Combined S-69 Weir Concept Drawings (Draft).pdf

PDF 951 KB Posted

Attached to
Kissimmee River Restoration (KRR) Project, S-69 Weir Repair
Solicitation number
W912EP27Z1CVL
Issued by

About this file

This document is a set of structural design drawings for a subsurface void investigation and repair project issued by the U.S. Army Corps of Engineers, Jacksonville District. The drawings are part of Contract No. W912EP-17-C-0046 and depict repair work for a concrete cap and expansion joints at a weir structure with existing sheet pile construction.

The project scope includes removal and replacement of all cap expansion joints on the north, east, and west legs of the structure, as detailed in Sections A and B of Sheet S-02. Work also encompasses filling voids where sheet pile has separated from the concrete slab using controlled low-strength material or approved flowable fill. The structural repairs involve installation of new concrete caps with #5 closed stirrups at six-inch on-center spacing, #6 continuous reinforcement, welded anchor studs, and 2-inch expansion joints. Specific details include 4-inch chamfers on concrete caps, 2-inch clear spacing for reinforcement, and 2-inch maximum diameter holes to be provided in sheet pile where closed stirrups are located. The drawings indicate existing concrete apron, maintenance drive, existing ramps, and existing expansion joints in slabs. A permanent weir repair completed in 2023 is noted as not within the scope of this contract. Design was completed by G. Sundaresan, drawn by G. Rodriguez, and checked by J. Aquino, with drawings dated and marked as draft at time of issuance.

View the file

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

$S

AJ

D

AT

E$

FI

LE

N

AM

E:

D R

AW

IN

G D

AT

E:

$FILEL$

AN

SI

D

JA

C

KS

O

N

VI

LL

E

D

IS

TR

IC

T

SA

N M

AR

C

O B

LV

D

JA

C

KS

O

N

VI

LL

E

FL

, 3

W

2E P-

-C

-0

SH

EE

T

BA

SE

.D

W G

J.

A

Q U

IN

O

G . R

O D

R

IG

U

EZ

G . S

U N

D

AR

ES

AN

G

EN

ER

AL

P

LA

N

S-01

REMOVE AND REPLACE ALL CAP EXPANSION JOINT,

SEE SECTION B/S-02 (TYP) FOR EAST LEG

REMOVE AND REPLACE ALL CAP EXPANSION JOINT,

SEE SECTION A/S-02 (TYP) FOR NORTH LEG

3" ± SEPARATION SHEET

PILE FROM SLAB OBSERVED.

CONTRACTOR TO FILL IN

VOID WITH CONTROLLED

LOW-STRENGTH MATERIAL

(OR APPROVED FLOWABLE

FILL) WHERE SHEET PILE

HAS SEPARATED FROM

SLAB.

EXISTING CONCRETE CAP

PERM WEIR REPAIR (2023),

NOT IN SCOPE

REMOVE AND REPLACE ALL CAP EXPANSION JOINT,

SEE SECTION B/S-02 (TYP) FOR EAST LEG

N

EAST TRANSITION

EXISTING 560 PZ-22=1027'-7"± EAST LEG

EXISTING 65 PZ-22=119'-2"±

SU

BS

U R

FA

C

E

VO

ID

IN

VE

ST

IG

AT

IO

N

A N

D R

EP

AI

R P

ER

C

O N

TR

AC

T

EXISTING 561 PZ-22=1029'-3"± WEST LEG

EXISTING 65 PZ-22=119'-2"±WEST TRANSITION

PLAN

SCALE: N.T.S.

RAMP EXISTING

EXISTING CONCRETE APRON

MAINTENANCE DRIVE

EXISTING EXPANSION

JOINT IN SLAB (TYP)

RAMP EXISTING

EX

IS

TI

N

G

P

Z-

=4

'-1 0"

N

O R

TH

L

EG

DRAFT

3'-0"

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

US Army Corps of Engineers

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

$S

AJ

D

AT

E$

FI

LE

N

AM

E:

D R

AW

IN

G D

AT

E:

$FILEL$

AN

SI

D

JA

C

KS

O

N

VI

LL

E

D

IS

TR

IC

T

SA

N M

AR

C

O B

LV

D

JA

C

KS

O

N

VI

LL

E

FL

, 3

W

2E P-

-C

-0

SH

EE

T

BA

SE

.D

W G

J.

A

Q U

IN

O

G . R

O D

R

IG

U

EZ

G . S

U N

D

AR

ES

AN

SE

C

TI

O

N A

N D

D

ET

AI

LS

ST

R

U C

TU

R

AL

S-02

2" C

LR

(T

YP

4" CHAMFER (TYP)

C CONCRETE CAPL

2" C

LR

(T

YP

4" CHAMFER (TYP)

C SSPL

9"

CONCRETE CAP REPAIR NORTH LEG

SCALE: N.T.S.

A S-02

CONCRETE CAP REPAIR EAST AND WEST LEGS

SCALE: N.T.S.

B S-02

6" ±

1'-9" ±

MATCH EXISTING

6" 9"

CONCRETE CAP

#5 CLOSED

STIRRUPS

EXISTING SHEET PILE

CONCRETE CAP

#5 CLOSED

STIRRUPS

2" C

LR

(T

YP

EXISTING #6

CONTINUOUS (TYP) EXISTING #6 CONTINUOUS (TYP)

1' -3

2" C

LR

(T

YP

6" ±6" ±

C SSPL

PARTIAL SECTION

SCALE: N.T.S.

C S-02

3'-0" REMOVE AND REPLACE CONCRETE

2" EXPANSION JOINT

3'-0" REMOVE AND REPLACE CONCRETE

#5 @6" OC CLOSED

STIRRUPS EACH

SIDE OF THE JOINT

3"

CLR

(TYP)

PROVIDE 2" MAXIMUM

DIAMETER HOLES IN SHEET

PILE WHERE CLOSED

STIRRUPS ARE LOCATED

C CONCRETE CAPL

S-02 C

TOP OF SHEET PILE

M

AT

C H

E

XI

ST

IIN

G

M

AT

C H

E

XI

ST

IIN

G

6" ±

PARTIAL SECTION

SCALE: N.T.S.

D S-02

#5 @6" OC CLOSED

STIRRUPS EACH

SIDE OF THE JOINT

3"

CLR

(TYP)

PROVIDE 2" MAXIMUM

DIAMETER HOLES IN SHEET

PILE WHERE CLOSED

STIRRUPS ARE LOCATED

TOP OF

SHEET

PILE

3'-0" REMOVE AND REPLACE CONCRETE

2" EXPANSION JOINT

3'-0" REMOVE AND REPLACE CONCRETE

S-02 D

1'-9" ±

MATCH EXISTING

EXISTING SHEET PILE

WELDED ANCHOR

STUDS (EXISTING

TO REMAIN)

WELDED ANCHOR

STUDS (EXISTING

TO REMAIN)

PARTIAL PLAN (TYPICAL)

SCALE: N.T.S.

E S-02

CL EXPANSION

JOINT CONCRETE

CAP

EXISTING

SHEET PILE

EXISTING

CONCRETE

EXISTING

ANCHOR

STUD

WELDED

ANCHOR

STUD

EXISTING #6

REINFORCEMENT

#5 CLOSED

STIRRUPS

DRAFT

S-01 10202026
Sheets and Views
S-01
S-02 10202026
Sheets and Views
S-02

File details come from the government source that posted it. Updated .