Text version

88 Empire Drive St Paul, MN 55103 Tel: 651-642-1150 Fax: 651-642-1239

RE: Analytical Services

St. Paul, MN 55101

June 11, 2018

Work Order Number: 1802092

Bach Pham Client Manager II

US Army Corps of Engineers bpham@legend-group.com

Enclosed are the results of analyses for samples received by the laboratory on 05/31/18. If you have any questions concerning this report, please feel free to contact me.

Results are not blank corrected unless noted within the report. Additionally, all QC results meet requirements unless noted.

All samples will be retained by Legend Technical Services, Inc., unless consumed in the analysis, at ambient conditions for 30 days from the date of this report and then discarded unless other arrangements are made. All samples were received in acceptable condition unless otherwise noted.

A2LA Accreditation #2950.01

Prepared by, LEGEND TECHNICAL SERVICES, INC

Mr. Kurt Zacharias

180 5th St., Suite 700

Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.

Tel: 651-642-1150 Fax: 651-642-1239

Project:

Project Number:

Project Manager:

Analytical Services

Eau Galle Morning Glory Rehab

Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:

US Army Corps of Engineers

Work Order #: 1802092180 5th St., Suite 700

Sample ID Laboratory ID Date Sampled

ANALYTICAL REPORT FOR SAMPLES

Date ReceivedMatrix

Morning Glory Grating 1802092-01 Paint 05/29/18 13:00 05/31/18 12:10

Sluice Gate Structure 1802092-02 Paint 05/29/18 13:30 05/31/18 12:10

Morning Glory Pole 1802092-03 Paint 05/29/18 14:00 05/31/18 12:10

Shipping Container Information

Default Cooler Temperature (°C):

Received on ice: No Temperature blank was not present Received on ice pack: No Received on melt water: No Ambient: Yes Acceptable (IH/ISO only): Yes

Custody seals: No

Case Narrative:

Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced in its entirety.

Tel: 651-642-1150 Fax: 651-642-1239

Project:

Project Number:

Project Manager:

Analytical Services

Eau Galle Morning Glory Rehab

Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:

US Army Corps of Engineers

Work Order #: 1802092180 5th St., Suite 700

TOTAL METALS ANALYSIS

Legend Technical Services, Inc.

Result Analyte RL Units Dilution Batch Prepared Analyzed Method Notes MDL

Morning Glory Grating (1802092-01) Paint Sampled: 05/29/18 13:00 Received: 05/31/18 12:10

B8F0714 06/08/18 06/11/18 mg/kgLead 250 EPA 6010C77000 7.0 10

Sluice Gate Structure (1802092-02) Paint Sampled: 05/29/18 13:30 Received: 05/31/18 12:10

B8F0714 06/08/18 06/08/18 mg/kgLead 25 EPA 6010C340 0.70 1

Morning Glory Pole (1802092-03) Paint Sampled: 05/29/18 14:00 Received: 05/31/18 12:10

B8F0714 06/08/18 06/11/18 mg/kgLead 250 M3, QR-04EPA 6010C160000 7.0 10

Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced

Tel: 651-642-1150 Fax: 651-642-1239

Project:

Project Number:

Project Manager:

Analytical Services

Eau Galle Morning Glory Rehab

Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:

US Army Corps of Engineers

Work Order #: 1802092180 5th St., Suite 700

Result Units Level Spike

Result Source

%REC

%REC

Limits %RPD

%RPD

Limit Notes Analyte

TOTAL METALS ANALYSIS - Quality Control Legend Technical Services, Inc.

RL MDL

Batch B8F0714 - EPA 3050B (M)

Blank (B8F0714-BLK1) Prepared & Analyzed: 06/08/18

Lead mg/kg< 25 25 0.70

Blank (B8F0714-BLK2) Prepared & Analyzed: 06/08/18

Lead mg/kg< 25 25 0.70

LCS (B8F0714-BS1) Prepared & Analyzed: 06/08/18

Lead mg/kg 95.6 80-120105100 <2525 0.70

LCS Dup (B8F0714-BSD1) Prepared & Analyzed: 06/08/18

Lead mg/kg 95.6 80-120107 2.03102 <2525 0.70 20

Matrix Spike (B8F0714-MS1) Prepared: 06/08/18 Analyzed: 06/11/18 Source: 1802092-03

Lead mg/kg 244 M375-125NR216000 163000250 7.0

Matrix Spike Dup (B8F0714-MSD1) Prepared: 06/08/18 Analyzed: 06/11/18 Source: 1802092-03

Lead mg/kg 249 M3, QR-0475-125NR 49.6130000 163000250 7.0 20

Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced

Tel: 651-642-1150 Fax: 651-642-1239

Project:

Project Number:

Project Manager:

Analytical Services

Eau Galle Morning Glory Rehab

Mr. Kurt ZachariasSt. Paul, MN 55101 06/11/18Date Reported:

US Army Corps of Engineers

Work Order #: 1802092180 5th St., Suite 700

Notes and Definitions

QR-04 The RPD value for the MS/MSD was outside of QC acceptance limits. Data was accepted based on LCS and/or LCSD recovery and/or RPD values.

M3 The spike recovery value is unusable since the analyte concentration in the sample is disproportionate to the spike level. The associated blank spike recovery was acceptable.

Sample results reported on a dry weight basis

Relative Percent DifferenceRPD dry

Less than value listed<

Not applicable. The %RPD is not calculated from values less than the reporting limit.NA

MDL Method Detection Limit; Equivalent to the method LOD (Limit of Detection)

RL Reporting Limit

LCS

MS

Laboratory Control Spike = Blank Spike (BS) = Laboratory Fortified Blank (LFB)

Matrix Spike = Laboratory Fortified Matrix (LFM)

Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced

Tel: 651-642-1150 Fax: 651-642-1239

Legend Technical Services, Inc. The results in this report apply to the samples analyzed in accordance with the chain of custody document. This analytical report must be reproduced

2018-06-11T17:11:39-0500
Bach Pham

File details come from the government source that posted it.