This document set comprises comprehensive design drawings and specifications for the fabrication and transportation of the East Connector Bridge at Ensley Engineer Yard in Memphis, Tennessee. The project is a U.S. Army Corps of Engineers initiative (MDC Project Number 3054) and represents a complete set of structural design plans for a floating connector bridge system spanning McKellar Lake and the Mississippi River.
The East Connector Bridge consists of four primary structural components: a landside span, a waterside span, a middle support fixed base, and a middle support float. The fabrication contract encompasses all steel work, including structural piping, tubes, plates, bolts, welds, and marine composite materials. The design incorporates dual floating spans with wheel-supported movement mechanisms, hinge assemblies for transition plates, traffic barriers, pedestrian guardrails, utility racks for electrical and mechanical systems, and associated appendages. Vertical design loads include AASHTO HL-93 vehicle loading, pedestrian live loads of 75 PSF, and specialized equipment loads (forklifts, telehandlers, mobile cranes, water trucks). Horizontal design loads account for 115 MPH wind speeds, river current flow conditions, and seismic considerations with Risk Category IV classification. All structural steel work must conform to AISC standards, AASHTO specifications, AWS welding codes, and applicable marine engineering standards. The contractor is responsible for deadweight surveys, hydrostatic and tightness testing of watertight compartments, and field coordination with the owner regarding water-based delivery locations. The design is issued in draft status for bidding purposes.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9G -0
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
1:
P
M b y
EP
LE
SH
CH
UK
ENSLEY ENGINEER YARD: EAST CONNECTOR BRIDGE
MEMPHIS, TENNESSEE
MDC PROJECT NUMBER: 3054
PROJECT
LOCATION
PROJECT
LOCATION
PROJECT DESIGN TEAM
2185 N. CALIFORNIA BLVD,
SUITE 500
WALNUT CREEK, CA 94596
PHONE: (925) 944-5411
3312 WINBROOK DR,
MEMPHIS, TN 38116
PHONE: (901) 353-1981
GOOGLE EARTH 2021
1201 WESTERN AVENUE, SUITE 200
SEATTLE, WASHINGTON 98101
PHONE: (206) 624-7850 GLOSTEN.COM
17800 NEWHOPE STREET, SUITE B
FOUNTAIN VALLEY, CA 92708
PHONE: (714) 751-3826
MCKELLAR LAKE
M
IS
SI
SS
IP
PI
R
IV
ER
MCKELLAR LAKE
LOCATION MAP
NTS
VICINITY MAP
NTS
ENSLEY
ENGINEER YARD
NEARMAP 2021
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
EC
G-001
JB
JIM BRADY
AZADEH BOZORGZADEH
NOTES:
1. THIS CONTRACT IS FOR FABRICATION AND TRANSPORTATION OF THE
EAST CONNECTOR BRIDGE, OTHER ITEMS ARE NOT IN THIS CONTRACT &
SHOWN FOR INFORMATION ONLY.
2. CONTRACTOR TO COORDINATE DELIVERY LOCATION (ON WATER) WITH
THE OWNER.
DRAFT
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9G -0
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
2:
P
M b y
PH
UA
INDEX OF DRAWINGS
STRUCTURAL
9 S-001 STRUCTURAL NOTES
10 S-101 CONNECTOR BRIDGE BARRIER AND GUARDRAIL PLAN SHEET 1 OF 4
11 S-102 CONNECTOR BRIDGE BARRIER AND GUARDRAIL PLAN SHEET 2 OF 4
12 S-103 CONNECTOR BRIDGE BARRIER AND GUARDRAIL PLAN SHEET 3 OF 4
13 S-104 CONNECTOR BRIDGE BARRIER AND GUARDRAIL PLAN SHEET 4 OF 4
14 S-110 CONNECTOR BRIDGE SPAN FRAMING SHEET 1 OF 3
15 S-111 CONNECTOR BRIDGE SPAN FRAMING SHEET 2 OF 3
16 S-112 CONNECTOR BRIDGE SPAN FRAMING SHEET 3 OF 3
17 S-115 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT FRAMING PLANS
18 S-116 CONNECTOR BRIDGE MIDDLE SUPPORT FIXED BASE PLAN AND ELEVATION
19 S-201 CONNECTOR BRIDGE BARRIER AND GUARDRAIL ELEVATION SHEET 1 OF 4
20 S-202 CONNECTOR BRIDGE BARRIER AND GUARDRAIL ELEVATION SHEET 2 OF 4
21 S-203 CONNECTOR BRIDGE BARRIER AND GUARDRAIL ELEVATION SHEET 3 OF 4
22 S-204 CONNECTOR BRIDGE BARRIER AND GUARDRAIL ELEVATION SHEET 4 OF 4
23 S-301 CONNECTOR BRIDGE SECTIONS
24 S-302 CONNECTOR BRIDGE SPAN SECTIONS AND DETAILS SHEET 1 OF 2
25 S-303 CONNECTOR BRIDGE SPAN SECTIONS AND DETAILS SHEET 2 OF 2
26 S-304 CONNECTOR BRIDGE END ELEVATIONS
27 S-308 CONNECTOR BRIDGE CRADLE PLAN AND SECTIONS
28 S-310 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT SECTIONS 1 OF 3
29 S-311 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT SECTIONS 2 OF 3
30 S-312 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT SECTIONS 3 OF 3
31 S-320 CONNECTOR BRIDGE MIDDLE SUPPORT FIXED BASE SECTIONS 1 OF 2
32 S-321 CONNECTOR BRIDGE MIDDLE SUPPORT FIXED BASE SECTIONS 2 OF 2
33 S-333 CONNECTOR BRIDGE ABUTMENT RUNWAY & HOLD-DOWN SECTIONS & DETAILS
34 S-516 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT - GUIDE PILE CONNECTION
35 S-520 CONNECTOR BRIDGE SPAN DETAILS 1 OF 5
36 S-521 CONNECTOR BRIDGE SPAN DETAILS 2 OF 5
37 S-522 CONNECTOR BRIDGE SPAN DETAILS 3 OF 5
38 S-523 CONNECTOR BRIDGE SPAN DETAILS 4 OF 5
39 S-524 CONNECTOR BRIDGE SPAN DETAILS 5 OF 5
40 S-530 CONNECTOR BRIDGE SPAN CRADLE DETAILS
41 S-540 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT RUB BLOCK DETAILS
42 S-541 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT DETAILS
43 S-550 CONNECTOR BRIDGE MIDDLE SUPPORT FLOAT CONNECTION DETAILS
44 S-560 CONNECTOR BRIDGE MIDDLE SUPPORT FIXED BASE DETAILS 1 OF 2
45 S-561 CONNECTOR BRIDGE MIDDLE SUPPORT FIXED BASE DETAILS 2 OF 2
SHEET
SEQ. NO.
SHEET
REF NO. SHEET NAME
GENERAL
1 G-001 TITLE SHEET
2 G-002 DRAWING INDEX
3 G-003 GENERAL NOTES, LEGEND, SYMBOLS, AND ABBREVIATIONS
4 G-101 EXISTING PLAN
5 G-102 LAYOUT PLAN
CIVIL
6 C-110 EAST CONNECTOR BRIDGE PLAN
7 C-210 EAST CONNECTOR BRIDGE PROFILES
8 C-500 CONNECTOR BRIDGE SECTIONS
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
EBD
G-002
JB
JIM BRADY
AZADEH BOZORGZADEH
SHEET
SEQ. NO.
SHEET
REF NO. SHEET NAME
46 S-570 CONNECTOR BRIDGE - LANDING BARGE TRANSITION PLATE DETAILS 1 OF 2
47 S-571 CONNECTOR BRIDGE - LANDING BARGE TRANSITION PLATE DETAILS 2 OF 2
48 S-572 CONNECTOR BRIDGE - MIDDLE SUPPORT FLOAT TRANSITION PLATE DETAILS
49 S-580 CONNECTOR BRIDGE TRAFFIC BARRIER DETAILS 1 OF 2
50 S-581 CONNECTOR BRIDGE TRAFFIC BARRIER DETAILS 2 OF 2
51 S-584 PEDESTRIAN GUARDRAIL DETAILS
52 S-585 TRAFFIC BARRIER AT ABUTMENT DETAILS
53 S-586 PEDESTRIAN GUARDRAIL AT ABUTMENT DETAILS
54 S-587 LANDING BARGE TRANSITION PLATE BARRIER AND RAIL DETAILS
55 S-588 CONNECTOR BRIDGE UTILITY RACK DETAILS 1 OF 4
56 S-589 CONNECTOR BRIDGE UTILITY RACK DETAILS 2 OF 4
57 S-590 CONNECTOR BRIDGE UTILITY RACK DETAILS 3 OF 4
58 S-591 CONNECTOR BRIDGE UTILITY RACK DETAILS 4 OF 4
59 S-592 MIDDLE SUPPORT FLOAT UTILITY RACK DETAILS
60 S-593 ABUTMENT UTILITY RACK DETAILS
61 S-597 MISCELLANEOUS DETAILS
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9G -0
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:2
AM
b y
EP
LE
SH
CH
UK
GENERAL NOTES:
