A.03.09_W912DR21B0011_BARC Renovation of B434 Revised RTA Dwg Set 05.04.2021_AE102.pdf
PDF 46 MB Posted
- Solicitation number
- W912DR21B0011
About this file
This document outlines a federal contract opportunity for renovation and addition work at the Beltsville Agricultural Research Center in Beltsville, Maryland. The project consists of renovating an existing building and adding two new wings totaling 6,875 square feet to serve as a poultry quarantine facility. Renovation work includes creating office space, restrooms, and mechanical areas in the existing building. The site work will construct a temporary access road, improve an existing ring road, add parking spaces and concrete slabs, and complete grading, erosion control, and landscaping. The solicitation is full and open competition under NAICS code 236220 with a value between $1,000,000 and $5,000,000. The period of performance is 350 calendar days from notice to proceed. Bids are due by April 21, 2021 and the contracting agency is the Department of the Army Corps of Engineers Baltimore District.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
N
RD
FT MEADE
W
ILSONLLEWELLYN AV
AVE
STROBERTS
REECE
ROCKENBACH
MAPES
RD
RD
RD
CLARK
RD
WASHINGTON
D.C.
BALTIMORE
495p l l
50o 495p l564
BA
LT
O
EXIT
FORT MEADE-
ODENTON
l295JESSUP RD l198
SAVAGE RD
o
95p l175
W
AS
H.
SAVAGE RD
l
EXIT
MEADE
FORT
PA
RK
W
AY
70p 695p
100l
175l
3l
PROJECT
LOCATION
PROJECT
LOCATION
BI
OC
ON
TR
OL
RO
AD
POWDER MILL ROAD
POWDER MILL ROAD
BEAVER DAM ROAD
PRIVATE
PROPERTY
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E
US Army Corps of Engineers ®
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
VOLUME:
M
AR
K D
ES
C
R
IP
TI
O
N
G-001
C O
VE
R
S H
EE
T
BE
LT
SV
IL
LE
A
G R
IC
U
LT
U
R
AL
R
ES
EA
R
C H
C
EN
TE
R
M
AR
YL
AN
D
BA
LT
IM
O
R E
D
IS
TR
IC
T
H O
PK
IN
S
PL
AZ
A
BA
LT
IM
O
R E, M
AR
YL
AN
D
U S
AR
M
Y
EN
G
IN
EE
R
D
IS
TR
IC
T, B
AL
TI
M O
R E
EN
G
IN
EE
R
IN
G D
IV
IS
IO
N
M
IL
IT
AR
Y D
ES
IG
N B
R
AN
C H
W
JB
JD
D
JD
D
XX
X
FE
B
F-
9-
-2
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
R
EN
O
VA
TE
B
U
IL
D
IN
G
BALTIMORE DISTRICT
RENOVATE BUILDING 434
FEB 2021
THIS PROJECT WAS DESIGNED BY BALTIMORE DISTRICT OF THE
U.S. ARMY CORPS OF ENGINEERS. INITIALS OR SIGNATURES AND
REGISTRATION DESIGNATIONS OF INDIVIDUALS APPEAR ON THESE
PROJECT DOCUMENTS WITHIN THE SCOPE OF THEIR EMPLOYMENT
AS REQUIRED BY ER 1110-1-1852.
SUBMITTED:
CHIEF, MILITARY DESIGN BRANCH:
RECOMMENDED:
CHIEF, GEOTECHNICAL BRANCH:
RECOMMENDED:
CHIEF, ENGINEERING DIVISION:
GERALD PLACEK
CHUCK FREY
MARY FOUTZ
NTS
VICINITY MAP
NTS
LOCATION MAP
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
G-002
D R
AW
IN
G
IN
D
EX
BE
LT
SV
IL
LE
A
G R
IC
U
LT
U
R
AL
R
ES
EA
R
C H
C
EN
YL
AN
D
BA
LT
IM
O
R E
D
IS
TR
IC
T
H O
PK
IN
S
PL
AZ
A
BA
LT
IM
O
R E, M
AR
YL
AN
D
U S
AR
M
Y
EN
G
IN
EE
R
D
IS
TR
IC
T, B
AL
TI
M O
R E
EN
G
IN
EE
R
IN
G D
IV
IS
IO
N
M
IL
IT
AR
Y D
ES
IG
N B
R
AN
C H
W
JB
JD
D
JD
D
XX
X
FE
B
F-
9-
-2
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
R
EN
O
VA
TE
B
U
IL
D
IN
G
DRAWING INDEX
FIRE PROTECTION
FA001 FIRE ALARM GENERAL NOTES & LEGEND
FA101 FIRE ALARM FIRST FLOOR PLAN
FA102 FIRE ALARM SECOND FLOOR PLAN
FA501 FIRE ALARM DETAILS
FA601 FIRE ALARM RISER DIAGRAM
FA602 FIRE ALARM MATRIX
PLUMBING
P-001 PLUMBING NOTES AND LEGEND
P-101 DOMESTIC WATER
P-102 DRAIN, WASTE & VENT
P-501 DETAILS
P-601 SCHEDULES & ISOMETRIC
MECHANICAL
M-001 MECHANICAL NOTES & LEGEND
M-101 PLAN - HVAC
M-401 SECTIONS & ISOMETRICS
M-501 DETAILS
M-601 SCHEDULES
M-801 HVAC CONTROLS
M-802 HVAC CONTROLS
M-803 HVAC CONTROLS
ELECTRICAL
E-001 ELECTRICAL - LEGEND - LIGHTING AND POWER
ED101 DEMOLITION FLOOR PLAN
ES101 ELECTRICAL - SITE - DEMOLITION PLAN
ES102 ELECTRICAL SITE PLAN
ES501 ELECTRICAL - SITE - DETAILS
ES502 ELECTRICAL - SITE - DETAILS
ES503 ELECTRICAL - SITE - DETAILS
EG101 ELECTRICAL - GROUNDING PLAN/LIGHTNING PROTECTION PLAN
EG501 ELECTRICAL - LIGHTNING PROTECTION & GROUNDING DETAILS
EL101 ELECTRICAL - LIGHTING PLAN
EL102 ELECTRICAL - LIGHTING PLAN - ATTIC
EL601 ELECTRICAL- LIGHT FIXTURE SCHEDULE
EP101 ELECTRICAL - POWER FLOOR PLAN
EP102 ELECTRICAL - POWER FLOOR PLAN - ATTIC
EP601 ELECTRICAL - POWER - ONE LINE DIAGRAM
EP602 ELECTRICAL POWER - PANEL SCHEDULE
EP603 ELECTRICAL POWER - PANEL SCHEDULE
EP604 ELECTRICAL POWER - HVAC CONNECTION SCHEDULE
LP502 LANDSCAPE NOTES AND DETAILS
STRUCTURAL
S-001 GENERAL NOTES
S-002 GENERAL NOTES, LEGEND, SYMBOLS, ABBREVIATIONS
S-003 LOADING DIAGRAMS
S-004 TYPICAL CONCRETE DETAILS
S-005 TYPICAL CONCRETE DETAILS
S-006 TYPICAL CONCRETE DETAILS
S-007 TYPICAL LIGHT GAUGE DETAILS
S-008 TYPICAL LIGHT GAUGE DETAILS
S-009 TYPICAL LIGHT GAUGE DETAILS
S-010 TYPICAL LIGHT GAUGE DETAILS
S-011 TYPICAL STEEL DETAILS
SB101 OVERALL FOUNDATION PLAN
SB201 FOUNDATION SECTIONS AND DETAILS
SB202 FOUNDATION SECTIONS AND DETAILS
SB203 FOUNDATION SECTIONS AND DETAILS
SB301 MASONRY DETAILS
SF101 OVERALL FRAMING PLAN
SF201 ROOF FRAMING SECTIONS AND DETAILS
SF202 FRAMING SECTIONS AND DETAILS
SF203 ROOF FRAMING SECTIONS AND DETAILS
SF204 ROOF FRAMING SECTIONS AND DETAILS
SF501 SHEAR WALL SCHEDULE & DETAILS
ARCHITECTURE
A-001 ABBREVIATIONS & PROJECT INFORMATION
A-002 GENERAL DETAILS
A-003 LIFE SAFETY PLAN
A-004 AIR BARRIER DIAGRAMS
AD101 DEMOLITION - EXISTING FLOOR PLAN
AD201 DEMOLITION - EXISTING ELEVATIONS
AE101 FLOOR PLAN - OVERALL FIRST FLOOR
AE102 FLOOR PLAN - OVERALL SECOND FLOOR
AE103 REFLECTED CEILING PLAN
AE104 ROOF PLAN
AE201 ELEVATIONS - EXTERIOR BUILDING
AE301 BUILDING SECTIONS
AE302 BUILDING SECTIONS
AE303 WALL SECTIONS
AE304 WALL SECTIONS - POULTRY ADDITIONS
AE401 ENLARGED FLOOR PLANS
AE402 ENLARGED FLOOR PLAN - CLEAN / DIRTY
AE403 ENLARGED FLOOR PLAN - SHOWER / TOILET ROOM
AE501 ROOF DETAILS
AE502 ROOF DETAILS
AE503 CASEWORK DETAILS
AE601 PARTITION TYPES
AE602 DOOR SCHEDULE
AE603 DOOR DETAILS
AE604 WINDOW SCHEDULE
AF601 INTERIOR FINISH SCHEDULE
AF602 COLOR SCHEDULE
GENERAL INFORMATION
G-001 COVER SHEET
G-002 DRAWING INDEX
G-003 ABBREVIATIONS, LEGENDS, AND SYMBOLS
SURVEY/MAPPING
VF001 SURVEY DATA, LEGEND AND TIE-DOWNS
VF101 SURVEY PLAN
VF102 SURVEY PLAN
GEOTECHNICAL
B-100 BORING LOCATION PLAN - OVERALL
B-101 BORING LOCATION PLAN - SOUTH
B-102 BORING LOCATION PLAN - NORTH
B-300 SUBSURFACE EXPLORATION NOTES & BORING LOGS
B-301 SUBSURFACE EXPLORATION BORING LOGS
B-302 SUBSURFACE EXPLORATION BORING LOGS
B-303 SUBSURFACE EXPLORATION BORING LOGS
B-501 PAVEMENT SECTIONS AND TRANSITION DETAILS
B-502 SUBGRADE STABILIZATION DETAILS
B-503 CONCRETE PAVEMENT JOINT PLAN
B-504 JOINT SEALANT DETAILS
CIVIL
CE101 EROSION AND SEDIMENT CONTROL PLAN PHASE I
