Dam_18_-_Reference_Drawings.pdf
PDF 10 MB Posted
- Solicitation number
- W912EK-16-B-0006
About this file
DAM 18 REFERENCE DRAWINGS
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Original Drawings Sheet Title
10/12.1 Site Map 40/1 General Plan 40/2 Section and Elevation - Roller Gate Pier 40/3 Section and Elevation - Tainter Gate Pier 40/4 Lockwall Abutment - Masonry Details 40/6 Piers Nos. 1-4 & 9-16 - Masonry Details 40/7 Piers Nos. 1-4 & 9-16 - Bridge Landing 40/8 Piers Nos. 1-4 & 9-16 - Reinforcing 40/9 Piers Nos. 1-4 & 9-16 - Abutment A and Lockwall Abutment Reinforcing Schedule
40/10 Pier No. 5 - Masonry Details 40/11 Piers Nos. 6 & 7 - Masonry Details 40/12 Piers Nos. 6 & 7 - Reinforcing 40/13 Pier No. 8 - Masonry Details 40/14 Piers Nos. 5 & 8 - Reinforcing 40/15 Piers Nos. 5-8 - Bridge Landing 40/16 Piers Nos. 5-8 - Reinforcing Schedule 40/17 Abutment A - Masonry Details
40/18A Abutment A Reinforcing 40/19A Abutment B & Retaining Walls - Masonry 40/32 Service Bridge Extension - Masonry 40/33 Service Bridge Extension - Reinforcing 40/42 Fixed Metal - Bulkhead Recesses 40/44 Fixed Metal - Pier Nose Plates & Miscellaneous 40/47 Fixed Metal - Side Seals - 60' x 20' Tainter Gate
Storage Yard Flood Repairs - W912EK-09-R-0054 Sheet Title S-110 New Work Plan S-112 New Work Sections II S-113 New Work Sections III S-115 New Work Sections V S-116 New Work Sections VI S-120 New Fence Details S-121 New Fence and Handrail Details S-130 Slab Plan and Details E-110 New Work Plan
Tainter Gate Pier Repairs - W912EK-10-B-0023 Sheet Title S-017 Observation Platform - New Work Details - Piers 1,3,9,11,13, & 15
Dam 18 Concrete Repairs - Reference Drawing Index
A B a u t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
S-110 S-111
NEW HANDRAIL ON
EXISTING WING WALL
APPROX 45’ IN LENGTH
SLOPE
S L
O P
E
A B a u t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
B
COMPACTED BASE
S-110 S-112
#6 @ 12
(TYP)
#8 @ 12
A B a u t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
SECTION
S-110 S-113
3’-0"
#6 @ 12 (TYP)
#6B @ 12
F
A B a u t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
#6B @ 12 (TYP.)
#6 @ 12
(TYP)
M SECTION
S-110 S-115
ABUTMENT A
#6 ANCHORS
x 6’-0" LONG
EMBED 4’-0"
IN EPOXY
GROUT. SPACE
@ 2’-0" C.C.
A B a u t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
SECTION
S-110 S-116
R
30’-0"
NOTE: DOWNSTREAM WALL REINFORCING NOT SHOWN
SEE S-112 FOR
ABUTMENT B DETAILS
a u t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
M I S
S I S
S I P
P I R
I V
E R
S-120
B M
A
J C
Q
F R
J
S T
O R
A G
E Y
A R
D F
L O
O D
R E
P A
IR
S
S T
O R
A G
E Y
A R
D
S010 S020
4’-0"
PERSONNEL GATE
F
A B
R I C
O N
G A
T E
TERMINAL
POST
CHAIN LINK
FABRIC (TYP)
S010 S020
TYPICAL GATE ELEVATION
CHAIN LINK
FABRIC (TYP)
TOP OF WALL
�" DIA.
TRUSS ROD
1" X �" FLAT
TENSION BAR
GALVANIZED
LINE POST
GALVANIZED
TERMINAL POST
(PULL, END OR
CORNER POST) TYP.
F
A B
R I C
TYPICAL FENCE ELEVATION 2 20 4
SCALE IN FEET
2 20 4
SCALE IN FEET
BRACE RAIL CLAMP
POST
TENSION BAND
TRUSS ROD
(�" DIA. MIN.)
