3/4" THICK, 10' LENGTH, COPPER-CLAD

STEEL GROUND ROD (TYPICAL)UNDERGROUND, CONTINUOUS

#2/0 AWG COPPER GROUND

RING (TYPICAL)

#2/0 AWG COPPER ROOF

CONDUCTOR (TYPICAL)

#2/0 AWG COPPER DOWN

CONDUCTOR (TYPICAL)

12" BLUNT TIP, COPPER AIR

TERMINAL (TYPICAL)

NEW UTILITY

XFMR

TRANSFORMER PAD

TEST WELL

TEST WELL

EXOTHERMIC WELD

(TYPICAL)

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N

M

IC

H

IG

A

N A

V E

S U

IT

E

C H

IC

A

G O

IL

w w w .e xp fe d e ra l.

c o m p ro j.

n o :C

H I-

-A

C A

T E

G O

R Y

C O

D E

PLAN NORTH

EG101

G R

O U

N D

IN

G

P L A

N

H U

N T

E R

A R

M Y

A

IR

F

IE

L D

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B F

O S

S

J H

U E

R T

A

P Z

IN

N

I

G G

O R

S L

IN

E

S

E P

T E

M B

E R

W H

N -1

-B

-3

F

IL

E N

A M

E

ISSUED FOR CONSTRUCTION

F L E

X

IB

L E

E N

G

IN

E D

IA

G

N O

S T

IC

S

Y S

T E

M F

A C

IL

IT

Y

P N

H A

A F

A

M C

O M

-E T

F E

L E

C .r v t

E L E

C T

R

IC

A L

-4

-0

1/4" = 1'-0"1

LIGHTNING PROTECTION PLAN

SHEET NOTES:

1. ALL GROUNDING AND LIGHTNING PROTECTION

MATERIALS TO MEET CLASS I MATERIAL RATING FROM

NFPA 780. CONTRACTOR TO OBTAIN UL MASTER LABEL

CERTIFICATION FOR LIGHTNING PROTECTION SYSTEM

COMPONENTS AND INSTALLATION.

2. BURIED GROUND RODS SHALL BE 3/4" DIAMETER, 10'

LENGTH COPPER-CLAD STEEL GROUND ROD. RODS TO BE

BURIED AT LEAST 30" BELOW GRADE.

3. GROUND RODS TO BE SPACED AT LEAST THREE (3) ROD

LENGTHS APART.

4. GROUND AND BONDING CABLE SIZES ARE BASED ON

COPPER CONDUCTORS.

5. ALL BONDING CONNECTIONS TO GROUND RING AND

LIGHTNING PROTECTION SYSTEM MUST BE

EXOTHERMICALLY WELDED. NO MECHANICAL

CONNECTIONS ARE PERMITTED.

6. AIR TERMINALS TO BE BONDED TO THE TOP OF

DYNAMOMETER EXHAUST STACKS AND ENGINE EXHAUST

STACKS. AIR TERMINAL MATERIAL TO MATCH EXHAUST

STACKS.

7. GROUND RING TO BE PLACED AN AVERAGE DISTANCE OF

FIVE (5) FEET FROM BUILDING FOUNDATION.

8. COPPER AIR TERMINALS PLACED ON ROOF PERIMETER

SHALL BE LOCATED NO FURTHER THAN 12" FROM EDGE

OF ROOF.

9. ALL METAL BUILDING MATERIALS SHALL BE BONDED

TOGETHER SO ALL CONDUCTIVE MATERIALS ARE AT AN

EQUAL POTENTIAL. PROVIDE A GROUND AT TEST STANDS

TO GROUND TRAILERS. ALL METAL BOLLARDS SHOULD BE

BONDED TO GROUNDING SYSTEM.

0 2' 4' 8'

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

-1

-2

A

1 0.9 2 3 4

B

LDP;

LDP;

LDP;

LDP;

TELE;

LDP;

LDP;

LDP;

LDP;

LDP;

LDP XFMR

MDPLDP

ENGINE TESTING

BAY

CORRIDOR

RESTROOM

STORAGE

TELECOM

FIRE

PROTECTION

EQUIP.