CE102 EROSION AND SEDIMENT CONTROL PLAN PHASE II
CE103 EROSION AND SEDIMENT CONTROL PLAN PHASE II
CE104 EROSION AND SEDIMENT CONTROL PLAN PHASE III
CE501 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS
CE502 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS
CE503 EROSION AND SEDIMENT CONTROL NOTES AND DETAILS
CE504 EROSION AND SEDIMENT CONTROL DETAILS
CE505 EROSION AND SEDIMENT CONTROL DETAILS
CE506 EROSION AND SEDIMENT CONTROL DETAILS
CD101 DEMOLITION PLAN
CG101 GRADING PLAN
CG102 STORMWATER MANAGEMENT PLAN
CS101 SITE LAYOUT PLAN
CS501 SITE DETAILS
CS502 SITE DETAILS
CU101 UTIILITY PLAN
CU102 UTILITY PLAN
CU201 STORM DRAIN PROFILES
CU202 SANITARY SEWER, FORCE MAIN AND WATER LINE PROFILES
CU203 WATER LINE PROFILES
CU301 STORMWATER MANAGEMENT SECTIONS
CU501 STORMWATER MANAGEMENT DETAILS
CU502 STORMWATER MANAGEMENT DETAILS
CU503 STORM DRAIN DETAILS
CU504 STORM DRAIN DETAILS
CU505 WATER LINE DETAILS
CU506 SANITARY SEWER DETAILS
LANDSCAPE
LP101 LANDSCAPE PLAN
LP102 LANDSCAPE PLAN ENLARGEMENTS
LP501 LANDSCAPE NOTES AND DETAILS
DRAWING ABBREVIATIONS
DRAWING SYMBOLS
A ---------------------
A LABEL CLASS A DOOR
A/C AIR CONDITION
A/C UNIT AIR CONDITIONING UNIT
A/E ARCHITECT/ENGINEER
AB ANCHOR BOLT
ACC ACCESSIBLE
ACS AUTOMATIC CONTROL SYSTEM
ACS DR ACCESS DOOR
ACS PNL ACCESS PANEL
ACT ACOUSTICAL CEILING TILE
ADA AMERICANS WITH DISABILITIES ACT
ADMIN ADMINISTRATION
AFC ABOVE FINISHED COUNTER
AFF ABOVE FINISHED FLOOR
AFG ABOVE FINISHED GRADE
AFS ABOVE FINISHED SLAB
AGGR AGGREGATE
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALUM ALUMINUM
ANOD ANODIZE
APC ACOUSTICAL PANEL CEILING
APPROX APPROXIMATE
AR AS REQUIRED
ARCH ARCHITECT
ASC ABOVE SUSPENDED CEILING
ASSY ASSEMBLY
ATC ACOUSTICAL TILE CEILING
AVG AVERAGE
AW ARCHITECTURAL WOODWORK
AWT ACOUSTICAL WALL TREATMENT
B ---------------------
B LABEL CLASS B DOOR
BALC BALCONY
BB BASEBOARD
BC BOOKCASE
BD BOARD
BDRY BOUNDARY
BFF BELOW FINISH FLOOR
BHMA BUILDER'S HARDWARE
MANUFACTURER'S ASSOCIATION
BLDG BUILDING
BLKG BLOCKING
BLT IN BUILT-IN
BN BULLNOSE
BOS BOTTOM OF STEEL
BOT BOTTOM
BP BUILDING PAPER
BRKT BRACKET
BSMT BASEMENT
BTWN BETWEEN
BUR BUILT-UP ROOFING
C ---------------------
C CONC CAST CONCRETE
C LABEL CLASS C DOOR
CAB CABINET
CATW CATWALK
CAV CAVITY
CBB CEMENTITIOUS (BACKER) BOARD
CD CONSTRUCTION DOCUMENTS
CDW CHILLED DRINKING WATER
CEM PLAS CEMENT PLASTER
CER CERAMIC
CF CONTRACTOR FURNISHED
CF/CI CONTRACTOR FURNISHED
/CONTRACTOR INSTALLED
CFE CONTRACTOR FURNISHED EQUIPMENT
CFLG COUNTERFLASHING
CFM CUBIC FEET PER MINUTE
CFMF COLD-FORMED METAL FRAMING
CFS CUBIC FEET PER SECOND
CG CORNER GUARD
CI CAST IRON
CIP CAST-IN-PLACE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLG DIFF CEILING DIFFUSER
CLG HT CEILING HEIGHT
CLL COLUMN LINE
CLO CLOSET
CLR COLOR
CLRM CLASSROOM
CMU CONCRETE MASONRY UNIT
CNDS CONDENSATE
CDR CARD READER
CO CLEANOUT
COL COLUMN
COMM COMMUNICATION
CONC CONCRETE
CONC FLR CONCRETE FLOOR
CONF CONFERENCE
CONT CONTINUE
COORD COORDINATE
CORR CORRIDOR
CP CONCRETE PIPE
CPT CARPET
CR CONTROL ROOM
CS CAST STONE
CSWK CASEWORK
CT CERAMIC TILE
CTB CERAMIC TILE BASE
CTF CERAMIC TILE FLOOR
CTR CENTER
CU FT CUBIC FEET
CW CASEMENT WINDOW
D ---------------------
D DEPTH
D LABEL CLASS D DOOR
DBL DOUBLE
DEMO DEMOLITION
DEPT DEPARTMENT
DET DETAIL
DIA DIAMETER
DIR DIRECTION
DIST DISTANCE
DOC DOCUMENT
DR DOOR
DS DOWNSPOUT
E ---------------------
E LABEL CLASS E DOOR
EA EACH
EF EACH FACE
EIFS EXTERIOR INSULATION AND
FINISH SYSTEM
EJ EXPANSION JOINT
ES EACH SIDE
EL ELEVATION
ELEV ELEVATOR
ENTR ENTRANCE
EPS EXPANDED POLYSTYRENE
BOARD (INSULATION)
EQ EQUAL
EWC ELECTRIC WATER COOLER
EXP EXPOSED
EXT EXTERIOR
EXT EXTINGUISHER
EXT GR EXTERIOR GRADE
F ---------------------
FA FIRE ALARM
FAAP FIRE ALARM ANNUNCIATOR PANEL
FAS BD FASCIA BOARD
FC BRK FACE BRICK
FCO FLOOR CLEANOUT
FD FLOOR DRAIN
FDN FOUNDATION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FED FEDERAL
FF FINISH FACE
FF EL FINISH FLOOR ELEVATION
FF INSUL FOIL BACKED INSULATION
FGL FIBERGLASS
FH FIRE HOSE
FHP FULL HEIGHT PARTITION
FIN FINISH
FIN BS FINISH BOTH SIDES
FIN FLR FINISH FLOOR
FIN GR FINISH GRADE
FIXT FIXTURE
FLDG FOLDING
FLEX FLEXIBLE
FLG FLOORING
FLMT FLUSH MOUNT
FLR FLOOR
FM FACTORY MUTUAL
FOC FACE OF CONCRETE
FOM FACE OF MASONRY
FR FIRE RESISTANT
FRG FIBER REINFORCED GYPSUM
FRMG FRAMING
FRP FIBERGLASS REINFORCED PLASTIC
FRTW FIRE RETARDANT TREATED WOOD
FS FEDERAL SPECIFICATION
FSTNR FASTENER
FTG FOOTING
FWC FABRIC WALLCOVERING
G ---------------------
G NATURAL GAS
GALV GALVANIZED
GB GRAB BAR
GFCI GOVERNMENT FURNISHED
CONTRACTOR INSTALLED
GFGI GOVERNMENT INSTALLED
GOVERNMENT INSTALLED
GFRG GLASS-FIBER-REINFORCED GYPSUM
GLZ GLAZING
GR FL GROUND FLOOR
GUT GUTTER
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
H ---------------------
HB HOSE BIBB
HDPE HIGH DENSITY POLYETHYLENE
HDW HARDWARE
HDWD HARDWOOD
HEPA HIGH EFFICIENCY PARTICULATE
AIR (FILTER)
HM HOLLOW METAL
HMD HOLLOW METAL DOOR
HORIZ HORIZONTAL
HT HEIGHT
HYDR HYDRAULIC
I ---------------------
IBC INTERNATIONAL BUILDING CODE
INSUL INSULATION
INT INTERIOR
ILO IN LIEU OF
J ---------------------
JAN JANITOR
K ---------------------
KPD KEYPAD
KIT KITCHEN
KPL KICKPLATE
L ---------------------
LAM LAMINATE
LAV LAVATORY
LBR LUMBER
LBS POUND
LDG LANDING
LF LINEAR FEET (FOOT)
LIB LIBRARY
LIN LINEAR
LKR LOCKER
LOC LOCATION
LT LIGHT
LVDR LOUVER DOOR
LVR LOUVER
M ---------------------
MACH RM MACHINE ROOM
MATL MATERIAL
MAX MAXIMUM
MC MOISTURE CONTENT
MD METAL DECK
MECH MECHANICAL
MECH RM MECHANICAL ROOM
MEMB MEMBRANE
MF MILL FINISH
MFR MANUFACTURER
MID MIDDLE
MIL STD MILITARY STANDARD
MIN MINIMUM, MINUTE
MIRR MIRROR
MISC MISCELLANEOUS
MLDG MOLDING (MOULDING)
MO MASONRY OPENING
MOD MODIFY
MB MOISTURE BARRIER
MTG MOUNTING
MTL METAL
MVBL MOVABLE
MWP MEMBRANE WATERPROOFING
N ---------------------
N NORTH
NA NOT APPLICABLE
NFPA NATIONAL FIRE PROTECTION
ASSOCIATION
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NP NO PAINT
NRC NOISE REDUCTI
O -------------------
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OFD OVERFLOW DRAIN
OFF OFFICE
OGL OBSCURE GLASS
OPH OPPOSITE HAND
OPNG OPENING
OPP OPPOSITE
OPQ OPAQUE
OWSJ OPEN WEB STEEL JOIST
OPR OPERABLE
ORD OVERFLOW ROOF DRAIN
ORIG ORIGINAL
P --------------------
PA PUBLIC ADDRESS
PAR PARAPET
PAT PATTERN
PB PULL BOX
PBD PARTICLEBOARD
PCC PRECAST CONCRETE
PCF POUNDS PER CUBIC FOOT
PCT PERCENT
PERF PERFORATED
PERIM PERIMETER
PH PHASE
PIL PILASTER
PL PROPERTY LINE
PL GL PLATE GLASS
PLAM PLASTIC LAMINATE
PLAS PLASTER
PLBG PLUMBING
PLG PILING
PLYWD PLYWOOD
PNL PANEL
PP PL PUSH/PULL PLATE
PR PAIR
PRCST PRECAST
PRKG PARKING
PS CONC PRESTRESSED CONCRETE
