RFI 1.pdf

PDF 307 KB Posted

Attached to
FE Walter Dam Intake Tower Roof Repair
Solicitation number
W912BU-24-R-0021
Issued by

About this file

This document is a Request for Information (RFI) related to a federal contract opportunity for the repair of the roof at the FE Walter Dam Intake Tower. Key details include:

The contract is subject to Davis-Bacon wage rates for Luzerne County, PA, but no bonding is required. Bidders are not required to submit past performance, cost breakdowns, or technical information with their quotes; only the quote itself will be reviewed. A site visit is scheduled for April 12th. Evaluation will be based on the criteria in FAR clause 52.212-2. The solicitation number is W912BU-24-R-0021, and quotes are due by 11:00 AM EDT on May 1st, 2024. Questions can be submitted to the contract specialist by April 22nd. There are no statewide Pennsylvania general contractor license or certification requirements, but the contractor must be fully insured and registered on SAM.gov.

View the file

Other files

File Type Posted
Davis Bacon PA20240095.pdf PDF
W912BU-24-R-0021.pdf PDF
24-R-0021 Drawings.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

1. Can you please advise of the es mated magnitude? The contractor is responsible to determine project magnitude based on the solicita on and drawings provided.

2. Can you please provide the applicable wage determina on number for this solicita on?

This project is subject to Davis Bacon Wage Rates for Luzerne County, PA. A copy of the most recent wage determina on is a ached.

3. Can you please advise if a bid bond and/or payment and performance bonds will be required? No bonding is required on this effort.

4. Can you please advise what the bid submission requirements are (ie. past performance, cost breakdown, technical info, etc.)? There are no bid submi als beyond the quote.

A er award, contractor is required to develop an Accident Preven on Plan (APP) and follow the PWS for technical requirements.

5. Is there a site visit scheduled for this or do we make our own arrangements to look at it?

Friday April 12 @ 0900. Meet at the project office, 146 Francis E. Walter Dam Road, White Haven PA, 18661.

6. For the submission of our quote, do we only need to submit the quote on our own pricing sheet or should we include our coversheet and also business profile? Only the quote will be reviewed for this effort.

7. What are the license requirements for this specific project? There are no statewide Pennsylvania general contractor license or cer fica on requirements. However, the Contractor must be fully insured and registered on SAM.Gov.

8. Is the evalua on LPTA or Best Value? Evalua on factors are addressed in the solicita on clause 52.212-2.

File details come from the government source that posted it. Updated .