W912BV18R0003-AM03.pdf

PDF 10 MB Posted

Attached to
Reception Complex Phase II at Fort Sill, OK Federal contract opportunity
Solicitation number
W912BV18R0003
Issued by
Department of the Army Corps of Engineers Engineering District Tulsa

About this file

Amendment 0003

View the file

Other files for this federal contract opportunity

Other files attached to Reception Complex Phase II at Fort Sill, OK, newest first.
File Type Posted
W912BV18R0003-AM02.pdf PDF
W912BV18R0003-AM01.pdf PDF
SOLICITATION_-_VOLUME-2-RSB_DESIGN_ANALYSIS.pdf PDF
SOLICITATION_-_VOLUME-1-RSB_DESIGN_ANALYSIS.pdf PDF
SOLICITATION_-_VOLUME-3-RSB_DESIGN_ANALYSIS.pdf PDF
VOLUME_III_-_BRAVO_&_CHARLIE_BATTERY.pdf PDF
VOLUME_II_-_ALPHA_BATTERY.pdf PDF
VOLUME_I_-_SITE,_CIVIL_&_ELECTRICAL.pdf PDF
VOLUME_III_-_BRAVO_&_CHARLIE_BATTERY.pdf PDF
VOLUME_II_-_ALPHA_BATTERY.pdf PDF
SOLICITATION_-_VOLUME-2-RSB_DESIGN_ANALYSIS.pdf PDF
VOLUME_I_-_SITE,_CIVIL_&_ELECTRICAL.pdf PDF
W912BV18R0003.pdf PDF
W912BV18R0003.pdf PDF
SOLICITATION_-_VOLUME-1-RSB_DESIGN_ANALYSIS.pdf PDF
Show all 15

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT

Except as provided herein, all terms and conditions of the document referenced in Item 9A or 10A, as heretofore changed, remains unchanged and in full force and effect.

15A. NAME AND TITLE OF SIGNER (Type or print)

30-105-04EXCEPTION TO SF 30

APPROVED BY OIRM 11-84

STANDARD FORM 30 (Rev. 10-83) Prescribed by GSA

FAR (48 CFR) 53.243

See summary of changes.

1. CONTRACT ID CODE PAGE OF PAGES

1 117

16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)

16C. DATE SIGNED

BY 07-Jan-2018

16B. UNITED STATES OF AMERICA15C. DATE SIGNED15B. CONTRACTOR/OFFEROR

(Signature of Contracting Officer)(Signature of person authorized to sign)

8. NAME AND ADDRESS OF CONTRACTOR (No., Street, County, State and Zip Code) X W912BV18R0003

X 9B. DATED (SEE ITEM 11)

30-Nov-2017

10B. DATED (SEE ITEM 13)

9A. AMENDMENT OF SOLICITATION NO.

11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS

X The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offer is extended, X is not extended.

Offer must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended by one of the following methods:

(a) By completing Items 8 and 15, and returning 1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted;

or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGMENT TO BE RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted, such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.

12. ACCOUNTING AND APPROPRIATION DATA (If required)

13. THIS ITEM APPLIES ONLY TO MODIFICATIONS OF CONTRACTS/ORDERS.

IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.

A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE

CONTRACT ORDER NO. IN ITEM 10A.

B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(B).

C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:

D. OTHER (Specify type of modification and authority)

E. IMPORTANT: Contractor is not, is required to sign this document and return copies to the issuing office.

14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)

10A. MOD. OF CONTRACT/ORDER NO.

2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO.(If applicable)

6. ISSUED BY

3. EFFECTIVE DATE

07-Jan-2018

CODE

CONTRACTING DIV

US ARMY CORPS OF ENGINEERS, TULSA DISTRICT

2488 E. 81ST STREET

TULSA OK 74137-4290

W912BV 7. ADMINISTERED BY (If other than item 6)

4. REQUISITION/PURCHASE REQ. NO.

CODE

See Item 6

FACILITY CODECODE

EMAIL:TEL:

AMENDMENT 0003

RECEPTION COMPLEX PHASE

II FORT SILL, OKLAHOMA

W912BV-18-R-0003

SUMMARY OF CHANGES

The solicitation documents are revised as follows:

The revised drawings/new sections/appendices listed below are hereby added to or revised and made a part of the solicitation. Revised or added/deleted information can be located in the specifications by searching for an asterisk and amendment number (e.g. *AM1).

Amended items: The following have been partially amended via this amendment.

1. DRAWINGS

a. Revised Drawings: The following is a list of revised drawings. A copy of the revised drawings accompanies this amendment.

G-002 INDEX OF DRAWINGS

C519A AMERICAN WATER WATER DETAILS VI

ALPHA DRAWINGS

1A-404 INTERIOR ELEVATIONS

1P-501 PLUMBING DETAILS

1P-901 DOMESTIC HOT, COLD, RECLAIMED AND GAS WATER PLAN AREA

A & D EXPLODED ISOMETRIC

1P-903 DOMESTIC HOT, COLD, RECLAIMED AND GAS WATER PLAN AREA

B & E EXPLODED ISOMETRIC

1EP-101 POWER PLAN 1ST FLOOR AREA A

1EP-102 POWER PLAN 1ST FLOOR - AREA B

1EP-103 POWER PLAN 1ST FLOOR - AREA C

1EP-104 POWER PLAN 1ST FLOOR - AREA D

1EP-105 POWER PLAN 1ST FLOOR - AREA E

1EP-106 POWER PLAN 2ND FLOOR - AREA A

1EP-107 POWER PLAN 2ND FLOOR - AREA B

1EP-108 POWER PLAN 2ND FLOOR - AREA C

1EP-109 POWER PLAN 2ND FLOOR - AREA D

1EP-110 POWER PLAN 2ND FLOOR - AREA E

1ET-101 COMMUNICATIONS PLAN 1ST FLOOR AREA A

1ET-102 COMMUNICATIONS PLAN 1ST FLOOR AREA B

1ET-103 COMMUNICATIONS PLAN 1ST FLOOR AREA C

1ET-104 COMMUNICATIONS PLAN 1ST FLOOR AREA D

1ET-105 COMMUNICATIONS PLAN 1ST FLOOR AREA E

1ET-106 COMMUNICATIONS PLAN 2ND FLOOR AREA A

1ET-107 COMMUNICATIONS PLAN 2ND FLOOR AREA B

1ET-108 COMMUNICATIONS PLAN 2ND FLOOR AREA C

1ET-109 COMMUNICATIONS PLAN 2ND FLOOR AREA D

1ET-110 COMMUNICATIONS PLAN 2ND FLOOR AREA E

1ET-603 DOOR ALARM RISER DIAGRAM

BRAVO/CHARLIE DRAWINGS

2MP-101 FIRST FLOOR HYDRONIC PLAN - A

2MP-102 FIRST FLOOR HYDRONIC PLAN - B

2MP-103 FIRST FLOOR HYDRONIC PLAN - C

2MP-104 FIRST FLOOR HYDRONIC PLAN - D

2P-501 PLUMBING DETAILS

2EP-101 POWER PLAN 1ST FLOOR AREA A

2EP-102 POWER PLAN 1ST FLOOR - AREA B

2EP-103 POWER PLAN 1ST FLOOR - AREA C

2EP-104 POWER PLAN 1ST FLOOR - AREA D

2EP-105 POWER PLAN 1ST FLOOR - AREA E

2EP-106 POWER PLAN 2ND FLOOR - AREA A

2EP-107 POWER PLAN 2ND FLOOR - AREA B

2EP-108 POWER PLAN 2ND FLOOR - AREA C

2EP-109 POWER PLAN 2ND FLOOR - AREA D

2ET-101 COMMUNICATIONS PLAN 1ST FLOOR AREA A

2ET-102 COMMUNICATIONS PLAN 1ST FLOOR AREA B

2ET-103 COMMUNICATIONS PLAN 1ST FLOOR AREA C

2ET-104 COMMUNICATIONS PLAN 1ST FLOOR AREA D

2ET-105 COMMUNICATIONS PLAN 1ST FLOOR AREA E

2ET-106 COMMUNICATIONS PLAN 2ND FLOOR AREA A

2ET-107 COMMUNICATIONS PLAN 2ND FLOOR AREA B

2ET-108 COMMUNICATIONS PLAN 2ND FLOOR AREA C

2ET-109 COMMUNICATIONS PLAN 2ND FLOOR AREA D

2ET-604 DOOR ALARM RISER DIAGRAM

2. SPECIFICATIONS

a. Revised Specifications: The following is a list of revised specifications. A copy of the revised drawings accompanies this amendment.

08 11 13 STEEL DOORS AND FRAMES

08 71 00 DOOR HARDWARE

08 81 00 GLAZING

09 30 10 CERAMIC, QUARRY, AND GLASS TILING

33 40 00 STORM DRAINAGE UTILITIES

b. Revised Specifications: The following is a list of deleted specifications.

00 73 46 05 56 53 08 11 69

WAGE RATE DETERMINATION

BLAST RESISTANT TEMPERED GLASS

WINDOW METAL STORM DOORS

W912BV18R0003

WAGE RATE DETERMINATION

General Decision Number: OK180043 01/05/2018 OK43

Superseded General Decision Number: OK20170043

State: Oklahoma

Construction Type: Building Building Construction -does not include residential construction consisting of single family homes and apartments up to and including 4 stories.

County: Comanche County in Oklahoma.

Note: Under Executive Order (EO) 13658, an hourly minimum wage of $10.35 for calendar year 2018 applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2015.

If this contract is covered by the EO, the contractor must pay all workers in any classification listed on this wage determination at least $10.35 per hour (or the applicable wage rate listed on this wage determination, if it is higher) for all hours spent performing on the contract in calendar year 2018. The EO minimum wage rate will be adjusted annually.

Please note that this EO applies to the above-mentioned types of contracts entered into by the federal government that are subject to the Davis-Bacon Act itself, but it does not apply to contracts subject only to the Davis-Bacon Related Acts, including those set forth at 29 CFR 5.1(a)(2)-(60). Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.

