITH RIM AT A
MAXIMUM OF 17" AFF
EQUIPMENT PERMITTED IN
SHADED AREA
M
IN
IM
U
M
30" MINIMUM
1' -1
/2
M
IN
1'
-6
A F
F
4' -0
A
F F
4' -0
M
A X
CLEARANCE
8" MIN KNEE
CLEARANCE
6" MAX TOE
9" M
IN
M
IN
M A
X
14" MINIMUM4" MAXIMUM
ANY
AMOUNT
OBJECT
NOTES:
1. OBJECTS PROJECTING FROM WALLS WHOSE LEADING
EDGES ARE BETWEEN 27" AND 80" ABOVE FINISH FLOOR
SHALL NOT PROTRUDE MORE THAN 4" INTO WALKS, WALLS,
CORRIDORS, PASSAGEWAYS, OR AISLES.
2. OBJECTS WHOSE LEADING EDGES ARE AT OR BELOW 27"
ABOVE FINISH FLOOR, MAY PROTRUDE ANY AMOUNT.
3. WALKS, HALLS, CORRIDORS, PASSAGEWAYS, AISLES, OR
OTHER CIRCULATING SPACES SHALL HAVE A MINIMUM 80"
CLEAR HEADROOM.
2' -3
B
E
LO
W
4" MAX
T H
A N
'-3
H
IG
H E
R
6' -8
M
IN
IM
U M
6" MIN. 6" MIN.
18" MIN,
24" MAX
63" MIN
M
IN
M A
X
ALCOVES SHALL BE A MINIMUM
18" DEEP. IN ADDITION, ALCOVES
SHALL BE A MINIMUM 63" WIDE
AND A MINIMUM OF 32" WIDE FOR
A SINGLE FOUNTAIN.
RECESSED FOUNTAINS:
1.
2.
ACCESSIBLE
COORDINATE ALCOVE SIZE
WITH THE SIZE AND NUMBER
OF DRINKING FOUNTAINS
PROVIDED FOR REQUIRED
CLEARANCES. IF CONFLICT
OCCURS,CONTRACTOR SHALL
SUBMIT RECOMMENDATION
FOR ARCHITECT'S REVIEW
AND APPROVAL
NOTE:
DRINKING FOUNTAINS SHALL BE INSTALLED IN ACCORDANCE WITH
APPLICABLE ADA/ABA GUIDELINES.
IF ALCOVE IS GREATER THAN 24" DEEP,
THEN ALCOVE SHALL BE A MINIMUM OF
36" WIDE.
STANDARD
1. WHERE A TACTILE SIGN IS PROVIDED AT A DOOR, THE SIGN
SHALL BE LOCATED ALONGSIDE THE DOOR AT THE LATCH
SIDE. WHERE A TACTILE SIGN IS PROVIDED AT PAIR DOORS
WITH ONE ACTIVE LEAF, THE SIGN SHALL BE LOCATED ON
THE INACTIVE LEAF. WHERE A TACTILE SIGN IS PROVIDED
AT PAIR DOORS WITH TWO ACTIVE LEAFS, THE SIGN SHALL
BE LOCATED TO THE RIGHT OF THE RIGHT HAND DOOR.
WHERE THERE IS NO WALL SPACE AT THE LATCH SIDE OF A
SINGLE DOOR OR THE RIGHT SIDE OF THE DOUBLE DOORS,
SIGNS SHALL BE LOCATED ON THE NEAREST ADJACENT
PARTITION.
NOTES:
CENTERED ON
TACTILE CHARACTERS
1'-6" MINIMUM
EQ EQ
1' -6
M
IN
IM
U M
.0
REFER TO ADA/ABA
FIGURE 608.2.1
PROVIDE A
VERTICAL GRAB
BAR 18" MINIMUM IN
LENGTH AND 3'-6"
ABOVE HORIZONTAL
GRAB BAR
FOLDING SEAT
HORIZONTAL
GRAB BAR
NOTES:
1. INSIDE FINISHED DIMENSIONS MEASURED AT THE
CENTER POINTS OF OPPOSING SIDES.
2. 3'-0" x 3'-0" DIMENSIONS ARE FROM CERAMIC TILE TO
CERAMIC TILE.
3' -0
M
IN
IM
U M
4'-0" MINIMUM
4" M
A X
IM
U
M
3'-0"
3' -0
1'-6"
DOOR FRAME
SIGNAGE AS SCHEDULED
REFER TO DRAWING
A-811.
SIGNS CONTAINING TACTILE
CHARACTERS SHALL BE
LOCATED SO THAT A CLEAR
FLOOR SPACE OF 18" x 18"
MINIMUM, CENTERED ON THE
TACTILE CHARACTERS,
IS PROVIDED BEYOND THE
ARC OF ANY DOOR SWING
BETWEEN THE CLOSED
POSITION AND 45 DEGREE
OPEN POSITION.
PUSH PLATE OR LEVER
6" AT NON-ACCESSIBLE
LOCATIONS
FLOOR SPACE
1' - 6" CLEAR
T O
B O
T T
O M
O F
H
IG
H E
S T
R A
IS
E
D C
H A
R A
C T
E R
5' -0
M
A X
IM
U
M
CENTER
9"
XXXXXX
XXXX
T O
B O
T T
O M
O F
L O
W E
S T
R A
IS
E
D C
H A
R A
C T
E R
4' -0
M
IN
IM
U M
NOTE:
REFER TO ADA/ABA FIGURE 604.8.1.1 -
STANDARD STALL
5' - 0" MINIMUM (CLEAR)
3' - 0" MIN
1' - 6" CLEAR
6" MAX
4" MAX
3'
M
IN
C
LE
A
R
2' - 0" MIN 2' - 8" MIN
2'
0" M
IN
G R
A B
B A
R
3'
T O
V E
R T
IC
A
L
3'
6" M
IN
IM
U M
1'
M A
X
4'
4" M
IN
IM
U M
6" M
IN
IM
U M
W
A
LL
H U
N G
M
IN
IM
U M
F
LO
O
R M
O U
N T
E D
D
C
B
A
1 2 3 4 5
Designed By:
Drawn By:
Checked By:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
Key Plan:
Revision:
Date: By: Description:
N E
W J
E R
S E
Y A
R M
Y N
A T
IO
N
A L G
U A
R D
N A
T
IO
N A
L G
U A
R D
T R
A
IN
IN
G
C E
N T
E R
N
G T
C
S E
A G
IR
T
N
E W
J E
R S
E Y
S U
P E
R S
T O
R M
S A
N D
Y D
IS
A
S T
E R
R E
S P
O N
S E
P R
O J E
C T
S E
N G
IN
E
E R
IN
G
H O
U S
IN
G
M A
IN
T
E N
A N
C E
S H
O P
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
E
H M
S F
M S
FDYD9400
30 SEPTEMBER 2014
C O
N T
R A
C T
N U
M B
E R
W
F
Y Q
-0 -D
-0
T A
S K
O R
D E
R N
U M
B E
R Z
K
100% BID-FINALS SUBMISSION, ISSUED FOR CONSTRUCTION
299 Madison Avenue, Morristown, New Jersey 07962
Alfred Consoli, AIA New Jersey License: AI-14676
C L o c a l_
R e v it F ile s \N
J A
R N
G S
A N
D Y
E
H M
S F
M S
-A R
C H
-V d y s o n b .r v t
/2
/2
:4 :3
P
M
G-111R. MESSEL
T. MOON
A. TESTA
GENERAL
ACCESSIBILITY
REQUIREMENTS
AND DETAILS
NOT TO SCALEC5
LAVATORIES
NOT TO SCALEB5
MISCELLANEOUS MOUNTING HEIGHTS
NOT TO SCALEA4
PROTRUDING OBJECTS
NOT TO SCALEC4
RECESSED DRINKING FOUNTAIN
NOT TO SCALED5
TACTILE SIGNS AT DOORS
NOT TO SCALEB4
TRANSFER TYPE SHOWER COMPARTMENTS
NOT TO SCALED4
TYPICAL SIGNAGE MOUNTING LOCATION AT DOOR
NOT TO SCALEA5
ACCESSIBLE TOILET STALL
GENERAL ACCESSIBILITY REQUIREMENTS
(REFER TO B5/G-111)
1. WHERE SANITARY FACILITIES ARE LOCATED ON ACCESSIBLE FLOORS OF A BUILDING,
THEY SHALL BE MADE ACCESSIBLE TO PEOPLE WITH DISABILITIES
2. ENTRY TO SANITARY FACILITIES
A. 44" CLEAR AISLES OR CORRIDORS WHERE OCCUPANT LOAD IS 10 OR MORE.
B. DOORWAYS SHALL HAVE 32" CLEAR OPENING.
C. ON APPROACH SIDE, PROVIDE A 60" CLEAR LEVEL SPACE WHEN DOOR SWINGS
TOWARD APPROACH AND 44" SPACE WHEN DOOR SWINGS AWAY FROM
APPROACH.