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
PTD PAPER TOWEL DISPENSER
PTDR PAPER TOWEL DISPENSER AND
RECEPTACLE
PTN PARTITION
PWR POWER
Q --------------------
QT QUARRY TILE
QTY QUANTITY
R --------------------
RB RESILIENT BASE
RBM REINFORCED BRICK MASONRY
RBR RUBBER
RC REINFORCED CONCRETE
RCP REFLECTED CEILING PLAN
RD ROOF DRAIN
RDG INS RIGID INSULATION, SOLID
REC RECESSED
REC ROOM RECREATION ROOM
REF REFERENCE
REM REMOVABLE
REP REPAIR
REPL REPLACE
REQ REQUIRE
REQD REQUIRED
RESIL RESILIENT
REST RESTROOM
RF RESILIENT FLOORING
RFG ROOFING
RH ROOF HATCH
RHR RIGHT HAND REVERSE
RL ROOF LEADER
RLG RAILING
RM ROOM
RO ROUGH OPENING
RSD ROLLING STEEL DOOR
RV ROOF VENT
RVL REVEAL
REVISION
NUMBER
NORTH ARROW w/
TRUE NORTH
INDICATION
ROOM TAG
ELEVATION NUMBER
SECTION
EXTERIOR ELEVATION
ENLARGEMENT,
DETAIL
SPOT ELEVATION
LEVEL NAME
SHEET NUMBER
SHEET NUMBER
SHEET NUMBER
A SHEET KEYNOTE
INTERIOR ELEVATION
SHEET NUMBER
PLAN NORTH
A101
SIM
A101
A101
A101
1 Ref
R ef
1Ref
R ef
Name Elevation
S --------------------
SB SPLASH BLOCK
SCHED SCHEDULE
SD SMOKE DETECTOR
SF SQUARE FOOT (FEET)
SFTWD SOFTWOOD
SGL SINGLE
SHT MTL FLASH SHEET METAL (FLASHING)
SHTHG SHEATHING
SHV SHELVING
SIM SIMILAR
SJ SCORED JOINT
SKLT SKYLIGHT
SLNT SEALANT
SMK SMOKE
SMLS SEAMLESS
SP EL SPOT ELEVATION
SPEC SPECIFICATION
SQ SQUARE
SQ IN SQUARE INCH
SQ YD SQUARE YARD
SST STAINLESS STEEL
ST STAIRS
STD STANDARD
STL JST STEEL JOIST
STL RF DK STEEL ROOF DECK
STOR STORAGE
STR STRINGERS
STRB/HRN STROBE/HORN
SUB FL SUBFLOOR
SV SHEET VINYL
SW SIDEWALK
T --------------------
T TREAD
T/S TUB/SHOWER
TC TERRA COTTA
TD TRENCH DRAIN
TEL TELEPHONE
TEMP TEMPORARY
TER TERRAZZO
TFF TOP OF FINISH FLOOR
THK THICKNESS
TK BD TACKBOARD
TMPD GL TEMPERED GLASS
TN TRUE NORTH
TOF TOP OF FOOTING
TOM TOP OF MASONRY
TOP TOP OF PARAPET
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TRANS TRANSOM
TRTD TREATED
TV TELEVISION
Room name
DETAIL OR SECTION
IDENTIFICATION
NUMBER
SHEET ON WHICH
CONDITION IS SHOWN
A101
LIMIT OF
REVISION
INDEX OF DRAWINGS
NUMBERING SYSTEM:
XX100
DISCIPLINE
DISCIPLINE MODIFIER
REFER TO A/E/C CAD STANDARD FOR
SHEET NUMBERINGSTANDARDS
SHEET SEQUENCE NUMBER WITHIN SERIES
SECOND CHARACTER =
DISCIPLINE MODIFIER:
A - ALARM
B - SUBSTRUCTURE
D - DEMOLITION
E - ELEMENTS
F - FINISHES
G - GRAPHICS
H - HVAC
I - INTERIORS
THIRD CHARACTER =
SHEET TYPE:
1 - PLANS
2 - ELEVATONS
3 - SECTIONS
4 - LARGE SCALE VIEWS
5 - DETAILS
6 - SCHEDULES
FIRST CHARACTER =
DISCIPLINE:
A - ARCHITECTURE
B - GEOTECHNICAL
C - CIVIL
D - PROCESS
E - ELECTRICAL
F - FIRE PROTECTION
G - GENERAL
H - HAZARDOUS MATERIALS
I - INTERIORS INTERIOR DESIGN
K - FOOD SERVICE
L - LANDSCAPING
M - MECHANICAL
P - PLUMBING
Q - EQUIPMENT
R - RESOURCE
S - STRUCTURAL
T - TELECOMMUNICATIONS
V - SITE / MAPPING
SHEET TYPE
BUILDING MATERIALS LEGEND
LEGEND AND SYMBOLS GENERAL NOTES
US Army Corps of Engineers ®
SHEET ID
U S
AR
M
Y C
O R
PS
O
F
EN
G
IN
EE
R
S
D R
AW
N
B Y:
D
ES
IG
N
ED
B
Y:
SU
BM
IT
TE
D B
Y:
SI
ZE
C H
EC
KE
D B
Y:
AN
SI
D
IS
SU
E D
AT
E:
C O
N
TR
AC
T
N O
SO
LI
C
IT
AT
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D
AT
E M
AR
K
D
ES
C R
IP
TI
O N
G-003
AB
BR
EV
IA
TI
O
N S, L
EG
EN
D
S, A
N D
S
YM
BO
LS
BE
LT
SV
IL
LE
A
G R
IC
U
LT
U
R
AL
R
ES
EA
R
C H
C
EN
YL
AN
D
BA
LT
IM
O
R E
D
IS
TR
IC
T
H O
PK
IN
S
PL
AZ
A
BA
LT
IM
O
R E, M
AR
YL
AN
D
U S
AR
M
Y
EN
G
IN
EE
R
D
IS
TR
IC
T, B
AL
TI
M O
R E
EN
G
IN
EE
R
IN
G D
IV
IS
IO
N
M
IL
IT
AR
Y D
ES
IG
N B
R
AN
C H
W
JB
JD
D
JD
D
XX
X
FE
B
F-
9-
-2
FI
LE
N U
M
BE
R
FI
LE
N
AM
E:
R
EN
O
VA
TE
B
U
IL
D
IN
G
34EARTH
BRICK
STEEL
CONCRETE MASONRY UNITS
CONCRETE
CRUSHED STONE
PLYWOOD
FINISH WOOD
ROUGH WOOD
ACOUSTICAL TILE COMPRESSIBLE FILLER
RIGID INSULATION
BATT INSULATION
PLASTER OR GWB
EARTH
BRICK
STEEL
CONCRETE MASONRY UNITS
CONCRETE
CRUSHED STONE
PLYWOOD
FINISH WOOD
ROUGH WOOD
ACOUSTICAL TILE COMPRESSIBLE FILLER
RIGID INSULATION
BATT INSULATION
PLASTER OR GWB
A. THE CONTRACTOR SHALL NOTIFY ALL LOCAL AGENCIES HAVING
JURISDICTION AND SHALL OBTAIN ALL NECESSARY PERMITS REQUIRED
FOR THE DEMOLITION AND REMOVAL OF THE DEBRIS RESULTING FROM
THE DEMOLITION.
B. CONTRACTOR SHALL RETAIN, AT THEIR EXPENSE, A REGISTERED
PROFESSIONAL ENGINEER LICENSED IN THE STATE IN WHICH THE
PROJECT IS LOCATED, TO DETERMINE ALL CONSTRUCTION PHASE
SHORING REQUIREMENTS. CONTRACTOR SHALL SUBMIT TO THE
OWNER AND THE ENGINEER OF RECORD SIGNED AND SEALED
DRAWINGS OUTLINING OPERATIONAL SEQUENCES, SHORING
CONCEPTUAL PLANS, AND METHODS USED FOR THE PROTECTION OF
STRUCTURES TO REMAIN AND NEIGHBORING STRUCTURES IN
ACCORDANCE WITH EM 385-1-1 AND SPECIFICATION SECTION 02 41 00.
C. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR THE PROTECTION
AND STABILITY OF EXISTING AND NEW STRUCTURES DURING
CONSTRUCTION.
D. DO NOT BEGIN DEMOLITION OR DECONSTRUCTION UNTIL
AUTHORIZATION IS RECEIVED FROM THE CONTRACTING OFFICER.
E. BEFORE UNDERTAKING ANY DEMOLITION WORK OR ORDERING
MATERIAL, ASCERTAIN BY SURVEY THE EXISTING CONDITIONS OF THE
PROPERTIES AND BUILDINGS ADJOINING OR IN CLOSE PROXIMITY TO
THE PREMISES. THE ARCHITECT SHALL BE NOTIFIED OF ANY
DISCREPANCY.
F. PROVIDE AND MAINTAIN BRACING AND SHORING AS NEEDED. KEEP
SUPPORTING STRUCTURE IN PLACE DURING NEW CONSTRUCTION AND
UNTIL NEW STRUCTURE IS COMPLETED.
G. STORE AND PROTECT IN DESIGNATED AREAS SPECIFIED BY THE
CONTRACTING OFFICER ALL MATERIALS TO BE REMOVED AND REUSED
TO MAXIMIZE THE VALUE DERIVED FROM SALVAGED AND RECYCLED
MATERIALS.
H. IF SAFETY OR INTEGRITY OF THE STRUCTURAL SYSTEM APPEARS TO BE
COMPROMISED, CEASE OPERATIONS IMMEDIATELY AND NOTIFY THE
OWNER AND THE ENGINEER. PROPERLY BRACE AND SUPPORT
STRUCTURE BEFORE RESUMING OPERATIONS.
I. ANY DAMAGE OCCURRING TO THE EXISTING STRUCTURE, ADJACENT
STRUCTURES, STREETS, SIDEWALKS, UTILITY LINES, OR ANY OTHER
PUBLIC OR PRIVATE PROPERTIES SHALL BE REINSTALLED TO THE
ORIGINAL CONDITION BY THE CONTRACTOR AT NO COST TO THE
OWNER OR THE ENGINEER
J. ALL OPENINGS IN EXISTING CONSTRUCTION SHALL BE SAW CUT OR
DRILLED. TAKE NECESSARY PRECAUTIONS DURING CUTTING AND
DRILLING OPERATIONS TO AVOID DAMAGE TO EXISTING ITEMS TO
REMAIN IN PLACE. REPAIR DAMAGED ITEMS AS APPROVED BY THE
CONTRACTING OFFICER
K. ALL EXISTING INFORMATION SHOWN IS REFERENCED FROM FIELD
MEASUREMENTS AND SHALL BE FIELD VERIFIED BY THE CONTRACTOR
PRIOR TO THE ALTERATION, FABRICATION, OR INSTALLATION OF ANY
EXISTING OR NEW BUILDING COMPONENTS.
L. DO NOT DISTURB EXISTING CONSTRUCTION BEYOND THE EXTENT
NECESSARY FOR INSTALLATION OF NEW CONSTRUCTION.
M. DO NOT BEGIN EXCAVATION, FILLING, AND OTHER EARTH-MOVING
OPERATIONS WITHOUT ADEQUATE BRACING OR SHORING IN AREAS
ADJACENT TO EXISTING STRUCTURES.
