- Handheld X-Ray Fluorescence for ERDC GSL
- Solicitation number
- W912HZ25Q1265
About this file
This document is a detailed Request for Proposal (RFP) for a Handheld X-Ray Fluorescence (XRF) spectrometric device. The device must be field-portable, weigh 3 lbs or less, and capable of measuring elemental concentrations in soils and sediment deposits, with specific requirements including a Gold anode X-ray tube, Silicon Drift Detector, and the ability to detect a comprehensive range of elements from alkali metals to lanthanides. The XRF must have an Android-based operating system, integrated cameras, touch screen, wireless data transfer, GPS capabilities, and operate between 10°F to 130°F.
The procurement includes multiple accessories such as a battery charger, carrying case, detection standards library, laboratory and field test stands, and on-site training. Delivery is to the GSL-Airfields and Pavements Branch at CEERD-GMA in Vicksburg, MS, with a delivery deadline of March 16, 2026. Vendors must submit additional technical documentation, including manufacturer letters confirming product specifications and support capabilities. Shipping costs must be included in the quote, and the solicitation emphasizes the need for comprehensive technical support and product verification.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DESCRIPTION OF REQUIREMENTS:
Handheld-X-Ray Fluorescence (XRF)
1. Description of Requirements:
The field portable handheld-X-Ray Fluorescence (XRF) spectrometric device is required to measure and determine the presences and elemental concentrations in soils and sediment deposits. Specifically, the XRF device must be able to detect elemental distributions to identify potential rare earth ores, sensitive wasted dredged deposits, and assess the chemical makeup of in-tack and weathered geological materials. The Handheld XRF must also meet the following requirements:
a. Overall Weight: 3-lbs or less
b. Overall Dimensions: 195-in3 or less
c. Minimum X-Ray Excitation: Gold (AU) anode, 55 kV, 100 uA, 5 W X-ray Tube
d. Beam:
i. Spot Size: 4-mm
ii. Type: Fixed Collimated
e. Silicon Drift Detector (SDD):
i. Minimum Active Area Size: 50-mm2
ii. Energy Resolution: 140 eV at 5.95 Mn K-alpha line
iii. Minimum Acquisition Live Time at 250k counts per second (cps): 90%
iv. Protective Covering: Required
f. Minimum Detectable and Installed Elemental Standards for (See Table 1.):
i. Alkali Metals: Cesium (Cs), Lithium (Li), Potassium (K), Rubidium (Rb)
ii. Alkaline Earth Metals: Barium (Ba), Calcium (Ca), Magnesium (Mg)
iii. Metalloids: Antimony (Sb), Silicon (Si), Strontium (Sr)
iv. Post Transition Metals: Aluminum (Al), Arsenic (AS), Bismuth (Bi), Cadmium (Cd), Mercury (Hg), Lead (Pb), Tin (Sn), Zinc (Zn)
v. Transition Metals: Chromium (Cr), Cobalt (Co), Copper (Cu), Iron (FE), Manganese (Mn), Molybdenum (Mo), Nickel (Ni), Niobium (Nb), Silver (Ag),Tantalum (Ta), Titanium (Ti), Tungsten (W), Yttrium (Y), Vanadium (V), Zirconium (Zr)
vi. Lanthanides: Cerium (Ce), Europium (Eu), Gadolinium (Gd), Lanthanum (La), Neodymium (Nd) ,Praseodymium (Pr), Samarium (Sm)
vii. Reactive Non-Metals: Phosphorus (P), Selenium (Se) Sulfur (S)
viii. Additional Library Standards: Option to Add as Needed
g. Calibration:
i. Standards Included: Yes
ii. External Calibration Reference Material: Stainless Steel with Grade 316
iii. Calibration Method: Auto-Calibrates and Checks Calibration on 316 Grade
Stainless Steel Reference Material
Table 1: Periodic Table - Elements, Definition, Groups, Periods, Blocks. (Obtained from:
https://www.priyamstudycentre.com/chemistry/periodic-table-elements)
h. Multi-Integrated Cameras
i. Micro/Macro
ii. Targeting Crosshairs
iii. Barcode Scannable
iv. QR Code Scannale
i. Screen:
i. Flat/Flush non-flipping
ii. Touch Screen
iii. Backlit
j. Handheld XRF Operating System:
i. Android Based
ii. Does Not Require Updates
k. Software:
i. Includes PC Software for Multiple Users
ii. Does Not Require Updates
iii. Allows Operation of XRF using PC
iv. Generates Standard and Customizable Reports
v. Report Must Be Exportable in Formats: PDF and CSV https://www.priyamstudycentre.com/chemistry/periodic-table-elements
l. Data Transfer:
i. Wireless
ii. 2.0 USB
iii. SD
m. Data Acquisition Unit:
i. Minimum Processor: 1.2GHz
ii. Minimum RAM: 2GB
iii. Minimum Storage: 16GB
iv. Minimum External Storage: 32-GB
n. Built-In Connectivity: Wifi and Bluetooth
o. Geotagging with GPS Capable: Yes
p. Operating Temperature Range: 10° F to 130° F
q. Security:
i. User Level Password Protection
ii. Administrative Privileges for Settings.
r. Power:
i. Battery
ii. Hot-Swappable Battery with No Shutdown Required
iii. Rechargeable inside device
iv. External charger,
v. AC power
2. Handheld-X-Ray Fluorescence (XRF):
Equipment/Fixtures Accessory Packages Quantity
Battery Charger 1
Carrying Case 1
Detection Standards for Geo Rare Earth Elements Library 1
Benchtop Laboratory Test Stand 1
Handsfree Field Soil Test Stand 1
Closed Beam Tubular Test Stand 1
On-Site Training, Calibration, Demonstration 1
Customer Care Program (minimum 1-yr with 2-yr Extended Option Offered) 1
3. Additional Technical Documents Included In Contract Submittal Requirements:
a. Signed Letter on Manufactures Letterhead That Identifies the Submitter By Business
Name As An Approved/Registered as Primary or Reseller of Portable Handheld-XRF Devices.
b. Signed Letter on Submitter’s Letterhead Indicating the Ability To Provide Direct In-House After Sale Technical Support by Phone and Email of Portable Handheld-XRF Devices.
c. Provide Equipment Product Specifications on Manufactures Letterhead as Evidence That Proves Requirements Can Be Meet.
4. Shipping Costs:
Must Be Included in Quote.
5. Tire Pressure Mapping Sensor Pads Delivery Date:
No Later Than March 16, 2026.
6. Point of Contact and Delivery Location:
GSL-Airfields and Pavements Branch
CEERD-GMA
3909 Halls Ferry Rd Vicksburg, MS 39180-6199
File details come from the government source that posted it. Updated .