Cover Installation Status Report (ISR) - Infrastructure
| 15 - BULK FUEL FACILITIES | ||
| PROPONENTS: | ||
| Mission Components: | ||
| REVISION DATE: | 10/5/17 | Deputy Chief of Staff, G-4, DALO-SM (703) 767-0649/DSN 427-0649, (Army Materiel Command, AMCBT-F (703) 806-8724 /DSN 806-8724) |
| FOR USE WITH THE FY 2018 ISR-I DATA COLLECTION | ||
| Quality Components: | ||
| Assistant Chief of Staff for Installation Management, DAIM-ODR (571)-256-8157/DSN (312) 260 8157 |
| CATCD | TITLE | Description |
| 12440 | MARINE FUEL STORAGE TANK, UNDERGROUND | (Business Rule Rated) Underground storage tanks used for operational fueling of small boats and craft. See the 411-series, Bulk Liquid Fuel Storage, for bulk fuel storage and 12441, Marine Fuel Storage Tank, Above Ground, for operational storage tanks above ground. |
| 12441 | MARINE FUEL STORAGE TANK, ABOVE GROUND | (Business Rule Rated) Above ground storage tanks used for operational fueling of small boats and craft. See the 411-series, Bulk Liquid Fuel Storage, for bulk fuel storage and 12440, Marine Fuel Storage Tank, Underground, for operational storage tanks underground. |
| 12473 | KEROSENE STORAGE TANK, ABOVE GROUND | (Business Rule Rated) Aboveground storage tanks of kerosene fuel at any of several locations: dispensing stations, connected to heating systems, or electrical power plants. See 12472, Kerosene Storage Tank, Underground, for operational storage tanks underground. |
| 12482 | LIQUID PROPANE GAS STORAGE TANK, UNDERGROUND | (Business Rule Rated) Underground storage tanks for the immediate backup storage and dispensing of liquid propane gas. See the 411-series, Bulk Liquid Fuel Storage, for bulk fuel storage and 12483, Liquid Propane Gas Storage Tank, Above Ground, for operational storage tanks above ground. |
| 12483 | LIQUID PROPANE GAS STORAGE TANK, ABOVE GROUND | (Business Rule Rated) Aboveground storage tanks for the immediate backup storage and dispensing of liquid propane gas. See the 411-series, Bulk Liquid Fuel Storage, for bulk fuel storage and 12482, Liquid Propane Gas Storage Tank, Underground, for operational storage tanks underground. |
| 12510 | POL PIPELINE, ABOVE GROUND | (Business Rule Rated) Aboveground pipelines that carry petroleum products such as fuel and oil; they may be welded, coupled, or hose line construction. There are assault, tactical, and logistical pipe categories; however, the logistical category is the type normally associated with permanently installed real property. This CATCD is used for only major transmission or distribution systems. All equipment that is an integral part of the pipeline system should be carried in an equipment table for the pipeline. Any facilities associated with the pipeline system should be carried as 14165, Fueling/POL/Wash Support Building or 14164, Fueling/POL/Wash Support Facility. Aboveground POL pipelines are generally made of black carbon steel, but aluminum and black reinforced plastic pipe are also used. |
| 12520 | POL PIPELINE, UNDERGROUND | (Business Rule Rated) Underground pipelines that carry petroleum products such as fuel and oil; they may be welded, coupled, or hose line construction. There are assault, tactical, and logistical pipe categories; however, the logistical category is the type normally associated with permanently installed real property. This CATCD is used for only major transmission or distribution systems. All equipment that is an integral part of the pipeline system should be carried in an equipment table for the pipeline. Any facilities associated with the pipeline system should be carried as 14165, Fueling/POL/Wash Support Building or 14164, Fueling/POL/Wash Support Facility. |
| 12521 | POL PIPING SYSTEM, WITHIN A SITE | (Business Rule Rated) TBD |
| 12610 | HEATING FUEL OIL DISPENSING FACILITY | (Business Rule Rated) A structure to dispense heating fuel oil. This CATCD includes only the fuel dispensing system and not the storage tanks. Heating fuel oil storage is in the 124-series, Operational Fuel Storage. One OL is the equivalent of one dispensing nozzle. |
| 12630 | TANK TRUCK LOAD/UNLOAD FACILITY | (Business Rule Rated) A structure to dispense fuel from bulk storage tanks into fuel delivery trucks or vice versa. It is also known as a truck fill stand. Loading is generally a top-loading type that consists of an elevated structural steel platform with stairway and a telescoping loading arm assembly. This CATCD includes only the fuel loading and/or unloading system and not the storage tanks. One OL is the equivalent of one dispensing nozzle. |
| 12640 | TANK CAR LOAD/UNLOAD FACILITY | (Business Rule Rated) A structure to dispense fuel from bulk fuel storage tanks into railroad tank cars or vice versa. Loading is generally an open grate steel platform located alongside and about 10 feet above the rail spur. A counterbalanced tank car loading arm assembly and drop walkway are located at each loading outlet. Unloading generally consists of one or more suction-type (gravity) hose lines from riser pipes. This CATCD includes only the fuel loading and/or unloading system and not the storage tanks. One OL is the equivalent of one dispensing nozzle. |
| 12650 | BARGE LOAD/UNLOAD FACILITY | (Business Rule Rated) A structure to dispense fuel from bulk storage tanks into fuel barges or vice versa. Loading and/or unloading generally consists of fuel outlets, pumps, and a pipeline cross connection between the product withdrawal and receiving lines from a dock or pier. This CATCD includes only the fuel loading/unloading system and not the storage tanks. One OL is the equivalent of one dispensing nozzle. |
