This is a Scope of Work (SOW) for the fabrication and delivery of six wicket gate lock sets to Little Goose and Lower Granite hydroelectric dams in Washington. The contractor must provide one prototype wicket gate lock set for initial installation at Little Goose Dam, with subsequent fabrication and delivery of five additional lock sets contingent upon Government approval of the prototype installation. The lock mechanism consists of two pivoted, spring-loaded latch arms that engage a stop plate on the servomotor shaft, controlled by a solenoid-operated valve and activated by governor oil pressure supplied to a hydraulic cylinder. Each complete lock assembly includes fabricated components, hydraulic cylinders (double-acting, 2-inch bore, 1000 psi operating pressure, minimum 4-inch stroke), springs (extension type, 20 pounds per inch constant), piping and fittings (seamless stainless steel tubing per ASTM A269/A269M with 6:1 safety factor), solenoid valves (four-way, two-position, normally open, 125VDC coil rating, ASME B16.34 class 900), flow control valves, ball valves, check valves, limit switches (top pin plunger type, SPST snap action, 125VDC, 0.55 amps), junction boxes, terminal blocks, control switches, and various fasteners and hardware as detailed in the Bill of Materials. The contractor must supply three complete lock assembly sets per project location.

Submittals required prior to fabrication include Material Disposition Records, welder qualifications (per AWS D1.1/D1.1M), nondestructive testing personnel qualifications (per AWS D1.1/D1.1M and AWS QC1), ISO 9000 or equivalent quality management system certification, shop drawings (formatted to ANSI D standards and provided in AutoCAD format meeting A/E/C CAD Standards ERDC/ITL TR-19-7 and Graphics Standard ERDC/ITL TR-19-6, with accompanying Adobe PDF copies), and product data sheets for hydraulic cylinders, springs, pins, bushings, latches, clevis rod ends, fasteners, valves, and retaining rings. All fabrication must be performed to industry standards with components manufactured from specified materials (4140 steel, A36 steel, A229 steel, stainless steel, and fiber-reinforced PTFE composite bushings capable of handling 65 kips bearing force). Dimensional tolerances allow 1/32-inch variation for overall length of component members with both ends milled and 1/16-inch maximum deviation for members without milled ends. Upon fabrication completion, all components must be coated with wax-like rust inhibitor and protected during transport using polyethylene plastic wrap or sheeting suitable for highway speeds. The contractor is responsible for all repairs to road damage or debris contamination incurred during transport and storage at no additional Government cost.

View the file

Other files

File Type Posted
Technical Drawings_Draft.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAFT

SCOPE OF WORK FOR

THE SUPPLY OF SIX WICKET GATE LOCKS,

DELIVERED TO LITTLE GOOSE AND LOWER GRANITE DAM, WASHINGTON

1. GENERAL INFORMATION

1.1. Description of services and introduction: Provide all materials, tools, equipment, and labor necessary to fabricate and deliver one (1) prototype wicket gate lock and five (5) additional wicket gate lock sets following the successful install of the prototype, totaling six (6) complete wicket gate lock sets as defined in this Scope of Work. Perform all fabrication to industry standards.

1.2. Background: Generator Units 4-6 at Little Goose and Lower Granite powerhouses were originally equipped with automatic wicket gate locks. Throughout the years, the locks have been either modified or partially removed on some of the units in both project locations. The modifications to the mechanisms have caused them to not function as originally intended in addition to making their operation inconsistent from unit to unit.

1.3. Objectives: Manufacture and deliver six (6) complete sets of components for new wicket gate locks for

Units 4-6 at both Little Goose and Lower Granite dams. Phase the delivery between one (1) prototype wicket gate lock set to be delivered to Little Goose, and five (5) additional lock sets to be delivered to the dams after the Government confirms successful install of the prototype. The components for three complete lock assembly sets are required per project location. Installation will be performed by the

Government.