3. MULTIPLE ACCOMMODATION TOILET FACILITIES (HAVING MORE THAN ONE SANITARY
FIXTURE).
A. PROVIDE A CLEAR SPACE 60" IN DIAMETER AND 27" HIGH OR A CLEAR
SPACE 56" BY 63" AND 27" HIGH.
B. DOORS AT ACCESSIBLE TOILET COMPARTMENT SHALL NOT TO ENCROACH
INTO THE CLEAR SPACE REQUIREMENT.
C. PROVIDE A 28" CLEAR SPACE BETWEEN WATER CLOSET AND FIXTURE AND
32" CLEARANCE BETWEEN WATER CLOSET AND WALL.
D. A 48" LONG CLEAR SPACE IS REQUIRED IN FRONT OF THE WATER CLOSET.
A 60" CLEAR SPACE IS REQUIRED WHEN THE TOILET COMPARTMENT HAS A
SIDE DOOR.
E. DOOR TO WATER CLOSET COMPARTMENT SHALL PROVIDE 32" CLEAR
OPENING FOR END ENTRY AND 34" CLEAR OPENING FOR SIDE ENTRY AND
BE SELF-CLOSING.
F. PROVIDE A 42" CLEAR SPACE IN FRONT OF THE COMPARTMENT DOOR.
4. SINGLE ACCOMMODATION TOILET FACILITY
A. WATER CLOSET SHALL HAVE A 28" CLEARANCE FROM A FIXTURE AND 32"
FROM A WALL. MOUNT DISTANCE 18" FROM NEAR WALL TO CENTER LINE
OF FIXTURE.
B. MINIMUM CLEAR SPACE IN FRONT OF WATER CLOSET SHALL BE 48".
5. GRAB BARS SHALL BE LOCATED ON ONE SIDE AND BACK OF WATER CLOSET
(REFER TO A5/G-111)
A. GRAB BARS SHALL BE 36" ABOVE AND PARALLEL TO THE FLOOR.
B. SIDE GRAB BARS SHALL BE 42" LONG AND PROJECT 24" IN FRONT OF WATER
CLOSET STOOL. GRAB BAR AT BACK SHALL BE 36" LONG.
C. DIAMETER OF GRAB BARS SHALL BE 1 1/4" TO 1 1/2".
D. PROVIDE 1 1/2" CLEARANCE BETWEEN GRAB BARS AND PARTITIONS.
E. GRAB BARS (INCLUDING CONNECTORS, FASTENERS, SUPPORT BACKING, AND ETC.)
SHALL BE DESIGNED TO SUPPORT A 250 POUND LOAD.
F. GRAB BARS SHALL NOT ROTATE WITHIN THEIR FITTINGS.
6. LAVATORIES (REFER TO C5/G-111).
A. PROVIDE A CLEAR FLOOR SPACE OF 30" BY 48" IN FRONT OF LAVATORY
TO PERMIT A FORWARD APPROACH.
B. PROVIDE A CLEAR SPACE BENEATH THE LAVATORY 29" HIGH BY 30" WIDE
BY 8" DEEP AT THE TOP AND 9" HIGH BY 30" WIDE BY 17" DEEP AT THE BOTTOM.
C. HOT AND COLD WATER SUPPLY AND VALVE AND DRAIN PIPES UNDER
LAVATORY SHALL BE INSULATED OR COVERED AND BE FREE OF SHARP
OR ABRASIVE SURFACES.
D. FAUCET CONTROLS AND OPERATING MECHANISMS (OPERABLE WITH ONE HAND)
SHALL BE OF THE TYPE NOT REQUIRING TIGHT GRASPING, PINCHING OR
TWISTING OF THE WRISTS, OR AN OPERATING FORCE EXCEEDING 5 POUNDS.
E. SELF CLOSING VALVES PERMITTED IF FAUCET REMAINS OPEN FOR ATLEAST 10
SECONDS.
F. BOTTOM EDGE OF MIRROR SHALL BE 40 INCHES AFF MAXIMUM.
G. A CLEAR SPACE BENEATH LAVATORIES 29 INCHES HIGH BY 30 INCHES WIDE BY 8
INCHES DEEP AT BOTTOM FROM FRONT OF LAVATORY. HOT \ WATER DRAIN
PIPES SHALL BE INSULATED.
7. URINALS (REFER TO B5/G-111).
A. RIM SHALL BE A MAXIMUM OF 17" ABOVE THE FLOOR.
B. FLUSH CONTROLS SHALL BE OPERABLE BY AN OSCILLATING HANDLE WITH A
MAXIMUM FORCE OF 3 POUNDS AND MOUNTED NO MORE THAN 44" ABOVE THE
FLOOR.
C. PROVIDE A CLEAR SPACE 30" BY 48" IN FRONT OF THE URINAL TO PERMIT A
FORWARD APPROACH.
8. WATER CLOSETS.
A. THE HEIGHT OF THE WATER CLOSET (TOP OF SEAT) SHALL BE BETWEEN
17 AND 19 INCHES.
B. FLUSH CONTROLS SHALL BE OPERABLE BY AN OSCILLATING HANDLE WITH A
MAXIMUM FORCE OF 3 POUNDS, AND SHALL BE ON THE WIDE SIDE OF THE TOILET
STALL.
C. PROVIDE A 28 INCH "CLEAR AREA" BETWEEN TOILET FIXTURE AND SINK FIXTURE
AND 32 INCH "CLEAR AREA" BETWEEN TOILET FIXTURE AND WALL.
9. TOILET ROOM ACCESSORIES
A. BOTTOM EDGE OF MIRRORS SHALL BE NO HIGHER THAN 40" FROM THE FLOOR.
B. TOILET TISSUE DISPENSERS SHALL BE MOUNTED WITHIN 7"-9" FROM THE
FRONT EDGE OF THE TOILET SEAT.
C. OPERATING PARTS OF DISPENSING AND DISPOSAL FIXTURES (TOWEL, SANITARY
NAPKINS, WASTE, COIN SLOTS, ETC.) SHALL BE WITHIN 40" FROM THE FLOOR.
(REFER TO B4/G-111)
1. WHEN BATHING FACILITIES (SHOWERS, LOCKERS) ARE PROVIDED AT LEAST ONE
(NOT LESS THAN 1%) SHALL BE AVAILABLE TO PEOPLE WITH DISABILITIES.
2. SHOWER COMPARTMENTS
A. SHOWER COMPARTMENTS AT LOCKER ROOMS, SHALL BE MINIMUM 36" WIDE,
36" LONG, WITH A 36" ENTRANCE OPENING COMPLIANT WITH ADA/ABA FIGURE
608.2.1. REFERENCE B4/G-111.
B. THRESHOLDS (OR RECESSED DROPS) SHALL BE A MAXIMUM OF 1/2" AND
BEVELED TO A MAXIMUM OF 1:2 (V:H).
