W912HV-17-R-0005
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
B. CHANGES TO SOLICITATION:
b. Revised Pages/Paragraphs: Attached hereto are revised pages/paragraphs added to the solicitation. The revision mark (Am-0001) is shown on each new page of the specifications. Changes are indicated by an asterisk in the left margin opposite the beginning of the revision and an asterisk in the right margin opposite the end of the revision.
Section Page No(s)/Paragraph No(s) B – (Supplies or Services and Prices) Pages 2 – 6
C – (Description and Specifications) Pages 43 - 47 Technical Exhibit 7
C. QUESTIONS AND ANSWERS: The Government’s response(s) to question(s) submitted by prospective bidder(s)/offeror(s) are provided below. Questions/Answers 1-15. The following questions were submitted by potential offeror (s). Answers provided below do not amend the solicitation unless specifically noted and incorporated into the solicitation through a revision to the solicitation’s specifications or drawings.
1. Regarding the past experience, the contract specification shows project must have a total minimum value of at least 50,000,000yen. Please advise if it means one contract value for one year or several years like 5 years contract?
A1: Please see Section L, paragraph II.B for the definition of a project, as there are no specific parameters as to the time/duration of a project.
2. Please provide layout drawings for HVAC and refrigeration system per building.
A2: Please see Section C, PWS paragraph 20.10.3 regarding the status of equipment. Drawings and As-builts will be provided to the successful offeror.
3. Please provide As Built drawings after renovation of the system.
A3: Please see Section C, PWS paragraph 20.10.3 regarding the status of equipment. Drawings and As-builts will be provided to the successful offeror.
4. Technical Exhibit 7 Equipment List Page C-35 Sys: S/C, Circuit: SC-1, QTY: 1,ID: 1G24,Model: Hill Phoenix CF-S, Description: 8' Grab and Go Case. Where is this unit? It could not be found at the Atsugi Commissary.
A4: The “8’ Grab and Go Case” has been deleted from Technical Exhibit 7 – Equipment List.
5. Technical Exhibit 7 - Equipment List Page C-36. Are the equipment listed on this page a duplicate of the equipment listed on Page C-35?
A5: Duplicated information has been deleted.
6. Technical Exhibit 7 - Equipment List Page C-37, Qty: 1, ID: ID14A Model: Henny Penny Hot Food Merchandiser 120/208V, 3.17KW, 15.2A Description: Sales Area. This is not HVAC&R equipment. Will this equipment be included in the contract?
A6: Non-HVAC & refrigeration equipment has been deleted.
7. Technical Exhibit 7 - Equipment List Page C-38, Sys: PMS, QTY: 1, ID: 1, Model: Produce Misting System, Description: Produce Misting System. Is there a misting system for the SFHA Commissary?
A7: A misting system was not installed, and has been deleted from Technical Exhibit 7 – Equipment List.
8. Technical Exhibit 7 - Equipment List Page C-39. Are there 2 outdoor Daikin Heat Pump Units and 2 Blower Coils for the ADEP Room? We could only locate 1 of each.
Qty: 1 ID: PAC-1 Model: Daikin Heat Pump Description: Lower Rooftop (Front) Qty: 1 ID: PAC-5 Model: Daikin Heat Pump Description: Lower Rooftop (Front) Qty: 1 ID: BC-1 Model: Blower Coil Description: ADEP Room - Rm7 Qty: 1 ID: BC-4 Model: Blower Coil Description: ADEP Room - Rm 7
A8: Locations for PAC-4 Daikin Heat Pump and BC-4 Blower Coil have been updated on revised equipment list.
There is no PAC-5 in the Equipment List.
9. Technical Exhibit 7 - Equipment List Page C-39, Qty: 1, ID: KEF-1 Model: Kitchen Exhaust Ventilation-Direct- Greenheck, Description: Upper Roof over Deli Service Area. Is the contractor required to clean the grease on the ventilator?
A9: Maintenance of kitchen exhaust is covered as "exhaust fans" under 20.3. COMMISSARY HVAC SYSTEM, includes motor, bearings, etc. Grease cleaning is not included.
10. Technical Exhibit 7 - Equipment List Page C-39, QTY: 1 ID: KH-1 Model: Kitchen Hood with Type 1 Fire Suppresion-Greenheck GHEW Description: Deli - Clean Quarterly. Is the contractor required to clean the Kitchen Hood and duct? If yes, is there an access to clean the inside of the duct? Is the contractor required to maintain the Type 1 Fire Suppression System?
