W912DW21R0023_Plans - 2 of 2.PDF
PDF 10 MB Posted
- Solicitation number
- W912DW-21-R-0023
About this file
This notice provides details of an anticipated federal contract solicitation for construction services. The United States Army Corps of Engineers Seattle District plans to solicit and award a firm-fixed price contract for the construction of a Retail Fuel Facility at Joint Base Lewis-McChord in Washington state. The scope of work involves constructing a controls building, fuel storage tanks, fueling dispensers and an operations building to support installation and transient vehicle fueling. The fuel storage tanks will contain kerosene, diesel and gasoline and include associated piping, pumps and equipment. The construction magnitude is estimated between $10-25 million. The solicitation is anticipated to be posted on March 22, 2021 on SAM.gov and will only be available electronically. The evaluation will use LPTA procedures to select the lowest priced technically acceptable offer.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
J
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
B
ADVERTISEMENT
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
GENERAL STRUCTURAL NOTES:
DECKING AND SHALL NOT BE REMOVED WITHOUT PERMISSION FROM THE DESIGNER OF RECORD.
6. BRACING FOR THE COLD FORMED FRAMING SHALL BE INSTALLED PRIOR TO THE INSTALLATION OF
FURNISHED BY THE CONTRACTOR .
5. ALL COLD FORMED FRAMING, BRACING, CONNECTIONS, AND ACCESSORIES SHALL BE DESIGNED AND
FURNISHED BY THE COLD FORMED DESIGNER/SUPPLIER.
4. CONNECTIONS AND BEARING MATERIAL REQUIRED BUT NOT CALLED OUT, SHALL BE DESIGNED AND
AND SUBMITTED FOR REVIEW AND APPROVAL.
3. COLD FORMED STEEL DESIGN SHALL BE SIGNED AND SEALED BY A LISCENSED STRUCTURAL ENGINEER
1926.
2. COLD FORMED STEEL JOISTS SHALL BE ERECTED IN ACCORDANCE WITH OSHA REGUALTION 29 CFR PART
S-100 AND ALL OTHER APPLICABLE STANDARDS.
1. DESIGN, FABRICATION, AND ERECTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITION OF AISI
G. COLD FORMED FRAMING:
IN THE SECTION & DETAILS (UNO).
3. THE WORKING LINES (W.L.) OF ALL STRUCTURAL STEEL SHALL COINCIDE AT A COMMON POINT AS SHOWN
TO AWS D1.3 WELDING ELECTRODES SHALL BE E70XX.
2. WELDING SHALL CONFORM TO AWS D1.1 EXCEPT THAT WELDING FOR THE STEEL DECK SHALL CONFORM
1. MINIMUM BOLT SPACING SHALL BE 3" (UNO). MINIMUM EDGE DISTANCE SHALL BE 1 1/4".
F. STRUCTURAL STEEL (GENERAL):
9. ALL LINTELS SHALL HAVE A MINIMUM BEARING OF 8 INCHES EACH END.
8. PROVIDE LINTELS OVER ALL OPENINGS AND RECESSES IN MASONRY WALLS.
7. PROVIDE CONTINUOUS WIRE LATH GROUT BARRIERS BELOW BOND BEAMS.
6. SPLICE MASONRY WALL REINFORCING AS SHOWN ON S-003.
MASONRY AS SHOWN ON S-003 UNLESS NOTED OTHERWISE.
5. PROVIDE LADDER TYPE JOINT REINFORCING AT 16" ON CENTER VERTICAL SPACING IN ALL CONCRETE
JAMBS, AND SIDE OF EXPANSION OR CONTROL JOINTS UNLESS NOTED OTHERWISE.
ADDITIONAL REINFORCING SHALL BE AT CORNER CELLS, INTERSECTIONS, WALL ENDS, DOOR AND WINDOW
4. PROVIDE CONTINUOUS FULL HEIGHT VERTICAL REINFORCING IN CENTER OF GROUT AT CENTER OF WALL.
3. MAXIMUM GROUT LIFT WITHOUT CLEANOUTS SHALL BE 4'-0" IN BLOCK WALLS.
2. LAY MASONRY UNITS IN RUNNING BOND.
SPECIFICATIONS FOR MASONRY CONSTRUCTION (TMS 402/602-16).
1. FURNISH AND CONSTRUCT MASONRY IN ACCORDANCE WITH THE REQUIREMENTS OF THE
E. MASONRY:
PLACEMENT AS MASS CONCRETE.
12. FOR CONCRETE PLACEMENTS OF 3'-0" OR MORE IN THICKNESS, THE CONTRACTOR SHALL TREAT THE
STRUCTURES" (ACI 315 - LATEST EDITION) EXCEPT AS OTHERWISE DETAILED OR SPECIFIED.
ACCORDANCE WITH THE "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE
11. REINFORCEMENT SHALL BE BENT COLD, AND DETAILED, FABRICATED, AND HELD IN PLACE IN
HOOK IS SHOWN, UNLESS DETAILED OTHERWISE.
AND LAP SPLICED ONLY IN REGIONS OF LOW STRESS. ALL BARS SHALL HAVE A STANDARD HOOK WHERE A
10. ALL REINFORCING IN SLABS AND FOUNDATIONS SHALL BE CONTINUOUS UNLESS DETAILED OTHERWISE
O.C. AT SLAB MID-DEPTH ON 6" GRANULAR FILL WITH VAPOR BARRIER.
9. UNLESS NOTED OTHERWISE, SLABS ON GRADE SHALL BE 6" CONCRETE REINFORCED WITH #4 BARS @ 12"
OTHERWISE.
SPACING OF 24x THE SLAB THICKNESS. MAXIMUM ASPECT RATIO SHALL BE 1.25 TO 1.0 UNLESS NOTED
JOINTS SHALL BE PLACED AT COLUMN-LINE INTERSECTIONS AND AS NECESSARY TO NOT EXCEED A
8. CONTROL JOINTS IN SLAB-ON-GRADE SHALL BE PLACED AS SHOWN. WHERE NOT SHOWN, CONTROL
15 LOCAL VALUES OF LEVELNESS, F(L)
21 LOCAL VALUES OF FLATNESS, F(F)
25 SPECIFIED OVERALL VALUES OF LEVELNESS, F(L)
35 SPECIFIED OVERALL VALUES OF FLATNESS, F(F)
FOLLOWING SURFACE REQUIREMENTS:
CONCRETE SURFACES. DO NOT WET CONCRETE SURFACES. SLABS-ON-GRADE SHALL MEET THE
302.1R RECOMMENDATIONS FOR SCREEDING, RESTRAIGHTENING, AND FINISHING OPERATIONS FOR
7. FINISH SLABS-ON-GRADES PER THE FOLLOWING CRITERIA ACCORDING TO ASTM E1155. COMPLY WITH ACI
ELEVATION, AND POSITION INDICATED WITHIN TOLERANCE LIMITS OF ACI 117.
6. CONSTRUCT FORMWORK SO CONCRETE MEMBERS AND STRUCTURES ARE OF SIZE, SHAPE, ALIGNMENT, CONTRACTING OFFICER.
5. DO NOT PLACE PIPES, DUCTS, OR CHASES IN STRUCTURAL CONCRETE WITHOUT APPROVAL OF THE
AROUND UNDERFLOOR DUCTS AND OTHER ITEMS EMBEDDED IN THE SLAB.
4. MECHANICALLY VIBRATE CONCRETE, EXCEPT THAT SLABS-ON-GRADE ONLY NEED TO BE VIBRATED
COVER REQUIREMENTS ON SHEET S-002. FLOATING REINFORCING IS NOT ALLOWED.
3. REINFORCING SHALL BE ACCURATELY PLACED BEFORE PLACING CONCRETE AND SHALL MEET CONCRETE
2. PROVIDE CORNER BARS IN FOOTINGS THE SAME SIZE AND NUMBER AS THE CONTINUOUS REINFORCING.
1. FOR REINFORCEMENT DEVELOPMENT AND SPLICE LENGTHS SEE TABLES ON SHEET S-002.
D. CONCRETE:
REQUIRED BY THE GEOTECHNICAL ENGINEER.
AS DETERMINED BY THE OWNER'S GEOTECHNICAL ENGINEER, SHALL BE REMOVED AND REPLACED AS
BACKFILL/GRANULAR FILL. ANY UNACCEPTABLE UNDISTURBED VIRGIN SOIL OR BACKFILL/GRANULAR FILL,
6. ALL SLABS ON GRADE SHALL BEAR ON UNDISTURBED VIRGIN SOIL OR PROPERLY COMPACTED
CAPACITY SHALL BE BROUGHT TO THE ATTENTION OF THE CONTRACTING OFFICER.
CONTRACTING OFFICER PRIOR TO PLACING CONCRETE. ANY SUBGRADES NOT MEETING THE STATED
INSPECTED AND APPROVED BY THE CONTRACTOR'S GEOTECHNICAL ENGINEER AND INSPECTED BY THE
AND ENSURE THEY MEET THE STATED ALLOWABLE SOIL BEARING CAPACITY. SUBGRADES SHALL BE
5. THE CONTRACTOR SHALL HIRE A GEOTECHNICAL ENGINEER TO INSPECT ALL FOUNDATION SUBGRADES
TO AVOID EXCESSIVE STRESSES AND TO HOLD STRUCTURAL ELEMENTS IN PLACE DURING CONSTRUCTION.
WITH APPROPRIATE TRADES. PROVIDE ALL TEMPORARY BRACING, SHORING, GUYING, OR OTHER MEANS
2. ESTABLISH AND VERIFY ALL OPENINGS AND INSERTS FOR MECHANICAL, ELECTRICAL, AND PLUMBING
OFFICER OF ANY DISCREPANCIES OR INCONSISTENCIES.