1. DATUM
1.1. HORIZONTAL DATUM: NORTH AMERICAN DATUM OF 1983 (NAD 83)
1.2. VERTICAL DATUM: NORTH AMERICAN VERTICAL DATUM OF 1988 (NAVD88).
2. ALL WORK IS NEW UNLESS NOTED AS EXISTING (E).
3. ALL PARTS SHIPPED LOOSE SHALL BE ASSEMBLED IN THE SHOP TO CONFIRM FIT UP.
ABBREVIATIONS
& AND
@ AT
% PERCENT
± PLUS/MINUS
# SIZE NUMBER FOR REINFORCING BAR
ABUT ABUTMENT
AC ASPHALT CONCRETE
ANSI AMERICAN NATIONAL STANDARDS INSTITUTE
APPROX APPROXIMATE
AS APPROACH SLAB
ASSY ASSEMBLY
ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS
BC BEGIN CURVE
BHD BULKHEAD
BOT BOTTOM
CB COLLAR BARGE
CL CENTERLINE
CIP CAST-IN-PLACE
CLR CLEAR
COMM COMMUNICATION
CJP COMPLETE JOINT PENETRATION
CONC CONCRETE
CONT CONTINUOUS
DESC DESCRIPTION
DIA, Ø DIAMETER
DWG DRAWING
(E) EXISTING
EA EACH
EB EAST CONNECTOR BRIDGE LINE
EC END CURVE
EEY ENSLEY ENGINEER YARD
EF EACH FACE
EHW EXTREME HIGH WATER
EL, ELEV ELEVATION
ELEC ELECTRICAL
ELW EXTREME LOW WATER
ES EACH SIDE
EQ EQUAL
EW EACH WAY
FFF FINISHED FLOOR ELEVATION
FG FINISH GRADE
FT FEET
FW FIRE WATER
FPS FOOT PER SECOND
GALV GALVANIZED
GB GRADE BREAK
GL GRID LINE
GSP GALVANIZED STEEL PIPE
GR GRADE
HD HEAD
HDG HOT-DIPPED GALVANIZED
HDPE HIGH DENSITY POLYETHYLENE
HS HIGH STRENGTH
HORIZ, H HORIZONTAL
ID INSIDE DIAMETER
JT JOINT
KSI KIPS PER SQUARE INCH
LB POUND
LG LONG
LT LEFT
LWRP LOW WATER RIVER PLANE
MAX MAXIMUM
MIN MINIMUM
MHHW MEAN HIGHER HIGH WATER
MLLW MEAN LOWER LOW WATER
MPH MILES PER HOUR
MUTCD MANUAL ON UNIFORM TRAFFIC CONTROL DEVICES
(N) NEW
N NORTH
N/A NOT APPLICABLE
NAD NORTH AMERICAN DATUM
NAVD NATIONAL AMERICAN VERTICAL DATUM
NIC NOT IN CONTRACT
NO.,# NUMBER, POUND
NSFS NEAR SIDE FAR SIDE
NTS NOT TO SCALE
OFF OFFSET
OC ON CENTER
OD OUTSIDE DIAMETER
OG ORIGINAL GRADE
OH OPPOSITE HAND
OPP OPPOSITE
PI POINT OF INTERSECTION
PL PLATE
PC PILE CLUSTER
PJP PARTIAL JOINT PENETRATION
POC POINT OF CURVATURE
PVC POLYVINYL CHLORIDE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT OF TANGENT
PW POTABLE WATER
R RADIUS
REF REFERENCE
REINF REINFORCING
REQD REQUIRED
RT RIGHT
S SOUTH
SEQ. SEQUENCE
SF SQUARE FOOT
SHT SHEET
SIM SIMILAR
SPA SPACES
SPEC SPECIFICATION
SS STAINLESS STEEL
ST STRING-OUT LINE
STA STATION
STD STANDARD
STIFF STIFFENER
SYMM SYMMETRICAL
T & B TOP AND BOTTOM
TOC TOP OF CURB
TOW TOP OF WALKWAY
TYP TYPICAL
UB UTILITY BARGE
UHMW ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE
UTM UNIVERSAL TRANSVERSE MECATOR
UON UNLESS OTHERWISE NOTED
VERT, V VERTICAL
W/ WITH
WP WORK POINT
WT BHD WATERTIGHT BULKHEAD
PROJECT FEATURE
EXISTING FEATURE
EXISTING CONTOUR
FINISH GRADE CONTOUR
SURVEY CONTROL POINT
WORK POINT
SOIL BORING
DEADMAN
LEGEND AND SYMBOLS
B-X
CROSS-REFERENCE LEGEND
SECTION IDENTIFICATION
SHEET WHERE
SHOWN
D
C
B
A
NOTE:
LETTER AND NUMBER COMBINATION INDICATE IDENTIFICATION OF SECTION,
DETAIL OR VIEW. IDENTIFICATION IS BASED ON THE LOCATION ON THE
SHEET WHERE SHOWN. WHEN REFERENCING DRAWING INFORMATION
BETWEEN SHEETS BOTH THE IDENTIFICATION AND THE SHEET ARE QUOTED
TOGETHER - EITHER IN CALLOUT FORMAT AS SHOWN ABOVE OR IN THE
FORM "VIEW NO./SHEET NO." (A1/S-101).
D
C
B
A
A1
B1
C1
D1
DETAIL/SECTION
IDENTIFICATION
WHERE SHOWN
(SEE NOTE)
DETAIL IDENTIFICATION
SHEET WHERE
SHOWN
234567
1234567
A2
B2
C2
D2
A3
B3
C3
D3
A4
B4
C4
D4
A5
B5
C5
D5
A6
B6
C6
D6
A7
B7
C7
D7
B2 C-102
A1 S-101
A5 S-303
SAMPLE VIEW TITLE
SCALE: NTS
SHEET WHERE
SECTION/DETAIL TAKEN
(SEE NOTE)
LOCATION ON SHEET
(SEE NOTE)
PHOTO IDENTIFICATION
SHEET WHERE
SHOWN
DIRECTION OF
THE PHOTO
CD101
B7
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
G-003
JB
JIM BRADY
AZADEH BOZORGZADEH
220 220 230230
180 180
166 168
176 174
168 166
E2
E2
E2
N12744000
N12745000
N12746000
E2
N12747000
E2
E2
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9G -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:4
AM
b y
EP
LE
SH
CH
UK
EXISTING PLAN
SCALE: 1" = 200'
200' 0' 200' 400'
SCALE: 1''=200'
VESSEL LAUNCH
RAMP AREA
WEST RAMP
STRING-OUT
EAST RAMP
RAILROAD
TRESTLE
FOUNDATION
RIVERPORT ROAD
RAILROAD TRACK
W M
ITC
H
ELL R
D
NEARMAP 2021
MCKELLAR LAKE
ENSLEY ENGINEER YARD
NOTES:
1. AERIAL BACKGROUND MAP IS BASED ON NEARMAP
2021 DATA.
GATE
LEVEE ROAD
OUTLINE OF DREDGE
BOUNDARY OF CUT
BY OTHERS, NIC
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
EC
G-101
JB
JIM BRADY
AZADEH BOZORGZADEHFOR INFORMATION
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9G -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
9:
A
M b y
EP
LE
SH
CH
UK
200' 0' 200' 400'
SCALE: 1''=200'
PC-1 PC-2 PC-4 PC-5 PC-6 PC-7
PC-8
PC-11
PC-10
PC-12 PC-13 PC-14 PC-15
PC-16
PC-17
PC-18 PC-19 PC-20
PC-21
PC-22
PC-23
PC-24
PC-25
PC-26
PC-27
PC-28
PC-29 PC-30 PC-31
PC-9
2226.3' 1906.2' 1076.0'±
STRING-OUT
FLOAT, TYP
(E) DEADMAN, TYP
PILE CLUSTER FOR
STRING-OUT, TYP
(NOT PART OF
CONTRACT)
EAST CONNECTOR BRIDGE
(SEE NOTE 1 & 2)
EAST LANDING
BARGE
(E) WEST RAMP
PLAN
SCALE: 1" = 200'
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
EP
EBD
G-102
JB
JIM BRADY
AZADEH BOZORGZADEH
NOTES:
1. THIS CONTRACT IS FOR FABRICATION AND TRANSPORTATION OF THE
EAST CONNECTOR BRIDGE, OTHER ITEMS ARE NOT IN THIS CONTRACT &
SHOWN FOR INFORMATION ONLY.
2. CONTRACTOR TO COORDINATE DELIVERY LOCATION (ON WATER) WITH
THE OWNER.
NIC
9+00 10+00 11+00 12+00 13+00 14+00 15+00
+0
+0
+0
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9C -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
9:
A
M b y
EP
LE
SH
CH
UK
PLAN
SCALE: 1" = 20'
20' 0' 20' 40'
SCALE: 1''=20'
MIDDLE
SUPPORT FLOAT
GUIDE PILE, TYP, NIC
ABUTMENT
LANDSIDE SPAN CL ROADWAY,
SEE NOTE 1
"EB" LINEWP 2
STRING-OUT
FLOATS, TYP, NIC
PEDESTRIAN
WALKWAY, TYP
LANDING BARGE, NIC
PILE CLUSTER, TYP, NIC
MCKELLAR LAKE
APPROX LIMITS OF
ROCK SLOPE
PROTECTION
CL MIDDLE SUPPORT
"EB" STATION 11+76
(E) DEADMAN, TYP
EAST ELECTRICAL SUBSTATION
EQUIPMENT FOUNDATION, NIC
WEST GB
SHOULDER, TYP
EAST GB
NOTES:
1. UTILITIES SUPPORT, TRANSITION PLATES, AND BARRIERS
ARE NOT SHOWN FOR CLARITY.