N. DO NOT BEGIN EXCAVATION, FILLING, AND OTHER EARTH-MOVING
OPERATIONS THAT ARE SEQUENTIAL TO DEMOLITION WORK IN AREAS
TO BE DEMOLISHED UNTIL ALL DEMOLITION WORK IN THE AREA HAS
BEEN COMPLETED AND DEBRIS REMOVED.
DEMOLITION NOTES
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-001
G E
N E
R A
L N
O T
E S
B E
L T
S V
IL
L E
A G
R
IC
U L T
U R
A L R
E S
E A
R C
H C
E N
T E
A R
Y L A
N D
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
A R
Y L A
N D
U S
A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T B
A L T
IM
O
R E
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
M
IL
IT
A
R Y
D E
S
IG
N B
R A
N C
H
P H
P H
R K
F E
B
F -3
-5
-2
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
R E
N O
V A
T E
B U
IL
D
IN
G
A. APPLICABLE CODES:
1. IBC 2018, INTERNATIONAL BUILDING CODE, 2018 EDITION
2. ASCE 7-16, MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER
STRUCTURES
3. ACI 318-14, BUILDING CODE REQUIREMENTS FOR STRUCTURAL
CONCRETE
4. ACI 530-16, BUILDING CODE REQUIREMENTS FOR MASONRY
STRUCTURES
5. AISC 325-17, STEEL CONSTRUCTION MANUAL, 15TH EDITION
6. AISC 360-16, SPECIFICATION FOR STRUCTURAL STEEL
BUILDINGS
7. AISI S100-16, NORTH AMERICAN SPECIFICATION FOR THE DESIGN
OF COLD-FORMED STEEL STRUCTURAL MEMBERS
8. AISI D100-17, COLD-FORMED STEEL DESIGN MANUAL
9. AWC NDS-18: NATIONAL DESIGN SPECIFICATION (NDS) FOR
WOOD CONSTRUCTION
10. AWS D1.1-15, AMERICAN WELDING SOCIETY STRUCTURAL
WELDING CODE
B. RISK CATEGORY . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
C. ROOF DEAD LOADS:
EAST ADDITION
DEAD LOAD . . . . . . . . . . . . . . . . . . . . . 15.0 PSF
COLLATERAL LOAD . . . . . . . . . . . . . . . . 8.5 PSF
WEST ADDITION
DEAD LOAD . . . . . . . . . . . . . . . . . . . . . . 15.0 PSF
COLLATERAL LOAD . . . . . . . . . . . . . . . . 8.5 PSF
D. DESIGN LIVE LOADS:
ROOF . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20 PSF
OFFICE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50 PSF
POULTRY AREA . . . . . . . . . . . . . . . . . . . . . . . . . 50 PSF
TOILET/SHOWER ROOMS . . . . . . . . . . . . . . . . . 75 PSF
OFFICE PARTITIONS . . . . . . . . . . . . . . . . . . . . . 15 PSF
MECHANICAL ROOM . . . . . . . . . . . . . . . . . . . . . . 150 PSF
STORAGE AREAS . . . . . . . . . . . . . . . . . . . . . . . . 125 PSF
PUBLIC AREAS, LOBBIES, ENTRIES . . . . . . . . 100 PSF
CORRIDORS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 100 PSF
STAIRS AND EXITS . . . . . . . . . . . . . . . . . . . . . . . 100 PSF
GRAIN STORAGE . . . . . . . . . . . . . . . . . . . . . . . . . 250 PSF
BOBCAT . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5K AXLE LOAD
E. SNOW LOAD:
GROUND SNOW LOAD (Pg). . . . . . . . . . . . . . . . . 25 PSF FLAT ROOF SNOW LOAD (Pf) . . . . . . . . . . . . . . . 12.6 PSF
SLOPED ROOF SNOW LOAD (Ps) . . . . . . . . . . . 12.6 PSF MINIMUM SNOW LOAD (Pm) . . . . . . . . . . . . . . . . 16 PSF
SNOW EXPOSURE FACTOR (Ce) . . . . . . . . . . . . 0.9 SNOW LOAD IMPORTANCE FACTOR (Is) . . . . . 0.8 THERMAL FACTOR (Ct) . . . . . . . . . . . . . . . . . . . . 1.0
SLOPE FACTOR (Cs) . . . . . . . . . . . . . . . . . . . . . . 1.0
FROST DEPTH . . . . . . . . . . . . . . . . . . . . . . . . . . . 26 INCHES
(SEE S-003 FOR SNOW LOAD DIAGRAMS)
F. WIND LOAD:
BASIC DESIGN WIND VELOCITY . . . . . . . . . . . . 104 MPH
EXPOSURE CATEGORY . . . . . . . . . . . . . . . . . . C
DIRECTIONALITY FACTOR (Kd) . . . . . . . . . . . . . 0.85 TOPOGRAPHIC FACTOR (Kzt) . . . . . . . . . . . . . . 1.0
ENCLOSURE CLASSIFICATION:
A) ENCLOSED
MEAN ROOF HEIGHT (h) . . . . . . . . . . . . . . . . . . 13.3 FT VELOCITY PRESSURE AT h (qh) . . . . . . . . . . . . 20 PSF
ROOF AND WALL COMPONENTS AND CLADDING:
(SEE WIND LOAD DIAGRAMS ON S-003)
G. SEISMIC LOAD:
DESIGN METHOD: EQUIVALENT LATERAL FORCE PROCEDURE
SS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.133 S1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.043 SDS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.141 SD1 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.068 SEISMIC IMPORTANCE FACTOR (Ie) . . . . . . . . 1.00
SITE CLASS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . D
SEISMIC DESIGN CATEGORY . . . . . . . . . . . . . . B
SEISMIC FORCE RESISTING SYSTEMS:
1. BLDG 434 - LIGHT FRAME WALLS W/ STEEL SHEETS (EW
DIRECTION
R = 6.5 Ω0 = 2.5 Cd = 4.0
2. BLDG 434 - STEEL ORDINARY MOMENT FRAMES (NS
DIRECTION)
R=3.5 Ω0 = 2.5 Cd = 3.0
SEISMIC BASE SHEARS:
1. BLDG 434
VE = 6.6 K
H. FUTURE LOADS: UNLESS SPECIFICALLY NOTED, THERE ARE NO
PROVISIONS FOR FUTURE FLOORS, ROOFS, OR OTHER LOADS.
A. THESE GENERAL NOTES ARE NOT INTENDED TO REPLACE
SPECIFICATIONS. SEE SPECIFICATIONS FOR REQUIREMENTS IN
ADDITION TO GENERAL NOTES.
B. THE STRUCTURAL DRAWINGS AND SPECIFICATIONS REPRESENT THE
FINISHED STRUCTURE, EXCEPT WHERE SPECIFICALLY SHOWN DO NOT
INDICATE THE METHOD OR MEANS OF CONSTRUCTION. THE
CONTRACTOR SHALL SUPERVISE AND DIRECT THE WORK AND SHALL BE
SOLELY RESPONSIBLE FOR ALL CONSTRUCTION MEANS, METHODS,
PROCEDURES, TECHNIQUES, AND SEQUENCE. ALL APPLICABLE
SAFETY REGULATIONS ARE TO BE FOLLOWED STRICTLY.
C. THE STRUCTURE HAS BEEN DESIGNED TO RESIST DESIGN LOADS ONLY
AS A COMPLETED STRUCTURE. APPLICATION OF CONSTRUCTION LOADS
TO THE PARTIALLY COMPLETED STRUCTURE SHALL BE CONSIDERED BY
THE CONTRACTOR AND INCLUDED IN THE DESIGN OF SHORING,
BRACING, FORMWORK, AND ANY OTHER SUPPORTING ELEMENTS
PROVIDED FOR CONSTRUCTION OF THE STRUCTURE. DURING
ERECTION AND UNTIL ALL PERMANENT CONNECTIONS ARE MADE, THE
CONTRACTOR MUST PROVIDE TEMPORARY BRACING FOR THE
STRUCTURE IN ALL DIRECTIONS. IN THE CASE OF A STEEL FRAME
STRUCTURE, THE FRAME SHALL BE CONSIDERED NON-SELF
SUPPORTING DURING CONSTRUCTION.
D. THE GENERAL CONTRACTOR SHALL CHECK AND VERIFY ALL
DIMENSIONS AND GRADE CONDITIONS, BOTH NEW AND EXISTING, AND
REPORT ANY DISCREPANCIES TO THE COR PRIOR TO ORDERING
MATERIALS OR PROCEEDING WITH ANY PHASE OF THE WORK.
E. THE CONTRACTOR SHALL COMPARE STRUCTURAL SECTIONS WITH
ARCHITECTURAL SECTIONS AND REPORT ANY DISCREPANCY TO THE
COR PRIOR TO FABRICATION OR INSTALLATION OF STRUCTURAL
MEMBERS.
F. DO NOT SCALE DIMENSIONS FROM DRAWINGS. THE CONTRACTOR
SHALL REQUEST FROM THE COR, NECESSARY DIMENSIONS NOT
SHOWN ON THE DRAWINGS.
G. PRINCIPAL OPENINGS IN THE STRUCTURE ARE SHOWN ON THESE
DRAWINGS. THE GENERAL CONTRACTOR SHALL EXAMINE THE
ARCHITECTURAL, MECHANICAL, ELECTRICAL, AND PLUMBING DRAWINGS
FOR REQUIRED OPENINGS AS THEY SHALL BE PROVIDED WHETHER
SHOWN ON THE STRUCTURAL DRAWINGS OR NOT. THE GENERAL
CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL OPENINGS
WITH ALL SUB-CONTRACTORS PRIOR TO CONSTRUCTION.
H. SEE ARCHITECTURAL DRAWINGS FOR FLOOR ELEVATIONS, FLOOR
SLOPES, AND LOCATIONS OF DEPRESSED FLOOR AREAS.
I. WHERE A DETAIL IS SHOWN FOR ONE CONDITION, IT SHALL APPLY FOR
ALL LIKE,SIMILAR CONDITIONS EVEN THOUGH NOT SPECIFICALLY
REFERENCED ON THE DRAWINGS.
A. THE FOUNDATION DESIGN AND THE MAXIMUM ALLOWABLE SOIL
BEARING PRESSURE OF 2000 PSF ARE BASED ON THE GEOTECHNICAL
INVESTIGATION REPORT DATED JULY 2020.
B. THE SUBGRADE AND UNDERFLOOR FILL SHALL BE PREPARED TO
A POINT THAT EXTENDS 5'-0" MINIMUM BEYOND THE LIMITS OF THE
FOUNDATION. MINIMUM SUBGRADE PREPARATION REQUIREMENTS
SHALL BE PER SPECIFICATION SECTION 31 00 00.