1. VERIFY ALL DIMENSIONS AND CONDITIONS PRIOR TO STARTING WORK. NOTIFY THE CONTRACTING
J. OTHER:
7. SEE SPECIFICATION SECTION 01 45 35 SPECIAL INSPECTIONS FOR ADDITIONAL REQUIREMENTS.
STANDARD FOR THAT WELD (AWS D1.1, AWS D1.2, OR AWS D1.3, OR OTHER).
6. ALL WELDS SHALL BE VISUALLY INSPECTED PER THE MOST CURRENT VERSION OF THE APPLICABLE AWS
1705.6SOILS
1705.4MASONRY CONSTRUCTION
1705.3CONCRETE CONSTRUCTION
1705.2STEEL CONSTRUCTION
01 45 35 SPECIAL INSPECTIONS AND THE FOLLOWING SECTIONS IN IBC 2018:
5. SPECIFIC MATERIALS SHALL HAVE SPECIAL INSPECTIONS IN ACCORDANCE WITH SPECIFICATION SECTION
4. INCLUDE SPECIAL INSPECTION REQUIREMENTS IN THE CONTRACTOR'S QUALITY CONTROL (CQC) PLAN.
REQUIRING SPECIAL INSPECTION IS IN COMPLIANCE.
SPECIAL INSPECTOR IS ON SITE AT ALL TIME INTERVALS NECESSARY TO CONFIRM THAT ALL WORK
OBSERVING THE WORK REQUIRING SPECIAL INSPECTION. PERIODIC SPECIAL INSPECTION MEANS THAT THE
3. CONTINUOUS SPECIAL INSPECTION MEANS THAT THE SPECIAL INSPECTOR IS ON THE SITE AT ALL TIMES
OF COMPLIANCE.
PREFABRICATION IF THE APPROVED AGENCY CERTIFIES THE CONSTRUCTION AND FURNISHES EVIDENCE
CONSTRUCTION TOOK PLACE ON SITE. CONTINUOUS INSPECTION WILL NOT BE REQUIRED DURING
2. INSPECTION OF PREFABRICATED CONSTRUCTION SHALL BE THE SAME AS IF THE MATERIAL USED IN THE
1704.2.5.1.
1. FABRICATORS PER SECTION 1704.2.5 WITH THE EXCEPTION OF APPROVED FABRICATORS PER SECTION
I. SPECIAL INSPECTIONS (IBC 2018):
REQUIREMENTS.
5. SEE SHEET SF101 AND SS403 FOR MINIMUM STEEL DECK PROPERTIES AND FOR MINIMUM FASTENING
OF ROOF CURBS TO STIFFEN METAL DECK EDGES. SEE SHEET SF501
4. PROVIDE L3X3X1/4 ANGLE FRAMING AROUND ALL ROOF PENETRATIONS AND AS REQUIRED FOR SUPPORT
SURFACE FOR APPLICATION OF INSULATION AND ROOFING.
AND VALLEY PLATES, WELDING WASHERS AND OTHER ACCESSORIES REQUIRED TO PROVIDE A FINISHED
3. THE DECK MANUFACTURER SHALL FURNISH CLOSURE PLATES, SUMP PANS AND DRAIN PLATES, RIDGE
2. PROVIDE ALL NECESSARY DETAILS SUCH AS RIDGE OR VALLEY SPLICE PLATES.
MEMBER OF THE STEEL DECK INSTITUTE.
1. MATERIAL, DESIGN, MANUFACTURE, AND INSTALLATION OF METAL DECKING SHALL BE FURNISHED BY A
H. STEEL DECK:
PROVIDE A MINIMUM OF 2'-0" OF GRADE ABOVE THE BOTTOM OF ALL FOOTINGS.
4. CONTRACTOR SHALL COORDINATE FOOTING ELEVATIONS WITH FINAL GRADING PLAN TO
CRACKING, OR SETTLEMENT OF THE ADJACENT CONSTRUCTION IN ANY WAY.
EXTREME CAUTION TO NOT UNDERMINE, DISTURB, DAMAGE, OR CAUSE UNDESIRABLE MOVEMENT,
3. WHEN WORKING NEAR EXISTING OR NEW CONSTRUCTION, THE CONTRACTOR SHALL EXERCISE
OF ITS COMPONENT PARTS.
CAUSE MOVEMENT OR OTHER DETRIMENTAL EFFECT TO THE STRUCTURE AS A WHOLE OR TO ANY
FOUNDATION ELEMENTS SHALL BE PROTECTED AGAINST FREEZING CONDITIONS THAT COULD
2. SUBSOILS SUPPORTING OR IN DIRECT CONTACT WITH FOOTINGS, SLABS-ON-GRADE, OR OTHER
1. SEE SECTION 31 00 00 FOR ADDITIONAL EARTHWORK REQUIREMENTS.
C. FOUNDATION WORK:
WELDED STEEL ANCHOR STUDS, ASTM A1044
HIGH STRENGTH BOLTS, ASTM F3125 GR A325
NUTS, WASHERS, ASTM A563
NON-HIGH STRENGTH BOLTS, ASTM A307
ANCHOR BOLTS, ASTM F1554 GR 36
WIRES AND TIES, ASTM A185
4. CONNECTION MATERIALS
COLD-FORMED STEEL, SEE SPECIFICATION 05 40 00
STEEL DECK, SEE SPECIFICATION 05 30 00
Fy = 36 ksiOTHER SHAPES, ASTM A36, Fy = 46 ksiHSS, ASTM A500, Fy = 50 ksiW SHAPES, ASTM A922,
3. STRUCTURAL STEEL MATERIALS:
WIRE REINFORCEMENT, ASTM A1064
REINFORCEMENT, ASTM A615 GRADE 60
f'c = 2000 PSIGROUT, ASTM C476 f'c= 2000 PSIMORTAR, ASTM C270 TYPE M OR S f'm = 2000 PSILOAD BEARING, ASTM C90
COMPRESSIVE STRENGTHS:
2. CONCRETE MASONRY UNITS (CMU):
REINFORCEMENT, ASTM A615 GRADE 60
0.30PERCENT BY WEIGHT OF CEMENT:
MAX WATER-SOLUBLE CHLORIDE ION CONTENT
0.45MAX WATER TO CEMENT RATIO:
4,500 PSI28-DAY COMPRESSIVE STRENGTH, f"c:
1. CONCRETE PROPERTIES:
B. MATERIALS:
PER MANUFACTUREROMEGA
PER MANUFACTURERR
PER MANUFACTURERCd
CANTILEVER COLUM SYSTEMS
DISPENSER CANOPY(IES):
1.25OMEGA
2.5R
2.5Cd
STEEL SPECIAL CANTILEVER COLUMN SYSTEMS
OFFLOAD CANOPY:
2.5OMEGA
5R
3.5Cd
SPECIAL REINFORCED MASONRY SHEAR WALLS
CONTROL BUILDING:
LATERAL FORCE RESISTING SYSTEMS
3500 PSFVERTICAL
160 PSF/FTLATERAL
ALLOWABLE SOIL BEARING PRESSURE CAPACITY
1.25RC III STRUCTURES
1.0RC II STRUCTURES
IMPORTANCE FACTOR
DDESIGN CATEGORY
DSITE CLASS
0.567gSD1
0.885gSDS
0.463gS1
1.328gSs
SEISMIC LOADING CRITERIA (ASCE 7-16)
104 MPHRC III STRUCTURES
98 MPHRC II STRUCTURES
DESIGN WIND SPEED:
CEXPOSURE
WIND CRITERIA (ASCE 7-16):
1.1RC III STRUCTURES
1.0RC II STRUCTURES
IMPORTANCE FACTOR:
24 INCHESFOOTING DESIGN DEPTH
9 INCHESFROST PENETRATION
25 PSFMINIMUM UNIFORM ROOF SNOW LOAD
15 PSFGROUND SNOW LOAD
SNOW CRITERIA
50 PSFFLOOR LIVE LOAD
20 PSFMINIMUM ROOF LIVE LOAD
16 PSFROOF DEAD LOADS
DESIGN LOADS:
III - FUEL TANKS AND PIPE SUPPORTS
II - CONTROL BUILDING AND CANOPIESRISK CATEGORY:
UFC 4-010-01 (2018)
UFC 3-460-01 (CHANGE 1, 2020)
UFC 3-301-01
UFC 1-200-01
TMS 402-16
MANUAL - NO. SDCFSFDM
SDI - STEEL DECK ON COLD-FORMED STEEL FRAMING DESIGN
SDI PUBLICATION NO. DDM04 (4TH EDITION)
SDI ROOF DECK DESIGN MANUAL - NO. RDDM2
IBC 2018
ASCE 7-16
AISI S100 (2016)
AISC 360-16
ACI 318-14
DESIGN CODES:
A. DESIGN DATA:
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16S-001.dwg
9:47:28 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
W A S -0
.d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U H
L
T
R U
C T
U R
A L N
O T
E
S-001
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
GENERAL CONCRETE REINFORCMENT NOTES:
7. C-C SPACING (S) IS DEFINED AS BELOW:
6. CONCRETE COVER SHALL MEET THE TABLE BELOW.
DRAWINGS.
5. EMBEDMENT LENGTHS IN CHART ARE TYPICAL EXCEPT AS NOTED IN DETAIL 2, OR AS INDICATED ON
THE HOOKED BAR CONTACTS THE LAYER OF MAIN REINFORCING SHOWN.
4. WHERE DRAWINGS ARE DETAILED SIMILAR TO DETAIL 2, EXTEND THE EMBEDMENT LENGTH SUCH THAT
F) CLEAR COVER IS LESS THAN THE BAR DIAMETER
E) CLEAR SPACING BETWEEN BARS IS LESS THAN 2 BAR DIAMETERS
D) LIGHT WEIGHT CONCRETE IS USED.