Modification Number Publication Date 0 01/05/2018

BROK0005-004 06/01/2016

Rates Fringes

BRICKLAYER.......................$ 23.34 9.01

ELEC1141-011 05/29/2017

Rates Fringes

ELECTRICIAN (Excludes Low Voltage Wiring)..................$ 31.80 17.25%+5.40

* ENGI0627-020 06/01/2017

Rates Fringes

POWER EQUIPMENT OPERATOR:

Group 1.....................$ 28.65 12.98 Group 2.....................$ 26.95 12.98 Group 3.....................$ 26.40 12.98 Group 4.....................$ 25.65 12.98 Group 8.....................$ 22.70 12.98 Group10.....................$ 21.70 12.98

POWER EQUIPMENT OPERATOR

GROUP 1: All Crane Type Equipment 200 ton and larger and including 400 ton capacity cranes. All Tower Cranes.

GROUP 2: All Crane Type Equipment 100 ton capacity and larger cranes, and less than 200 ton capacity.

GROUP 3: All Crane Type Equipment 50 ton capacity and larger cranes, and less than 100 ton capacity. Crane Equipment (as rated by mfg.) 3 cu. yd. and over Guy derrick Whirley Power Driven Hole Digger (with 30' and longer mast).

GROUP 4: CRANES with Boom Incl. Jib less than 100 ft and less than 3 cu. Yd.; Overhead Monorail Crane

GROUP 8: FORK-LIFT

GROUP 10:OILER; SEMI-TRAILER TRUCK DRIVER

IRON0048-014 06/01/2017

Rates Fringes

IRONWORKER (Ornamental and Structural)......................$ 24.00 14.81

PLUM0344-006 07/01/2017

Rates Fringes

PLUMBER (Excludes HVAC Pipe Installation)....................$ 31.73 14.90

PLUM0344-024 07/01/2017

Rates Fringes

PIPEFITTER (Including HVAC Pipe Installation)...............$ 31.73 14.90

ROOF0143-001 06/01/2017

Rates Fringes

ROOFER...........................$ 21.05 7.62

SHEE0124-010 07/01/2017

Rates Fringes

SHEET METAL WORKER (HVAC Duct Installation Only)...............$ 31.00 15.32

SUOK2012-023 07/30/2012

Rates Fringes

CARPENTER (Drywall Hanging Only)............................$ 15.50 2.80

CARPENTER, Excludes Drywall Hanging..........................$ 15.50 2.80

CEMENT MASON/CONCRETE FINISHER...$ 16.72 0.00

DRYWALL FINISHER/TAPER...........$ 13.80 0.00

ELECTRICIAN (Low Voltage Wiring)..........................$ 20.08 5.43

IRONWORKER, REINFORCING..........$ 17.11 0.00

LABORER: Common or General......$ 9.31 0.00

LABORER: Mason Tender - Brick...$ 12.00 0.00

LABORER: Mason Tender - Cement/Concrete..................$ 13.00 1.91

LABORER: Pipelayer..............$ 12.39 0.00

OPERATOR:

Backhoe/Excavator/Trackhoe.......$ 21.25 4.35

OPERATOR: Bulldozer.............$ 20.64 2.35

OPERATOR: Grader/Blade..........$ 14.28 1.70

OPERATOR: Loader (Front End)....$ 16.18 0.00

PAINTER: Brush, Roller and Spray, Excludes Drywall Finishing/Taping.................$ 12.91 0.00

SHEET METAL WORKER, Excludes HVAC Duct Installation...........$ 21.82 0.00

TRUCK DRIVER: Dump and Flatbed Truck....................$ 11.60 0.00

WELDERS - Receive rate prescribed for craft performing operation to which welding is incidental.

Note: Executive Order (EO) 13706, Establishing Paid Sick Leave for Federal Contractors applies to all contracts subject to the Davis-Bacon Act for which the contract is awarded (and any solicitation was issued) on or after January 1, 2017. If this contract is covered by the EO, the contractor must provide employees with 1 hour of paid sick leave for every 30 hours they work, up to 56 hours of paid sick leave each year.

Employees must be permitted to use paid sick leave for their own illness, injury or other health-related needs, including preventive care; to assist a family member (or person who is like family to the employee) who is ill, injured, or has other health-related needs, including preventive care; or for reasons resulting from, or to assist a family member (or person who is like family to the employee) who is a victim of, domestic violence, sexual assault, or stalking. Additional information on contractor requirements and worker protections under the EO is available at www.dol.gov/whd/govcontracts.

Unlisted classifications needed for work not included within the scope of the classifications listed may be added after award only as provided in the labor standards contract clauses (29CFR 5.5 (a) (1) (ii)).

The body of each wage determination lists the classification and wage rates that have been found to be prevailing for the cited type(s) of construction in the area covered by the wage determination. The classifications are listed in alphabetical order of "identifiers" that indicate whether the particular rate is a union rate (current union negotiated rate for local), a survey rate (weighted average rate) or a union average rate (weighted union average rate).

Union Rate Identifiers

A four letter classification abbreviation identifier enclosed in dotted lines beginning with characters other than "SU" or "UAVG" denotes that the union classification and rate were prevailing for that classification in the survey. Example:

PLUM0198-005 07/01/2014. PLUM is an abbreviation identifier of the union which prevailed in the survey for this classification, which in this example would be Plumbers. 0198 indicates the local union number or district council number where applicable, i.e., Plumbers Local 0198. The next number, 005 in the example, is an internal number used in processing the wage determination. 07/01/2014 is the effective date of the most current negotiated rate, which in this example is July 1, 2014.

Union prevailing wage rates are updated to reflect all rate changes in the collective bargaining agreement (CBA) governing this classification and rate.

Survey Rate Identifiers

Classifications listed under the "SU" identifier indicate that no one rate prevailed for this classification in the survey and the published rate is derived by computing a weighted average rate based on all the rates reported in the survey for that classification. As this weighted average rate includes all rates reported in the survey, it may include both union and non-union rates. Example: SULA2012-007 5/13/2014. SU indicates the rates are survey rates based on a weighted average calculation of rates and are not majority rates. LA indicates the State of Louisiana. 2012 is the year of survey on which these classifications and rates are based. The next number, 007 in the example, is an internal number used in producing the wage determination. 5/13/2014 indicates the survey completion date for the classifications and rates under that identifier.

Survey wage rates are not updated and remain in effect until a new survey is conducted.

Union Average Rate Identifiers

Classification(s) listed under the UAVG identifier indicate that no single majority rate prevailed for those classifications; however, 100% of the data reported for the classifications was union data. EXAMPLE: UAVG-OH-0010 08/29/2014. UAVG indicates that the rate is a weighted union average rate. OH indicates the state. The next number, 0010 in the example, is an internal number used in producing the wage determination. 08/29/2014 indicates the survey completion date for the classifications and rates under that identifier.

A UAVG rate will be updated once a year, usually in January of each year, to reflect a weighted average of the current negotiated/CBA rate of the union locals from which the rate is based.

WAGE DETERMINATION APPEALS PROCESS

1.) Has there been an initial decision in the matter? This can be:

* an existing published wage determination

* a survey underlying a wage determination

* a Wage and Hour Division letter setting forth a position on a wage determination matter

* a conformance (additional classification and rate) ruling

On survey related matters, initial contact, including requests for summaries of surveys, should be with the Wage and Hour Regional Office for the area in which the survey was conducted because those Regional Offices have responsibility for the Davis-Bacon survey program. If the response from this initial contact is not satisfactory, then the process described in 2.)

and 3.) should be followed.

With regard to any other matter not yet ripe for the formal process described here, initial contact should be with the Branch of Construction Wage Determinations. Write to:

Branch of Construction Wage Determinations Wage and Hour Division U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

2.) If the answer to the question in 1.) is yes, then an interested party (those affected by the action) can request review and reconsideration from the Wage and Hour Administrator (See 29 CFR Part 1.8 and 29 CFR Part 7). Write to:

Wage and Hour Administrator U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

The request should be accompanied by a full statement of the interested party's position and by any information (wage payment data, project description, area practice material, etc.) that the requestor considers relevant to the issue.

3.) If the decision of the Administrator is not favorable, an interested party may appeal directly to the Administrative Review Board (formerly the Wage Appeals Board). Write to:

Administrative Review Board U.S. Department of Labor 200 Constitution Avenue, N.W.

Washington, DC 20210

4.) All decisions by the Administrative Review Board are final.

END OF GENERAL DECISION

(End of Summary of Changes)