BRACE
RAIL
9-GAGE TIE WIRES
(2’-0" O.C. MAX.)
FABRIC
TRUSS ROD
(�" DIA. MIN.)
TOP OF CONCRETE
NO. 9 GA. WIRE TIE AT
15" O.C. MAX. SPACING
AND WITHIN 4" OF TOP
AND BOTTOM OF FABRIC
FABRIC
LINE POST ATTACHMENTS
TENSION BAR TO
ENGAGE EACH
FABRIC LINK
FABRIC
TENSION BAND
(15" O.C. MAX.
AND WITHIN 4"
FROM TOP AND
BOTTOM OF FABRIC)
1" X �"
TENSION BAR
�" CARRIAGE
BOLT
END OR GATE POST DETAIL
TENSION WIRE
TENSION BAND DETAIL
TOP CAP AND BARBED WIRE
SUPPORT - LINE POST
TOP CAP AND BARBED WIRE
SUPPORT - CORNER OR END POST
35^
1’-0"
TYPICAL FENCE FASTENING DETAILS
NOT TO SCALE
A S
S H
O W
N
N E
W F
E N
C E
D E
T A
IL
S
BOTTOM RAIL
�" CARRIAGE
BOLT WITH
PEEN THREADS
DOUBLE RAIL END
TRUSS ROD AND BAND
BOTTOM RAIL DETAILS
BOTTOM RAIL
NO. 9 GA. WIRE
TIE AT 12" O.C.
MAX. SPACING
TENSION WIRE
BOTTOM RAIL
TOP OF
WALL
TERMINAL
POST
PULL POST
3’-0"
CANTILEVER
S010 S020
ANTI-PERSONNEL PANEL
SCALE SAME AS DETAIL 1
BRACE RAIL ATTACHMENT
* POST SPACING SHALL BE ADJUSTED AT WALL EXPANSION JOINTS TO AVOID INTERFERNCE WITH WATERSTOP
JW
C
D A
M
G L
A D
S T
O N
E I L
L O
C K
A N
D D
A M
N O
TOP OF WALL
NEW FENCE
10’-0" MAX.
A
B C D
E F G H
Sheet
Reference
Number:
S c a l e
D r a w n B y
A B C D E F G H
U .S
A
R M
Y E
N G
I N
E E
R D
I S
T R
I C
T
C O
R P
S O
F E
N G
I N
E E
R S
R O
C K
I S
L A
N D
I L
L I N
O I S
Sheet of XX
D e s i g n e d
B y
C h e c k e d
B y
R e v ie w e d B y
D a t e
P r o j e c t
C o d e
S o l i c i t a t i o n
N u m b e r
D e s c r i p t i o n
D a t e
S y m b o l
R e v i s i o n s
A p p r o v e d
R
US Army Corps
Rock Island District of Engineers
W E
K -0
-R
-0 X
X
X X
X X
X X
X X t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
M I S
S I S
S I P
P I R
I V
E R
S-121
B M
A
J C
Q
F R
J
S T
O R
A G
E Y
A R
D F
L O
O D
R E
P A
IR
S
S T
O R
A G
E Y
A R
D
STEEL POST SCHEDULE
USE AND SECTION
FABRIC 72" TO 96"
2.375" O.D. 2.875" O.D. 4.50" O.D.
POST DIMENSIONS (NOMINAL)TYPE OF
EMBEDMENT
ANCHOR EMBEDMENT SCHEDULE
NOT TO SCALE
TOP OF
CONCRETE
�" PLATE
FENCE POST
8"
1�" 1�"5"
4"
TYPICAL POST BASE(GATE POST SHOWN - LINE POST SHOWN DASHED)
SEE ANCHOR
EMBEDMENT
SCHEDULE
NOTES
CAST IN PLACE 24" 24" 36"
DRILLED & EPOXIED 8" 12" 16"
A S
S H
O W
N
FENCE POST BASE - DETAIL PLAN FENCE POST BASE - SECTION
NOT TO SCALE
MIN. OUTSIDE DIMENSIONS (NOMINAL)
CORNER, END & PULL POSTS
TUBULAR - ROUND 2.875" O.D.
LINE POSTS
TUBULAR - ROUND 2.375" O.D.
