This document contains the drawings and specifications for the rehabilitation project of the restrooms at the Fort Randall Powerhouse in South Dakota. The project involves the replacement of plumbing, lighting fixtures, floors, ceilings, and doors to meet ADA standards. The solicitation number is W9128F24B0007, with an estimated construction magnitude between $250,000 and $500,000. The primary NAICS code is 236220 - Commercial and Institutional Building Construction. The bid offers are due by August 23, 2024, and the bid opening will be conducted on the same day. The project location is Fort Randall Dam in Pickstown, South Dakota. Interested contractors are required to be registered in the SAM.gov database to access the solicitation documents.
View the file
Other files
Show all 12
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
4A
H
J
H
J
6 4A 754 6
A N
S I
D
R E
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W
F
B
/1
/2
O M
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
IC
T
F
IL
E
N U
M B
E R
B
G O
R U
P
F L
E C
T E
D C
E
IL
IN
G
P L
A N
E
L E
V A
T
IO
N
.0
A-160
M
B
IE
G E
R T
B
G O
R
A
-1
.d g n
B
IE
G E
S
P
D
:4
:2
A M
/2
/2
F R
A
-1
.d g n
TOILET
WOMENS
CORRIDOR
ENTRY
TOILET
MENS
LOBBY
ELEVATOR
LOBBY
ELEVATOR
CORRIDOR
ENTRY
RESTROOM
WOMENS
TOILET
WOMENS
TOILET
MENS
ENTIRELY
CORRIDOR CEILING
AND PAINT ENTRY
SURFACE PREPARE,
IMPERFECTIONS,
HOLES AND REPAIR
CEILING - PATCH
EXISTING PLASTER
FIXTURES - SEE ELEC.
EXISTING LIGHTING
REMOVE AND SCRAP
FIXTURES - SEE ELEC.
EXISTING LIGHTING
REMOVE AND SCRAP
- SEE ELEC.
LIGHT FIXTURES
SCRAP EXISTING
REMOVE AND
SEE MECH
SEE MECH
ABOVE CEILING WORK
AS REQUIRED TO ACCESS
SUSPENSION SYSTEM
PLASTER CEILING AND
PORTIONS OF EXISTING
REMOVE AND SCRAP
SCRAP SUPPORT STRUCTURE
ASSEMBLY. REMOVE AND
PLASTER WALL/BULKHEAD
EXISTING SUSPENDED
REMOVE AND SCRAP
SUPPORT STRUCTURE
ASSEMBLY. VERIFY
PLASTER WALL/BULKHEAD
EXISTING SUSPENDED
REMOVE AND SCRAP
CEILING
ACOUSTICAL TILE
NEW SUSPENDED
- SEE ELEC.
FIXTURES - TYP.
NEW LIGHT
- SEE ELEC.
FIXTURES - TYP.
NEW LIGHT
ROOM
MOTHERS
NURSING
- SEE ELEC.
FIXTURES - TYP.
NEW LIGHT
- SEE ELEC.
FIXTURES - TYP.
NEW LIGHT
- SEE ELEC.
FIXTURES - TYP.
NEW LIGHT
GENERAL NOTES:
BE REMOVED AND SCRAPPED.
TILE CEILING BELOW THE SUSPENDED PLASTER CEILING THAT WILL
6. IN THE WOMENS TOILET THERE IS AN EXISTING SUSPENDED ACOUSTICAL
WALLS IF APPLICABLE,
5. SEE FIRE PROTECTION DRAWINGS FOR LOCATIONS OF FIRE RATED
4. SEE A-600 FOR CEILING HEIGHTS.
FOR ROOM NAMES AND NUMBERS
3. SEE FLOOR PLANS A-400, A-401, A-402 AND A-600
FINISHES.
NEW WORK. REPAIR AND FINISHING TO MATCH EXISTING ADJACENT
WILL REMAIN IN A FINISHED ROOM IN LOCATIONS AFFECTED BY
2. PATCH, REPAIR, AND FINISH ALL EXISTING CEILINGS THAT
AND AREAS IDENTIFIED ON THE ELECTRICAL DRAWINGS.