G-002

IN

D

E X

O F

D R

A W

IN

G S

A M

E N

D M

E N

T

P

C

IS

N E

R O

S

C A

M A

C H

O

P

C

IS

N E

R O

S

C A

M A

C H

O

G-002 INDEX OF DRAWINGS

TITLE/DESCRIPTION

DESIGNED BY: DENNIS MICHAEL KELLEY

NUMBER

SHEET

C-519A

TITLE/DESCRIPTION

NUMBER

SHEET

CIVIL

AMERICAN WATER WATER DETAILS VI

1A-404

TITLE/DESCRIPTION

NUMBER

SHEET

VOLUME II - ALPHA

VOLUME I - SITE, CIVIL & ELECTRICAL

ARCHITECTURAL

INTERIOR ELEVATIONS

PLUMBING

1P-903

1P-901

1P-501

DOMESTIC HOT, COLD, RECLAIMED AND GAS WATER PLAN AREA B & E EXPLODED ISOMETRIC

DOMESTIC HOT, COLD, RECLAIMED AND GAS WATER PLAN AREA A & D EXPLODED ISOMETRIC

PLUMBING DETAILS

ELECTRICAL

VOLUME III - BRAVO/CHARLIE

TELECOMMUNICATIONS

1EP110

1EP109

1EP108

1EP107

1EP106

1EP105

1EP104

1EP103

1EP102

1EP101

1ET603

1ET110

1ET109

1ET108

1ET107

1ET106

1ET105

1ET104

1ET103

1ET102

1ET101

POWER PLAN 2ND FLOOR - AREA E

POWER PLAN 2ND FLOOR - AREA D

POWER PLAN 2ND FLOOR - AREA C

POWER PLAN 2ND FLOOR - AREA B

POWER PLAN 2ND FLOOR - AREA A

POWER PLAN 1ST FLOOR - AREA E

POWER PLAN 1ST FLOOR - AREA D

POWER PLAN 1ST FLOOR - AREA C

POWER PLAN 1ST FLOOR - AREA B

POWER PLAN 1ST FLOOR - AREA A

DOOR ALARM RISER DIAGRAM

COMMUNICATIONS PLAN 2ND FLOOR - AREA E

COMMUNICATIONS PLAN 2ND FLOOR - AREA D

COMMUNICATIONS PLAN 2ND FLOOR - AREA C

COMMUNICATIONS PLAN 2ND FLOOR - AREA B

COMMUNICATIONS PLAN 2ND FLOOR - AREA A

COMMUNICATIONS PLAN 1ST FLOOR - AREA E

COMMUNICATIONS PLAN 1ST FLOOR - AREA D

COMMUNICATIONS PLAN 1ST FLOOR - AREA C

COMMUNICATIONS PLAN 1ST FLOOR - AREA B

COMMUNICATIONS PLAN 1ST FLOOR - AREA A

TITLE/DESCRIPTION

NUMBER

SHEET

PLUMBING

ELECTRICAL

TELECOMMUNICATIONS

PLUMBING DETAILS

MECHANICAL

2P-501

2MP104

2MP103

2MP102

2MP101

FIRST FLOOR HYDRONIC PLAN - D

FIRST FLOOR HYDRONIC PLAN - C

FIRST FLOOR HYDRONIC PLAN - B

FIRST FLOOR HYDRONIC PLAN - A

2EP109

2EP108

2EP107

2EP106

2EP104

2EP103

2EP102

2EP101

POWER PLAN 2ND FLOOR - AREA D

POWER PLAN 2ND FLOOR - AREA C

POWER PLAN 2ND FLOOR - AREA B

POWER PLAN 2ND FLOOR - AREA A

POWER PLAN 1ST FLOOR - AREA D

POWER PLAN 1ST FLOOR - AREA C

POWER PLAN 1ST FLOOR - AREA B

POWER PLAN 1ST FLOOR - AREA A

2ET604

2ET109

2ET108

2ET107

2ET106

2ET105

2ET104

2ET103

2ET102

2ET101

DOOR ALARM RISER DIAGRAM

COMMUNICATIONS PLAN 2ND FLOOR - AREA D

COMMUNICATIONS PLAN 2ND FLOOR - AREA C

COMMUNICATIONS PLAN 2ND FLOOR - AREA B

COMMUNICATIONS PLAN 2ND FLOOR - AREA A

COMMUNICATIONS PLAN 1ST FLOOR - AREA E

COMMUNICATIONS PLAN 1ST FLOOR - AREA D

COMMUNICATIONS PLAN 1ST FLOOR - AREA C

COMMUNICATIONS PLAN 1ST FLOOR - AREA B

COMMUNICATIONS PLAN 1ST FLOOR - AREA A

INDEX OF DRAWINGS

AMENDMENT 03

D w n b y

D e s ig n e d b y

R e v ie w e d b y

D a t e

S u b m it t e d b y

D e s c r ip t io n D a t e

A c t io n

S o l N o

C o n t r o

C o n t r e v number:

reference

Sheet

A

B

C

D

2 3 4 5

C O

R P

S

G

IN

E E

W

R T

H

T E

X A

U .S

A R

M Y

G

IN

E

IS

T R

IC

T

F il e n a m e

P lo t d a t e

P lo t s c a le

S y m b o l

US Army Corps of Engineers

Fort Worth District

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

IL

E S

R E

F E

R E

N C

E F

IL

E c a d d f il e n a m e t im e d a t e u s e r

T r a c k in g d a t e c a d d f il e n a m e

E N

G

IN

E E

R

IN

G

B

A N

C H

C O

N S

T R

U C

T

IO

IV

IS

IO

N

E N

G

IN

E E

R

IN

G

W

B V

R

R E

C E

P T

A T

R R

A C

K S

R

S B

F O

IL

L

O K

O C

T O

B

C-519A

D A

N G

J E

N N

IS

W A

T E

R D

E T

A

IL

S V I

A M

E R

IC

A N W

A T

D E

D S

H E c

S o li c it a ti o n N o

C O

N T

R N

V

NUMBER:

REFERENCE

SHEET

A

B

C

D

2 3 4 5

C O

R P

S O

F E

N G

IN

E E

R T W

O R

T H T

E X

U .S

A R

M Y E

N G

IN

E E

R D

IS

T R

IC

T

P L

O T D

A T

E

P L

O T S

C A

L E

C H

IE

F

C

IV

IL

S

E C

T

IO

N

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E

R E

F E

R E

N C

E F

IL

E S

R E

F E

R E

N C

E F

IL

E c a d d f il e n a m e ti m e d a te u s e r$

C A

D D F

IL

E N

A M

E

J

M E

S W

M C

K E

N Z

IE

P .E

D A

T E

US ARMY CORPS

OF ENGINEERS

W

B V -1

-R e s ig n e d b y

D ra w n b y

R e v ie w e d b y

S u b m it te d b y

D a te

C o n tr a c t

N o

F il e n a m e

S y m b o l

D e s c ri p ti o n

T ra c k in g N o

A c ti o n

D a te

FORT WORTH DISTRICT

US ARMY CORPS

OF ENGINEERS

TULSA DISTRICT

J

N U

A R

Y

C E

P T

A T

R R

A C

K S

(R

S B

F O

R T

S

IL

L

O K

C O

M P

L

X

P H

A S

E

II

J

M C

K E

N Z

IE

P .E

E N

G

IN

E E

R

IN

G B

R A

N C

H

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

01_FLOOR

0"

JAN.

C114

WALL TILE

MOP SINK

01_FLOOR

0"

TOILETS

A113

DRY AREA

A111

SHOWERS

A109

SOLID SURFACE SHOWER SURROUND WALL TILE WALL TILE

01_FLOOR

0"

DRY AREA

A111

SHOWERS

A109

TOILETS

A113

WALL TILE WALL TILE SOLID SURFACE SHOWER

SURROUND

01_FLOOR

0"

LAUNDRY

A116

WALL TILE

01_FLOOR

0"

LAUNDRY

A116

WALL TILE

01_FLOOR

0"

LAUNDRY

A116

WALL TILESTACKED DRYERS

01_FLOOR

0"

JAN.

A108

1/2" HIGH IMPACT GWB

1. LAVATORIES

(MEASURED FROM FLOOR TO RIM)

A. GENERAL 32"

B. ACCESSIBLE 34" MAX (29" MIN KNEESPACE)

2. URINALS

(MEASURED FROM FLOOR TO RIM)

A. GENERAL 24"

B. ACCESSIBLE 17"

3. TOILETS

(MEASURED FROM FLOOR TO TOP OF SEAT)

A. GENERAL 15"

B. ACCESSIBLE 17"

4. DRINKING FOUNTAINS

(MEASURED FROM FLOOR TO SPOUT OUTLET)

A. GENERAL 42"

B. ACCESSIBLE 36" MAX (27" MIN KNEESPACE)

5. ACCESSIBLE GRAB BARS

(MEASURED FROM FLOOR TO CENTERLINE OF BAR)

A. ACCESSIBLE 34"

6. HANDS FREE PAPER TOWEL DISPENSER

(MEASURED FROM FLOOR TO SENSOR)

A. GENERAL 48"

7. TOILET TISSUE DISPENSER

(MEASURED FROM FLOOR TO CENTERLINE OF ROLL)

A. GENERAL 20"

B. ACCESSIBLE 15"

8. HANDS FREE SOAP DISPENSER

(MEASURED FROM FLOOR TO CENTERLINE OF SENSOR)

A. GENERAL 38"

9. SANITARY NAPKIN DISPOSAL UNIT

(MEASURED FROM FLOOR TO TOP OF UNIT)

A. GENERAL 34"

10. MIRRORS

(MEASURED FROM FLOOR TO BOTTOM OF REFLECTING SURFACE)

A. GENERAL 40"

11. SHOWER HEADS

(MEASURED FROM FLOOR TO HEAD)

A. ACCESSIBLE 72" TO SHOWER HEAD

48" TO TOP OF CONTROLS

12. SHOWER CURTAINS AND RODS

(MEASURED FROM FLOOR TO BOTTOM OF CURTAIN)

A. GENERAL 1"

FIXTURE MOUNTING HEIGHTS

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D e si gn ed b y:

S ub m itt e d b y:

F ile

N am e

D a te

C o n tr a ct

N o

S ol ic ita tio n

N o

U .S

. A R

M Y

E N

G

IN

E E

R D

IS

T

R

IC

T

C O

R P

S O

F E

N G

IN

E

E R

S F

O R

T W

O R

T H

, T E

X A

S

R e vi ew ed b y:

US Army Corps of Engineers ®

D

C

B

A

P lo t S ca le

P lo t D a te

R e v:

S ym bo l

D e sc rip tio n

T ra ck in g N o

A ct io n

D a te

E N

G

IN

E E

R

IN

G

C O

N S

T R

U C

T

IO

N D

IV

IS

IO

N

E N

G

IN

E E

R

IN

G B

R A

N C

H

US Army Corps of Engineers ®

Tulsa District

A s in d ic at e d c R

E C

E P

T

IO

N S

T A

T

IO

N B

A R

R A

C K

S (R

S B

F

O R

T S

IL

L

, O K

A L

P H

A B

A

TT

E R

Y C

O M

P L

E X

P H

A S

E

II

O C

T O

B E

R

W

2B

V -1

-R

Fort Worth District

A

E

LL

IS

II

I

A

E

LL

IS

II

I

JE

N

N

IF

E R

A . D

E W

IT

T

, R .A

C

H

IE

F , A

R C

H

IT

E C

T U

R E

S E

C T

IO

N

1A-404

IN

T

E R

IO

R

E L

E V

A T

IO

N

S B

T

IN

D

E

LL

R

.A

/2 0/

1/4" = 1'-0"5

JANITOR CLOSET - 1

1/4" = 1'-0"1

SHOWERS/TOILETS

1/4" = 1'-0"3

SINK/SHOWER - 1

1/4" = 1'-0"2

WASHER - 1

1/4" = 1'-0"4

WASHER - 2

1/4" = 1'-0"7

WASHER - 3

1/4" = 1'-0"6

JANITOR CLOSET - 2

02 4 8134 02 4 8134

02 4 8134

02 4 8134

02 4 8134 02 4 8134 02 4 8134 c c c c c c c c c c c cc

R E

V

IS

E D

W A

LL

F

IN

IS

H E

S c

A

M

JA

N

NOT TO SCALE

FLOOR CLEANOUT

CLEANOUT COVER CSK SCREW

CLEANOUT PLUG

FINISHED FLOOR

CAULKING FERRULE

CONCRETE SURFACE

OR FLOOR COVERING

AS REQUIRED

FLOW

NOT TO SCALE

ISOLATION VALVE (TYP.)