C. SHOWER FLOOR SHALL SLOPE AT MAXIMUM 1/2" PER FOOT TO DRAIN
LOCATED 6" FROM THE REAR WALL.
D. SHOWER FLOOR SURFACE SHALL BE OF CARBORUNDUM, GRIT FACE TILE,
OR OF MATERIAL OF EQUIVALENT SLIP RESISTANCE.
(REFER TO B5 AND C4/G-111)
1. DRINKING FOUNTAIN SHALL NOT ENCROACH INTO PEDESTRIAN WAYS.
2. LOCATE DRINKING FOUNTAIN IN ALCOVE NOT LESS THAN 32" WIDE AND 18" DEEP
REFERENCE C4/G-111.
3. PROVIDE A SPACE 27" HIGH AND 18" DEEP UNDER THE DRINKING FOUNTAIN.
4. BUBBLER CONTROL (LEVER OPERATED, ETC.) SHALL BE LOCATED WITHIN 6" OF THE
FRONT OF THE DRINKING FOUNTAIN AND WITHIN 33" ABOVE THE FLOOR.
5. BUBBLER OUTLET ORIFICE SHALL BE LOCATED WITHIN 6" OF THE FRONT OF THE
DRINKING FOUNTAIN AND 36" MAXIMUM ABOVE THE FLOOR WITH THE WATER `
STREAM PARALLEL TO THE FRONT EDGE OF THE DRINKING FOUNTAIN.
1. PROVIDE A WARNING CURB WHERE ABRUPT CHANGES OF 4 INCHES OR MORE
OCCUR BETWEEN THE SIDEWALK AND ADJACENT AREAS SUCH AS PLANTERS, ETC.
2. WARNING CURBS SHALL BE 6 INCHES ABOVE THE WALK SURFACE.
3. WARNING CURBS ARE NOT REQUIRED WHEN HANDRAILS OR GUARDRAILS ARE
PROVIDED WITH A GUIDE RAIL LOCATED 3 INCHES ABOVE THE SURFACE OF THE
WALK.
1. THE INTERNATIONAL SYMBOL OF ACCESSIBILITY SHALL BE THE STANDARD USED TO
IDENTIFY FACILITIES THAT ARE ACCESSIBLE TO AND USABLE BY PHYSICALLY
HANDICAPPED PERSONS.
A. THE SYMBOL SHALL CONSIST OF A WHITE FIGURE ON A BLUE BACKGROUND.
B. CONTRACTED GRADE 2 BRAILLE SHALL BE USED WHERE BRAILLE SYMBOLS
ARE SPECIFICALLY REQUIRED IN OTHER PORTIONS OF THESE STANDARDS.
DOTS SHALL BE 0.1 INCH ON CENTERS IN EACH CELL WITH 0.2 INCH BETWEEN
CELLS. DOTS SHALL BE RAISED A MINIMUM OF 0.025 INCH ABOVE THE
BACKGROUND.
C. LETTERS AND NUMBERS ON SIGNS SHALL HAVE A WIDTH TO HEIGHT RATIO
OF BETWEEN 3:5 AND 1:1 AND A STROKE WIDTH TO HEIGHT RATIO BETWEEN
1:5 AND 1:10.
D. CHARACTERS AND SYMBOLS SHALL CONTRAST WITH THEIR BACKGROUND,
EITHER LIGHT CHARACTERS ON A DARK BACKGROUND OR DARK
CHARACTERS ON A LIGHT BACKGROUND.
E. WHEN RAISED OR RECESSED CHARACTERS OR SYMBOLS ARE USED, THEY
SHALL CONFORM TO THE FOLLOWING:
(1) LETTERS AND NUMBERS ON SIGNS SHALL BE RAISED OR RECESSED
1/32" MINIMUM AND SHALL BE SANS SERIF CHARACTERS.
(2) RAISED CHARACTERS OR SYMBOLS SHALL BE A MINIMUM OF
5/8" HIGH. RECESSED CHARACTERS OR SYMBOLS SHALL HAVE
A 3/4" MINIMUM STROKE WIDTH.
2. SIGNS CONTAINING TACTILE CHARACTERS SHALL BE LOCATED SO THAT A CLEAR
FLOOR SPACE OF 18" MINIMUM BY 18" MINIMUM, CENTERED ON THE TACTILE
CHARACTERS, IS PROVIDED BEYOND THE ARC OF ANY DOOR SWING BETWEEN THE
CLOSED POSITION AND 45 DEGREE OPEN POSITION. REFER TO D5/G-111.
1. AT AREAS OF THE PROJECT THAT ARE ACCESSIBLE TO PEOPLE WITH DISABILITIES,
OBJECTS WITH LEADING EDGES BETWEEN 27" AND 80" ABOVE FINISHED FLOOR
SHALL PROTRUDE NO MORE THAN 4" INTO WALKS, CORRIDORS, ETC. REFER TO
A4/G-111.
1. EVERY ALARM SIGNALING DEVICE SHALL BE OF THE SAME BASIC TYPE BELLS,
HORNS, SPEAKERS, ETC. AS ALL OTHER SIGNALING DEVICES IN THE FACILITY.
1. EMERGENCY WARNING SYSTEMS SHALL ACTIVATE A MEANS OF WARNING THE
HEARING IMPAIRED. FLASHING VISUAL WARNING SHALL HAVE A FREQUENCY OF NOT
LESS THAN 60 FLASHES PER MINUTE AND SHALL BE SYNCHRONIZED.
1. REFER TO A-415 FOR TOILET ROOM ACCESSORIES, FIXTURES AND MOUNTING HEIGHTS.
2. THESE REQUIREMENTS ARE FOR GENERAL REFERENCE AND MAY NOT BE APPLICABLE TO ALL
PORTIONS OF THE PROJECT. THE FACILITY MAY BE EXEMPT AT SPECIFIC LOCATIONS BASED
UPON THE FUNCTION OF THE FACILITY.
3. THESE REQUIREMENTS HAVE BEEN/SHALL BE APPLIED TO ALL AREAS OF THE BUILDING NOTED
ON G-115.
1. A MINIMUM SPACE OF 30" BY 48" IS REQUIRED TO ACCOMMODATE A WHEELCHAIR FOR
FORWARD OR PARALLEL APPROACH. AREAS UNDER PROJECTING OBJECTS MAY BE USED
WHEN ENOUGH KNEE SPACE IS AVAILABLE.
2. FORWARD REACH
A. MAXIMUM 48" HIGH UNOBSTRUCTED REACH PERMITTED FOR FORWARD
APPROACH.
B. MINIMUM 15" LOW REACH PERMITTED FOR FORWARD APPROACH.
C. MAXIMUM 44" HIGH REACH PERMITTED WHEN REACH IS OVER AN
OBSTRUCTION BETWEEN 20" AND 25" WIDE.
3. SIDE REACH
A. MAXIMUM 48" HIGH REACH UNOBSTRUCTED REACH PERMITTED FOR
PARALLEL APPROACH.
B. MINIMUM 15" LOW REACH PERMITTED FOR PARALLEL APPROACH
C. MAXIMUM 46" HIGH REACH PERMITTED WHEN REACH IS OVER AN
OBSTRUCTION BETWEEN 10" AND 24" WIDE.
4. ADDITIONAL MANEUVERING CLEARANCES FOR ALCOVES
A. WHEN FORWARD APPROACH INTO ALCOVE EXCEEDS 24" PROVIDE A 36"
WIDTH.
B. WHEN PARALLEL APPROACH INTO ALCOVE EXCEEDS 15" PROVIDE A 60" LENGTH.
1. THE SURFACE OF THE FLOOR SHALL BE SLIP-RESISTANT.
1. ALL DESIGNATED PRIMARY ENTRANCES TO BUILDINGS AND FACILITIES SHALL BE MADE
ACCESSIBLE TO PEOPLE WITH DISABILITIES AS RECOGNIZED BY ADA/ABA. REFER TO
G-115.