1. REMOVE EXISTING LIGHT FIXTURES IN THE TOILET ROOMS
ABOVE CEILING WORK
AS REQUIRED TO ACCESS
SUSPENSION SYSTEM
PLASTER CEILING AND
PORTIONS OF EXISTING
REMOVE AND SCRAP
ABOVE CEILING WORK
AS REQUIRED TO ACCESS
SUSPENSION SYSTEM
PLASTER CEILING AND
PORTIONS OF EXISTING
REMOVE AND SCRAP
SYSTEM
SUSPENSION
CEILING AND
ACOUSTIC TILE
SUSPENDED
SCRAP EXISTING
REMOVE AND
CEILING
ACOUSTICAL TILE
NEW SUSPENDED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E
EXISTING REFLECTED CEILING PLAN - DEMOLITION - ELEV. 1273.0 - LEVEL 1 NEW REFLECTED CEILING PLAN - ELEV. 1273.0 - LEVEL 1
SCALE: ¼''= 1'-0"
0 4'4' 2'
NORTH
G1 G12
A
M
G E
N E
R A
L R
E V
IS
IO
N S
-2
-2
J
4A 754 6
H
J
4A 754 6
A N
S
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W
F
B
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
B
G O
R
F L
E C
T E
D C
E
IL
IN
G
P L
A N
E
L E
V A
T
IO
N
.0
A-161
M
B
IE
G E
R T
B
G O
R
A
-1
.d
B
IE
G E
P
D
:1
:5
P
M
/2 /2
F R
A
-1
.d g n
PLUMBING CHASE
EXTEND EXISTING
TOILET
WOMENS
LOBBY
ELEVATOR
RESTROOM
WOMENS
TOILET
MENS
ENTIRELY
LOBBY CEILING
AND PAINT ELEVATOR
SURFACE PREPARE,
IMPERFECTIONS,
HOLES AND REPAIR
CEILING - PATCH
EXISTING PLASTER
CEILING
ACOUSTICAL TILE
NEW SUSPENDED
SEE MECH NEW LIGHT FIXTURES
SUPPORT STRUCTURE
ASSEMBLY. VERIFY
PLASTER WALL/BULKHEAD
EXISTING SUSPENDED
REMOVE AND SCRAP
FIXTURES
EXISTING LIGHTING
REMOVE AND SCRAP
FIXTURES
LIGHTING
SCRAP EXISTING
REMOVE AND
FIXTURES
EXISTING LIGHTING
REMOVE AND SCRAP
SEE MECH
SEE MECH
LOBBY
ELEVATOR
RESTROOM
WOMENS
TOILET
WOMENS
TOILET
MENS
- SEE ELEC.
NEW LIGHT FIXTURES
GENERAL NOTES:
WALLS IF APPLICABLE,
7. SEE FIRE PROTECTION DRAWINGS FOR LOCATIONS OF FIRE RATED
6. SEE A-600 FOR CEILING HEIGHTS.
FOR ROOM NAMES AND NUMBERS
5. SEE FLOOR PLANS A-400, A-401, A-402 ANDA-600
PER SPEC. 07 84 00
FIRE RATED WALLS SHALL BE SEALED WITH FIRESTOPPING MATERIAL.
4. ALL PENETRATIONS THROUGH CONCRETE FLOOR SLABS AND
FOR ALL VENTILATION AND PLUMBING REQUIREMENTS.
OTHERWISE NOT BE ACCESSIBLE. SEE MECHANICAL DRAWINGS
THAN IN SUSPENDED ACOUSTICAL CEILING, AND THAT WOULD
AIR SPLITTER THAT IS LOCATED ABOVE THE CEILING. OTHER
EACH VALVE, FLOW INCICATOR, CLEAN-OUT, FAN, DAMPER OR
3. ACCESS PANELS SHALL BE INSTALLED DIRECTLY BELOW
FINISHES.
NEW WORK. REPAIR AND FINISH TO MATCH EXISTING ADJACENT
WILL REMAIN IN A FINSIHED ROOM IN LOCATIONS AFFECTED BY
2. PATCH, REPAIR, AND FINISH ALL EXISTING CEILINGS THAT
AND AREAS IDENTIFIED ON THE ELECTRICAL DRAWINGS.
1. REMOVE EXISTING LIGHT FIXTURES IN THE TOILET ROOMS
ABOVE CEILING WORK - TYP.
AS REQUIRED TO ACCESS
SUSPENSION SYSTEM
PLASTER CEILING AND
PORTIONS OF EXISTING
REMOVE AND SCRAP
ROOF ACCES HATCH
REMOVE EXISTING
ABOVE CEILING WORK - TYP.
AS REQUIRED TO ACCESS
SUSPENSION SYSTEM
PLASTER CEILING AND
PORTIONS OF EXISTING
REMOVE AND SCRAP
ABOVE CEILING WORK - TYP.