2. EAST CONNECTOR BRIDGE SCOPE OF WORK COMPRISES
4 PRIMARY ITEMS:
· LANDSIDE SPAN
· WATERSIDE SPAN
· MIDDLE SUPPORT FIXED BASE
· MIDDLE SUPPORT FLOAT.
(E) WATER LINE
WEIGHT LIMIT SIGN
FOR CONNECTOR
BRIDGE AND WEIGHT
LIMIT SIGN FOR
STRING-OUT, NIC
DOWN GRADE SIGN, AND
SPEED LIMIT SIGN , NIC
WATERSIDE SPAN
(E) EDGE OF ROAD
EDGE OF
(E) ROAD
EDGE OF
SHOULDER, TYP
EDGE OF
ROAD, TYP
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
EC
C-110
JB
JIM BRADY
AZADEH BOZORGZADEH
EAST CONNECTOR BRIDGE
SEE NOTE 2
9+00 10+00 11+00 12+00 13+00 14+00 14+50
9+00 10+00 11+00 12+00 13+00 14+00 14+50
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9C -2
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
9:
A
M b y
EP
LE
SH
CH
UK
LANDSIDE SPAN GUIDE PILE, TYP, NIC MIDDLE SUPPORT
FLOAT WATERSIDE SPAN EAST LANDING BARGE, NIC
APPROX
OG
MIDDLE SUPPORT
FIXED BASE
ABUTMENT, NIC
LANDSIDE SPAN
GUIDE PILE, TYP, NIC
WATERSIDE SPAN
EAST LANDING BARGE, NIC
500YR WATER
SURFACE
EL 227.19'
EXTREME LOW
WATER
EL 170.00'
ABUTMENT, NIC
20' 0' 20' 40'
SCALE: 1''=20'
LOW WATER PROFILE
SCALE: 1" = 20'
HIGH WATER PROFILE
SCALE: 1" = 20'
FG
EL
EV
AT
IO
N
(F T)
EL
EV
AT
IO
N (F
T)
APPROX OG
FG
FG
APPROX OG
SEE NOTE 1
NOTES:
1. PILE CLUSTERS FOR THE LANDING BARGE ARE NOT
SHOWN FOR CLARITY.
2. BRIDGE BARRIER, UTILITIES, AND OTHER FEATURES
FOR THE BRIDGE NOT SHOWN FOR CLARITY.
3. BRIDGE PROFILE SHOWN AT CL OF BRIDGE.
4. NO EARTHWORK IN CONTRACT
SEE NOTE 1
TRANSITION PL, TYP
TRANSITION PL, TYP
-16.83% ±
+3.06% ±
-21.38% ±
-2.19% ±
BOTTOM OF MIDDLE SUPPORT
FIXED BASE SEE S-116 FOR EL
C
LE
AR
AN
C
E MIDDLE SUPPORT
FLOAT
MIDDLE SUPPORT
FIXED BASE
2.
' M
IN
CONNECTOR BRIDGE
CRADLE
CONNECTOR BRIDGE
CRADLE
APPROX OG FG
2.
' M
IN
C
LE
AR
AN
C E
"ST" LINE
"ST" LINE
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
EC
C-210
JB
JIM BRADY
AZADEH BOZORGZADEH
THIS DRAWING SHOWS THE EAST CONNECTOR BRIDGE
COMPLETELY INSTALLED. INSTALLATION IS NOT IN THIS
CONTRACT. ITEMS OTHER THAN THE EAST CONNECTOR
BRIDGE ARE SHOWN FOR INFORMATION.
9+00 10+00 10+50
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9C -5
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
9:
A
M b y
EP
LE
SH
CH
UK
PILE, TYP, NIC
APPROX OG
FGMIDDLE SUPPORT
FIXED BASE
C1
SECTION
SCALE: 3/16" = 1'-0"
8'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 3/16"=1'-0''
D6
PROFILE (ALONG EB)
SCALE: 1" = 10'
FG
APPROX OG
ABUTMENT, NIC
BRIDGE SPAN
MIDDLE SUPPORT FLOAT;
PROVIDE MIN 2'-0"
CLEARANCE BETWEEN FG
AND BOTTOM OF MIDDLE
SUPPORT FLOAT
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
AC
EC
C-500
JB
JIM BRADY
AZADEH BOZORGZADEH
NOTES:
1. THIS DRAWING IS FOR REFERENCE ONLY.
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -0
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
CH
UK
STRUCTURAL NOTES:
1. CODES, STANDARDS AND REFERENCES
· AASHTO 2020, LRFD BRIDGE DESIGN SPECIFICATION, 9TH EDITION.
· AASHTO 2015, STANDARD SPECIFICATIONS FOR STRUCTURAL SUPPORTS FOR HIGHWAY
SIGNS, LUMINAIRS, AND TRAFFIC SIGNALS.
· AISC STEEL CONSTRUCTION MANUAL, FIFTEENTH EDITION.
· ASCE STANDARD ASCE/SEI 7-16: "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES".
· ASCE STANDARD ASCE/COPRI 61-14: “SEISMIC DESIGN OF PIERS AND WHARVES”
· AMERICAN WELDING SOCIETY (AWS) D1.1: 2020 STRUCTURAL WELDING CODE-STEEL.
· AMERICAN WELDING SOCIETY (AWS) D1.6: 2017 STRUCTURAL WELDING CODE- STAINLESS
STEEL.
· INTERNATIONAL BUILDING CODE (IBC) 2018.
· UFC 4-152-01: DESIGN: PIERS AND WHARVES (2017).
· UFC 4-159-03: MOORING DESIGN (3/9/2020).
· ENSLEY ENGINEER YARD FLOATING WHARF STRING-OUT MASTER PLAN, MOFFATT & NICHOL,
CONTR. NO. W912BU-11-D-0006, 2016 JUNE 23.
· ABS RULE FOR BUILDING AND CLASSING STEEL VESSELS FOR SERVICE ON RIVERS AND
INTERCOASTAL WATERWAYS, 2021.
· TITLE 46 CFR SUBCHAPTER F (MARINE ENGINEERING).
· TITLE 46 CFR SUBCHAPTER J (ELECTRICAL ENGINEERING).
2. VERTICAL DESIGN LOADS
· UNIFORM LIVE LOAD FOR DECKING: 400 PSF (ON STRING-OUT FLOATS AND LANDING BARGE, NOT COMBINED WITH VEHICLE/CRANE LOAD).
· PEDESTRIAN LIVE LOAD: 75 PSF (ON CONNECTOR BRIDGE PEDESTRIAN WALKWAY).
· VEHICLE LOAD: AASHTO HL-93 LOADING.
· FORKLIFT: KALMAR DCE 150-6 (33,000 LB LIFTING CAPACITY).
· TELEHANDLER: JLG 2733 (26,600 LB LIFTING CAPACITY).
· MOBILE CRANE: GROVE TMS9000E (90 TON CAPACITY, ONLY PERMITTED ON EAST
CONNECTOR BRIDGES AND LANDING BARGES TRAVELING UNLOADED).
· WATER TRUCK (55,000 LB - 3 AXLE).
· BPNM FLOODWAY OPERATION REQUIREMENTS (ONLY CONSIDERED FOR CONNECTOR BRIDGE
DESIGN AND LANDING BARGE DESIGN) - PERMIT VEHICLE
● SODIUM PERCHLORATE TANKS
● 40,000 LB MAX WEIGHT
● 1 TANK PER TRUCK MAX
● REVETMENT MAT TRUCK
● CURB WEIGHT = 19,800 LB
● EMPTY TRAILER WEIGHT = 15,000 LB
3. HORIZONTAL DESIGN LOADS
3.1. WIND LOAD
· ASCE 7-16 WIND SPEED (3-SECOND GUST) = 115 MPH
· RISK CATEGORY IV
· EXPOSURE CATEGORY C
3.2. CURRENT LOAD (RIVER FLOW)
3.3. SEISMIC LOAD
· RISK CATEGORY: IV
· SITE CLASS: D
· IMPORTANCE FACTOR = 1.5
STRUCTURAL STEEL NOTES:
1. STEEL FRAMING:
STRUCTURAL PIPES ASTM A53 GR B (Fy = 35 KSI)
STRUCTURAL TUBES (RECTANGULAR HSS) ASTM A500 GR C (Fy = 50 KSI)
W & MC SHAPES ASTM A992
CHANNELS & ANGLES ASTM A572 GR 50
WELDED STUDS ASTM A29 TYPE B GR 1020
2. STEEL PLATES: ASTM A572/A572M GR 50.
3. BOLTS: ASTM F3125 GR A325, GALV.
4. PINS: AISI 4140 Fy = 60 KSI.
5. PILES: API 5L-X52 OR ASTM A572 GR 50. PIPE PILE FABRICATION SHALL BE PER API
SPECIFICATIONS 2B. (FOR REFERENCE ONLY)
6. ALL STEEL WORK, INCLUDING ACCESS HOLES AND SNIPES, SHALL BE DONE IN ACCORDANCE
WITH AISC STEEL CONSTRUCTION MANUAL, FIFTEENTH EDITION.
