AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.
15A. NAME AND TITLE OF SIGNER (Type or print)
30-105-04EXCEPTION TO SF 30
APPROVED BY OIRM 11-84
STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA
FAR (48 CFR) 53.243
HERBERT HOOVER DIKE REHABILITATION PROJECT: REACH 1 CUTOFF WALL GAP CLOSURE, MARTIN AND PALM BEACH COUNTIES, FLORIDA
This amendment is being issued to provide the follow ing:
1. Solicitation Coversheet
2. Section 00010A -- Line Items and Pricing Schedule
3. Instructions for Technical Inquiries and Questions
4. Revised Pre-Proposal Conference and Site Visit Information
The propal due date of 9 August 2016, remains unchanged.
1. CONTRACT ID CODE PAGE OF PAGES
1 8
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)
16C. DATE SIGNED
BY
16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR
(Signature of Contracting Officer)(Signature of person authorized to sign)
8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912EP-16-R-0018
X 9B. DATED (SEE ITEM 11)
08-Jul-2016
10B. DATED (SEE ITEM 13)
9A. AMENDMENT OF SOLICITATION NO.
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.
Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:
(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;
or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN
REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
12. ACCOUNTING AND APPROPRIATION DATA (If required)
13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.
IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE
CONTRACT ORDER NO. IN ITEM 10A.
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).
C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority)
E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
10A. MOD. OF CONTRACT/ORDER NO.
2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)
6. ISSUED BY
3. EFFECTIVE DATE
12-Jul-2016
CODE
USA ENGINEER DISTRICT, JACKSONVILLE
PRUDENTIAL OFFICE BLDG
701 SAN MARCO BLVD
ATTN: CESAJ-CT
JACKSONVILLE FL 32207-8175
W912EP 7. ADMINISTERED BY (If other than item 6)
4. REQUISITION/PURCHASE REQ. NO.
CODE
See Item 6
FACILITY CODECODE
EMAIL:TEL:
Herbert Hoover Dike Rehabilitation Project:
Reach 1 Cutoff Wall Gap Closure, Martin and Palm Beach Counties, Florida
W912EP-16-R-0018 Amendment 0001
SF 30 CONTINUATION SHEET
The purpose of this revision is to provide the following:
1. Solicitation Coversheet
2. Section 00010A -- Line Items and Pricing Schedule
3. Instructions for Technical Inquiries and Questions
4. Revised Pre-Proposal Conference and Site Visit Information
TECHNICAL SPECIFICATIONS:
No Changes
CONTRACTING DOCUMENTS:
DELETE the following in their entirety and REPLACE with attached revised sections:
Section 00700 -- FAR Clauses: 52.236-27 -- Site Visit and 252.236-7001 -- Contract Drawings and Specifications
DRAWINGS:
No Changes
W912EP-16-R-0018
US Army Corps of Engineers Jacksonville District
HHD REHABILITATION PROJECT,
REACH 1 CUTOFF WALL GAP CLOSURE,
MARTIN and PALM BEACH COUNTY, FL
Construction Solicitation and Specifications Volume 1of 2
08 JULY 2016
SECTION 00010A
LINE ITEMS AND PRICING SCHEDULE
W912EP-16-R-0018 00010A-1
ESTIMATED
LINE ITEM DESCRIPTION QUANTITY UNIT UNIT PRICE TOTAL
STRUCTURE S-2 (DEMONSTRATION SECTION)
0001 MOBILIZATION AND DEMOBILIZATION 1 LS
0002 WORK PLATFORM 1 LS
0003 JET GROUT CUTOFF WALL 5200 SF
0004 VERIFICATION CORING/TESTING 6 EA
0005 IMPORT RIPRAP 3160 SY
0006 STAND BY 44 EA (DAY)
STRUCTURE S-2 & STRUCTURE S-351
0007 MOBILIZATION AND DEMOBILIZATION 1 LS
0008 WORK PLATFORM 1 LS
0009 JET GROUT CUTOFF WALL 9085 SF
0010 CONVENTIONAL CUTOFF WALL 42340 SF
0011 VERIFICATION CORING/TESTING 8 EA
0012 IMPORT RIPRAP 2010 SY
TORRY ISLAND
0013 MOBILIZATION AND DEMOBILIZATION 1 LS
0014 WORK PLATFORM 1 LS
0015 CONVENTIONAL CUTOFF WALL 39700 SF
0016 VERIFICATION CORING/TESTING 2 EA
0017 TORRY ISLAND IMPROVEMENTS 1 LS
0018 STAND BY 30 EA (DAY)
STRUCTURE S-352
0019 MOBILIZATION AND DEMOBILIZATION 1 LS
0020 WORK PLATFORM 1 LS
0021 JET GROUT CUTOFF WALL 2000 SF
0022 CONVENTIONAL CUTOFF WALL 17020 SF
0023 VERIFICATION CORING/TESTING 8 EA
0024 IMPORT RIPRAP 770 SY
STRUCTURE S-308
0025 MOBILIZATION AND DEMOBILIZATION 1 LS
0026 WORK PLATFORM 1 LS
0027 JET GROUT CUTOFF WALL 1040 SF
0028 CONVENTIONAL CUTOFF WALL 13520 SF
0029 VERIFICATION CORING/TESTING 4 EA
TOTAL BID (LINE ITEMS 0001 THRU 0029) $______________
GENERAL NOTES:
(1) SEE SECTION 00100, "INSTRUCTIONS TO OFFERORS."