| 12660 | TANKER LOAD/UNLOAD FACILITY | (Business Rule Rated) A structure to dispense fuel from bulk storage tanks into fuel tankers or vice versa. It generally consists of fuel outlets, pumps, and a pipeline cross connection between the product withdrawal and receiving lines from a dock or pier. This CATCD includes only the fuel loading and/or unloading system and not the storage tanks. One OL is the equivalent of one dispensing nozzle. |
| 12670 | DRUM LOADING FACILITY | (Business Rule Rated) A structure used to load drums with fuel, propellants, or lubricants. One OL is the equivalent of one dispensing nozzle. |
| 41110 | MARINE FUEL STORAGE, BULK, ABOVE GROUND | Tanks for bulk storage of liquid marine fuels. These tanks are aboveground types used for storage of fuel prior to its transfer to end-use dispensing stations. For underground storage, use 41111, Marine Fuel Storage, Bulk, Underground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41111 | MARINE FUEL STORAGE, BULK, UNDERGROUND | Tanks for the bulk storage of liquid marine fuels. These tanks are located underground. For above ground storage, use 41110, Marine Fuel Storage, Bulk Above Ground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41120 | AVIATION GAS STORAGE, ABOVE GROUND, BULK | Tanks for bulk storage of nonjet aircraft fuels. These tanks are the aboveground types used for storage of fuel prior to its transfer to end-use dispensing stations. For underground storage, use 41122, Aviation Gas Storage, Underground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41121 | JET FUEL STORAGE, ABOVE GROUND, BULK | Tanks for bulk storage of jet aircraft fuels. These tanks are aboveground types used for storage of fuel prior to its transfer to end-use dispensing stations. For underground storage, use 41123, Jet Fuel Storage, Underground, Bulk. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41122 | AVIATION GAS STORAGE, UNDERGROUND, BULK | Tanks for the bulk storage of nonjet aircraft fuels. These tanks are located underground. For above ground storage, use 41120, Aviation Gas Storage, Above Ground, Bulk. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41123 | JET FUEL STORAGE, UNDERGROUND, BULK | Tanks for the bulk storage of jet aircraft fuels. These tanks are located underground. For aboveground storage, use 41121, Jet Fuel Storage, Above Ground, Bulk. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41124 | LIQUID FUEL STORAGE, LARGE BULK (LARGER THAN 100,000 BARRELS) | (Business Rule Rated) TBD |
| 41130 | DIESEL OIL/JP8 STORAGE, ABOVE GROUND, BULK | Tanks for bulk storage of diesel fuels and JP8. These tanks are aboveground types used for storage of fuel prior to its transfer to end-use dispensing stations. For underground storage, use 41131, Diesel Oil/JP8 Storage, Underground, Bulk. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41131 | DIESEL OIL/JP8 STORAGE, UNDERGROUND, BULK | Tanks for the bulk storage of diesel fuels and JP8. These tanks are located underground. For above ground storage, use 41130, Diesel Oil/JP8 Storage, Above Ground, Bulk. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41132 | CUT-AND-COVER BULK LIQUID FUEL STORAGE | (Business Rule Rated) Cut and cover tank means a tank that is constructed with steel or reinforced concrete that is surrounded by soil above the natural surface of the ground. |
| 41140 | GASOLINE STORAGE, ABOVE GROUND, BULK | Tanks for bulk storage of gasoline fuels. These tanks are aboveground types used for storage of fuel prior to its transfer to end-use dispensing stations. For underground storage, use 41141, Gasoline Storage, Underground, Bulk. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41141 | GASOLINE STORAGE, UNDERGROUND, BULK | Tanks for the bulk storage of gasoline fuels. These tanks are located underground. For aboveground storage, use 41140, Gasoline Storage, Above Ground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41150 | LIQUEFIED GAS STORAGE, ABOVE GROUND, BULK | Tanks for bulk storage of liquefied petroleum gas fuels. These tanks are aboveground types used for storage of fuel prior to its transfer to end-use dispensing stations. For underground storage, use 41151, Liquefied Gas Storage, Underground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41151 | LIQUEFIED GAS STORAGE, UNDERGROUND, BULK | (Business Rule Rated) Tanks for the bulk storage of liquified gas fuels. These tanks are located underground. For aboveground storage, use 41150, Liquefied Gas Storage, Above Ground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41160 | LIQUID PROPELLANT STORAGE, ABOVE GROUND, BULK | Tanks for bulk storage of liquid propellant. These tanks are aboveground types used for storage of propellant prior to its transfer to end-use dispensing stations. For underground storage, use 41161, Liquid Propellant Storage, Underground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41161 | LIQUID PROPELLANT STORAGE, UNDERGROUND, BULK | Tanks for the bulk storage of liquid propellants. These tanks are located underground. For aboveground storage, use 41160, Liquid Propellant Storage, Above Ground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41170 | LUBRICANT STORAGE | Tanks for bulk storage of lubricants. |
| 41180 | FUEL OIL STORAGE, ABOVE GROUND, BULK | Tanks for bulk storage of heating fuel oil. These tanks are aboveground types used for storage of fuel prior to its transfer to end-use dispensing stations. For underground storage, use 41181, Fuel Oil Storage, Underground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
| 41181 | FUEL OIL STORAGE, UNDERGROUND, BULK | Tanks for the bulk storage of heating fuel oil. These tanks are located underground. For aboveground storage, use 41180, Fuel Oil Storage, Above Ground. See the 124-series, Operational Fuel Storage, for operational fuel storage. |