AS REQUIRED TO ACCESS
SUSPENSION SYSTEM
PLASTER CEILING AND
PORTIONS OF EXISTING
REMOVE AND SCRAP
CEILING
ACOUSTICAL TILE
NEW SUSPENDED
CEILING
ACOUSTICAL TILE
NEW SUSPENDED
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E
EXISTING REFLECTED CEILING PLAN - DEMOLITION - ELEV. 1291.0 - LEVEL 2 NEW REFLECTED CEILING PLAN - ELEV 1291.0 - LEVEL 2 F1 F11
SCALE: ¼''= 1'-0"
0 4'4' 2'
NORTH
A M
G E
N E
R A
L R
E V
IS
IO
N S
-2
-2
4A
J
H
J
6 4A 754 6
101 104
B14 B16
B6 B2
A-411
E1 G1
K1 M1
A-410 E5
G5 K5
M5
A-410
1'-7"
K11 E11
A-411
G11 E16
K2 E2
A-411
G2 E5
9'-2"
4'-1" 3'-4"
6'-4"
2'-0"
4'-8"
8'-8"
1'-4"
5'-6"
6'-1"4'-10"4'-10"10'-8�"
4"
A N
S
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L L D
A M
S
O U
T H
D A
K O
T A
W F
B
/1
/2
A H
A
N E
C
A P
IT
O
L A
V E
O M
A H
A D
IS
T
R
E
N U
M B
E R
B G
O R
U P
L E
V E
L
B
A S
IC
P
L A
N S
E
L E
V A
T
IO
N
.0
E N
L A
R G
E D
T O
IL
E
T R
O O
M
A-400
M
B
IE
G E
R T
B G
O R
A
-4 .d
B
IE
G E
P
D
:4
:5
P M
/2
/2
F R
A
-4 .d g n
101 102
ROOM
MOTHERS
NURSING
TOILET
WOMENS
CORRIDOR
ENTRY
TOILET
MENS
LOBBY
ELEVATOR
2.
1A.
1.
2.
7.
15.
16.
10.
8.
13.
10.
17.
18.
15.
5.
9.
8.
6.
3.
5.
4.
5.11.
16.
12.
15.
17.18.
10.
8.
13.
10.16.
3.
3A. 1.
22.
21.
9.
13.
14.
19.
22.
21.
24.
12.
5.
6.
16.
10.
9.
11.
6. 5. 6.4
16.
17.
18.
17.
22.
21.
24.
18.
9.
13.
19.
13.
11.
9.
10.
4.
7.
LOBBY
ELEVATOR
CORRIDOR
ENTRY
RESTROOM
WOMENS
TOILET
WOMENS
TOILET
MENS
4.
KEYED NOTES - REMOVAL AND DEMOLITION
KEYED NOTES - NEW CONSTRUCTION
NEW FULL HEIGHT STAINLESS STEEL CORNER GUARDS. SEE A-600 FOR ADDITIONAL INFORMATION.26.
NEW STEEL STUD WALL - SEE WALL TYPE 1 ON SHEET A-500.25.
NEW SUSPENDED ACOUSTICAL TILE CEILING ASSEMBLY AT 9'-0" ABOVE FINISH FLOOR - TYP.24.
NEW PAINT23.
NEW CERAMIC TILE WAINSCOT AND BASE.22.
NEW CERAMIC TILE FLOOR ON SETTING BED.21.
WALL WITH FACE OF COUNTER.
2-1/2" STEEL STUD FURRING, CERAMIC TILE, AND PLASTER TO FLUSH 20.
NEW TOILET PARTITION.19.
NEW URINAL.18.
NEW URINAL SCREEN.17.
EXISTING ELECTRIC HAND DRYER TO BE REINSTALLED AFTER TILE INSTALLATION.16.
NEW MINI FRIDGE UNDER COUNTER TOP (NOT IN CONTRACT)15.
NEW SANITARY NAPKIN DISPOSER (SND).14.
NEW TOILET TISSUE DISPENSER (TTD).13.
NEW LAVATORY 12.
NEW GRAB BAR 2.11.
NEW GRAB BAR 1.10.
NEW TOILET.9.
ALL WALLS AND CEILING IN THE ENTRY CORRIDOR 103 TO MATCH EXISTING.
PLASTER OR GYPSUM BOARD AND FINISHED TO CREATE A SINGLE PLANE WALL. PAINT
TILE WAS REMOVED. NEW PLASTER OR GYPSUM BOARD TO BE FLUSH WITH EXISTING
NEW PLASTER OR GYPSUM BOARD TO BE INSTALLED WHERE THE EXISTING CERAMIC 8.
NEW WALL MOUNTED PAPER TOWEL DISPENSER/WASTE RECEPTACLE (PTD/WR).7.
NEW MIRROR (MG).6.