TOP, BOTTOM & BRACE RAILS
TUBULAR - ROUND 1.90" O.D.
GATE POST
TUBULAR ROUND 4.50" O.D.
TYPICAL FENCE POST BASE DETAILS FENCE POST & ANCHOR SCHEDULES
�" DIA. HOLES, �" DIA.
STUDS, NUTS, WASHERS,
LOCKWASHERS AND APPROVED
CONCRETE ANCHORAGE
WITH MINIMUM PULLOUT
STRENGTH OF 6000 POUNDS.
1"
TYPICAL - 2�" DIA.
X-STRONG PIPE
TYPICAL 42" RAILING ELEVATION
1" 1"2" 2"
"PL� X 6" X 6"
TYPICAL - 2�" DIA.
X-STRONG PIPE
�" DIA. DRAIN HOLE
3"
RAILING BASE PLATE - SECTION
RAILING BASE PLATE - DETAIL PLAN
TYP.
GRIND
SMOOTH
TYPICAL RAILING CONNECTIONS
TYPICAL RAILING DETAILS
NOTES
N E
W F
E N
C E
A N
D
JW
C
D A
M
G L
A D
S T
O N
E I L
L O
C K
A N
D D
A M
N O
2’-0" 6’-0" MAX 2’-0" 2’-0" 6’-0" MAX 2’-0"
1. ALL ANCHOR BOLTS SHALL BE REPLACED. ANCHOR BOLTS
FOR NEW BASE PLATES SHALL BE 1/2 " DIA. AND SHALL BE
EMBEDDED WITH A MAXIMUM EMBEDMENT OF 3 1/2 " WITH
4000 lb. ULTIMATE PULLOUT, 6000 lb. ULTIMATE SHEAR, AND SHALL BE EPOXY ANCHORED. ALL ANCHOR BOLTS AND
NUTS SHALL BE GALVANIZED.
2. ALL HANDRAIL SHALL BE GALVANIZED AFTER FABRICATION.
3. LENGTHS SHOWN ON HANDRAIL ARE MAXIMUM LENGTHS.
CONTRACTOR SHALL ADJUST HANDRAIL LAYOUT AS REQUIRED
TO FIT LENGTHS AND SPACING OF ABUTMENT WALLS AND
APPURTENANCES. FIELD VERIFY SITE CONDITIONS AND
DIMENSIONS AND SUBMIT HANDRAIL LAYOUT FOR APPROVAL.
H A
N D
R A
IL
D
E T
A
IL
S
1. NEW 8’ HIGH FENCE REQUIRED AROUND PERIMETER
OF STORAGE YARD, 12’ WIDE DOUBLE SWING VEHICLE
AND 4’ WIDE PERSONNEL GATE REQUIRED.
2. ALL FENCE COMPONENTS SHALL SHALL CONFORM
TO ASTM A36 GALVANIZED.
3. ADHESIVE ANCHORS SHALL CONSIST OF THE FOLLOWING:
a. ANCHOR RODS, NUTS AND WASHERS SHALL BE
GALVANIZED STEEL. ANCHOR RODS SHALL BE
ALL-THREAD, 5/8 " DIA. WITH 8" MIN. EMBEDMENT.
b. EPOXY ADHESIVE SHALL PROVIDE A MIN. ALLOWABLE
TENSILE STRENGTH FROM PULLOUT OF 6,000 LBS.
PER ANCHOR-RESIN-CONCRETE INTERFACE.
4. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND
ARE NOT INTENDED TO LIMIT OTHER TYPES OF FENCE
SECTIONS AND METHODS OF INSTALLATION.