CHECK VALVES

TEST

COCK

REDUCED PRESSURE

RELIEF PORT

ROUTE TO DRAIN

REDUCE PRESSURE BACKFLOW PREVENTER DETAIL

AIR GAP TYPE

DRAIN FUNNEL

TEST COCK

(TYP.)

12" MIN.

CLEARANCE

12" MIN.

CLEARANCE

SPOUT WITH HOSE

END AND PAILHOOK

SPOUT BRACE

SERVICE FAUCET

w/VACUUM BREAKER

METAL EDGE

P-TRAP

DRAIN

H C

ADJUSTABLE

STRAINER

CAST IRON

P-TRAP

PRE-FAB

SHOWER

FLOOR

CLAMPING RING

FLOOR

SLAB

DRAIN

BODY

WASTE LINE

WASTE LINE

LENGTH TO SUIT

FLOW

2"x1/4" BAR CLAMP

SLIP JOINT

STAINLESS STEEL

RAIN CAP

SEE ARCH.

DRAWINGS

…" BOLT (TYP)

SINGLE WALL STEEL

VENT PIPE

METAL DECK

INSULATION

OPEN

WEB

JOIST

TYPICAL

ATTACHMENT

TO FRAME

1/8 1/8

2" MIN. CLEARANCE

TO COMBUSTIBLE

MATERIAL

SPARK ARRESTOR

STORM COLLAR

w/DRAW BAND

24 GALV. STEEL

SLEEVE

SEALANT No.2 OR No.4 4" x 3" x 1/4"

ANGLE FRAME

DOUBLE WALL TYPE

430 STAINLESS

STEEL VENT PIPE

(TERMINATE 2 FT.

BELOW ROOF)

3' -0

M

IN

FIRESTOPPING SEE

SPECIFICATIONS

FOR FIRE RATING

SEE SPECIFICATIONS

FOR REQUIREMENT

ESCUTCHEON; (ON

FINISHED, VISIBLE

SURFACES ONLY)

BACKUP

MATERIAL;

TYPICAL

INSULATED OR

UNINSULATED

PIPE

PIPE

SLEEVE

3/8"

MINERAL WOOL FULL

THICKNESS OF WALL

ESCUTCHEON (ON

FINISHED, VISIBLE

SURFACES ONLY)

INSULATED OR

UNINSULATED PIPE

NOT TO SCALE

MOP BASIN DETAIL

NOT TO SCALE

SHOWER DRAIN DETAIL

NOT TO SCALE

WALL CLEANOUT

C.I. CLEANOUT TEE

MAY EXTEND AS

WASTE OR VENT

COUNTERSUNK

SCREW

POLISHED S.S.

ACCESS COVER

COMBINATION 1/8"

BEND AND "Y"

CLEANOUT PLUG

FOR WALL

CONSTRUCTION SEE

ARCH. DRAWINGS

NOT TO SCALE

FLUE DETAIL

3" STAND PIPE

2" VENT

HOSE BIBB

SUPPLY

FITTINGS

WASHING MACHINE

ROUGH-IN UNIT

3" DRAIN TO

SANITARY

SEWER

12" x 12"

ACCESS PANEL

FINISHED

FLOOR 3"

P-TRAP

HOT COLD

AP

PR

O X.

6"

A

FF

M

IN

. 1 8"

NOT TO SCALE

WASHING MACHINE HOOK UP DETAIL

LINT INTERCEPTOR

NOT TO SCALE

LINT SCREEN

OUTLET

INLET

SECURED GASKETED

COVER

SECONDARY

LINT SCREEN

NOT TO SCALE

PIPE THRU FLOOR PIPE THRU STUD WALL

NOT TO SCALE

SLEEVE WITH 26 GA

SHEET METAL

NOT TO SCALE

HANGER

CLEVIS

ADJUSTABLE CLEVIS HANGER

CARRIER PIPE

CLEVIS BOLT

SUPPORT ROD

SUSPENDED FROM

STRUCTURE

B D E

A F C

D. ADAPTOR - STEEL TO PLASTIC

B. WELD - ELECTRIC INERT GAS

F. RETAINER TUBE (STEEL)

E. O-RING

NOT TO SCALE

ANODELESS RISER

F

B A

E

D C

C. POLYETHYLENE GAS PIPE OR

TUBING

A. STEEL PIPE-SCHEDULE 40-A53

TOP

ADAPTOR

BOTTOM

ADAPTOR

NOT TO SCALE

NUT

STEEL WASHER FLANGES

PIPE

FLANGE BOLT

STEEL WASHER

„" THICK

INSULATING

GASKET SET

SIMILAR

INSULATING BOLT SLEEVE

ˆ" MIN. WALL THICKNESS

ISOLATION FLANGE

NOTE:

CONTRACTOR SHALL COMPLY WITH THE ISOLATION

FLANGE MANUFACTURER'S RECOMMENDATIONS FOR

BOLT TORQUES AND BOLTING PATTERN. CONTRACTOR

SHALL ALSO RECHECK BOLT TORQUES 72 HOURS AFTER

SYSTEM STARTUP.

NOTE:

REFER TO CIVIL SHEETS FOR LOCATION AND INVERT ELEVATIONS.

TRAP SEAL

DEVICE

THE ENGLISH METERING

COMPANY, INC.

TULSA, OKLAHOMA

NOT TO SCALE

PLUG VALVE(TYP.)

UNION(TYP.)

DISC-TYPE

WATER METER

COVER WITH

HINGED LID

FINISHED

GRADE

WATER METER INSTALLATION DETAIL

2'-0" X 2'-0" BLOCKOUTA

B

C

G, F H I

A. FLOOR LINE

B. FLASHING CLAMP

C. DRAIN BODY

D. TRAP SEAL REFER TO

PLUMBING SPECIFICATIONS

E. P-TRAP

F. 1/2" RAISED FLANGE,

TRAFFIC GRATE

G. FULL GRATE UNLESS

OTHERWISE

SCHEDULED

OR SPECIFIED

H. DOME STRAINER

I. FLOOR SINK OUTLET

(2" MINIMUM)

NOT TO SCALE

FLOOR SINK

M

NOT TO SCALE

GAS METER DETAIL

REFER TO

OKLAHOMA

ONE GAS

TO BE

PROVIDED BY

SITE UTILITY

TO BE

PROVIDED BY

BUILDING

CONTRACTOR

PULSE METER

TO DDC

D

E

AIRGAP 3 X

PIPE DIAMETER

TRAP SEAL

DEVICE

TO BUILDING

FROM SITE

1/8" WYE COMBO

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T, C O

R

PS

O F

EN

G

IN

EE

R S

FO

R

T W

O R

TH

, T

EX

A

S

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ®

Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/2

'-0

1/ 5/

:5

9:

A M

L R

EC

E P

TI

O

N

ST

AT

IO

N B A

RR

A C

KS

(R

SB

FO

R T

S

IL

L , O

K

AL

PH

A

BA

T T

ER

Y

C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

S.

SL

AU

G

H

TE

R

K.

W

IL

LI

AM

S, P .E

G

IL

BE

R

T J.

V

AL

LA

, P

.E

C H

IE

F, M

EC

H

AN

IC

AL

S

EC

TI

O

N

1P-501

P L U

M B

IN

G

D

ET

A

IL

S K.

W

IL

LI

AM

S, P

.E

1 2 3 4 5

6 7 8 9

11 12 13 cc c c U

PD

AT

ED

S

H O

W

ER

D R

AI

N

D

ET

AI

L

AM

JA

N

P-1

(TYP-6)

P-1

(TYP-6)

P-1

(TYP-6)

P-1

(TYP-6)

P-8

P-8

3/4" DCW

1 1/2" DHW

1 1/2" DHW

1 1/4" DCW

1 1/4" DCW

3/4" DCW

3" DCW

3" DHW

3/4" DHWR

4" DHW

3" DCW

3" NPW

1 1/4" DCW

3/4" DHW

3/4" DCW

P-8

3/4" DHW

3/4" DCW

1 1/4" DCW

1 1/2" DHW

3/4" DHW

3/4" DCW

1 1/2" DHW

1 1/4" DCW

3/4" DCW

P-8

P-13

(TYP-8)

P-13

(TYP-8)

1 1/4" DCW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/4" DCW

3" DCW

3/4" DHWR

3" NPW

3" DHW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/2" DHW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

FD

(TYP)

GENERAL NOTES

1. CONNECTIONS TO EACH FIXTURE NOT SHOWN FOR CLARITY.

2. SHOWERS SHALL BE BACK TO BACK TO SHARE PIPING.

3. SHOWER HEADS SHALL BE LOCATED 90 DEGREES FROM

OPENING SUCH THAT THE DISCHARGE DOES NOT LEAVE

THE SHOWER PAN.

4. SHOWER VALVES SHALL BE ADJUSTED TO LIMIT DISCHARGE

TEMPERATURE TO 120 DEGREES FAHRENHEIT.