1.4. Scope: The lock mechanism design consists of two pivoted, spring-loaded latch arms which engage a stop plate located on the servomotor shaft. Governor oil pressure is supplied to the gate lock to activate a cylinder which releases the latches. The gate lock is controlled by a solenoid operated valve. The operating spring automatically engages the locking arms when the oil pressure in the cylinder is released and automatically disengage the locking arms when oil pressure is applied. Each lock has two limit switches per arm providing feedback when the lock is fully engaged and fully disengaged.

2. SUBMITTALS

2.1. Submit the following for Government review and approval in a schedule and order approved by the COR.

2.1.1. Material Disposition Record – Submit a copy of all purchase and mill orders, shop orders for materials and work orders, including all new orders placed by Contractors and old orders extended for each supplier. Furnish, at the time of submitting shop drawings, a list designating the material to be used for each item.

2.1.2. Qualification of Welders – Submit per paragraph 3.17.6

2.1.3. Qualification of Nondestructive Testing Personnel – Submit per paragraph 3.17.7

2.1.4. ISO Certification - Submit proof of ISO 9000 certification or equivalent quality management system certification for approval.

2.1.5. Shop Drawings – Submit per paragraph 3.18.

2.1.6. Hydraulic Cylinder Data – Submit all documentation on hydraulic cylinder selection including, but not limited to, operating pressure, stroke length, bore, mounting style, rod end thread, construction material, port size, port type, port positioning, and seal material.

2.1.7. Spring Data – Submit all documentation on spring selection including, but not limited to, spring constant, relaxed spring length, and maximum spring extension.

2.1.8. Pin Data – Submit cutsheets for all prefabricated pins.

2.1.9. Bushing Data – Submit all documentation for bushings indicating bushing material, maximum bearing strength, and major dimensions.

2.1.10. Latch Data – Submit cutsheets for the latches described in 3.15.

2.1.11. Clevis Rod End Data – Submit cutsheet data for the clevis rod end described in 3.14.

2.1.12. Fastener Data – Submit data for all bolts, nuts, and washers marked as requiring product data in the

Bill of Materials.

2.1.13. Valve Data – Submit cutsheet data for all valves described in the Scope of Work.

2.1.14. Retaining Ring Data – Submit cutsheet data for all retaining rings listed in the Bill of Materials.

2.2. Do not begin fabrication of components until the following submittals have been approved:

1. Shop Drawings

2. Hydraulic Cylinder Data

3. Spring Data

4. Pin Data

5. Bushing Data

6. Latch Data

7. Clevis Rod End Data

8. Retaining Ring Data

3. PERFORMANCE SPECIFICATIONS

3.1. Provide all components for a total of six wicket gate lock sets as per contract drawings and as detailed in this document. These include but are not limited to the following:

3.1.1. Gate lock fabricated components.

3.1.2. Bolts and screws for all applicable connections.

3.1.3. Hydraulic cylinder for each lock assembly.

3.1.4. Gate lock solenoid valve with manual override.

3.1.5. ½ in adjustable hydraulic oil flow control valve.

3.1.6. ½ in lockable manual ball valve.

3.1.7. ½ in automatic three-way valve.

3.1.8. Limit switches.

3.1.9. Control switches.

Bill of Materials – Wicket Gate Lock Sets

Item

No.

