Description of Requirement
Cables Purchase
Requirement: Survivability Engineering Branch requires two sizes of instrumentation cable.
1. Specifications for nominal 1/4” Instrumentation Cable
SUMMARY: Needed an instrumentation cable with 4 conductors of 21 AWG (min.), or with equivalent Electrical Characterizes at a smaller ga. cable, Stranded (19x #34, preferred) Tinned Copper (TC, required), Polyethylene Conductor Insulation (required), with Single Braid TC Shield (24x4x #34 AWG, preferred), and PVC Jacket. Total length of 120,000-ft to be delivered in spools of continuous lengths of 2,500 to 5,000-ft.
Additional information below.
Electrical Characteristics
Voltage breakdown: Withstand 2.0kV@60Hz for 1 min.
Insulation Resistance @ 500V: 15,000 MegOhm/1000ft minimum
Shield Resistance: 10 ohm/1000ft maximum
Conductor Resistance: 15 ohm/1000ft maximum
Capacitance*@ 5kHz: Cs 23 pF/ft; Cp 43 pF/ft
*One Conductor to Other Conductors / Shield.
Physical Characteristics
Minimum Working Temperature Range: -40 to +90 deg C (required)
Conductor Color: Black, White, Red, and Green (required)
Conductor Insulation Material: Polyethylene (minimum of 0.015”thickness)
Jacket Material (Color): PVC (White or Grey)
Jacket thickness: 0.040” nominal thickness (manufactures specify tolerances)
Shield and % coverage: Single Braid TC (24x4x#34, preferred) with nominally 87% coverage or similar/equivalents will be considered
Inner Core/Cabling Configuration: Tape (between Conductors and Shield) should be a min.
of 0.001” transparent Polyester with a min. of 50% overlap.
2. Specifications for nominal 1/8” Instrumentation Cable
SUMMARY: Needed an instrumentation cable with 4 conductors of 28 AWG (min.) Stranded (7x #36, preferred) Tinned Copper (TC, required), Polyethylene Conductor Insulation (required), with Polyester, and PVC Jacket. The spool lengths 2,000 to 5,000 (total requested length delivered needs to be a min. of 20,000-ft).
Total length of 20,000-ft to be delivered in spools of continuous lengths of 2,500 to 5,000-ft. Additional information below.
Electrical Characteristics
Voltage breakdown: Withstand 1.0kV@60Hz for 1 min.
Insulation Resistance @ 500V: 15,000 MegOhm/1000ft minimum
Shield Resistance: 10 ohm/1000ft maximum
Conductor Resistance: 15 ohm/1000ft maximum
Capacitance*@ 5kHz: Cs 23 pF/ft; Cp 43 pF/ft
*One Conductor to Other Conductors / Shield.
Addition Physical Characteristics
Minimum Working Temperature Range: -40 to +90 deg C
Conductor Color: Black, White, Red, and Green (required)
Conductor Insulation Material: Polyethylene (minimum of 0.008”thickness)
Jacket Material (Color): PVC (White or Grey)
Jacket thickness: 0.019” nominal thickness (manufactures specify tolerances)
Shield and % coverage: Polyester/Aluminum foil wrap (min. thickness of 0.001”) with 100% coverage w/drain wire(s)
Delivery Location:
US Army ERDC 3909 Halls Ferry Rd Attn: CEERD-GSV, Bldg 5001
Delivery Date:
Within 8 months from award date.