2" DHW

2" DHW

2" DCW

2" DCW

P-5

(TYP-8)

P-13

(TYP-8)

P-13

(TYP-8)

P-8

P-8

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/4" DCW

1 1/2" DHW

3/4" DHW

3/4" DCW

3/4" DCW

1 1/4" DCW

1 1/4" DCW

1 1/2" DHW

1 1/2" DHW

3/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

3/4" DCW

P-5

(TYP-8)

P-13

(TYP-8)

V

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

3/4" DCW

3/4" DCW

2" DHW

2" DCW

2" DCW

2" DHW

2" DCW

2" DHW

P-10

(TYP)

3" DHW

2" DCW

2" DHW

2" DCW

3/4" DCW

3/4" DHW

3/4" DCW

3/4" DHW

3/4" DHW

3/4" DCW

3/4" DHW

3/4" DCW

1 1/2" NG

1 1/2" NG

2" NG

1 1/2" NG

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T, C O

R

PS

O F

EN

G

IN

EE

R S

FO

R

T W

O R

TH

, T

EX

A

S

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ®

Tulsa District

US Army Corps of Engineers ®

Fort Worth District

1/ 5/

:0

0:

A M

L R

EC

E P

TI

O

N

ST

AT

IO

N B A

RR

A C

KS

(R

SB

FO

R T

S

IL

L , O

K

AL

PH

A

BA

T T

ER

Y

C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

S.

SL

AU

G

H

TE

R

S.

S

LA

U

G H

TE

R

G

IL

BE

R

T J.

V

AL

LA

, P

.E

C H

IE

F, M

EC

H

AN

IC

AL

S

EC

TI

O

N

1P-901

D O

M

ES

TI

C

H O

T , C

O L D

, R E C

LA

IM

ED

A

ND

G

AS

W

AT

E R

P L A

N

AR

EA

A

D

EX

PL

O D E

D

IS

O M

ET

R I

C

K.

W

IL

LI

AM

S, P .E

1 DOMESTIC HOT, COLD, NON-POTABLE WATER AREA A & D EXPLODED ISOMETRIC

1 ISOLATION VALVES FOR DOMESTIC HOT AND COLD VALVES.

2 DCW LINE FOR ATTIC HOSE BIB.

3 PROVIDE WALL ACCESS PANEL FOR ISOLATION VALVE.

4 PROVIDE CEILING ACCESS PANEL TO ACCESS ISOLATION

VALVES.

5 TOILETS WILL BE SUPPLIED BY NPW MAIN TO BOTH FIRST

AND SECOND FLOOR. PIPING TO EACH TOILET NOT SHOWN

FOR CLARITY.

6 EACH WASHER UNIT SHALL HAVE WASHER BOX BEHIND THE

UNIT, WALL MOUNTED. PIPING TO EACH WASHER BOX NOT

SHOWN FOR CLARITY.

7 PROVIDE LINE SIZED ISOLATION VALVES AND WALL ACCESS

PANEL.

KEYED NOTES

c c c c c c c c c c c c

AD

D

K

EY

N O

TE

, R

ES

IZ

ED

A N

D

LA

BE

LE

D P

IP

ES

c

AM

JA

N

P-1

(TYP-6)

P-1

(TYP-6)

3" DHW

3" DCW

3/4" DCW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

4" DHW

3" NPW

3" DCW

3/4" DHWR

3/4" DHW

3/4" DCW

3/4" DCW

3/4" DHW

3/4" DCW

1 1/4" DCW

1 1/2" DHW

3/4" DHW

3/4" DHW

3/4" DCW

3/4" DCW

3/4" DHWR

P-13

(TYP-8)

P-13

(TYP-8)

P-8

P-8

P-8

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

3" NPW

FD

(TYP)

GENERAL NOTES

1. CONNECTIONS TO EACH FIXTURE NOT SHOWN FOR CLARITY.

2. SHOWERS SHALL BE BACK TO BACK TO SHARE PIPING.

3. SHOWER HEADS SHALL BE LOCATED 90 DEGREES FROM

OPENING SUCH THAT THE DISCHARGE DOES NOT LEAVE

THE SHOWER PAN.

4. SHOWER VALVES SHALL BE ADJUSTED TO LIMIT DISCHARGE

TEMPERATURE TO 120 DEGREES FAHRENHEIT.

2" DCW

2" DCW

2" DHW

2" DHW

P-13

TYPICAL

1 1/2" DHW

1 1/4" DCW

1 1/4" DCW

1 1/2" DHW

P-5

(TYP-8) 1 1/2" DHW

3/4" DCW

1 1/2" DHW

1 1/4" DCW

P-5

TYPICAL

1 1/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/2" DHW

P-13

(TYP-8)

P-13

(TYP-8)

P-5

(TYP-8)

P-5

(TYP-8)

3/4" DCW

1 1/2" DHW

1 1/4" DCW

1 1/4" DCW

1 1/2" DHW

2" DCW

2" DHW

3" DCW4" DHW

3/4" DCW

2" DCW

2" DHW

3/4" DCW

3/4" DCW

3/4" DHW3/4" DHW

3/4" DCW

P-10

(TYP)

1 1/2" NG1 1/2" NG

1 1/2" NG

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T, C O

R

PS

O F

EN

G

IN

EE

R S

FO

R

T W

O R

TH

, T

EX

A

S

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ®

Tulsa District

US Army Corps of Engineers ®

Fort Worth District

1/ 5/

:0

0:

A M

L R

EC

E P

TI

O

N

ST

AT

IO

N B A

RR

A C

KS

(R

SB

FO

R T

S

IL

L , O

K

AL

PH

A

BA

T T

ER

Y

C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

S.

SL

AU

G

H

TE

R

S.

S

LA

U

G H

TE

R

G

IL

BE

R

T J.

V

AL

LA

, P

.E

C H

EI

F, M

EC

H

AN

IC

AL

S

EC

TI

O

N

1P-903

D O

M

ES

TI

C

H O

T , C

O L D

, R E C

LA

IM

ED

A

N D

G A

S W

A

TE

R P

L A N

A R

EA

B

E

EX

PL

O D

ED

IS

O M

ET

R I

C

K.

W

IL

LI

AM

S, P .E

1 DOMESTIC HOT, COLD, NON-POTABLE WATER AREA B & E EXPLODED ISOMETRIC

1 ISOLATION VALVES FOR DOMESTIC HOT AND COLD VALVES.

2 DCW LINE FOR ATTIC HOSE BIB.

3 PROVIDE WALL ACCESS PANEL FOR ISOLATION VALVE.

4 PROVIDE CEILING ACCESS PANEL TO ACCESS ISOLATION

VALVES.

5 TOILETS WILL BE SUPPLIED BY NPW MAIN TO BOTH FIRST AND

SECOND FLOOR. PIPING TO EACH TOILET NOT SHOWN FOR

CLARITY.

6 EACH WASHER UNIT SHALL HAVE WASHER BOX BEHIND THE

UNIT, WALL MOUNTED. PIPING TO EACH WASHER BOX NOT

SHOWN FOR CLARITY.

7 PROVIDE LINE SIZED ISOLATION VALVES AND WALL ACCESS

PANEL.

KEYED NOTES

NTS

7c c c c c c c c c c c c c

C

AM

JA

N cc c

AD

D

K

EY

N O

TE

, R

ES

IZ

ED

A N

D

LA

BE

LE

D P

IP

ES

W W W W W W W W WW W W W W W W W W WW

P

G F

WP

GF

WP

GF

W P

G F

W P

G F

GF GF GF GF GF

G

FG

F

GF GF GF GF GF

G F G F

G F

G F

GFGF J

J

JJ J J

J

A101

VEST.

A107

JAN.

A104

LUGGAGE

A105

LUGGAGE

A115

LAUNDRY

A108

JAN.

A114

TOILETS

A113

TOILETS

A109

SHOWERS

A112

DRY AREA

A110

SHOWERS

A116

LAUNDRY

A111

DRY AREA

A117

STAIR

A106

SLEEPING BAY

A102

CORRIDOR

A118

ELEC.

A103

SLEEPING BAY

A1L3-4

GF

A1L3-11

GF

A1L4-7

GF

A1L3-11

GF

A1L3-13

GF

A1L3-13

GF

A1L4-7

GF

A1L4-10

GF

A1L4-10

GF

A1L3-11

GF

A1L3-11

A1L5A1L6

TA1B

A1L3

A1 L3

-4

A1L3-4

A1 L3

-4

A1L1-16

A1L4-9

A1L4-9

A1L4-9

A1L4-9

A1L4-9

A1L3-8

A1L3-6

A1L3-6

A1L3-6

A1L3-6

A1L3-6

A1L4-11

A1L4-11

A1L4-11

A1L4-11A1L3-10

A1L3-10

A1L3-10

A1L3-10

A1L3-10A1L3-10 A1L4-9 A1L4-9

A1L3-8 A1L3-8 A1L4-8A1L4-8 A1L4-8

A1L4-8 A1L4-8 A1L3-8 A1L3-8 A1L4-8

A1 L3

-4

GF

A1L1-24

GF

A1L1-28

1EP401

1EP403

48"

AFF48" AFF

A1L4

A1LLA

A1L3-36

A1L4-17

A1L4-17

A1L4-17 A1L4-17

A1L4-17

A1L4-17

A1L4-17

A1L4-17

A1H1-7,9,11

T

VAV-SA-A1-02

VAV-OA-A1-01

VAV-SA-A1-01

VAV-OA-A1-03 VAV-OA-B1-03

VAV-SA-A1-03

VAV-SA-A1-04

VAV-OA-A1-02

FCU-A117

DSS-A218

DSS-A218

A1L4-19,21

A2L2-16,18

R RA1L4-9A1L3-6

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

A1L1-37

A1L3-9

A1L4-8 A1L4-8

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE ELECTRIFIED PANIC DEVICE A1L3-8 A1L3-8

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

A1L3-4

GENERAL NOTES:

1. PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH FOR VAV BOX.

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U.

S.

A

RM

Y

EN

G

IN

EE

R

DI

ST

RI

CT

CO

RP

S

O F

EN

G

IN

EE

RS

FO

RT

W

O

RT

H, T

EX

AS

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ® Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/8

'-0

1/ 5/

:2

5:

P M

L

RE

CE

PT

IO

N

ST

AT

IO

N

B A

RR

A C

KS

(R

SB

FO

R T S

IL

L , O K

AL

PH

A

BA

T T

ER

Y C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

T.

A

VE

R

Y, P

.E

T.