Description Material Little

Goose

Lower

Granite

Product

Data submittal required

Shop

Drawing submittal required

1 Existing Wicket Gate Lock

Housing steel, carbon 0 0

2 Existing Servomotor Shaft steel, carbon 0 0

3 Latch Arm 4140 Steel 6 6 x

4 Pin Bottom Plate A36 Steel 6 6 x

5 Latch Arm Tip 4140 Steel 6 6 x

6 Collar Spacer 4140 Steel 6 6 x

7 Actuation Box Baseplate A36 Steel 3 3 x

8 Actuation Arm A36 Steel 6 6 x

9 Center Link A36 Steel 3 3 x

10 Spring Mount Link A36 Steel 6 6 x

11 Spring Mount A36 Steel 6 6 x

12 Spring A229 Steel 3 3 x x

13 Link Pin zinc plated carbon steel

12 12 x

14a 1/32" shim 4140 Steel 12 12 x

14b 1/16" shim 4140 Steel 18 18 x

14c 1/8" Shim 4140 Steel 12 12 x

14d 1/4" Shim 4140 Steel 6 6 x

15 Hydraulic Cylinder n/a 3 3 x

16 Link Pin Bushing Short

Piece

Fiber

Reinforced

PTFE

Composite

24 24 x x

17 Spring Mount Bushing Fiber

Reinforced

PTFE

Composite

6 6 x x

18 Actuation Link A36 Steel 6 6 x

19 Limit Switch Per Mfr 14 14 x

20 Left Latch Pin Heat Treated

4340 Steel

3 3 x

21 Right Latch Pin Heat Treated

4340 Steel

3 3 x

22 Latch Pin Bushing Fiber

Reinforced

PTFE

Composite

12 12 x x

23 Lockout Fork Prehardened

4140 steel

3 3 x

24 Latch Arm Dowel 4140 Steel 3 3 x

25 Locking Anchor Prehardened

4140 steel

6 6 x

26 Actuation Box Cover (Left) A36 steel 3 3 x

27 Actuation Box Cover

(Right)