C) THE COVER OR C-C BAR SPACING IS NOT AS INDICATED IN TABLE.
B) fy > 60,000 PSI
A) f'c < 4500 PSI
OCCUR:
3. DEVELOPMENT AND SPLICE LENGTH SHOWN SHALL NOT APPLY IF ANY OF THE FOLLOWING CONDITIONS
FRESH CONCRETE IS CAST IN THE MEMBER BELOW THE DEVELOPMENT LENGTH OR SPLICE.
2. TOP BARS ARE DEFINED AS HORIZONTAL REINFORCEMENT SUCH THAT MORE THAN 12 INCHES OF
UNLESS OTHERWISE NOTED ON THE DRAWINGS.
1. REINFORCING BAR DEVELOPMENT AND LAP SPLICE LENGTH SHALL BE AS SHOWN IN THE TABLES
DEVELOPMENT AND
THIS TABLE DOES NOT APPLY WHEN f'c < 4500 PSI
BAR
SIZE
DEVELOPMENT LENGTH SPLICE LENGTH
OTHER TOP*
#3 14" 18" 23"
- MAIN REINF.
- LAPPED REINF.
CRITICAL
SECTION
6 x DIA. OF BAR - #3 TO #8 BARS
MINIMUM INSIDE BEND DIAMETER:
8 x DIA. OF BAR - #9 TO #11 BARS
10 x DIA. OF BAR - #14 & #18 BARS
SPLICE LENGTHS
#4 18" 23" 31"
#5 23" 29" 38"
#6 27" 35" 46"
#7 40" 40" 66"
#8 45" 46" 76"
#9 51" 52" 86"
CLEAR COVER REQUIREMENTS MUST BE MET
DEVELOPMENT LENGTHS
THIS TABLE DOES NOT APPLY WHEN f'c < 4500 PSI
#3 6"
OF HOOKED BARS
#4 7"
#5 8"
#6 10"
#7 11"
#8 13"
#9 15"
CLEAR COVER REQUIREMENTS MUST BE MET
BAR SIZE LENGTH OR MIN. EMBEDMENT
*SEE NOTE 2 IN GENERAL REINFORCING NOTES
MINIMUM CONCRETE COVER
CONCRETE EXPOSURE MEMBER REINFORCEMENT COVER, IN
IN CONTACT WITH GROUND
CAST AGAINST AND PERMANENTLY
ALL ALL 3
ACCORDANCE WITH OPTION #1 OR OPTION #2.
NOTE: UNLESS OTHERWISE INDICATED, THE CONTRACTOR HAS THE OPTION OF REINFORCING CORNERS IN
" WIDE SAW CUT.8
1FLOOR COVERING PROVIDE HARDBOARD INSERT OR
NOTE: SAW CUT SHOWN IS FOR SLABS WITHOUT FLOOR COVERING. FOR SLABS WITH
ELEVATION.
NOTE: SEE PLAN FOR SLAB THICKNESS, SLAB REINFORCEMENT, AND TOP OF SLAB
19"
24"
30"
36"
52"
59"
67"
CONTACT WITH GROUND
NOT EXPOSED TO WEATHER OR IN
1.5
ALL
#6 OR LARGER
#5 OR SMALLER
CONTACT WITH GROUND
EXPOSED TO WEATHER OR IN
WALLS
SLABS, JOINTS, AND
0.75#11 AND SMALLER
REINFORCING C-C SPACING
SCALE: NONE
E1
DETAIL 1
D4
HOOK DETAIL
SCALE: NONE
D9
DETAIL 2
SCALE: NONE
D6
CONSTRUCTION JOINT DETAILS
SCALE: NONE
B8
SLAB-ON-GRADE
CONTRACTION JOINT
SCALE: NONE
F8
SLAB-ON-GRADE
A1
TYPICAL SLAB-ON-GRADE DETAIL
SCALE: NONE
S
M
IN
E
M B
E D
M E
N T
L A
P S
P L
IC
E
S E
E N
O T
E
L A
P S
P L
IC
E
L E
N G
T H
12X BAR DIA.
L E
N G
T H
O R /2
M
IN
x D
IA
O F B
A R
G R
E A
T E
R
F
/4
(T
T H
IC
K N
E S
S
S E
E P
L A
N
LAP SPLICE
CLASS B
LAP SPLICE
CLASS B
L A
P S
P L
IC
E
C
A
S S B
T H
IC
K N
E S
S
T
A3
HORIZONTAL WALL CORNER REINFORCEMENT DETAIL OPTIONS
SCALE: NTS
OPTION #1 OPTION #2
CONTAINMENT STRUCTURES
WALLS ALL 2
OPTION #1 OPTION #2
DOUBLE CURTAIN WALL
SINGLE CURTAIN WALL
TOP*OTHER
" WIDE SAW CUT.8
1FLOOR COVERING PROVIDE HARDBOARD INSERT OR
NOTE: SAW CUT SHOWN IS FOR SLABS WITHOUT FLOOR COVERING. FOR SLABS WITH
T H
IC
K N
E S
S
T
SLAB REINF
SINGLE LAYER REINFORCEMENT
DOUBLE LAYER REINFORCEMENT
T /4 A
N D
G R
E A
T E
R O
F
3/8"
LAP SPLICE
CLASS B
LAP SPLICE
CLASS B
L A
P S
P L
IC
A
S S B
T /4 A
N D
G R
E A
T E
R O
F
3/8"
T /4 A
N D
G R
E A
T E
R O
F
3/8"
/4
/4
SLAB JOINT
CENTERED ON
RESERVOIR
SEALANT
SAWCUT
VERTICAL REINF. NOT SHOWN
WATERSTOP
6" BASE SEAL
WATERSTOP
6" BASE SEAL
WHERE INDICATED
STD. 90 DEG. HOOK
CORNER BAR
EXTRA VERTICAL BAR EXTRA VERTICAL BAR
SPECIFICATIONS (CENTER IN SLAB)
O.C. EPOXY COATED AND OILED PER
" DIA. SMOOTH DOWELS @ 16"4
31'-6" -
ON SLAB JOINT
RESERVOIR CENTERED
SAWCUT SEALANT
VERTICAL REINF. NOT SHOWN
HOOKED BAR
REINFORCEMENT
SEE PLAN FOR SLAB
SLABS ONLY)
BARRIER (INTERIOR
15 MIL VAPOR
WATER BARRIER
6" CAPILLARY
WHERE INDICATED
STD. 90 DEG. HOOK
EXTRA VERICAL BARS
VERTICAL REINF. NOT SHOWN
CORNER BAR
EXTRA VERTICAL BARS
VERTICAL REINF. NOT SHOWN
SPECIFICATIONS
O.C. EPOXY COATED AND OILED PER
" DIA. SMOOTH DOWELS @ 16"4
31'-6" -
SLAB REINF
ON SLAB JOINT
RESERVOIR CENTERED
SAWCUT SEALANT
HOOKED BAR
SLAB REINF
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16S-002.dwg
9:49:43 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S -0
.d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
N C
R E
T E S
T A
N D
A R
D D
E T
A
IL
S
C O
N C
R E
T E N
O T
E
S-002
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
MASONRY REINFORCMENT BARS NOTES:
OPENINGS. SEE A5 THIS SHEET.
9. ANCHOR SHEAR REINFORCING WITH A STANDARD HOOK AROUND VERTICAL BARS AT WALL ENDS AND
8. C-C SPACING (S) IS DEFINED AS SHOWN IN D1 THIS SHEET.
5 TIMES BAR DIA. STIRRUPS AND TIES
8 TIMES BAR DIA. #9
6 TIMES BAR DIA. #8 OR SMALLER
7. REINFORCEMENT SHALL HAVE A MINIMUM BEND DIAMETER AS FOLLOWS:
6. CLEAR DISTANCES BETWEEN PARALLEL BARS SHALL NOT BE LESS THAN THE BAR DIAMETER NOR 1 INCH.
BETWEEN THE REINFORCEMENT AND MASONRY UNIT.
5. GROUT SHALL HAVE A MINIMUM THICKNESS OF 1/4" FOR FINE GROUT AND 1/2" FOR COURSE GROUT
1.5" ALL BAR SIZES
B) MASONRY NOT EXPOSED TO EARTH OR WEATHER:
2" #6 OR LARGER
1.5" #5 OR SMALLER
A) MASONRY EXPOSED TO EARTH OR WEATHER:
4. CLEAR COVER SHALL MEET THE FOLLOWING:
C) THE COVER OR C-C BAR SPACING IS NOT AS LISTED BELOW.
B) fy > 60,000 PSI
A) f'm < 2000 PSI
DEVELOPMENT AND SPLICE LENGTH SHALL NOT APPLY IF ANY OF THE FOLLOWING CONDITIONS OCCUR:
76" #8
58" #7
43" #6
23" #5
15" #4
12" #3
3. DEVELOPMENT AND SPLICE LENGTHS SHALL BE AS FOLLOWS:
2. ACTUAL REINFORCEMENT YIELD STRENGTH SHALL NOT EXCEED 78 KSI (1.3fy).
THE LEAST CLEAR DIMENSION OF THE CELL. 2
OF THE NOMINAL MEMBER THICKNESS, AND NOT EXCEED 8
11. BARS SHALL BE #9 OR SMALLER, NOT EXCEED
- MAIN REINF.
- LAPPED REINF.
"8
MINIMUM BAR DIAMETER
MINIMUM BAR DIAMETER
MINIMUM BAR DIAMETER
JOINT REINFORCEMENT NOTES:
" OTHERWISE.2
1 WHEN EXPOSED TO EARTH OR WEATHER AND OF
" 8
52. JOINT REINFORCEMENT SHALL BE FULLY EMBEDDED IN MORTAR AND HAVE A COVER OF
DIA. BUT NOT LESS THAN 6 INCHES.