NEW SOAP DISPENSER (SD).5.
NEW COUNTERTOP 4.
TO MATCH EXISTING ADJACENT FINISHES.
PLASTER WALL, CERAMIC TILE BASE, CERAMIC TILE WALL, AND CERAMIC TILE FLOOR AND ALL AFFECTED FINISHES INFORMATION FOR THE REINSTALLATION OF EXISTING ALUMINUM DOORS. FILL IN, PATCH, REPAIR EXISTING "KEYED NOTES - REMOVAL AND DEMOLITION" THIS SHEET AND THE DOOR SCHEDULE A-600 FOR ADDITIONAL DOOR FRAME, ROUGH BUCK, ALUMINUM EXPANSION WING CASING, PLINTH, AND DOOR HARDWARE. SEE THE
EXISTING REINSTALLED-RELOCATED ALUMINUM DOOR (FROM EXISTING WOMEN'S TOILET 102), ALUMINUM 3B.
TO MATCH EXISTING ADJACENT FINISHES.
PLASTER WALL, CERAMIC TILE BASE, CERAMIC TILE WALL, AND CERAMIC TILE FLOOR AND ALL AFFECTED FINISHES INFORMATION FOR THE REINSTALLATION OF EXISTING ALUMINUM DOORS. FILL IN, PATCH, REPAIR EXISTING "KEYED NOTES - REMOVAL AND DEMOLITION" THIS SHEET AND THE DOOR SCHEDULE A-600 FOR ADDITIONAL DOOR FRAME, ROUGH BUCK, ALUMINUM EXPANSION WING CASING, PLINTH, AND DOOR HARDWARE. SEE THE
EXISTING REINSTALLED-RELOCATED ALUMINUM DOOR (FROM EXISTING ENTRY CORRIDOR 103), ALUMINUM 3A.
MATCH EXISTING ADJACENT FINISHES.
PLASTER WALL, CERAMIC TILE BASE, CERAMIC TILE WALL, AND CERAMIC TILE FLOOR AND ALL AFFECTEDTO INFORMATION FOR THE REINSTALLATION OF EXISTING ALUMINUM DOORS. FILL IN, PATCH, REPAIR EXISTING "KEYED NOTES" - REMOVAL AND DEMOLITION" THIS SHEET AND THE DOOR SCHEDULE A-600 FOR ADDITIONAL DOOR FRAME, ROUGH BUCK, ALUMINUM EXPANSION WING CASING, PLINTH, AND DOOR HARDWARE. SEE THE
EXISTING REINSTALLED-RELOCATED ALUMINUM DOOR (FROM EXISTING MEN'S TOILET 104), ALUMINUM 3.
NOT USED. 2.
CONDITION AND GROUT COLOR.
DOOR AND FRAME. PATCH AND REPAIR EXISTING PLASTER, AND FLOOR TILE TO MATCH EXISTING
EXTEND WALL TO MATCH EXISTING AND REINFORCE TO RECEIVE REINSTALLED ALUMINUM 1.
REMOVE WALL.WALL BEING REMOVED HAS EXISTING CERAMIC TILE THAT WILL NEED TO BE REMOVED AND SCRAPPED. 24.
DOOR SALVAGED FROM THE WOMEN'S TOILET ROOM.
DEMO INDICATED SECTION OF EXISTING WALL TO CREATE NEW DOOR OPENING IN EXISTING WALL TO FIT EXISTING 23.
ALL ITEMS SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITIONS.
REMAIN, AND ALL COMPONENTS THAT WILL BE REINSTALLED OR ADJACENT TO THE EXISTING FINISHES. IF DAMAGE OCCURS OPENING. GREAT CARE SHALL BE TAKEN TO NOT DAMAGE EXISTING DOOR ASSEMBLY, ALL EXISTING ADJACENT FINISHES TO ASSEMBLY FROM EXISTING WOMEN'S TOILET 102 (TO BE REINSTALLED TO NEW NURSING MOTHER'S ROOM 102) IN ALTERED EXPANSION WING CASING, PLINTH, DOOR THRESHOLD, ALL APPLICABLE HARDWARE DOOR HARDWARE, AND DOOR
REMOVE AND SALVAGE FOR REINSTALLATION EXISTING ALUMINUM DOOR, DOOR FRAME, ROUGH BUCK, ALUMINUM 22A.
SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING CONDITIONS.