A10: Maintenance of "kitchen hood and duct" is covered as "exhaust fans" and "duct insulation and supports" under
20.3. COMMISSARY HVAC SYSTEM which includes motor, bearings, etc. Grease cleaning of the hood and duct is not included in the maintenance contract. Maintenance of the Kitchen Hood with Type 1 Fire Suppression System is not included under this contract and will be removed from the Technical Exhibit 7 – Equipment List
11. Technical Exhibit 7 - Equipment List Page C-39, QTY: 1, ID: GT Model: Kitchen Grease Trap – UNK, Description: GT: Deli - Clean Quarterly. This is not a HVAC & Refrigeration equipment. Will this be included in the contract?
A11: Non-HVAC & refrigeration equipment has been deleted from the Technical Exhibit 7 – Equipment List.
12. Technical Exhibit 7 Equipment List Page C-39 QTY: 1 ID: HP1 Model: Heat Pump Outdoor Description: Warehouse S3 - Roof QTY: 1 ID: HP2 Model: Heat Pump Outdoor Description: Warehouse S3 - Roof QTY: 1 ID: HP3 Model: Heat Pump Outdoor Description: Warehouse S3 – Roof
Where are these units? The units could not be found at the SFHA Commissary S3.
A12: Equipment has been deleted from Technical Exhibit 7 - Equipment List.
13. Technical Exhibit 7 - Equipment List Page C-39, QTY: 33, ID: UH1 -33, Model: Unit Heater, Ceiling Hung - Fractional Hp, Description: Warehouse S3. These unit heaters are not in use and a modification was issued to remove the units under contract W912HV-13-C-0003. Will these units be included in this contract?
A13: Equipment has been deleted from Technical Exhibit 7 - Equipment List.
14. Technical Exhibit 7 Equipment List Page C-40, Sys: UC-ect, QTY: 1 Model: Walk-in Reefer Unit Cooler with Outdoor Condenser - Old Description: Mitsubishi - 7.5KW. Where are these equipment? These equipment could not be found at Cp Zama Commissary.
A14: Equipment has been deleted from Technical Exhibit 7 - Equipment List.
15. Page C-8 Section 17.23 Emergency Calls: "Commissary personnel must verify that display cases are indeed malfunctioning when a high limit is exceeded and are not just in defrost." Is our understanding that the Commissary Personnel is responsible to physically or visually verify that the equipment is in alarm prior to requesting an Emergency Call 24/7?
A15: Performance Work Statement will be followed as stated.
SECTION B - SUPPLIES OR SERVICES AND PRICES
The following have been modified:
Maintenance and Repair of Refrigeration and HVAC Systems, Commissaries Kanto Area, Japan
Base Year: 1 Sept 2017 to 31 Aug 2018
UNIT
ITEM
NO. SUPPLIES/SERVICES QTY UNIT PRICE AMOUNT
0001 Monthly Preventive, Emergency Maintenance and Repair of Refrigeration Systems and associated Refrigeration Monitoring and Control Systems
0001AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
0001AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
0001AC Sagamihara FHA Warehouse (Bldg S-3) 12 MO ¥_________ ¥__________
0001AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
0002 Monthly Preventive, Emergency Maintenance and Repair of HVAC Systems
0002AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
0002AB Sagamihara FHA Commissary (Bldg -104) 12 MO ¥_________ ¥__________
0002AC Sagamihara FHA Warehouse (Bldg S-3) 12 MO ¥_________ ¥__________
0002AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
0003 Reimbursable Items 1 Year NTE ¥1,500,000
0004 Contract Manpower Reporting 1 Job ¥_________ ¥__________