1. JOINT REINFORCEMENT SHALL HAVE A MINIMUM DEVELOPMENT LENGTH OF 48 X THE WIRE
ANCHOR BOLTS IN MASONRY NOTES:
BOLTS SHALL BE THE GREATER OF 4 TIMES THE DIAMETER OF THE ANCHOR BOLT AND 2 INCHES.
4. THE MINIMUM PERMISSIBLE EFFECTIVE EMBEDMENT LENGTH OF HEADED AND BENT BAR ANCHOR
OF THE BOLT NOR LESS THAN 1 INCH.
3. CLEAR DISTANCE BETWEEN PARALLEL ANCHOR BOLTS SHALL NOT BE LESS THAN THE DIAMETER
PROVIDED THAT THE SAME LIMITATIONS EXIST WITHIN THE GROUTED CELL.
BOLTS AND MASONRY UNIT. ANCHOR BOLTS MAY BE PLACED IN DRILLED HOLES THROUGH THE SIDE
" IN COURSE GROUT BETWEEN THE ANCHOR 2
1" IN FINE GROUT OR 4
1 TO MANTAIN A MINIMUM OF
2. ANCHOR BOLTS PLACED IN THE TOP OF GROUTED CELLS AND BOND BEAMS SHALL BE POSITIONED
" THICK. 2
" DIAMETER MAY BE PLACED IN MORTAR BED JOINTS THAT ARE AT LEAST4
1 ANCHOR BOLTS OF
1. HEADED AND BENT BAR ANCHOR BOLTS SHALL BE EMBEDDED IN GROUTED CELLS EXCEPT THAT
DETAIL
G8
DETAIL
F8
CMU CONTROL JOINT (MCJ) SECTION
A8
BOND BEAM UNIT AT CORNER
A1
D8
C8
STIRRUPS AND TIES #5 AND SMALLER
D5
BOND-BEAM INTERSECTION DETAIL
C3
REINFORCING C-C SPACING
D1
S-003
F8
S-003
G8
S
LAP SPLICE
L A
P S
P L
IC
E
A N
D X B
A R D
IA
G R
E A
T E
R O
F
END WALL HOOK DETAIL
A5
"8
"8
MINUS 13 X BAR DIA.
DEVELOPMENT LENGTH
"2
1BAR DIA. AND 2
GREATER OF 4 TIMESMINUS 13 X BAR DIA.
DEVELOPMENT LENGTH
MINUS 13 X BAR DIA.
DEVELOPMENT LENGTH
S A
M E
X B
A R D
IA
VERTICAL REINFORCEMENT
THIS SHEET FOR BEND REQUIRMENTS.
IN OPPOSITE DIRECTIONS. REFER TO D8
EITHER SIDE OF VERTICAL BAR AND HOOK
HORIZONTAL REINFORCEMENT, PLACE ON
VERTICAL REINFORCEMENT
PROVIDE STD HOOK AROUND
INTERIOR FACE
"4
1RAKE
BACKER ROD
"4
3RAKE
EXTERIOR FACE
JOINT SEALING SPECIFICATIONS)
ELASTOMERIC SEALANT (SEE
2-#4 BARS
KNOCKOUT SLOTS
BLOCK
SASH
CMU WALL
INTERIOR FACE OF 8"
CONTROL JOINT KEY
ALL CJ
STOP JOINT REINF. AT
BOND BEAM, OR AS SHOWN ON SHEET S-500
INTERMEDIATE BOND BEAMS AND HOOKED INTO TOP
VERTICAL REINFORCING CONTINUOUS THROUGH
BOND-BEAM INTERSECTION DETAIL
HORIZONTAL REINFORCEMENT, SEE
BENT BARS AT CORNERS TO MATCH SIZE OF
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16S-003.dwg
9:52:16 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S -0
.d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
M
S O
N R
Y S
T A
N D
A R
D D
E T
A
IL
S
M A
S O
N R
Y N
O T
E
S-003
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
R O
O F H
IG
H S
ID
E
R O
O F L
O W S
ID
E
3 1 2
SEE ROOF PLAN
5 5
A2
CONTROL BUILDING COMPONENT AND CLADDING PRESSURES
SCALE: NTS
ZONE
+ PRESSURE (PSF) - PRESSURE (PSF)
NOTE: "a" IS EQUAL TO 3'-0"
R O
O F H
IG
H S
ID
E
R O
O F L
O W S
ID
E
-19.7
-18.2
-31.04.8
5.3
5.7
12.1
13.6
-12.9
-27.2
WIND PRESSURE SCHEDULE
2a a a a a a a
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16S-004.dwg
9:54:26 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S -0
.d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
N T
R O
L B
U
IL
D
IN
G W
IN
D P
R E
S S
U R
E
S-004
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
SF201
E1
SF201
A1
SF201
A6
SF201
E6
SB301
B7
SB301
E8
24"
44"
24"
B1
CONTROL BUILDING PLAN
SCALE: 1" = 1'-0" 0 1' 2'6"
SLOPE1
12'-8"
(ELEV. 100'-0")
BARS @ 12" O.C. E.W.
6" THICK SLAB W/#4
(12" MIN. BGS)
TOP OF FOOTING
(ELEV. 100'-0")
TOP OF STEM WALL
BARS AT DOOR, 4" O.C.
REINFORCEMENT
(2) ADDITIONAL #4
OF ADJACENT SIDEWALK
EXTEND STOOP FULL WIDTH
WALL, SEE SECTIONS ON SB301
SLAB AND FOUNDATION STEM
3/8" EXPANSION JOINT BETWEEN
N O
R T H
P L A N
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16S-101.dwg
9:56:08 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S -1
.d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
N T
R O
L B
U
IL
D
IN
G P
L A
N
S-101
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
A1
CONTROL BUILDING ROOF PLAN
SCALE: 1" = 1'-0" 0 1' 2'6"
SLOPE
SF501
E7
SF501
E1
SF501
E4
IBC 2018, AND UFC 3-301-01.
7. FINAL DESIGN OF COLD FORMED STEEL MUST BE IN ACCORDANCE WITH AISI S100, ASCE 7-16, REQUIREMENTS AS INDICATED.
DEFLECTION AND PERFORMANCE REQUIREMENTS OF 05 30 00 AND 05 40 00 AND THE LOADING
AND THAT FINAL ROOF DESIGN REPRESENTS A COMPLETE AND USABLE SYSTEM MEETING THE
6. CONTRACTOR IS RESPONSIBLE FOR ENSURING COMPATIBILITY OF ALL ROOFING COMPONENTS
PATTERN WITH #12 TEK SCREWS AT A MINIMUM.
5. ATTACHMENT OF STEEL DECK TO COLD FORMED METAL SECTION MUST BE A MINIMUM OF 36-4
4. CONNECTIONS FOR COLD FORMED METAL SECTIONS ARE SCHEMATIC IN NATURE.
3. LISTED SECTION PROPERTIES FOR METAL DECKING ARE MINIMUM REQUIRED.
2. LISTED SIZES FOR COLD FORMED STEEL ROOF MEMBERS ARE MINIMUM REQUIRED SIZES.
STEEL DECKING.
1. CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF THE COLD FORMED STEEL ROOF AND THE
NOTES:
ROOF LOADING DIAGRAM
SCALE: 1/2" = 1'-0"
D8
D
LOAD
Lr
S
W
EQ
PSF
-31/5.7
+/-3
SF501
C7
D E
C K
IN
G S
P A
N
13'-8"
6"
6"
4'-10" 4'-0" 4'-10"
(T
Y P
CMU WALL BELOW
COLD FORMED ROOF JOIST
W
D, Lr, S, EQ
SCREWS IN A 36-4 PATTERN (MIN).
FASTEN TO JOISTS WITH #12 TEK
1.5" DEEP, 22 GA STEEL DECKING.
C JOISTS @ 16" O.C. MAX
6" DEEP COLD-FORMED
C-JOISTS AT ENDS
SECTION TO MATCH
6" DEEP COLD-FORMED
MASONRY WALL BELOW
SEE DETAILS SF501 AS REFERENCE
BETWEEN JOISTS AT PERIMETER
PROVIDE FULL DEPTH BLOCKING
PROVIDE BRACING BETWEEN C-JOISTS AS REQUIRED
N O
R T H
P L A N
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16SF101.dwg
10:06:09 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S
F .d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
N T
R O
L B
U
IL
D
IN
G R
O O
F P
L A
SF101
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
A1
WEST ELEVATION
SCALE: 1/2" = 1'-0"
A6
SOUTH ELEVATION
SCALE: 1/2" = 1'-0"
E6
NORTH ELEVATION
SCALE: 1/2" = 1'-0"
E1
EAST ELEVATION
SCALE: 1/2" = 1'-0"
FINISHED GRADE (TYP.)
FINISHED GRADE (TYP.)
FINISHED GRADE (TYP.)
FINISHED GRADE (TYP.)
F.F. EL.=100'-0" F.F. EL.=100'-0"
F.F. EL.=100'-0"F.F. EL.=100'-0"
0 2' 4'1' 0 2' 4'1'
0 2' 4'1'0 2' 4'1'
F.F. EL.=108'-4"
F.F. EL.=109'-4"
F.F. EL.=109'-4"
F.F. EL.=108'-4"
REINF. @ 32" O.C. (TYP.)
NO. 4 HORIZONTAL
BOND BEAM WITH (2)
BAR (TYP.)
NO. 4 CORNER
@ 32: O.C. (TYP.)
NO. 4 VERTICAL REINF.
BAR (TYP.)
NO. 4 CORNER
BARS, FIRST COURSE
8" BOND BEAM W/2 NO. 4
@ 32: O.C. (TYP.)