A36 steel 3 3 x

28 Latch Stainless Steel 12 12 x

29 Link Pin Bushing Long

Piece

Fiber

Reinforced

PTFE

Composite

12 12 x x

30 Clevis Rod End Stainless Steel 3 3 x

31 Hydraulic Cylinder Spacer A36 Steel 3 3 x

32 Actuation Arm Pin 4140 Steel 6 6 x

33 NOT USED N/A

34 Hydraulic Clevis Pin zinc plated carbon steel

6 6 x

35 Limit Switch Spacer A36 Steel 12 12 x

36 1-8 UNC x 3" Grade 8 Bolt zinc plated carbon steel

6 6

37 1/4-28 UNF x 1" Grade 8

Bolt zinc plated carbon steel

12 12

38 1/2-13 UNC x 1" Grade 8

Bolt zinc plated carbon steel

12 12

39 5/8-10 UNC x 1" Grade 8

Bolt zinc plated carbon steel

12 12

40 1/2-13 UNC x 1.25" Grade 8

Bolt zinc plated carbon steel

6 6

41 1/2-10 UNC x 1.75" Grade 8

Bolt zinc plated carbon steel

24 24

42 1 1/2-6 UNC x 1.5" Grade 8

Bolt zinc plated carbon steel

6 6

43 1/2-13 UNC x 2.75" Grade 8

Bolt zinc plated carbon steel

12 12

44 1/2-13 UNC x 4" Grade 8

Bolt with 2.875" shoulder zinc plated carbon steel

12 12

45 Latch Bolts - size as needed with latches zinc plated carbon steel as needed as needed x

46 Cylinder Bolts - size as needed with Cylinders zinc plated carbon steel as needed as needed x

47 Limit Switch Bolts - Size as needed with Limit Switches zinc plated carbon steel as needed as needed x

48 1/2" washer zinc plated carbon steel

36 36

49 5/8" washer zinc plated carbon steel

12 12

50 1" washer zinc plated carbon steel

6 6

51 1-3/4" washer zinc plated carbon steel

6 6

52 Latch washer - size to match Latch Bolts zinc plated carbon steel

As needed

As needed x

53 Cylinder Washer - Size to match Cylinder Bolts zinc plated carbon steel

As needed

As needed x

54 Limit Switch Washer - Size as needed to match limit switch bolts zinc plated carbon steel

As needed

As needed x

55 1-8 UNC Nut zinc plated carbon steel

6 6 x

56 Latch Nut - size as needed for latch bolts zinc plated carbon steel as needed as needed x

57 Cylinder Nut - Size as needed for cylinder bolts zinc plated carbon steel as needed as needed x

58 Limit switch nut - size as needed for limit switch bolt zinc plated carbon steel as needed as needed x

59 Hoist ring – ½-13 UNC thread

Stainless Steel 8 8 x

60 7/8" external retaining ring Phosphate-coated carbon steel

12 12 x

61 3/4" external retaining ring Phosphate-coated carbon steel

3 3 x

62 1/2" external retaining ring Phosphate-coated carbon steel

12 12 x

63 1-3/4" external retaining ring

Phosphate-coated carbon steel

6 6

64 Control Switch Per Mfr 3 3 x

65 Solenoid Valve Stainless Steel 3 3 x

66 ½” Automatic Three-Way

Valve

Stainless Steel 3 3 x

67 ½” Check Valve Stainless Steel 3 3 x

68 ½” Lockable Ball Valve Stainless Steel 15 15 x

69 ½” Flow Control Valve Stainless Steel 3 3 x

70 Junction Box Per Mfr 3 3

71 Terminal Block Per Mfr 48 48

72 Carrier Rail; 35 X 7.5 Mm steel, carbon 3 Ft 3 Ft

73 1/2"x20’ straight tubing Stainless Steel 3 20

74 Swagelok Tube Fitting, Union Elbow, 1/2 in. Tube

OD

Stainless Steel 0 12 x

75 Swagelok Tube Fitting, Union Tee, 1/2 in. Tube OD

Stainless Steel 0 12 x

76 Swagelok Tube Fitting, Union Straight, 1/2 in. Tube

OD

Stainless Steel 60 60 x

77 Swagelok Tube Fitting, Dielectric Union Straight, 1/2 in. Tube OD

Stainless Steel 6 6 x

3.2. GATE LOCK FABRICATED COMPONENTS

This section provides additional detail for the requirements for the machined components of the gate lock.

3.2.1. Provide all components out of the materials listed in the Bill of Materials, or of equal material properties as approved by the COR. All other components must be steel with a minimum yield strength of 30ksi.

3.2.2. Manufacture per approved shop drawings, coordinate with designer of record for any discrepancies or changes required.

3.2.3. The overall dimensions of an assembled unit must be within the tolerances indicated on the drawings or as specified for the item of work. Where tolerances are not specified in other sections of these specifications or shown, a variation of 1/32 inch is permissible in the overall length of component members with both ends milled and component members without milled ends must not deviate from the dimensions shown by not more than 1/16 inch.

3.2.4. All bushings must be made of a self-lubricating, fiber reinforced polytetrafluoroethylene (PTFE) composite with a minimum strength capable of handling 65 kips of bearing force.

3.3. HYDRAULIC CYLINDER

This section details the requirements for the hydraulic cylinder to operate the gate lock.

3.3.1. Cylinder must be double acting 2 inch bore, and suitable for use with an ISO 100 Turbine Oil.

3.3.2. Operating oil pressure to the cylinder: 1000 psi.

3.3.3. Minimum required stroke length: 4 inches.

3.3.4. Max cylinder length: 12 inches

3.3.5. Mounting style: bottom flange per contract drawings

3.3.6. Rod end: Standard UNF male threads, match with threads of stainless-steel clevis rod end.

3.3.7. Port size and type: ½ inch ORB

3.4. EXTENSION SPRING

3.4.1. The spring must be of an extension type with a spring constant of 20 pounds per inch.

3.4.2. The spring must have an unstressed length of 14 inches, with an allowable extension of at least 10 inches.

3.5. PIPING AND FITTINGS

3.5.1. Piping and Tubing

1. Provide seamless stainless steel tubing conforming to ASTM A269/A269M. Tubing wall thickness must be such that a 6:1 safety factor is maintained at design pressure of 1000 psi. Provide tubing in lengths and diameters as called for in the Bill of Materials.

3.5.2. Fittings

1. Furnish tube fittings that are made from 316 stainless steel and have a two-ferrule design that separates the sealing and tube gripping functions and does not exhibit torque on the tubing during installation.