Subtotal of Base Year: ¥___________
Maintenance and Repair of Refrigeration and HVAC Systems, Commissaries Kanto Area, Japan
Option Year 1: 1 Sept 2018 to 31 Aug 2019
UNIT
ITEM
NO. SUPPLIES/SERVICES QTY UNIT PRICE AMOUNT
1001 Monthly Preventive, Emergency Maintenance and Repair of Refrigeration Systems and associated Refrigeration Monitoring and Control Systems
1001AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
1001AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
1001AC Sagamihara FHA Warehouse (Bldg S-3) 12 MO ¥_________ ¥__________
1001AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
1002 Monthly Preventive, Emergency Maintenance and Repair of HVAC Systems
1002AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
1002AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
1002AC Sagamihara FHA Warehouse (Bldg S-3) 12 MO ¥_________ ¥__________
1002AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
1003 Reimbursable Items 1 Year NTE ¥1,500,000
1004 Contract Manpower Reporting 1 Job ¥_________ ¥__________
Subtotal of Option Year 1: ¥___________
Maintenance and Repair of Refrigeration and HVAC Systems, Commissaries Kanto Area, Japan
Option Year 2: 1 Sept 2019 to 31 Aug 2020
UNIT
ITEM
NO. SUPPLIES/SERVICES QTY UNIT PRICE AMOUNT
2001 Monthly Preventive, Emergency Maintenance and Repair of Refrigeration Systems and associated Refrigeration Monitoring and Control Systems
2001AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
2001AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
2001AC Sagamihara FHA Warehouse (Bldg S-3) 12 MO ¥_________ ¥__________
2001AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
2002 Monthly Preventive, Emergency Maintenance and Repair of HVAC Systems
2002AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
2002AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
2002AC Sagamihara FHA Warehouse Bldg S-3 12 MO ¥_________ ¥__________
2002AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
2003 Reimbursable Items 1 Year NTE ¥1,500,000
2004 Contract Manpower Reporting 1 Job ¥_________ ¥__________
Subtotal of Option Year 2: ¥___________
Maintenance and Repair of Refrigeration and HVAC Systems, Commissaries Kanto Area, Japan
Option Year 3: 1 Sept 2020 to 31 Aug 2021
UNIT
ITEM
NO. SUPPLIES/SERVICES QTY UNIT PRICE AMOUNT
3001 Monthly Preventive, Emergency Maintenance and Repair of Refrigeration Systems and associated Refrigeration Monitoring and Control Systems
3001AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
3001AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
3001AC Sagamihara FHA Warehouse (Bldg S-3) 12 MO ¥_________ ¥__________
3001AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
3002 Monthly Preventive, Emergency Maintenance and Repair of HVAC Systems
3002AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
3002AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
3002AC Sagamihara FHA Warehouse Bldg S-3 12 MO ¥_________ ¥__________
3002AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
3003 Reimbursable Items 1 Year NTE ¥1,500,000
3004 Contract Manpower Reporting 1 Job ¥_________ ¥__________
Subtotal of Option Year 3: ¥___________
Maintenance and Repair of Refrigeration and HVAC Systems, Commissaries Kanto Area, Japan
Option Year 4: 1 Sept 2021 to 31 Aug 2022
UNIT
ITEM
NO. SUPPLIES/SERVICES QTY UNIT PRICE AMOUNT