NO. 4 VERTICAL REINF.
OVER ALL WALL OPENINGS.
PLACE CONTINUOUSLY
LINTEL W/2 NO. 4 BARS,
WALL
LINTEL IN CONNECTING
2 NO. 4 BARS FROM
WALL
LINTEL IN CONNECTING
2 NO. 4 BARS FROM
REINF. @ 32" O.C. (TYP.)
NO. 4 HORIZONTAL
BOND BEAM WITH (2)
@ 32" O.C. (TYP.)
NO. 4 VERTICAL REINF.
REINF. @ 32" O.C. (TYP.)
NO. 4 HORIZONTAL
BOND BEAM WITH (2)
BAR (TYP.)
NO. 4 CORNER
(BOTH ENDS)
8" FROM CORNER
ADDITIONAL NO. 4
BAR (TYP.)
NO. 4 CORNER
(BOTH ENDS)
8" FROM CORNER
ADDITIONAL NO. 4
REINF. @ 32" O.C. (TYP.)
NO. 4 HORIZONTAL
BOND BEAM WITH (2)
@ 32" O.C. (TYP.)
NO. 4 VERTICAL REINF.
BARS, FIRST COURSE
8" BOND BEAM W/2 NO. 4
BARS, FIRST COURSE
8" BOND BEAM W/2 NO. 4
STAGGER (TOP COURSE)
8" BOND BEAM W/2 NO. 4 BARS,
STAGGER (TOP COURSE)
8" BOND BEAM W/2 NO. 4 BARS,
BARS (TOP COURSE)
8" BOND BEAM W/2 NO. 4
BARS (TOP COURSE)
8" BOND BEAM W/2 NO. 4
BARS, FIRST COURSE
8" BOND BEAM W/2 NO. 4
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16SF201.dwg
10:09:47 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S
F .d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
N T
R O
L B
U
IL
D
IN
G E
L E
V A
T
IO
N
SF201
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
EL. 100'-0"
FLOOR
FINISHED
M
IN
EL. 100'-0"
T.O. FDN WALL
12" BGS (MIN)
T.O. FOOTING
"8
E8
TYPICAL STRIP FOOTING SECTION
SCALE: 1" = 1'-0"
1'-0"
1'-8"
3" 1'-2" 3"
1'-2"
7"
8"
SLOPE 1/4":1'-0"
C L
R
SEE PLAN
EL. 98'-6"
T.O. FOOTING
EL. 100'-0"
FINISHED FLOOR
B7
STRIP FOOTING AT STOOP
SCALE: 1" = 1'-0"
1'-8"
3"1'-2"3"
0 1' 2'6"
0 1' 2'6"
C L
R
C L
R
9" BELOW FINISHED GRADE
#4 BARS @ 12" O.C. E.W.
3/8" EXPANSION JOINT MATERIAL
(3) #4 BARS
2" RIGID INSULATION
2" RIGID INSULATION
PROVIDE MINIMUM OF (3) BARS
#4 BARS @ 12" O.C. HORIZONTAL
TO MATCH CMU BLOCK ABOVE
CONCRETE WALL THICKNESS
(3) #4 BARS
#4 BARS @ 12" O.C.
(3) #4 BARS
(2) #4 BARS
#4 BARS @12" O.C. E.W.
(2) #4 BARS @ BASE
#4 HOOK @ 12" O.C.
REQUIREMENTS
REINFORCEMENT
SEE PLAN FOR
ASSUMED FINISHED GRADE
15 MIL VAPOR BARRIER
6" CAPILLARY WATER BARRIER
15 MIL VAPOR BARRIER
6" CAPILLARY WATER BARRIER
JOINT MATERIAL
3/8" EXPANSION
EDGE BEYOND
THICKENED
BOTTOM OF
12" UNCOMPACTED FILL
JOINT REINF. SEE S-003
(SEE CIVIL)
FINISHED GRADE
8" CMU
WALL REINFORCEMENT)
WALL AS DOWEL (32" O.C. TO MATCH
EXTEND EVERYOTHER BAR INTO
(ALTERNATE DIRECTION)
#5 BAR W/STD. HOOK @ 16" O.C.
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16SB301.dwg
10:02:36 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S
B .d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
N T
R O
L B
U
IL
D
IN
G F
O U
N D
A T
IO
N S
E C
T
IO
N
SB301
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
A
B
C
D
2'-0"
SEE NOTE
2'-0"
2'-0"
D
E7
TYPICAL OVEREXCAVATION DETAIL
SCALE: NTS
NOTE: SLOPE IN ACCORDANCE WITH REQUIREMENTS OF EM 385-1-1 AND 29 CFR 1926.
B B
A
C
OF LOOSE FILL PER LIFT.
+/- 2% OPTIMAL MOISTURE CONTENT. DO NOT EXCEED 8"
OF SECTION 31 00 00. COMPACT TO 95% PROCTOR WITHIN
STRUCTURAL FILL CONFORMING TO THE REQUIREMENTS
6" CAPILLARY WATER BARRIER
SLAB OVER VAPOR BARRIER AND
ON GRADE
AND STRUCTURAL SLABS
SPREAD & STRIP FOOTINGS
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16S-501.dwg
9:58:23 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S -5
.d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
V
E R -E
X C
A V
A T
IO
N D
E T
A
IL
S-501
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
L
6"
7" L
6"
6"
TYP
OPENING WITH ACTUAL MECHANICAL EQUIPMENT SUPPLIED.
NOTE: COORDINATE EXACT SIZE AND LOCATION OF
OPENING
"8
"8
TYP
TYP
C CF SECTION
L
C CF SECTION
L
ROOF STEEL DECK AND ATTACHMENT SCHEDULE
GAGE AND TYPE
STEEL DECK MINIMUM
+I (IN^4/FT) -I (IN^4/FT) +S (IN^3/FT) -S (IN^3/FT)
DECK ATTACHMENT
ENDS AND INTERMEDIATE SUPPORTS SIDE SUPPORTS SIDE LAPS
1.5B22 0.155 0.183 0.186 0.192 1 - #10 TEK SCREWS PER SPAN36-4 #12 TEK SCREWS 1 - #12 TEK SCREW PER SPAN
MINIMUM SECTION PROPERTIES
NOTE: SEE SPECIFICATION SECTION 05 30 0 STEEL DECKS FOR ADDITIONAL REQUIREMENTS.
L3X3X1/4
L
ROOF TO WALL LOW SIDE
SCALE: 1-1/2" = 1'-0"
E7
OUTSIDE OF WALLINSIDE OF WALL
TYP
L
6"
7"
ROOF BEAM ON WALL DETAIL
INSIDE OF WALL OUTSIDE OF WALL
EL. = VARIES
TOP OF CMU WALL
ARCHITECTURAL REQUIREMENTS FOR BUILDING ENVELOPE.
MUST SUFFICIENTLY BRACE AND SUPPORT DECKING AND MEET
SECTION MAY BE USED IN-LIEU OF 3/16" BENT PLATE. CONTRACTOR
2. AT CONTRACTOR'S OPTION APPROPRIATE COLD-FORMED METAL
TOP SURFACE OF THE COLD-FORMED JOISTS.
LEG LENGTH SUCH THAT TOP SURFACE OF PLATE IS FLUSH WITH THE
1. FOR 6"x6"x3/16" BENT PLATE AT TOP OF WALL ADJUST VERTICAL
NOTES:
ROOF TO WALL HIGH SIDE
E4
OUTSIDE OF WALL INSIDE OF WALL
6"
7" " STEEL DECK2
TYP
L
6"
6"
TYP
REQUIRED BY ARCH.
PROVIDE GUTTERING AS
TYP
OUTSIDE OF WALL INSIDE OF WALL
EL. = VARIES
TOP OF CMU WALL
ROOF TO WALL LOW SIDE
C7
NOTE: CONNECTION IS SIMILAR AT OPPOSITE WALL (HIGH SIDE OF ROOF).
TYPICAL ROOF PENETRATION DETAIL
C1
DECK FASTENER LAYOUT
SCALE: NTS
C4
ARCHITECTURAL REQUIREMENTS FOR BUILDING ENVELOPE.
MUST SUFFICIENTLY BRACE AND SUPPORT DECKING AND MEET
SECTION MAY BE USED IN-LIEU OF 3/16" BENT PLATE. CONTRACTOR
2. AT CONTRACTOR'S OPTION APPROPRIATE COLD-FORMED METAL
TOP SURFACE OF THE COLD-FORMED JOISTS.
LEG LENGTH SUCH THAT TOP SURFACE OF PLATE IS FLUSH WITH THE
1. FOR 6"x6"x3/16" BENT PLATE AT TOP OF WALL ADJUST VERTICAL
NOTES:
SCREWS IN 36-4 PATTERN (MIN.)
FORMED SECTION WITH #12 TEK
ROOF DECK, ATTACH TO COLD-
JOIST SECTION
600S250 COLD FORMED
" STEEL DECK2
BENT P
" CONT. 16
HORIZ. JOINT REINF.
8" CMU BOND BEAM W/2-#4 BARS CONT.
(FULL ROOF PERIMETER)
@ 16" O.C. CONT. ALONG WALL
WELDED ANCHOR STUDS
" DIA. ~ x 6" 8 5" P W/ 4
16"X
OPTION
AT CONTRACTOR'S
FRAMING MEMBERS
OR COLD FORMED
BETWEEN JOISTS
" CONT. BENT P 16
ROOF FLASHING, SEE ARCH.
FASCIA.
ROOF SLOPE WITH A FLUSH FACE
AS REQUIRED TO MATCH JOIST AND
PROVIDE CUSTOM BREAK SECTION
FASCIA.