A

VE

R

Y, P

.E

D

AR

EN

A

. B R

O W

N C

H

IE

F, E

LE

C

TR

IC

AL

S

EC

TI

O N

1EP101

PO

W

ER

P

LA

N

ST

F L O

O R

- A

RE

A A

D . B

R O

W N

1/8" = 1'-0"1 POWER PLAN 1ST FLOOR - AREA A

D

E

KEY PLAN

C A

B

04 8 16268

PLAN

NORTH

KEYED NOTES

# NOTES

1 PROVIDE 30A, 240V, 2P, NEMA 3R SAFETY SWITCH.

2 PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH.

3 PROVIDE 3 #12 & 1 #12 GND IN 1/2" CONDUIT. PROVIDE 30A,

600V, 3P, NEMA 1 SAFETY SWITCH.

c ad d po w er to d oo rs am

Ja n ccc

W W W W W W W W WWW W W W W W W W WWGF GF GF GF GF

F

G F

GF GF GF GF GF

G F

G F

W P

G F

W P

G F

WP

GF

WP

GF

W P

G F

TV

GFGF

F F

J

J

J

J

J J J

J

J

C116

STORAGE

B101

STAIR

A101

VEST.

B104

LUGGAGE

B103

LUGGAGE

B106

JAN.

B114

LAUNDRY

B107

JAN.

B112

TOILETS

B108

SHOWERS

B110

DRY AREA

B109

SHOWERS

B111

DRY AREA

B113

TOILETS

B115

LAUNDRY

B116

VEST.

B118

CLOSET

B117

D.I. OFF.

A102

CORRIDOR

B119

TLT.

GF

A1L4-2

GF

A1L4-2

GF

A1L4-4

GF

A1L4-4

GF

A1L4-6

GF

A1L4-6

GF

A1L4-3

GF

A1L4-3

GF

A1L4-5

GF

A1L4-5

GF

A1L4-15

B102

SLEEPING BAY

B105

SLEEPING BAY

A1L8A1L7

TA1B

A1L3-9

A1L3-9

A1 L3

-3

A1 L3

-3

A1L3-3 A1L3-3

A1 L3

-3

A1L4-1 A1L4-1 A1L3-15

A1L3-15

A1L3-15

A1L3-15

A1L3-15

A1L4-1

A1L4-1

A1L4-1

A1L4-1

A1L3-17 A1L3-17A1L3-17A1L3-12 A1L3-12A1L3-12

A1L3-7 A1L3-7 A1L3-2

A1L3-9 A1L3-2

A1L3-9

A1L3-7

A1L3-7

A1L3-2

A1L3-2

A1L3-2

A1L3-17A1L3-17A1L3-12A1L3-12 A1L3-17

A1L4-12 A1L4-13

A1L4-13

A1L4-13A1L4-12

A1L4-12

A1L4-12

48" AFF48" AFF

A1L4-14

A1L4-12

A1L4-13

A1L3-34

A1L4-17

A1L4-17

A1L4-17 A1L4-17 A1L4-17 A1L4-17

A1L4-17

A1L4-17 A1L4-17

A1L4-17

A1L4-17

T

VAV-OA-A1-03 VAV-OA-B1-03

VAV-SA-B1-01

VAV-SA-B1-02

VAV-SA-B1-03

VAV-SA-B1-04

VAV-SA-B1-07

VAV-OA-B1-01

VAV-SA-B1-05

VAV-OA-B1-02

VAV-SA-B1-06

FCU-B101

1EP401

A1L3-2 A1L4-1

48" AFF

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

A1L3-14 A1L3-14

L

L L

L

A1L3-9

A1L3-9

A1L3-9

A1L3-12 A1L3-12

ELECTRIFIED PANIC DEVICE

ELECTRIFIED

PANIC DEVICE

ELECTRIFIED PANIC DEVICE ELECTRIFIED PANIC DEVICE ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

A1L3-17 A1L3-17

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

A1L3-15

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

A1L3-9

GENERAL NOTES:

1. PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH FOR VAV BOX.

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U.

S.

A

RM

Y

EN

G

IN

EE

R

DI

ST

RI

CT

CO

RP

S

O F

EN

G

IN

EE

RS

FO

RT

W

O

RT

H, T

EX

AS

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ® Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/8

'-0

1/ 5/

:2

5:

P M

L

RE

CE

PT

IO

N

ST

AT

IO

N

B A

RR

A C

KS

(R

SB

FO

R T S

IL

L , O K

AL

PH

A

BA

T T

ER

Y C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

T.

A

VE

R

Y, P

.E

T.

A

VE

R

Y, P

.E

D

AR

EN

A

. B R

O W

N C

H

IE

F, E

LE

C

TR

IC

AL

S

EC

TI

O N

1EP102

PO

W

ER

P

LA

N

ST

F L O

O R

- A

RE

A B

D . B

R O

W N

1/8" = 1'-0"1 POWER PLAN 1ST FLOOR - AREA B

D

E

KEY PLAN

C A

B

04 8 16268

PLAN

NORTH

KEYED NOTES

# NOTES

1 PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH.

c ad d po w er to d oo rs am

Ja n c c

SB SB SB

WP

GF

WP

GF

W P

G F

G F

WP

GF

WP

GF

WP

GF

G F

G F

GF

G F

G F

G F

GF

GF

F F C

G F

TV

TV

TV

TV

TV

TV

J

J

J

G F

J

J J

C117 W

C112

WOMEN

C113

MEN

C115

TELECOM

C111

BREAK

C105 A / V

C106

CO

C110

ANTE

C114

JAN.

C122

FIRE PUMP

C104

CONFERENCE

C118

ISSUING

C120

LINEN STOR.

C126

ELEC.

C123

RECYCLE

C124

RECEIVING

C103

RECEPTION

C108

1ST SGT.

C101

VEST.

C109

COPY/WORK

C121

BOILER / MECH

C125

OFFICE

C127

BOILER / MECH

C116

STORAGE

C107

XO

C102

ENTRY ATRIUM

E117

D.I. OFF.

D119

ELEC.

E119

TLT.

B119

TLT.

T

GF

A1L1-29

GF

A1L1-29

GF

A1L1-20

GF

A1L1-20

GF

A1L1-20

GF

A1L1-18

GF

A1L1-18

GF

A1L1-18

GF

A1L1-29

GF

A1L1-29

GF

A1L1-28

GF

A1L1-28

GF

A1L1-30

GF

A1L1-30

A1LLC

A1L1 A1H1

TA1A

TA1B

A1L3

A1LT

TA1C

A1L9

A1L1-12

A1L1-12

A1 L9

-2

A1L1-16

A1L1-16 A1L1-16

A1L1-16

A1L4-13

A1L10-6

A1L10-6

A1L10-6

A1L2-7 A1L2-7 A1L2-6 A1L2-6

A1L1-35

A1L1-25

A1L1-25 A1L1-25

A1L1-26

A1L1-25

A1L2-7

A1L2-7

A1 L2

-7

A1L2-7 A1L2-6

A1L2-6

A1L2-6

A1L2-6

A1L1-26

A1L1-26

A1L1-26

A1L1-35A1L1-35

A1L1-35 A1L1-35

A1L1-35

A1 L1

-2 4A1

L1 -2

GF

A1L1-24

GF

A1L1-24

GF

A1L1-28

A1L1-28

A1 L1

-2

G F

A1 L1

-2

A1 L1

-3

GF

A1L1-31

A1 L1

-3

A1L1-30

G F

A1 L1

-3

G F

A1 L1

-3

A1L1-31

A1L1-33 A1L1-33

A1L1-33 A1L1-33

A1L1-14

A1L1-33 A1L1-33

A1L1-14 A1L1-14

A1L1-17

A1L1-17

A1L1-13

A1L1-13

A1L1-13 A1L1-13A1L1-13 A1L1-13

A1L1-17

A1L1-17 A1L1-17

A1L1-27

A1L1-27

A1L1-27 A1L1-27

A1L1-27

A1L1-22

A1L1-22 A1L1-22

A1L1-22

A1L1-22

A1L1-34

A1L1-34

A1L1-34

A1L1-34

A1L1-34

A1L1-34

A1L2-5 A1L2-5A1L2-5

A1L2-5 A1L2-5

A1L1-32

A1L1-32

A1L1-23

A1L1-32 A1L1-32

A1L1-15 A1L1-14

A1L1-14

A1L2-5

A1L1-27

A1L1-14

A1 L1

-2

1EP403

1EP403

1EP403

A1LT-4

A1LT-3,5

A1L1-32

A1L4

A1LLA A1LLD

A1L10 A1H1-2,4,6

A1H1-19,21,23

A1H1-13,15,17 A1H1-7,9,11

A1H1-8,10,12

A1H1-14,16,18

A1L2-1

A1L2-2

A1L2-3

A1L2-9

VAV-SA-C1-03

A1L2-4

A1L2-4

A1L2-4

A1L2-4

A1L2-4

A1L2-4A1L2-4 A1L2-4

A1L2-4

A1L2-4 A1L2-4

A1L2-4

A1L2-4

A1L2-4

A1L2-4

A1L2-4

A1L2-4 A1L2-4

A1L1-23 A1L1-23

A1L1-23

A1L2

A1L1-10

POWER FOR FIRE ALARM

T T

VAV-OA-C1-04

VAV-SA-C1-04

AHU-2

VAV-OA-C1-03 VAV-SA-C1-05

VAV-SA-C1-06

VAV-SA-C1-09

VAV-SA-C1-10

VAV-SA-C1-12

VAV-SA-C1-08

VAV-SA-C1-07

VAV-OA-C1-05

VAV-SA-C1-11

VAV-OA-C1-06

VAV-SA-C1-01

DOAU-2

VAV-OA-C1-01

VAV-OA-C1-02

VAV-SA-C1-02

B-2

B-1

CP-1 CP-2

A1L2-8

A1L2-13

SWITCHBOARD AMDP

A1L1-21 A1L1-19

A1L1-36

A1L2-10

A1L2-12

DSS-D119

A1L10-8,10

DSS-C125

DSS-C126

A1L2-14,16

UH-C122

A1L2-18

A1L2-20,22

A1L2-20,22

DSS-C125

1EP403

A1LT-7,9

DSS-C115

R

R R

R

R

R R

AMDP-8

R 1

CH-1

HWP-1 HWP-2

ET-1

A1 L2

-1

FCU-C121

CWP-1

CWP-2

WH-1

FCU-C127

A1 H

1-

,2 7, A1 H

1-

,2 2, A1L2-17,19,21

BP-2

BP-1

A1L2-24,26,28

2 2

GMP-2

GMP-1

A1L2-23 A1L2-25

BT-2

BT-1

POWER FOR HEAT TAPE FOR

CHILLED WATER PIPING.

