W912DQ22R4010 Command Suite Plans.pdf
PDF 399 KB Posted
- Solicitation number
- W912DQ22R4010
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
EC
WKS
EC
WKS
EC
WKS
ARY
LE
E
PTR
PTR
PTR
PTR
FAX
405 SF
CMDR OFFICE
251 SF
ADMIN
870 SF
WAITING AREA
238 SF
DEPUTY OFFICE
248 SF
DPM OFFICE
207 SF
EXEC OFFCR.
OFFICE
177 SF
KITCHEN
1. ALL EXISTING FURNITURE IN ROOMS 6078, 6079, 6080, 6083 AND 6085 SHALL
BE DISASSEMBLED, REMOVED AND DISPOSED OF BY THE CONTRACTOR.
2. EXISTING PRINTERS SHALL BE MOVED AND STORED ON-SITE DURING THE
REMOVAL OF EXISTING FURNITURE. CONTRACTOR SHALL RELOCATE
EXISTING PRINTERS AFTER FINAL FF&E INSTALL. COORDINATE LOCATIONS
WITH THE COR.
3. ALL FURNITURE IN WAITING AREA 6086 SHALL REMAIN.
4. APPROXIMATE FURNITURE LOCATIONS AND DIMENSION ARE SHOWN ON
PLANS WITH DASHED LINES. ALL EXISTING FF&E SHALL BE FIELD VERIFIED.
GENERAL NOTES
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
US Army Corps of Engineers
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
Plot Date: 3/17/2022 11:30:32 AM
IF400
C M
D S
U
IT
E
EX
IS
TI
N G
F F&
E
PL
AN
D es ig ne r
Au th or
C he ck er
1/4" = 1'-0"A1 COMMAND SUITE - EXISTING FF&E PLAN
EC
WKS
EC
WKS
EC
WKS
ARY
LE
E
405 SF
CMDR OFFICE
251 SF
ADMIN
870 SF
WAITING AREA
238 SF
DEPUTY OFFICE
248 SF
DPM OFFICE
207 SF
EXEC OFFCR.
OFFICE
177 SF
KITCHEN
D2
C1
C2
C2
C3 C3
C3
C3
C3
C3
C2
C2
C1
T4
C3 C3
C3 C3 C2
D3
C2
C2
D4 C1
S1
S4
S4
S4
C1
C3C3 C3
C3 C3 C3
C1
E1 E2
E1
E2 E2
E3
E1 S2
S3 D1
D1
A1
A1
S5
A3
A2
A2
A3
A3
A2
A2
A3
T1
C3 C3
A1 A1
C2 C2 T3
T3T2 T2
S4
S3
E1
A2
A3
D2
5' - 0"5' - 0"
IF402A7
D
EL
EV
AT
IO
N
EQ
EQ
2'
6"
EQ
EQ
7' - 6"
6'
0"
S6 CL
CL
E1
CL
CL
CL CL
CL
C3
1. REFER TO SPECIFICATION SECTION 12 51 00.00 23 FOR FULL FURNITURE
REQUIREMENTS.
2. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR INTEGRATED POWER
MODULES, A/V CONNECTIONS AND REQUIREMENTS. FURNITURE AND A/V
SHALL BE FULLY COORDINATED BY THE CONTRACTOR.
3. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR REQUIREMENTS OF
TVs.
4. ITEMS LISTED AS (NIC) ARE CONSIDERED NOT IN CONTRACT AND SHOWN
FOR COORDINATION PURPOSES ONLY.