ROOF SLOPE WITH A FLUSH FACE
AS REQUIRED TO MATCH JOIST AND
PROVIDE CUSTOM BREAK SECTION
ROOF FLASHING, SEE ARCH.
HORIZ. JOINT REINF.
8" CMU BOND BEAM W/2-#4 BARS CONT.
(FULL ROOF PERIMETER)
@ 16" O.C. CONT. ALONG WALL
WELDED ANCHOR STUDS
" DIA. ~ x 6" 8 5" P W/ 4
16"X
ACCESSORIES AS REQ'D.
PROVIDE WEB STIFFENERS AND ALL
SUPPLIER/CONTRACTOR PROVIDED DESIGN.
PROVIDE CLIP AND CONNECTION PER METAL
JOIST CLIP TO BEARING PLATE.
PROVIDE WEDLED ATTACHMENT OF
CS600x250
FLUSH FACE (TYP.)
FORMED SECTION AS REQ'D FOR
PROVIDE CUSTOM BREAK COLD
HORIZ. JOINT REINF.
8" CMU BOND BEAM W/2-#4 BARS CONT.
(FULL ROOF PERIMETER)
@ 16" O.C. CONT. ALONG WALL
WELDED ANCHOR STUDS
" DIA. ~ x 6" 8 5" P W/ 4
16"X
BENT P
" CONT. 16
OPTION
AT CONTRACTOR'S
FRAMING MEMBERS
OR COLD FORMED
BETWEEN JOISTS
" CONT. BENT P
" STEEL DECK2
JOIST TOP CHORD
COPE ANGLE LEG
INTERMEDIATE SUPPORT
SIDELAP CONN.
END SUPPORT CONN.
SIDE SUPPORT CONN.
(FULL ROOF PERIMETER)
@ 16" O.C. CONT. ALONG WALL
WELDED ANCHOR STUDS
" DIA. ~ x 6" 8 5" P W/ 4
16"X
HORIZ. JOINT REINF.
BARS CONT. (SEE ELEVATIONS)
8" CMU BOND BEAM W/2-#4
BENT P
" CONT. 16
ROOF FLASHING, SEE ARCH.
REQUIRED.
PROVIDE BRACING AND SUPPORTS AS
MATCH DEPTH OF MAIN ROOF SECTIONS.
ROOF FLASHING/FASCIA AS REQUIRED.
COLD-FORMED SECTION TO SUPPORT
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16SF501.dwg
10:14:31 AM 2/24/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
S
F .d w g
N
D U
B A
S
A
N
IE
D E
R B
U H
L
A
N
IE
D E
R B
U
N T
R O
L B
U
IL
D
IN
G R
O O
F D
E T
A
IL
SF501
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
12'-8"
SPLASHBLOCK - TYP.
STANDARD CONCRETE
AF.E.B.
- TYP.
8" CMU WALL
F5
A-201
E2
A-201
E5
A-201
F2
A-201
DOWNSPOUT
PREFINISHED METAL
ABOVE
METAL GUTTER
PREFINISHED
STRUCTURE - TYP.
EXPOSED
DRAWINGS
SEE STUCTURAL
STEEL JOISTS -
COLD-FORMED
ROOFING
SEAM METAL
STEEL STANDING
DOWNSPOUT
PREFINISHED METAL
BELOW
WALL LINE
1:12
SLOPE
EQUIP. ROOM
CONTROL BLDG
F8
A-201
" 1
E8
A-201
E8
A-201
E8
A-201
F8
A-201
F8
A-201
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16A-101.dwg
2:05:40 PM 2/25/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
A -1
.d w g
B
N O
H R
B
G O
R U
P
B
G O
R U
P
P L
A N
A N
D R
O O
F P
L A
N
F L
O O
R P
L A
N
R E
F L E
C T
E D C
E
IL
IN
G
C O
N T
R O
L B
U
IL
D
IN
G
A-101
4' 8'0 2'
F2
FLOOR PLAN
SCALE 1/4" = 1'-0"
PLAN
NORTH
REFLECTED CEILING PLAN
F5 SCALE 1/4" = 1'-0"
NORTH
ROOF PLAN
F8 SCALE 1/4" = 1'-0"
NORTH
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
2'-6"
30'-0"
19'-0" 8'-6"
PANELS ABOVE
METAL FASCIA
DOWNSPOUT
PANELS ABOVE
METAL FASCIA
DOWNSPOUT
- TYPICAL
STEEL COLUMN
- TYPICAL
STEEL COLUMN
SHEETS FOR SIZE
PEDESTAL - SEE STRUCT.
CONCRETE COLUMN
ELEV.=113'-0"
T.O. METAL PANELS
ELEV.=109'-6"
B.O. METAL PANELS
ELEV.=100'-0"
T.O. PAVEMENT
FIN. FLOOR/
PANELS
METAL FASCIA
COLUMNS
STEEL CANOPY
CIVIL SHEETS
CONC. CURB SEE
COLUMNS
STEEL CANOPY
ELEV.=109'-6"
B.O. METAL PANELS
PANELS
METAL FASCIA
ELEV.=100'-0"
T.O. PAVEMENT
FIN. FLOOR/
CIVIL SHEETS
CONC. CURB SEE
-TYP.
DOWNSPOUT
DOWNSPOUT
D9
A-102
A-5XX
F9
A-102
G9
A-102
F9
PANELS
METAL FASCIA
DOWNSPOUT
PANELS ABOVE
METAL FASCIA
METAL ROOF
STANDING SEAM
A-5XX
F9
2'-6"
30'-0"
1/12
SLOPE:
GUTTER - 6" BY 6"
PREFINISHED METAL
-TYPICAL
DOWNSPOUT (4" X 6")
GUTTER
PREFINISHED METAL
DOWNSPOUTS
PREFINISHED METAL
D9
A-102
8'-6"19'-0"
7.5
2'-6" 19'-0" 8'-6"
PANELS
METAL FASCIA
METAL ROOFING
STANDING SEAM
- SEE STR.
STEEL COLUMN
SEE CIVIL
FINISH GRADE -
- SEE STR.
CONC FOOTING
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16A-102.dwg
2:06:16 PM 2/25/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
A -1
.d w g
B
N O
H R
B
G O
R U
P
B
G O
R U
P
E L E
V A
T
IO
N S
F L
O O
R P
L A
N
O F F
L O
A D E
Q U
IO
P M
E N
T C
A N
O P
Y
A-102
4' 8'0 2'
F2
OFFLOAD EQUIPMENT CANOPY FLOOR PLAN
SCALE 1/4" = 1'-0"
PLAN
NORTH
OFFLOAD EQUIPMENT CANOPY - SOUTH ELEVATION
F9 SCALE 1/4" = 1'-0"
PLAN
NORTH
F5 SCALE 1/4" = 1'-0"
OFFLOAD EQUIPMENT CANOPY ROOF PLAN
OFFLOAD EQUIPMENT CANOPY - SOUTH ELEVATION
G9 SCALE 1/4" = 1'-0"
OFFLOAD EQUIPMENT CANOPY - SECTION
D9 SCALE 1/4" = 1'-0"
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
1 2
A
12'-6"
90'-0"
21'-8" 12'-6"
D
PANELS ABOVE
METAL FASCIA
DOWNSPOUT
PANELS ABOVE
METAL FASCIA
DOWNSPOUT
- TYPICAL
STEEL COLUMN
- TYPICAL
STEEL COLUMN
SHEETS FOR SIZE
PEDESTAL - SEE STRUCT.
CONCRETE COLUMN
F9
A-501
A-501
F9
A-501
F9
A-501
F9
A-501
F9
A-501
F9
1 2
B
D
PANELS ABOVE
METAL FASCIA
DOWNSPOUT
PANELS ABOVE
METAL FASCIA
- TYPICAL
DOWNSPOUT
SHEETS FOR SIZE
PEDESTAL - SEE STRUCT.
CONCRETE COLUMN
F9
A-501
A-501
F9
16'-6"
76'-0"
43'-0" 16'-6"
3 4
C
B
21'-8" 21'-8"
1 2
A
PANELS ABOVE
METAL FASCIA
DOWNSPOUT
- TYPICAL
STEEL COLUMN
F9
A-501
80'-0"
21'-8" 7'-6"
3 4
7'-6" 21'-8" 21'-8"
A
C
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16A-103.dwg
7:50:57 AM 3/2/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
A -1
.d w g
B
N O
H R
B
G O
R U
P
B
G O
R U
P
S T
A Y
L
F
O O
R P
L A
N S
D
IS
P E
N S
E R C
A N
O P
IE
S
A-103
4' 8'0 2'
F2
TACTICAL VEHICLE DISPENSER CANOPY FLOOR PLAN - LARGE (BID OPTION)
SCALE 1/4" = 1'-0"
PLAN
NORTH
PLAN
NORTH
C7 SCALE 1/4" = 1'-0"
NON- TACTICAL VEHICLE DISPENSER CANOPY FLOOR PLAN - LARGE (BID OPTION)
F7 SCALE 1/4" = 1'-0"
TACTICAL VEHICLE DISPENSER CANOPY FLOOR PLAN - INDIVIDUAL (BID OPTION)
F7 SCALE 1/4" = 1'-0"
NON- TACTICAL VEHICLE DISPENSER CANOPY FLOOR PLAN - INDIVIDUAL (BID OPTION)
2. NON-TACTICAL VEHICLE CANOPIES HAVE A 14'-0" CLEAR HEIGHT.
1. TACTICAL VEHICLE CANOPIES HAVE A 16'-0" CLEAR HEIGHT.
GENERAL NOTES:
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
BUILDING NUMBER
METAL FASCIA
PREFINISHED
ROOF TRIM
PREFINISHED METAL
ELECTRICAL
- TYP. SEE
LIGHT FIXTURE
CMU WALL
8" GROUND FACE
-SEE STR.