4001 Monthly Preventive, Emergency Maintenance and Repair of Refrigeration Systems and associated Refrigeration Monitoring and Control Systems
4001AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
4001AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
4001AC Sagamihara FHA Warehouse Bldg S-3 12 MO ¥_________ ¥__________
4001AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
4002 Monthly Preventive, Emergency Maintenance and Repair of HVAC Systems
4002AA Atsugi NAF Commissary (Bldg 1306) 12 MO ¥_________ ¥__________
4002AB Sagamihara FHA Commissary (Bldg S-104) 12 MO ¥_________ ¥__________
4002AC Sagamihara FHA Warehouse (Bldg S-3) 12 MO ¥_________ ¥__________
4002AD Camp Zama Commissary (Bldg 690) 12 MO ¥_________ ¥__________
4003 Reimbursable Items 1 Year NTE ¥1,500,000
4004 Contract Manpower Reporting 1 Job ¥_________ ¥__________
Subtotal of Option Year 4: ¥___________
BASE YEAR SUBTOTAL ¥_____________
OPTION YEAR 1 SUBTOTAL ¥_____________
OPTION YEAR 2 SUBTOTAL ¥_____________
OPTION YEAR 3 SUBTOTAL ¥_____________
OPTION YEAR 4 SUBTOTAL ¥_____________
GRAND TOTAL AMOUNT ¥_____________
Sys Circuit QTY ID Model (See Equipment Schedule) Description CS-1 1 1 UC-1 BOHN Unit Cooler - LLE-204 1/2 FF Storage RM 135 CS-1 2 1 UC-2 BOHN Unit Cooler - LLE-204 1/2 FF Storage RM 135 CS-1 3 3 1G12 Hill Phoenix - 15DR-ORZ & EZM Glass Door I/C Case - 5 Doors (3 EA) CS-1 4 2 1G10 Hill Phoenix - 8DR-ORZ & EZM Glass Door I/C Case - 5 Doors (1 EA) & 3 Doors (1 EA) CS-1 5 2 1G10 Hill Phoenix - 10DR-ORZ & EZM Glass Door I/C Case - 5 Doors (2 EA) CS-1 6 2 1G10 Hill Phoenix - 13DR-ORZ & EZM Glass Door I/C Case - 3 Doors (1 EA) & 5 Doors (2 EA) CS-1 7 2 1G10 Hill Phoenix - 13DR-ORZ & EZM Glass Door I/C Case - 3 Doors (1 EA) & 5 Doors (2 EA) CS-1 8 2 1G10 Hill Phoenix - 13DR-ORZ & EZM Glass Door I/C Case - 3 Doors (1 EA) & 5 Doors (2 EA) CS-1 9 2 1G06/07 Hill Phoenix - 16' ONZ + OWEZ END CAPS 8' W/ END CAPS (2 EA) CS-1 10 spare CS-2 11 1 UC-3 BOHN Unit Cooler - LET-280 Meat Storage Rm 136 (1 EA) CS-2 12 1 UC-4 BOHN Unit Cooler - ADT-260 Meat Prep Rm 137 (1 EA) CS-2 13 1 UC-5 BOHN Unit Cooler - ADT-130 Meat Wrap Rm 138 (1 EA) CS-2 14 4 1GDD/!G02 Hill Phoenix - 48'-ORB-PV 12' Dairy (12-Doors) (4 EA) CS-2 15 2 1GDD/!G03 Hill Phoenix - 24'-ORB-PV 12' Dairy (12-Doors) (2 EA) CS-2 16 2 1M07 Hill Phoenix - 24'-OHMH 12' Multi Deck Meat (2 EA) CS-2 17 1 1B30 Hill Phoenix - 77"-BLF-77SR 77" Serv Bky (1 EA) CS-2 18 1 1D00 Hill Phoenix - 12' SSA 12' Service Deli (1 EA) CS-2 19 2 1GDD/1M04 Hill Phoenix - 20'-ORB-PV 8' (1 EA) + 8 Doors - 12' Dairy (1 EA) CS-2 20 1 UC-6 BOHN unit Cooler - ADT-260 Dairy Chill Rm 133 (1 EA) CS-2 21 1 UC-7 BOHN Unit Cooler - ADT-156 Produce Storage Rm 132 (1 EA) CS-2 22 2 UC-8/UC-9 BOHN Unit Cooler - ADT-130 Produce Chill (Gas) Rm 131 (2 EA) CS-2 23 2 1P03 Hill Phoenix - 16' OHP 8' MD Produce (2 EA) CS-2 24 3 1P03 Hill Phoenix - 28' OHP 8' (2 EA) + 12 FT MD Produce (1 EA) CS-2 25 1 1P07 Hill Phoenix - 12'-ORB-PV 12' Cut Produce (1 EA) CS-2 26 1 CS-1 Hill Phoenix CS-1 Rack CS-1 Sub-Cooler CS-2 27 Spare CU-1 28 1 UC 10 BOHN Unit Cooler - BML-220 FF Storage Rm 68B (1 EA)
S/C SC-1 1 1G24 Hill Phoenix - CF-S 8' GRAB AND GO CASE S/C SC-2 1 Southern - MDC-78HN-4' 4' Grab and Go S/C SC-3 1 Ice Maker S/C Produce - Hoshizaki 208 volts PMS 1 Produce Misting System Produce Misting System