7. ALL WELDS SHALL BE DONE IN ACCORDANCE WITH AWS D1.1/D1.1M: 2020 STRUCTURAL WELDING CODE-STEEL. ALL WELDS FOR SHEAR STUDS SHALL BE IN ACCORDANCE WITH AWS D1.1/D1.1M:
2020 STRUCTURAL WELDING CODE - STEEL SECTION 7.
8. ELECTRODE MATERIAL SHALL HAVE A MINIMUM TENSILE STRENGTH OF 70 KSI AND SHALL
COMPLY WITH AWS D1.1/D1.1M: 2020 STRUCTURAL WELDING CODE STEEL.
9. ANCHOR BOLTS FOR CONNECTOR BRIDGE WHEEL TRACKS SHALL BE STAINLESS STEEL HEAVY
HEX HEAD ASTM A1082 DUPLEX 2205, UON. OTHER ANCHOR BOLTS ASTM F1554 GR 55. (FOR
REFERENCE ONLY)
10. STAINLESS STEEL BOLTS: DUPLEX 2205 ASTM A1082, UON.
11. STAINLESS STEEL TRACK PLATES: DUPLEX 2205 ASTM A240, UON.
12. ALL BUSHINGS AND ISOLATORS SHALL BE CIP MARINE COMPOSITES (OR ENGINEER APPROVED
EQUIVALENT).
13. ALL FIELD WELDS SHALL BE COATED AFTER INSTALLATION AND CONTRACTOR SHALL REPAIR
ANY DAMAGES TO COATING IN THE VICINITY OF THE WELD.
14. ALL DECK PLATES AND TRANSITION PLATES SHALL BE COATED WITH NON-SKID PAINT AS SHOWN
IN SPECIFICATIONS.
UHMW
1. ULTRA HIGH MOLECULAR WEIGHT POLYETHYLENE, VIRGIN.
ELASTOMERIC BEARINGS
1. ELASTOMERIC BEARINGS SHALL BE FIBER REINFORCED.
FLOATING STRUCTURES:
1. ALL FLOATING STRUCTURES WHICH INCLUDE TWO EAST CONNECTOR BRIDGE SPANS, AND
MIDDLE SUPPORT FLOAT SHALL UNDERGO THE FOLLOWING TESTINGS:
A. HYDROSTATIC PRESSURE TESTING OF WATERTIGHT COMPARTMENTS TO THE TOP OF
THE HIGHEST VENT POINT OR TO THE TOP OF DECK SURFACE.
B. TIGHTNESS TESTING OF WATERTIGHT COMPARTMENT BOUNDARIES.
C. TIGHTNESS TESTING OF WATERTIGHT HATCHES, DECK AND BULKHEAD PENETRATIONS.
2. AFTER THE MIDDLE SUPPORT FLOAT IS FULLY CONSTRUCTED AND OUTFITTED THE
CONTRACTOR SHALL BE RESPONSIBLE FOR CONDUCTING A FULL DEADWEIGHT SURVEY FOR
THE PURPOSE OF ESTABLISHING THE AS-BUILT LIGHTSHIP WEIGHT. THE TEST NEED NOT BE
WITNESSED OR APPROVED BY USCG OR CLASSIFICATION SOCIETY BUT SHALL BE IN
ACCORDANCE WITH THE SECTIONS 8.1.1 (INITIAL WALK THROUGH AND SURVEY) AND 8.1.2
(FREEBOARD/DRAFT READINGS) OF ASTM F-1321-21, STANDARD GUIDE FOR CONDUCTING A
STABILITY TEST (LIGHTWEIGHT SURVEY AND INCLINING EXPERIMENT) TO DETERMINE THE LIGHT SHIP DISPLACEMENT AND CENTERS OF GRAVITY OF A VESSEL. THE TEST SHALL BE WITNESSED
AND STAMPED BY A NAVAL ARCHITECT. THE OWNER MAY WITNESS THE TEST. THE OWNER
SHALL RECEIVE NOTICE OF THE SCHEDULED TEST DATE A MINIMUM OF TWO WEEKS PRIOR. THE
GOVERNMENT SHALL RECEIVE A 24-HOUR RESCHEDULING NOTICE. A REPORT COMPLETE WITH
RAW DATA, CALCULATIONS, AND RESULTS SUMMARY SHALL BE PROVIDED TO THE SUBMITTED
FOR REVIEW AND COMMENT.
RETURN
PERIOD
LONGITUDINAL FLOW
VELOCITY (FPS)
TRANSVERSE FLOW
VELOCITY (FPS)
200-YR 3.71 0.56
500-YR 4.00 0.60
SITE SPECIFIC RESPONSE SPECTRUM TIME, SECONDS
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
EBD
S-001
JB
JIM BRADY
JKLMNOPQRSTUVWX
10+00
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
CH
UK
M
AT
C H
L
IN
E
ST
A
+9
SE
E
S-
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
APPROACH SLAB, NIC
LANDSIDE
SPAN
CL ROADWAY STRIPE
"EB" LINE
PEDESTRIAN
WALKWAY
WP 2
ABUTMENT, NIC
TRANSITION PLATE
SEE SHEET S-570
A6 S-301
HATCH, TYP
PLAN
SCALE: 1/4" = 1'-0"
SEE C7
S-585
SEE
PEDESTRIAN GUARDRAIL, TYP
SEE SHEET S-584 INTERIOR TRAFFIC
BARRIER, TYP SEE
SHEET S-580
EXTERIOR
TRAFFIC
BARRIER, TYP
SEE SHEET
S-580
LIGHT POLE, TYP
A7 S-201
B7 S-201
C7 S-201
ELECTRICAL,
WATER, AIR, AND
FIREWATER, NICD7
S-586
UTILITY RACK, TYP
SEE
SEE B6
S-588
B6 S-590
ABUTMENT UTILITY RACK
SEE C7
S-593
HELICAL PILES PIPE SUPPORT,
NIC
SACRIFICIAL PLATE
SEE SHEET S-570
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
EP
EBD
S-101
JB
JIM BRADY
ABCDEFGHI A B C
1 2 3 4 5 6 7 8 9 10 11
11+00 12+00
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
C H
L
IN
E
ST
A
+9
SE
E
S-
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
M
AT
C H
L
IN
E
ST
A
+1
SE
E
S-
LANDSIDE
SPAN
CL ROADWAY STRIPE
"EB" LINE
PEDESTRIAN
WALKWAY, TYP
WATERSIDE
SPAN
TRANSITION
PLATE, TYP
SEE SHEET S-572
MIDDLE
SUPPORT FLOAT
C7 S-301
HATCH, TYP
PLAN
SCALE: 1/4" = 1'-0"
PEDESTRIAN
GUARDRAIL, TYP
SEE SHEET S-584
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
UTILITY RACK, TYP
SEE SHEET S-592
LIGHT POLE, TYP
A6 S-301
C7 S-202
B7 S-202
A7
S-202 ELECTRICAL, WATER,
AIR, AND FIREWATER,
TYP, NIC
UTILITY RACK, TYP
SEE
SEE .
SIM
SEE B6
S-588
SIM
B6 S-588
CHAIN LINK,
FOR DETAILS, SEE A7
S-584
SEE
A7 S-572
SIM
2' -3
8'
-2
TY
P
9'-0"
TYP
6'-0"
TYP
6'-0"
TYP
GUIDE PILE, TYP, NIC
1' -6
TY
P U
O N
6'-0"
TYP
1'-8"
2' -0
4'-0" B1 S-592
1'-6"
TYP
UON
30° 60°
5'-3"
1' -7
100°
2' -1
B6 S-590
4' -1
TY
P
LADDER, TYP
SEE B4
S-597
B7 S-592
FIRE WATER RISER
PIPE SUPPORT, NIC
SACRIFICIAL PLATE, TYP
SEE SHEET S-572
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
EP
EBD
S-102
JB
JIM BRADY
D E F G H I J K L M N
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
C H
L
IN
E
ST
A
+1
SE
E
S-
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
M
AT
C H
L
IN
E
ST
A
+9
SE
E
S-
4CL ROADWAY STRIPE
"EB" LINE
PEDESTRIAN
WALKWAY, TYP
WATERSIDE
SPANHATCH, TYP
PLAN
SCALE: 1/4" = 1'-0"
PEDESTRIAN
GUARDRAIL, TYP
SEE SHEET S-584
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
EXTERIOR
TRAFFIC
BARRIER, TYP
SEE SHEET
S-580
UTILITY RACK, TYP
SEE
LIGHT POLE, TYP
A6 S-203
B6 S-203
C6 S-203
A6 S-301
ELECTRICAL,
WATER, AIR, AND
FIREWATER, NIC B6
S-590
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
EP
EBD
S-103
JB
JIM BRADY
O P Q R S T U V W X
13+00
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
C H
L
IN
E
ST
A
+9
SE
E
S-
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
CL ROADWAY
"EB" LINE
PEDESTRIAN
WALKWAY, TYP
WATERSIDE
SPAN
TRANSITION PLATE
SEE SHEET S-570
LANDING BARGE, NIC
HATCH, TYP
PLAN
SCALE: 1/4" = 1'-0"
PEDESTRIAN
GUARDRAIL, TYP
SEE SHEET S-584
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
EXTERIOR
TRAFFIC
BARRIER, TYP
SEE SHEET
S-580
LIGHT POLE, TYP
A6 S-204
B6 S-204
C6 S-204
A6 S-301
GRATING, TYP, NIC
ELECTRICAL,
WATER, AIR, AND
FIREWATER, NIC UTILITY RACK, TYP
SEE SEE A7
S-589B6
S-590
PEDESTRIAN RAIL,
SEE SHEET S-587
EXTERIOR TRAFFIC
BARRIER, SEE SHEET S-587
SACRIFICIAL PLATE
SEE SHEET S-570
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
EP
MB
S-104
JB
JIM BRADY
ABCDEFGHIJKLMNOPQRSTUVWX
TOP PL 1/2TOP
PL 1
TOP
PL 1 1/2
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
CH
UK
TRANSVERSE DIAPHRAGM
PL 7/16 @ 22'-6" OC, TYP UON
GL C TO GL R
A-FRAME, TYP
@ 7'-6" FROM
TRANSVERSE
DIAPHRAGMS
LONGITUDINAL WEB
7/16 PL , TYP UON
8'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 3/16"=1'-0''
SIDE PL 3/8, TYP, UNO
GL C TO GL T
PL 3/4,
TYP
PL 1, TYP
1. GUARDRAIL POSTS, UTILITY RACKS, AND LIGHT POLES NOT
SHOWN FOR CLARITY.