WH-2

A1L2-15

EF-1

A1L1-14

48" AFF

48" AFF

48" AFF

48" AFF

48" AFF

48" AFF

48" AFF

48" AFF

48" AFF48" AFF

48" AFF

3 4

A1L4-13

A1L2-30

DHWP-1

L L

LL

L L

L

L L

L

L

LLL

L

L

L

L

L A1L1-17

L L L

L

L

L L

L

L

LL

L

L

L

L

L

L

A1L1-37

POWER FOR DDC

ELECTRIFIED PANIC DEVICE

A1L1-14 A1L1-14

GENERAL NOTES:

1. PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH FOR VAV BOX.

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U.

S.

A

RM

Y

EN

G

IN

EE

R

DI

ST

RI

CT

CO

RP

S

O F

EN

G

IN

EE

RS

FO

RT

W

O

RT

H, T

EX

AS

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ® Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/8

'-0

1/ 5/

:2

5:

P M

L

RE

CE

PT

IO

N

ST

AT

IO

N

B A

RR

A C

KS

(R

SB

FO

R T S

IL

L , O K

AL

PH

A

BA

T T

ER

Y C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

T.

A

VE

R

Y, P

.E

T.

A

VE

R

Y, P

.E

D

AR

EN

A

. B R

O W

N C

H

IE

F, E

LE

C

TR

IC

AL

S

EC

TI

O N

1EP103

PO

W

ER

P

LA

N

ST

F L O

O R

- A

RE

A C

D . B

R O

W N

1/8" = 1'-0"1 POWER PLAN 1ST FLOOR - AREA C

D

E

KEY PLAN

C A

B

04 8 16268

PLAN

NORTH

KEYED NOTES

# NOTES

1 PROVIDE 3 #500 KCMIL & 1 #1/0 GND IN 4" CONDUIT. PROVIDE

400A, 600V, 3P, NEMA 3R SAFETY SWITCH.

2 PROVIDE 3 #12 & 1 #12 GND IN 1/2" CONDUIT. PROVIDE 30A,

600V, 3P, NEMA 1 SAFETY SWITCH.

3 PROVIDE 30A, 240V, 2P, NEMA 3R SAFETY SWITCH.

4 PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH.

6 PROVIDE 3 #10 & 1 #10 GND IN 3/4" CONDUIT. PROVIDE 30A,

600V, 3P, NEMA 1 SAFETY SWITCH.

c ad d po w er to d oo rs am

Ja n

WWWWWWWWWW WWWWWWWWWW

P

G F

WP

GF

WP

GF

W P

G F

W P

G F

GF GF GF GF GF

G

FG

F

GF GF GF GF GF

G F

G F

GFGF

J

J J

J

J J

D101

VEST.

D105

LUGGAGE

D104

LUGGAGE

D107

JAN.

D112

DRY AREA

D115

LAUNDRY

D110

SHOWERS

D111

DRY AREA

D109

SHOWERS

D114

TOILETS

D113

TOILETS

D108

JAN.

D103

SLEEPING BAY

D116

LAUNDRY

D106

SLEEPING BAY

D118

STAIR

D102

CORRIDOR

D119

ELEC.

GF

A1L10-19

GF

A1L10-19

GF

A1L10-2

GF

A1L10-2

GF

A1L10-18

GF

A1L10-18

GF

A1L10-16

GF

A1L10-16

GF

A1L10-14

GF

A1L10-14

A1L12A1L11

TA1C

A1L9

A1 L9

-2

A1L9-28A1L9-28

A1 L9

-2

A1 L9

-2

A1L9-26

A1L9-26

A1L9-30

A1L9-30

A1L9-30

A1L9-25

A1L10-11

A1L10-11

A1L10-11

A1L10-11

A1L10-11

A1L9-29

A1L9-29

A1L9-29A1L9-27

A1L9-27

A1L9-27

A1L9-27

A1L10-11A1L9-27 A1L9-26 A1L9-26

A1L9-25 A1L9-25A1L9-35A1L9-35 A1L9-35

A1L9-35 A1L9-35 A1L9-25 A1L9-25A1L9-30

A1 L9

-2

G F

A1 L1

-3

G F

A1 L1

-3

A1L9-29

1EP401

1EP403

48" AFF48" AFF

A1LLD

A1L10

A1L9-34

A1L9-36

A1L9-36

A1L9-36 A1L9-36

A1L9-36

A1L9-36

A1L9-36 A1L9-36

T

VAV-SA-D1-04

VAV-OA-D1-02

VAV-SA-D1-03 VAV-SA-D1-01

VAV-SA-D1-02

VAV-OA-D1-01

VAV-OA-E1-03

VAV-OA-D1-03

FCU-D118

DSS-D218

DSS-D119

A1L10-8,10

DSS-C125

DSS-C126

A1L2-14,16

A2L7-33,35

A1L2-20,22 R

R

R R A1L10-11 A1L9-30

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

A1L9-28

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

A1L9-35 A1L9-35

ELECTRIFIED PANIC DEVICE

A1L9-25

ELECTRIFIED

PANIC DEVICE

ELECTRIFIED PANIC DEVICE

ELECTRIFIED PANIC DEVICE

A1L9-25 A1L9-25

GENERAL NOTES:

1. PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH FOR VAV BOX.

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U.

S.

A

RM

Y

EN

G

IN

EE

R

DI

ST

RI

CT

CO

RP

S

O F

EN

G

IN

EE

RS

FO

RT

W

O

RT

H, T

EX

AS

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ® Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/8

'-0

1/ 5/

:2

6:

P M

L

RE

CE

PT

IO

N

ST

AT

IO

N

B A

RR

A C

KS

(R

SB

FO

R T S

IL

L , O K

AL

PH

A

BA

T T

ER

Y C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

T.

A

VE

R

Y, P

.E

T.

A

VE

R

Y, P

.E

D

AR

EN

A

. B R

O W

N C

H

IE

F, E

LE

C

TR

IC

AL

S

EC

TI

O N

1EP104

PO

W

ER

P

LA

N

ST

F L O

O R

- A

RE

A D

D . B

R O

W N

1/8" = 1'-0"1 POWER PLAN 1ST FLOOR - AREA D

D

E

KEY PLAN

C A

B

04 8 16268

PLAN

NORTH

KEYED NOTES

# NOTES

1 PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH.

2 PROVIDE 30A, 240V, 2P, NEMA 3R SAFETY SWITCH.

c ad d po w er to d oo rs am

Ja n c c c

WP

GF

W P

G F

WP

GF

WP

GF

W P

G F

W P

G F

GF GF GF GF GF

G F

G F

GF GF GF GF GF

G F

TV

TV

GF GF

F F

J

J J J J

J J

J

E101

STAIR

D101

VEST.

E106

JAN.

E103

LUGGAGE

E104

LUGGAGE

E114

LAUNDRY

E111

DRY AREA

E109

SHOWERS

E108

SHOWERS

E110

DRY AREA

E113

TOILETS

E112

TOILETS

E107

JAN.

E115

LAUNDRY

E116

VEST.

E117

D.I. OFF.

E118

CLOSET

D102

CORRIDOR

E119

TLT.

GF

A1L10-15

GF

A1L10-15

GF

A1L10-13

GF

A1L10-13

GF

A1L10-17

GF

A1L10-17

GF

A1L10-9

GF

A1L10-9

GF

A1L10-12

GF

A1L10-12

GF

A1L10-7

E105

SLEEPING BAY

E102

SLEEPING BAY

A1L13A1L14

TA1C

A1L1-12

A1 L9

-2

A1L9-20 A1L9-20

A1 L9

-2

A1 L9

-2

A1L9-23 A1L9-31 A1L9-31

A1L9-31

A1L9-31

A1L9-31

A1L9-25

A1L9-23

A1L9-23

A1L9-23

A1L9-23

A1L9-24 A1L9-24A1L9-24A1L9-33 A1L9-33A1L9-33

A1L9-22 A1L9-22 A1L9-21

A1L9-22 A1L9-21

A1L9-22

A1L9-22

A1L9-22

A1L9-21

A1L9-21

A1L9-21

A1L9-24A1L9-24A1L9-33A1L9-33 A1L9-24

A1L9-25

A1L9-25

A1L10-6A1L10-6

A1L10-6

A1L10-6 A1L10-4

A1L10-4

A1L10-4

A1L1-34

A1L10-4

1EP401

48" AFF48" AFF

A1L10-5

A1L10-4 A1L9-32

A1L9-36 A1L9-36

A1L9-36 A1L9-36A1L9-36 A1L9-36

A1L9-36

A1L9-36 A1L9-36

A1L9-36

A1L9-36

T VAV-OA-E1-03

VAV-OA-D1-03

VAV-SA-E1-03

VAV-SA-E1-02

VAV-SA-E1-01

VAV-SA-E1-04

VAV-OA-E1-02

VAV-SA-E1-06

VAV-OA-E1-01

VAV-SA-E1-05

FCU-E101

VAV-SA-E1-07

A1L9-23A1L9-21

48" AFF

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

ALL CIRCUITS IN THIS ROOM SHALL BE

ON ARC FAULT CIRCUIT BREAKERS.

A1L9-19 A1L9-19

L

L

L

L L

L

LL

ELECTRIFIED PANIC DEVICE

A1L10-4

A1L9-33 A1L9-33

ELECTRIFIED PANIC DEVICE ELECTRIFIED PANIC DEVICE ELECTRIFIED PANIC DEVICE ELECTRIFIED PANIC DEVICE

A1L9-24 A1L9-24

A1L9-25

A1L9-25

ELECTRIFIED

PANIC DEVICE

ELECTRIFIED

PANIC DEVICE

ELECTRIFIED

PANIC DEVICE

A1L9-25

GENERAL NOTES:

1. PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH FOR VAV BOX.

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U.