RMCS1 1 DANFOSS - 2DB3F25KL-TFC-C41 Refrigeration Monitoring System and Controls RMCS2 1 DANFOSS - 2DB3F25KL-TFC-C41 Refrigeration Monitoring System and Controls RMCS3 1 DANFOSS - 3DA3R10ML-TFC-C41 Refrigeration Monitoring System and Controls RMCS4 1 DANFOSS - 3DF4S11ML-TFC-C41 Refrigeration Monitoring System and Controls HRC-1 CS-3 1 AHU1 HR1 - Hot Gas Reclaim (96.6 MBH) Air Heat Reclaim 1 HRT CS-2 1 HW Tank Thermo-Stor 432 liters Capacity - TS-II-120-2-A HW Tank
UC-ext 1 Walk-In Reefer Unit Cooler wth Outdoor Condenser - Old Mitsubishi-7.5KW
ACC1 1 BOHN - BNX-D04-A026 Condenser for Rack 1 241 MBH ACC2 1 BOHN - BNX-D06-A039 Condenser for Rack 2 543 MBH
CS1 1 CS1 - 1@2DL3F20KL + 3@3DF3F40KL-TFC Low Temperature Rack - Refrigerant 407A CS2 1 CS2 - 1@2DA3R89KL-TFC + 3@3DS4S12KL-TFC Med Temperature Rack - Refrigerant 407A CU-1 1 BDT0400L 2DL3F20KL-TFC 18.2 MBH -Ground Chiller
Sys Circuit QTY ID Model (See Equipment Schedule) Description ACCH-1 1 UNK Japanese-UWVA2360B5/B6 - 80 HP - 265 KW Air Cooled Chilling Unit ACU-1 1 UNK Japanese AHU - 204 KW Air Handling Unit RH-1 1 Heat Reclaim Coil - Duct Mounted Circuit C-2
PAC-1 1 Split Type Heat Pump Unit - RM 108 W/Remote Outdoor Unit - 5.6 KW CWP-1 2 Teral-Chilled Water Circulating Pump - 760 L/min Mech Rm CWP-2 2 Teral -Condensing Water Circulating Pump - 7.5KW Mech Rm HWP-1 2 Teral-Hot Water Circulating Pump - 3.7 KW Mech Rm EXC-1 1 Steam Water Heat Exchanger - 281,000 kcal/hr Mech Rm HWT-1 1 Hot Water Generator - 128,000 kcal/hr Mech Rm
FCU1-10 10 Fan-Coil Units - Ceiling Mounted - Fractional hp Various HEX1-10 10 Heat Exchange Ventilation Units - Fractional hp Various EF1-10 10 Ceiling Exhaust Fans - Fractional hp Various UH1-5 5 Unit Heaters - Ceiling Hung - Fractional hp Various
HTR1-6 6 Convector Heaters - Floor mtd - Showa Floor Mounted - Fractional hp SA-1 1 Fresh Air In-take Fan - Ceiling Mtd - Fractional hp Electrical Rm
AC 1-8 8 Air Curtains - Mistubishi - Fractional hp Reefers and roll-up doors CWH1-2 2 Chilled Water Header - Floor Mounted Mechanical Rm STH-1 1 Steam Header - Floor Mounted Mechanical Rm EXT-1 1 Expansion Tank - Ceiling Hung Mechanical Rm EF1-2 2 Wall Exhaust Fan - Fractional Hp Mechanical Rm a 404A b Protocall Rack c New Added Rack
Atsugi Commissary Refrigerated Equipment & HVAC List
Additional Equipment
Air Cooled Condensers
Compressor Racks
Refrigeration Equipment
HVAC Equipment
W912HV-17-R-0005
C - 35
Sys Qty ID Model Description CS-1 1 UC-1 Hill Phoenix - Unit Cooler WH Cold-Storage - Rm 68C CS-1 1 UC-2 Hill Phoenix - Unit Cooler WHCold-Storage - Rm 68C CS-1 1 UC-4 Hill Phoenix - Unit Cooler WH Cold-Storage - Rm 68B CS-1 1 UC-5 Hill Phoenix - Unit Cooler WH Cold-Storage - Rm 68B CS-2 1 UC-18 Hill Phoenix - Unit Cooler WH Cold-Storage - Rm 77 CS-2 1 UC-19 Hill Phoenix - Unit Cooler WH Cold-Storage - Rm 77
ACC-3 2 Russell RILS400H22-E - Condensing Unit -Chill Box Warehouse S3 ACC-4 2 Russell DLD5L44E-Condensing Unit - Freeze Box Warehouse S3
UC-ACC3 4 Unit Coolers for ACC3 - Chill Box Warehouse S3 UC-ACCR 4 Unit Coolers for ACCR - Freeze Box Warehouse S3
