W81G6780816659
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
The reason for this amendment is to update the specifications and quantities for the items being procured.
1. CONTRACT ID CODE PAGE OF PAGES
J 1 7
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY 11-Apr-2018
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912ES18T0063
X 9B. DATED (SEE ITEM 11)
05-Apr-2018
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer X is extended, is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
11-Apr-2018
CODE
CONTRACTING DIVISION
USACE - ST. PAUL
180 5TH STREET E SUITE 700
ST. PAUL MN 55101-1678
W912ES 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
W912ES18T0063
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SUMMARY OF CHANGES
SECTION SF 1449 - CONTINUATION SHEET
SOLICITATION/CONTRACT FORM
The required response date/time has changed from 13-Apr-2018 03:00 PM to 18-Apr-2018 03:00 PM.
SUPPLIES OR SERVICES AND PRICES
CLIN 0001
The CLIN description has changed from 1.25" Diameter Poly – Dac Rope to 1.125" Diameter Poly – Dac Rope.
The CLIN extended description has changed from:
1 – 1/4” - 3 stranded Maxi Flex / Poly – Dac rope. The individual spool lengths will be 600 foot. The minimum required breaking strength is 19,900 lbs.
To:
1 – 1/8” - 3 stranded Poly – Dac rope. The individual spool lengths will be 600 foot. The minimum required breaking strength is 22,500 lbs.
CLIN 0002
The CLIN extended description has changed from:
6x36 WS IWRC R.H. Reg Lay (Galvanized). 300' in length per coil.
6 x 37 wire rope, 300' in length per coil. All wire rope shall be tested and certified to meet and/or exceed the specified breaking force of 39.8 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
The pricing detail quantity has increased by 6.00 from 2.00 to 8.00.
CLIN 0003
6x36 WS IWRC R.H. Reg Lay (Grease Impregnated) 1.25" Diameter 1,200' in length.
6x37 Construction, 1.25" Diameter, 1,200' in length. The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the specified breaking force of 79.9 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
CLIN 0004
600' in length per coil
6x37 construction, 600' in length per coil, The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force of 29.4 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow
CLIN 0005
This CLIN has been renumbered to CLIN 0009.
The CLIN description has changed from 7/8"Diameter Wire Cable to Deleted Line.
The pricing detail quantity has decreased by 6.00 from 6.00 to 0.00.
CLIN 0006
6x37 construction, 600' in length per coil, The wire rope is used on sheaves, winches and hoists. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force of 29.4 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow
CLIN 0007
This CLIN has been renumbered to CLIN 0005.
6x19 constrcution, 600' in length per coil, The wire rope is used on sheaves, winches and hoists. Also on our Lorain Crane LRT 300D. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force of 20.6 Tons. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
CLIN 0008
100' in length per coil, Swage End and Swage Eye For equipment winch drum
100' in length per coil, Thimble on working end and Swage Eye (2 3/8” Long x 1 1/2” Diameter) for equipment winch drum
CLIN 0009
This CLIN has been renumbered to CLIN 0007.
100' in length per coil, Swage End and Swage Eye For equipment winch drum
100' in length per coil, Thimble on working end and Swage Eye (2 3/8” Long x 2 ¼” Diameter) for equipment winch drum
DELIVERIES AND PERFORMANCE
The following Delivery Schedule item for CLIN 0002 has been changed from:
DELIVERY DATE QUANTITY SHIP TO ADDRESS DODAAC /
CAGE
3 wks. ADC 2 DREDGE - GOETZ
DREDGE GOETZ 431 NORTH SHORE
DRIVE
FOUNTAIN CITY WI 54629
608-687-9293 FOB: Destination
B6R0TP2
CAGE
3 wks. ADC 8 DREDGE - GOETZ
DREDGE GOETZ 431 NORTH SHORE
DRIVE
FOUNTAIN CITY WI 54629
608-687-9293
The following Delivery Schedule Item has been deleted from CLIN 0007:
CAGE
3 wks. ADC 6 DREDGE - GOETZ
DREDGE GOETZ 431 NORTH SHORE
DRIVE
FOUNTAIN CITY WI 54629
608-687-9293
The following Delivery Schedule Item has been deleted from CLIN 0009:
CAGE
3 wks. ADC 4 DREDGE - GOETZ
DREDGE GOETZ 431 NORTH SHORE
DRIVE
FOUNTAIN CITY WI 54629
608-687-9293
The following have been modified:
SCOPE OF WORK
Request for Wire Rope & Line
Physical Support Branch, Dredge Goetz, request the award of a contract for the purchase of wire rope and line for the Dredge Goetz’s fleet. The Dredge Goetz fleet will be fleeting this winter at the Fountain City Service Base and continue the season in the spring. This contract is to supply wire rope and line for the Dredge Goetz and its supporting equipment.
Scope of Work Purchase of the following for line:
Quantity Coil Line Length (Feet)
Size Minimum Break Force
(Pounds)
Specification
12 600’ ea. 1.125 22,500 lbs 1 – 1/8” - 3 stranded Poly – Dacron rope. The individual spool lengths will be 600 foot. The minimum required breaking strength is 22,500 lbs.
Purchase of the following for Wire Rope:
Quantity Coil Line
Length (Feet)
Size (Dia.)
Construction Class
Minimum Break Force (Tons)
Specification
6 600’ 5/8” 6 x 19 20.6 The wire rope is used on sheaves, winches and hoists.
Also on our Lorain Crane LRT 300D. All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force. All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL).
The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core.
(IWRC)
5 600’ 3/4” 6 x 37 29.4 The wire rope is used on sheaves, winches and hoists.
All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.
All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
5 600’ 1” 6 x 37 29.4 The wire rope is used on sheaves, winches and hoists.
All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.
All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
8 300’ 7/8” 6 x 37 39.8 The wire rope is used on sheaves, winches and hoists.
All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.
All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
1 1200’ 1-1/4 6 x 37 79.9 The wire rope is used on sheaves, winches and hoists.
All wire rope shall be tested and certified to meet and/or exceed the minimum specified breaking force.
All wire rope finish shall be “bright” fully lubricated, right regular lay (RRL). The wire rope grade shall be extra improved plow steel (EIP). The core shall be Independent Wire Rope Core. (IWRC)
4 100’ 5/8” Thimble on working end and Swage Eye (2 3/8” Long x 1 1/2” Diameter) for equipment winch drum
4 100’ 1” Thimble on working end and Swage Eye (2 3/8” Long x 2 ¼” Diameter) for equipment winch drum
To ensure compliance with the terms of contract clause 52.219-6 (Paragraph (d)) the contractor shall include with their quote the manufacturer(s) for the material they will deliver under this purchase order.
Delivery Location Information:
Documentation verifying the product being delivered meets or exceeds the listed breaking strength shall be provided at delivery for ALL items specified.
United States Army Corps of Engineers Fountain City Service Base 431 North Shore Drive Fountain City, WI 54629
Hours of Operation:
0700 – 1530: Monday – Friday Closed: Weekends & Holidays
(End of Summary of Changes)