&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"15 - BULK FUEL FACILITIES
Instructions
| Installation Status Report (ISR) - Infrastructure |
| ISR-I FACILITY INSPECTION INSTRUCTIONS. |
| GENERAL INSTRUCTIONS |
| 1. Most Workbooks will have Facility Category Codes (CATCDs) rated by inspection and by Business rule and this is new for FY17. ISR-I will display the business rule rated CATCDs on a separate page along with the system generated ratings. Reporting locations are required to review the system rating, however, the concur checkmark is already in place. If an overwrite is required please see details published in the ISR-Infrastructure Implementing Instructions. |
| 2. Component Shading: When a Facility Category Code (CATCD) is selected on the Worksheet Tab the components recommended for use will be shaded on both the Worksheet and on the WB tabs. This is only a recommendation and any component not being shaded may also be used. |
| 3. Design Use and Current Use: The first component in each workbook ask if the CATCD in the workbook matches the actual use of the facility. Green is Yes, and Red is No. This refers to the design use and the current use and lowers the mission score when the two are not the same. DO NOT Mark Amber in ISR Web. |
| 4. Workbook Cover: CATCD Descriptions provide help for the inspector. When the description of the CATCD does not match the use of the facility, then component 1 should be marked Red. The new logo on the FY17 Workbooks visually distinguishes them from previous years. |
| 5. The WB_Print tab allows printing of the WB tab with spaces for pencil input. This eliminates the need to download a PDF version and is no longer available. |
| 6. The Component Calculation Sheet and the Worksheet Supplement are tabs on the Excel Workbook. |
| • These two sheets will be phased out beginning in FY18. |
| 7. Select the appropriate facility inspection worksheet and standards rating booklet to evaluate your facility. |
| • The appropriate booklet number is identified at the top of the worksheet downloaded from ISR Web. |
| • Only use worksheets from ISR Web. These worksheets have the correct installation and facility information printed at the top of the page. |
| • Verify the facility number on the worksheet matches the number on the facility you are inspecting. |
| • Confirm that the Facility Category Code (CATCD) description on the facility inspection worksheet matches the space you will be rating in the facility. The first rating in each Inspection Standards Workbook has a yes (Green)or no (Red) question to be answered about this. |
| • Some facilities consist of space from several CATCDs, each requires a separate facility inspection worksheet and associated rating booklet. |
| 8. Fill in the Inspector name, email, phone number, and date completed in the space provided on the paper worksheet or in the excel workbook, worksheet tab. Enter the UIC if known and the site code can be the installation name. |
| 9. Grade each element of a component rating section by reading the condition description for each element, and determining the BEST FIT as it applies to your facility. |
| • Each component rating section has elements that you will evaluate as GREEN, AMBER, or RED. The points totaled for the rated elements will help in determining the rating of the component. |
| • In those cases when an element does not exist and does not apply to a facility rate it NA |
| 10. For every component that is rated RED for either Mission Functional Capability or Quality, write a brief explanation in the space provided on the facility inspection worksheet. Continue on the back of the worksheet or on a separate page if needed. If using the excel workbook all comments made on the WB tab carry over to the Worksheet tab automatically. General comments may also be made on the Worksheet tab. |
| • For each RED component rating, consider submitting a work order to correct the deficiency. |
| • Optional: Write a brief comment concerning any facility location issues, such as location of the facility on the installation, proximity to related facilities, and appropriate vehicle access. Continue on the reverse of the inspection worksheet if needed. |
| • Optional: Write a brief comment concerning any environmental, health, safety, and historic preservation issues. Continue on the reverse of the inspection worksheet if needed. |
| 11. Each inspector must review the completed inspection worksheet and sign on the appropriate page. The person signing the workbook is the one having the most knowledge of the inspection performed and most likely to be able to answer questions about the inspection. |
| SPECIAL INSTRUCTIONS APPLICABLE TO THIS WORKBOOK ONLY: |
| (All) Rated by Builder. When the facility is scheduled to be inspected by the Builder SMS application the ISR Quality inspeciton is no longer required. When this box is checked the Quality ratings will become gray and NA appear on the Worksheet tab. |
| (ALL) Army Standard Design Criteria. The WB tab has a checkbox at the top left for optional use if construction meets Army Standard Design Criteria. When checked all Mission Functional Elements become green. Other ratings that will override this selection are: Component ratings of NA or Needed. |
&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"15 - BULK FUEL FACILITIES
Download worksheets from ISR data input module
Make list of Workbooks needed
Download Workbooks from ISR Web. The excel file has all materials
After training conduct the inspection
Record results in on the Excel WB tab
The Component Calculation Sheet and Worksheet Supplement are required only if not using the WB tab.