AND ALL COMPONENTS THAT WILL BE REINSTALLED OR ADJACENT TO THE EXISTING FINISHES. IF DAMAGE OCCURS ALL ITEMS GREAT CARE SHALL BE TAKEN TO NOT DAMAGE EXISTING DOOR ASSEMBLY, ALL EXISTING ADJACENT FINISHES TO REMAIN, ASSEMBLY FROM ENTRY CORRIDOR 103 (TO BE REINSTALLED TO MEN'S TOILET ROOM 104) IN ALTERED OPENING.
EXPANSION WING CASING, PLINTH, DOOR THRESHOLD, ALL APPLICABLE HARDWARE DOOR HARDWARE, AND DOOR
REMOVE AND SALVAGE FOR REINSTALLATION EXISTING ALUMINUM DOOR, DOOR FRAME, ROUGH BUCK, ALUMINUM 22.
REMOVE AND SCRAP EXISTING CEILING MOUNTED ACCESS DOOR.21.
THERMOSTAT TO BE REMOVED AND RELOCATED ONCE RENOVATION IS COMPLETE20.
(STRUCTURAL CLAY UNITS) TO RECEIVE NEW GYPSUM BOARD AND FURRING.
REMOVE AND SCRAP EXISTING CERAMIC WALL TILE AND SETTING BED DOWN TO THE STRUCTURAL WALL 19.
TOILET PARTITION SUPPORT STRUCTURE.
REMOVE AND SCRAP EXISTING SUSPENDED PLASTER WALL/BULKHEAD ASSEMBLY AT CEILING AND ASSOCIATED 18.
102 ENTIRELY. SEE ELECTRICAL DRAWINGS FOR REMOVAL OF CEILING MOUNTED ITEMS.
REMOVE AND SCRAP EXISTING SUSPENDED ACOUSTICAL TILE CEILING ASSEMBLY IN EXISTING WOMEN'S TOILET ROOM17A.
OF CEILING MOUNTED ITEMS.
ELEVATION OF THE CEILING ABOVE THE FINSIH FLOOR IS APPROXIMATELY 10'-0". SEE ELECTRICAL DRAWINGS FOR REMOVAL SHALL BE ADEQUATELY BRACED AND SUPPORTED TO REMAIN SAFELY IN PLACE INCLUDING WHERE REMOVAL OCCURED.
FOR ACCESS TO ABOVE CEILING WORK. THE EXISTING SUSPENDED PLASTER CEILING ASSEMBLY AND SUPPORTS TO REMAIN
REMOVE AND SCRAP PORTIONS OF EXISTING SUSPENDED PLASTER CEILING ASSEMBLY AND SUPPORTS AS REQUIRED 17.
FINISH FLOOR.
6'-0" ABOVE FINISH FLOOR. HEIGHT OF CERAMIC TILE WAINSCOT IN WOMEN'S RESTROOM IS APPROXIMATELY 4'-8" ABOVE TO RECEIVE NEW WALL TILE. HEIGHT OF CERAMIC TILE WAINSCOT IN MEN'S AND WOMEN'S TOILET IS APPROXIMATELY
REMOVE AND SCRAP EXISTING CERAMIC WALL TILE, COVED BASE, AND SETTING BED TO THE STRUCTURAL WALL 16.
RECEIVE NEW FLOOR TILE.
REMOVE AND SCRAP EXISTING CERAMIC FLOOR TILE AND SETTING BED TO THE STRUCTURAL FLOOR SLAB TO 15.
REMOVE AND SALVAGE EXISTING HAND DRYER AND FOOT PEDAL FOR REINSTALLATION.14.
REMOVE AND SCRAP EXISTING TOILET PARTITION AND URINAL SCREEN.13.
REMOVE AND SCRAP EXISTING URINAL.12.
REMOVE AND SCRAP EXISTING LAVATORY.11.
REMOVE AND SCRAP WALL MOUNTED TOILET FIXTURE. WITH WALL MOUNTED FLUSH VALVE.10.
REMOVE AND SCRAP EXISTING PAPER TOWEL RECEPTACLE.9.
REMOVE AND SCRAP EXISTING TOILET TISSUE DISPENSER.8.
REMOVE AND SCRAP EXISTING GLASS SHELF.7.
REMOVE AND SCRAP EXISTING LAVATORY AND VANITY/COUNTER UNIT.6.
REMOVE AND SCRAP EXISTING MIRROR.5.
REMOVE AND SCRAP EXISTING SOAP DISPENSER.4.
REMOVE AND SCRAP EXISTING PAPER TOWEL DISPENSER.3.
FLOOR TILES OR ADJACENT FINISHES.
GREAT CARE SHALL BE TAKEN IN THE REMOVAL OF THE EXISTING DOOR ASSEMBLY TO NOT DAMAGE ANY EXISTING 2.
