405 SF

CMDR OFFICE

251 SF

ADMIN

870 SF

WAITING AREA

238 SF

DEPUTY OFFICE

248 SF

DPM OFFICE

207 SF

EXEC OFFCR.

OFFICE

177 SF

KITCHEN

1. ALL EXISTING FURNITURE IN ROOMS 6078, 6079, 6080, 6083 AND 6085 SHALL

BE DISASSEMBLED, REMOVED AND DISPOSED OF BY THE CONTRACTOR.

2. EXISTING PRINTERS SHALL BE MOVED AND STORED ON-SITE DURING THE

REMOVAL OF EXISTING FURNITURE. CONTRACTOR SHALL RELOCATE

EXISTING PRINTERS AFTER FINAL FF&E INSTALL. COORDINATE LOCATIONS

WITH THE COR.

3. ALL FURNITURE IN WAITING AREA 6086 SHALL REMAIN.

4. APPROXIMATE FURNITURE LOCATIONS AND DIMENSION ARE SHOWN ON

PLANS WITH DASHED LINES. ALL EXISTING FF&E SHALL BE FIELD VERIFIED.

GENERAL NOTES

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

US Army Corps of Engineers

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

Plot Date: 3/17/2022 11:30:32 AM

IF400

C M

D S

U

IT

E

EX

IS

TI

N G

F F&

E

PL

AN

D es ig ne r

Au th or

C he ck er

1/4" = 1'-0"A1 COMMAND SUITE - EXISTING FF&E PLAN

EC

WKS

EC

WKS

EC

WKS

ARY

LE

E

405 SF

CMDR OFFICE

251 SF

ADMIN

870 SF

WAITING AREA

238 SF

DEPUTY OFFICE

248 SF

DPM OFFICE

207 SF

EXEC OFFCR.

OFFICE

177 SF

KITCHEN

D2

C1

C2

C2

C3 C3

C3

C3

C3

C3

C2

C2

C1

T4

C3 C3

C3 C3 C2

D3

C2

C2

D4 C1

S1

S4

S4

S4

C1

C3C3 C3

C3 C3 C3

C1

E1 E2

E1

E2 E2

E3

E1 S2

S3 D1

D1

A1

A1

S5

A3

A2

A2

A3

A3

A2

A2

A3

T1

C3 C3

A1 A1

C2 C2 T3

T3T2 T2

S4

S3

E1

A2

A3

D2

5' - 0"5' - 0"

IF402A7

D

EL

EV

AT

IO

N

EQ

EQ

2'

6"

EQ

EQ

7' - 6"

6'

0"

S6 CL

CL

E1

CL

CL

CL CL

CL

C3

1. REFER TO SPECIFICATION SECTION 12 51 00.00 23 FOR FULL FURNITURE

REQUIREMENTS.

2. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR INTEGRATED POWER

MODULES, A/V CONNECTIONS AND REQUIREMENTS. FURNITURE AND A/V

SHALL BE FULLY COORDINATED BY THE CONTRACTOR.

3. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR REQUIREMENTS OF

TVs.

4. ITEMS LISTED AS (NIC) ARE CONSIDERED NOT IN CONTRACT AND SHOWN

FOR COORDINATION PURPOSES ONLY.

GENERAL NOTES

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

US Army Corps of Engineers

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

Plot Date: 3/17/2022 11:30:42 AM

IF401

C M

D S

U

IT

E

FF

&E P

LA

N

D es ig ne r

Au th or

C he ck er

1/4" = 1'-0"A1 COMMAND SUITE FF&E PLAN

FF&E SCHEDULE

ITEM CODE DESCRIPTION

A1 GLASS MARKERBOARD

A2 DUAL MONITOR ARMS

A3 KEYBOARD TRAY

C1 TASK CHAIR

C2 UPHOLSTERED GUEST CHAIR

C3 CONFERENCE CHAIR

D1 EXECUTIVE DESK

D2 EXECUTIVE DESK

D3 EXECUTIVE DESK

D4 ADMIN DESK

E1 DESKTOP PRINTER (NIC)

E2 65" TV

E3 75" TV

S1 LATERAL FILE CREDENZA (72")

S2 CREDENZA SHELL (60")

S3 LATERAL FILE CREDENZA (60")

S4 TALL STORAGE CABINET (30")

S5 TALL WARDROBE (30")

S6 2-DRAWER LATERAL FILE

T1 EXECUTIVE CONFERENCE TABLE

T2 BULLET COLLABORATION TABLE

T3 SIDE TABLE

T4 RECTANGULAR COLLABORATION TABLE

FILE/FILE

BOX/BOX/

FILE

3' - 0"