(2) OFFERORS MUST PRICE ALL LINE ITEMS.
(3) SEE CLAUSE "PREPRICING VARIATION IN ESTIMATED QUANTITY" PARA. 999-211-1 (SECTION 00800).
Martin and Palm Beach County, Fl Reach 1 Cutoff Wall Gap Closure, HHD Rehabilitation Project, Amendment 0001
INSTRUCTIONS FOR TECHNICAL INQUIRES AND QUESTIONS
All technical inquiries and questions relating to this solicitation are to be submitted via Bidder Inquiry in ProjNet at https://www.projnet.org/projnet/binKornHome/
To submit and review bid inquiry items, bidders will need to be a current registered user or self register into the system.
To self-register go to the ProjNet web page and follow the steps below.
1. Click the BID tab;
2. Select Bidder Inquiry;
3. Under the Agency drop-down menu select USACE;
4. Enter Key for this solicitation listed below, and a valid e-mail address,
5. Click Login.
6. Fill in all required information and click Create User.
7. Verify that information on next screen is correct and click Continue.
From this page you may view all bidder inquiries or add inquiries. Bidders will receive an acknowledgement of their question via email, followed by an answer to their question after it has been processed by our technical team.
The Solicitation Number is: W912EP-16-R-0018 The Bidder Inquiry Key is: F4327B-7642FJ
THE GOVERNMENT RESERVES THE RIGHT TO LIMIT AND/OR TO NOT RESPOND
TO ANY FURTHER QUESTIONS PERTAINING TO THIS PROJECT RECEIVED
AFTER AUGUST 5, 2016. OFFERORS SHOULD BASE THEIR BIDS ON THE
INFORMATION PROVIDED IN THE SOLICITATION AND ALL ISSUED
AMENDMENTS THERETO.
The call center operates weekdays from 8AM to 5PM U.S. Central Time Zone (Chicago). The telephone number for the Call Center is 800-428-HELP.
HHD Rehabilitation Project, Reach 1 Cutoff Wall Gap Closure, Martin and Palm Beach County, Fl
W912EP-16-R-0018 Amendment 0001
SECTION SF 30 BLOCK 14 CONTINUATION PAGE
SECTION 00010A - LINE ITEMS & PRICING SCHEDULE
SUMMARY OF CHANGES
SECTION 00010 - SOLICITATION, OFFER, AND AWARD
The required performance has changed from:
HERBERT HOOVER DIKE REHABILITATION PROJECT, REACH 1 CUTOFF WALL GAP
CLOSURE, MARTIN AND PALM BEACH COUNTIES, FLORIDA
DESCRIPTION OF WORK: REFER TO SECTION 01 11 00 FOR COMPLETE PROJECT
DESCRIPTION DRAWINGS: SEE DFARS CLAUSE 252.236-7001, IN SECTION 00700.
MAGNITUDE OF CONSTRUCTION IS BETWEEN $10,000,000.00 - $20,000,000.00.
THIS IS AN UNRESTRICTED SOLICITATION. ALL RESPONSIBLE OFFEORS ARE
ENCOURAGED TO PARTICIPATE.
THE NAICS CODE IS 237990 AND THE SMALL BUSINESS SIZE STANDARD IS $36.5 MILLION.
A SITE VISIT WILL BE HELD ON 20 JULY 2016 AT 10:00AM. SEE FAR CLAUSE 52.236-27 IN
SECTION 00100.
A PRE-PROPOSAL CONFERENCE HAS BEEN SCHEDULED FOR 20 JULY 2016 FROM 09:00AM -
10:00AM.
YOU MUST BE REGISTERED IN SAM IN ORDER TO RECEIVE AN AWARD FROM THIS
SOLICITION. THE SAM WEBSITE IS LOCATED AT WWW.SAM.GOV.
To: HERBERT HOOVER DIKE REHABILITATION PROJECT, REACH 1 CUTOFF WALL GAP
CLOSURE, MARTIN AND PALM BEACH COUNTIES, FLORIDA
DESCRIPTION OF WORK: REFER TO SECTION 01 11 00 FOR COMPLETE PROJECT
DESCRIPTION DRAWINGS: SEE DFARS CLAUSE 252.236-7001, IN SECTION 00700.
MAGNITUDE OF CONSTRUCTION IS BETWEEN $10,000,000.00 - $20,000,000.00.
THIS IS AN UNRESTRICTED SOLICITATION. ALL RESPONSIBLE OFFEORS ARE
ENCOURAGED TO PARTICIPATE.
THE NAICS CODE IS 237990 AND THE SMALL BUSINESS SIZE STANDARD IS $36.5 MILLION.