2. Furnish the sizes, types, and quantity of fittings listen in the Bill of Materials.

3.6. GATE LOCK SOLENOID VALVES

3.6.1. Solenoid valves must be four-way, two-position and normally open, with 1/2 inch ports compatible with Swagelok fittings. Valves must be constructed of either stainless-steel or equivalent material to prevent galvanic corrosion with the stainless-steel governor tubing. Valves must be ASME B16.34 class 900 or stronger. Coils must be rated to operate at 125VDC. Valves must conform to ASME

B16.34 and ASME B16.10. The valve enclosure must be rated to NEMA 13.

3.7. HYDRAULIC FLOW CONTROL VALVE

3.7.1. Valves must be stainless-steel material to prevent galvanic corrosion with the stainless-steel governor tubing and threaded in accordance with ASME B1.20.1. Valve must be an orifice flow control valve and flow rate must be manually adjustable in the field and able to be set in position. Valves must be

ASME B16.34 class 900 or stronger. Valves must conform to ASME B16.34 and ASME B16.10.

The valves must have ½ inch ports compatible with Swagelok fittings.

3.8. BALL VALVES

3.8.1. Valves must be stainless steel or equivalent material to prevent galvanic corrosion with the stainless-steel governor tubing and threaded in accordance with ASME B1.20.1. Valves must have ½-inch ports to be compatible with governor tubing with Swagelok fittings. Valves must have the ability to be manually locked out with a padlock. Valves must be ASME B16.34 class 900 or stronger. Valves must conform to ASME B16.34 and ASME B16.10.

3.9. CHECK VALVES

3.9.1. Check valves must be designed for horizontal installation with ½-inch ports compatible with

Swagelok fittings. Valves must be brass or equivalent material to prevent galvanic corrosion with the stainless-steel governor tubing threaded in accordance with ASME B1.20.1. Valves must be ASME

B16.34 class 900 or stronger. Valves must conform to ASME B16.34 and ASME B16.10.

3.10. LIMIT SWITCHES

Provide 4 identical limit switches per gate lock, as well as 2 additional spare switches per plant. One switch on each side must indicate lock is fully closed and one limit switch on each side must indicate gate lock is fully open. Switches will be wired by the Government in the field.

3.10.1. Limit switches must be of a top pin plunger type appropriate for horizontal use. Each switch must be

SPST snap action with contacts rated for 125VDC and 0.55 amps.

3.10.2. Limit switch spacer must be designed so that the limit switch plunger will be at the height above the baseplate as described in the contract drawings.

3.10.3. Limit switches must have NEMA 13 rated enclosures.

3.11. JUNCTION BOX

Junction box must be ANSI grey NEMA type 12, Dimension must be 12”x10”x4”.

3.12. TERMINAL BLOCKS

Sixteen (16) terminal blocks must be mounted on DIN rail in each junction box. Terminal blocks must be heavy duty switch type, screw clamp, push turn (1/4) knob type switching, rated at 600V and 20A minimum, accept wire sizes from #22 to #8, DIN rail mountable.

3.13. CONTROL SWITCH

Furnish 3, 2-position rotary control switches for each powerhouse. Switches must have black pistol grip, maintained action. Label the nameplate OFF and AUTO. Off position must be at 0 degrees and AUTO position must be at 45 degrees. Contacts must be rated for 125VDC at 3 amps.

3.14. CLEVIS ROD END

3.14.1. Clevis rod end must be made of stainless-steel to prevent corrosion with the hydraulic cylinder piston rod.

3.14.2. The clevis rod end must be sized for a hydraulic cylinder with a 2-inch bore

3.14.3. Size the clevis for a pin diameter of ¾-inches.

3.14.4. The jaw opening must be 1-1/4 inches.

3.15. LATCH

3.15.1. Latches must be capable of mounting to baseplate and cover with bolts using the manufacturer’s recommended method of fastening.

3.15.2. Each latch must be operable by hand without the use of tools.

3.15.3. The latches must be corner mounted draw latches.

3.16. SHIMS

3.16.1. Provide shims at thicknesses ranging from 1/4 inches to 1/32 inches as called out in the Contract

Drawings.