Enter component rating and comments in ISR Web
Alerts Component Description Alerts
&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"15 - BULK FUEL FACILITIES
WB
| WB: | 15 | Meets Army Standard Design Criteria | ||
| Inspected By Builder | FALSE |
| # | Component | Rating Area | Element | Green | Amber | Red | Order | Points | Selection | Comments | Type | Insp Num | Description | Rating Area | For Alt Rows | Compare Cell above for N/A or Needed | Compare Cell below for N/A or Needed | Value | Other Column | Green | Amber | Red | Concatenate | Red Comms1 | Red Comms | Red Comms | Row | 4L above | 4L Below | 4L Total | Capacity Above | Capacity Below | Capacity Total | N/A | Green Points | Amber Points | Red Points | Cmt # |
| 1 | CATCD Agreement | F | Facility Use | The FCC (CATCD) used for this inspection matches the current use of the facility. | NA | The FCC (CATCD) used for this inspection does not match the current use of the facility. | 1 | 10 | Common Components | 1 | CATCD Agreement | F | 1 | 1F | ||||||||||||||||||||||||
| 2 | Site | F | External Factors | In the estimation of the evaluator the site meets the following criteria: |
- Location is convenient and appropriate.
- Facility function is not limited by the site.
- Resrictions are not present:
-- - Visibility -- - Access -- - Light / Noise
| -- - Safety concerns | A. One criteria applicable to the facility being inspected is not fully acceptable. | A. One or more criteria applicable to the facility being inspected is significantly deficient in the opinion of the evaluator. | 0 | 10 | Common Components | 2 | Site | F | 2 | 2F | |||||||||
| 3 | Antiterrorism | F | Risk Assessment | A. Facility has a current risk assessment or is included in an installation risk assessment. | NA | A. Facility does not have a current risk assessment and is not included in an installation risk assessment. | 0 | 12 | Common Components | 3 | Antiterrorism | F | 3 | 3F | |||||
| 3 | Antiterrorism | F | Recommendations from Risk Assessment | A. All recommendations for the risk assessment have been accomplished. | A. An action plan from the risk assessment created. | ||||||||||||||
| B. Less than 50% of risk assessment recommendations enacted and mitigation in place for the remainder. | A. No Action Plan for risk assessment findings. | ||||||||||||||||||
| B. Less than 50% of risk assessment recommendations enacted and mitigation not in place for the remainder. | 1 | 10 | Common Components | 3 | Antiterrorism | F | 3 | 3F | |||||||||||
| 3 | Antiterrorism | F | Uniform Facilities Criteria (UFC) 4-010-01, DoD Minimum Antiterrorism Standards for Buildings | A. Facility is in compliance with UFC 4-010-01 standards for new facilities, including construction and standoff for parking. | A. Facility is in compliance with UFC 4-010-01 Standards for existing facilities, including construction and standoff for parking. | A. Facility is not in compliance with UFC 4-010-01 Standards. | 2 | 10 | Common Components | 3 | Antiterrorism | F | 3 | 3F | |||||
| 3 | Antiterrorism | F | Facility Antiterrorism Exercises | A. Facility has executed all Antiterrorism Measures during the preceding 12 months. |
B. The Facility conducted an Antiterrorism Exercise that included some AT Measures within the preceding 12 months.
| C. After action reports are on file with the installation or command antiterrorism officer. | A. The Facility has exercised 50% of Antiterrorism Measures during the preceding 12 months. | |||||||||||||||||
| B. The Facility conducted an Antiterrorism exercise that included some AT Measures within the preceding 12 months. | A. The Facility has not exercised Antiterrorism Measures during the preceding 12 months. | |||||||||||||||||
| B. The Facility has not conducted an Antiterrorism Exercise during the preceding 12 months. | 3 | 8 | Common Components | 3 | Antiterrorism | F | 3 | 3F | ||||||||||
| 4 | Accessibility | F | Grounds | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 0 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Building Exterior | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 1 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Lobby | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 2 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Corridors | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 3 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Conveyance -Stairs, Elevator, Escalator | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 4 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Administrative Areas | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 5 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Latrine | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 6 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Fire Protection | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 7 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 5 | Receiving And Issue Operations | F | Capability | A. Excellent – The size, capacity, or amount of this component meets at least 90% of functional requirements. | A. Marginal – The size, capacity, or amount of this component meets at least 60% of functional requirements. | A. Inadequate – The size, capacity, or amount of this component does not meet at least 60% of functional requirements. | 1 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Containment Berm | A. Containment berm encompasses entire Receiving/Issue area. | A. A containment berm exists, but does not enclose the entire Receiving/Issue Area. | A. No spill containment control is installed in facility. | 5 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Top Loading / Unloading Facility | A. Loading arm, platform, and stairs are installed in facility. | NA | A. Loading arm, platform, or stairs are NOT installed in facility. | 6 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Bottom Loading / Unloading Facility | A. Bottom-loading equipment and high flow gravity & ramp loading & off-loading installed. | ||||||||||||||
| B. Bottom-loading equipment and high flow gravity & ramp loading & off-loading equipment meets all facility mission(s) requirements. | A. Bottom-loading equipment and high flow gravity & ramp loading & off-loading equipment meets facility mission(s) requirements. | A. Bottom-loading equipment and high flow gravity & ramp loading & off-loading not installed. | ||||||||||||||||
| B. Bottom-loading equipment and high flow gravity & ramp loading & off-loading equipment do not meet facility mission(s) requirements. | 7 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||||||||