1/4" DRAIN HOLE
A
B C D
E F G H
Sheet
Reference
Number:
S c a l e
D r a w n B y
A B C D E F G H
U .S
A
R M
Y E
N G
I N
E E
R D
I S
T R
I C
T
C O
R P
S O
F E
N G
I N
E E
R S
R O
C K
I S
L A
N D
I L
L I N
O I S
Sheet of XX
D e s i g n e d
B y
C h e c k e d
B y
R e v ie w e d B y
D a t e
P r o j e c t
C o d e
S o l i c i t a t i o n
N u m b e r
D e s c r i p t i o n
D a t e
S y m b o l
R e v i s i o n s
A p p r o v e d
R
US Army Corps
Rock Island District of Engineers
W E
K -0
-R
-0 X
X
X X
X X
X X
X
A B a u t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
S
L A
B
S
T O
R A
G E
Y A
R D
S L
A B
CONTRACTION JOINT
GREASE ONE
END OF BAR
BACKER ROD
JOINT SEALANT
SAWCUT
t o s h o r t d e s i g n a u t o s y t i m e a u t o u s e r n a m e
M I S
S I S
S I P
P I R
I V
E R
8 80 16
SCALE IN FEET
STORAGE YARD PLAN
E-110
B G
R
JW
B
S T
O R
A G
E Y
A R
D F
L O
O D
R E
P A
IR
S
S T
O R
A G
E Y
A R
D N
E W
W O
R K
P L
A N
D A
M
A S
S H
O W
N
K
R R
G L
A D
S T
O N
E I L
L O
C K
A N
D D
A M
N O
X
LEGEND & ABBREVIATIONS:
RGS
GENERAL NOTES:
KEY NOTES:
6.
7.
8.
9.
10.
EXISTING LIGHTING
JUNCTION BOX JB-L13
EXISTING POWER
JUNCTION
BOX JB-14
> SERVICE BRIDGE
ABUTMENT
A
EXISTING POWER
JUNCTION BOX JB-13
1.
2.
3.
4.
5.
X X
111096
EXISTING
STAIRS
MAINTAIN
EXISTING 50W HPS
LIGHT FIXTURES
NEW JB-L14
PIER
NO. 18
PIER
NO. 17
2�" RGS EXISTING
TO/FROM JB-L13
MAINTAIN EXISTING
CRANE RECEPTACLE
NEW CONCRETE SLAB
IN STORAGE YARD
> SERVICE BRIDGE
SEE DETAIL 3
ON SHEET E123
SEE DETAIL 2
ON SHEET E123
NEW CONCRETE
WINCH BASE
NEW CONCRETE WINCH BASE
ALL EQUIPMENT SHALL BE NEW UNLESS INDICATED OTHERWISE AND
SHALL BE PROVIDED AND INSTALLED BY THE CONTRACTOR.
INSTALL NEW CONDUITS EITHER UNDER THE UPSTREAM SIDE OF THE
SERVICE BRIDGE OR ROUTED WITH EXISTING CONDUITS ON THE
OUTSIDE OF THE SERVICE BRIDGE (OUTSIDE OF BRIDGE ALLOWED
OVER STORAGE YARD ONLY) .
PROVIDE AND INSTALL CONDUIT EXPANSION & CONTRACTION
FITTINGS ACROSS ALL BRIDGE EXPANSION JOINTS. PIER NO. 17
IS AN EXPANSION PIER FROM BOTH DIRECTIONS. EXISTING
CONDUIT EXPANSION JOINTS MAY OR MAY NOT BE INSTALLED IN
CORRECT LOCATIONS.
NO WELDING SHALL BE PERMITTED. ONLY APPROVED BEAM CLAMPS OR
BOLTED CONDUIT HANGERS SHALL BE USED.
DISSIMILAR METALS SHALL NOT BE INSTALLED IN DIRECT CONTACT
WITH EACH OTHER. ALL BRACKETS & HARDWARE SHALL BE
APPROVED BEFORE INSTALLATION.
NO GROUNDING CONDUCTORS OR CONDUITS SHALL PASS THROUGH OR
UNDER RAIL FOUNDATIONS NOR ANY OTHER STRUCTURAL EQUIPMENT
FOUNDATIONS.
ALL CONDUITS THAT PENETRATE THE NEW STORAGE YARD CONCRETE
SURFACE SHALL BE WRAPPED WITH PREMOLDED EXPANSION JOINT
FILLER.
FOR EQUIPMENT MOUNTING DETAILS, SEE SHEET E123.
1.
2.
3.
4.
5.
6.
7.
8.