3.17. SWIVEL HOIST RINGS

3.17.1. Provide hoist rings suitable for material handling

3.17.2. Each hoist ring must utilize a threaded connection as listed in the Bill of Materials in this SOW.

3.17.3. The 1/2-inch thread diameter hoist ring must be capable of handling loads of up to 400 lbs.

3.17.4. The exposed threads of the hoist ring bolt must not exceed 15/16 inches in length.

3.17.5. Ensure hoist rings are capable of both pivoting and swiveling when loaded.

3.18. SHOP DRAWINGS

3.18.1. DEFINITIONS

1. Contract Drawings

Contract drawings are the set of Design Drawings furnished by the Government for this contract. Contract Drawings form a part of the legal contract between the Contractor and

Government, and do NOT include FIO's or Resource Drawings.

2. Fabrication Drawings

Submit fabrication drawings for review and approval by the Contracting Officer prior to beginning fabrication of the gate lock components. Submit all drawings submitted to the

Contracting Officer in accordance with paragraph "Format for SD-02 Shop Drawings".

3. FINAL SHOP DRAWINGS

Upon completion of the work under this contract, submit for review and approval by the

Contracting Officer, a copy, in ADOBE .pdf, of the final SHOP DRAWINGS. Submit all drawings submitted to the Contracting Officer in accordance with paragraph "Format for SD-02 Shop Drawings". Show all changes and revisions in the drawings, including any shop changes, made up to the time that the work is completed and accepted.

3.18.2. CAD FILE REQUIREMENTS

1. The following applies to all CAD File submittals, unless otherwise noted:

a. Furnish CAD files in the latest version of AutoCAD, for all CAD Files submitted by the Contractor in performance of this contract.

b. Meet A/E/C CAD and Graphic Standards in all CAD Files unless otherwise noted, as follows:

c. Compliant with the A/E/C CAD Standard ERDC/ITL TR-19-7, A/E/C Graphics

Standard ERDC/ITL TR-19-6.

d. CAD Files must have presentation graphics which can be edited by AutoCAD software (with the exception of photographs). Presentation graphics typically consist of drawing elements such as lines, arcs, shapes, text, and their attributes (e.g., color, width, line style)

e. In addition to CAD files, submit an ADOBE .pdf of each CAD File. The pdfs and the

CAD files must be identical.

f. Submit files using the DoD SAFE (Secure Access File Exchange) website as directed by the Contracting Officer.

g. The shop drawings are not required to comply with A/E/C CAD and Graphic

Standards.

h. Furnish a complete set of Shop Drawings in AutoCAD format for all Shop drawings produced by the Contractor in performance of this contract. Submittal of concrete placement drawings, concrete reinforcement drawings, and concrete formwork drawings are not required.

2. Furnish an index drawing for all Shop drawing submittal sets. Include the following for each

Shop drawing in the Index:

a. Sheet Number.

b. File Number.

c. Drawing Title.

d. CAD File Name.

e. Furnish an electronic spread sheet of the index to include all information specified in paragraph "Format for SD-02 Shop Drawings" that is compatible with Microsoft

Excel.

3.18.3. FORMAT FOR SD-02 SHOP DRAWINGS

1. All shop drawings prepared by the Contractor for this contract shall be formatted to American

National Standards Institute (ANSI D).

a. All shop drawings shall have a title block prepared by the Contractor independent of any Contract Drawing. Include a revision block.

b. Title block shall include project title, sheet description, sheet number, contract number and issue date.

c. Revision block shall contain revision mark, revision description, date of revision.

d. Each Sheet shall have a unique number.

e. Each sheet shall have the Contractor Firm name on it.

2. CAD requirements for Shop Drawings include the following:

a. CAD file(s) meeting requirements of paragraph "CAD File Requirements".

b. An Adobe .pdf copy of the corresponding CAD file(s). The pdfs and CAD files shall be identical.

c. Shop drawing format does not need to comply with A/E/C CAD and Graphic

Standards.