IF DAMAGE OCCURS ALL ITEMS SHALL BE REPAIRED OR REPLACED TO MATCH EXISTING.
WALL AND FLOOR FINISHES AND ALL OTHER COMPONENTS THAT WILL REMAIN IN PLACE OR ADJACENT TO THE WORK.
WOMEN'S TOILET ROOM 101. GREAT CARE SHALL BE TAKEN TO NOT DAMAGE EXISTING DOOR ASSEMBLY, EXISTING ADJACENT EXPANSION WING CASING, PLINTH, DOOR THRESHOLD, ALL APPLICABLE DOOR HARDWARE, AND DOOR ASSEMBLY FROM
REMOVE AND SALVAGE FOR THE GOVERNMENT EXISTING ALUMINUM DOOR, DOOR FRAME, ROUGH BUCK, ALUMINUM 1A.
TO MATCH EXISTING CONDITIONS.
WILL BE REINSTALLED OR ADJACENT TO THE WORK. IF DAMAGE OCCURS ALL ITEMS SHALL BE REPAIRED OR REPLACED GREAT CARE SHALL BE TAKEN TO NOT DAMAGE EXISTING DOOR ASSEMBLY, EXISTING FINISHES AND COMPONENTS THAT ASSEMBLY FROM MEN'S TOILET ROOM 104 (TO BE REINSTALLED TO WOMEN'S TOILET ROOM 101) IN EXISTING OPENING.
EXPANSION WING CASING, PLINTH, DOOR THRESHOLD, ALL APPLICABLE HARDWARE DOOR HARDWARE, AND DOOR
REMOVE AND SALVAGE FOR REINSTALLATION EXISTING ALUMINUM DOOR, DOOR FRAME, ROUGH BUCK, ALUMINUM 1.
22A
24 21.
3.
14.
13.
13.
19.
19.
5.
11.
11.
16.
14.
13.
16.
16.
19.
19.
19.
13.
8.
13.
12.
16.
16. 11. 16.
22.
6.
12.
22. 22.
14.
22.
19.
22.
23. 25.
25.
4.
12.
15.
23.
23.
6.
5.
19.
22.
22.
12. 12.3B.
8.
8.
8.
8.
8.
26.
26.
17A.
3 3
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S
IZ
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E
G1 DEMOLITION FLOOR PLAN - ELEV. 1273.0 - LEVEL 1 NEW FLOOR PLAN - ELEV. 1273.0 - LEVEL 1
G-11
SCALE: ¼''= 1'-0"
0 4'4' 2'
NORTH
A
M
G
E N
E R
A L
R E
V
IS
IO
N
S
-2
-2
J
4A 754 6
H
J
4A 754 6
M9
A-410
M9
A-410
A-410
K9 G9
G9 E9
M13 K13
G13 E13
5'-7"4"6'-4"4"6'-3"
18'-10"
/2
/2
1'-6"
6'-3"
3'-0 3/4 "3'-1"5'-1 1/2 "
5'-10 1/2 "
/2
3'-0"
/2
2'-0"
2'-0"
A N
S
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W
F
B
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
B
G O
R U
P
L E
V E
L
B
A S
IC
P L
A N
S
E L
E V
A T
IO
N
.0
E N
L A
R G
E D
T O
IL
E
T R
O O
M
A-402
M
B
IE
G E
R T
B
G O
R
A
-4
.d
B
IE
G E
P
D
:4
:4
A M
/2
/2
F R
A
-4
.d g n
PLUMBING CHASE
EXTEND EXISTING
9.
10.
11.
13.
14.
21.
22.
22.
24.
TOILET
WOMENS
LOBBY
ELEVATOR
RESTROOM
WOMENS
9.
16.
2.
17.
15.
16.
6.
5.
15.
17.
4.
14.
15.
17.
16.
8.
10.
9.
7.
11.7.13.12.
13.
16.
15.
10.
8.
18.
22.
7.
24.
21.
4.
5.
15.
22.
6.
24.
21.
22.
2.
10.
9.
13.
11.
22. 19. 20.
18. 22. 17.18.
15.
6.
5.
7.
21.24.22.
4.
5.
17.
17.
18.
21.
KEYED NOTES - REMOVAL AND DEMOLITION KEYED NOTES - NEW CONSTRUCTION
LOBBY
ELEVATOR
RESTROOM
WOMENS
TOILET
WOMENS
TOILET
MENS
TOILET
MENS
PRESSED STEEL DOOR FRAME, AND DOOR HARDWARE.
REMOVE AND SALVAGE FOR THE GOVERNMENT EXISTING HOLLOW METAL DOOR,22.
