This file is a Questions and Answers (Q&A) document containing vendor inquiries and government responses related to the solicitation for Exterior Cipher Locks and Exit Hardware Retrofit at Building 768, Hawaii. The Q&A document addresses clarifications submitted by potential offerors regarding technical specifications, product requirements, delivery schedules, and other solicitation details. These responses are incorporated into amendment W912CN27QA0100001 to the original solicitation W912CN27QA010, issued by the Department of the Army Materiel Command Army Contracting Command. Offerors are required to acknowledge receipt of this amendment with their quotation submission.

The specific questions and answers contained within this document provide guidance on acceptable products, installation requirements, compliance standards, and other technical or administrative aspects of the retrofit project. As a Q&A document, it serves to clarify ambiguities in the solicitation documents and ensure all potential vendors have consistent information for preparing their bids or quotations for this facility upgrade requirement.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Sheet1

QuestionAnswer
1Vertical Rod Assemblies: The SOW identifies 12 exit doors but requires 20 vertical rod assemblies.
Please confirm the exact quantity and configuration.The exact configuration requires 20 vertical rod assemblies across the designated exit doors.

This is due to several double-door (two-leaf) openings where both leaves require surface-mounted or concealed vertical rod panic hardware to comply with life-safety egress standards (NFPA 101 / UFC 1-200-01) while maintaining secure top-and-bottom latching. Single doors require 1 vertical rod assembly each. A detailed opening-by-opening breakdown is provided in the updated Door Hardware Schedule 2 Bullet-Resistant Doors: Can you provide door dimensions, thicknesses, existing hardware details, and drawings for the nine bullet-resistant openings bullet-resistant openings must meet UL 752 Level 3 (handgun protection) or Level 8 (rifle protection) as specified by the physical security plan for this facility type.

3Conversion Plates: Please confirm the required quantities and allocation of
standard and custom dress plates.custom conversion plates for bullet resistent doors 131,129a,149,129b,129c,131b,131c,117,101 entry/
4SFIC Cores: Please confirm the required quantity, keyway, and master-keying
specifications.2
5Technician Certification: What specific GSA certification or credentials
are required for installation personnel?N/A
6Deliverables: The SOW references DEL-01 through DEL-09,
but only DEL-01 through DEL-05 are listed. Could you provide the missing deliverables?DEL-06: Key Control Plan & Key Bitting List (delivered securely).

DEL-07: Manufacturer Product Data Sheets & UL/GSA Certifications.

DEL-08: Operations & Maintenance (O&M) Manuals and Spare Parts Inventory List.

DEL-09: As-Built Drawings & Contractor Warranty Certificate (minimum 1-year workmanship/materials).

8Are panic bars required on all doors fitted with the locks specified under Items
2 and 4?yes. In accordance with UFC 1-200-01 (DoD Building Code) and NFPA 101 (Life Safety Code), panic hardware is mandatory on all high-occupancy or emergency egress doors. Where GSA-approved locks (Item 2) or SFIC auxiliary locks (Item 4) are installed on exit-only or emergency doors, they must be fully integrated with fire-rated panic hardware/exit devices to guarantee single-motion egress.
9If so, is the difference between the 20 panic bars and 17 locks due to double-door openings where both leaves require panic bars, but only one leaf requires a lock?Yes, your assumption is correct. The difference is due to double-door (two-leaf) openings. For these openings, both leaves require panic bars (totaling 20 panic bars) to meet emergency egress standards, but only the active leaf requires an operational lock cylinder/mechanism (totaling 17 locks) while the inactive leaf is secured via the vertical rod assembly.
10Confirm whether battery-free/self-powered operation applies only to the 12 exit-device locks or to all 17 locks. Confirm the required configuration for the five mortise locks and whether external wiring, access-control-panel connection, network connectivity, or replaceable batteries are permitted.All battery free
11Door 101 appears in both the standard mortise group and the bullet-resistant door group. Should Door 101 receive standard or BR conversion plates, and should the standard conversion plate quantity be four or five?Door convertsion wrap to cylindrical latch reinforcement adapter
12Can the Government provide the required SFIC core quantity and keying schedule? Will the new cores be tied into an existing DPW master key system, and if so, will DPW furnish the keying schedule? or must the contractor establish a new keying configuration?US property and do not duplicate- keys will be turned into DPW where unit can sign them out
13NAICS 238290 is identified along with PSC 5340. Does the Government anticipate issuing the resulting solicitation as a construction, service, or supply acquisition?NAICS code is 423710 IAW solicitation and this is supply acquisition with

incidental installation services.