Sys Qty ID Model Description CS-1 1 UC-3 Hill Phoenix - Unit Cooler Frozen Food Storage - Rm 68A CS-2 1 UC-6 Hill Phoenix - Unit Cooler 208-230V, 1A Dairy Chill Storage - Rm 67 CS-2 1 UC-7 Hill Phoenix - Unit Cooler 208-230V, 1A Dairy Chill Storage - Rm 67 CS-2 1 UC-8 Hill Phoenix - Unit Cooler 208-230V, 1A Dairy Chill Storage - Rm 67 CS-2 1 UC-9 Hill Phoenix - Unit Cooler Meat Chill Storage - Rm 59 CS-2 1 UC-10 Hill Phoenix - Unit Cooler Meat Chill Storage - Rm 59 CS-2 1 UC-11 Hill Phoenix - Unit Cooler Chicken Processing - Rm 32 CS-2 1 UC-12 Hill Phoenix - Unit Cooler Meat Processing - Rm 55 CS-2 1 UC-13 Hill Phoenix - Unit Cooler Meat Processing - Rm 55 CS-2 1 UC-14 Hill Phoenix - Unit Cooler Produce Processing - Rm 44A CS-2 1 UC-15 Hill Phoenix - Unit Cooler Produce Chilled Storage - Rm 43A CS-2 1 UC-16 Hill Phoenix - Unit Cooler Produce Chilled Storage - Rm 43B CS-2 1 UC-17 Hill Phoenix - Unit Cooler Produce Chilled Storage - Rm 43C CS-1 1 ICGD1-07 Hill Phoenix - Showcase 120V, 10.39A / 208V, 12.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 ICGD2-07 Hill Phoenix - Showcase 120V, 8.37A / 208V, 14.35A Sales - Rm 69A / Glass Door Case - 4 Doors CS-1 1 FZGD1-01 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD2-01 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD3-01 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD4-01 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD1-04 Hill Phoenix - Showcase 120V, 9A / 208V, 14.35A Sales - Rm 69A / Glass Door Case - 4 Doors CS-1 1 FZGD2-04 Hill Phoenix - Showcase 120V, 6.32A / 208V, 10.93A Sales - Rm 69A / Glass Door Case - 3 Doors CS-1 1 SDFF2-08 Hill Phoenix - Showcase 120V, 1.62A / 208V, 8.65A Sales - Rm 69A / Coffin Type Case CS-1 1 SDFF3-08 Hill Phoenix - Showcase 120V, 2.67A / 208V, 11.55A Sales - Rm 69A / Coffin Type Case CS-1 1 SDFF1-08 Hill Phoenix - Showcase 120V, 2.67A / 208V, 11.55A Sales - Rm 69A / Coffin Type Case CS-1 1 FZGD1-02 Hill Phoenix - Showcase 120V, 6.32A / 208V, 10.93A Sales - Rm 69A / Glass Door Case - 3 Doors CS-1 1 FZGD2-02 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD3-02 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD4-02 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 PKDL1-17 Hill Phoenix - Showcase 120V, 4.93A Sales - Rm 69A / Glass Door Case - 4 Doors CS-1 1 FZGD1-03 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD2-03 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD3-03 Hill Phoenix - Showcase 120V, 10.39A / 208V, 17.5A Sales - Rm 69A / Glass Door Case - 5 Doors CS-1 1 FZGD4-03 Hill Phoenix - Showcase 120V, 6.32A / 208V, 10.93A Sales - Rm 69A / Glass Door Case - 3 Doors CS-2 1 DELI1-11 Hill Phoenix - Showcase 120V, 2.36A Sales - Rm 69A CS-2 1 PKDL2-17 Hill Phoenix - Showcase 120V, 4.93A Sales - Rm 69A / Glass Door Case - 4 Doors CS-2 1 DYCS3-19 Hill Phoenix - Showcase 120V, 4.93A Sales - Rm 69A / Glass Door Case - 4 Doors CS-2 1 DYCS2-19 Hill Phoenix - Showcase 120V, 4.93A Sales - Rm 69A / Glass Door Case - 6 Doors CS-2 1 DYCS1-19 Hill Phoenix - Showcase 120V, 4.23A Sales - Rm 69A / Glass Door Case - 6 Doors CS-2 1 DYCS3-18 Hill Phoenix - Showcase 120V, 4.23A Sales - Rm 69A / Glass Door Case - 6 Doors CS-2 1 DYCS2-18 Hill Phoenix - Showcase 120V, 4.23A Sales - Rm 69A / Glass Door Case - 4 Doors CS-2 1 DYCS1-18 Hill Phoenix - Showcase 120V, 4.93A Sales - Rm 69A / Glass Door Case - 6 Doors CS-2 1 MDDI1-22 Hill Phoenix - Showcase Sales - Rm 69A / Glass Door Case - 4 Doors CS-2 1 MDDI2-22 Hill Phoenix - Showcase Sales - Rm 69A CS-2 1 MTCS1-12 Hill Phoenix - Showcase Sales - Rm 69A CS-2 1 MTCS2-12 Hill Phoenix - Showcase Sales - Rm 69A CS-2 1 PRCS1-21 Hill Phoenix - Showcase Sales - Rm 69A CS-2 1 PRCS2-21 Hill Phoenix - Showcase Sales - Rm 69A CS-2 1 PRCS1-20 Hill Phoenix - Showcase Sales - Rm 69A CS-2 1 PRCS2-20 Hill Phoenix - Showcase Sales - Rm 69A CS-2 1 PRCS3-20 Hill Phoenix - Showcase Sales - Rm 69A CS-1 1 Hill Phoenix - Refrigeration Rack Enclosure 208V, 211.8A Lower Rooftop (Back) CS-2 1 Hill Phoenix - Refrigeration Rack Enclosure 208V, 177A Lower Rooftop (Back)