NEW 2/0 AWG BARE STRANDED COPPER GROUNDING CONDUCTOR FROM GROUNDING
CONNECTION IN JUNCTION BOX JB-14 ON INTO EXISTING 1" RGS RISER CONDUIT TO
NEW GROUNDING ELECTRODES. CONDUIT SHALL PENETRATE NEW SLAB, BE PVC-TAPED, &
PRE-MOLDED EXPANSION JOINT FILLER. PROVIDE NEW INSULATED-THROAT GROUNDING
BUSHING ON END OF EXISTING CONDUIT TO TERMINATE GROUNDING CONDUIT. BOND
THE CONDUCTOR TO THE NEW GROUNDING BUSHING. SEE GENERAL NOTE 6.
THREE (3) NEW GROUNDING ELECTRODES. ALL GROUNDING CONNECTIONS (CONDUCTOR
TO ROD & WIRE TO WIRE) SHALL BE EXOTHERMIC WELD (CADWELD) CONNECTIONS.
EACH GROUNDING ELECTRODE (ROD) SHALL BE �" DIAMETER BY 10 FEET LONG
INSTALLED NOT MORE THAN 20 FEET APART IN AN EQUILATERAL TRIANGLE. EACH NEW
GROUNDING ROD SHALL BE INSTALLED IN A 12" X 12" X 12.75" DEEP IN-GROUND
PREFABRICATED, OPEN-BOTTOM, REINFORCED CONCRETE PULL BOX WITH 4-BOLT COVER
(BASIS OF DESIGN IS QUAZITE COMPOSOLITE 12" X 12" PC STYLE) FOR FUTURE
INSPECTION AND TESTING ACCESS. SEE ELECTRICAL DETAIL 1 ON SHEET E-121.
TWO NEW 3" TO 1�" RGS CONDUIT REDUCERS IN EXISTING CONDUIT BOX HUBS LEFT
INSTALLED AT JUNCTION BOX JB-14 AND INSTALL TWO NEW 1�" RGS CONDUITS FROM
JUNCTION BOX JB-14 TO A NEW 480VAC, 60 AMP, 3 POLE, HEAVY DUTY FUSED DOUBLE
POLE SAFETY SWITCH SIMILAR TO OR AS MANUFACTURED BY CUTLER-HAMMER.
ENCLOSURE SHALL BE NEMA 4X STAINLESS STEEL INSTALLED ON HANDRAIL ON SERVICE
BRIDGE (SEE MOUNTING DETAIL SHEET). PROVIDE AND INSTALL HOT-DIPPED
GALVANIZED MOUNTING BRACKET AND HARDWARE. PROVIDE AND INSTALL 60 AMP DUAL
ELEMENT FUSES AND PROVIDE ONE SPARE SET OF EQUAL FUSES TO CONTRACTING
OFFICER’S REPRESENTATIVE. INSTALL NEMA 4X NYLON DRAIN IN ENCLOSURE BOTTOM.
NEW CONDUIT FROM NEW DOUBLE THROW SAFETY SWITCH TO NEW EAST WINCH
DISCONNECT JUNCTION BOX. SEE KEY NOTE 5.
NEW 12"Hx10"Wx6"D NEMA 4X STAINLESS STEEL JUNCTION BOX WITH HINGED DOOR, BACK PANEL, AND COVERED POWER DISTRIBUTION BLOCK TO RUN & TAP 3 PHASE, #4
AWG CU CONDUCTORS.BASIS OF DESIGN FOR ENCLOSURE IS HOFFMAN TYPE CHNFSS AND
POWER BLOCKS BASIS IS MARATHON SPECIALTY PRODUCTS MODEL 1333554-CH. INSTALL
NEMA 4X NYLON DRAIN IN ENCLOSURE BOTTOM. PROVIDE & INSTALL HOT-DIPPED GALV.
MOUNTING BRACKET, AND NEMA 4X NYLON DRAIN & HARDWARE.
NEW 1�" RGS CONDUIT FROM NEW JUNCTION BOX TO NEW WINCH DISCONNECT SWITCHES ON
SERVICE BRIDGE HANDRAIL. NEW 480 VAC, 30 AMPERE FUSIBLE SAFETY SWITCH SHALL BE
RATED NOT LESS THAN 15 HP IN A NEMA 4X STAINLESS STEEL ENCLOSURE. SWITCHES SHALL
BE INSTALLED ON SERVICE BRIDGE ON DOWNSTREAM HANDRAILING BETWEEN THE HANDRAILS
WITH STAINLESS STEEL OR HOT-DIPPED GALVANIZED STEEL CUSTOM FABRICATED BRACKET.