2. TOP PLATE NOT SHOWN ON TOP FRAMING PLAN.
NOTES:
C7
S-302 MC10 DECK REINFORCEMENT FROM GL A TO
GL V , TYP THROUGHOUT EXCEPT AS NOTED
SEE SHEET S-302 FOR SPACING
TYP
'-0
CL HINGE SUPPORT
AT FLOAT
CL WHEEL
ALIGN,
TYP
CL SPAN
SYMM
ABOUT
CL WHEEL
SUPPORTS
PL 1, TYP
PL 1 1/2,
TYP
END PL 1
C7 S-520
D7 S-303
B7 S-303
150'-9"
WHEEL ASSEMBLY
SEE SHEET S-521
CL HINGE SUPPORT
AT FLOAT
1' -6
5' -0
BOTTOM PL
TOP PL
END PL
END PL
A7 S-304
C7 S-304
3' -0
HOOK BEYOND
'-0
7' -6
TOP PL 3/4
TOP DECK
CROWN
L4x4, TYP
SEE D7
S-522SEE B7
S-522
OH, TYPSIM OH, TYP
BLOCKING PLATE UNDER TRAFFIC
BARRIER POSTS AND AT
MID-POINT OF SPAN, TYP, SEE
OH
SIM
OH
OH
OH
OH
SEE TYPC6
S-524
ABCDEFGHIJKLMNOPQRSTUVWX
CONNECTOR BRIDGE ELEVATION - LANDSIDE SPAN (WATERSIDE SPAN OH)
SCALE: 3/16" = 1'-0"ABUTMENT NOT
SHOWN FOR CLARITY
TOP FRAMING PLAN - LANDSIDE SPAN
SCALE: 3/16" = 1'-0"
PL 1/2, TYP
A5 S-302
A7 S-523
AX FILOR
A7
DETAIL - LANDSIDE WATERTIGHT PARTITION LAYOUT
SCALE: NTS
WT BHD A7
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-110
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
CH
UK
TRANSVERSE
DIAPHRAGM 7/16 PL
@ 22'-6" OC, TYP UON
GL C TO GL R
A-FRAME, TYP
@ 7'-6" FROM
TRANSVERSE
DIAPHRAGMS
LONGITUDINAL WEB
7/16 PL , TYP UON
8'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 3/16"=1'-0''
SIDE PL 3/8, TYP, UON
GL C TO GL T
PL 3/4,
TYP
1. GUARDRAIL POSTS, UTILITY RACKS, AND LIGHT POLES NOT SHOWN FOR CLARITY.
2. TOP PLATE NOT SHOWN ON TOP FRAMING PLAN.
NOTES:
C7
S-302TYP
A B C D E F G H I J K L M N O P Q R S T U V W X
'-0
CL HINGE SUPPORT
AT FLOAT
CL WHEEL
ALIGN,
TYP
CL SPAN
SYMM
ABOUT
CL WHEEL
SUPPORTS
PL 1, TYP
PL 1 1/2,
TYP
PL 1/2, TYP
END PL 1
C7 S-520
D7 S-303
B7 S-303
A7 S-304
C7 S-304
'-0
7' -6
TOP PL 3/4 TOP PL 1/2 TOP
PL 1
TOP
PL 1 1/2
TOP DECK
CROWN
L4x4, TYP
BLOCKING PLATE UNDER TRAFFIC
BARRIER POSTS AND AT MID-POINT
OF SPAN, TYP, SEE
SEE D7
S-522 SEE B7
S-522
RIDGE
PL 1/2, TYP
1'-3"
TYP
SEE SIM, TYPC6
S-524
D7 S-523
MC10 DECK REINFORCEMENT FROM GL A TO
GL V , TYP THROUGHOUT EXCEPT AS NOTED
SEE SHEET S-302 FOR SPACING
A5 S-302
SIM
A XF I L O R
WT BHD A7
A7
DETAIL - WATERSIDE WATERTIGHT PARTITION LAYOUT
SCALE: NTS
TOP FRAMING PLAN - WATERSIDE SPAN
SCALE: 3/16" = 1'-0"
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
MB
S-111
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
/1
/2
4:
P
M b y
PH
UA
8'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 3/16"=1'-0''
C7
S-302 TYP
BOTTOM FRAMING PLAN - WATERSIDE SPAN (PROJECTED) - (LANDSIDE SPAN OH)
SCALE: 3/16" = 1'-0"
A B C D E F G H I J K L M N O P Q R S T U V W X
'-0
3x7'-6" =22'-6" 14x7'-6" =105'-0"
TYPCL HINGE SUPPORT
AT FLOAT
CL SPAN
SYMM
ABOUT
CL WHEEL
SUPPORTS
PL 1, TYP
PL 1 1/2, TYP
PL 3/4
PL 3/4, TYP
END PL 1
CL WHEEL
ALIGN,
TYP
C7 S-520
3' -9
TY
P
B7 S-303
TRANSVERSE
DIAPHRAGM PL, TYP
A-FRAME, TYP
L4x4, TYP
SIDE PL
LONGITUDINAL
WEB PL, TYP
A7 S-304
C7 S-304 2'-9" 4'-9"9" 2'-4"3'-6"7'-6" 1'-8"
BOT PL 3/4 BOT PL 1/2 BOT
PL 1
BOT
PL 1 1/2
GUARDRAIL POSTS, UTILITY RACKS, AND LIGHT POLES NOT SHOWN
FOR CLARITY.
NOTE:
12"Ø INSPECTION HOLE, 6 ON
GL C AND 4 ON GL U . LOCATE
AT MIDPOINT BETWEEN
BULKHEADS, SEE , TYP
24"Ø ACCESS HOLE
LOCATE AT MIDPOINT,
SEE , TYP
D7 S-303
SEE D7
S-522
SEE
B7 S-522
BOT
PL 3/4
C4 S-524
C4 S-524
SIM
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
MB
S-112
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
/1
/2
4:
P
M b y
PH
UA
8'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 3/16"=1'-0''
1. TOP PLATE NOT SHOWN ON TOP FRAMING PLAN.
2. 1/2" PLATE ABOVE MC10 BETWEEN GL & AND GL &
ON GL , , & .
NOTES:
A B C D E F G H I J K
7 - L6x4
@ EQ SPA
A B C D E F G H I J K
L6x6, TYP
PL 3/8,
TYP
DIAGONAL STIFF
PL 1/2x2'-0"
BOTTOM, TYP
L5x5, TYP
PL 1/2,
TYP
11'-3" 11'-3"
6'-3" 4'-10 1/2" 4'-10 1/2" 7'-0" 7'-0" 7'-0" 7'-0" 4'-10 1/2" 4'-10 1/2" 6'-3"
6' -0
6'
-0
6' -0
6'
-0
6' -0
5'
-0
4' -0
7 - L6x4
@ EQ SPA
7 - L6x4
SIM LONG
7 - L6x4
SIM LONG
L6x6, TYP
MC10,
TYP
TOP FRAMING PLAN
SCALE: 3/16" = 1'-0"
BOTTOM FRAMING PLAN
SCALE: 3/16" = 1'-0"
6' -0
5'
-0
4' -0
C7 S-311
A6 S-310
C7 S-310
PL 3/8
MC10
BELOW,
TYP, EA
SIDE
A7 S-311
A7 S-312
C7 S-312
SEE
NOTE 2
L6x6, TYP
SEE
NOTE 2
SEE
NOTE 2
SEE
NOTE 2
CL FLOAT
SYMM
ABOUT
L6x4 NOT
SHOWN
FOR
CLARITY
L6x4, TYP
PL 7/16, TYP
CL SYMM
ABOUT
CL SYMM
ABOUT
CL FLOAT
SYMM
ABOUT
14'-10 1/4"
REMOVABLE
HATCH TOP COVER
PL, TYP, SEE
54"Ø x 3/4" PILE
SLEEVE (TOTAL 6), TYP
C7 S-311
A6 S-310
C7 S-310
A7 S-311
A7 S-312
C7 S-312
TOP DECK
CROWN
TOP PL 1/2, TYP
A7 S-516
END PL 7/16, TYP
WT BHD
PL 1, TYP
SIDE PL, TYP
BOTTOM
PL 1/2, TYP
A7 S-516
C
H I 7 5 4
D
PL 1/2x2'-0"
DIAGONAL
STIFF TOP, TYP
B4 S-550
SIDE PL 7/16, TYP
A7
DETAIL - WATERTIGHT PARTITION LAYOUT
SCALE: NTS
WATERTIGHT
BULKHEAD, TYP
A7
24"Ø ACCESS HOLE
LOCATE AT MIDPOINT
SEE , TYP SIM
PL 1/2,
TYP
PL 3/8,
TYP
PL 1/2,
TYP
L4x3x1/4
TYP @
EQ SPA
UON
B3 S-312
D2 S-541 PL 1/2"x2'-0"
TOP, TYP
PL 1"x2'-0"
TOP, TYP
PL 1/2"x2'-0"
BOTTOM, TYP
PL 1"x2'-0"