A SITE VISIT WILL BE HELD ON 19 JULY 2016 AT 10:00AM, EDT. SEE FAR CLAUSE
52.236-27 IN SECTION 00100.
A PRE-PROPOSAL CONFERENCE HAS BEEN SCHEDULED FOR 18 JULY 2016 FROM
10:30AM - 11:30AM, EDT. THE CONFERENCE WILL BE HELD VIA WEBINAR:
https://www.teleconference.att.com/servlet/AWMlogin
CONFERENCE NUMBER & INFORMATION: 877-336-1839
ACCESS CODE: 6486219#
PRESS # AGAIN TO JOIN AS A PARTICIPANT.
YOU MUST BE REGISTERED IN SAM IN ORDER TO RECEIVE AN AWARD FROM THIS
SOLICITION. THE SAM WEBSITE IS LOCATED AT WWW.SAM.GOV.
SECTION 00100 - INSTRUCTIONS TO OFFERORS
The following have been modified:
52.236-27 SITE VISIT (CONSTRUCTION) (FEB 1995) (ALTERNATE I) (FEB 1995) (CESAJ
ADAPTATION)
Amendment 0001W912EP-16-R-0018
(a) The clauses at 52.236-2, Differing Site Conditions, and 52.236-3, Site Investigations and Conditions Affecting the Work, will be included in any contract awarded as a result of this solicitation. Accordingly, offerors or quoters are urged and expected to inspect the site where the work will be performed.
(b) An organized site visit has been scheduled for -- 20 July 2016 19 July 2016 at 10:00am, EDT.
(c) Participants will meet at -- (Location will be provided by the contract administration office via telephone. See
(d) below.) Port Mayaca Wayside Park, located on the north side of Kanner Hwy (SR 76) at the intersection with US 441 in Port Mayaca, Florida.
(d) Participants should call Juan Sanchez-Bulted Lynn Stiltner at (561) 790-5506 ext 2003 on or before 19 July 2016 18 July 2016 at 12:00pm, EDT to make arrangements.
(e) Core borings are available. (If available, follow the instructions in the Physical Data paragraph in Section 00 31 32 and 01 11 00 to make arrangements to inspect the borings. Failure to follow the instructions may result in a delay ranging in duration from one hour to 4 days.)
(f) After the site visit, a memorandum summarizing the visit will be posted to www.fbo.gov under the solicitation number. This posting will be strictly for informational purposes only. The memorandum will not become a part of the solicitation. If the solicitation needs to be changed as a result of information obtained during the site visit, a written amendment will be made available to all registered vendors. Questions regarding any information given in the memorandum must be directed to the person whose name appears in item 9 of the Standard Form 1442.
(End of clause)
SECTION 00700 - CONTRACT CLAUSES
The following have been modified:
252.236-7001 CONTRACT DRAWINGS AND SPECIFICATIONS (AUG 2000)
(a) The Government will provide to the Contractor, without charge, one set of contract drawings and specifications, except publications incorporated into the technical provisions by reference, in electronic or paper media as chosen by the Contracting Officer.
W912EP-16-R-0018 Amendment 0001
(b) The Contractor shall--
(1) Check all drawings furnished immediately upon receipt;
(2) Compare all drawings and verify the figures before laying out the work;
(3) Promptly notify the Contracting Officer of any discrepancies;
(4) Be responsible for any errors that might have been avoided by complying with this paragraph (b); and
(5) Reproduce and print contract drawings and specifications as needed.
(c) In general--
(1) Large-scale drawings shall govern small-scale drawings; and
(2) The Contractor shall follow figures marked on drawings in preference to scale measurements.
(d) Omissions from the drawings or specifications or the misdescription of details of work that are manifestly necessary to carry out the intent of the drawings and specifications, or that are customarily performed, shall not relieve the Contractor from performing such omitted or misdescribed details of the work. The Contractor shall perform such details as if fully and correctly set forth and described in the drawings and specifications.
(e) The work shall conform to the specifications and the contract drawings identified on the following index of drawings:
Title Drawing No. File
W912EP-16-R-0018 G-01 Herbert Hoover Dike Rehabilitation Project, Reach 1 Cutoff Wall Gap Closure, Martin and Palm Beach County, Florida
(End of clause)
(End of Summary of Changes)
Amendment 0001W912EP-16-R-0018
| Title Page - HHD Reach 1 Gap Closure.pdf |
| 16R0018SpecV1 |
| US Army Corps |
| Jacksonville District |
| Bid Schedule - HHD Reach 1 Gap Closure.pdf |
| 16R0018SpecV1 |
| 00010A.pdf |
| SJHMITIGATION |
| ProjNet - HHD Reach 1 Gap Closure.pdf |
| 16R0018SpecV1 |
| US Army Corps |
| INSTRUCTIONS FOR TECHNICAL INQUIRES AND QUESTIONS |
| Continuation Sheet - Amendment 0001, HHD Reach 1 Gap Closure.pdf |
| SF 30 CONTINUATION SHEET |