ENCLOSURE SHALL BE PROVIDED WITH A NEMA 4 NYLON DRAIN FITTING INSTALLED IN THE
BOTTOM OF ENCLOSURE. PROVIDE AND INSTALL STAINLESS STEEL OR HOT-DIPPED
GALVANIZED MOUNTING BRACKET AND HARDWARE. PROVIDE AND INSTALL 480 VAC, 30 AMP
DUAL ELEMENT TRIP FUSES AND ONE SET OF SPARES FOR EACH WINCH DISCONNECT.
PROVIDE AND INSTALL NEW 1�" SPARE PVC-COATED RGS DIRECT-BURIED CONDUITS NOT LESS
THAN 18" DEEP FROM PIER NO. 17 TO EACH WINCH CONCRETE FOUNDATION. PROVIDE AND
INSTALL RGS CONDUIT RISER SECURED TO DOWNSTREAM FACE OF PIER 17 WITH TWO HOLE
CONDUIT STRAPS CONCRETE-ANCHORED TO PIER, EXTENDED TO +10 FEET ELEVATION ABOVE
THE FINISHED STORAGE YARD ELEVATION, AND WATERTIGHT PLUGGED AND SEALED. CONDUIT
RISER AT WINCH PAD STRUCTURAL SUPPORT SHALL BE FASTENED TO SUPPORT, TERMINATED,
AND WATERTIGHT PLUGGED AND SEALED AT +6 FEET ABOVE THE FINISHED STORAGE YARD
ELEVATION.
PROVIDE NEW STRUCTURAL STEEL SUPPORT ANCHOR-BOLTED TO CONCRETE WINCH
FOUNDATION FOR RECEPTACLE STRUCTURAL SUPPORT. SEE DETAIL 5 ON SHEET E-121.
PROVIDE AND INSTALL NEW 480 VAC, 60 AMP, 3 WIRE, 4 POLE, GROUNDED MOTOR SWITCH
RATED & HORSEPOWER RATED RECEPTACLE, 15HP RATED, NEMA 4X WATERTIGHT RECEPTACLE
WITH WATERTIGHT CAPS. PROVIDE NEW MATING PLUG WITH WATERTIGHT CAP ON NEW
PORTABLE FEEDER CORD. THIS RECEPTACLE SHALL CONNECT THE NEW PORTABLE CORD WITH
THE NEW FUSED DISCONNECT SWITCH ON SERVICE BRIDGE TO EXISTING WINCH CONTROLLER
WHEN WINCH IS INSTALLED IN STORAGE YARD. SEE KEY NOTE 10.
PROVIDE AND INSTALL NEW PORTABLE CABLE THAT WILL BE THE REMOVABLE POWER FEEDER
BETWEEN THE NEW DISCONNECT SWITCH ON THE SERVICE BRIDGE AND THE WINCH CONTROLLER
WHEN THE WINCH IS INSTALLED IN THE STORAGE YARD. THE PORTABLE CABLE SHALL BE 4
CONDUCTOR 10 AWG (INCLUDING GROUND WIRE), 600 VAC, TYPE SO OR SOW OR AS OTHERWISE
APPROVED. INSTALL MATING NEMA 4X SWITCH & HP RATED 480VAC, 60 AMP MALE PLUG WITH
WATERTIGHT ON EACH END OF THE PORTABLE CABLES. TWO IDENTICAL PORTABLE CABLE
ASSEMBLIES ARE REQUIRED. SEE KEY NOTE 11.
SEE GENERAL
NOTE 3
J C
Q /D
D
RIGID GALVANIZED STEEL (RGS) CONDUIT
EXPOSED RGS CONDUIT
BURIED PVC-COATED RGS CONDUIT
NEW 480 VAC, 60 A, 3-PHASE, 4-WIRE,15HP,
SWITCH & HP RATED WITH NEMA 4X NON-METALLIC
PIN & SLEEVE GROUNDED WATERPROOF RECEPTACLE.
PROVIDE WATERTIGHT CAPS FOR FEMALE
RECEPTACLE. PROVIDE MATING PLUGS WITH
WEATHERPROOF CAP.
