LD8_FCM_updated_drawings.pdf

PDF 6 MB Posted

Attached to
Rope Access Bridge Inspections Federal contract opportunity
Solicitation number
W912ES24Q0078
Issued by
Department of the Army Corps of Engineers Engineering District St Paul

About this file

This document is a solicitation for Rope Access Bridge Inspections (Solicitation Number W912ES24Q0078) issued by the Department of the Army Corps of Engineers Engineering District St Paul.

The key requirements are: The contractor shall provide a 3-person rope access inspection team to perform combined routine and Fracture Critical Member (FCM) inspections of U.S. Army Corps of Engineers (USACE) lock and dam service bridges at 4 locations in Minnesota and Wisconsin. The inspections must be completed no later than November 30, 2024. The contractor's team members must have specific qualifications, including NICET Bridge Safety Inspection certification and SPRAT/IRATA rope access certifications. The contractor must develop and submit an operation plan, rigging plan, and safety plan prior to the start of the inspections. The contractor must also provide digital photographs and completed inspection forms to the Bridge Safety Program Manager within 7 days of completing the inspections. The government will provide field books, coding guides, inspection forms, report templates, and previous inspection reports to the contractor.

View the file

Other files for this federal contract opportunity

Other files attached to Rope Access Bridge Inspections, newest first.
File Type Posted
LD7_FCM and FSD 1.pdf PDF
USAF_FCM Plan.pdf PDF
LD8_BIR_FINAL_2019 1.pdf PDF
2019_LSAFs_BIR_Draft_31OCT2019_BC01.pdf PDF
LSAF_FCM Plans.pdf PDF
24Q0078 Amendment.pdf PDF
LD7_BIR_FINAL_2019 1.pdf PDF
2019_USAFs_Pedestrian_Bridge_Inspection_Report.pdf PDF
24Q0078 Solicitation.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Site Plan

FSD

Category D

FSD Category D

Fracture Critical Member

Fracture Critical Members

FSD Category D Fracture Critical Member

FSD Category D

Fracture Critical Members

FSD

Category

D

NOTE: Web stiffeners have been welded

Fracture Critical Member

FSD Category D

Fracture Critical

Members

Fracture Critical Members

Slide Number 1
Slide Number 2
Slide Number 3
Slide Number 4
Slide Number 5
Slide Number 6
Slide Number 7

File details come from the government source that posted it. Updated .