ACC-1 1 Hill Phoenix - Condenser 208-220V, Lower Rooftop (Back) ACC-2 1 Hill Phoenix - Condenser 208-220V, Lower Rooftop (Back)
1 1D042 Hoshizaki Refrigerator 1PH 100V 50HZ (9.0A) Sef Contained Rm 70 Deli Service Area 1 4IFNIS Hoshizaki Ice Flaker 3PH 200V 50HZ (5.5A) Rm 44A Produce Preparation 1 1D14A Henny Penny Hot Hood Merchandiser 120/208V,3.17kW, 15.2A Sales Area 1 1G24 Federal Industry 1HP, 15AMP Self Contained Checkout Grab&Go
PMS 1 1 Produce Misting System Produce Misting System
Refrigeration Equipment Bldg S-104 (Commissary)
Refrigeration Equipment Bldg S-3 (Warehouse) SFHA Commissary Refrigerated Equipment List
W912HV-17-R-0005
C - 36
Sys Qty ID Model Description Refrigeration Equipment Bldg S-3 (Warehouse)
SFHA Commissary Refrigerated Equipment List
RMCS1 1 1 DANFOSS - 2DB3F25KL-TFC-C41 Refrigeration Monitoring System and Controls RMCS2 1 1 DANFOSS - 2DB3F25KL-TFC-C41 Refrigeration Monitoring System and Controls RMCS3 1 1 DANFOSS - 3DA3R10ML-TFC-C41 Refrigeration Monitoring System and Controls RMCS4 1 1 DANFOSS - 3DF4S11ML-TFC-C41 Refrigeration Monitoring System and Controls
W912HV-17-R-0005
C - 37
Qty ID Model Description 4 Convector Convector Floor Mounted - Showa Warehouse S3 - See HVAC Drwgs 2 Wvent Wall Ventilator - Unknown Warehouse S3 Restrooms
33 UH1-33 Unit Heater, Ceiling Hung - Fractional Hp Warehouse S3
Qty ID Model Description 1 MAU-1 Seasons-4 Inc. - Make Up Air Unit 208V Lower Rooftop (Back) 1 CU-1 Carrier - Condensing Unit 400V, 10.90kW Lower Rooftop (Back) 1 CU-2 Carrier - Condensing Unit 400V, 4.20kW Lower Rooftop (Back) 1 AHU-1 Air Zone International - Air Handling Unit 208V, 15HP (11.2kW) Mech Room - Rm 31C 1 AHU-2 Air Zone International - Air Handling Unit 208V, 5HP (3.7kW) Mech Room - Rm 31C 1 HRC-1 Heat Reclaim Coil for AHU-1 CS-2 (61.1 KWh) 1 HRC-2 Heat Reclaim Coil for AHU-2 CS-1 (16.3 KWh) 1 CUH-1 Showa - Cabinet Unit Heater 1PH 120V 50HZ 3.62kW Patron Restroom (Women) - Rm 11 1 CUH-2 Showa - Cabinet Unit Heater 1PH 120V 50HZ 3.62kW Patron Restroom (Men) - Rm 10 1 CUH-3 Showa- Cabinet Unit Heater 1PH 120V 50HZ 3.62kW Employee Restroom (Women) - Rm 26A 1 CUH-4 Showa - Cabinet Unit Heater 1PH 120V 50HZ 3.62kW Employee Restroom (Men) - Rm 27A 1 PAC-1 Daikin - Heat Pump Unit 3PH 208V 50HZ R32 Lower Rooftop (Front) - See HVAC Drwgs 1 PAC-4 Daikin - Heat Pump Unit 3PH 208V 50HZ R33 Lower Rooftop (Front) - See HVAC Drwgs, Room 9, ATM 1 BC-1 Daikin - Blower Coil 3PH 208V 50HZ R32 ADEP Room - Rm 7 - See HVAC Drwgs 1 BC-4 Daikin - Blower Coil 3PH 208V 50HZ R33 Lower Rooftop (Front) - See HVAC Drwgs Room 9, ATM 1 KEF-1 Kitchen Exhaust Ventilation-Direct - Greenheck- 1PH 115V/7.6FLA Upper Rooftop over Deli Service Area 1 KH-1 Kitchen Hood with Type 1 Fire Suppression - Greemheck GHEW Deli - Clean Quarterly 1 GT Kitchen Grease Trap - UNK Deli - Clean Quarterly 8 CEF1-8 Ceiling Exhaust Fans - Mitsubishi Fractional Hp - Various Locations - See HVAC Drwgs 1 WEF Wall Exhaust Fan - Unkown Fractional Hp - Mechanical Room - See HVAC Drwgs