C. PRIOR TO THE PLACEMENT OF FOUNDATIONS, THE CONTRACTOR'S
INDEPENDENT SOIL TESTING AGENCY SHALL INSPECT FOOTING
ELEVATIONS TO CONFIRM SUITABLE MATERIAL AND CONDUCT
DYNAMIC CONE PENETROMETER (DCP) TESTS TO VERIFY THAT THE
FOUNDATION SOILS PROVIDE THE REQUIRED MINIMUM BEARING
CAPACITY. DCP TESTS SHALL BE CONDUCTED AT A MINIMUM OF TWO
LOCATIONS WITHIN THE FOOTPRINT OF MAT FOUNDATIONS, ONE
LOCATION AT COLUMN FOOTINGS, AND EVERY 25 FEET ALONG
CONTINUOUS STRIP FOUNDATIONS, BEGINNING AT THE
FOUNDATION BEARING ELEVATION AND CONTINUING TO A MINIMUM
DEPTH OF 2 FEET. THE DCP TEST SHALL BE COMPLETED IN
ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS.
WHERE COHESIVE SUBGRADE SOILS ARE ENCOUNTERED AT THE
BEARING ELEVATION, A STATIC CONE PENETROMETER IN LIEU OF DCP
SHALL BE USED TO VERIFY THE SPECIFIED MINIMUM ALLOWABLE
BEARING CAPACITY. IN THE EVENT THAT UNSUITABLE BEARING
MATERIALS ARE ENCOUNTERED, CONTACT THE COR. DO NOT OVER-
EXCAVATE WITHOUT EXPLICIT DIRECTION FROM THE CONTRACTING
OFFICER. WALLS RETAINING SOIL SHALL BE TEMPORARILY BRACED
DURING BACKFILLING AND UNTIL ALL SUPPORTING SOIL AND SLABS
ARE IN PLACE AND ARE AT DESIGN STRENGTH UNLESS NOTED
OTHERWISE ON PLANS AND DETAILS.
D. UTILITY LINES SHALL NOT BE PLACED THROUGH OR BELOW
FOUNDATIONS WITHOUT APPROVAL OF THE STRUCTURAL ENGINEER.
THE CONTRACTOR SHALL SUBMIT DETAILED DRAWINGS OF ALL SUCH
CONDITIONS PRIOR TO CONSTRUCTION.
E. IN ACCORDANCE WITH EARTHWORK SPECIFICATION, ALL STRUCTURAL
FILL PLACEMENT REQUIRED TO MEET FINAL GRADE WITHIN BUILDING
FOOTPRINT SHALL BE COMPLETED PRIOR TO BEGINNING
EXCAVATIONS FOR FOUNDATIONS. FOUNDATIONS SHALL BEAR IN
COMPACTED STRUCTURAL FILL OR SHALL BEAR A MINIMUM OF ONE
FOOT INTO VIRGIN SOILS.
DESIGN CRITERIA GENERAL NOTES
FOUNDATION NOTES
A. COLD FORMED TRUSSES SHALL CONFORM TO AISI COLD FORMED
STEEL DESIGN MANUAL USING STANDARD SHAPES AND LIGHT GAUGE
MANUFACTURERS ASSOCIATION (SSMA) NOMENCLATURE.
B. NO TRUSS MEMBER SHALL BE LESS THAN 20 GA THICKNESS MATERIAL.
C. A REGISTERED PROFESSIONAL ENGINEER SHALL PREPARE AND
PROVIDE SEALED DRAWINGS AND CALCULATIONS. SHOP DRAWINGS
SHALL INCLUDE ERECTION PLANS.
D. COLD-FORMED STEEL TRUSSES MUST BE GALVANIZED IN COMPLIANCE
WITH ASTM A653 G60 OR G90 AS SPECIFIED IN THE SPECIFICATION FOR
GRADE D (Fy=50 KSI) 54 MILS, 68 MILS, 98 MILS, AND FOR GRADE A (Fy=
33 KSI) 43 MILS AND THINNER.
E. ALL MEMBERS SPECIFIED ON THE DRAWINGS OR SPECIFICATIONS MAY
NOT BE SUBSTITUTED WITHOUT APPROVAL AND COMPLETE
STRUCTURAL DESIGN CALCULATIONS.
F. TRUSS MANUFACTURER SHALL PROVIDE A COMPLETED TRUSS
SYSTEM WITH PERMANENT BRACING, ANCHORAGE, AND ACCESSORIES
CAPABLE OF RESISTING ALL BUILDING CODE PRESCRIBED LOAD
COMBINATIONS INCLUDING WIND, SEISMIC, SNOW LOADS, AND LOADS
INDICATED IN CONTRACT DOCUMENTS.
G. LIGHT GAUGE TRUSSES VERTICAL DEFLECTIONS MUST NOT EXCEED
LIMITATIONS OF ICC IBC AND UFC.
H. FABRICATE COLD-FORMED STEEL TRUSSES AND ACCESSORIES
PLUMB, TRUE TO LINE WITH CONNECTIONS SECURELY FASTENED
ACCORDING TO AISI'S SPECIFICATIONS AND MANUFACTURER'S
WRITTEN INSTRUCTIONS.
I. FASTEN COLD-FORMED STEEL TRUSS MEMBERS BY WELDING, OR
SCREW FASTENINGS AS STANDARD WITH THE FABRICATOR.
J. WELDING MUST COMPLY WITH AWS D1.3 STRUCTURAL WELDING CODE.
WELDING MUST BE PERFORMED BY AWS-CERTIFIED WELDERS USING
70 KSI LOW HYDROGEN ELECTRODES. WELDS NEED TO HAVE
ADEQUATE SIZE TO ENSURE THE STRENGTH OF THE CONNECTION
USING 1/8" SIZE X 1" LONG MINIMUM. WELDS MUST BE COATED WITH
ZINC-RICH PAINT.
K. SCREWS SHALL BE ZINC-COATED, SELF-DRILLING WITH MINIMUM SIZES
OF #10-16 FOR 16 GAUGE MATERIAL AND THINNER, AND #12-14 FOR
MATERIAL THICKER THAN 16 GAUGE.
L. REINFORCE, STIFFEN AND BRACE TRUSSES TO WITHSTAND HANDLING,
DELIVERY, AND ERECTION STRESSES. LIFT FABRICATED TRUSSES TO
PREVENT DAMAGE OR PERMANENT DISTORTION. INSTALL, BRIDGE &
BRACE TRUSSES ACCORDING TO AISI'S CODED OF STANDARD
PRACTICE FOR COLD-FORMED STEEL STRUCTURAL FRAMING.
COLD FORMED LIGHT GAUGE TRUSSES
A. CONCRETE COMPRESSIVE STRENGTH IN 28 DAYS:
SITE WALLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4000 PSI, NORMAL WEIGHT
SLAB ON GRADE, FOOTINGS . . . . . . . . . . . . . . . 4000 PSI, NORMAL WEIGHT
SLAB ON GRADE SUBJECT TO VEHICLE
TRAFFIC . . . . . . . . . . . . . . . . . . . . . . . . . . 5000 PSI, NORMAL WEIGHT
EXTERIOR PAVEMENTS . . . . . . . . . . . . . . . . . . . 5000 PSI, NORMAL WEIGHT
B. REINFORCING:
TYPICAL - ASTM A615, GRADE 60
REINFORCING TO BE WELDED - ASTM A706 (INCLUDES
DEFORMED BAR ANCHORS)
WELDED WIRE FABRIC - ASTM A185 (FLAT SHEETS ONLY)
C. GROUT UNDER BASE PLATES SHALL BE HIGH STRENGTH (5000 PSI),
NON-METALLIC, NON-SHRINK.
D. REFER TO THE DRAWINGS FOR REINFORCING LAP REQUIREMENTS.
WHERE LAP SPLICES ARE NOT SHOWN, LAP PER ACI 318 OR CRSI
STANDARDS.
E. LAP WELDED WIRE FABRIC SHEETS PER SPECIFICATION SECTION 03 00
F. CLEAR COVER FROM FACE OF CONCRETE:
CAST IN PLACE CONCRETE (MEASURE TO OUTERMOST
REINFORCING):
WALLS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2"
COLUMNS (EDGE OF TIES) . . . . . . . . . . . . . . . . . . . 1-1/2"
FOOTINGS, CAISSONS . . . . . . . . . . . . . . . . . . . . . . 3"
SLABS EXPOSED TO EARTH AND WEATHER . . . 1-1/2"
ELEVATED BEAMS (EDGE OF STIRRUPS) . . . . . . 1-1/2"
G. PROVIDE REINFORCING IN SLABS ON GRADE, 2" FROM TOP OF SLAB:
5" SLABS . . . . . . . . . . . . . . . . . . . . . . . . #4@16" O.C. E.W.
H. WHERE SCHEDULED BARS ARE NOT PRESENT, PROVIDE CONTINUOUS #
5 TOP AND BOTTOM BARS TO SUPPORT STIRRUPS AS REQUIRED FOR
THE LENGTH OF THE STIRRUP SPACING IN ALL BEAMS.
I. BAR SUPPORTS FOR CONCRETE EXPOSED TO VIEW SHALL HAVE
PLASTIC COATED LEGS OR BE HOT-DIP GALVANIZED AFTER
FABRICATION.
J. MECHANICAL AND ELECTRICAL CONDUIT SHALL BE PLACED BELOW
SLABS ON GRADE. CONDUIT IN ELEVATED SLABS AND SLABS ON METAL
DECK SHALL RUN UNDER TOP LAYER OF SLAB REINFORCING. PROVIDE A
MINIMUM OF 1-1/2" CLEAR BETWEEN CONDUITS AND BETWEEN
REINFORCING AND ADJACENT CONDUITS PARALLEL TO REINFORCING. IF
MAXIMUM SIZE OF CONDUIT EXCEEDS ONE THIRD OF THE SLAB DEPTH,
ADDITIONAL FRAMING OR REINFORCING MAY BE NECESSARY AT THE
ENGINEER'S DISCRETION.
K. HEADED SHEAR STUDS SHALL CONFORM TO THE REQUIREMENTS OF
ASTM A108, GRADES 1010, 1015, 1017, OR 1020. STUDS SHALL BE END
WELDED IN THE FIELD.
L. EMBED PLATES MUST BE SET IN THE FORM BEFORE POURING
CONCRETE, NOT PLACED INTO TOP OF WET CONCRETE. THE
CONTRACTOR SHALL CONTACT THE STRUCTURAL ENGINEER FOR
CORRECTIVE DETAILS FOR ANY EMBED PLATES LEFT OUT OF
CONCRETE POURS.
M. REBAR SHALL NOT BE HEATED WITH A TORCH IN THE FIELD.
CAST-IN-PLACE CONCRETE/REINFORCING STEEL
EPOXY & EPOXY GROUT
A. ANCHOR BOLTS, REINFORCING STEEL, THREADED RODS, AND OTHER
EMBEDDED STEEL ITEMS SHALL BE SET INTO HARDENED CONCRETE
WITH EPOXY OR EPOXY GROUT ONLY WHERE DETAILED ON THE
DRAWINGS OR WHERE APPROVED BY THE ENGINEER.