6'

0"

2'

6" 3'

0"

3'

0" 3'

0"

6" OVERHANG

WIRE ACCESS

PANEL

FILE/FILE

CLOSED

SHELVING

WALL MOUNT OVERHEAD

OPEN

BELOW;

OPEN TO

WALL

HEIGHT ADJUSTABLE TABLE

W/ ENCLOSED LEG PANELS

8' - 0"

2'

6"

2' - 0"

FULL WARDROBE (RIGHT)

SHELVING (LEFT)

FURNITURE

POWER MODULE

POWER/USB/DATA

A/V INTEGRATED

POWER MODULE

WALL MOUNT OPEN

SHELVING ABOVE

TACKABLE FABRIC PANEL

BELOW OVERHEAD

WIRE ACCESS PANEL

BOX/BOX/FILE

OPEN BELOW;

OPEN TO

WALL

HEIGHT ADJUSTABLE TABLE

W/ ENCLOSED LEG PANELS

AND MODESTY PANEL

8' - 0"

3'

0"

2' - 0"

3'

6" 2'

6"

SLIDING DOOR WALL MOUNT OVERHEAD (78")

FULL WARDROBE (RIGHT)

SHELVING (LEFT)

A/V INTEGRATED

POWER MODULE

FURNITURE

POWER MODULE;

POWER/USB/DATA

TACKABLE FABRIC PANEL

BELOW OVERHEAD

BOX/BOX/FILE

BELOW WORKSURFACE

HEIGHT ADJUSTABLE

SWEEP TOP OR L-

SHAPED DESK SHELL W/

ENCLOSED ADJUSTABLE

LEG

5' - 6"

HINGE DOOR WALL

MOUNT OVERHEAD

(78")

FULL WARDROBE (RIGHT)

SHELVING (LEFT)

2' - 6"6' - 0"

LATERAL

FILE

A/V INTEGRATED

POWER MODULE

LOW HEIGHT CABINET

BELOW WORKSURFACE

WITH REMOVABLE

ACCESS PANELS

1' - 6"

OPEN BELOW; OPEN

TO WALL

2' - 6"

FURNITURE

POWER MODULE

POWER/ USB/ DATA

TACKABLE FABRIC PANEL

BELOW OVERHEAD

6'

4"

WIRE ACCESS

PANEL BELOW

BOX/BOX/FILE

OPEN BELOW

HEIGHT ADJUSTABLE TABLE

W/ ENCLOSED LEG PANELS

AND FULL MODESTY PANEL

6' - 0"

2'

6"

2' - 0"

3'

6" 1'

3"

HINGE DOOR WALL

MOUNT OVERHEAD

FULL WARDROBE

A/V INTERGATED

POWER MODULE

FURNITURE

POWER MODULE

POWER/USB/DATA

TACKABLE FABRIC PANEL

BELOW OVERHEAD

CLOSED

SHELVING

WIRE ACCESS

PANEL BEHIND

FILE/FILE

WARDROBE

WALL MOUNT OVERHEAD

OPEN BELOW

WALL MOUNT OPEN

SHELVING ABOVE

TACKABLE FABRIC

PANEL2'

1/ 2"

6'

0"3' - 0" 3' - 0"

6' - 0" 3' - 0"

SHALLOW DEPTH

SUPPORT LEG

2' - 6"

2'

0"

1. DRAWINGS, CONFIGURATIONS, COMPONENTS AND SPECIFICATIONS ARE

BASED ON THE USE OF A DESK BASED SYSTEM AND SHALL BE WOOD AND

VENEER CONSTRUCTION.

2. THE DESK BASED SYSTEM SHALL INCLUDE ALL NECESSARY CONNECTORS,

SUPPORT ARMS, END PANELS AND OTHER HARWARE NECESSARY TO

FORM A COMPLETE AND USABLE CONFIGURATION AS SHOWN ON THE

DRAWINGS.

3. DESKS, CHAIRS, STORAGE, TABLES AND ALL ANCILLARY FURNITURE SHALL

BE FROM THE SAME MANUFACTURER AND STYLE TO MATCH WITHIN EACH

SPACE.

4. DUE TO PRIOR DESIGN COORDINATION WITH THE LOCATION AND

POSITIONING OF ELECTRICAL AND DATA CONNECTIVITY POINTS IN THE

BUILDING, DESK LOCATIONS AND LAYOUTS SHALL NOT BE ALTERED. DESK

AND SUPPORTING PANELS SHALL BE OPEN OR PROVIDE A HINGE DOOR AT

LOCATIONS OF WALL OUTLETS AND DATA JACKS.

