FBO-IJO#06-0382, UPGRADE FIRE ALARM SYSTEM, BLDG 1001 Unit.xls

XLS spreadsheet 35 KB Posted

Attached to
Fire Alarm, Building 1001, JOR 06-0382.
Solicitation number
W912CF-09-B-0003
Issued by

About this file

FBO-IJO#06-0382, UPGRADE FIRE ALARM SYSTEM, BLDG 1001 Unit.xls

View the file

Other files

File Type Posted
BidAbstract09B0003.pdf PDF
1001f0602A1.pdf PDF
1001f0601A1.pdf PDF
1001 FAS ADDENDUM 1.doc DOC document
W912CF09B0003-P00003 FIRE JOR 06-0382 B1001.doc DOC document
W912CF09B0003-P00002 FIRE JOR 06-0382 B1001.doc DOC document
Bid Opening-Eatontown Library--09B0003.doc DOC document
W912CF09B0003-P00001 FIRE JOR 06-0382 B1001.doc DOC document
SiteVisitFtMonmouth--09B0003.doc DOC document
W912CF09B0003 FIRE JOR 06-0382 B1001.doc DOC document
1001f0601.pdf PDF
1001f0602.pdf PDF
Show all 12

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Unit Costs

CostWorks 2007 - IJO#06-0383,UPGRADE FIRE ALARM SYSTEM, BLDG 1001
QtyCSI NumberDescriptionCrewDaily OutputLabor HoursUnitBare Mat.Bare LaborBare Equip.TotalTotal Incl. O&PZip Code PrefixTypeReleaseNote
21.00028314 650 5200Detection Systems, heat detector, smoke detector, ceiling type, excl. wires & conduit (REMOVAL)1 Elec6.21.29Ea.077Union2007U911912
2.00028312 350 7000Detection Systems, break glass station, excl. wires & conduit (REMOVAL)1 Elec81Ea.077Union2007U912092
3.00028312 350 5600Detection Systems, strobe & horn, excl. wires & conduit (REMOVAL)1 Elec5.31.509Ea.077Union2007U911992
0.00028312 350 4000Detection Systems, fire alarm control panel, 12 zone, excl. wires & conduit (REMOVAL)2 Elec0.6723.988Ea.077Union2007U911732
0.00026052 320 1600Fire alarm cable, FEP teflon, 150 volt, to 200 Deg.C, #22, 2 pair (REMOVAL)1 Elec81C.L.F.077Union2007U828982
0.00026051 990 1200Wire, copper, stranded, 600 volt, #12, type THWN-THHN, in raceway (REMOVAL)1 Elec110.727C.L.F.077Union2007U831442
15.16026051 990 1000Wire, copper, stranded, 600 volt, #14, type THWN-THHN, in raceway (REMOVAL)1 Elec130.615C.L.F.077Union2007U831402
587.00026053 305 5020Electric metallic tubing (EMT), 3/4" diameter, to 15' high, incl 2 terminations, 2 elbows & 11 beam clamps per 100 LF1 Elec1300.062L.F.077Union2007U831402
6.00028312 350 7010Detection Systems, break glass station, addressable, excl. wires & conduit1 Elec7.251.103Ea.077Union2007U912112
9.00028312 350 5610Detection Systems, strobe & horn, ADA type, excl. wires & conduit1 Elec5.31.509Ea.077Union2007U912002
7.00028312 350 5620Detection Systems, visual alarm, ADA type, excl. wires & conduit1 Elec6.71.194Ea.077Union2007U912012
8.00028314 350 5010Detection Systems, signal bell for fire alarm, detector, heat (addressable type), excl. wires & conduit1 Elec7.251.103Ea.077Union2007U911872
37.00028314 650 5240Detection Systems, smoke detector, addressable type, excl. wires & conduit1 Elec61.333Ea.077Union2007U911962
6.00028314 650 5420Detection Systems, smoke detector, duct type, addressable, excl. wires & conduit1 Elec3.22.5Ea.077Union2007U911982