14Are any of the affected openings fire-rated, and will Federal Fire or another AHJ be required to review or approve the proposed egress hardware before acceptance?NA
15Provide or confirm base-access procedures; vehicle/personnel processing; work hours; escort/badging/device restrictions; end-of-day door security; site-visit procedures; photography rules; Hawaii contractor/locksmith licensing; additional credentials; custom-hardware approval process and review time; and how Government-caused access/approval delays affect the 30-day performance period.Only need driver liscense insurance on vic no criminal record and m-f 0900-1700
16Does the Government anticipate requiring any additional submittals, product data, or closeout deliverables beyond those identified in the presolicitation?No additional submittals, product data, or closeout deliverables are currently

anticipated beyond those identified in the solicitation and its attachments.

17 Please confirm whether FAR 52.219-14 applies to this acquisition. FAR 52.219-14 applies to small business set-asides expected to exceed SAT.

Because this requirement is valued below SAT, FAR 52.219-14 does not apply.

18Does the Government classify the requirement as a supply acquisition with incidental installation, or as an installation/service requirement for purposes of applicable subcontracting limitations?This requirement is classified as supply acquisition with incidental installation services.
19Does the nonmanufacturer rule apply to this acquisition, and if so, has any applicable waiver been issued?No, it does not apply to Small Business Set-Asides valued below SAT.
20Are there any additional restrictions on a qualifying small-business prime contractor using a qualified subcontractor to furnish and install the required hardware?Again because this is below SAT, limitations articulated in FAR 52.219-14 do not apply.

However, prime contractor remains fully responsible to contract administration, quality assurance, warranty enforcement, and ensuring all installation personnel meet the technical certification, proficiencies, and base-access requirements of the solicitation.