CONCRETE STOOP
GRADE
FINISH
= 109'-4"ELEVATION
TOP OF CMU
= 100'-0"ELEVATION
FINISH FLOOR
= 108'-4"ELEVATION
TOP OF CMU
= +/- 100'-0"ELEVATION
FINISH FLOOR
= 108'-4"ELEVATION
TOP OF CMU
= 100'-0"ELEVATION
FINISH FLOOR
ELEVATION = 109'-4"
TOP OF CMU
100'-0"ELEVATION
FINISH FLOOR
BUILDING NUMBER
= 100'-0"ELEVATION
FINISH FLOOR
= 108'-4"ELEVATION
TOP OF CMU
CMU WALL
8" GROUND FACE
GRADE
FINISH
SEAM METAL ROOFING
PREFINISHED STANDING
GUTTER
PREFINISHED METAL
DOWNSPOUT
PREFINISHED METAL
SPLASHBLOCK
CONCRETE
METAL FASCIA
PREFINISHED
CMU WALL
8" GROUND FACE
STOOP
CONCRETE
GRADE
FINISH
FACILITY REQUIREMENTS
SIGN - PER INSTALLATION
BUILDING NUMBER
DOWNSPOUT
PREFINISHED METAL
SPLASHBLOCK
CONCRETE
METAL FASCIA
PREFINISHED
CMU WALL
8" GROUND FACE
GRADE
FINISH
FACILITY REQUIREMENTS
SIGN - PER INSTALLATION
BUILDING NUMBER
DOWNSPOUT
PREFINISHED METAL
SPLASHBLOCK
CONCRETE
METAL FASCIA
PREFINISHED
CMU WALL
8" GROUND FACE
CONC. STOOP
GRADE
FINISH
STEEL DOOR FRAME
DOOR AND PRESSED
HOLLOW METAL
INSULATED
DOWNSPOUT
PREFINISHED METAL
SEAM METAL ROOFING
PREFINISHED STANDING
GUTTER
PREFINISHED METAL
CONCRETE SPLASHBLOCK
- SEE STRUCTURAL
CONCRETE FOUNDATION
- SEE STRUCTURAL
CONCRETE FLOOR SLAB
ON 4" STEEL STUDS @ 16" O.C.
5/8" GYPSUM WALLBOARD
PERIMETER INSULATION
2" RIGID INSULATION (R-13)
A-301
E2
= 109'-4"ELEVATION
TOP OF CMU
ELEVATION = VARIES
FINISH GRADE
ELEVATION = VARIES
FINISH GRADE
STOOP
CONCRETE
= +/- 100'-0"ELEVATION
FINISH FLOOR
= 107'-4"ELEVATION
TOP OF DOOR/WINDOW OPENING
-SEE STR.
FOUNDATION WALL
CONCRETE
TOP OF CMU
ELEVATION = 108'-4"
A-301
E6
FOUNDATION WALL
CONCRETE
FOUNDATION WALL
CONCRETE
100'-0"ELEVATION
FINISH FLOOR
METAL FASCIA
PREFINISHED
CMU WALL
8" GROUND FACE
GRADE
FINISH
SOFFIT
PREFINISHED METAL
SEAM METAL ROOFING
PREFINISHED STANDING
FASCIA AND TRIM
PREFINISHED METAL
- SEE STRUCTURAL
CONCRETE FOUNDATION
- SEE STRUCTURAL
CONCRETE FLOOR SLAB
ON 4" STEEL STUDS @ 16" O.C.
5/8" GYPSUM WALLBOARD
PERIMETER INSULATION
2" RIGID INSULATION (R-13)
A-301
E9
TOP OF CMU
A-301
E9
ELEVATION = VARIES
TOP OF CMU
ELEVATION = VARIES
OPP.
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16A-201.dwg
2:07:11 PM 2/25/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
A -2
.d w g
B
N O
H R
B
G O
R U
P
B
G O
R U
P
B U
IL
D
IN
G S
E C
T
IO
N S
B U
ID
IN
G E
L E
V A
T
IO
N S A
N D
C O
N T
R O
L B
U
IL
D
IN
G
A-201
4' 8'0 2'
E2
WEST ELEVATION
SCALE 1/4" = 1'-0"
SCALE 1/4" = 1'-0"F2
EAST ELEVATION
SCALE 1/4" = 1'-0"F2
SOUTH ELEVATION
E2 SCALE 1/4" = 1'-0"
NORTH ELEVATION
SCALE 1/4" = 1'-0"F8
BUILDING SECTION
SCALE 1/4" = 1'-0"e8
BUILDING SECTION
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
DOWNSPOUT
PREFINISHED METAL
SEAM METAL ROOFING
PREFINISHED STANDING
GUTTER
PREFINISHED METAL
CONCRETE SPLASHBLOCK
- SEE STRUCTURAL
CONCRETE FLOOR SLAB
ON 2-1/2" STEEL STUDS @ 16" O.C.
5/8" GYPSUM WALLBOARD
PERIMETER INSULATION
- SEE STRUCTURAL
AND FOOTING
CONCRETE FOUNDATION
STRUCTURAL
FILLED - SEE
CMU WALL - GROUT
8" GROUND FACE
= 100'-0"ELEVATION
FINISH FLOOR
DRAWINGS FOR MORE INFORMATION
FRAMING - SEE STRUCTURAL
COLD-FORMED STEEL
RUBBER BASE
INSULATION - R = 13
2" RIGID BOARD
VAPOR BARRIER
BARRIER
CAPILLARY WATER
COMPACTED FILL
A-501
E7
TOP OF CMU
ELEVATION = 108'-4"
ELEVATION = 109'-4"
TOP OF CMU
SEAM METAL ROOFING
PREFINISHED STANDING
FASCIA
PREFINISHED METAL
ROOF EDGE TRIM
PREFINISHED METAL
STRUCTURAL
FILLED - SEE
CMU WALL - GROUT
8" GROUND FACE
- SEE STRUCTURAL
AND FOOTING
CONCRETE FOUNDATION
CONCRETE STOOP
METAL DOOR
INSULATED HOLLW
W/ SPF INSULATION
DOOR FRAME - FILL
PRESSED STEEL
PERIMETER INSULATION
COMPACTED FILL
BARRIER
CAPILLARY WATER
- SEE STRUCTURAL
CONCRETE FLOOR SLAB
RUBBER BASE
VAPOR BARRIER
INSULATION - R = 13
2" RIGID BOARD
ON 2 1/2" STEEL STUDS @ 16" O.C.
5/8" GYPSUM WALLBOARD
CHANNELS - SEE STR.
COLD-FORMED STEEL
- SEE STR.
STEEL ROOF DECK
UNDERLAYMENT BD
MEMBRANE ON 1/2"
VAPOR RETARDER
INSULATION (R-35 MIN)
6" RIGID ROOF
SHIELD/AIR BARRIER
CONT. ICE AND WATER
A-501
E3
A-501
B3
SEAM METAL ROOFING
PREFINISHED STANDING
STRUCTURAL
FILLED - SEE
CMU WALL - GROUT
8" GROUND FACE
TOP OF CMU
ELEVATION = VARIES
SOFFIT
PREFINISHED METAL
AND FASCIA
ROOF EDGE TRIM
PREFINISHED METAL
= 100'-0"ELEVATION
FINISH FLOOR
= 100'-0"ELEVATION
FINISH FLOOR
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16A-301.dwg
2:07:54 PM 2/25/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
A -3
.d w g
B
N O
H R
B
G O
R U
P
B
G O
R U
P
L L S
E C
T
IO
N S A
N D D
E T
A
IL
S
C O
N T
R O
L B
U
IL
D
IN
A-301
E2
WALL SECTION
SCALE 1/4" = 1'-0"
0 1' 2' 3'
E6
WALL SECTION
SCALE 1/4" = 1'-0" E8
WALL SECTION
SCALE 1/4" = 1'-0"
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
SHEET ID
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
X X
X X
X X -X
X -X -X
X X
X
M A
R C
H
A N
S I
D
W
D W -2
-R -0
IN
T B
A S
E L
E W
IS
-M c C
H O
R D
W A
F U
E L F
A C
IL
IT
IE
S
L E
W
IS
M
A
IN
D E
S C
T
A Y
L O
R
E M
A R
G
IN
A L W
A Y S
S E
A T
T L E
W A
S E
A T
T L E D
IS
T R
IC
T
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
O M
A H
A D
IS
T R
IC
T
C
A P
IT
O L A
V E
N U
E
O M
A H
A
N E
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
SEAM METAL ROOFING
PREFINISHED STANDING
GUTTER
PREFINISHED METAL
- GROUT CELLS FULL
8" GROUND FACE CMU
MATCH ROOF COLOR
EAVE FLASHING TO
PREFINISHED METAL
WALLBOARD
5/8" GYPSUM
FRAMING @16" O.C.
2 1/2" STEEL STUD
INSUALTION - R-13
2" RIGID BOARD
FRAMING - SEE STRUCT
COLD-FORMED STEEL
WALLBOARD
5/8" GYPSUM - SEE STRUCTURAL
STEEL ROOF DECK
INSULATION ( R-35 TOTAL)
RIGID ROOF
- GROUT CELLS FULL
8" GROUND FACE CMU
TOP OF CMU
ELEVATION = 109'-4"
TOP OF CMU
ELEVATION = 108'-4"
FRAMING @16" O.C.