| 5 | Receiving And Issue Operations | F | Off-Loading Accommodations | A. Facility accommodates off-loading and issue of bulk POL products. | A. Facility does not accommodate off-loading operations without modifications. | A. Facility cannot accommodate all facility off-loading mission(s) under any circumstances. | 8 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Grounding Rod | A. Grounding rod available for tank trucks. | NA | A. Grounding rod NOT available for tank trucks. | 103 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Weighing Equipment | A. Calibrated meter or loading weigh station available. | A. Meter/weigh station equipment not calibrated or accurate. | |||||||||||||
| B. Calibration has expired. | A. Facility is NOT equipped with meter/weigh station. | 104 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | |||||||||
| 5 | Receiving And Issue Operations | F | Manifold | A. Manifolding available to meet all facility fuel transferring missions. | A. Manifolding available to meet all facility transferring missions. | A. Manifolding NOT available to meet all facility transferring missions. | 105 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Off-Loading Area | A. Off-loading area composed of concrete. | NA | A. Off-loading area is NOT composed of concrete. | 107 | 6 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Vehicle Access Road | A. Road is circular or wide enough to permit forward movement of all tank trucks. | A. Road requires widening to permit forward movement of all tank trucks. | A. Road is unpaved. | 108 | 6 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Occupied Building Proximity | A. Occupied buildings at least 50 feet from facility. | NA | A. Occupied building(s) less than 50 feet from facility. | 203 | 6 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | Q | Equipment Hose Lines | A. Equipment hose lines and fittings are fully functional and show no signs of damage or deterioration. | A. Equipment hose lines and fittings are fully functional, but show signs of wear, deterioration, or damage. | A. Equipment hose lines and/or fittings leak. | 4 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 5 | Receiving And Issue Operations | Q | Top Loading / Unloading Facility | A. Loading arm, platform, and stairs are fully functional and show no signs of deterioration or damage. | A. Loading arm, platform, and/or stairs are fully functional, but show signs of deterioration or damage. | A. Loading arm, platform, and/or stairs are deteriorated or damaged to the extent of jeopardizing operations and/or safety. | 6 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 5 | Receiving And Issue Operations | Q | Bottom Loading / Unloading Facility | A. Bottom-loading equipment and high flow gravity & ramp loading & off-loading equipment meets all facility mission(s) requirements and shows no signs of damage or deterioration. | NA | A. Bottom-loading equipment and high flow gravity & ramp loading & off-loading equipment meets facility mission(s) requirements, but shows signs of damage or deterioration. | 7 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 5 | Receiving And Issue Operations | Q | Grounding Rod | A. Grounding rod shows no signs of deterioration or damage. | A. Grounding rod functional, but shows signs of deterioration or damage. | A. Grounding rod not functional. | 103 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 5 | Receiving And Issue Operations | Q | Weighing Equipment | A. Meter/weigh station equipment fully functional and shows no signs of deterioration or damage. | A. Meter/weigh station equipment functional but shows signs of deterioration or damage. | A. Meter/weigh station equipment does not function. | 104 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 5 | Receiving And Issue Operations | Q | Manifold | A. Manifolding equipment functional with no signs of deterioration or damage. | A. Manifolding equipment functional but shows signs of deterioration or damage. | A. Manifolding equipment deteriorated and/or damaged and not functional. | 105 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 5 | Receiving And Issue Operations | Q | Off-Loading Area | A. Off-loading area is level with no large cracks or holes. | A. Off-loading area has cracks, holes, or deflections on no more than 25% of the surface. | A. Off-loading area has cracks, holes, or deflections on more than 25% of the surface. | 107 | 6 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 5 | Receiving And Issue Operations | Q | Vehicle Access Road | A. Road has no large cracks or holes. | A. Road has large holes, cracks, or deflections on no more than 25% of the surface. | A. Road has large holes, cracks, or deflections on more than 25% of the surface. | 108 | 6 | Facility Specific Components | 5 | Receiving And Issue Operations | Q | 5 | 5Q | ||||
| 6 | Storage Operations | F | Spill Container | A. Facility sufficiently supplied with spill containers to meet all facility mission(s) requirements. | A. Spill containers are installed but do not have the capacity to meet all facility mission(s) requirements. | A. Spill containers are not installed. | 4 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||||
| 6 | Storage Operations | F | Fencing | A. Facility completely surrounded by security fencing. | A. Facility completely surrounded by security fencing. | A. Facility NOT surrounded by security fencing. | 5 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||||
| 6 | Storage Operations | F | Gauging Equipment | A. Proper gauging equipment available to detect fuel leaks and/or water accumulation. | A. Proper gauging equipment available to detect fuel leaks and/or water accumulation. | A. Proper gauging equipment is NOT available to detect fuel leaks and/or water accumulation. | 6 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||||
| 6 | Storage Operations | F | Utility Wires | A. Utility wires are not located directly overhead of facility. | A. Facility has waivers for utility wires directly overhead. | A. Facility has overhead wires with no waiver. | 7 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||||
| 6 | Storage Operations | F | Labeling | A. Tanks are properly and completely marked with product identification. |
B. Pipelines are properly and completely marked with product identification.
C. Manifold system on tank fully and properly labeled.
D. Labels are easily readable (ex. not faded, not torn, etc.). A. Tanks are NOT completely marked with product identification.