GENERAL NOTES
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
US Army Corps of Engineers
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
Plot Date: 3/17/2022 11:30:42 AM
IF401
C M
D S
U
IT
E
FF
&E P
LA
N
D es ig ne r
Au th or
C he ck er
1/4" = 1'-0"A1 COMMAND SUITE FF&E PLAN
FF&E SCHEDULE
ITEM CODE DESCRIPTION
A1 GLASS MARKERBOARD
A2 DUAL MONITOR ARMS
A3 KEYBOARD TRAY
C1 TASK CHAIR
C2 UPHOLSTERED GUEST CHAIR
C3 CONFERENCE CHAIR
D1 EXECUTIVE DESK
D2 EXECUTIVE DESK
D3 EXECUTIVE DESK
D4 ADMIN DESK
E1 DESKTOP PRINTER (NIC)
E2 65" TV
E3 75" TV
S1 LATERAL FILE CREDENZA (72")
S2 CREDENZA SHELL (60")
S3 LATERAL FILE CREDENZA (60")
S4 TALL STORAGE CABINET (30")
S5 TALL WARDROBE (30")
S6 2-DRAWER LATERAL FILE
T1 EXECUTIVE CONFERENCE TABLE
T2 BULLET COLLABORATION TABLE
T3 SIDE TABLE
T4 RECTANGULAR COLLABORATION TABLE
FILE/FILE
BOX/BOX/
FILE
3' - 0"
6'
0"
2'
6" 3'
0"
3'
0" 3'
0"
6" OVERHANG
WIRE ACCESS
PANEL
FILE/FILE
CLOSED
SHELVING
WALL MOUNT OVERHEAD
OPEN
BELOW;
OPEN TO
WALL
HEIGHT ADJUSTABLE TABLE
W/ ENCLOSED LEG PANELS
8' - 0"
2'
6"
2' - 0"
FULL WARDROBE (RIGHT)
SHELVING (LEFT)
FURNITURE
POWER MODULE
POWER/USB/DATA
A/V INTEGRATED
POWER MODULE
WALL MOUNT OPEN
SHELVING ABOVE
TACKABLE FABRIC PANEL
BELOW OVERHEAD
WIRE ACCESS PANEL
BOX/BOX/FILE
OPEN BELOW;
OPEN TO
WALL
HEIGHT ADJUSTABLE TABLE
W/ ENCLOSED LEG PANELS
AND MODESTY PANEL
8' - 0"
3'
0"
2' - 0"
3'
6" 2'
6"
SLIDING DOOR WALL MOUNT OVERHEAD (78")
FULL WARDROBE (RIGHT)
SHELVING (LEFT)
A/V INTEGRATED
POWER MODULE
FURNITURE
POWER MODULE;
POWER/USB/DATA
TACKABLE FABRIC PANEL
BELOW OVERHEAD
BOX/BOX/FILE
BELOW WORKSURFACE
HEIGHT ADJUSTABLE
SWEEP TOP OR L-
SHAPED DESK SHELL W/
ENCLOSED ADJUSTABLE
LEG
5' - 6"
HINGE DOOR WALL
MOUNT OVERHEAD
(78")
FULL WARDROBE (RIGHT)
SHELVING (LEFT)
2' - 6"6' - 0"
LATERAL
FILE
A/V INTEGRATED
POWER MODULE
LOW HEIGHT CABINET
BELOW WORKSURFACE
WITH REMOVABLE
ACCESS PANELS
1' - 6"
OPEN BELOW; OPEN
TO WALL
2' - 6"
FURNITURE
POWER MODULE
POWER/ USB/ DATA
TACKABLE FABRIC PANEL
BELOW OVERHEAD
6'
4"
WIRE ACCESS
PANEL BELOW
BOX/BOX/FILE
OPEN BELOW
HEIGHT ADJUSTABLE TABLE
W/ ENCLOSED LEG PANELS
AND FULL MODESTY PANEL
6' - 0"
2'
6"
2' - 0"
3'
6" 1'
3"
HINGE DOOR WALL
MOUNT OVERHEAD
FULL WARDROBE
A/V INTERGATED
POWER MODULE
FURNITURE
POWER MODULE
POWER/USB/DATA
TACKABLE FABRIC PANEL
BELOW OVERHEAD
CLOSED
SHELVING
WIRE ACCESS
PANEL BEHIND
FILE/FILE
WARDROBE
WALL MOUNT OVERHEAD
OPEN BELOW
WALL MOUNT OPEN
SHELVING ABOVE
TACKABLE FABRIC
PANEL2'
1/ 2"
6'
0"3' - 0" 3' - 0"
6' - 0" 3' - 0"
SHALLOW DEPTH
SUPPORT LEG
2' - 6"
2'
0"
1. DRAWINGS, CONFIGURATIONS, COMPONENTS AND SPECIFICATIONS ARE
BASED ON THE USE OF A DESK BASED SYSTEM AND SHALL BE WOOD AND
VENEER CONSTRUCTION.
2. THE DESK BASED SYSTEM SHALL INCLUDE ALL NECESSARY CONNECTORS,
SUPPORT ARMS, END PANELS AND OTHER HARWARE NECESSARY TO
FORM A COMPLETE AND USABLE CONFIGURATION AS SHOWN ON THE
DRAWINGS.
3. DESKS, CHAIRS, STORAGE, TABLES AND ALL ANCILLARY FURNITURE SHALL
BE FROM THE SAME MANUFACTURER AND STYLE TO MATCH WITHIN EACH
SPACE.