5. CONTRACTOR SHALL TAKE FIELD MEASUREMENTS AND VERIFY

CONDITIONS TO ENSURE PROPER FIT OF ALL FURNITURE AS SHOWN ON

THE DRAWINGS. FURNITURE SHALL NOT OVERLAP OR OBSTRUCT DOOR

FRAMES, WALL LIGHT SWITCHES, THERMOSTATS, OR OTHER WALL

MOUNTED ITEMS.

6. ALL DESKS SHALL BE AS SHOWN ON THE PLANS, MIRRORED OR ROTATED

AS REQUIRED.

7. PEDESTAL CONFIGURATION SHALL BE AS SHOWN. FILE DRAWERS SHALL

INCLUDE HANGING BAR ACCESSORY. EACH PEDESTAL BOX DRAWER

SHALL INCLUDE A PENCIL TRAY.

8. WARDROBES SHALL BE DIVIDED IN HALF WITH TWO LOCKING SWING

DOORS; ONE SIDE SHALL CONTAIN SHELVING AND THE OTHER SIDE SHALL

BE FULLY OPEN WITH COAT ROD AND HOOK.

9. ALL WARDROBES, PEDESTALS, FILES, OVERHEAD STORAGE AND ANY

OTHER STORAGE COMPONENTS, SHALL INCLUDE THE STANDARD NUMBER

OF LOCKS AND LOCKING DEVICES. LOCKS SHALL BE KEYED ALIKE FOR

EACH OFFICE. EACH OFFICE SHALL BE PROVIDED THREE SETS OF KEYS.

10. ALL POWER MODULES SHALL BE FACTORY DRILLED.

11. REFER TO SPECIFICATION 27 41 00 FOR REQUIREMENTS OF THE

FURNITURE MOUNTED A/V INTEGRATED POWER MODULE.

12. FURNITURE POWER MODULE SHALL COME INSTALLED IN THE DESK

PROVIDED BY THE DESK MANUFACTURER AND SHALL CONTAIN A MINIMUM

CONFIGURATION OF TWO POWER OUTLETS, ONE DATA OUT JACK AND

TWO USB PORTS.

13. WIRE MANAGEMENT SHALL BE PROVIDED BELOW ALL WORKSURFACES.

14. ALL HEIGHT ADJUSTABLE DESKS SHALL HAVE A MODETY PANEL AS

INDICATED ON THE DRAWINGS.

15. ALL OVERHEADS SHALL BE WALL MOUNTED AND HAVE A TACKABLE

FABRIC WALL BOARD TO SPAN TO THE WORKSURFACE BELOW.

16. ALL WORKSURFACES, DOORS AND DRAWERS SHALL BE FINISHED WITH

WOOD VENEER AND MATCHING HARDWOOD EDGE.

17. ALL WORKSURFACES SHALL HAVE AN ADDITIONAL BAKED ON PROTECTIVE

FINISH ON THE WOOD.

18. MONITOR ARMS (A2) SHALL BE MOUNTED THROUGH GROMMET HOLE,

LOCATION SHALL BE COORDINATED W/ COR DURING INSTALLATION AND

FIELD DRILLED / INSTALLED.

SHEET NOTES

1. REFER TO SPECIFICATION SECTION 12 51 00.00 23 FOR FULL FURNITURE

REQUIREMENTS.

2. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR INTEGRATED POWER

MODULES, A/V CONNECTIONS AND REQUIREMENTS. FURNITURE AND A/V

SHALL BE FULLY COORDINATED BY THE CONTRACTOR.

3. REFER TO SPECIFICATION 27 41 00 A/V SCOPE FOR REQUIREMENTS OF

TVs.

4. ITEMS LISTED AS (NIC) ARE CONSIDERED NOT IN CONTRACT AND SHOWN

FOR COORDINATION PURPOSES ONLY.

GENERAL NOTES

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

US Army Corps of Engineers

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

Plot Date: 3/17/2022 11:30:47 AM

IF402

EN

LA

R G

ED

D

ES

K

PL

AN

S

D es ig ne r

Au th or

C he ck er

3/4" = 1'-0"A1 ENLARGED D1

3/4" = 1'-0"A4 ENLARGED D2

3/4" = 1'-0"D4 ENLARGED D3

3/4" = 1'-0"E1 ENLARGED D4

1/2" = 1'-0"A7 D1 ELEVATION

TARY

405 SF

CMDR OFFICE

251 SF

ADMIN

870 SF

WAITING AREA

238 SF

DEPUTY OFFICE

248 SF

DPM OFFICE

207 SF

EXEC OFFCR.