B. Pipelines are NOT completely marked with product identification.
C. Manifold system on tank is NOT completely labeled.
D. Labels are not easily read (faded, torn, etc.). A. Tanks are NOT marked with product identification.
B. Pipelines are NOT marked with product identification.
C. Manifold system on tank is NOT labeled.
| D. Facilities are NOT labeled. | 103 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||
| 6 | Storage Operations | F | Aboveground Storage Tanks | A. Tanks have functional bottom drain (water draw off) system. |
B. High/Low level alarms and leak detection system.
C. API 653 inspection has been previously performed and is current with copy of the report available, and the next inspection is due within the next 10 years.
D. Test date is marked on tank.
E. Documentation exists verifying tank is not leaking. A. Tank has a non-functional bottom drain (water draw off) system.
B. Either High/Low level alarms or leak detection.
C. API 653 inspection has been previously performed and is current with a copy of the report available, and the next inspection is due within the next year.
D. Documentation does not exist verifying tank is not leaking. A. Tank has visual evidence of physical damage and/or visual signs of fuel stains (weeping).
B. Tank has no bottom drain system.
C. Tank has neither High/Low level alarms or leak detection.
D. API 653 has not been performed, or the results are not available, or the API 653 inspection is past due.
| E. Documentation exists verifying tank is leaking. | 104 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||
| 6 | Storage Operations | F | Underground Storage Tanks | A. Underground tanks are double-walled (tanks part of aircraft hydrant system can be single-walled). |
B. High/Low level alarms and leak detection system.
C. Cathodic protection systems for steel tanks are inspected annually with proper documentation available.
| D. Documentation exists verifying tank is not leaking. | A. Cathodic protection systems for steel tanks have not been inspected in the last year and/or are without the proper documentation. |
| B. Documentation does not exist verifying tank is not leaking. | A. Underground tanks are NOT double-walled (tanks part of aircraft hydrant system can be single-walled). |
B. High/Low level alarms or leak detection system not installed.
C. Cathodic protection system for steel tanks is not installed.
| D. Documentation exists verifying tank is leaking. | 105 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||||||||
| 6 | Storage Operations | F | Pipelines | A. Underground pipelines have functional leak detection system with current annual calibration documentation OR a current annual tightness test. | ||||||||||||
| B. Cathodic protection is inspected annually (on corrodible metallic pipes only) with documentation of the inspection on hand. | A. Underground pipelines do NOT have a functional leak detection system, annual leak detection calibration documentation is within 3 months of expiration and is not programmed for retesting. | |||||||||||||||
| B. Annual Cathodic protection inspection is overdue (on corrodible metallic piping only). | A. Underground pipelines do NOT have a functional leak detection system, do NOT have functional leak detection calibration documentation OR is past due a current annual tightness test. | |||||||||||||||
| B. Underground pipes do not have Cathodic protection (on corrodible metallic piping only). | 203 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||||||||
| 6 | Storage Operations | F | Telephone System | A. Sufficient telephone jacks are available to support current mission requirements (such as FAS, public telephone, fuels operator, etc.). | A. Sufficient telephone jacks available to support current mission requirements (such as FAS, public telephone, fuels operator, etc.). | A. Telephone jacks are not available to support current mission requirements (such as FAS, public telephone, fuels operator, etc.). | 204 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||
| 6 | Storage Operations | F | Exterior Lighting | A. Provides direct or area lighting for: |
-Pedestrian movement.
-Security.
-Signage.
| -Landscape. | A. Not more than 1 of the 4 types of lighting in the GREEN column is missing. | A. Two or more of the 4 types of lighting in the GREEN column are missing. | ||||||||
| B. No exterior lighting exists. | 205 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | ||
| 6 | Storage Operations | F | Drainage | A. Sufficient drainage in place to prevent ponding or flooding. |
B. All drainage within the storage of dispensing area passes through an oil/water separator or drains to a retention pond of a sufficient size.
C. Containment release valves are kept in a closed position and checked for POL sheen before releasing stormwater. A. Drainage is installed but is not sufficient to fully prevent ponding or flooding.
B. Containment release valves exist but are in need of repair.
NOTE: If the valve is seized, it must be seized in the closed position to warrant an Amber rating. A valve frozen in the open position warrants a Red rating. A. Drainage is not installed.
B. Ground is contaminated by spills/leaks.
| C. Containment release valves are kept open at all times to allow stormwater to escape. | 303 | 10 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | |||||||||||
| 6 | Storage Operations | F | Berm Area | A. Berm area is of sufficient size to contain single largest storage release plus sufficient freeboard. | A. Berm area is of sufficient size to contain single largest storage release but insufficient freeboard. | A. Spill berms are not installed, have no freeboard, or are insufficient to contain single largest storage release. | 305 | 6 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | |||||
| 6 | Storage Operations | F | Computer/LAN System | A. Enough LAN outlets are available to support the Facilities Automated System (FAS). | A. Not enough LAN outlets to support the Facilities Automated System (FAS). | A. LAN outlets are not available to support the Facilities Automated System (FAS). | 306 | 6 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | |||||
| 6 | Storage Operations | F | Office Restrooms | A. Restrooms in place for Storage Operations office. | NA | A. Restrooms are NOT in place for Storage Operations office. | 308 | 4 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | |||||
| 6 | Storage Operations | F | Office HVAC (Heating, Ventilation, Air Conditioning) | A. Facility office equipped with an HVAC system. | |||||||||||||||
| B. HVAC is fully operational and has sufficient capacity to meet office climate control requirements. | A. Facility office HVAC does NOT have sufficient capacity to meet office climate control requirements. | A. HVAC system NOT installed in facility office. | 309 | 4 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | |||||||||
| 6 | Storage Operations | F | Landscaping | A. No weeds, vegetation, or combustible material within the grounds of the facility. | A. Maintained vegetation, weeds, or combustible material within the grounds of the facility. | A. Dense vegetation growth or combustible material within the grounds of the facility. | 310 | 4 | Facility Specific Components | 6 | Storage Operations | F | 6 | 6F | |||||
| 6 | Storage Operations | Q | Fencing | A. Security fencing shows no signs of deterioration, damage, or modification. | A. Security fencing functioning but shows signs of deterioration, damage, or modification. | A. Security fencing shows signs of deterioration, damage, or modification that hinder its performance. | 5 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | |||||
| 6 | Storage Operations | Q | Gauging Equipment | A. Gauging equipment is fully operational with no signs of damage or deterioration. | A. Gauging equipment is operational but has signs of damage or deterioration. | A. Gauging equipment is not operational. | 6 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | |||||
| 6 | Storage Operations | Q | Aboveground Storage Tanks | A. Tank surfaces are coated with no signs of chipping, flaking, rusting, weeping of fuel, or denting. | A. Tank surfaces are coated but chipped, flaking, rusting, or with minor denting. | A. Tank surfaces are chipped, flaking, or rusting on over 20% of the surface. | |||||||||||||
| B. Tank has visual evidence of physical damage and/or visual signs of fuel stains (weeping). | 104 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | |||||||||||
| 6 | Storage Operations | Q | Underground Storage Tanks | A. High/Low level alarms and leak detection system is installed and working. | |||||||||||||||
| B. Cathodic protection system for steel tanks is operating. | NA | A. High/Low level alarms or leak detection system installed but not functioning. | |||||||||||||||||
| B. Cathodic protection system for steel tanks is not operating. | 105 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | |||||||||||
| 6 | Storage Operations | Q | Pipelines | A. Aboveground pipes (carbon steel only) are coated with no signs of physical damage or deterioration (weeping fuel, chipping, flaking, or rusting). | A. Aboveground piping shows signs of fuel stains at joints or fittings. | ||||||||||||||
| B. Aboveground piping has chipping or flaking coating or shows evidence of rusting. | A. Aboveground piping shows evidence of fuel leaking. |
B. Aboveground piping is exposed fiberglass reinforced plastic (FRP).
| C. Aboveground carbon steel piping is not coated and is rusting OR has physical damage beyond surface blemishes. | 203 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | ||||||||
| 6 | Storage Operations | Q | Telephone System | A. Telephone jacks are operable. | A. Jacks need minor repairs to work. | A. Existing jacks need major repairs to work. | 204 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | ||
| 6 | Storage Operations | Q | Exterior Lighting | A. More than 90% is working. | A. 75%–90% is working. | A. Less than 75% is working. | 205 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | ||
| 6 | Storage Operations | Q | Drainage | A. Drainage is fully operational with no clogs or obstructions. | ||||||||||||
| B. Containment release valves are kept in a closed position and checked for POL sheen before releasing stormwater. | A. Drainage is operational but is clogged or obstructed. |
B. Containment release valves exist but are in need of repair.
| NOTE: If the valve is seized, it must be seized in the closed position to warrant an Amber rating. A valve frozen in the open position warrants a Red rating. | A. Drainage is not operational. | |||||||||||||||
| B. Containment release valves are kept open at all times to allow stormwater to escape. | 303 | 10 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | ||||||||
| 6 | Storage Operations | Q | Berm Area | A. Berm area is impervious and shows no signs of deterioration or damage. | A. Berm area is showing signs of deterioration or damage. | A. Bermed area exists but shows signs of major damage or deterioration, compromising contained area. | 305 | 6 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | ||
| 6 | Storage Operations | Q | Computer/LAN System | A. LAN outlets work reliably. | A. Existing LAN outlets need minor repairs or operate intermittently. | A. Existing LAN outlets need major repairs. | 306 | 6 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | ||
| 6 | Storage Operations | Q | Office Restrooms | A. Restrooms in full operable condition. | A. Restrooms show signs of damage or deterioration. | A. Restrooms are NOT operable. | 308 | 4 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q | ||
| 6 | Storage Operations | Q | Office HVAC (Heating, Ventilation, Air Conditioning) | A. HVAC is fully operational. | A. Facility office HVAC system is not fully functional. | A. HVAC system is not operable. | 309 | 4 | Facility Specific Components | 6 | Storage Operations | Q | 6 | 6Q |
&"-,Bold"&K00000015 - BULK FUEL FACILITIES&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"&K00000015 - BULK FUEL FACILITIES&"-,Bold"15 - BULK FUEL FACILITIES
&"-,Bold"&K00000015 - BULK FUEL FACILITIES&"-,Bold"15 - BULK FUEL FACILITIES
WB_Print
| WB: | 15 | Meets Army Standard Design Criteria | ||
| Inspected By Builder | FALSE |
| # | Component | Rating Area | Element | Green | Amber | Red | Order | Points | Selection | Comments | Type | Insp Num | Description | Rating Area | For Alt Rows | Compare Cell above for N/A or Needed | Compare Cell below for N/A or Needed | Value | Other Column | Green | Amber | Red | Concatenate | Red Comms1 | Red Comms | Red Comms | Row | 4L above | 4L Below | 4L Total | Capacity Above | Capacity Below | Capacity Total | N/A | Green Points | Amber Points | Red Points | Cmt # |
| 1 | CATCD Agreement | F | Facility Use | The FCC (CATCD) used for this inspection matches the current use of the facility. | NA | The FCC (CATCD) used for this inspection does not match the current use of the facility. | 1 | 10 | Common Components | 1 | CATCD Agreement | F | 1 | 1F | ||||||||||||||||||||||||
| TOTAL | ||||||||||||||||||||||||||||||||||||||
| 2 | Site | F | External Factors | In the estimation of the evaluator the site meets the following criteria: |
- Location is convenient and appropriate.