JUNCTION BOX
GROUNDING ROD, �" DIA. X 10’ LONG,
IN PREFABRICATED CONCRETE PULLBOX
MOTOR DISCONNECT SAFETY SWITCH
EXISTING F4 FLOODLIGHT FIXTURE
RGS EXPANSION/CONTRACTION CONDUIT
FITTING WITH GROUNDING JUMPER. PIER
NO. 17 IS EXPANSION END OF STORAGE
YARD SERVICE BRIDGE SPANS. LOCATE
CONDUIT EXPANSION JOINTS FOR CORRECT
INSTALLATION.
NEW 120VAC, 20 AMP GFCI SPECIFICATION
GRADE RECEPTACLE PROVIDED AND INSTALLED
IN RELOCATED AND REUSED EXISTING CAST
METAL FD BOXES.
F4
F4
F4
F4
F4
INSTALL ONE NEW MATCHING POWER RECEPTACLE ON AND WIRING IN EACH EXISTING
WINCH CONTROLLER ENCLOSURES FOR CONNECTION TO THE NEW PORTABLE POWER CABLE
PLUG MALE CONNECTOR. INSTALL ONE NEW NEMA 4 RATED 120VAC RED EMERGENCY STOP
PUSH-PULL MAINTAINED CONTACT PUSHBUTTON SWITCH ON EACH EXISTING WINCH
CONTROLLER. WIRE NEW E-STOP TO EXISTING CONTROLS. PROVIDE LABEL, "EMERGENCY
STOP" FOR BOTH NEW E-STOP PUSHBUTTONS.
PROVIDE AND INSTALL NEW 12"H X 12"W X 6"D TO REPLACE EXISTING JUNCTION BOX.
NEW �" CONDUIT AND RECEPTACLE CIRCUIT CONDUCTORS SHALL BE ROUTED UP TO NEW
RECEPTACLES LOCATION ON SERVICE BRIDGE DOWNSTREAM HANDRAIL.
MAINTAIN EXISTING LIGHT FIXTURES.
NOT USED.
NOT USED.
INSTALL EXISTING FD OUTLET BOXES FROM STORAGE YARD AND INSTALL NEW 3 SINGLE
10 AWG IN �" RGS CONDUIT TO NEW OUTLET BOX FROM JB-L13 AND NEW JB-L14
RESPECTIVELY. PROVIDE NEW HOT-DIPPED GALVANIZED U-BOLT FASTENED BRACKETS TO
SECURE RECEPTACLES TO DOWNSTREAM HANDRAIL. LOCATIONS SHOWN APPROXIMATELY MAY
BE ADJUSTED TO BEST FIT HANDRAIL. INSTALL NEW 120VAC, 20AMP, SPECIFICATION
GRADE GFCI DUPLEX RECEPTACLES (4 TOTAL).
MAINTAIN EXISTING 3/4" RGS LIGHTING CONDUITS.
11.
12.
13.
14.
15.
16.
17.
A
B C D
E F G H
Sheet
Reference
Number:
S c a l e
D r a w n B y
A B C D E F G H
U .S
A
R M
Y E
N G
I N
E E
R D
I S
T R
I C
T
C O
R P
S O
F E
N G
I N
E E
R S
R O
C K
I S
L A
N D
I L
L I N
O I S
Sheet of XX
D e s i g n e d
B y
C h e c k e d
B y
R e v ie w e d B y
D a t e
P r o j e c t
C o d e
S o l i c i t a t i o n
N u m b e r
D e s c r i p t i o n
D a t e
S y m b o l
R e v i s i o n s
A p p r o v e d
R
US Army Corps
Rock Island District of Engineers
W E
K -0
-R
-0 X
X
X X
X X
X X
X
| 18600034 |
| 18600296 |
| 18600297 |
| 18600298 |
| 18600299 |
| 18600301 |
| 18600302 |
| 18600303 |
| 18600304 |
| 18600305 |
| 18600306 |
| 18600307 |
| 18600308 |
| 18600309 |
| 18600310 |
| 18600311 |
| 18600312 |
| 18600313 |
| 18600314 |
| 18600315 |
| 18600328 |
| 18600329 |
| 18600333 |
| 18600335 |
| Referenece Index.pdf |
| Sheet1 |
| Referenece Index.pdf |
| Sheet1 |
File details come from the government source that posted it. Updated .