REMOVE AND SCRAP EXISTING CEILING MOUNTED ACCESS DOOR.21.
REMOVE AND SCRAP EXISTING CEILING MOUNTED LIGHT FIXURE 20.
EXISTING WALL HEATER TO REMAIN19.
AT CEILING AND ASSOCIATED TOILET PARTITION SUPPORT STRUCTURE.
REMOVE AND SCRAP EXISTING SUSPENDED PLASTER WALL/BULKHEAD ASSEMBLY 18.
ASSEMBLY AS REQUIRED FOR ACCESS TO ABOVE CEILING WORK.
REMOVE AND SCRAP PORTIONS OF EXISTING SUSPENDED PLASTER CEILING 17.
BED TO THE STRUCTURAL WALL TO RECEIVE NEW WALL TILE.
REMOVE AND SCRAP EXISTING CERAMIC WALL TILE, COVED BASE, AND SETTING 16.
STRUCTURAL FLOOR SLAB TO RECEIVE NEW FLOOR TILE.
REMOVE AND SCRAP EXISTING CERAMIC FLOOR TILE AND SETTING BED TO THE 15.
EXISTING SUPPLY AND WASTE LINES.
REMOVE AND SALVAGE FOR THE GOVERNMENT EXISTING MOP SINK. CAP14.
REMOVE AND SCRAP EXISTING TOILET PARTITION AND URINAL SCREEN.13.
REMOVE AND SCRAP FOR THE GOVERNMENT EXISTING URINAL.12.
REMOVE AND SCRAP FOR THE GOVERNMENT EXISTING LAVATORY.11.
REMOVE AND SCRAP FOR THE GOVERNMENT EXISTING TOILET FIXTURE.10.
REMOVE AND SCRAP EXISTING GRAB BARS.9.
REMOVE AND SCRAP EXISTING TOILET TISSUE DISPENSER.8.
REMOVE AND SCRAP EXISTING GLASS SHELF.7.
REMOVE AND SCRAP EXISTING LAVATORY AND VANITY UNIT.6.
REMOVE AND SCRAP EXISTING MIRROR.5.
REMOVE AND SCRAP EXISTING SOAP DISPENSER.4.
REMOVE AND SCRAP EXISTING PAPER TOWEL DISPENSER.3.
REMOVE EXISTING WALL.2.
NOT USED.1.
ELEVATION - TYP.
SUSPENDED ACOUSTICAL TILE CEILING. SEE SHEET A-600 FOR CEILING 24.
POSSIBLE DAMAGE FROM REMOVAL WORK - TYP.
REPAIR EXISTING PLASTER WALLS TO MATCH EXISTING DUE TO 23.
NEW CERAMIC TILE WAINSCOT AND BASE.22.
NEW CERAMIC TILE FLOOR ON SETTING BED.21.
2-1/2" STEEL STUD FURRING TO CONCEAL EXISTING STEEL COLUMN. 20.
NEW TOILET PARTITION.19.
URINAL.18.
NEW URINAL SCREEN.17.
NOT USED.16.
NEW SOLID SURFACE MATERIAL COUNTERTOP WITH LAVATORY.15.
NEW SANITARY NAPKIN DISPOSER (SND).14.
NEW TOILET TISSUE DISPENSER (TTD).13.
NOT USED.12.
NEW GRAB BAR 2.11.
NEW GRAB BAR 1.10.
NEW TOILET.9.
EXISTING WALL HEATER.8.
NEW PAPER TOWEL DISPENSER/WASTE RECEPTACLE (PTD/WR).7.
NEW MIRROR (MG).6.
NEW SOAP DISPENSER (SD).5.
NEW COUNTERTOP WITH LAVATORY AND BASE CABINETS.4.
NOT USED.3.
AND GYPSUM WALLBOARD, PLASTER, AND CERAMIC TILE FINISH.
EXTEND EXISTING PLUMBING CHASE WITH STEEL STUD 2.
NOT USED.1.
CABINET TO REMAIN
EXISTING FIRE HOSE
TO REMAIN
HOSE CABINET
EXISTING FIRE
2.
16.
16.2. CLOSET
JANITORS
2.
5.
16.
16.
16.
16.
5.
5.
17.
22.
22.
22.
7.
19.
8.