1. HAND ACTIVATED DOOR OPENING HARDWARE SHALL BE MOUNTED 34" TO 44" ABOVE THE FLOOR
AND BE OPERABLE WITH A SINGLE EFFORT BY LEVER TYPE HARDWARE.
2. MAXIMUM EFFORT TO OPERATE DOORS SHALL NOT EXCEED 8.5 POUNDS FOR EXTERIOR DOORS
AND 5 POUNDS FOR INTERIOR DOORS.
3. THE BOTTOM 10" OF ALL DOORS (EXCEPT SLIDING AND AUTOMATIC) SHALL HAVE A SMOOTH
UNINTERRUPTED SURFACE.
4. ALL REQUIRED EXIT DOORWAYS SHALL HAVE A MINIMUM 32" CLEAR OPENING WITH THE DOOR AT
90 DEGREES TO THE CLOSED POSITION.
5. ONE DOOR OF A PAIR OF DOORS SHALL MEET THE MINIMUM WIDTH REQUIREMENTS.
6. MAXIMUM HEIGHT OF THRESHOLD SHALL BE 1/2". MAXIMUM VERTICAL CHANGE AT EDGE IS 1/4"
WITH A MAXIMUM LEVEL OF 45 DEGREE.
7. THE SPACE BETWEEN TWO CONSECUTIVE DOORS (VESTIBULE) SHALL PROVIDE A MINIMUM OF 48
INCHES CLEAR DEPTH BETWEEN THE OPEN AND SECOND CLOSED DOOR. BOTH DOORS AT A
VESTIBULE SHALL SWING IN THE SAME DIRECTION, OR AWAY FROM THE SPACE BETWEEN THEM.
8. EXIT DOORS SHALL SWING IN DIRECTION OF EXIT TRAVEL WHEN SERVING ANY HAZARDOUS AREA
OR WHEN SERVING AN OCCUPANT LOAD OF 50 OR MORE.
9. WIDTH AND HEIGHT OF REQUIRED EXIT DOORWAYS SHALL COMPLY WITH THE INTERNATIONAL
BUILDING CODE.
10. THE WIDTH OF THE DOOR'S "CLEAR AREA" ON THE SWING SIDE OF THE DOOR SHALL EXTEND 24
INCHES PAST STRIKE JAMB FOR EXTERIOR DOORS AND 18 INCHES PAST STRIKE JAMB FOR
INTERIOR DOORS.
11. THERE SHALL BE A CLEAR AREA ON EACH SIDE OF THE DOOR, 60 INCHES DEEP IN THE
DIRECTION OF THE DOOR SWING AND 44 INCHES DEEP IN THE OPPOSITE DIRECTION OF THE
DOOR SWING.
1. WALKS SHALL BE A MINIMUM 48 INCHES WIDE AND CONTINUOUS WITHOUT INTERRUPTIONS.
2. ABRUPT CHANGES SHALL NOT EXCEED 1/4" VERTICAL OR 1/2" BEVELED. CHANGES GREATER
THAN 1/2" SHALL COMPLY WITH REQUIREMENTS FOR CURB RAMPS. NOT STEEPER THAN 1:2
3. WALKS WITH SLOPES GREATER THAN 5% SHALL COMPLY WITH RAMP REQUIREMENTS.
4. WALKS WITH SLOPES 5% AND GREATER SHALL HAVE A 5' LANDINGS EVERY 400 FEET.
5. CROSS SLOPES SHALL NOT EXCEED 1/4" PER FOOT.
6. GRATINGS SHALL HAVE A 1/2" MAXIMUM OPENING IN THE DIRECTION OF TRAVEL.
7. PROVIDE A 5' X 5' LANDING ON THE WALK SIDE OF DOORS THAT SWING TOWARD THE WALK.
8. PROVIDE A LANDING 48 INCHES WIDE BY 44 INCHES DEEP ON THE WALK SIDE OF DOORS
THAT SWING AWAY FROM THE WALK.
9. WALK SHALL EXTEND 24 INCHES TO THE SIDE OF STRIKE EDGE OF DOOR THAT SWINGS TOWARD
THE WALK.
1. OPEN GUARDRAILS SHALL HAVE INTERMEDIATE RAILS OR AN ORNAMENTAL PATTERN SUCH
THAT A SPHERE 4 INCHES IN DIAMETER CANNOT PASS THROUGH.
2. THE OPEN SPACE BETWEEN THE INTERMEDIATE RAILS IN AREAS OF COMMERCIAL AND
INDUSTRIAL-TYPE OCCUPANCIES WHICH ARE NOT ACCESSIBLE TO THE PUBLIC MAY BE SUCH
THAT A SPHERE OF 12 INCHES IN DIAMETER MAY NOT PASS THROUGH.
3. THE TRIANGULAR OPENINGS FORMED BY THE RISER, TREAD, AND BOTTOM ELEMENT OF A
GUARDRAIL AT THE OPEN SIDE OF A STAIRWAY SHALL BE OF SUCH SIZE THAT A SPHERE 6
INCHES IN DIAMETER CANNOT PASS THROUGH.
GENERAL
CLEAR FLOOR OR GROUND SPACE FOR WHEELCHAIRS
FLOORS
ENTRANCES, DOORS AND DOORWAYS
DOORS
WALKS AND SLOPES
GUARDRAIL
SANITARY FACILITIES BATHING FACILITIES
DRINKING FOUNTAINS
HAZARDS
SIGNS OF IDENTIFICATION
PROTRUDING OBJECTS
SIGNALING DEVICE
ALARMS
G-111G-111
G-111
G-111
G-111
G-111
G-111G-111
ACCESSIBILITY PLAN LEGEND
ACCESSIBILITY PLAN GENERAL NOTES
1.
DENOTES AREAS THAT ARE ACCESSIBLE
ACCESSIBLE AREAS SHALL COMPLY WITH :
UFC 1-200-01 (GENERAL BUILDING REQUIREMENTS), 2-11, THE DESIGN IS DIRECTED TO USE
UNIFORM FEDERAL ACCESSIBILITY STANDARDS (UFAS) AND AMERICANS WITH DISABILITIES
ACT ACCESSIBILITY GUIDE (ADAAG) IN LIEU OF CHAPTER 11 OF IBC. THE DISCOUNTED
CHAPTER 11 OF IBC REFERS TO ICC ANSI A117.1-2003. WHILE UFC 1-200-01 DOES NOT
REQUIRE THE FACILITY TO COMPLY WITH ICC ANSI A117.1-2003, THE DESIGN WILL COMPLY
WITH THIS DOCUMENT AS WELL.
ACCORDING TO ABA ACCESSIBILITY STANDARDS FOR DEPARTMENT OF DEFENSE FACILITIES,
203 GENERAL EXCEPTIONS, 203.5 MACHINERY SPACES. SPACES FREQUENTED ONLY BY
SERVICE PERSONNEL FOR MAINTENANCE, REPAIR, OR OCCASIONAL MONITORING OF
EQUIPMENT SHALL NOT BE REQUIRED TO COMPLY WITH THESE REQUIREMENTS OR TO BE ON
AN ACCESSIBLE ROUTE. MACHINERY SPACES INCLUDE, BUT ARE NOT LIMITED TO, ELEVATOR
PITS OR ELEVATOR PENTHOUSES; MECHANICAL, ELECTRICAL OR COMMUNICATIONS
EQUIPMENT ROOMS; PIPING OR EQUIPMENT CATWALKS; WATER OR SEWAGE TREATMENT
PUMP ROOMS OR STATIONS; ELECTRICAL SUBSTATIONS AND TRANSFORMER VAULTS; AND
HIGHWAY AND TUNNEL UTILITY FACILITIES.
1.