4. DUE TO PRIOR DESIGN COORDINATION WITH THE LOCATION AND
POSITIONING OF ELECTRICAL AND DATA CONNECTIVITY POINTS IN THE
BUILDING, DESK LOCATIONS AND LAYOUTS SHALL NOT BE ALTERED. DESK
AND SUPPORTING PANELS SHALL BE OPEN OR PROVIDE A HINGE DOOR AT
LOCATIONS OF WALL OUTLETS AND DATA JACKS.
5. CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY
CONDITIONS TO ENSURE PROPER FIT OF ALL FURNITURE AS SHOWN ON
THE DRAWINGS. FURNITURE SHALL NOT OVERLAP OR OBSTRUCT DOOR
FRAMES, WALL LIGHT SWITCHES, THERMOSTATS, OR OTHER WALL
MOUNTED ITEMS.
6. ALL DESKS SHALL BE AS SHOWN ON THE PLANS, MIRRORED OR ROTATED
AS REQUIRED.
7. PEDESTAL CONFIGURATION SHALL BE AS SHOWN. FILE DRAWERS SHALL
INCLUDE HANGING BAR ACCESSORY. EACH PEDESTAL BOX DRAWER
SHALL INCLUDE A PENCIL TRAY.
8. WARDROBES SHALL BE DIVIDED IN HALF WITH TWO LOCKING SWING
DOORS; ONE SIDE SHALL CONTAIN SHELVING AND THE OTHER SIDE SHALL
BE FULLY OPEN WITH COAT ROD AND HOOK.
9. ALL WARDROBES, PEDESTALS, FILES, OVERHEAD STORAGE AND ANY
OTHER STORAGE COMPONENTS, SHALL INCLUDE THE STANDARD NUMBER
OF LOCKS AND LOCKING DEVICES. LOCKS SHALL BE KEYED ALIKE FOR
EACH OFFICE. EACH OFFICE SHALL BE PROVIDED THREE SETS OF KEYS.
10. ALL POWER MODULES SHALL BE FACTORY DRILLED.
11. REFER TO SPECIFICATION 27 41 00 FOR REQUIREMENTS OF THE
FURNITURE MOUNTED A/V INTEGRATED POWER MODULE.
12. FURNITURE POWER MODULE SHALL COME INSTALLED IN THE DESK
PROVIDED BY THE DESK MANUFACTURER AND SHALL CONTAIN A MINIMUM
CONFIGURATION OF TWO POWER OUTLETS, ONE DATA OUT JACK AND
TWO USB PORTS.
13. WIRE MANAGEMENT SHALL BE PROVIDED BELOW ALL WORKSURFACES.
14. ALL HEIGHT ADJUSTABLE DESKS SHALL HAVE A MODETY PANEL AS
INDICATED ON THE DRAWINGS.
15. ALL OVERHEADS SHALL BE WALL MOUNTED AND HAVE A TACKABLE
FABRIC WALL BOARD TO SPAN TO THE WORKSURFACE BELOW.
16. ALL WORKSURFACES, DOORS AND DRAWERS SHALL BE FINISHED WITH
WOOD VENEER AND MATCHING HARDWOOD EDGE.
17. ALL WORKSURFACES SHALL HAVE AN ADDITIONAL BAKED ON PROTECTIVE
FINISH ON THE WOOD.
18. MONITOR ARMS (A2) SHALL BE MOUNTED THROUGH GROMMET HOLE,
LOCATION SHALL BE COORDINATED W/ COR DURING INSTALLATION AND
FIELD DRILLED / INSTALLED.
SHEET NOTES
1. REFER TO SPECIFICATION SECTION 12 51 00.00 23 FOR FULL FURNITURE
REQUIREMENTS.
2. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR INTEGRATED POWER
MODULES, A/V CONNECTIONS AND REQUIREMENTS. FURNITURE AND A/V
SHALL BE FULLY COORDINATED BY THE CONTRACTOR.
3. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR REQUIREMENTS OF
TVs.
4. ITEMS LISTED AS (NIC) ARE CONSIDERED NOT IN CONTRACT AND SHOWN
FOR COORDINATION PURPOSES ONLY.
GENERAL NOTES
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
US Army Corps of Engineers
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
Plot Date: 3/17/2022 11:30:47 AM
IF402
EN
LA
R G
ED
D
ES
K
PL
AN
S
D es ig ne r
Au th or
C he ck er
3/4" = 1'-0"A1 ENLARGED D1
3/4" = 1'-0"A4 ENLARGED D2
3/4" = 1'-0"D4 ENLARGED D3
3/4" = 1'-0"E1 ENLARGED D4
1/2" = 1'-0"A7 D1 ELEVATION
TARY
405 SF
CMDR OFFICE
251 SF
ADMIN
870 SF
WAITING AREA
238 SF
DEPUTY OFFICE
248 SF
DPM OFFICE
207 SF
EXEC OFFCR.
