A.07.23_Solicitation_Amendment_0003.pdf

PDF 512 KB Posted

Attached to
MMD - Redundant Hydraulic System Flush Federal contract opportunity
Solicitation number
W912DW18Q0095
Issued by
Department of the Army Corps of Engineers Engineering District Walla Walla

About this file

Solicitation Amendment 0003

View the file

Other files for this federal contract opportunity

Other files attached to MMD - Redundant Hydraulic System Flush, newest first.
File Type Posted
A.07.23_Solicitation_Amendment_0002.pdf PDF
A.07.23_Solicitation_Amendment_0001.pdf PDF
A.01.13_Attachment_1_Schematic_of_Redundant_Hydraulic_Unit.pdf PDF
A.07.23_W912DW18Q0095.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

The purpose of this amendment is to answ er questions from offerors. Please see summary of changes for additional information.

If you are submitting an offer, ensure that you acknow ledge receipt of the amendment by completing Block 8 and 15A, 15B, and 15C.

All other terms and conditions remain unchanged.

1. CONTRACT ID CODE PAGE OF PAGES

J 1 3

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 18-Sep-2018

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street , County, State and Zip Code) X W912DW18Q0095

X 9B. DATED (SEE ITEM 11)

05-Sep-2018

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN

REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

18-Sep-2018

CODE

USA ENGINEER DISTRICT, SEATTLE

ATTN: CENWS-CT

4735 EAST MARGINAL WAY SOUTH, BLDG. 1202

SEATTLE WA 98134-2388

W912DW 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

W912DW18Q0095

SECTION SF 30 BLOCK 14 CONTINUATION PAGE

SUMMARY OF CHANGES

SECTION SF 1449 - CONTINUATION SHEET

The following have been added by full text:

QUESTIONS FROM OFFERORS

1.) Will USACE unload and load contractor equipment with their forklift or will the contractor need to be a forklift?

A. Within reason, USACE will help unload equipment. Forklift capacity is 12,000 lbs.

2.) What is the total oil capacity of the hydraulic system including the lines?

A. Tank size is 250 gallons. Lines are 1 inch in diameter (approximately 340 ft in length from tank to manifold).

3.). Please provide a list of filters to be replaced in 3.1.5 (Manufacturer, Model & Size, Quantity).

A. There are no filters in the redundant system.

4.) Will the old gas powered engine be retained by USACE or disposed of by the contractor?

A. Dispose by contractor

5.) What is the tube diameter of the 12 300 foot hydraulic lines?

A. Tube diameter is 1 inch.

6.) Please provide the quantity, amperage and distance of 480 volt electrical tie-ins at the top and bottom of the flush circuit.

A. 1 tie location approximately 20 ft from manifold. Cannot confirm voltage or amperage at this time.

Another tie in mechanical room approximately 75 ft from manifold. Voltage and amperage cannot be confirmed at this time.

7.) Are there special considerations for truck delivery of equipment at the bottom level? If so, what are they?

A. Yes. All wheel drive required. Grades are above 20%.

8.) If the bottom end of the flush circuit is at the 953’ level, what is the elevation of the side entry door where the generator and/or flush skids will be staged?

A. Elevation 976’

9.) If a contractor must demobilize due to rising water, how much warning will they receive and will equipment need to be broken down and moved or will flush operations just be temporarily suspended?

A. 12 hour notice will be given for water tight doors to be secured. If equipment is stored outside then equipment must be broken down and moved. If equipment is stored inside the tower, flush operations can continue.

10.) If the facility has inadequate 480V power, where can the contractor place a diesel generator and what length of cable is required to reach the flush circuit?

A. Generator placed at entrance to the Intake Tower Pedestrian Bridge. Would require approximately 300ft of cable – No high pool evacuation needed at this elevation. Generator placed at 976’ elevation would require approximately 75ft of cable – Evacuation could be needed at this elevation if flood conditions occur.

W912DW18Q0095

11.) Working 8, 10, or 12 hours per day is inefficient and more expensive during the flush so will the contractor be allowed to work 24 hours per day, 7 days per week during the flush?

A. Possibility exists to work extended hours based on submitted contractors schedule/plan. Must get approved by OPM.

(End of Summary of Changes)