S.

A

RM

Y

EN

G

IN

EE

R

DI

ST

RI

CT

CO

RP

S

O F

EN

G

IN

EE

RS

FO

RT

W

O

RT

H, T

EX

AS

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ® Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/8

'-0

1/ 5/

:2

6:

P M

L

RE

CE

PT

IO

N

ST

AT

IO

N

B A

RR

A C

KS

(R

SB

FO

R T S

IL

L , O K

AL

PH

A

BA

T T

ER

Y C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

T.

A

VE

R

Y, P

.E

T.

A

VE

R

Y, P

.E

D

AR

EN

A

. B R

O W

N C

H

IE

F, E

LE

C

TR

IC

AL

S

EC

TI

O N

1EP105

PO

W

ER

P

LA

N

ST

F L O

O R

- A

RE

A E

D . B

R O

W N

1/8" = 1'-0"1 POWER PLAN 1ST FLOOR - AREA E

D

E

KEY PLAN

C A

B

04 8 16268

PLAN

NORTH

KEYED NOTES

# NOTES

1 PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH.

c ad d po w er to d oo rs am

Ja n c c c

GF GF GF GF GF

FG

F

GF GF GF GF GF

G F

G F

G F

GFGF

J J J J

J

A207

JAN

A203

LUGGAGE

A202

SLEEPING BAY

A216

LAUNDRY

A215

LAUNDRY

A214

TOILETS

A213

TOILETS

A208

JAN

A218

ELEC

A204

LUGGAGE

A205

SHPS LDR

A217

STAIR

A201

CORRIDOR

A209

SHOWERS

A212

DRY AREA

A210

SHOWERS

A206

SLEEPING BAY

A211

DRY AREA

GF

A2L1-33

GF

A2L1-33

GF

A2L2-2

GF

A2L2-2

GF

A2L2-4

GF

A2L2-4

GF

A2L2-1

GF

A2L2-1

GF

A2L2-3

GF

A2L2-3

TA2A

A2L1

A2L2

A2L3A2L4

1EP402

1EP403

48" AFF48" AFF

A2L1-20

A2L1-20

A2L1-20

A2L1-20

A2L1-20

A2L1-31

A2L1-26

A2L1-26

A2L1-26

A2L1-26

A2L1-26

A2L1-23

A2L1-23

A2L1-23

A2L1-23 A2L1-30

A2L1-30

A2L1-30

A2L1-27

A2L1-30A2L1-30 A2L1-20 A2L1-23

A2L1-31 A2L1-31 A2L1-27

A2L1-27 A2L1-27

A2L1-27 A2L1-27 A2L1-31 A2L1-31 A2L1-27

A2 L2

-1

A2L1-22A2L1-22

A2LLA

T

A2L2-13

A2L2-13

A2L2-13

A2L2-13

A2L2-13

A2L2-13

A2L2-13

A2L2-13

VAV-SA-A2-02

VAV-OA-A2-01

VAV-SA-A2-01

VAV-OA-A2-03

VAV-OA-B2-03

VAV-SA-A2-03

VAV-SA-A2-04

VAV-OA-A2-02

ALL CIRCUITS IN THIS ROOM SHALL

BE ON ARC FAULT CIRCUIT BREAKERS.

ALL CIRCUITS IN THIS ROOM SHALL

BE ON ARC FAULT CIRCUIT BREAKERS.

A2L1-26 A2L1-20

ELECTRIFIED PANIC DEVICE

A2L1-27A2L1-27

ELECTRIFIED PANIC DEVICE

A2L1-31 ELECTRIFIED PANIC DEVICE

A2L1-31

ELECTRIFIED PANIC DEVICE

A2L1-31

ELECTRIFIED PANIC DEVICE

GENERAL NOTES:

1. PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH FOR VAV BOX.

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U.

S.

A

RM

Y

EN

G

IN

EE

R

DI

ST

RI

CT

CO

RP

S

O F

EN

G

IN

EE

RS

FO

RT

W

O

RT

H, T

EX

AS

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ® Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/8

'-0

1/ 5/

:2

6:

P M

L

RE

CE

PT

IO

N

ST

AT

IO

N

B A

RR

A C

KS

(R

SB

FO

R T S

IL

L , O K

AL

PH

A

BA

T T

ER

Y C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

T.

A

VE

R

Y, P

.E

T.

A

VE

R

Y, P

.E

D

AR

EN

A

. B R

O W

N C

H

IE

F, E

LE

C

TR

IC

AL

S

EC

TI

O N

1EP106

PO

W

ER

P

LA

N

ND

F L O

O R

- A

RE

A A

D . B

R O

W N

1/8" = 1'-0"1 POWER PLAN 2ND FLOOR - AREA A

D

E

KEY PLAN

C A

B

04 8 16268

PLAN

NORTH

c ad d po w er to d oo rs am

Ja n c c

F

G F

GF GF GF GF GF

G F

G F

GF

G F

TV

GFGF

J

J J J J

J

B201

STAIRS

B203

LUGGAGE

B207

JAN

B216

LAUNDRY

B215

LAUNDRY

B213

TOILETS

B208

JAN

B217

LUGGAGE

B219

CLOSET

B218

D.I. OFF.

B204

LUGGAGE

B205

SHPS LDR

A201

CORRIDOR

B220

TLT

B210

SHOWERS

B212

DRY AREA

B214

TOILETS

B209

SHOWERS

B211

DRY AREA

GF

A2L1-25

GF

A2L1-25

GF

A2L2-6

GF

A2L2-6

GF

A2L2-8

GF

A2L2-8

GF

A2L2-5

GF

A2L2-5

GF

A2L2-7

GF

A2L2-7

GF

A2L2-12

A2L5 A2L6

1EP402

48" AFF48" AFF

A2L1-19 A2L1-19 A2L1-21

A2L1-21

A2L1-21

A2L1-21

A2L1-21

A2L1-19

A2L1-19

A2L1-19

A2L1-19

A2L1-28 A2L1-28A2L1-28A2L1-32 A2L1-32A2L1-32

A2L1-29 A2L1-24 A2L1-24

A2L1-29 A2L1-24

A2L1-29

A2L1-29

A2L1-29

A2L1-24

A2L1-24

A2L1-24

A2L1-28A2L1-28A2L1-32A2L1-32 A2L1-32

A2L1-29

A2L2-9

A2L2-9 A2L2-11

A2L2-11

A2L1-22

A2L1-22A2L1-22

A2L1-22

A2L2-11

A2L2-11

T

A2L2-10

A2L2-13

A2L2-13

A2L2-13 A2L2-13 A2L2-13

A2L2-13

A2L2-13

A2L2-13 A2L2-13

A2L2-13

A2L2-13

VAV-OA-B2-03

VAV-SA-B2-01

VAV-SA-B2-02

VAV-SA-B2-03

VAV-SA-B2-04

VAV-SA-B2-07

VAV-OA-B2-01

VAV-SA-B2-05

VAV-OA-B2-02

VAV-SA-B2-06

ALL CIRCUITS IN THIS ROOM SHALL

BE ON ARC FAULT CIRCUIT BREAKERS.

ALL CIRCUITS IN THIS ROOM SHALL

BE ON ARC FAULT CIRCUIT BREAKERS.

48" AFF

A2L1-19A2L1-24

L

L

L

A2L2-9

A2L2-9 L

ELECTRIFIED PANIC DEVICE

A2L1-32A2L1-32

A2L1-32

ELECTRIFIED PANIC DEVICE ELECTRIFIED PANIC DEVICE

A2L1-28

ELECTRIFIED PANIC DEVICE

A2L1-31

ELECTRIFIED PANIC DEVICE

GENERAL NOTES:

1. PROVIDE 20A, 125V, 1P, S/N, NEMA 1 SAFETY SWITCH FOR VAV BOX.

SHEET

SEQUENCE

NUMBER

1 2 3 4 5

D ra w n by

D es ig ne d by

Su bm itt ed b y:

Fi le

N am e:

D at e :

C on t ra ct

N o.

So lic ita tio n N o.

U.

S.

A

RM

Y

EN

G

IN

EE

R

DI

ST

RI

CT

CO

RP

S

O F

EN

G

IN

EE

RS

FO

RT

W

O

RT

H, T

EX

AS

R ev ie w ed b y:

D

C

B

A

Pl ot

S ca le

Pl ot

D at e:

R ev

Sy m b o l

D es c r ip tio n

Tr ac k i ng

N o.

Ac tio n D at e

EN

G

IN

EE

R

IN

G

C O

N

ST

R U

C

TI

O N

D

IV

IS

IO

N

EN

G

IN

EE

R

IN

G

B R

AN

C

H

US Army Corps of Engineers ® Tulsa District

US Army Corps of Engineers ®

Fort Worth District

/8

'-0

1/ 5/

:2

6:

P M

L

RE

CE

PT

IO

N

ST

AT

IO

N

B A

RR

A C

KS

(R

SB

FO

R T S

IL

L , O K

AL

PH

A

BA

T T

ER

Y C O

M

PL

EX

P

H A

SE

II

O C

TO

BE

R

W

2B V-

-R

T.

A

VE

R

Y, P

.E

T.

A

VE

R

Y, P

.E

D

AR

EN

A

. B R

O W

N C

H

IE

F, E

LE

C

TR

IC

AL

S

EC

TI

O N

1EP107

PO

W

ER

P

LA

N

ND

F L O

O R

- A

RE

A B

D . B

R O

W N

1/8" = 1'-0"1 POWER PLAN 2ND FLOOR - AREA B

D

E

KEY PLAN

C A

B

04 8 16268

PLAN

NORTH

c ad d po w er to d oo rs am

Ja n c

FG

F

GF GF GF GF GF

G F G F

G F

GF GF

J

J J J J

D203

LUGGAGE

D207

JAN

D216

LAUNDRY

D215

LAUNDRY

D214

TOILETS

D213

TOILETS

D208

JAN

D217

STAIRS

D218

ELEC

D201

CORRIDOR

D205

SHPS LDR

D204

LUGGAGE

D206

SLEEPING BAY

D211

DRY AREA

D209

SHOWERS

D…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it.