ACCESSIBILITY PLAN KEYED NOTES
9876321
F
E
D
C
B
A
4 5
OPERATOR REPAIR
WORKBAY
E-101
OPERATOR REPAIR
WORKBAY
E-102
OPERATOR REPAIR
WORKBAY
E-103
OPERATOR REPAIR
WORKBAY
E-104
GROUND
MAINTENANCE SHOP
E-105
LIBRARY
E-117
LEARNING CENTER
E-116
FACILITY
MAINTENANCE
STORAGE
E-115
MECHANICAL
E-114
CORRIDOR
E-106
GPWB
F-101
BULK POL STORAGE
F-104
BREAK ROOM
E-109
ADMINISTRATION
E-111
DRAFTING SUPPLY
AREA
E-110
VESTIBULE
E-118
CWHF
F-103
FLAMMABLE STORAGE
F-102
ELECTRICAL
E-113
IT TELECOM
E-112
FACILITY
MAINTENANCE
STORAGE
F-108
CORRIDOR
F-107
MENS TOILET /
SHOWER
F-105
WOMENS TOILET /
SHOWER
F-106
FACILITY
MAINTENANCE
STORAGE
F-109
WOMENS TOILET /
SHOWER
E-108
MENS TOILET /
SHOWER
E-107
ENGINEERING HOUSE MAINTENANCE SHOP (EHMS) VEHICLE MAINTENANCE SHOP (FMS)
10 10 10
567 89
2 4
6 7 9
N
D
C
B
A
1 2 3 4 5
Designed By:
Drawn By:
Checked By:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
Key Plan:
Revision:
Date: By: Description:
N E
W J
E R
S E
Y A
R M
Y N
A T
IO
N
A L G
U A
R D
N A
T
IO
N A
L G
U A
R D
T R
A
IN
IN
G
C E
N T
E R
N
G T
C
S E
A G
IR
T
N
E W
J E
R S
E Y
S U
P E
R S
T O
R M
S A
N D
Y D
IS
A
S T
E R
R E
S P
O N
S E
P R
O J E
C T
S E
N G
IN
E
E R
IN
G
H O
U S
IN
G
M A
IN
T
E N
A N
C E
S H
O P
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
E
H M
S F
M S
FDYD9400
30 SEPTEMBER 2014
C O
N T
R A
C T
N U
M B
E R
W
F
Y Q
-0 -D
-0
T A
S K
O R
D E
R N
U M
B E
R Z
K
100% BID-FINALS SUBMISSION, ISSUED FOR CONSTRUCTION
299 Madison Avenue, Morristown, New Jersey 07962
Alfred Consoli, AIA New Jersey License: AI-14676
C L o c a l_
R e v it F ile s \N
J A
R N
G S
A N
D Y
E
H M
S F
M S
-A R
C H
-V d y s o n b .r v t
/2
/2
:4 :3
P
M
G-115R. MESSEL
T. MOON
A. TESTA
GENERAL
ACCESSIBILITY PLAN
1/8" = 1'-0"
24'4' 8' 16'
1 ELECTRICAL / IT / MACHINE ROOMS ARE NOT REQUIRED TO BE ACCESSIBLE PER ABA
2 CUSTODIAL ROOMS ARE NOT REQUIRED TO BE ACCESSIBLE PER ABA.
3 MECHANICAL ROOMS ARE NOT REQUIRED TO BE ACCESSIBLE PER ABA
4 STORAGE ROOMS ARE NOT REQUIRED TO BE ACCESSIBLE PER ABA
5 ACCESSIBLE PUBLIC ENTRANCE
6 ACCESSIBLE EGRESS DOOR
7 REFER TO SITE DRAWINGS FOR PAVEMENT ON EXTERIOR SIDE OF EGRESS DOORS
FOR ACCESSIBLE PATHWAYS
8 PADDLE FOR AUTOMATIC DOOR OPERATOR IN PEDESTAL REFER TO A5/A-546
9 PROVIDE TACTILE EXIT SIGN ON WALL ADJACENT TO LATCH SIDE OF DOOR 54" AFF
FROM THE BASELINE OF THE LOWEST TACTILE CHARACTER STATING "EXIT"
10 WORK BAYS AND MAINTENANCE SHOPS ARE RESTRICTED AREAS
1/8" = 1'-0"A1
EHMS / FMS ACCESSIBILITY PLAN
G-111
0 8' 16'4'
1/8 " = 1'-0"
24'
9876321
F
E
D
C
B
A 4 5
OPERATOR
REPAIR
WORKBAY
E-101
OPERATOR
REPAIR
WORKBAY
E-102
MENS TOILET /
SHOWER
E-107
BREAK ROOM
E-109
ELECTRICAL
E-113
IT TELECOM
E-112
FLAMMABLE
STORAGE
F-102
GPWB
F-101
ADMINISTRATION
E-111
GROUND
MAINTENANCE
SHOP
E-105
OPERATOR
REPAIR
WORKBAY
E-104
OPERATOR
REPAIR
WORKBAY
E-103
FACILITY
MAINTENANCE
STORAGE
E-115
LEARNING
CENTER
E-116
LIBRARY
E-117
VESTIBULE
E-118
FACILITY
MAINTENANCE
STORAGE
F-108
CORRIDOR
F-107
MENS TOILET /
SHOWER
F-105
WOMENS TOILET /
SHOWER
F-106
BULK POL
STORAGE
F-104
CWHF
F-103
WOMENS TOILET /
SHOWER
E-108
CORRIDOR
E-106
FACILITY
MAINTENANCE
STORAGE
F-109
BUILDING CODE SUMMARY
A. OCCUPANT LOAD
X
Y
W
Z
C. EXIT CAPACITY
W = EXIT CAPACITY FACTOR (INCH/PERSON)
X = OCCUPANTS USING EXIT (PERSON)
Y = EXIT CAPACITY (PERSON)
Z = EXIT CLEAR WIDTH (INCH)
D. FIRE RESISTANCE RATING
E. MEANS OF EGRESS
TD = XX TRAVEL DISTANCE (FEET)
ONE HOUR FIRE BARRIER
FE
AED AUTOMATED EXTERNAL DEFIBRILLATOR
YY XX
ZZ
FIRE EXTINGUISHER (CABINET) SIZED
FOR MINIMUM 4-A, 60 B:C
B. OTHER SYMBOLS
AA
ZZ = ROOM AREA (SQ FT)
YY = OCCUPANT LOAD FACTOR
XX = OCCUPANT LOAD
GENERAL NOTES
KEYED NOTES
TWO HOUR FIRE BARRIER
AA = ROOM
MAXIMUM TRAVEL DISTANCE TO EXIT = 250 FT
MAXIMUM DEAD END = 50 FT
MAXIMUM COMMON PATH OF TRAVEL = 100 FT
CODE REFERENCE: IBC, NEW JERSEY BUILDING CODE (2009 EDITION)
INTERNATONAL MECHANICAL CODE (2011 EDITION)
NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS (2007 EDITION)
NFPA 70, NATIONAL ELECTRICAL CODE (2011 EDITION)
NFPA 72, NATIOAL FIRE ALARM CODE (2007 EDITION)
OCCUPANCY: MIXED USE WITH THE FOLLOWING OCCUPANCIES:
BUSINESS (B) - IBC 304.1
FACTORY INDUSTRIAL (F-1) - IBC 306.2
HIGH HAZARD (H-3) - IBC 307.5
STORAGE (S-1) - IBC 311.2
CONSTRUCTION TYPE: II-B
FULLY SPRINKLERED: YES
FIRE ALARM: YES
ALLOWABLE AREA:
THE ALLOWABLE AREA OF THE BUILDING WILL BE BASED ON BOTH SEPARATED AND
NON-SEPARATED MIXED USE PROVISIONS OF THE IBC. THE GROUP H-3 OCCUPANCY
WILL BE SEPARATED FROM THE REMAINDER OF THE BUILDING WITH 2-HOUR FIRE
RATED CONSTRUCTION IN ACCORDANCE WITH IBC 508.2.4. THE REMAINDER OF THE
BUILDING OF THE BUILDING WILL BE CONSIDERED NON-SEPARATED MIXED USE IN
ACCORDANCE WITH IBC 508.3.3. THE ALLOWABLE ARE WILL THEREFORE BE BASED
ON THE SUM OF THE RATIOS OF THE ACTUAL BUILDING AREA DIVIDED BY THE
ALLOWABLE AREA FOR THE H-3 OCCUPANCY AND THE MOST RESTRICTIVE
NON-SEPARATED OCCUPANCY WHICH IS THE F-1 OCCUPANCY.