BOTTOM, TYP
L6x6, TYP
A K
F
TEST PILE
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-115
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -1
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
CH
UK
1. FLOAT NOT SHOWN FOR CLARITY.
2. ALL DIMENSIONS ON B7 PLAN ARE RELATIVE TO WALL
PLATES. THE EXTRA 1/2" OVERHANG OF TOP AND BOTTOM
PLATING RELATIVE TO WALL PLATING IS SHOWN ON SHEETS
S-320 AND S-321.
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
NOTES:B7
FIXED BASE PLAN
SCALE: 1/4" = 1'-0"
6'-0"31'-9"6'-0"
6' -0
'-0
6' -0
'-0
6' -0
36"Ø x 1 1/4"
GUIDE PILE
(TOTAL 6), NIC
48"Ø x 3/4" PILE
SLEEVE (TOTAL 6)
18'-0" 18'-0"
D7 S-320
C7 S-320
A7 S-320
B7 S-320
B3
ELEVATION
SCALE: 1/4" = 1'-0"
36" Ø GUIDE
PILES, TYP, NIC
EL 240.00'
B3
CL
D3 S-320
CLOSURE PL, TYP
2' -6
TY
P
9'-0"
TYP
9'-0"
TYP 24"Ø ACCESS
OPENING, TYP
18'-10 1/2"
TYP
2' -6
TY
P
24"Ø ACCESS
OPENING
24"Ø ACCESS
OPENING, TYP
6"Ø DRAIN HOLE, TYP
SEE SHEET S-320
8'-0"
TYP
9' -0
TY
P
24"Ø ACCESS
OPENING ON
OUTSIDE WALL,
TYP (TOTAL 7)
ACCESS
OPENING, TYP
A7
ELEVATION
SCALE: 1/4" = 1'-0"
FG
CL PILE, NICCL ACCESS OPENING
5' -0
A7
CL PILE, NIC
CL PILE CL PILE CL PILE
10'-7"
TYP
INTERMEDIATE
FRAME, TYP
C7 S-321
10'-7"
TYP
EL 193.97' EAST
BOTTOM OF MIDDLE
SUPPORT FIXED BASE
PILE CAP, TYP
SEE SHEET
S-516, NIC
OG
FG
11'-3"
FIXED BASE LOW WATER
BRIDGE SUPPORT AT
WATERSIDE SPAN ONLY, TYP
11'-3"
5'-3 1/2"
TYP
10'-6"
TYP
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER AB
AC
MB
S-116
JB
JIM BRADY
JKLMNOPQRSTUVWX
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -2
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
3:
P
M b y
PH
UA
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
M
AT
C H
L
IN
E
ST
A
+9
SE
E
S-
APPROACH SLAB, NIC
LANDSIDE
SPAN
ABUTMENT, NIC
TRANSITION PLATE, TYP
SEE SHEET S-570
LIGHT POLE, TYP
LANDSIDE
SPAN
LANDSIDE
SPAN
TRANSITION PLATE
ABUTMENT HANDRAIL
SEE SHEET S-586
PEDESTRIAN
GUARDRAIL, TYP
SEE SHEET S-584
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
AND S-581
EXTERIOR TRAFFIC
BARRIER, TYP
SEE SHEETS S-580
AND S-581
UTILITY RACK PARTIALLY
SHOWN FOR CLARITY, TYP
SEE
ABUTMENT BARRIER
SEE SHEET S-585
ABUTMENT, NIC
ABUTMENT, NIC
APPROACH SLAB, NIC
SACRIFICIAL PLATE
APPROACH SLAB, NIC
C7 S-101
EXTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
B7 S-101
INTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
A7 S-101
PEDESTRIAN GUARDRAIL UTILITY RACK ELEVATION
SCALE: 1/4"=1'-0"
B1
S-588SEE
ABUTMENT UTILITY RACK
SEE C3
S-593
B6 S-590
HELICAL PILES PIPE
SUPPORT, NIC
TRANSITION PLATE
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-201
JB
JIM BRADY
ABCDEFGHI A B C
1 2 3 4 5 6 7 8 9 10 11
ABCDEFGHI A B C
1 2 3 4 5 6 7 8 9 10 11
ABCDEFGHI A B C
1 2 3 4 5 6 7 8 9 10 11
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -2
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
CH
UK
M
AT
C H
L
IN
E
ST
A
+9
SE
E
S-
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
M
AT
C H
L
IN
E
ST
A
+1
SE
E
S-
LANDSIDE
SPAN
WATERSIDE SPAN
TRANSITION
PLATE, TYP
SEE SHEET S-572
PEDESTRIAN
GUARDRAIL, TYP
SEE SHEET S-584
MIDDLE
SUPPORT FLOAT
MIDDLE
SUPPORT FLOAT
LANDSIDE
SPAN
LANDSIDE
SPAN
WATERSIDE SPAN
WATERSIDE SPAN
SEE SIM, TYP
TRANSITION
PLATE
BEYOND, TYP
TRANSITION
PLATE, TYP
3'-7"
SEE TYP
SEE TYP
4'-6" 3'-7" 3'-7" 4'-6"
4'-6"
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
EXTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
LIGHT POLE, TYP
4'-6" 3'-7"
A7 S-584
B2 S-581
B2 S-581
MIDDLE
SUPPORT FLOAT
MIDDLE
SUPPORT FLOAT
LADDER, GUIDE PILES AND UTILITY RACKS ON MIDDLE SUPPORT
FLOAT NOT SHOWN FOR CLARITY. MIDDLE FLOAT GUIDE PILES - NIC.
NOTE:
A7 S-102
PEDESTRIAN GUARDRAIL UTILITY RACK ELEVATION
SCALE: 1/4"=1'-0"
B7 S-102
INTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
C7 S-102
EXTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
UTILITY RACK PARTIALLY
SHOWN FOR CLARITY, TYP
SEE
3'-7"
3'-7"
B1 S-588
SEE .
SIM
B1 S-588
SEE .
SIM SEE A7
S-584
B6 S-590
B7
S-550SEE
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-202
JB
JIM BRADY
D E F G H I J K L M N
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -2
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
/1
/2
4:
P
M b y
PH
UA
C H
L
IN
E
ST
A
+1
SE
E
S-
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
M
AT
C H
L
IN
E
ST
A
+9
SE
E
S-
WATERSIDE SPAN
PEDESTRIAN
GUARDRAIL, TYP
SEE SHEET S-584
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
EXTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
LIGHT POLE, TYP
WATERSIDE SPAN
WATERSIDE SPAN
C6 S-103
EXTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
B6 S-103
INTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
A6 S-103
PEDESTRIAN GUARDRAIL UTILITY RACK ELEVATION
SCALE: 1/4"=1'-0"
UTILITY RACK PARTIALLY
SHOWN FOR CLARITY, TYP
SEE B6
S-590
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-203
JB
JIM BRADY
O P Q R S T U V W X
REVISIONS
NO. DATE DESCRIPTION BY APPR'D
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -2
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:2
AM
b y
EP
LE
SH
C H
L
IN
E
ST
A
+9
SE
E
S-
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
WATERSIDE SPAN
TRANSITION PLATE, TYP
SEE SHEET S-570
LANDING BARGE, NIC
PEDESTRIAN
GUARDRAIL, TYP
SEE SHEET S-584
INTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
EXTERIOR TRAFFIC
BARRIER, TYP
SEE SHEET S-580
LIGHT POLE, TYP
TRANSITION PLATE
LANDING BARGE, NIC
SEE
SEE
SEE SIM
TRANSITION PLATE
LANDING BARGE, NIC
WATERSIDE SPAN
WATERSIDE SPAN
A5 S-584
D7 S-581
D7 S-581
A6 S-104
PEDESTRIAN GUARDRAIL UTILITY RACK ELEVATION
SCALE: 1/4"=1'-0"
B6 S-104
INTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
C6 S-104
EXTERIOR TRAFFIC BARRIER ELEVATION
SCALE: 1/4"=1'-0"
UTILITY RACK PARTIALLY
SHOWN FOR CLARITY, TYP
SEE
SEE .B1
S-589
B6 S-590
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-204
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
:5
AM
b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
3:
P
M b y
PH
UA
5'-0"
PEDESTRIAN
WALKWAY
11'-7"
CL ROADWAY
11'-7" 11'-7"
CL ROADWAY
11'-7"
A6 S-104
SECTION AT SPAN EB LINE AT CONNECTOR BRIDGE
SCALE: 3/8" = 1'-0"
S-101, S-102, S-103
C7 S-102
SECTION AT MIDDLE SUPPORT FLOAT
SCALE: 3/8" = 1'-0"
C7 S-580
C4 S-580
4'-0" 0'-0'' 2'-0" 4'-0"
SCALE: 3/8"=1'-0''
C4 S-580
5'-0"
PEDESTRIAN
WALKWAY
C4 S-580
CL BRIDGE SPAN CROWN
CL FLOAT CROWN
1. FOR BRIDGE CROWN SEE SHEET S-302 AND FOR FLOAT
CROWN SEE SHEET S-311.