OFFICE
6083 177 SF
KITCHEN
CL
1 QUAD WALL
RECEPTACLE, 2
DATA PORTS, AND
2 CATV OUTLET
(TV HEIGHT)
2 DATA PORTS AT
18", 1 POWER
DUPLEX AT 18",
JUNCTION BOXES
AT tv HEIGHT
DOWN TO 18" AND
INTO 2" CONDUIT
WITH HDMI, USB-C,
AND CAT6
CABLING.
SYMBOLS FOR
QUAD POWER,
TWO DATA
PORTS AND
HDMI/USB-
C/CAT6 PORTS IN
RECESSING
FLOOR BOX
(TYPICAL)
QUAD WALL
RECEPTACLE
AT DESK
(TYPICAL)
2 INCH
CONDUIT
WITH HDMI,
USB-C AND
CAT6
CABLING
(TYPICAL)
DATA AT 18", 1 POWER DUPLEX AT 18", 1
POWER DUPLEX AT TV HEIGHT, 1 DATA AT
TV HEIGHT, JUNCTION BOXES AT TV HEIGHT
DOWN TO 18"AND INTO 2" CONDUIT WITH
HDMI, USB-C AND CAT6 CABLING (TYPICAL)
1 QUAD WALL
RECEPTACLE, 2 DATA
PORTS AND 1 CATV
OUTLET (TV HEIGHT)
TWO DATA PORTS AT
18", 1 POWER DUPLEX AT
18", JUNCTION BOXES AT
TV HEIGHT DOWN TO 18"
AND INTO 2" CONDUIT
WITH HDMI, USB-C AND
CATV CABLING.
1. ALL BUILDING ELECTRICAL AND DATA WORK IS DONE BY OTHERS AND
SHALL BE CONSIDERED NOT IN CONTRACT. THIS PLAN IS PROVIDED FOR
INFORMATION ONLY.
2. CONTRACTOR SHALL BE REQUIRED TO CONNECT AND TEST ALL FF&E AND
A/V EQUIPMENT PER THE SPECIFICATIONS.
GENERAL NOTES
U .S
. A R
M Y
C O
R
PS
O F
EN
G
IN
EE
R S
US Army Corps of Engineers
SO
LI
C
IT
AT
IO
N N
O
D
ES
IG
N
ED
B
Y:
D
ES
C R
IP
TI
O N
A
M
AR
K
SI
ZE
SU
BM
IT
TE
D B
Y:
D
AT
E
C O
N
TR
AC
T
N O
C
H
EC
KE
D
B Y:
D R
AW
N
B Y:
IS
SU
E D
AT
E:
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
Plot Date: 3/17/2022 11:30:14 AM
E-401
EL
EC
TR
IC
AL
O
VE
R
VI
EW
D es ig ne r
Au th or
C he ck er
1/4" = 1'-0"A1 COMMAND SUITE ELECTRICAL FF&E
| CMD Suite Final2 - Sheet - IF400 - CMD SUITE EXISTING FF&E PLAN |
| Sheets |
| E-401 - ELECTRICAL OVERVIEW |
| IF400 - CMD SUITE EXISTING FF&E PLAN |
| IF401 - CMD SUITE FF&E PLAN |
| IF402 - ENLARGED DESK PLANS |
| CMD Suite Final2 - Sheet - IF401 - CMD SUITE FF&E PLAN |
| Sheets |
| E-401 - ELECTRICAL OVERVIEW |
| IF400 - CMD SUITE EXISTING FF&E PLAN |
| IF401 - CMD SUITE FF&E PLAN |
| IF402 - ENLARGED DESK PLANS |
| CMD Suite Final2 - Sheet - IF402 - ENLARGED DESK PLANS |
| Sheets |
| E-401 - ELECTRICAL OVERVIEW |
| IF400 - CMD SUITE EXISTING FF&E PLAN |
| IF401 - CMD SUITE FF&E PLAN |
| IF402 - ENLARGED DESK PLANS |
| CMD Suite Final2 - Sheet - E-401 - ELECTRICAL OVERVIEW |
| Sheets |
| E-401 - ELECTRICAL OVERVIEW |
| IF400 - CMD SUITE EXISTING FF&E PLAN |
| IF401 - CMD SUITE FF&E PLAN |
| IF402 - ENLARGED DESK PLANS |