TOTAL BUILDING AREA: 15,344 FT2
H-3 AREA ACTUAL: 859 FT2
B/F-1/S-1 AREA: 14,485 FT2
ALLOWABLE AREA = {AT+ [AT X IF]+[AT X IS]}
AT = TABULAR AREA (IBC TABLE 503)
IF = AREA INCREASE DUE TO FRONTAGE = 0.75 (IBC 506.2)
IS = AREA INCREASE FOR SPRINKLERS = 3 FOR SINGLE STORY BUILDING (IBC 506.3)
ALLOWABLE AREA BASED ON OCCUPANCY TYPE:
SUM OF RATIOS CALCULATION:
(14,485 / 73,625) + (859 / 24,500) = 0.23
SINCE THE SUM OF THE RATIOS IS LESS THAN 1, TYPE II-B CONSTRUCTION IS
ACCPETABLE
BUSINESS
(B)
FACTORY
(F-1)
STORAGE
(S-1)
HIGH HAZARD
(H-3)
23,000 FT 2
0.75
109,250 FT 2
I
I
A
A t f s a
15,500 FT 2
0.75
73,625 FT 2
17,500 FT 2
0.75
83,125 FT 2
14,000 FT 2
0.75
24,500 FT 2
0.2
0.4
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
0.2
100 31
3,083
100 1
100 1
100 2
100 2
100 2
300 1
300 1
300 2
100 3
100 2
100 2
100 2
100 2
100 2
100 2
100 11
1,095
100 1
15 65
100 4
100 4
100 9
100 11
1,031
100 11
1,031
100 8
100 11
1,031
100 11
1,032
TD = 143
T D
F E
F E
A E
D
FE
FEFE
1 WALL ENCLOSING CARPENTRY SHOP SHALL BE 1-HOUR FIRE
RESISTANCE RATED IN ACCORDANCE WITH NFPA 664 SECTION
6.2.1.2.
H-3 OCCUPANCY
ALLOWABLE HEIGHT: TABLE 503: 2 STORIES - MAXIMUM 55 FEET
INCREASE FOR SPRINKLERS: 3 STORIES - MAXIMUM 75 FEET (IBC 504.2)
ACTUAL HEIGHT: 1 STORY - 35 FEET
QUANTITY
STORED
11HYDRAULIC FLUID
Bulk POL Storage Room
GALLON QUART PLASTIC CONTAINER CUMBUSTIBLE LIQUID - CLASS IIIB
MOTOR OIL
TRANSMISSION FLUID
90W GEAR OIL
ANTIFREEZE
BREAK FLUID (SILICON)
EHMS/FMS - HAZARDOUS MATERIAL STORAGE
ITEM UNIT STORAGE CONTAINER MATERIAL CLASSIFICATION
GALLON
GALLON
GALLON
GALLON
GALLON
QUART PLASTIC CONTAINER
QUART PLASTIC CONTAINER
QUART PLASTIC CONTAINER
GALLON PLASTIC CONTAINER
QUART PLASTIC CONTAINER
CUMBUSTIBLE LIQUID - CLASS IIIB
CUMBUSTIBLE LIQUID - CLASS IIIB
CUMBUSTIBLE LIQUID - CLASS IIIB
N/A
N/A
Hazard Waste Storage Room
WASTE OIL
WASTE ANTIFREEZE
WASTE HYDRAULIC FLUID
WASTE TRANSMISSION FLUID
GALLON
GALLON
GALLON
GALLON
55 GALLON DRUM
55 GALLON DRUM
55 GALLON DRUM
55 GALLON DRUM
CUMBUSTIBLE LIQUID - CLASS IIIB
N/A
CUMBUSTIBLE LIQUID - CLASS IIIB
CUMBUSTIBLE LIQUID - CLASS IIIB
Flammable Storage Room
SPRAY PAINT
PAINT THINNER
OUNCE
GALLON
12 OUNCE CANS
GALLON CANS
FLAMMABLE GAS
CUMBUSTIBLE - CLASS II
NOTE: THE ANTICIPATED HAZARDOUS MATERIAL STORAGE QUANTITIES FOR THIS FACILITY ARE WITHIN THE LIMITS OF IBC TABLE 307.1.1. THE ROOMS ARE PROVIDED WITH FIRE RESISTANCE RATINGS FOR H-3 HAZARD CLASSIFICATION IN THE EVENT THESE LIMITS ARE EXCEEDED.
K
KNOX BOX (REFER TO
ARCH. PLANS FOR
EXACT LOCATION)
1 DCA Comment
N
D
C
B
A
1 2 3 4 5
Designed By:
Drawn By:
Checked By:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
Key Plan:
Revision:
Date: By: Description:
N E
W J
E R
S E
Y A
R M
Y N
A T
IO
N
A L G
U A
R D
N A
T
IO
N A
L G
U A
R D
T R
A
IN
IN
G
C E
N T
E R
N
G T
C
S E
A G
IR
T
N
E W
J E
R S
E Y
S U
P E
R S
T O
R M
S A
N D
Y D
IS
A
S T
E R
R E
S P
O N
S E
P R
O J E
C T
S E
N G
IN
E
E R
IN
G
H O
U S
IN
G
M A
IN
T
E N
A N
C E
S H
O P
V
E H
IC
L E
M A
IN
T
E N
A N
C E
S H
O P
E
H M
S F
M S
FDYD9400
30 SEPTEMBER 2014
C O
N T
R A
C T
N U
M B
E R
W
F
Y Q
-0 -D
-0
T A
S K
O R
D E
R N
U M
B E
R Z
K
100% BID-FINALS SUBMISSION, ISSUED FOR CONSTRUCTION
299 Madison Avenue, Morristown, New Jersey 07962
Alfred Consoli, AIA New Jersey License: AI-14676
C L o c a l_
R e v it F ile s \N
J A
R N
G S
A N
D Y
E
H M
S F
M S
-M E
P F
P T
-V d s h a n a h a n .r v t
/1
/2
:2 :3
P
M
LS-111J.BEALS
B.VAUGHN
J.McLAUGHLIN
LIFE SAFETY
PLAN
1/8" = 1'-0"A1
LIFE SAFETY PLAN
LS-111
B
A
1 2 3 4 5
Designed By:
Drawn By:
Checked By:
Drawing No.:
Date:
Drawing Title:
Jacobs Project No.:
Scales:
Key Plan:
Revision:
Date:
By: Description:
N E
W J
E R
S E
Y A
R M
Y N
A
TI
O N
A L
G U
A R
D N
A
TI
O N
A L
G U
A R
D T
R A
IN
IN
G C
E N
TE
R
(N G
TC
S E
A G
IR
T, N E
W J
E R
S E
Y
SU
PE
R
ST
O R
M S
AN
D
Y D
IS
AS
TE
R
R
ES
PO
N
SE
P
R O
JE
C
TS
EN
G
IN
EE
R
IN
G
H O
U
SI
N G
M
AI
N
TE
N
AN
C E
SH
O
P
VE
H
IC
LE
M
AI
N
TE
N
AN
C E
SH
O
P (E
H M
S / F
M S)
FDYD9400
C O
N
TR
A C
T N
U M
B E
R : W
FY
Q -0
9- D
-0
TA
S K
O R
D E
R N
U M
B E
R : Z
K
30 SEPTEMBER 2014
100% BID-FINALS SUBMISSION, ISSUED FOR CONSTRUCTION
Michael R. Lorenz, PE New Jersey License: 24GE03515600
299 Madison Avenue, Morristown, New Jersey 07962
APPROXIMATEAPPROX
ASPHALTASPH
CONCRETECONC
BLDG
CATCH BASINCB
CI
CO
CURB INLET
CONN CONNECTION
COR
CTR CENTER
CENTERLINE
DEMO DEMOLITION
DET DETAIL
DIA DIAMETER
DIM DIMENSION
E
EA EACH
EL/ELEV ELEVATION
EMH ELECTRIC MANHOLE
FH
FT
EXISTINGEX/EXIST
FIRE HYDRANT
FOOT, FEET
G
IN
GAS
INCH
L
MH
INV INVERT
LENGTH
MAX MAXIMUM
MANHOLE
MIN MINIMUM
MISC MISCELLANEOUS
NTS
N NORTH
NOT TO SCALE
R
S
PVMT PAVEMENT
RADIUS
REF REFERENCE
REQ'D REQUIRED
SOUTH
CONTRACTING OFFICER REPRESENTATIVE
DIP DUCTILE IRON PIPE
LF LINEAR FEET
GV GATE VALVE
SAN SANITARY SEWER
RCP REINFORCED CONCRETE PIPE
PVC POLYVINYL CHLORIDE PIPE
EDGE OF PAVEMENTEP
CL C/L
C&G CURB AND GUTTER
INLET PROTECTIONIP
SCE STABILIZED CONSTRUCTION ENTRANCE
OUTLET PROTECTIONOP
SF SILT FENCE
GMH GAS MANHOLE
TYP TYPICAL
UG UNDERGROUND
W
W/
UTIL UTILITY
WITH
W/O WITHOUT
TC TOP OF CURB
WEST/WATER
WM WATER METER
TMH TELECOMMUNICATIONS MANHOLE
TELCO TELECOMMUNICATIONS
TD TRENCH DRAIN
WV WATER VALVE
BUILDING
VTP VITRIFIED TERRA COTTA PIPE
CU
EAST/ELECTRIC
UNDERGROUND COMMUNICATION LINE
SD STORM SEWER LINE
SS SANITARY SEWER LINE
CMP CORRUGATED METAL PIPE
ACP
W WIDE
NIC NOT IN CONTRACT
AT GRADE INLET PROTECTIONAGIP
CIP CURB INLET PROTECTION
NJDEP NEW JERSEY DEPARTMENT OF ENVIRONMENTAL PROTECTION
NJAC NEW JERSEY ADMINISTRATIVE CODE
1.BOUNDARY INFORMATION SHOWN HEREON IS BASED UPON A FIELD RUN SURVEY BY HERBERT, ROWLAND & GRUBIC, INC.
AND T-3 GLOBAL STRATEGIES IN JULY 2008 AS ILLUSTRATED ON A PLAN TITLED "EXHIBIT SHOWING EXISTING BOUNDARY, TOPOGRAPHY AND RECORD EASEMENTS FOR NEW JERSEY NATIONAL GUARD TRAINING CENTER" DATED OCTOBER 17, 2008, REFERENCING INFORMATION TAKEN FROM A PLAN PREPARED BY THOMAS TYLER MOORE ASSOCIATES, INC. ENTITLED "BOUNDARY SURVEY OF NEW JERSEY NATIONAL GUARD TRAINING CENTER", DATED
AUGUST 21, 1982.
2.EASEMENTS SHOWN AND IDENTIFIED WITH INFORMATION OF RECORD ARE BASED UPON A TITLE SEARCH AND REPORT ISSUED BY RALPH A. ROMANO, NEW JERSEY DIRECT STATE MANAGER, CHICAGO TITLE INSURANCE COMPANY, REFERENCE NUMBER 2008-50296, FOR SEA GIRT BOROUGH, BLOCK 85 LOT 1, TRANSMITTED BY LETTER DATED JUNE 10, 2008.
3.TOPOGRAPHIC INFORMATION SHOWN HEREON WAS PROVIDED BY T3 GLOBAL STRATEGIES, INC., AND IS BASED UPON AERIAL PHOTOGRAPHY OBTAINED IN (OR ABOUT) DECEMBER 2006. THE TOPOGRAPHIC MAP MEETS OR EXCEEDS NATIONAL
MAP ACCURACY STANDARDS AND WAS SUPPLEMENTED BY FIELD SURVEY EFFORTS IN MAY 2011.
4.HORIZONTAL CONTROL PROVIDED BY HERBERT, ROWLAND AND GRUBIC, INC., AND IS BASED UPON NEW JERSEY STATE PLANE COORDINATES AS ESTABLISHED IN THE NORTH AMERICAN DATUM OF 1983 (NAD83(86)).
5.VERTICAL CONTROL BY HERBERT, ROWLAND AND GRUBIC, INC., AND IS BASED UPON THE NORTH AMERICAN VERTICAL
DATUM OF 1988 (NAVD88).
6. A WRITTEN "WAIVER AND DIRECTION NOT TO SET CORNER MARKERS" HAS BEEN OBTAINED FROM THE ULTIMATE USER PURSUANT TO P.L. 2003, c.14 (N.J.S.A. 45:8-36.3) AND N.J.A.C. 13:40-5.1(d), AS RECEIVED AT THE TIME OF THE OCTOBER 2008
BOUNDARY SURVEY.
7.UNDERGROUND UTILITIES SHOWN HEREON WERE MARKED ON THE SITE BY VAN NOTE HARVEY ASSOCIATES, AND LOCATED EITHER BY FIELD SURVEYS, FROM RECORD PLANS, OR FROM EXISTING DRAWINGS DURING THE 2008 SURVEY. UTILITIES HAVE BEEN REVIEWED AND OR SUPPLEMENTED AS PART OF THE 2011 SURVEY SERVICE. THE SURVEYOR MAKES NO GUARANTEES THAT THE UNDERGROUND UTILITIES SHOWN COMPRISE ALL SUCH UTILITIES IN THE AREA, OR THAT THEY ARE IN THE EXACT LOCATION INDICATED, ALTHOUGH THE UTILITIES ARE LOCATED AS ACCURATELY AS POSSIBLE FOR THE
INFORMATION AVAILABLE.
8.THE TIDELANDS SHOWN HEREON WERE IMPORTED FROM GIS MAP DATA (NAD83) OBTAINED FROM THE NEW JERSEY D.E.P.
AS RECEIVED FOR THE OCTOBER 2008 BOUNDARY SURVEY. IT IS THE RESPONSIBILITY OF ALL DESIGNERS, CONTRACTORS, OR END USERS OF THESE PLANS TO VERIFY THE LIMIT OF ANY TIDELANDS PRIOR TO ANY IMPROVEMENTS OR
CONSTRUCTION ACTIVITY IN OR NEAR THE VICINITY OF THE TIDELANDS.
9.WET AREAS SHOWN HEREON ARE BASED UPON A PLAN TITLED "EXHIBIT SHOWING EXISTING BOUNDARY, TOPOGRAPHY AND RECORD EASEMENTS FOR NEW JERSEY NATIONAL GUARD TRAINING CENTER" DATED OCTOBER 17, 2008. NO OTHER WET
AREAS WERE OBSERVED DURING THE EXECUTION OF THE 2011 SURVEY.
10.FLOOD ZONES SHOWN HEREON ARE A GRAPHICAL DEPICTION BASED UPON FEMA FLOOD INSURANCE RATE MAPS 34025C0456F & 34025C0457F. ZONE X DEFINED AS AREAS OUTSIDE 0.2% ANNUAL CHANCE FLOODPLAIN. ZONE X (OTHER FLOOD AREAS) DEFINED AS AREAS OF 0.2% ANNUAL CHANCE FLOOD; AREAS OF 1% ANNUAL CHANCE FLOOD WITH AVERAGE DEPTHS OF LESS THAN 1 FOOT OR WITH DRAINAGE AREAS LESS THAN 1 SQUARE MILE; AND AREAS PROTECTED BY LEVEES FROM 1% ANNUAL CHANCE FLOOD. ZONE AE DEFINED AS SPECIAL FLOOD HAZARD AREAS SUBJECT TO INUNDATION BY THE
1% ANNUAL CHANCE FLOOD, WITH BASE FLOOD ELEVATIONS DETERMINED.