B. THE MANUFACTURER'S DATA FOR ALL EPOXY AND EPOXY GROUT SHALL
BE SUBMITTED TO THE ENGINEER FOR APPROVAL PRIOR TO
INSTALLATION. FOLLOW THE MANUFACTURER'S SPECIFICATIONS AND
DIRECTIONS FOR MIXING AND APPLICATION. HEED ALL WARNING
LABELS. INSTALL IN ACCORDANCE WITH APPLICABLE SAFETY LAWS.
C. ALL EPOXY AND EPOXY GROUT SHALL DEVELOP A MINIMUM
COMPRESSIVE STRENGTH OF 8,000 PSI AND TENSILE STRENGTH OF
2,300 PSI.
D. ALL HOLES SHALL BE DRILLED WITH A DIAMETER NO LARGER THAN 1/8"
GREATER THAN THE DIAMETER OF THE STEEL MEMBER BEING
INSTALLED.
E. ALL HOLES SHALL BE CLEANED WITH COMPRESSED AIR AND SHALL BE
DRY PRIOR TO INSTALLATION OF EPOXY. HOLES SHALL BE FREE OF ALL
DELETERIOUS MATERIAL SUCH AS LAITANCE, DUST, DIRT, AND OIL.
F. THE CONTRACTOR PERFORMING EPOXY WORK SHALL BE APPROVED BY
THE MANUFACTURER FURNISHING THE EPOXY MATERIALS, AND SHALL
HAVE NO LESS THAN FIVE YEARS EXPERIENCE IN THE VARIOUS TYPES
OF EPOXY-RELATED WORK REQUIRED IN THIS PROJECT. A NOTARIZED
CERTIFICATION FROM THE MANUFACTURER ATTESTING TO THE
TRAINING SHALL BE SUBMITTED TO THE ENGINEER/ARCHITECT ALONG
WITH THE PROPOSAL TO DO THE WORK.
A. ALL COLD FORMED LIGHT GAGE METAL FRAMING AND CONNECTIONS
SHALL BE DESIGNED BY THE SUPPLIER'S ENGINEER. AT THE
ARCHITECT'S OR ENGINEER'S REQUEST, CONTRACTOR SHALL SUBMIT
CALCULATIONS FOR ALL COLD FORMED METAL FRAMING USED TO
SUPPORT CEILINGS AND EXTERIOR CLADDING.
B. ALL MEMBERS SHALL BE MANUFACTURED IN ACCORDANCE WITH THE
AMERICAN IRON AND STEEL INSTITUTE, "COLD FORMED STEEL DESIGN
MANUAL" (2017).
C. ALL MEMBERS SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI.
D. SUBMIT SHOP DRAWINGS FOR ALL COLD FORMED METAL FRAMING
USED TO SUPPORT CEILINGS AND EXTERIOR CLADDING. SHOP
DRAWINGS SHALL INDICATE PLACEMENT OF ALL FRAMING MEMBERS,
SHOWING TYPE, SIZE, GAGE, NUMBER, LOCATION, AND SPACING. THEY
SHALL ALSO INDICATE SUPPLEMENTAL STRAPPING, BRACING, SPLICES,
BRIDGING, ACCESSORIES, AND DETAILS REQUIRED FOR PROPER
INSTALLATION.
E. SHOP DRAWINGS SHALL SHOW THE SIZE AND LENGTH OF WELDS FOR
ALL WELDED CONNECTIONS AND TYPE, SIZE, AND NUMBER OF SCREWS
FOR ALL SCREWED CONNECTIONS. SUBMIT MANUFACTURER'S DATA
GIVING STRENGTH VALUES FOR SCREWS USED.
F. SHOP DRAWINGS SUBMITTED MUST BE PREPARED UNDER THE
SUPERVISION OF AND SEALED BY A REGISTERED PROFESSIONAL
ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED.
NON-LOAD BEARING COLD FORMED STEEL
A. PROVIDE ROOF DECK ATTACHMENT PATTERN PER SHEET NOTES AND
TYPICAL DETAILS, UNO.
B. ALL DECKING SHALL BE SUPPLIED IN LENGTHS SUFFICIENT TO PERMIT
THREE-SPAN SUPPORT CONDITIONS UNLESS SPECIFICALLY DETAILED
OTHERWISE.
C. THE CONTRACTOR SHALL VERIFY THE SIZE AND LOCATION OF ALL
OPENINGS, SLEVES, INSERTS, ETC WITH THE SHOP DRAWINGS OF THE
EQUIPMENT TO BE INSTALLED. SEE ARCHITECTURAL, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ALL OTHER PRINCIPAL OPENINGS IN ROOF
DECK.
D. DECK ACCESSORIES SUCH AS ADJUSTING PLATE AND END CLOSURE
PLATE MUST CONFORM WITH MANUFACTURER'S STANDARD
ACCESSORIES OF SAME MATERIAL & CONFIGURATION AS DECK.
E. REPLACE AND/OR REPAIR DECK DAMAGE IN ACCORDANCE WITH DECK
MANUFACTURER AND THE SPECIFICATIONS. REPLACE DECK FASTENING
DAMAGES.
F. PROVIDE ROOF DECK IN ACCORDANCE WITH THE FOLLOWING:
DEPTH . . . . . . . . . . . . . . . . . . . . . . . . . . 1-1/2"
SHEET WIDTH . . . . . . . . . . . . . . . . . . . 36" (30" MIN)
MINIMUM GAUGE . . . . . . . . . . . . . . . . 22 GA
WIDE-RIB TYPE . . . . . . . . . . . . . . . . . . . B
FINISH . . . . . . . . . . . . . . . . . . . . . . . . . . . GALVANIZED PER
ASTM A653, G90
MINIMUM SECTION MODULUS . . . . . . Sp = 0.186 in3, Sn = 0.192in3
MINIMUM MOMENT OF INERTIA, Ip . . . 0.107 in4
STEEL DECK
A. COLD FORMED METAL FRAMING SHALL BE DESIGNED, FABRICATED, AND
ERECTED IN ACORDANCE WITH AMERICAN IRON AND STEEL INSTITUTE
"COLD FORMED STEEL DESIGN M ANUAL" (2017).
B. NON-LOAD BEARING COLD FORMED LIGHT GAGE METAL FRAMING AND
CONNECTIONS SHALL BE DESIGNED BY THE SUPPLIER'S ENGINEER. AT
THE ARCHITECT'S OR ENGINEER'S REQUEST, CONTRACTOR SHALL
SUBMIT CALCULATIONS USED TO SUPPORT CEILINGS.
C. ALL MEMBERS SHALL HAVE A MINIMUM YIELD STRENGTH OF 33 KSI UNO.
D. SUBMIT SHOP DRAWINGS FOR ALL COLD FORMED METAL FRAMING
USED TO SUPPORT CEILINGS AND EXTERIOR CLADDING. SHOP
DRAWINGS SHALL INDICATE PLACEMENT OF ALL FRAMING MEMBERS,
SHOWING TYPE, SIZE, GAGE, NUMBER, LOCATION, AND SPACING. THEY
SHALL ALSO INDICATE SUPPLEMENTAL STRAPPING, BRACING, SPLICES,
BRIDGING, ACCESSORIES, AND DETAILS REQUIRED FOR PROPER
INSTALLATION.
E. SHOP DRAWINGS SHALL SHOW THE SIZE AND LENGTH OF WELDS FOR
ALL WELDED CONNECTIONS AND TYPE, SIZE, AND NUMBER OF SCREWS
FOR ALL SCREWED CONNECTIONS. SUBMIT MANUFACTURER'S DATA
GIVING STRENGTH VALUES FOR SCREWS USED.
F. SHOP DRAWINGS SUBMITTED MUST BE PREPARED UNDER THE
SUPERVISION OF AND SEALED BY A REGISTERED PROFESSIONAL
ENGINEER LICENSED IN THE STATE IN WHICH THE PROJECT IS LOCATED.
G. COMPLETE, UNIFORM, AND LEVEL BEARING SUPPORT SHALL BE
PROVIDED FOR THE TOP AND BOTTOM TRACKS OF STUD WALLS, OR
FULL SIZE SHIMS SHALL BE INSTALLED TO PROVIDE SUCH BEARING.
H. STUDS SHALL BE INSTALLED WITH THEIR BEARING ENDS POSITIONED
FLUSH AGAINST THE INSIDE TRACK WEB.
I. FULL-HEIGHT DOUBLE STUDS SHALL BE PROVIDED AT THE ENDS OF
PARTITIONS, AT WALL OPENINGS, BENEATH TRUSSES, AND AT OTHER
LOCATIONS INDICATED IN THE STRUCTURAL DRAWINGS. ATTACH THE
FLANGES OF DOUBLE STUDS TOGETHER PER DETAIL 5/S-010, UNO.
J. ANCHOR STUD TRACKS TO CONCRETE WITH LOW-VELOCITY POWDER
ACTUATED FASTENERS PER ICC ES ESR-2269 WITH A MINIMUM SHANK
DIAMETER OF 0.157", AND A MINIMUM PENETRATION OF 1-1/4", UNO.
LOCATE ANCHORS AT 3" FROM THE ENDS OF PARTITIONS , AND AT 12"
(MAX) UNO. SEE TYPICAL DETAILS AND SHEAR WALL SCHEDULE FOR
OVERALL SPACING REQUIREMENTS FOR BOTH BEARING AND NON-
BEARING WALLS.
K. PROVIDE BRIDGING AT 4'-0" O.C. SEE TYPICAL DETAILS FOR ADDITIONAL
INFORMATION.
L. SPLICES IN STUDS SHALL NOT BE PERMITTED. DO NOT CUT STUDS.
M. SLIDE CLIPS SHALL BE CAPABLE OF RESISTING A LATERAL FORCE OF
500 LBS.
N. WALL STUDS SHALL HAVE THE FOLLOWING MINIMUM EFFECTIVE
PROPERTIES. IN THE DESIGNATION BELOW, 362 IS THE MEMBER DEPTH
IN 1/100 INCHES, S IS THE MEMBER STYLE, 162 IS THE FLANGE WIDTH IN
1/100 INCHES, AND 54 IS THE MATERIAL THICKNESS IN MILS.
DESIGNATION DESIGN EFFECTIVE PROPERTIES
THICK. IX, IN4 SX, IN3 A, IN2 FY, KSI
600S162-54 0.0566 2.86 0.954 0.566 50 600S162-68 0.0713 3.53 1.180 0.693 50 600S200-54 0.0566 3.32 1.110 0.613 50 600S200-68 0.0713 4.10 1.370 0.764 50 600S200-97 0.1017 5.61 1.870 1.070 50
O. PROVIDE MATCHING THICKNESS TRACK (54 MIL MINIMUM) AT TOP AND
BOTTOM OF STUD WALLS AND AT HEADERS FOR STUD WALLS, UNO.
