W912HY19B0017- Plans - SIGNED - 2019-06-11.pdf

PDF 16 MB Posted

Attached to
Houston Ship Channel, Mid Bay Placement Area (PA) Improvements
Solicitation number
W912HY-19-B-0017
Issued by

About this file

This solicitation package describes a requirements contract for improvements to the Mid Bay Placement Area in Chambers County, Texas. The U.S. Army Corps of Engineers seeks a contractor to raise containment dikes, extend ditches, and rehabilitate two drop outlet structures at the placement area over the course of one year. Offerors must furnish bonds and begin work within ten days of notice to proceed. The estimated value ranges from $5-10 million. The NAICS code is 237990 for dredging services. Small businesses may qualify under different size standards. The solicitation will be issued on June 7th with responses due July 8th. Subcontracting goals are specified for small, small disadvantaged, women-owned small, Hubzone small, veteran-owned small, and service-disabled veteran-owned small businesses.

Plans for Mid Bay

View the file

Other files

File Type Posted
HCS Mid- Bay- ABSTRACT_W912HY19B0017b (003).pdf PDF
amend 0006.pdf PDF
AMEND-0005_W912HY19B0017.pdf PDF
AMEND-0004_W912HY19B0017.pdf PDF
Amendment No. 0003_W912HY19B0017.pdf PDF
amend_0002.pdf PDF
pdp11268.pdf PDF
W912HY19B0017Specs_-_SIGNED_-_2019-06-11.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SHEET

# of 15

DWG.

NO.

TITLE

GENERAL

1 G-001 COVER SHEET

2 G-002

INDEX OF DRAWINGS, CONTROL AND ALIGNMENT TABLES, BORING

LOCATIONS, LEGEND, AND GENERAL NOTES

3 G-003 LOCATION PLAN AND VICINITY MAP

CIVIL-SITE

4 C-101 MID BAY PLACEMENT AREA PLAN VIEW

5 C-102 MID BAY DEWATERING AREA PLAN VIEW

6 C-301 CROSS SECTIONS STA. 0+00 TO STA. 35+00

7 C-302 CROSS SECTIONS STA. 40+00 TO STA. 85+00

8 C-303 CROSS SECTIONS STA. 90+00 TO STA. 135+00

9 C-304 CROSS SECTIONS STA. 140+00 TO STA. 185+00

10 C-305 CROSS SECTIONS STA. 190+00 TO STA. 205+50

12 C-501 TYPICAL DEWATERING SECTIONS

STRUCTURAL

13 S-101 STRUCTURAL DETAILS FOR DROP OUTLET STRUCTURES

14 S-102 DROP OUTLET STRUCTURES REFERENCE DRAWING

15 S-103 DROP OUTLET STRUCTURES REFERENCE DRAWING

16 S-104 DROP OUTLET STRUCTURES REFERENCE DRAWING

15 15 -- Total Number of Drawings

INDEX OF DRAWINGS

STA. NORTHING EASTING

0+00.00 13,779,334.70 3,264,291.42 3+14.36 13,779,592.11 3,264,110.96 8+14.98 13,779,997.26 3,263,816.89

13+12.98 13,780,399.90 3,263,523.84 18+14.95 13,780,806.26 3,263,229.14 23+13.41 13,781,209.51 3,262,936.14 26+06.39 13,781,446.09 3,262,763.31 30+08.06 13,781,767.98 3,262,523.05 31+41.09 13,781,883.65 3,262,457.35 33+82.50 13,782,119.53 3,262,406.00 36+72.43 13,782,405.37 3,262,454.56 39+28.08 13,782,624.92 3,262,585.53 44+27.59 13,782,925.39 3,262,984.57 49+28.23 13,783,219.77 3,263,389.51 54+26.64 13,783,514.74 3,263,791.26 59+16.58 13,783,800.31 3,264,189.38 63+03.30 13,784,025.39 3,264,503.84 64+03.96 13,784,059.63 3,264,598.51 66+03.62 13,784,102.04 3,264,793.60 68+91.82 13,784,052.97 3,265,077.60 70+57.87 13,783,967.17 3,265,219.76 72+08.48 13,783,847.49 3,265,311.19 74+05.56 13,783,720.61 3,265,462.01 84+37.08 13,782,887.87 3,266,070.74 89+41.91 13,782,479.98 3,266,368.20 93+72.35 13,782,130.88 3,266,620.02 98+73.71 13,781,725.19 3,266,914.59

104+36.21 13,781,269.66 3,267,244.59 108+70.66 13,780,918.80 3,267,500.81 113+72.59 13,780,511.74 3,267,794.46 118+72.11 13,780,107.12 3,268,087.39 123+72.61 13,779,703.67 3,268,383.57 134+05.52 13,778,867.48 3,268,989.94 135+07.47 13,778,782.86 3,269,046.82 138+03.87 13,778,496.23 3,269,122.28 141+00.66 13,778,201.50 3,269,087.35 143+98.33 13,777,946.40 3,268,933.96 146+97.59 13,777,765.69 3,268,695.42 151+98.45 13,777,472.22 3,268,289.54 156+97.69 13,777,179.79 3,267,884.92 161+98.04 13,776,886.82 3,267,479.31 166+98.26 13,776,592.22 3,267,075.04 167+76.47 13,776,553.01 3,267,007.37 170+38.91 13,776,491.85 3,266,752.16 171+15.94 13,776,495.26 3,266,675.20 172+38.61 13,776,515.99 3,266,554.29 173+56.40 13,776,546.36 3,266,440.49 176+10.25 13,776,682.05 3,266,225.95 178+00.54 13,776,833.25 3,266,110.42 183+01.93 13,777,239.22 3,265,816.16 187+99.63 13,777,641.53 3,265,523.16 193+00.54 13,778,045.02 3,265,226.33 197+98.94 13,778,449.06 3,264,934.52 203+00.99 13,778,856.51 3,264,641.20 208+93.45 13,779,334.70 3,264,291.42 209+79.09 13,779,334.70 3,264,291.42

SURVEY BASELINE

MIDBAY P.A.

NAME PID

EASTING (X)

NAD-83 TX-SC

NORTHING (Y)

NAD-83 TX-SC

ELEV

(NAVD88)

TIDE

(MLLW)

HGCSD 55 1986 AW5666 3,254,993.224 13,753,303.287 12.62

HGCSD 53 1987 AW5664 3,233,162.677 13,774,702.451 8.29

SHELL BEACH 2014 BBDQ29 3,238,239.655 13,794,271.824 9.69

JUANITA 2014 BBDQ30 3,258,223.100 13,817,021.979 5.31

877 0907 C (Smith Point) DO9989 3,310,223.150 13,770,085.780 4.89 5.34 877 1013 A TIDAL (Eagle Point) AJ4424 3,266,697.460 13,744,960.730 4.37 4.75

CONTROL MONUMENTS

NAD83, TEXAS SOUTH-CENTRAL ZONE, US SURVEY FEET

NAME NORTHING (Y) EASTING (X)

NAD83, TEXAS SOUTH-CENTRAL ZONE, US SURVEY FEET

11-B61 13,782,790 3,262,799 11-B62 13,778,656 3,264,786 11-B63 13,776,620 3,267,114 11-B64 13,780,634 3,267,708

11-B61A 13,779,779 3,263,976 11-B64A 13,783,981 3,265,205

BORING LOCATIONS

NO. LENGTH (FT) NO. LENGTH (ft) L1 1,415 P1 5,289

L2 1,415 P2 7,896

L3 1,415 P3 7,653

L4 1,915

L5 1,415

L6 1,415

L7 1,415 L8 1,415

L9 1,415

L10 1,415

L11 1,415

L12 1,715

L13 1,815

L14 1,415

L15 1,415 L16 1,415

TOTAL PERIMETER LENGTH 20,838 (ft)

MID BAY PLACEMENT AREA

LATERAL DITCH LENGTH PERIMETER LENGTH

TOTAL LATERAL LENGTH 23,840 (ft)

001-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-01-G-01-Cover Sheet
002-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-02-G-02-INDEX
003-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-03-G-03-LOCATION PLAN
004-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-04-C-101-LAYOUT PLAN
005-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-05-C-102-PLAN-DEWATERING
006-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-06-C-301
007-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-07-C-302
008-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-08-C-303
009-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-09-C-304
010-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-10-C-305
011-HSC-401-578_CONTRACT-CIVIL-PLANS_TxSc83_2019-11-C-501-TYPICAL SECTION
012-HSC-401-578_CONTRACT-STRUCTURAL-PLANS_TxSc83_2019-12-S-101-OUTLET STRUCTURE
013-HSC-401-578_CONTRACT-STRUCTURAL-PLANS_TxSc83_2019-13-S-102-OUTLET STRUCTURE
014-HSC-401-578_CONTRACT-STRUCTURAL-PLANS_TxSc83_2019-14-S-103-OUTLET STRUCTURE
015-HSC-401-578_CONTRACT-STRUCTURAL-PLANS_TxSc83_2019-15-S-104-OUTLET STRUCTURE
2019-06-11T11:09:56-0500
HONZA.WILLIE.J.1231036136

File details come from the government source that posted it. Updated .