4.00028312 350 4050Detection Systems, fire alarm control panel, actuating device, excl. wires & conduit1 Elec81Ea.
1.00028312 350 8000Detection Systems, remote annunciator, 12 zone lamp, excl. wires & conduit (LCD-160)2 Elec2.66.154Ea.
0.00028312 350 4175Detection Systems, fire alarm control panel, addressable interface device, excl. wires & conduit1 Elec5.31.509Ea.
0.00028312 350 4160Detection Systems, fire alarm control panel, addressable without voice, up to 200 points, excl. wires & conduit2 Elec1.1413.998Ea.077Union2007U911772
28.00031231 614 5300Excavating, 18" pipe, hand excavate and trim for pipe bells after trench excavation, includes excavation and backfill1 Clab1300.062L.F.077Union2007U967232
55.00026053 305 1800Rigid galvanized steel conduit, 1" diameter, to 15' H, incl 2 terminations, 2 elbows & 11 beam clamps per 100 LF1 Elec650.123L.F.077Union2007U800202
220.00026053 305 1770Rigid galvanized steel conduit, 3/4" diameter, to 15' H, incl 2 terminations, 2 elbows & 11 beam clamps per 100 LF1 Elec800.1L.F.077Union2007U800192
220.00026053 305 5020Electric metallic tubing (EMT), 3/4" diameter, to 15' high, incl 2 terminations, 2 elbows & 11 beam clamps per 100 LF1 Elec1300.062L.F.077Union2007U801322
70.00026053 305 5040Electric metallic tubing (EMT), 1" diameter, to 15' high, incl 2 terminations, 2 elbows & 11 beam clamps per 100 LF1 Elec1150.07L.F.077Union2007U801352
9.28026052 320 1850Fire alarm cable, FEP teflon, 150 volt, to 200 Deg.C, #18, 1 pair (for #16 detection circuits)1 Elec81C.L.F.077Union2007U829032
5.15026052 320 1850Fire alarm cable, FEP teflon, 150 volt, to 200 Deg.C, #18, 1 pair (for #14 horn/strobe circuit)1 Elec81C.L.F.077Union2007U829032
4.00026053 365 2200Pull boxes, sheet metal, type SC, raintight & weatherproof, 8" L x 6" W x 6" D, NEMA 3R1 Elec81Ea.077Union2007U840352
0.000(DTX - VISION 21 RADIO TRANSMITTER)Ea.
0.00027153 310 3850Coaxial cable, 50 ohm, RG A/U #58 cable1 Elec81C.L.F.077Union2007U829582
0.00027153 310 3540Coaxial connectors, BNC plug for, RG A/U #58 cable1 Elec420.19Ea.077Union2007U829452
0.00027411 910 1910T.V. SYSTEMS, antenna1 Elec24Ea.077Union2007U918412
0.00026281 620 0100Safety switches, general duty, 3 pole, fusible, 240 volt, 30 amp, NEMA 11 Elec3.22.5Ea.077Union2007U870262
0.00026051 990 1200Wire, copper, stranded, 600 volt, #12, type THWN-THHN, in raceway1 Elec110.727C.L.F.077Union2007U831442
0.00026052 680 3790Insulated ground wire, copper, stranded, 1/02 Elec6.62.424C.L.F.077Union2007U837512
Totals
ADDENDUM # 1, ADDED (2) SMOKE DUCT DETECTORS AND SHUTDOWN RELAY
2.00028314 650 5420Detection Systems, smoke detector, duct type, addressable, excl. wires & conduit1 Elec3.22.5Ea.077Union2007U911982
1.00028312 350 4050Detection Systems, fire alarm control panel, actuating device, excl. wires & conduit1 Elec81Ea.
0.50026052 320 1850Fire alarm cable, FEP teflon, 150 volt, to 200 Deg.C, #18, 1 pair (for #16 detection circuits)1 Elec81C.L.F.077Union2007U829032