COLD FORMED METAL FRAMING
A. STRUCTURAL STEEL:
WIDE FLANGE SHAPES (W SECTIONS) . . . . . . . . . . . ASTM A992, GR. 50
CHANNELS, ANGLES, PLATES, RODS, AND BARS . . ASTM A36
SQUARE AND RECTANGULAR TUBES . . . . . . . . . . . ASTM A500, GR. C
PIPES . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM A53, GR. B HANGER (TIE) ROD . . . . . . . . . . . . . . . . . . . . . . . . . . . ASTM A615, GR. 60
B. ANCHOR BOLTS AND THREADED RODS MUST CONFORM TO ASTM F1554,
GR 36, UNO.
C. DESIGN, FABRICATION, AND ERECTION:
STEEL CONSTRUCTION MANUAL, 15TH EDITION . . . . . . . . . AISC 325-17
SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS . . . . AISC 360-16
D. BEAM SIMPLE SHEAR CONNECTIONS NOT DETAILED ON STRUCTURAL
DRAWINGS SHALL BE DESIGNED BY THE STEEL SUPPLIER FOR LOADS
SHOWN ON DRAWINGS OR FOR REACTIONS DETERMINED BY USING THE
ALLOWABLE UNIFORM LOAD AS TABULATED IN PART 2 OF THE AISC
MANUAL OF STEEL CONSTRUCTION FOR THE SECTION, SPAN, AND
STRENGTH OF STEEL SPECIFIED. CONNECTIONS SHALL BE MADE WITH
3/4"-DIAMETER BOLTS, ASTM F3125, GR A325 TIGHTENED TO A SNUG-
TIGHT CONDITION PER AISC REQUIREMENTS.
E. WHERE STEEL MEMBERS ARE WELDED AND NO SIZE IS SPECIFIED,
PROVIDE FULL LENGTH FILLET WELDS ON BOTH SIDES OF MEMBER.
WELD SIZES SHALL BE AS FOLLOWS UNLESS NOTED OTHERWISE:
MEMBER THICKNESS (INCHES) WELD SIZE (INCHES)
3/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/16 1/4 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/16 5/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3/16 3/8 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 7/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4 1/2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5/16
F. SPLICING OF STRUCTURAL STEEL MEMBERS IS PROHIBITED WITHOUT
PRIOR APPROVAL OF THE ENGINEER AS TO THE LOCATION AND TYPE OF
SPLICE TO BE MADE. ANY MEMBER HAVING A SPLICE NOT SHOWN ON
DRAWINGS AND DETAILED ON SHOP DRAWINGS WILL BE REJECTED.
G. ALL WELDING SHALL CONFORM TO THE AMERICAN WELDING SOCIETY
CODE. USE E70 SERIES ELECTRODES FOR ALL STRUCTURAL STEEL
WELDS.
H. SEE THE ARCHITECTURAL AND STRUCTURAL DRAWINGS FOR ALL ITEMS
REQUIRED TO BE HOT-DIP GALVANIZED AFTER FABRICATION. ALL
EXTERIOR LINTELS AND SHELF ANGLES ARE TO BE HOT-DIP
GALVANIZED.
I. ULTRASONIC INSPECTION BY THE TESTING LABORATORY SHALL BE
PER SPECIFICATION SECTION 05 12 00.
J. ALL STEEL EXPOSED TO VIEW SHALL BE CLASSIFIED AS
ARCHITECTURALLY EXPOSED STRUCTURAL STEEL (AESS) AS DEFINED
BY THE AISC CODE OF STANDARD PRACTICE AND SHALL HAVE A
PROTECTIVE COATING.
STRUCTURAL STEEL
@ AT
& AND
# NUMBER (QUANTITY)
AB ANCHOR BOLTS
ACI AMERICAN CONCRETE INSTITUTE
ADDL ADDITIONAL
ADH ADHESIVE
AESS ARCHITECTURALLY EXPOSED STRUCTURAL STEEL
AFF ABOVE FINISHED FLOOR
AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION
AISI AMERICAN IRON AND STEEL INSTITUTE
AL ALUMINUM
ALT ALTERNATE
ARCH ARCHITECTS - ARCHITECTURAL
ASTM AMERICAN SOCIETY FOR TESTING & MATERIALS
AT/FP ANTI-TERRORISM FORCE PROTECTION
AWS AMERICAN WELDING SOCIETY
B/ OR BOT BOTTOM
BCX BOTTOM CHORD EXTENSION
BFF BELOW FINISHED FLOOR
BLDG BUILDING
BM BEAM
BOS BOTTOM OF STEEL
BRG BEARING
BTWN BETWEEN
CJ CONTROL JOINT
CL CENTERLINE
CLR CLEAR
CMU CONCRETE MASONRY UNIT
COL COLUMN
CONC CONCRETE
CONN CONNECTION
CONST JT CONSTRUCTION JOINT
CONT CONTINUOUS
CONTR CONTRACTOR
COR CONTRACTING OFFICER'S REPRESENTATIVE
CTRD CENTERED
DBA DEFORMED BAR ANCHOR
DEFL DEFLECTION
DEMO DEMOLISH
DEPR DEPRESSION - DEPRESSED
DET DETAIL
DIAG DIAGONAL
Ø DIAMETER
DIM DIMENSION
DIST DISTANCE
DOD DEPARTMENT OF DEFENSE
DP DOUBLE PITCHED
DT DRAG TRUSS
DWG(S) DRAWING(S)
DWL(S) DOWEL(S)
EA EACH
ELEV ELEVATION
EMBED EMBEDMENT - EMBEDDED
ENGR ENGINEER
EQ EQUAL
EQUIP EQUIPMENT
EF EACH FACE
EJ EXPANSION JOINT
EN EDGE NAILING OR SCREWING
ES EACH SIDE
EOD EDGE OF DECK
EOS EDGE OF SLAB
EOW EDGE OF WALL
EW EACH WAY
EXIST/(E) EXISTING
EXP EXPANSION
EXT EXTERIOR
FDN FOUNDATION
FFE FINISHED FLOOR ELEVATION
FN FIED NAILING OR SCREWING
FOW FACE OF WALL
FRT FIRE-RETARDANT-TREATED
FS FAR SIDE
FTG FOOTING
GA GAUGE
GALV GALVANIZED
GT GIRDER TRUSS
GS GRIND SMOOTH
GSN GENERAL SHEET NOTES
HD HOLDOWN
HI HIGH
HORIZ HORIZONTAL
HSL HORIZONTAL SLOTTED HOLES
HSS HOLLOW STRUCTURAL SECTION
INT INTERIOR
JT JOINT
K KIP - KIPS
KB KWIK BOLT R
KSF KIPS PER SQUARE FOOT
KSI KIPS PER SQUARE INCH
LB LONG BAR
LBS POUND - POUNDS
LLH LONG LEG HORIZONTAL
LLV LONG LEG VERTICAL
LO LOW
LOC LOCATION
LW LIGHT WEIGHT
LWC LIGHT WEIGHT CONCRETE
MAX MAXIMUM
MC MOMENT CONNECTION
MECH MECHANICAL
MNFR MANUFACTURER
MD MIDDLE
MIN MINIMUM
MISC MISCELLANEOUS
ML MATCH LINE
MOW MIDDLE OF WALL
MP MASONRY PILASTER
d NAILS (PENNY) No NUMBER
NS NEAR SIDE
NTS NOT TO SCALE
NW NORMAL WEIGHT
NWC NORMAL WEIGHT CONCRETE
(N) NEW
ABBREVIATIONS
OC ON CENTER
OPNG OPENING
OPP OPPOSITE HAND
PED PEDESTAL
PL PLATE
PROJ PROJECTION
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT PRESSURE TREATED
REF REFERENCE
REINF REINFORCING
REQD REQUIRED
SB SHORT BAR
SCHD SCHEDULE
SIM SIMILAR
SMS SHEET METAL SCREW(S)
SOG SLAB-ON-GRADE
SP SHOT PIN
SPEC(S) SPECIFICATION(S)
SQ SQUARE
SS STAINLESS STEEL
STD STANDARD
STIFF STIFFENER
STIR STIRRUP
STL STEEL
STR STRUCTURAL
SW SHEARWALL
T/ TOP
T&B TOP AND BOTTOM
TCX TOP CHORD EXTENSION
THK THICKNESS
TOC TOP OF CONCRETE
TOS TOP OF STEEL
TOW TOP OF WALL
TYP TYPICIAL
UFC UNIFIED FACILITIES CRITERIA
UNO UNLESS NOTED OTHERWISE
VIF VERIFY IN FIELD
VSL VERTICAL SLOTTED HOLES
W/ WITH
WP WORK POINT
WWF WELDED WIRE FABRIC
ABBREVIATIONS (CONTINUED)
DIRECTION OF VIEW
LETTER INDICATES BUILDING SECTION
NUMBER INDICATES ELEV OR DETAIL
SHEET NUMBER WHERE
SECTION/DETAIL IS DRAWN
NUMBER INDICATES DETAIL NO.
SHEET NUMBER WHERE
DETAIL IS DRAWN
DIRECTION OF VIEW
ELEV NUMBER
SHEET NUMBER WHERE
ELEV IS DRAWN
FFE
SURFACE DESCRIPTION
FINISHED ELEVATION
ELEV=0'-0"
INDICATES PROGRESSIVE COLLAPSE
FRAMING MOMENT CONNECTION
PROGRESSIVE COLLAPSE
FRAMING SYSTEM
INDICATES PROGRESSIVE COLLAPSE
HANGER ROD ASSEMBLY SYSTEM
CENTERLINE AND GRIDLINE
MATCHLINE
S-101
S-101
A
S-101
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-002
G E
N E
R A
L N
O T
E S
L
E G
E N
D
S Y
M B
O L S
A
B B
R E
V
IA
T
IO
N S
B E
L T
S V
IL
L E
A G
R
IC
U L T
U R
A L R
E S
E A
R C
H C
E N
T
R
Y L A
N D
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
A R
Y L A
N D
U S
A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T B
A L T
IM
O
R E
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
M
IL
IT
A
R Y
D E
S
IG
N B
R A
N C
H
P H
P H
R K
F E
B
F -3
-5
-2
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
R E
N O
V A
T E
B U
IL
D
IN
G
HIGH STRENGTH BOLTING X
BEAM SPLICES AND CONNECTIONS X
STRUCTURAL STEEL FABRICATION AND ERECTION X
VERIFY METAL DECK CONNECTIONS X
TRUSS CONNECTIONS TO BUILDING SUPPORTS X
TRUSS TO TRUSS CONNECTIONS X
TEMPORARY ERECTION BRACING AND CONNECTIONS X
LIGHT GAUGE
TRUSSES
INSPECT TRUSSES FOR DAMAGE DUE TO SHIPPING OR
HANDLING
X
INSPECTION OF SCREW ATTACHMENT, BOLTING, ANCHORING,
AND OTHER FASTENING OF COMPONENTS WITHIN WIND AND
SEISMIC FORCE RESISTING SYSTEMS INCLUDING SHEAR
WALLS, BRACES, DIAPHRAGMS, DRAG STRUTS, AND HOLD
DOWNS.