OFFICE

6083 177 SF

KITCHEN

CL

1 QUAD WALL

RECEPTACLE, 2

DATA PORTS, AND

2 CATV OUTLET

(TV HEIGHT)

2 DATA PORTS AT

18", 1 POWER

DUPLEX AT 18",

JUNCTION BOXES

AT tv HEIGHT

DOWN TO 18" AND

INTO 2" CONDUIT

WITH HDMI, USB-C,

AND CAT6

CABLING.

SYMBOLS FOR

QUAD POWER,

TWO DATA

PORTS AND

HDMI/USB-

C/CAT6 PORTS IN

RECESSING

FLOOR BOX

(TYPICAL)

QUAD WALL

RECEPTACLE

AT DESK

(TYPICAL)

2 INCH

CONDUIT

WITH HDMI,

USB-C AND

CAT6

CABLING

(TYPICAL)

DATA AT 18", 1 POWER DUPLEX AT 18", 1

POWER DUPLEX AT TV HEIGHT, 1 DATA AT

TV HEIGHT, JUNCTION BOXES AT TV HEIGHT

DOWN TO 18"AND INTO 2" CONDUIT WITH

HDMI, USB-C AND CAT6 CABLING (TYPICAL)

1 QUAD WALL

RECEPTACLE, 2 DATA

PORTS AND 1 CATV

OUTLET (TV HEIGHT)

TWO DATA PORTS AT

18", 1 POWER DUPLEX AT

18", JUNCTION BOXES AT

TV HEIGHT DOWN TO 18"

AND INTO 2" CONDUIT

WITH HDMI, USB-C AND

CATV CABLING.

1. ALL BUILDING ELECTRICAL AND DATA WORK IS DONE BY OTHERS AND

SHALL BE CONSIDERED NOT IN CONTRACT. THIS PLAN IS PROVIDED FOR

INFORMATION ONLY.

2. CONTRACTOR SHALL BE REQUIRED TO CONNECT AND TEST ALL FF&E AND

A/V EQUIPMENT PER THE SPECIFICATIONS.

GENERAL NOTES

U .S

. A R

M Y

C O

R

PS

O F

EN

G

IN

EE

R S

US Army Corps of Engineers

SO

LI

C

IT

AT

IO

N N

O

D

ES

IG

N

ED

B

Y:

D

ES

C R

IP

TI

O N

A

M

AR

K

SI

ZE

SU

BM

IT

TE

D B

Y:

D

AT

E

C O

N

TR

AC

T

N O

C

H

EC

KE

D

B Y:

D R

AW

N

B Y:

IS

SU

E D

AT

E:

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

Plot Date: 3/17/2022 11:30:14 AM

E-401

EL

EC

TR

IC

AL

O

VE

R

VI

EW

D es ig ne r

Au th or

C he ck er

1/4" = 1'-0"A1 COMMAND SUITE ELECTRICAL FF&E

CMD Suite Final2 - Sheet - IF400 - CMD SUITE EXISTING FF&E PLAN
Sheets
E-401 - ELECTRICAL OVERVIEW
IF400 - CMD SUITE EXISTING FF&E PLAN
IF401 - CMD SUITE FF&E PLAN
IF402 - ENLARGED DESK PLANS
CMD Suite Final2 - Sheet - IF401 - CMD SUITE FF&E PLAN
Sheets
E-401 - ELECTRICAL OVERVIEW
IF400 - CMD SUITE EXISTING FF&E PLAN
IF401 - CMD SUITE FF&E PLAN
IF402 - ENLARGED DESK PLANS
CMD Suite Final2 - Sheet - IF402 - ENLARGED DESK PLANS
Sheets
E-401 - ELECTRICAL OVERVIEW
IF400 - CMD SUITE EXISTING FF&E PLAN
IF401 - CMD SUITE FF&E PLAN
IF402 - ENLARGED DESK PLANS
CMD Suite Final2 - Sheet - E-401 - ELECTRICAL OVERVIEW
Sheets
E-401 - ELECTRICAL OVERVIEW
IF400 - CMD SUITE EXISTING FF&E PLAN
IF401 - CMD SUITE FF&E PLAN
IF402 - ENLARGED DESK PLANS