2. SECTIONS SHOWN ARE LOOKING NORTH.
NOTES:
A C F I K
3'-0"
PEDESTRIAN
GUARDRAIL
INTERIOR
TRAFFIC
BARRIER,
SEE
EXTERIOR TRAFFIC BARRIER, SEE .
BRIDGE SPAN
PEDESTRIAN
GUARDRAIL, SEE
INTERIOR
TRAFFIC
BARRIER,
SEE
INTERIOR TRAFFIC BARRIER, SEE OH
GUIDE PILE, TYP, NIC
MIDDLE SUPPORT FLOAT
UTILITY RACK, SEE
B1 S-584
UTILITY RACK, SEE
SIM
SIM
3'-0"
B7 S-592
SLOPESLOPE
SLOPE SLOPE
B6 S-590
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JB
EP
EBD
S-301
JB
JIM BRADY
AZADEH BOZORGZADEH
UTILITIES (ELECTRICAL &
MECHANICAL) NIC
UTILITIES (ELECTRICAL &
MECHANICAL), NIC
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:1
AM
b y
EP
LE
SH
CH
UK
5' -0
7'-6"
OUTSIDE OF SIDE PL
7'-6" 7'-6"
MC10x25, TYP
CL BRIDGE
MC10x25
L4x4x3/8, TYP
PEDESTRIAN
GUARDRAIL, SEE .
INNER TRAFFIC
BARRIER, SEE S-580
L4x4x3/8, TYP AT
VERTICAL ANGLES
L6x6x3/8
SEE , TYP
C7 S-112
A - FRAME SECTION
SCALE: 3/4" = 1'-0"
S-110, S-111
1'-0" 0'-0'' 6" 1'-0"
SCALE: 1 1/2"=1'-0''
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
A7
DETAIL
SCALE: 1 1/2" = 1'-0"
A3
DETAIL
SCALE: 1 1/2" = 1'-0"
A1
DETAIL
SCALE: 1 1/2" = 1'-0"
A7
A3
A1
TYP
1/4
TYP
L4x4, TYP
MC10
TYP
1/4
1" TY
P
1/4 1/4
TYP
1/4
L6x6
L4x4
PL 7/16
L4x4, TYP
TOP DECK PL
BOTTOM PL
MC10
1/4
TYP 1/4
1/4
SIDE PL, TYP
TOP DECK PL
TOP PL 1/2
BOTTOM PL 1/2
SIDE PL
SIDE PL
3/8, TYP
CL
CL CL CL
CL
NOTES:
1. FOR GUARDRAIL DETAILS, SEE SHEET S-301.
2. UTILITIES ARE NOT IN CONTRACT AND ARE
SHOWN FOR REFERENCE ONLY.
TRAFFIC
BARRIER
SEE S-580
SEE , TYP
SEE , TYP
5' -2
/4
AT
C R
O W
N
2"
TYP UON
30'-0"
5" TY
P
MC10, TYP
1/4
TYP
UON
10"
TYP
UON
3 SPACES @ 1'-8", TYP UON
CL MC10
1'-3 3/8"
BLOCKING PL BEYOND
1/4
MC10
8" TY
P
TYP
TYP
1/4 1/4
BLOCKING PL BELOW
TRAFFIC BARRIER
7'-6"
OUTSIDE OF SIDE PL
TYP
1/4
TYP 1/4
B3 S-584
PEDESTRIAN
GUARDRAIL
UTILITY RACK, SEE
& NOTE 2
TOP DECK PL
MC10, TYP
BLOCKING PL 3/8
3 SIDES
TYP
A5 S-110
DETAIL
SCALE: 1-1/2" = 1'-0"
1/4
WEB PL
7/16, TYP
WEB PL,
TYP
B6 S-590
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER JFJ
PH
PC
S-302
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:2
AM
b y
EP
LE
SH
CH
UK
15'-0"
7'-6"
150'-9"
8'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 3/16"=1'-0''
A B C D E F G H I J K L M N O P Q R S T U V W X
D7 S-112
SECTION
SCALE: 3/16" = 1'-0"
S-110, S-111
BOTTOM PL
TOP PL
END PL
TRANSVERSE
DIAPHRAGM, TYP
WHEELMC10, TYP L6x6, TYP MC10 FLATWISE FROM
GL A TO GL V
SEE
CL HINGE
SUPPORT
5' -0
7'-6"
OUTSIDE OF SIDE PL
7'-6" 7'-6"
CL BRIDGE
PEDESTRIAN
GUARDRAIL, SEE .
INNER TRAFFIC
BARRIER (BEYOND),
SEE S-580
TOP DECK PL
BOTTOM PL
SIDE PL, TYP
TRAFFIC BARRIER,
SEE S-580
5' -2
/4
AT
C R
O W
N
B7 S-112
DIAPHRAGM SECTION
SCALE: 3/4" = 1'-0"
S-110, S-111
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
LONGITUDINAL WEB PL, TYP
(LONG PL CONTINUOUS
THROUGHOUT JOINTS)
TRANSVERSE WATERTIGHT
DIAPHRAGM PL, TYP
C7 S-521
L4x4, TYP
PEDESTRIAN WALKWAY
MC10, TYP
TOP DECK PL
SIDE PL 3/8, TYP
BOTTOM PL
A5
TYPICAL SIDE PLATE CONNECTION DETAIL
SCALE: 3" = 1'-0"
7'-6"
OUTSIDE OF SIDE PL
TOP DECK PL
1/4
1/4 TYP
1/4
LONGITUDINAL
WEB PL
TOP DECK PL
MC10
SEE , TYP
A6
DETAIL
SCALE: 3" = 1'-0"
A7
DETAIL
SCALE: 3" = 1'-0"
A7
A5
A6
-SEE , TYP SEE T & B, TYP
CJP
B3 S-584
UTILITY
RACK, SEE
UTILITIES
NIC
1/4
1/4TYP
CJP
1/4
TYP
B6 S-590
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-303
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:2
AM
b y
EP
LE
SH
CH
UK
8'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 3/16"=1'-0''
HOOK PLATE
PEDESTRIAN WALKWAY
LONGITUDINAL
WEB PL, BEYONDHOOK PLATE, SEE SHEET S-520
BOTTOM OF
BRIDGE BEYOND
BOTTOM OF
BRIDGE AT END
PEDESTRIAN WALKWAY
TRAFFIC BARRIER
POST, TYP. BEYOND
WHEEL
ASSEMBLY, SEE
B2 S-333
BOTTOM OF
BRIDGE AT END
C7 S-110
CONNECTOR BRIDGE FLOAT SUPPORT END ELEVATION
SCALE: 3/4" = 1'-0"
S-111, S-112
A7 S-111
CONNECTOR BRIDGE WHEEL SUPPORT END ELEVATION
SCALE: 3/4" = 1'-0"
S-112
TRAFFIC BARRIER, TYP
PEDESTRIAN
GUARDRAIL
CRADLE, SEE A7
S-308
UTILITY RACK, SEE
UTILITIES NIC
PEDESTRIAN
GUARDRAIL B6
S-590CL BRIDGE
CL CRADLE
CRADLE SHOWN
FOR CLARIFICATION
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-304
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
9/
:3
PM
b y M
W
ES
SN
ER
30'-7"
CL RUNWAY, BUMPER ASSY
CL CRADLE, HINGE ASSY
CL RUNWAY, BUMPER ASSY
14'-0" 14'-0"
15'-3 1/2" 15'-3 1/2"
6'-1 1/2"1'-10 1/2"4'-8 1/2" 1'-6 3/4" 2'-0" 2'-4" 2'-3 3/4" 1'-3 1/2" 1'-5 1/2" 1'-5 1/2"
PL 2 (T&B)WEB PL 2
PL 2 (T&B TYP) WEB PL 2
STIFFENER PL 1,
NSFS, TYP, UON
STIFFENER
PL 1 1/2, NSFS
SYMM ABOUT
6' -6
2' -2
1' -4
2'-7"
TOP OF LANDING
BARGE, NIC
A7
D6 S-530
BUMPER ASSYHINGE ASSY
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
RUNWAY
15'-3 1/2" 15'-3 1/2"
2'-7"
2'-7" 12'-8 1/2" 12'-8 1/2" 2'-7"
2' -6
1'
-6
2' -6
STIFFENER PL 2
STIFFENER PL 2
3 1/2"
B3 S-530
9"
D3 S-530
C5 S-530
B4 S-530
C7 S-530
A7
CRADLE SECTION (ON LANDING BARGE)
SCALE: 3/4" = 1'-0"
C7
CRADLE PLAN (ON LANDING BARGE)
SCALE: 3/4" = 1'-0"
SEE SEE A6
S-530
A7 S-530
CL STIFFENER
PL, TYP
CL CRADLE = CL BRIDGE
HINGE ASSY, BEYOND, TYP
D1 S-530
C1 S-530
B7 S-530
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER AB
RC
MB
S-308
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
/1 /2
4:
P M b y
PH
UA
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
11 10 9 8 7 6
10 9 8 7 6
L6x6x1/2, TYP
SYMM ABOUT CL
SYMM ABOUT CL
GUSSET PL 1/2, TYP
L6x6x1/2, TYP
L6x6, TYP
L5x5x1/2, TYP
L5x5x1/2, TYP
TOP PL
BOTTOM PL
WT BHD
END PL
PL
PL
WT BHD PL
L6x6x1/2, TYP
MC10
L6x6x1/2, TYP
L5x5x1/2, TYP
TOP PL
BOTTOM PL
PL WT BHD PL
DIAG
STIFFENER PL
BEHIND
DIAG
STIFFENER PL
BEHIND
A6 S-115
SECTION @ GRID H (GRIDS D‚ E‚ G SIM)
SCALE: 3/4" = 1'-0"
C7 S-115
SECTION @ GRID B (GRID J SIM)
SCALE: 3/4" = 1'-0"
WT BHD
END PL
1/4 1/4
TYP, T & B
ANGLES
BOTH
DIRECTIONS
1/4 1/4
TYP6-12
6-12
1/4
1/4 TYP
TYP
L6x6
MC10
CJP TOP AND
BOTTOM, TYP
5/16
5/16 TYP
5" TY
P
6-12 6-12
5" TY
P
B4 S-541
B5 S-541
SEE , TYP UONSEE B7
S-541
SEE
1'-0" 0'-0'' 6" 1'-0"
SCALE: 1 1/2"=1'-0''
A7
S-541SEE , TYP
SEE SIMB5
S-541
1/4 TYP
A7
S-541SEE SIM
A7
S-541SEE SIM
A7
S-541SEE SIM
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-310
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
/1 /2
4:
P M b y
PH
UA
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
RUB BLOCKS AND NEOPRENE BASE ARE NOT SHOWN
FOR CLARITY.