5 VF1-5 Ventilation Fans - Ceiling - Fractional - Admin Admin Area - See HVAC Dwgs for Locations 1 AD-1 Mars - Air Door 120V, 50Hz, 2.6A Entry Vestibule - Rm 1 1 AD-2 Mars - Air Door 120V, 50Hz, 2.6A Entry Vestibule - Rm 1 1 AD-3 Mars - Air Door 120V, 50Hz, 2.6A Checkout - Rm 81 4 Mitsubishi - Air Curtain Receiving Aisle - Rm 54
HVAC Equipment S-3 (Warehouse) SFHA Commissary Refrigerated Equipment List
HVAC Equipment Bldg S-104 (Commissary)
W912HV-17-R-0005
C - 38
Sys Circuit QTY ID Model (See Equipment Schedule) Description CS-1 4 1 UC1-1 Tyler Unit Cooler - AE44-14OLD 1/2 Grocery Freezer - RM68 CS-1 4 1 UC2-1 Tyler Unit Cooler - AE44-14OLD 1/2 Grocery Freezer - RM68 CS-1 1 2 1G12 Tyler N5FGNA NAR ICE CREAM DRS Glass Door I/C Case - 10 Doors CS-1 2 2 1G12 Tyler N5FGNA NAR FROZEN FOOD DRS Glass Door I/C Case - 10 Doors CS-1 3 3 1G12 Tyler N5FGNA NAR FROZEN FOOD DRS Glass Door I/C Case - 15 Doors CS-2 11 1 UC3-2 Tyler Unit Cooler - AA46-230MA Chilled Storage Room - RM59 CS-2 12 1 UC4-2 Tyler Unit Cooler - AA36-145MA Dairy Cooler - RM67 CS-2 12 1 UC5-2 Tyler Unit Cooler - AA36-145MA Dairy Cooler - RM68 CS-2 13 1 UC6-2 Tyler Unit Cooler - FL46-180MA Food Prep Area - RM44 CS-2 5 3 1G13 Tyler N6DH6 Deli 6 Deck High Fr Glass Door Case - 12 Doors CS-2 6 3 1G13 Tyler N5MG Meat 5 Deck GL FR Glass Door Case - 12 Doors CS-2 7 1 1G02 Tyler N6DH6 Dairy 6 Deck Low FRT Multideck Merchandiser - 24 Doors CS-3 8 6 1P02 Tyler N4P Produce 4 Deck Multideck Merchandiser- 24 Doors CS-2 9 3 1P07 Tyler N6DL PROD 6 DECK LOW FRT Multideck Merchandiser - 12 Doors CS-2 10 3 1G02 Tyler N6DH6 Dairy 6 Deck Low FRT Multideck Merchandiser - 12 Doors
S/C SC-1 1 LMC600 Portable Freezer S/C SC-2 1 Portable freezer-STANDEX SERIAL# 006837 MODEL# LPortable Freezer S/C SC-3 1 Portable freezer-STANDEX SERIAL# PU471569 MODELPortable Freezer S/C SC-4 1 Reach-in Refrigerator - Food Processing Room Portable Refrigerator S/C SC-5 1 Ice Flaker - Cornelius Ice Flaker
RMCS1 2 COMTROL Mechanical Room
ACC1 1 NAC-59 Condenser for Rack 1 222,140 BTUH ACC2 1 NAC63 Condenser for Rack 2 371,642 BTUH
CS1 1 Tyler Scroll Compressor Rack Low Temperature Rack - Refrigerant 404A CS2 1 Tyler Scroll Compressor Rack Med Temperature Rack - Refrigerant 404A
UC-ext 1 Walk-In Reefer Unit Cooler wth Outdoor Condenser - Old Mitsubishi-7.5KW
AH-1 1 McQuay Packaged Air Handler Unit - Sales Area Cooling Cap= 49.518 Kcal/h; Air Volume 2.360 L/s- R22 - 200/50/3-6.7/10 Hp ACP-1 1 Daikin Packaged Air Handler Unit - Admin 5520/6510 Kcal/h,40L/min-R22 - 2.2KW-200/50/3 HS-1 1 Steam Heat Exchanger for ACP-1 0.35 Kg/cm3 HC-1 1 Heat Coil - Sankyo 103 KW CT-1 1 Cooling Tower - for ACP-1 10.800 Kcal/H PV-1 1 Condenser for Heat Exchanger - Ebara Mech Rm
PCD-1 1 Condenser Water Circulating Pump - Ebara Mech Rm UH1-4 4 Unit Heaters Warehouse - Ceiling Hung - Fractional hp Warehoue
HP 2 Heat Pump Split System - Toshiba 40 KW RM22 HTR 2 Heater - Electric - 1.5 KW RMS 10 & 11, Restrooms
EF1-8 8 Exhaust Fans - Mitsubishi 180 m3/Hr EXH-1 1 Louvers Exhaust System Mechanical Rm RMCS 1 RMCS - COMTROL Mechanical Rm EXT-1 1 Expansion Tank - Ceiling Hung Mechanical Rm EF1-2 2 Wall Exhaust Fan - Fractional Hp Mechanical Rm
HVAC a 404A b Protocall Rack c New Added Rack
Compressor Racks
Camp Zama Commissary Refrigerated Equipment & HVAC List
Additional Equipment
Air Cooled Condensers
Refrigeration Equipment
HVAC Equipment
W912HV-17-R-0005
C - 38