MECH

ELEC. ROOM

OFFICE

1 LDP;

LDP;

LDP;

TELE;

TELE;

TELE;

LDP;

T

LDP;

VESTIBULE A

TELE

WP

WP

WP

TGB

MGB

G

REFER TO DETAIL 3 ON

SHEET E-504 FOR WIRE

OPENING DETAIL IN WALL

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N

M

IC

H

IG

A

N A

V E

S U

IT

E

C H

IC

A

G O

IL

w w w .e xp fe d e ra l.

c o m p ro j.

n o :C

H I-

-A

C A

T E

G O

R Y

C O

D E

PLAN NORTH

EP101

P O

W E

R P

L A

N

H U

N T

E R

A R

M Y

A

IR

F

IE

L D

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B F

O S

S

J H

U E

R T

A

P Z

IN

N

I

G G

O R

S L

IN

E

S

E P

T E

M B

E R

W H

N -1

-B

-3

F

IL

E N

A M

E

ISSUED FOR CONSTRUCTION

F L E

X

IB

L E

E N

G

IN

E D

IA

G

N O

S T

IC

S

Y S

T E

M F

A C

IL

IT

Y

P N

H A

A F

A

M C

O M

-E T

F E

L E

C .r v t

E L E

C T

R

IC

A L

-4

-0

1/4" = 1'-0"1

POWER PLAN

0 2' 4' 8'

KEYED NOTES:

CONTROL WIRING AND POWER CABLING TO BE PLACED IN 24"

WIDE, 6" DEEP, COPPER-FREE ALUMINUM CABLE TRAYS FROM

CONTROL CABIN TO ENGINES 1 AND 2 LOCATED IN ROOM 101

ENGINE TESTING BAY. POWER AND CONTROL CABLES FROM

CONTROL CABIN TO ENGINE TEST EQUIPMENT PROVIDED BY

CONTROL CABIN MANUFCATURER. CABLE TRAY TO BE

PROVIDED BY ELECTRICAL CONTRACTOR.

ALL ELECTRICAL EQUIPMENT LOCATED IN ENGINE TESTING BAY

SHALL BE RATED FOR CLASS 1, DIV 1, GROUP D HAZARDOUS

AREA.

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

-1

-2

OS

OS

OS

VS

VS

A

1 0.9 2 3 4

B

ENGINE TESTING

BAY

CORRIDOR

RESTROOM

STORAGE

TELECOM

FIRE

PROTECTION

EQUIP.

MECH

ELEC. ROOM

OFFICE

O S

12a F1

12a F1

10a F1

10a F1

5a F1

5a F1

10a F1

10a F1

12a F1

12a F1

12a F1

10a F1

10a F1

10a F1

3a F5

3a F5

2b F2

2e F5

2e F5

2e F5

2e F5

F7

F7

F7

F7

F7

F7

X2

F7

X1

12a F1

12a F1

10a F1

10a F1

5a F1

2a F4

3a F5

VESTIBULE A

12b F1

5a F1

X1

X1

X1

F3

F3 2

F3

2d F3

2d F3

2c F3

2c F3

4W

4W

4W

14'-6" AFF 14'-6" AFF 14'-6" AFF

a a a b a f e d c b b a a f g g g

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N

M

IC

H

IG

A

N A

V E

S U

IT

E

C H

IC

A

G O

IL

w w w .e xp fe d e ra l.

c o m p ro j.

n o :C

H I-

-A

C A

T E

G O

R Y

C O

D E

PLAN NORTH

EL101

L

IG

H T

IN

G

P L A

N

H U

N T

E R

A R

M Y

A

IR

F

IE

L D

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B F

O S

S

J H

U E

R T

A

P Z

IN

N

I

G G

O R

S L

IN

E

S

E P

T E

M B

E R

W H

N -1

-B

-3

F

IL

E N

A M

E

ISSUED FOR CONSTRUCTION

F L E

X

IB

L E

E N

G

IN

E D

IA

G

N O

S T

IC

S

Y S

T E

M F

A C

IL

IT

Y

P N

H A

A F

A

M C

O M

-E T

F E

L E

C .r v t

E L E

C T

R

IC

A L

-4

-0

1/4" = 1'-0"1

LIGHTING PLAN

SHEET NOTES:

1. LIGHT FIXTURES LOCATED IN THE ENGINE TESTING BAY

SHALL BE EXPLOSION-PROOF. ALL ELECTRICAL

EQUIPMENT LOCATED IN THE ENGINE TESTING BAY SHALL

BE RATED FOR CLASS I, DIVISION 1, GROUP D HAZARDOUS

AREA.

2. EXTERIOR LIGHTS SHALL BE CONTROLLED BY

PHOTOCELL. PHOTOCELL SHALL BE ON AT DUSK AND OFF

AT DAWN.

0 2' 4' 8'

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

-1

-2

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N

M

IC

H

IG

A

N A

V E

S U

IT

E

C H

IC

A

G O

IL

w w w .e xp fe d e ra l.

c o m p ro j.

n o :C

H I-

-A

C A

T E

G O

R Y

C O

D E

EL701

L

IG

H T

IN

G

S C

H E

D U

L E

A N

D D

E T

A

IL

S

H U

N T

E R

A R

M Y

A

IR

F

IE

L D

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B F

O S

S

J H

U E

R T

A

P Z

IN

N

I

G G

O R

S L

IN

E

S

E P

T E

M B

E R

W H

N -1

-B

-3

F

IL

E N

A M

E

ISSUED FOR CONSTRUCTION

F L E

X

IB

L E

E N

G

IN

E D

IA

G

N O

S T

IC

S

Y S

T E

M F

A C

IL

IT

Y

P N

H A

A F

A

M C

O M

-E T

F E

L E

C .r v t

E L E

C T

R

IC

A L

-4

-0

TAG FIXTURE DESCRIPTION MANUFACTURER AND CATALOG NO. LIGHT SOURCE DRIVER

MINIMUM

EFFICACY

LUMEN MAINTENANCE

(L70)

VOLTAGE VA MOUNTING REMARKS

F1 EXPLOSION-PROOF LED, ALUMINUM HOUSING, CLASS I, DIVISION 1, PHOENIX LXFB LED SERIES LED ARRAY, 8400 LM, 5000K, 80+

CRI (1) ELECTRONIC 95 50,000 HOURS 120 100 STRANDED WIRES

MOUNT AT +13'6" AFF UNO; INCLUDE 90 MINUTE

EMERGENCY BATTERY BACKUP WHERE SPECIFIEDGROUP D, 1' BY 4' NOMINAL SIZE OR APPROVED EQUAL

F2 LINEAR INDIRECT SPECIFICATION GRADE LED FIXTURE WITH STEEL LITHONIA 2BZL2 SERIES LED ARRAY, 2400 LM, 3500K, 82+

CRI (1) ELECTRONIC 85 60,000 HOURS 120 24 RECESSED GRID

CONSTRUCTION, 2' BY 2' NOMINAL SIZE OR APPROVED EQUAL

F3 LINEAR INDIRECT SPECIFICATION GRADE LED FIXTURE WITH STEEL LITHONIA 2BZL4 SERIES LED ARRAY, 4000 LM, 3500K, 82+

CRI (1) ELECTRONIC 85 60,000 HOURS 120 39 RECESSED GRID

CONSTRUCTION, 2' BY 4' NOMINAL SIZE OR APPROVED EQUAL

F4

SURFACE-MOUNTED WIDE DISTRIBUTION SPECIFICATION GRADE LED

LED ARRAY, 2000 LM, 3500K, 82+

CRI (1) ELECTRONIC 95 60,000 HOURS 120 20

SURFACE

OR

PENDANT

MOUNT AT +10'0" AFF IN MECH AND ELEC ROOM

FIXTURE WITH STEEL CONSTRUCTION, WHITE LITHONIA STL4 SERIES

DIE-CAST END CAPS, LINEAR FACETED REFRACTOR WITH OR APPROVED EQUAL

DIFFUSING FILM, 4' NOMINAL LENGTH

F5

SURFACE-MOUNTED WIDE DISTRIBUTION SPECIFICATION GRADE LED

LED ARRAY, 4000 LM, 3500K, 82+

CRI (1) ELECTRONIC 95 60,000 HOURS 120 20

SURFACE

OR

PENDANT

MOUNT AT +10'0" AFF IN FIRE EQUIP ROOM

FIXTURE WITH STEEL CONSTRUCTION, WHITE LITHONIA STL4 SERIES

DIE-CAST END CAPS, LINEAR FACETED REFRACTOR WITH OR APPROVED EQUAL

DIFFUSING FILM, 4' NOMINAL LENGTH

F7 EXTERIOR FULL CUT OFF WALL PACK, LED SOURCE, LITHONIA WST LED P2 SERIES 30 LED ARRAY, 4000K, 70+ CRI, 90+

LPW (1) ELECTRONIC 86 100,000 HOURS 120 71 WALL

FORWARD THROW DISTRIBUTION OR APPROVED EQUAL

X2

EXIT LIGHT UNIT WITH 6" HIGH RED LETTERING DISPLAYING "EXIT,"

LED ARRAY - - - 120 3 UNIVERSAL

PROVIDE BATTERY BACKUP FOR A MINIMUM OF 90

ILLUMINATED WITH LED SOURCES, INDUSTRIAL GRADE, LITHONIA LX SERIES MINUTES WITH SELF DIAGNOSTICS AND

STEEL HOUSING, SINGLE OR DOUBLE FACE AND OR APPROVED EQUAL NICKEL-CADMIUM BATTERIES

DIRECTIONAL ARROWS AS INDICATED

DISCLAIMER: THE USE OF MANUFACTURER'S NAMES AND PRODUCTS DO NOT PRECLUDE THE USE OF OTHER MANUFACTURER'S PRODUCTS OF APPROVED EQUAL AS LONG AS ALL REQUIREMENTS IN THE TECHNICAL SECTIONS ARE MET.

ROOM # ROOM NAME LIGHTING CONTROLS

100 CORRIDOR VACANCY/OCCUPANCY SENSOR

101 ENGINE TESTING BAY MANUAL

102 RESTROOM VACANCY/OCCUPANCY SENSOR

103 STORAGE MANUAL ON/VACANCY OFF

104 FIRE PROTECTION EQUIP. MANUAL

105 MECH MANUAL

106 ELEC. ROOM MANUAL

107 OFFICE MANUAL ON/VACANCY OFF

108 TELECOM MANUAL

110 VESTIBULE A VACANCY/OCCUPANCY SENSOR

--- BUILDING EXTERIOR PHOTOCELL (ON AT DUSK)

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

-1

-2

REFER TO ARCHITECTURAL ELEVATIONS FOR

MOUNTING HEIGHTS

X1

EXPLOSIONPROOF EXIT SIGN RATED FOR CLASS I, DIV 1, GROUP D

INCANDESCENT LAMP - - - 120 120 UNIVERSAL

PROVIDE BATTERY BACKUP FOR A MINIMUM OF 90

ILLUMINATED WITH TWO (2) INCANDESCENT LAMPS, INDUSTRIAL GRADE, CROUSE-HINDS EXL SERIES MINUTES WITH SELF DIAGNOSTICS AND

STEEL HOUSING, SINGLE OR DOUBLE FACE AND OR APPROVED EQUAL NICKEL-CADMIUM BATTERIES

DIRECTIONAL ARROWS AS INDICATED

20H5

L

GENTLY TAPERED AIR TERMINAL

ALUMINUM, 24" LENGTH, 0.5" DIAMETER

UNIVERSAL FLAT SURFACE

AIR TERMINAL BASE

MOUNTED HORIZONTALLY

ALUMINUM, CLASS I, 98,600

CIRCULAR MILS LIGHTNING

PROTECTION CONDUCTOR

CABLE FASTENER

TWIST-LOCK PHOTOCELL

SILICON TYPE WITH INTEGRAL MOV

SURGE SUPRESSION

1,800 VA, 120 VOLT RATED

TWIST-LOCK PHOTOCELL RECEPTACLE

ANSI C136.10 SEALED LOCKING

RECEPTACLE WITH MOUNTING

BRACKET

WEATHERPROOF JUNCTION BOX

MOUNTED ON BUILDING EXTERIOR

NONMETALLIC LIQUIDTIGHT FLEXIBLE

RACEWAY CONTAINING THREE LEAD

CONDUCTORS FROM PHOTOCELL

RECEPTACLE

MOUNTING BRACKET

WALL

CABLES

(TYPICAL)

FILL VOID

WITH CAVITY

MATERIAL

FIRE BLOCKS

AND NOISE

CANCELATION

MATERIAL

(TYPICAL)

2'-0"

CABLE

OPENING IN

WALL

NOTE:

VERIFY EXACT LOCATION OF WIRE OPENING AND HEIGHT

WITH CONTROL BOOTH (CONTROL BOOTH IS GFGI).