21Must each technician performing installation, core pinning, and exit-device alignment independently hold the required certification?Yes anyone who is installing must have their cert to install locks
22Is manufacturer training or authorization required in addition to GSA qualification, and what documentation will satisfy both requirements?No
23Please identify the applicable DoD approval standard or approved-products listing for the required 10-PIN cipher locks.GSA certifief locks installation
24Please confirm whether any particular manufacturer, product family, or model is mandatory, or whether technically equivalent products are acceptable.NA
25The technical attachment contains editing comments concerning brand-specific hardware and technical descriptions. Will the Government provide a finalized, clean attachment confirming the controlling specifications?No
26Are any additional key-control, restricted-keyway, or manufacturer requirements applicable beyond those expressly identified in the attachment?No
27The attachment requires a two-year warranty and references emergency and non-emergency service-level agreements, but does not specify response deadlines.
Please provide the required response and corrective-action times for each service category, including any mandatory on-site support requirements.See updated Salient Characteristics
28Please confirm whether any project-specific minimum insurance coverage or bonding requirements apply.Offerors are not required to submit additional bonding or insurance documentation with their quotations. Contractors remain responsible for complying with applicable Federal, State, and local laws and regulations, including applicable workers’ compensation requirements.
29Section B identifies Building 768 as the installation location, while Sections E and F reference Building 1492 at 131 Fleck Place. Please confirm that Building 768 is the sole installation location and clarify the purpose of the Building 1492 address.Place of Performance is Bldg. 768 only
30Please clarify the applicable domestic-origin requirements for the proposed locksets, exit devices, and associated components, including how the cited FAR and DFARS provisions are intended to apply to this acquisition.Domestic-origin requirements apply to this requirement. The applicable FAR and DFARS provisions and clauses have been updated in the solicitation. Offerors shall review the amended solicitation and complete all required representations and certifications.
31Does the Government anticipate providing covered defense information requiring safeguarding under DFARS 252.204-7012?The Government does not currently anticipate providing covered defense information under this requirement. If such information becomes necessary, it will be provided through authorized channels, and DFARS 252.204-7012 will apply.
32Are any solicitation-specific cybersecurity assessments, representations, or documentation required with the quotation beyond the provisions expressly identified?No additional solicitation-specific cybersecurity assessment or documentation is required with the quotation.
33The solicitation includes the HUBZone price evaluation preference provision while identifying the acquisition as a total small-business set-aside.
Please confirm whether FAR 52.219-4 is intended to apply or whether the Government anticipates correcting the provision.This acquisition is a total small-business set-aside. FAR 52.219-4, Notice of Price Evaluation Preference for HUBZone Small Business Concerns, does not apply. Please refer to the amended solicitation.
34Lock type. Unit representatives at the site visit stated a preference for mechanical pushbutton locks with a key override and no batteries or electronics. The draft requires a standalone electronic pushbutton lock without replaceable batteries. Which does the Government require, and will the solicitation be revised to match? For the Government's information, manufacturer data for the common mechanical pushbutton exit trim states that it cannot operate vertical rod exit devices. If mechanical locks are required, may rim exit devices replace the vertical rod devices?No
35"10-PIN." Please define this term. Does it mean a ten-button keypad, a code length, or something else? Mechanical pushbutton locks commonly have five buttons.10button keypad
36Ballistic items. The doors listed as bullet-resistant measure approximately 4-1/4 to 4-3/4 inches thick, and we found no rating labels. The unit stated that ballistic protection is not a current requirement. Must the new hardware preserve a ballistic rating? If yes, please provide the required rating and door manufacturer. If no, will the Government delete the 18 custom bullet-resistant plates and allow standard dress plates? Extended tailpieces will be needed in either case because of the door thickness.We are not sure, but if level 3, lowest level we will go with
37Exit device count. Doors 117 and 149 currently have mortise locks and no exit devices.
Door 129B has a rim exit device without vertical rods. Should these three openings receive vertical rod exit devices? Please confirm the total number of openings requiring exit devices and the basis for the quantity of 20 vertical locking bars.Yes
38Door closers. The closers on the aluminum doors are mounted on the exterior face and are exposed to weather and tampering. Does the Government want these relocated to the interior or replaced under this requirement? The draft does not address door closers. If this work is required, please add the appropriate line item and quantity.No
39Door 101. Door 101 Entry appears in both the standard and bullet-resistant groups. Which requirement applies to this opening, and is the standard plate quantity four or five?Bullet-resistant openings must meet UL 752 Level 3 (handgun protection) or

Level 8 (rifle protection) as specified by the physical security plan for this facility type.

40Technician certification. Our understanding is that GSA technician certification applies to GSA-approved security containers, vault doors, and their combination locks rather than pushbutton door locks. Will the Government remove this requirement or identify the specific technician credential or certification it will accept for this work?Just a lock smith that is GSA certified
41Keying. Will the new cores tie into an existing DPW key system, and who will furnish the required keyway and keying schedule?DPW
42Removed hardware. The existing locks are battery powered. Are removed locks, cores, exit devices, closers, batteries, and other associated hardware to be turned over to the Government, or should they be disposed of by the contractor?disposed of by contractors
43Schedule. What are the anticipated quote due date and period of performance?See Solicitation.
44Will exterior and interior mounted door closers need to be replaced? Would recommend the exterior closer holes be plugged and the closer be mounted on the interior side of the door? Also recommend a heavy duty grade 1 US made closer be used. The closers may require a drop plate for mounting.Not replaced but holes to be plugged
45There are 2 single door aluminum glass doors that have mortise type lockset on them without a panic exit device on the interior side of the door. Since the interior space of the this door will potentially have 50 people or more inside the interior space I would recommend that a panic exit device be added to the door.
Will the addition of this panic exit.device be required?it can be added
46The non standard door thickness of several of these doors may require non standard lead time to order parts. It was mentioned that this project is to be completed before January 1st, 2027 due to an inspection deadline that the customer is trying to meet. When is the inspection date that we are planning to complete this job in time for?We can extend the timeline of it to be completed if there is a timeline for ordering/ deievery timeline so it is not stretched out