2 1/2" STEEL STUD
INSUALTION - R-13
2" RIGID BOARD
MEMBRANE
VAPOR RETARDER
MEMBRANE
VAPOR RETARDER
BARRIER MEMBRANE
FLUID APPLIED AIR
BARRIER MEMBRANE
FLUID APPLIED AIR
SPF INSULATION
SPF INSULATION
DOWNSPOUT
PREFINISHED METAL
UNDERLAYMENT BD
MEMBRANE ON 1/2"
VAPOR RETARDER
INSULATION (R-35 MIN)
6" RIGID ROOF
SHIELD/AIR BARRIER
CONT. ICE AND WATER
- SEE STRUCTURAL
STEEL ROOF DECK
AND BACKER ROD
CONTINUOUS SEALANT
SOFFIT ASSEMBLY
PREFINISHED METAL
FORMING DRIP
FASCIA AND CONT. CLEAT
PREFINISHED SHEET METAL
PLATE - SEE STR
CONT. BENT STEEL
OF 3/8" DIA. BOLTS @ 24" O.C.
AND SECURED WITH 2 ROWS
SEPARATED BY 2" BY 4",
CONT. 3/4" PLYWOOD
AND SPACERS
SUPPORT BRACKET
CONT. GUTTER
UNDERLAYMENT BD
MEMBRANE ON 1/2"
VAPOR RETARDER
PLATE - SEE STR
CONT. BENT STEEL
FORMING DRIP
FASCIA AND CONT. CLEAT
PREFINISHED SHEET METAL
SOFFIT ASSEMBLY
PREFINISHED METAL
AND BACKER ROD
CONTINUOUS SEALANT
ROOF COLOR
AND TRIM TO MATCH
ROOF EDGE FLASHING
PREFINISHED METAL
BOLTS @ 24" O.C.
ROWS OF 3/8" DIA.
AND SECURED WITH 2
SEPARATED BY 2" BY 4",
CONT. 3/4" PLYWOOD
CONT. CLEAT - TYP.
FRAMING - SEE STRUCT
COLD-FORMED STEEL
SEAM METAL ROOFING
PREFINISHED STANDING
FASCIA
PREFINISHED METAL
MATCH ROOF COLOR
RAKE FLASHING TO
PREFINISHED METAL
TOP OF CMU
ELEVATION = 108'-4"
PLATE - SEE STR
CONT. BENT STEEL
OF 3/8" DIA. BOLTS @ 24" O.C.
AND SECURED WITH 2 ROWS
SEPARATED BY 2" BY 4",
CONT. 3/4" PLYWOOD
- GROUT CELLS FULL
8" GROUND FACE CMU
AND BACKER ROD
CONTINUOUS SEALANT
SOFFIT ASSEMBLY
PREFINISHED METAL
FORMING DRIP
FASCIA AND CONT. CLEAT
PREFINISHED SHEET METAL
WALLBOARD
5/8" GYPSUM
FRAMING @16" O.C.
2 1/2" STEEL STUD
MEMBRANE
VAPOR RETARDER
BARRIER MEMBRANE
FLUID APPLIED AIR
SPF INSULATION
UNDERLAYMENT BD
MEMBRANE ON 1/2"
VAPOR RETARDER
INSULATION (R-35 MIN)
6" RIGID ROOF
SHIELD/AIR BARRIER
CONT. ICE AND WATER
- SEE STRUCTURAL
STEEL ROOF DECK
FRAMING - SEE STRUCT
COLD-FORMED STEEL
INSUALTION - R-13
2" RIGID BOARD
\\nwofpcadd01\AEC_WS_001\WA16\40000 Design Products\CAD_BIM\_Sheets\WA16A-501.dwg
2:08:34 PM 2/25/2021 PD: NWO_pdf.pltcfg DS: NWO_Screen.dscript.dscript
A -5
.d w g
B
N O
H R
B
G O
R U
P
B
G O
R
O F E
D G
E D
E T
A
IL
S
C O
N T
R O
L B
U
IL
D
IN
A-501
E3
ROOF EDGE DETAIL @ HIGH EAVE
SCALE 1/4" = 1'-0"
E7 SCALE 1/4" = 1'-0"
ROOF EDGE DETAIL @ LOW EAVE - GUTTER
0 3" 6" 9" 12"
SCALE 1/4" = 1'-0"C7
ROOF EDGE DETAIL @ RAKE
MANUFACTURER FINISH
OPENING TYPE WIDTH HEIGHT MATERIAL
101 NL 3'-0" 7'-0" HM
DOOR TYPE DESIGNATION:
NL NARROW LIGHT
SPACE NAME
FLOOR
MATERIAL FINISH
BUILDING
CONTROL
CONC
SCHEDULE ABBREVIATIONS:
VCT VINYL COMPOSITE TILE
PT PAINT
RB RUBBER BASE
GWB GYPSUM WALLBOARD
GLASS SCHEDULE
FUELING STATION CONTROL BUILDING
GL-1 1" INSULATING GLASS
VCT
CONC CONCRETE
EXP EXPOSED
SCHEDULE ABBREVIATIONS:
ALUM ALUMINUM
REMARKS
REMARKS
HEIGHT
VARIES -
DOOR DATA FRAME DATA DETAIL MISCELLANEOUS
GLASS TYPE MATERIAL FINISH HEAD JAMB SILL FIRE LABEL HDWR SET
GL - 1 1 HM PT
ABBREVIATIONS:
HM HOLLOW METAL
FINISH SCHEDULE
BASE NORTH WALL SOUTH WALL EAST WALL WEST WALL CEILING
MATERIAL MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL FINISH MATERIAL
RB GWB PT GWB PT GWB PT GWB PT EXP
MATL MATERIAL
MMF MANUFACTURE'S FINISH
MTL METAL
FINISH
PT
PT PAINT
-1
FINISH
PT
MMF
B2/A-701D2/A-701F2/A-701
DOOR SCHEDULE
DOOR TYPE
NOT TO SCALE
DOOR FRAME TYPE
A S S
C H
E D
U L E
D
SCHED
AS
2"
WINDOW TYPE
FLOOR
GLASS GL-1
6"
"GL-1
GLASS -
ROOM
NUMBER
F5/A-701 D5/A-701 B5/A-701
1. SEE SPECIFICATION SECTION 09 90 00 FOR PAINT GLOSS LEVELS.
GENERAL NOTES:
5. EXPOSED STRUCTURE SHALL BE PAINTED.
FLOOR FINISH TREATMENT.
4. SEE SPECIFICATION SECTION 03 30 00.00 10 FOR CONCRETE
3. NOT USED.
COATING SYSTEM.
2. ALL INTERIOR WALL SURFACES (GWB) SHALL RECEIVE A PAINT
EXTERIOR BUILDING COLORS.
1. SEE COLOR NOTES THIS DRAWINGS FOR INTERIOR AND
ROOM FINISH SCHEDULE REMARKS:
3.7 GLASS SHALL BE CLEAR.
3.6 LOUVERS SHALL MATCH THE ADJACENT WALL IN COLOR.
PAINTED TO MATCH CLEAR ANODIZED ALUMINUM.
AND EXTERIOR) SHALL BE CLEAR ANODIZED ALUMINUM OR
3.5. DOORS, DOOR FRAMES AND WINDOW FRAMES (INTERIOR
3.4. MORTAR SHALL STANDARD GRAY.
MATCH ROOF COLOR.
3.3. GUTTERS, DOWNSPOUTS, SOFFITS, AND PIPE GUARDS SHALL
OFFICER.
MATERIALS, BURGUNDY RED AS APPROVED BY THE CONTRACTING
3.2. GROUND FACED CMU SHALL MATCH MANUFACTURER MUTUAL
CONDUITS, ELECTRICAL APPURTENANCES, AND SIMILAR ITEMS.
METAL FLASHINGS AND TRIM, MECHANICAL UNITS, SOFFITS, PIPES,
COLOR APPLIES TO EXTERIOR ROOF SURFACES INCLUDING SHEET
MANUFACTURER AEP SPAN, COLOR COOL METALLIC SILVER. ROOF
3.1. STANDING SEAM METAL ROOF, SOFFIT, AND FASCIA SHALL MATCH
3. EXTERIOR:
2.13 NOT USED.
2.12 NOT USED.
WILLIAMS SW 7649 SILVERPLATE, RULE LINE TO BE BLACK.
URBANE BRONZE, SIGNAGE BACKGROUND TO MATCH SHERWIN
2.11.SIGNAGE TEXT TO MATCH SHERWIN WILLIAMS SW 7048
2.10 NOT USED.
2.9. NOT USED.
2.8. NOT USED.
2.7. NOT USED.
WINDOWS SHALL BE CLEAR ANODIZED ALUMINUM.
SHERWIN WILLIAMS SW 9562 FORTITIUDE. ALUMINUM
2.6. DOORS AND DOOR FRAMES, AND STEEL WINDOWS SHALL MATCH
2.5. NOT USED.
2.4. NOT USED.
2.3. RESILIENT/RUBBER BASE SHALL MATCH ROPPE 193 BLACK BROWN.
STANDARD WHITE.
2.2. CEILINGS/EXPOSED STRUCTURE SHALL MATCH MANUFACTURER'S
SW 7649 SILVERPLATE.
2.1. WALLS SHALL BE PAINTED TO MATCH SHERWIN WILLIAMS
2. INTERIOR:
DISTRICT, SOUTH OF HILSIDE DRIVE FACILITIES)
ARCHITECTURAL APPEARANCE STANDARDS (JACKSON
1.4. COLORS SHALL BE IN ACCORDANCE WITH THE JBLM
ITEMS.
PANELS, ACCESS PANELS, CONDUIT, GRILLES AND SIMILAR
PIPING ADJACENT TO THE WALL SURFACES, ELECTRICAL
TO THE WALL SURFACES COMPLETE, INCLUDING REVEALS,
1.3. INTERIOR WALL COLOR, AS APPLICABLE, SHALL APPLY
MANUFACTURER'S.
SELECTION OF EQUAL COLORS FROM OTHER
MATERIAL SPECIFIED ARE NOT INTENDED TO…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .