X-Ray Inspection System Specification_10 SEP 2024.docx
DOCX document 23 KB Posted
- Attached to
- X-Ray Inspection System
- Solicitation number
- W912GY24Q0028
About this file
This document is a specification for an X-Ray Inspection System required by the Department of the Army Materiel Command Contracting Command Detroit Arsenal. The key details are:
The X-Ray Inspection System must have a tunnel size that can scan objects up to 59 inches wide by 70.9 inches high, with a conveyor belt capable of handling at least 2,646 lbs and moving in both forward and reverse directions. The system must have an image recall function to display at least 10 previously scanned objects, and controls to stop, move forward, and move backward the conveyor belt. Technically, the system must provide at least 28 mm of steel penetration, 38 AWG wire resolution, 100% duty cycle, less than 0.1 mR per hour dose per exam, and less than 0.5 mR per hour radiation leakage.
The related federal contract opportunity, solicitation number W912GY24Q0028, is a pre-solicitation for a firm-fixed price contract to provide one X-Ray Inspection System. It will be a small business set-aside using Simplified Acquisition Procedures, with a NAICS code of 334519 and a 600-employee size standard. The solicitation is anticipated to be released on 10/01/2024 by the Department of the Army Materiel Command Contracting Command Detroit Arsenal.
View the file
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
X-Ray Inspection System Desired Specifications
General
· Tunnel Size: Must be able to scan objects up to 59 inches x 70.9 inches (W x H)
· Conveyer: Pulling weight must be no less than 1200 kg (2,646 lbs) and belt movement must be bidirectional (forward and reverse)
· Operating System: Must be able to connect to external monitors via HDMI cable. Must contain an image recall function that can show at least 10 previously scanned objects. Must include controls for belt movement with options to stop, move forward and backward. Comment by Worrell, Tracy E CIV USARMY ACC (USA): Do we want to address the operator control panel and ability to at a minimum move objects forward, backward and stop? Comment by Worrell, Tracy E CIV USARMY ACC (USA): The Autoclear specs call out a specific quantity for Autoimage recall, maybe we can use that as a minimum standard Autoimage recall must be 10 previously scanned images or more or something like that
· System Power: 220 VAC +/- 10%
Technical
· Steel Penetration: Must be at least 28 mm
· Wire Resolution: Must be at least 38 AWG
X-Ray Generator
· Duty Cycle: 100%
· Dose per Exam: Must be less than 0.1 mR per hour
· Radiation Leakage: Must be less than 0.5 mR per hour