W912HZ23Q0021 AMENDMENT 0002.pdf

PDF 373 KB Posted

Attached to
EnvisionTEC 3D-Bioplotter Federal contract opportunity
Solicitation number
W912HZ23Q0021
Issued by
Department of the Army Corps of Engineers Engineer Research and Development Center

About this file

This amendment to a federal solicitation extends the response deadline for solicitation number W912HZ23Q0021 to September 11, 2023 at 4:00 PM EST. The solicitation is seeking an EnvisionTEC 3D-Bioplotter for the Department of the Army Corps of Engineers Engineer Research and Development Center. The amendment answers questions by clarifying that multiwavelength photo-curing print heads, inkjet dispensing heads, ultra high temperature heads above 500 degrees Celsius, and coaxial heads are not required. However, the 2-component dispensing head that operates between 20 to 70 degrees Celsius and on-site installation, set-up, training are required to be included in the proposal.

View the file

Other files for this federal contract opportunity

Other files attached to EnvisionTEC 3D-Bioplotter, newest first.
File Type Posted
SOLICITATION NUMBER W912HZ23Q0021 AMENDMENT 0001.pdf PDF
SOLICITATION NUMBER W912HZ23Q0021.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W81EWF30876749

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

Answ er Questions and extend closing date to 09/11/2023 4:00PM EST.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 08-Sep-2023

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912HZ23Q0021

X 9B. DATED (SEE ITEM 11)

31-Aug-2023

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

08-Sep-2023

CODE

ERDC CONTRACTING OFFICE

3909 HALLS FERRY ROAD

VICKSBURG MS 39180-6199

W912HZ 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912HZ23Q0021

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION A - SOLICITATION/CONTRACT FORM

The required response date/time has changed from 08-Sep-2023 04:00 PM to 11-Sep-2023 04:00 PM.

Amendment 00002 questions and answers

Questions:

I wanted to confirm that you want these items with the initial bid?

Multiwavelength Photo-Curing Print Head w/ Auto Temp Control and LED Pen

InkJet Dispensing Head Temperature Range 25°C - 70°C

2 Component Dispensing Head Heatable (20°C - 70°C)

Ultra High Temperature Head Heatable (30°C - 500°C)

Coaxial Head Heatable and Coolable (~ 2°C - 70°C)

There are a few things which may be missing that you need to add or should add.

The first thing which is vitally important is on site installation setup and training. There is a tablet that can be purchased that contains information for others to learn how to operate the Plotter. This should be added to the bid or else be included on a separate order.

Optionally, there is a booster pump and air compressor that can be purchased. Another item that you may want to consider is a heated and cooled build plate and just wanted to make sure that this item was also considered. These are typically things that will get configured with the bio plotter when we provide them you may not need them if so these can be added later. We are looking to get it right the first time.

W912HZ23Q0021

Answer to Questions:

Multiwavelength Photo-Curing Print Head w/ Auto Temp Control and LED Pen - this is not needed

Inkjet dispensing head - this is not needed; we have multiple dispensing heads that serve as a back up for the needed research functionality

2 component dispensing head (20-70 C) - BIO-00-2021 that is requested as part of the quote will work for this function

Ultra high (30 – 500 C) – there is no need for us to go this high in temperature;

Coaxial head - not needed

Heated and cooled bed (plate) - not needed

The on site installation setup and training should be included in the quote/proposal.

(End of Summary of Changes)