- Facility function is not limited by the site.
- Resrictions are not present:
-- - Visibility -- - Access -- - Light / Noise
| -- - Safety concerns | A. One criteria applicable to the facility being inspected is not fully acceptable. | A. One or more criteria applicable to the facility being inspected is significantly deficient in the opinion of the evaluator. | 0 | 10 | Common Components | 2 | Site | F | 2 | 2F | |||||||||
| TOTAL | |||||||||||||||||||
| 3 | Antiterrorism | F | Risk Assessment | A. Facility has a current risk assessment or is included in an installation risk assessment. | NA | A. Facility does not have a current risk assessment and is not included in an installation risk assessment. | 0 | 12 | Common Components | 3 | Antiterrorism | F | 3 | 3F | |||||
| 3 | Antiterrorism | F | Recommendations from Risk Assessment | A. All recommendations for the risk assessment have been accomplished. | A. An action plan from the risk assessment created. | ||||||||||||||
| B. Less than 50% of risk assessment recommendations enacted and mitigation in place for the remainder. | A. No Action Plan for risk assessment findings. | ||||||||||||||||||
| B. Less than 50% of risk assessment recommendations enacted and mitigation not in place for the remainder. | 1 | 10 | Common Components | 3 | Antiterrorism | F | 3 | 3F | |||||||||||
| 3 | Antiterrorism | F | Uniform Facilities Criteria (UFC) 4-010-01, DoD Minimum Antiterrorism Standards for Buildings | A. Facility is in compliance with UFC 4-010-01 standards for new facilities, including construction and standoff for parking. | A. Facility is in compliance with UFC 4-010-01 Standards for existing facilities, including construction and standoff for parking. | A. Facility is not in compliance with UFC 4-010-01 Standards. | 2 | 10 | Common Components | 3 | Antiterrorism | F | 3 | 3F | |||||
| 3 | Antiterrorism | F | Facility Antiterrorism Exercises | A. Facility has executed all Antiterrorism Measures during the preceding 12 months. |
B. The Facility conducted an Antiterrorism Exercise that included some AT Measures within the preceding 12 months.
| C. After action reports are on file with the installation or command antiterrorism officer. | A. The Facility has exercised 50% of Antiterrorism Measures during the preceding 12 months. | |||||||||||||||||
| B. The Facility conducted an Antiterrorism exercise that included some AT Measures within the preceding 12 months. | A. The Facility has not exercised Antiterrorism Measures during the preceding 12 months. | |||||||||||||||||
| B. The Facility has not conducted an Antiterrorism Exercise during the preceding 12 months. | 3 | 8 | Common Components | 3 | Antiterrorism | F | 3 | 3F | ||||||||||
| TOTAL | ||||||||||||||||||
| 4 | Accessibility | F | Grounds | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 0 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Building Exterior | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 1 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Lobby | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 2 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Corridors | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 3 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Conveyance -Stairs, Elevator, Escalator | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 4 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Administrative Areas | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 5 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Latrine | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 6 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| 4 | Accessibility | F | Fire Protection | A. Accessible design features are present allowing ease to approach, reach, enter, or use. | NA | A. Accessible design features are not present. | 7 | 10 | Common Components | 4 | Accessibility | F | 4 | 4F | ||||
| TOTAL | ||||||||||||||||||
| 5 | Receiving And Issue Operations | F | Capability | A. Excellent – The size, capacity, or amount of this component meets at least 90% of functional requirements. | A. Marginal – The size, capacity, or amount of this component meets at least 60% of functional requirements. | A. Inadequate – The size, capacity, or amount of this component does not meet at least 60% of functional requirements. | 1 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Containment Berm | A. Containment berm encompasses entire Receiving/Issue area. | A. A containment berm exists, but does not enclose the entire Receiving/Issue Area. | A. No spill containment control is installed in facility. | 5 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Top Loading / Unloading Facility | A. Loading arm, platform, and stairs are installed in facility. | NA | A. Loading arm, platform, or stairs are NOT installed in facility. | 6 | 10 | Facility Specific Components | 5 | Receiving And Issue Operations | F | 5 | 5F | ||||
| 5 | Receiving And Issue Operations | F | Bottom Loading / Unloading Facility | A. Bottom-loading equipment and high flow gravity & ramp loading & off-loading installed. |