NOTE:
A B C D E F
L6x6
MC10x25
SYMM ABOUT FLOAT CL
L6x6x1/2, TYP
L6x6L6x6
L5x5x1/2, TYP
L5x5x1/2, TYP
BOTTOM PL
SIDE PL WT BHD PL 1/2
C7 S-115
SECTION @ GRID 5 (GRIDS 4‚ 7‚ 8 SIM)
SCALE: 3/4" = 1'-0"
L6x6
GUSSET PL 1/2, TYP
MC10x25
WT BHD PL
L6x4x3/8, TYP UON
L6x6
8 EQ SPACES 8 EQ SPACES6"
6"
5/16 5/16
7' -6
5/16 5/16
TYP
5/16 5/16
11 10 9 8 7 6
SYMM ABOUT FLOAT CL
TOP PL
BOTTOM PL
PL
2'-3" 2'-3" 2'-3"
PL 1/2
PL
PL
L5x5x1/2
L6x6
MC10
5/16
A7 S-115
SECTION @ GRID I (GRID C SIM)
SCALE: 3/4" = 1'-0"
2' -0
WT BHD
PL
WT BHD PL
PILE SLEEVE BEYOND
(PILE NOT SHOWN
FOR CLARITY), SEE
SEE NOTE 2
PILE SLEEVE BEYOND
(PILE NOT SHOWN
FOR CLARITY)
2' -0
WT BHD PL WT BHD PL
7' -1
1/
2"
AT
C R
O W
N
PL 1/2
1/4 1/4
TYP6-12
6-12
3 1/2"
6" TY
P
2" TY
P
TOP PL
1/4 1/4
TYP6-12
6-12
1/4 TYP
1/4
1/4 TYP
1/4
5/16TYP
5/16 TYP
END PL
DIAGONAL STIFF
PL 1/2X2'-0"
T & B BEYOND, TYP
PL 1/2
PL 1/2X2'-0"
DIAGONAL STIFF
T & B BEYOND, TYP
1/4
1/4 3 SIDES,
TYP
5/16
TYP
5/16
5/16
TYP
5/16
SEE
TYP
B1 S-541
SEE C7
S-541
C5 S-541
B6 S-540
MC10
TO SIDE
PL, TYP
SEE A7
S-541
SIM
TYP
SEE A4
S-541
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-311
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
/1 /2
4:
P M b y
PH
UA
2'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 3/4"=1'-0''
A B C D E F
L6x6
SYMM ABOUT CL
L6x6L6x6
L5x5x1/2
BEYOND,
TYP
TOP PL
BOTTOM PL
SIDE PL
L6x6
WT BHD PL
L6x6
8 EQ SPACES 8 EQ SPACES
7' -6
A B C
L6x6BOTTOM PL
SIDE PL
PL
7' -6
2' -0
2'
-0
L6x6
C7 S-115
SECTION @ GRID 9 (3 AND 6 SIM)
SCALE: 3/4" = 1'-0"
A7 S-115
SECTION @ GRID 10 (2 SIM)
SCALE: 3/4" = 1'-0"
3'-9"
2' -3
2'-3" 2'-3"
PIPE 24"x1/2"x6"
GRIND EXPOSED
ENDS SMOOTH
L6x6
NO OPENING AT GL 6
PILE SLEEVE BEYOND
(PILE NOT SHOWN
FOR CLARITY)
SEE
SEE NOTE 2
RUB BLOCKS AND BASE SEAT ARE NOT SHOWN FOR CLARITY.
NOTE:
L6x4x3/8, UON
1/4 1/4
TYP
1/4 TYP
TOP PL
1/4
1/4
1/4 TYP @ 2'-0"
T & B PL
BETWEEN
2'-0" T & B PL
DIAGONAL STIFF PL 1/2x2'-0"
NOT SHOWN FOR CLARITY
L5x5
L5x5
L5x5
PL
PL (ONLY WT
BHD AT GL 6)
6-12 6-12
TYP
5/16 5/16
TYP
5/16 5/16
TYP
T&B AT ALL
DIAPHRAGM
PLATES UNO
5/16 5/16
PL
PL
CJP
TYP
4" C
LR
TY
P 2"
C
LR
TY
P
4" CLR
TYP
B3
SECTION
SCALE: 1" = 1'-0"
S-115
B3
1'-0" 0'-0'' 1'-0" 2'-0"
SCALE: 1"=1'-0''
WT BHD PL
5/16
B6 S-540
NO CORNER ACCESS
HOLES AT GL 6 (WT BHD)
1/4 1/4
PL BEYOND
AT GRID 9
L4x3, TYP
B1
SECTION
SCALE: 3" = 1'-0"
B1
6" 0'-0'' 3" 6"
SCALE: 3"=1'-0''
CL HOLE
5/16
PL
3"
L4x3, TYP SIDE PL 1/2
CJP
L5x5
SIDE PL 3/8
1"
1/ 8"1/2"
SB06/17/2026 ISSUED FOR BID0
SCOTT BUTLER BJ
PH
MB
S-312
JB
JIM BRADY
DRAWN
DESIGNED
CHECKED
PROJECT ENGINEER
PROJECT MANAGER
APPROVED
2185 N. California Blvd, Suite 500 Walnut Creek, California 94596
US Army Corps of Engineers
SHEET
REFERENCE NO.
Fi le
P:
\W C\
-0 en sle y st rin g-ou t r ep l\4
_C
AD
D\ ea st c on ne ct or b rid ge d es co pi ng
Ac tiv e\
_D es ig n\
_0 ge ne ra l_ civ il_ st ru ct ur al \9
9S -3
; P lo tte d:
/1 7/
0:
A
M b y
PL
ES
HC
HU
K, E
LE
NA
; S av ed
6/
/2
:2
AM
b y
EP
LE
SH
CH
UK
4'-0" 0'-0'' 4'-0" 8'-0"
SCALE: 1/4"=1'-0''
2'-0" 0'-0'' 2'-0" 4'-0"
SCALE: 1/2"=1'-0''
5' -0
PILE SLEEVE , TYP
TOP PL 1, TYP
INTERMEDIATE
FRAME, TYP
TOP PL 1, TYP
BOT PL 1, TYP
PL 1, TYP
BOTTOM CLOSURE
RING PL, TYP
SEE NOTE 2
PL 1 BEYOND
1. FLOAT NOT SHOWN FOR CLARITY.
2. TOP CLOSURE PLATES & BOTTOM CLOSURE PLATES SHALL BE SHIPPED LOOSE.
NOTE:
TOP PL 1, TYP
BOT PL 1, TYP
PL 1, TYP
PL 1 BEYOND
PILE SLEEVE , TYP
BOTTOM CLOSURE
RING PL, TYP
S…