TO MATCH WALL

THICKNESS

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N

M

IC

H

IG

A

N A

V E

S U

IT

E

C H

IC

A

G O

IL

w w w .e xp fe d e ra l.

c o m p ro j.

n o :C

H I-

-A

C A

T E

G O

R Y

C O

D E

E-504

D E

T A

IL

S

H U

N T

E R

A R

M Y

A

IR

F

IE

L D

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

B F

O S

S

J H

U E

R T

A

P Z

IN

N

I

G G

O R

S L

IN

E

S

E P

T E

M B

E R

W H

N -1

-B

-3

F

IL

E N

A M

E

ISSUED FOR CONSTRUCTION

F L E

X

IB

L E

E N

G

IN

E D

IA

G

N O

S T

IC

S

Y S

T E

M F

A C

IL

IT

Y

P N

H A

A F

A

M C

O M

-E T

F E

L E

C .r v t

E L E

C T

R

IC

A L

NOT TO SCALE1

LIGHTNING PROTECTION HORIZONTAL AIR

TERMINAL DETAIL

NOT TO SCALE2

EXTERIOR PHOTOCELL MOUNTING DETAIL

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

-1

-2

12" = 1'-0"3

WIRE OPEING DETAIL

W

W

W

A

1 0.9 2 3 4

B

ENGINE TESTING

BAY

RESTROOM

STORAGE

TELECOM

FIRE

PROTECTION

EQUIP.

MECH

ELEC. ROOM

OFFICE

CORRIDOR

W T-401

US Army Corps of Engineers ®

SHEET ID

U S

A R

M Y

C O

R P

S O

F E

N G

IN

E

E R

S

D R

A W

N B

Y

D E

S

IG

N E

D B

Y

S U

B M

IT

T

E D

B Y

S

IZ

E

C H

E C

K E

D B

Y

A N

S I D

IS

S

U E

D A

T E

C O

N T

R A

C T

N O

S O

L

IC

IT

A

T

IO

N N

O

G

2 3 4 5 6 7 8 9 10

F

E

D

C

B

A

D A

T E

M A

R K

D E

S C

R

IP

T

IO

N

N

M

IC

H

IG

A

N A

V E

S U

IT

E

C H

IC

A

G O

IL

w w w .e xp fe d e ra l.

c o m p ro j.

n o :C

H I-

-A

C A

T E

G O

R Y

C O

D E

PLAN NORTH

T-101

S Y

S T

E M

S P

L A

N

H U

N T

E R

A R

M Y

A

IR

F

IE

L D

G

E O

R G

IA

S A

V A

N N

A H

D

IS

T R

IC

T

W

O

G L E

T H

O R

P E

A V

E

S A

V A

N N

A H

G

A

J E

H L E

R S

J H

U E

R T

A

P Z

IN

N

I

B B

R E

U N

IG

S

E P

T E

M B

E R

W H

N -1

-B

-3

F

IL

E N

A M

E

ISSUED FOR CONSTRUCTION

F L E

X

IB

L E

E N

G

IN

E D

IA

G

N O

S T

IC

S

Y S

T E

M F

A C

IL

IT

Y

P N

H A

A F

A

M C

O M

-E T

F T

E L E

.r v t

T E

L E

C O

M M

U N

IC

A

T

IO

N S

-4

-0

1/4" = 1'-0"1

FIRST FLOOR TELECOM PLAN

0 2' 4' 8'

R

E V

IS

E

D I N

A C

C O

R D

A N

C E

W

IT

H A

M E

N D

M E

N T

-1

-2

1. SEE SHEET T-001 FOR LEGEND, DEFAULT OUTLET ELEVATIONS, GENERAL

NOTES, AND ABBREVIATIONS

2. SEE SHEET E-001 FOR ADDITIONAL GENERAL NOTES, AND ABBREVIATIONS.

SHEET NOTES

EG101 GROUNDING PLAN
EP101 POWER PLAN
EL101 LIGHTING PLAN
EL701 LIGHTING SCHEDULE AND DETAILS
E-504 DETAILS
T-101 TELECOMMUNICATIONS SYSTEMS PLAN