11. NORTH ARROW DEPICTED ON ALL CIVIL PLANS DESIGNATES TRUE NORTH.
CO
FH
S
WV
FM
OR
MB
X
+ 7.6
EXISTING STORMWATER MANHOLE OR INLET
EXISTING STORMWATER PIPE
EXISTING SANITARY SEWER MANHOLE
EXISTING FIRE HYDRANT
EXISTING CLEANOUT
EXISTING WATER LINE
EXISTING WATER VALVE
EXISTING SANITARY SEWER LINE
EXISTING SANITARY SEWER FORCE MAIN
EXISTING GUIDE RAIL
EXISTING CURB
EXISTING EDGE OF PAVEMENT
EXISTING SIGN
EXISTING MAILBOX
EXISTING DITCH OR SWALE
EXISTING STREAM LINE
EXISTING FENCE
2011 SURVEY LIMITS
TREE
EXISTING CONTOUR
EXISTING SPOT ELEVATION
15"
Spruce
EXISTING BUILDING FOOTPRINT
DOOR LOCATION
TRAFFIC/PARKING SIGN
BUILDING FOOTPRINT
CONCRETE CURB
CONCRETE PAVEMENT/SIDEWALK
ASPHALT PAVEMENT
ADA CURB RAMP
PEDESTRIAN CROSSWALK
MAJOR CONTOUR
MINOR CONTOUR
STORM MANHOLE
CATCH BASIN
STORM SEWER
WATER MAIN
GAS MAIN
TELECOMMUNICATION DUCTBANK
SANITARY SEWER
VALVE
FIRE HYDRANT
SANITARY SEWER MANHOLE
C
SD
ASBESTOS CEMENT PIPE
SCREEN WALL/RETAINING WALL
CABLE BEAM BARRIER
U
E U ELECTRICAL LINE
LIGHT POLE
ELECTRICAL MANHOLE
1. LIMITS AND ITEMS SHOWN FOR REMOVAL ARE BASED ON BEST AVAILABLE RECORD MAPPING AND TOPOGRAPHIC SURVEY.
CONTRACTOR SHALL BE RESPONSIBLE FOR REMOVING ANY ITEMS NOT SHOWN WITHIN THE LIMITS OF CONSTRUCTION
NECESSARY TO COMPLETE THE REQUIRED WORK.
2. ANY UTILITIES SHOWN TO BE REMOVED OR ABANDONED IN PLACE ARE TO BE FIELD VERIFIED BY THE CONTRACTOR.
CONTRACTOR SHALL NOTIFY AND SCHEDULE ANY INTENDED UTILITY INTERRUPTIONS WITH THE CONTRACTING OFFICER
REPRESENTATIVE PRIOR TO WORK.
3. COORDINATE ANY UTILITY REMOVAL WITH THE SITE UTILITY PLANS.
4. REMOVE ALL CURB, GUTTER, SIDEWALKS, ASPHALT PAVEMENT, CONCRETE PAVEMENT, BUILDINGS, AND CONCRETE PADS
WITHIN THE LIMITS OF CONSTRUCTION.
5. COORDINATE WITH SITE LAYOUT & GRADING PLANS FOR LIMITS OF REMOVAL
6. ALL UTILITIES MARKED AS TO BE ABANDONED IN PLACE ARE TO REMAIN IN SERVICE UNTIL NEW UTILITIES ARE INSTALLED.
S
D
SURVEY NOTES
GENERAL NOTES
SITE REMOVAL NOTES
CIVIL ABBREVIATIONS EXISTING CONDITIONS LEGEND SITE WORK LEGEND
EXISTING GAS LINE
EXISTING ELECTRIC LINE
EXISTING STORM LINE
EXISTING COMMUNICATION LINE
ABI ADDITIVE BID ITEM
TREE LINE
CLEANOUT
1. PRIOR TO ANY EXCAVATION, CONTRACTOR SHALL CONTACT NEW JERSEY ONE CALL AT 1-800 272-1000 OR (732) 394-3000
TO LOCATE AND MARK ALL EXISTING UTILITIES.
2. CONTRACTOR SHALL CONSTRUCT ALL SANITARY AND STORM SEWERS, BEGINNING AT THE MOST DOWNSTREAM
LOCATION AND CONSTRUCT UPSTREAM.
3. CONTRACTOR SHALL DIG TEST PITS AT ALL UTILITY TIE IN LOCATIONS AND EXISTING UTILITY CROSSINGS TO VERIFY EXISTING INVERT INFORMATION, PIPE SIZES, AND MATERIALS. IF FINDINGS DIFFER FROM WHAT IS SHOWN ON PLANS, CONTRACTOR SHALL NOTIFY THE CONTRACTING OFFICER REPRESENTATIVE IMMEDIATELY, PRIOR TO ANY
CONSTRUCTION.
4. CONTRACTOR SHALL PROVIDE NECESSARY ADAPTERS TO TRANSITION FROM DIFFERENT PIPE SIZES AND MATERIALS SHOWN ON MECHANICAL, PLUMBING AND FIRE PROTECTION PLANS, TO PIPE SIZES AND MATERIALS SHOWN ON THE SITE
UTILITY PLANS.
5. SANITARY SEWER LINES AND WATER MAINS SHALL BE INSTALLED WITH A MINIMUM OF 10' OF HORIZONTAL SEPARATION. THE WATER MAIN SHALL BE INSTALLED A MINIMUM OF 18" ABOVE THE SEWER LINE AND IN A SEPARATE TRENCH. WHERE NEITHER OF THESE SEPARATIONS CAN BE PROVIDED AND/OR THE WATER MAIN NEEDS TO CROSS UNDER THE SEWER LINE, THE SEWER LINE SHALL BE ENCASED IN CONCRETE FOR A MINIMUM DISTANCE OF 10' ON EITHER SIDES OF THE WATER LINE. IN ADDITION, ONE FULL LENGTH OF SEWER PIPE SHALL BE LOCATED SO BOTH JOINTS WILL BE AS FAR FROM THE WATER LINE AS POSSIBLE. ALL SANITARY SEWER MAINS SHALL BE CONSTRUCTED
IN ACCORDANCE WITH NJAC 7:14 A-23 REQUIREMENTS.
6. PROVIDE A MINIMUM OF 36 INCHES COVER OVER ALL SANITARY SEWER MAINS.
7. PROVIDE A MINIMUM OF 42 INCHES COVER OVER ALL WATER MAINS.
8. PROVIDE 45° VERTICAL BENDS TO ROUTE WATERLINES BENEATH OTHER UTILITIES WHERE THERE IS A CONFLICT, AS REQUIRED.
9. CONTRACTOR SHALL REROUTE AND RELOCATE ANY EXISTING UTILITIES IMPACTED BY CONSTRUCTION AS NECESSARY TO MAINTAIN PROPER COVER AND SERVICE OF EXISTING UTILITIES AFTER FINAL GRADING.
10. ALL DIMENSIONS SHOWN ON SITE LAYOUT PLANS ARE PERPENDICULAR AND ARE EITHER TO THE INSIDE FACE OF
CURB OR EDGE OF PAVEMENT, UNLESS NOTED OTHERWISE.
11. PAVEMENT MARKINGS SHALL BE APPLIED PER SPECIFICATIONS AND AS INDICATED BELOW:
A) PARKING SPACE MARKINGS SHALL BE 4 INCH WIDE WHITE LINES.
B) AREAS DESIGNATED AS NO PARKING WITHIN THE POV PARKING LOT SHALL BE 4 INCH WIDE YELLOW LINES MARKING ALL EDGES OF THE NO PARKING AREA, AS INDICATED ON THE SITE LAYOUT PLANS.