3.18.4. SHOP DRAWING SUBMITTALS

Shop Drawing Submittals are required as follows:

1. As shown and specified in the plans and specifications during design and Construction.

2. As specified

3.18.5. FABRICATON DRAWINGS

1. Prior to the start of fabrication, submit all fabrication drawings for review and approval. Submit the drawings in ADOBE .pdf format.

3.18.6. FINAL AS-BUILT DRAWINGS

1. At the completion of the work, submit a copy of the Final As-Built Drawings, after all As-Built conditions from the working as-built drawings have been incorporated in the CAD drawings.

Submit in ADOBE .pdf format.

2. In preparation for submitting Record Drawings, once the Final As-Built Drawings are approved, populate the CAD File Status Field with "Record Drawing" to comply with the A/E/C Graphic

Standards ERDC/ITL TR-19-6, Border Sheet Status Section.

3.17. QUALIFICATIONS AND CERTIFICATES

3.17.6. Qualification of Welders

1. Welding operators, welders, and tack welders must be qualified in accordance with Section 4, Part C or

AWS D1.1/D1.1M. Provide the certifications of the welders and welding operators by an independent testing company. The certification must include the name(s) of the welders and welding operators, the date of the qualification code, and the process under which they are qualified. Prior qualification may be accepted provided the welder has performed satisfactory work within the preceding three months under the code for which qualified, and certification of prior qualification from an independent testing company is furnished.

3.17.7. Qualification of Nondestructive Testing Personnel

1. Weld inspectors and nondestructive testing personnel must be qualified in accordance with AWS

D1.1/D1.1M and AWS QC1. Submit certifications for the inspectors by an independent company.

The certifications must include the name(s) of the weld inspectors and nondestructive testing personnel, the date of the qualification code, and the process under which they are qualified. Prior qualification may be accepted provided the welder has performed satisfactory work within the preceding three months under the code for which qualified, and certification of prior qualification from an independent testing company is furnished.

3.17.8. ISO Certification

1. Submit proof of ISO 9000 certification or equivalent quality management system certification for approval.

3.18. SHIPMENT OF FABRICATED COMPONENTS

3.18.6. Phase the fabrication and shipping of the components as described in this Section:

1. Fabricate and ship one (1) wicket gate lock set to be used for a prototype installation at Little Goose

Dam. Treat this shipment and subsequent installation by the Government as a hold point and do not proceed to fabricate or ship any of the remaining balance of components until approved by the

Government. Coordinate with the Contracting Officer to establish a schedule for the plant installation of the prototype.

2. Fabricate and ship five (5) wicket gate lock sets after receiving Government approval to proceed from the prototype hold point.

3.18.7. Upon completion of fabrication, prepare the components for delivery to the Government’s facilities.

3.18.8. Group all parts listed in the Parts List located on M-101 of the drawings together such that all components for a single wicket gate lock unit can be found in a single shipment.

3.18.9. Coat all fabricated components in a wax-like rust inhibitor prior to shipping.

3.18.10. Protect all components from weather, highway elements, damage, abuse, and loss during transport and storage, utilizing appropriate dunnage, softeners, strap guards, tie-down protectors, wear pads, and protective covers. A suitable temporary protective barrier over all surfaces, bearings, components, and equipment is required to prevent damage from loose roadway gravel, debris, and other transport hazards. This barrier must consist of polyethylene plastic wrap, sheeting, or similar materials commonly used for protection from road debris during highway transport, creating a physical barrier over all exposed exterior surfaces, bearings, components, and equipment. The plastic wrap, sheeting, or similar material must be suitable for highway speeds and prevent tearing or detachment during transport. The sheeting must possess adequate thickness and tensile strength to withstand the stresses of highway transport and be UV stabilized to prevent degradation from sunlight. The Contractor is required to ensure that the selected plastic wrap or sheeting and attachment method is suitable for highway transport and will not damage protected surfaces. The selected material and attachment method must be non-abrasive to the component surfaces and prevent chemical reactions or residue.

3.18.11. The Contractor is responsible for cleaning and repairing any road rash, debris contamination, or other damages incurred during transport or storage in accordance with these specifications at no additional cost to the Government.

(End of Statement of Work)