W912HN19B3005_AMD3.PDF
PDF 352 KB Posted
- Solicitation number
- W912HN19B3005
About this file
Drawings
View the file
Other files
| File | Type | Posted |
|---|---|---|
| C.04.01_W912HN19B3005_Abstract_Proj_No._091311_SSA_Warehouse.pdf | ||
| C.04.01_W912HN19B3005_Bid_Opening_Sign-In_Sheet_Proj_No._091311_SSA_Warehouse.pdf | ||
| 19B3005vol1.PDF | ||
| amd3.pdf | ||
| 19B3005vol1.PDF | ||
| amd2.pdf | ||
| W912HN19B3005_AMD2.PDF | ||
| amd1.pdf | ||
| 19B3005vol1.PDF | ||
| 19B3005_Site_Visit_Map.pdf | ||
| W912HN19B3005.PDF | ||
| 19B3005vol2.PDF | ||
| 19B3005vol1.PDF |
Show all 13
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EAVE HEIGHT
19' - 8"
FFE
0' - 0"
2" 12"
PURLINS BY PEMB MFR.
PREFINISHED
INSULATED STANDING SEAM
METAL ROOF PANELS
R32 MIN. (TYP)
BY PEMB MANUFACTURER
PREFINISHED METAL
FASCIA AND TRIM SYSTEM
BY PEMB MANUFACTURER
PREFINISHED METAL
DOWNSPOUT AND GUTTER
SYSTEM
BY PEMB MANUFACTURER
2" 6 5/8"
R-19 BATT INSULATION
VINYL FACED, HELD IN
PLACE WITH STRAPS
DUCTWORK / VENT
REFERENCE: MECH. SHEETS
LINER PANEL
10' - 0"
"Z" GIRTS (TYP)
BY PEMB MANUFACTURER
2" THICK PRE-FINISHED FACTORY
INSULATED METAL WALL PANELS (IMP)
(R-17 MIN.)
18 GAUGE METAL STRAP
24" HORIZONTAL O.C. (TYP)
CONCRETE SPLASH BLOCK
10' HT. P.F. METAL LINER PANEL W/
ANGLE CLOSURE, PAINT TO MATCH
STRUCTURAL STEEL FINISH BY
PEMB MANUFACTURER
EXT. METAL DOOR AND FRAME
REFERENCE PEMB MFR
DETAILS AT DOOR HEAD
REFERENCE: DOOR SCHEDULE
FLOOR FINISH REFER TO
FINISH SCHEDULE
FOOTER REFERENCE:
STRUCTURAL SHEETS
6" CHANNEL
3/4" PLYWOOD
EAVE HEIGHT
19' - 8"
FFE
0' - 0"
ADMIN. AREA
CEILING
9' - 0"
2" 12"
3 5/8" METAL STUD
"Z GIRT"
METAL CHANNEL TRACK
(TYP)
5/8" MOISTURE RESISTANT.
GYPSUM WALLBOARD
R-19 BATT INSULATION VINYL
FACED, HELD IN PLACE WITH
STRAPS
6"
4" PREFINISHED
INSULATED STANDING SEAM
METAL ROOF PANELS
R32 MIN. (TYP)
BY PEMB MANUFACTURER
ACOUSTICAL CEILING TILE
REFERENCE : REFLECTED CEILING
PLAN
LIGHT FIXTURE REFERENCE :
REFLECTED CEILING PLAN
A-501
A-501
6"
1/2" AIR GAP BETWEEN Z GIRTS
AND METAL STUDS
18 GAUGE METAL STRAP
24" HORIZONTAL O.C. (TYP)
3/4" PLYWOOD EAVE HEIGHT
19' - 8"
FFE
0' - 0"
2" 12"
PURLINS BY PEMB MFR., SPACED
2' - 0" O.C. TO SUPPPORT 3/4"
PLYWOOD DECKING
PREFINISHED
INSULATED STANDING SEAM
METAL ROOF PANELS
R32 MIN. (TYP)
BY PEMB MANUFACTURER
PREFINISHED METAL
FASCIA AND TRIM SYSTEM
BY PEMB MANUFACTURER
PREFINISHED METAL DOWNSPOUT
AND GUTTER SYSTEM BY PEMB
MANUFACTURER
STRUCTURAL FRAME BY PEMB
MANUFACTURER, FIELD PT.
CONCRETE FILLED STEEL PIPE
BOLLARD REFER TO SHEET S-502
FLOOR FINISH REFER TO
FINISH SCHEDULE
CONCRETE SPLASH BLOCK
LOUVER AND DUCTWORK
REFERENCE : MECH. SHEETS
R-19 BATT INSULATION VINYL
FACED, HELD IN PLACE WITH
STRAPS
M
IN
. 1 6'
0"
C
LE
AR
LINER PANEL
10' - 0"
10' HT. P.F. METAL LINER PANEL W/
ANGLE CLOSURE, PAINT TO MATCH
STRUCTURAL STEEL FINISH BY
PEMB MANUFACTURER
"Z" GIRTS (TYP)
BY PEMB MANUFACTURER
2" THICK PRE-FINISHED FACTORY
INSTALLED METAL WALL PANELS
(R-17 MIN.)
A-501
A-601
A-601
18 GAUGE METAL STRAP
24" HORIZONTAL O.C. (TYP)
3/4" PLYWOOD
1 2
US ARMY CORPS
OF ENGINEERS
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
FI
LE
N
AM
E:
A-302
W
AL
L
SE
C T I
O N
S
FO
R
T
ST
E W
AR
T, G
EO
R
G
IA
SA
VA
N N
AH
D
IS
TR
IC
T
W . O
G
LE
TH
O
R
PE
A V E
SA
VA
N
N
AH
, G A
ZA
PA
TA
IN
C O
R
PO
R
AT
ED
F
AI
R
VI
EW
R O
AD
S
U
IT
E 6A
C
H
AR
LO
TT
E, N
C
W
AS
W
AS
JP
/1
7/
W
2H N
-1 9-
B-
2-
-0
C
AT
EG
O R
Y C
O D
E
ISSUED FOR CONSTRUCTION
SU
PP
O R
T M
AI
N
T E N
AN
C
E W
AR
E H
O U
SE
S9 F A
-3
.D G
N
FY
1 9
, P N
1 3
3/4" = 1'-0"1
TRANSVERSE WALL SECTION AT
MECHANICAL ROOM
0 0.75 1.5
GRAPHIC SCALE 3/4"=1'-0"
0.375 3/4" = 1'-0"2
TRANSVERSE WALL SECTION
AT OFFICE
3/4" = 1'-0"3
TRANSVERSE WALL SECTION
AT WAREHOUSE
6" 1' 2'
R
EV
IS
ED
IN
A C
C O
R D
AN
C
E W
IT
H
A M
EN
D
M
EN
T
/2 2/
R
EV
IS
ED
IN
A
C C
O R
D
AN
C E
W
IT
H A
M
EN
D M
EN
T
/2
6/
A-302 WALL SECTIONS