This conceptual site map and solicitation are for a design-build project to construct a new maternity ward at an existing health clinic in Seronga, Botswana. The project includes demolition or relocation of existing small structures as needed, construction of the new maternity ward building, a septic tank, emergency generator pad, exterior hose spigots and fencing. The existing clinic must remain operational during construction. Dimensions are in meters and must be field verified. The Army Corps of Engineers Europe District will award a firm-fixed price contract using a best value tradeoff method for an estimated $250,000 to $500,000 construction value. Proposals are due under full and open competition to the Department of the Army European Command in US dollars.

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

D

C

I

B

A

I f

3 4 5

GENERAL NOTES:

1. EXISTING CONDITIONS SHOWN ARE THE COMBINED

RESULT OF AERIAL IMAGERY, GIS, AND SITE VISIT

PHOTOS. CONTRACTOR MUST FIELD VERIFY ALL

EXISTING CONDITIONS.

2.

3.

4.

5.

6.

7.

8.

ANY PROVIDED DIMENSIONS ARE IN METERS UNLESS

OTHERWISE STATED AND ARE FOR INFORMATION ONLY

AND MUST BE VERIFIED IN THE FIELD BY THE

CONTRACTOR.

THE EXISTING CLINIC MUST REMAIN IN FULL

OPERATION DURING THE CONSTRUCTION OF THE NEW

BUILDING.

ANY MOVEMENT OR DEMOLITION OF EXISITNG

BUILDINGS MUST BE APPROVED BY SITE OWNERS.

PROVIDE MINIMUM 1 METER WIDE CONCRETE APRON

BUILDING APRON AROUND THE ENTIRE BUILDING.

THE EXACT POSITION OF THE EXISTING SEPTIC TANK

IS NOT KNOWN.

EXISTING MUNICIPAL WATER HOOKUP IS LOCATED ON

THE WEST SIDE OF THE SITE. EXACT LOCATION MUST

BE DETERMINED IN THE FIELD.

THE PROPOSED FOOTPRINT CONTAINS SMALL SHED

STRUCTURES. REMOVAUMOVEMENT OF THESE

STRUCTURES MUST BE COORDINATED WITH THE SITE

OWNERS.

KEYNOTE

EXISTING CLINIC

PROPOSED NEW MATERNITY WARD CLINIC BUILDING

PROPOSED SEPTIC TANK LOCATION

PROPOSED EMERGENCY GENERATOR PAD

EXISTING PROPERTY LINE / PROPOSED FENCE

EXISTING AGGREGATE ACCESS ROAD

EXISTING CLINIC SEPTIC TANK

EXISTING POWER POLE FOR HOOKUP

PROPOSED EXTERIOR HOSE SPIGOT

US Army Corps of Engineers

Europe District i i i

19 i9 !

z w

:c

::, z "- "W

3:

�b

Z ID

u .; u :c z

"'-"' ..,w

:c "' z 0 "' w

<.:) z c2 w w z i3 z w z ...J a.

w vi ...J

a. w u z u

S h ee t re f erence number:

i

I MT2

+------------------------------------------------------c_ o.,..n_c_e_p_ t_u_a_l _L_a_y_o_u _t _o_n _ lY ________ s_ h e e t f -+-

File details come from the government source that posted it. Updated .