X
STRUCTURAL LIGHT
GAGE STUD
CONSTRUCTION
MATERIAL VERIFICATION OF STUDS X
NOTE 1:
INSPECTOR SHALL BE FAMILIAR WITH ANCHOR
MANUFCACTURER'S WRITTEN INSTALLATION PROCEDURE AND
ESR REPORT.
VERIFICATION OF SUPPORTING MATERIAL'S CONDITION X
REVIEW OF INSTALLER'S QUALIFICATIONS INCLUDING
CERTIFICATION BY ANCHOR MANUFACTURER
X SEE NOTE 1
POST INSTALLED
ANCHORS TO
CONCRETE
USE OF PROPER ANCHOR SYSTEM AND MANUFACTURER X
INSPECT FORMWORK FOR SHAPE, LOCATIONS AND
DIMENSIONS OF THE CONCRETE BEING FORMED
X
PRIOR TO CONCRETE PLACEMENT, FABRICATE
SPECIMENS FOR STRENGTH TESTS, PERFORM SLUMP, AIR
CONTENT, AND TEMPERATURE TESTS
X
VERIFY USE OF REQUIRED DESIGN MIX X
ANCHOR BOLTS AND INSERTS X
CONCRETE
INSPECT AND VERIFY REINFORCEMENT PLACEMENT -
FOUNDATION WALLS/SLABS
X
PRIOR TO PLACEMENT OF COMPACTED FILL, INSPECT
SUBGRADE AND VERIFY THAT SITE HAS BEEN PREPARED
PROPERLY
X
VERIFY USE OF PROPER MATERIALS, DENSITIES, AND LIFT
THICKNESSES DURING PLACEMENT AND
COMPACTION OF COMPACTED FILL
X
PERFORM CLASSIFICATION AND TESTING OF
COMPACTED FILL MATERIALS
X
VERIFY EXCAVATIONS ARE EXTENDED TO PROPERVDEPTH
AND HAVE REACHED PROPER MATERIAL
X
SOILS
VERIFY MATERIALS BELOW SHALLOW FOUNDATIONS ARE
ADEQUATE TO ACHIEVE DESIGN BEARING CAPACITY X
ITEM
CONTINUOUS
INSPECTION
PERIODIC
INSPECTION
COMMENTS
SPECIAL INSPECTION SCHEDULE
UPPER
ROOF
VESTIBULE ROOF
8'-6"
SNOW DRIFT ON LOWER ROOF
N.T.S.
BALANCED & UNBALANCED SNOW LOADS
N.T.S.
16 PSF
26 PSF5 PSF 13 PSF
SEE PLAN 8 FT SEE PLAN
16 PSF
26 PSF13 PSF
SEE PLAN 8 FT SEE PLAN
5 PSF
Pb = 16.0 PSF
P d
P S
F
Pb + Pd = 65 PSF
UPPER ROOF
3e 2n 3r 3r 2n 3e
2e 2e
3e 2n 3r 3r 2n 3e
2r
1 1
3e 2n 3r3r 2n 3e
3e 2n 3r3r 2n 3e
2e
2r
1 1
2e
EXISTING STRUCTURE EXTENTS
3e 3e
2n
3r 3r
2r 2r 3e
2r
3e 3e3r 3r
2r 2r 2n3e2r
EXISTING STRUCTURE EXTENTS
EXISTING STRUCTURE EXTENTS
670 LB
US Army Corps of Engineers ®
SHEET ID
U S
A R
M Y
C O
R P
S O
F E
N G
IN
E
E R
S
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
S U
B M
IT
T
E D
B Y
S
IZ
E
C H
E C
K E
D B
Y
A N
S I D
IS
S
U E
D A
T E
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
G
2 3 4 5 6 7 8 9 10
F
E
D
C
B
A
D A
T E
M A
R K
D E
S C
R
IP
T
IO
N
S-003
L O
A D
IN
G
D
IA
G R
A M
S
B E
L T
S V
IL
L E
A G
R
IC
U L T
U R
A L R
E S
E A
R C
H C
E N
T
R
Y L A
N D
B A
L T
IM
O
R E
D
IS
T R
IC
T
H
O P
K
IN
S P
L A
Z A
B A
L T
IM
O
R E
M
A R
Y L A
N D
U S
A R
M Y
E N
G
IN
E E
R D
IS
T
R
IC
T B
A L T
IM
O
R E
E N
G
IN
E E
R
IN
G D
IV
IS
IO
N
M
IL
IT
A
R Y
D E
S
IG
N B
R A
N C
H
P H
P H
R K
F E
B
F -3
-5
-2
F
IL
E N
U M
B E
R
F
IL
E N
A M
E
R E
N O
V A
T E
B U
IL
D
IN
G
C&C WIND PRESSURE SCHEDULE
SURFACE
EFFECTIVE WIND AREA (FT²)
10 20 50 100
NEGATIVE ZONE 1 & 2e -43.6 -29.0
-43.6 -26.5 -16.0
NEGATIVE ZONE 2n, 2r, 3e
-63.5 -54.9 -43.6 -34.9
NEGATIVE ZONE 3r -75.5 -64.7 -50.4
-66.0 -39.6
POSITIVE ALL ZONES +16.0 +16.0 +16.0 +16.0
NEGATIVE ZONE 4 -21.6 -24.5 -23.1 -22.0
NEGATIVE ZONE 5 -39.6 -29.4 -26.6 -24.5
POSITIVE ZONE 4 & 5 21.6 22.5 21.1 20.0
1/16" = 1'-0"1
ROOF WIND LOADING DIAGRAM
1/16" = 1'-0"2
ROOF GRAVITY LOADING DIAGRAM -
SERVICE LOADS
DL = 23.5 PSF (INCLUDES SELF WEIGHT OF TRUSS) - 10 PSF APPLIED TO BOTTOM CHORD
LL = 20 PSF (UNREDUCIBLE)
1/16" = 1'-0"3
ROOF SNOW LOADING DIAGRAM
SL (BALANCED) = 16 PSF
SL (DRIFT) = 49 PSF
SL (DRIFT) = 21 PSF
NOTES
1. BOTTOM CHORD SHALL BE DESIGNED FOR MINIMUM UNIFORMED SUPERIMPOSED DEAD LOAD
OF 10 PSF AND MAXIMUM CONCENTRATED LOAD OF 100 LBS AT ANY LOCATION. LOADS NEED
NOT BE COMBINED WITH OTHER LOAD NOTES ON PLAN.
1 1/2" = 1'-0"4
TYPICAL TRUSS BOTTOM CHORD AXIAL
LOAD
NOTE: PRESSURES ARE IN POUNDS PER SQ FT (PSF)
NOTES:
1. THIS DETAIL SHALL ONLY APPLY FOR SLAB-ON-GRADE.
2. "t" DENOTES SLAB THICKNESS, SEE FOUNDATION PLANS.
3. SLABS WITH THICKNESS UP TO 6" SHALL BE TREATED AS SLAB-ON-GRADE.
4. LOCATION OF SLAB-ON-GRADE CONSTRUCTION JOINTS SHALL BE DETERMINED
BY THE CONTRACTOR. CAST SMOOTH DOWELS INTO FIRST POUR WHERE
CONSTRUCTION JOINTS WILL BE CREATED BY CONCRETE PLACEMENT
SEQUENCING.
5. SLAB-ON-GRADE CONTROL JOINT LOCATIONS INDICATED ON PLAN ARE
SCHEMATIC AND PRESENTED AS A GUIDELINE. SUBMIT CONTROL JOINT PLAN
FOR REVIEW AND APPROVAL.
6. SAW CUT SLAB-ON-GRADE CONTROL JOINTS WITHIN 8 HOURS OF SLAB POUR.
POUR BREAK CONSTRUCTION JOINT
SAW CUT CONTROL JOINT (CJ)
TYP SLAB CONSTRUCTION
1/4" x1/4" (t)
SLAB REINF,
TYP. SEE PLANS
SAWED
JOINT
2" CLR
2" CLR
#6x18" @12" oc
DOWELS W/ONE END
PAINTED AND OILED,
CENTERED ON JOINT
POUR BREAK
STOP SLAB REINF
AT CONST JOINT
2" CLR
SUBGRADE PER 3/S-004
t
SUBGRADE PER 3/S-004
t
SUBGRADE PER 3/S-004
t
DEEP
1/4" x1/4" (t)
SAWED
JOINT
DEEP
ELASTOMERIC
SEALANT
ELASTOMERIC
SEALANT
REINFORCED CONCRETE
SLAB-ON-GRADE
SEE PLAN
15 MIL VAPOR VARRIER
6" SELECT GRANULAR
MATERIAL
SATISFACTORY MATERIAL
THICKNESS VARIES DEPENDING
ON EXISTING GRADE AND SLAB
ELEVATION
EXISTING NATIVE SOIL
SLAB-ON-GRADE
6" CAPILLARY WATER BARRIER
REENTRANT CORNER
2#4 x 24" LONG @
CORNERS AND
DISCONTINUED CJs #4 x 24" LONG AT
DOOR OPENING,
TYP
8" TYP
2" C
LR
TY
P
2" C
LR
0' - 8"
1' - 0"
#4 @ 1'-4" oc
BENT BAR
BEND REINFORCING
MAX 1:6 SLOPE 0
T
O
1'-0"
1'-0"
2' - 0" (TYP)
SLAB REINF,
TYP, SEE PLANS
SLAB REINF,
TYP, SEE PLANS
CONT #4 NOSING BAR
S E
E P
L A
N S
E E
P L A
N
MATCH SLAB REINF
SIZE & SPACING
"T
6" MIN
"T
M
IN
"T
M
IN
CONC SLAB OR FDN SEE NOTE 1
SEE NOTE 2PIPE, SEE NOTE 3
NOTES:
1. TYP SLAB REINF PER PLAN.
2. SUBGRADE MATERIALS PER DWGS AND SPECS
3. SEE OTHER DISCIPLINE DWGS FOR PIPE LOCATIONS
/2
M
IN
M
IN
M A
X
A
A
SECTION A
CONC FILL TO BE PLACED
ACROSS FULL WIDTH OF PIPE
TRENCH BEFORE FTG IS PLACED
PIPE
SLEEVE W/ 1/2" MIN
CLR AROUND PIPE
CONC FTG
STEM WALL
AS OCCURS
NOTE: DO NOT ROUTE PIPES THRU
ANY FTG NOR BELOW COLUMN FTG.
8" TO 3' - 0" BELOW FOOTING
SLEEVE W/ 1/2" MIN
CLR AROUND PIPE
CONC FTG
STEM WALL
AS OCCURS
PIPE, SEE OTHER
DISCIPLINE DRAWINGS
CONC FILL TO BE
PLACED ACROSS FULL
WIDTH OF PIPE TRENCH
BEFORE FTG IS PLACED
GREATER THAN 3'-0" BELOW FOUNDATION
PIPE, SEE OTHER
DISCIPLINE DRAWINGS
STEM WALL AS
OCCURS
CON…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .