Lead_Test_Analysis.pdf
PDF 632 KB Posted
- Attached to
- Conduit Sandblast and Paint Eau Galle Reservoir
- Solicitation number
- W912ES18B0014
About this file
Lead Test Analysis
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
88 Empire Drive St Paul, MN 55103 Tel: 651-642-1150 Fax: 651-642-1239
RE: Analytical Services
St. Paul, MN 55101
June 11, 2018
Work Order Number: 1802092
Bach Pham Client Manager II
US Army Corps of Engineers bpham@legend-group.com
Enclosed are the results of analyses for samples received by the laboratory on 05/31/18. If you have any questions concerning this report, please feel free to contact me.
Results are not blank corrected unless noted within the report. Additionally, all QC results meet requirements unless noted.
All samples will be retained by Legend Technical Services, Inc., unless consumed in the analysis, at ambient conditions for 30 days from the date of this report and then discarded unless other arrangements are made. All samples were received in acceptable condition unless otherwise noted.
A2LA Accreditation #2950.01
Prepared by, LEGEND TECHNICAL SERVICES, INC
Mr. Kurt Zacharias
180 5th St., Suite 700
Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.
Tel: 651-642-1150 Fax: 651-642-1239
Project:
Project Number:
Project Manager:
Analytical Services
Eau Galle Morning Glory Rehab
Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:
US Army Corps of Engineers
Work Order #: 1802092180 5th St., Suite 700
Sample ID Laboratory ID Date Sampled
ANALYTICAL REPORT FOR SAMPLES
Date ReceivedMatrix
Morning Glory Grating 1802092-01 Paint 05/29/18 13:00 05/31/18 12:10
Sluice Gate Structure 1802092-02 Paint 05/29/18 13:30 05/31/18 12:10
Morning Glory Pole 1802092-03 Paint 05/29/18 14:00 05/31/18 12:10
Shipping Container Information
Default Cooler Temperature (°C):
Received on ice: No Temperature blank was not present Received on ice pack: No Received on melt water: No Ambient: Yes Acceptable (IH/ISO only): Yes
Custody seals: No
Case Narrative:
Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.
Tel: 651-642-1150 Fax: 651-642-1239
Project:
Project Number:
Project Manager:
Analytical Services
Eau Galle Morning Glory Rehab
Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:
US Army Corps of Engineers
Work Order #: 1802092180 5th St., Suite 700
TOTAL METALS ANALYSIS
Legend Technical Services, Inc.
Result Analyte RL Units Dilution Batch Prepared Analyzed Method Notes MDL
Morning Glory Grating (1802092-01) Paint Sampled: 05/29/18 13:00 Received: 05/31/18 12:10
B8F0714 06/08/18 06/11/18 mg/kgLead 250 EPA 6010C77000 7.0 10
Sluice Gate Structure (1802092-02) Paint Sampled: 05/29/18 13:30 Received: 05/31/18 12:10
B8F0714 06/08/18 06/08/18 mg/kgLead 25 EPA 6010C340 0.70 1
Morning Glory Pole (1802092-03) Paint Sampled: 05/29/18 14:00 Received: 05/31/18 12:10
B8F0714 06/08/18 06/11/18 mg/kgLead 250 M3, QR-04EPA 6010C160000 7.0 10
Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced
Tel: 651-642-1150 Fax: 651-642-1239
Project:
Project Number:
Project Manager:
Analytical Services
Eau Galle Morning Glory Rehab
Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:
US Army Corps of Engineers
Work Order #: 1802092180 5th St., Suite 700
Result Units Level Spike
Result Source
%REC
%REC
Limits %RPD
%RPD
Limit Notes Analyte
TOTAL METALS ANALYSIS - Quality Control Legend Technical Services, Inc.
RL MDL
Batch B8F0714 - EPA 3050B (M)
Blank (B8F0714-BLK1) Prepared & Analyzed: 06/08/18
Lead mg/kg< 25 25 0.70
Blank (B8F0714-BLK2) Prepared & Analyzed: 06/08/18
Lead mg/kg< 25 25 0.70
LCS (B8F0714-BS1) Prepared & Analyzed: 06/08/18
Lead mg/kg 95.6 80-120105100 <2525 0.70
LCS Dup (B8F0714-BSD1) Prepared & Analyzed: 06/08/18
Lead mg/kg 95.6 80-120107 2.03102 <2525 0.70 20
Matrix Spike (B8F0714-MS1) Prepared: 06/08/18 Analyzed: 06/11/18 Source: 1802092-03
Lead mg/kg 244 M375-125NR216000 163000250 7.0
Matrix Spike Dup (B8F0714-MSD1) Prepared: 06/08/18 Analyzed: 06/11/18 Source: 1802092-03
Lead mg/kg 249 M3, QR-0475-125NR 49.6130000 163000250 7.0 20
Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced
Tel: 651-642-1150 Fax: 651-642-1239
Project:
Project Number:
Project Manager:
Analytical Services
Eau Galle Morning Glory Rehab
Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:
US Army Corps of Engineers
Work Order #: 1802092180 5th St., Suite 700
Notes and Definitions
QR-04 The RPD value for the MS/MSD was outside of QC acceptance limits. Data was accepted based on LCS and/or LCSD recovery and/or RPD values.
M3 The spike recovery value is unusable since the analyte concentration in the sample is disproportionate to the spike level. The associated blank spike recovery was acceptable.
Sample results reported on a dry weight basis
Relative Percent DifferenceRPD dry
Less than value listed<
Not applicable. The %RPD is not calculated from values less than the reporting limit.NA
MDL Method Detection Limit; Equivalent to the method LOD (Limit of Detection)
RL Reporting Limit
LCS
MS
Laboratory Control Spike = Blank Spike (BS) = Laboratory Fortified Blank (LFB)
Matrix Spike = Laboratory Fortified Matrix (LFM)
Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced
Tel: 651-642-1150 Fax: 651-642-1239
Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced
| 2018-06-11T17:11:39-0500 | |
| Bach Pham |
File details come from the government source that posted it.