18T00630001_SF30.pdf

PDF 201 KB Posted

Attached to
Wire and Synthetic Rope. Federal contract opportunity
Solicitation number
W912ES18T0063
Issued by
Department of the Army Corps of Engineers Engineering District St Paul

About this file

SF-30

View the file

Other files for this federal contract opportunity

Other files attached to Wire and Synthetic Rope., newest first.
File Type Posted
18T00630003_1449.pdf PDF
18T00630003_SF30.pdf PDF
18T00630002_SF30.pdf PDF
18T00630002_1449.pdf PDF
18T00630001_1449.pdf PDF
18T0063.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

W81G6780816659

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The reason for this amendment is to update the specifications and quantities for the items being procured.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 7

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 11-Apr-2018

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912ES18T0063

X 9B. DATED (SEE ITEM 11)

05-Apr-2018

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

11-Apr-2018

CODE

CONTRACTING DIVISION

USACE - ST. PAUL

180 5TH STREET E SUITE 700

ST. PAUL MN 55101-1678

W912ES 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912ES18T0063

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

SOLICITATION/CONTRACT FORM

The required response date/time has changed from 13-Apr-2018 03:00 PM to 18-Apr-2018 03:00 PM.

SUPPLIES OR SERVICES AND PRICES

CLIN 0001

The CLIN description has changed from 1.25" Diameter Poly – Dac Rope to 1.125" Diameter Poly – Dac Rope.

The CLIN extended description has changed from:

1 – 1/4” - 3 stranded Maxi Flex / Poly – Dac rope. The individual spool lengths will be 600 foot. The minimum required breaking strength is 19,900 lbs.

To:

1 – 1/8” - 3 stranded Poly – Dac rope. The individual spool lengths will be 600 foot. The minimum required breaking strength is 22,500 lbs.

CLIN 0002

The CLIN extended description has changed from:

6x36 WS IWRC R.H. Reg Lay (Galvanized). 300' in length per coil.

6 x 37 wire rope, 300' in length per coil. All wire rope shall be tested and certified to meet and/or exceed the specified breaking force of 39.8 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)

The pricing detail quantity has increased by 6.00 from 2.00 to 8.00.

CLIN 0003

6x36 WS IWRC R.H. Reg Lay (Grease Impregnated) 1.25" Diameter 1,200' in length.

6x37 Construction, 1.25" Diameter, 1,200' in length. The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the specified breaking force of 79.9 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)

CLIN 0004

600' in length per coil

6x37 construction, 600' in length per coil, The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force of 29.4 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow

CLIN 0005

This CLIN has been renumbered to CLIN 0009.

The CLIN description has changed from 7/8"Diameter Wire Cable to Deleted Line.

The pricing detail quantity has decreased by 6.00 from 6.00 to 0.00.

CLIN 0006

6x37 construction, 600' in length per coil, The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force of 29.4 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow

CLIN 0007

This CLIN has been renumbered to CLIN 0005.

6x19 constrcution, 600' in length per coil, The wire rope is used on sheaves, winches and hoists. Also on our Lorain Crane LRT 300D. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force of 20.6 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)

CLIN 0008

100' in length per coil, Swage End and Swage Eye For equipment winch drum

100' in length per coil, Thimble on working end and Swage Eye (2 3/8” Long x 1 1/2” Diameter) for equipment winch drum

CLIN 0009

This CLIN has been renumbered to CLIN 0007.

100' in length per coil, Swage End and Swage Eye For equipment winch drum

100' in length per coil, Thimble on working end and Swage Eye (2 3/8” Long x 2 ¼” Diameter) for equipment winch drum

DELIVERIES AND PERFORMANCE

The following Delivery Schedule item for CLIN 0002 has been changed from:

DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /

CAGE

3 wks. ADC 2 DREDGE - GOETZ

DREDGE GOETZ 431 NORTH SHORE

DRIVE

FOUNTAIN CITY WI 54629

608-687-9293 FOB: Destination

B6R0TP2

CAGE

3 wks. ADC 8 DREDGE - GOETZ

DREDGE GOETZ 431 NORTH SHORE

DRIVE

FOUNTAIN CITY WI 54629

608-687-9293

The following Delivery Schedule Item has been deleted from CLIN 0007:

CAGE

3 wks. ADC 6 DREDGE - GOETZ

DREDGE GOETZ 431 NORTH SHORE

DRIVE

FOUNTAIN CITY WI 54629

608-687-9293

The following Delivery Schedule Item has been deleted from CLIN 0009:

CAGE

3 wks. ADC 4 DREDGE - GOETZ

DREDGE GOETZ 431 NORTH SHORE

DRIVE

FOUNTAIN CITY WI 54629

608-687-9293

The following have been modified:

SCOPE OF WORK

Request for Wire Rope & Line

Physical Support Branch, Dredge Goetz, request the award of a contract for the purchase of wire rope and line for the Dredge Goetz’s fleet. The Dredge Goetz fleet will be fleeting this winter at the Fountain City Service Base and continue the season in the spring. This contract is to supply wire rope and line for the Dredge Goetz and its supporting equipment.

Scope of Work Purchase of the following for line:

Quantity Coil Line Length (Feet)

Size Minimum Break Force

(Pounds)

Specification

12 600’ ea. 1.125 22,500 lbs 1 – 1/8” - 3 stranded Poly – Dacron rope. The individual spool lengths will be 600 foot. The minimum required breaking strength is 22,500 lbs.

Purchase of the following for Wire Rope:

Quantity Coil Line

Length (Feet)

Size (Dia.)

Construction Class

Minimum Break Force (Tons)

Specification

6 600’ 5/8” 6 x 19 20.6 The wire rope is used on sheaves, winches and hoists.

Also on our Lorain Crane LRT 300D. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL).

The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core.

(IWRC)

5 600’ 3/4” 6 x 37 29.4 The wire rope is used on sheaves, winches and hoists.

All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.

All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)

5 600’ 1” 6 x 37 29.4 The wire rope is used on sheaves, winches and hoists.

All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.

All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)

8 300’ 7/8” 6 x 37 39.8 The wire rope is used on sheaves, winches and hoists.

All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.

All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)

1 1200’ 1-1/4 6 x 37 79.9 The wire rope is used on sheaves, winches and hoists.

All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.

All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)

4 100’ 5/8” Thimble on working end and Swage Eye (2 3/8” Long x 1 1/2” Diameter) for equipment winch drum

4 100’ 1” Thimble on working end and Swage Eye (2 3/8” Long x 2 ¼” Diameter) for equipment winch drum

To ensure compliance with the terms of contract clause 52.219-6 (Paragraph (d)) the contractor shall include with their quote the manufacturer(s) for the material they will deliver under this purchase order.

Delivery Location Information:

Documentation verifying the product being delivered meets or exceeds the listed breaking strength shall be provided at delivery for ALL items specified.

United States Army Corps of Engineers Fountain City Service Base 431 North Shore Drive Fountain City, WI 54629

Hours of Operation:

0700 – 1530: Monday – Friday Closed: Weekends & Holidays

(End of Summary of Changes)

File details come from the government source that posted it.