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E
SCALE: ¼''= 1'-0"
0 4'4' 2'
NORTH
G1 DEMOLITION FLOOR PLAN - ELEV. 1291.0 - LEVEL 2 NEW FLOOR PLAN - ELEV. 1291.0 - LEVEL 2
G11
A M
G E
N E
R A
L R
E V
IS
IO
N S
-2
-2
4A 456 4A 456
A N
S
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W
F
B
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
B
G O
R
IL
E
T R
O O
M
N U
R S
IN
G
M O
T H
E R
S R
O O
M E
L E
V A
T
IO
N S
A-411
M
B
IE
G E
R T
B
G O
R
A
-4 .d
B
IE
G E
P
D
:4
:1
A M
/2
/2
F R
A
-4 .d g n
ELEV. 1273.0
FIN FLOOR
NORTH ELEVATION
NURSING MOTHERS ROOM
EAST ELEVATION
NURSING MOTHERS ROOM
SOUTH ELEVATION
NURSING MOTHERS ROOM
WEST ELEVATION
NURSING MOTHER ROOM
ELEV. 1273.0
FIN FLOOR
ELEV. 1273.0
FIN FLOOR
ELEV. 1273.0
FIN FLOOR
ELEV. 1273.0
FIN FLOOR
DOOR
REINSTALLED
EXISTING
AND FRAME
REINSTALLED EXIST. ALUM. DOOR
8" MIN BEARING EA. SIDE FOR
UNITS FOR NEW LINTEL W/
PLASTER AND STRUCT. CLAY
REMOVE AND SCRAP EXISTING
CERAMIC TILE
EXISTING WALL
REMOVE AND SCRAP
DEMO - ENTRY CORRIDOR SOUTH ELEVATION
ELEV. 1273.0
FIN FLOOR
ASSEMBLY
DOOR
REINSTALLED
EXISTING
FOR REINSTALLATION
EXISTING DOOR ASSEMBLY
CAREFULLY REMOVE
FOR REINSTALLATION
EXISTING FLOOR TILE
CAREFULLY REMOVE
ASSEMBLY.
OPENING AND
SUPPORT NEW DOOR
AND PLASTER TO
NEW LINTEL BEYOND
CERAMIC TILE
EXISTING WALL
REMOVE AND SCRAP
NURSING MOTHERS ROOM
NEW DOOR OPENING TO
WALL IN ENTRY CORRIDOR
NEW PAINT OF THE ENTIRE
FRIDGE
MINI
NEW
TOP AND SINK
NEW COUNTER
PAINT
WITH NEW
NEW WALL,
PAINT
WITH NEW
NEW WALL,
CABINETRY
UNDERCOUNTER
DOOR
FIT EXISTING
EXISTING WALL TO
CUT INTO THE
OPENING TO BE
NEW DOOR
IN THE SAME PLANE AS EXISTING.
SMOOTH UNIFORM APPEARANCE
NEW FINISHED WALL TO HAVE A
BE FLUSH WITH EXISTING PLASTER.
NEW PLASTER OR GYPSUM BOARD TO
WALL TILE.
REPLACE THE REMOVED CERAMIC
PLASTER OR GYPSUM BOARD TO
PATCH EXISTING, AND INSTALL NEW
CERAMIC TILE
EXISTING WALL
REMOVE AND SCRAP
NEW PAINT FOR ENTIRE WALL
ELEV. 1273.0
FIN FLOOR
ELEV. 1273.0
FIN FLOOR
CERAMIC TILE
EXISTING WALL
REMOVE AND SCRAP
ELEV. 1273.0
FIN FLOOR
CERAMIC TILE
EXISTING WALL
REMOVE AND SCRAP
ELEV. 1273.0
FIN FLOOR
NEW PAINT FOR ENTIRE WALL
ELEV. 1273.0
FIN FLOOR
NEW PAINT FOR ENTIRE WALL
ELEV. 1273.0
FIN FLOOR
K2
ENTRY CORRIDOR SOUTH ELEVATION
K11
DEMO - ENTRY CORRIDOR NORTH ELEVATION
G2
ENTRY CORRIDOR NORTH ELEVATION
G11
E2
EAST ELEVATION
DEMO - ENTRY CORRIDOR
E5
WEST ELEVATION
DEMO - ENTRY CORRIDOR
E11
EAST ELEVATION
ENTRY CORRIDOR
E16
WEST ELEVATION
ENTRY CORRIDOR
B2 B6 B10 B14
MGSD
NEW STAINLESS STEEL BASE
FOR REUSE.
SALVAGE DOOR
REMOVE AND
ASSEMBLY.
OPENING AND
SUPPORT NEW DOOR
AND PLASTER TO
NEW LINTEL BEYOND
ASSEMBLY.
OPENING AND
SUPPORT NEW DOOR
AND PLASTER TO
NEW LINTEL BEYOND
IN THE SAME PLANE AS EXISTING.
SMOOTH UNIFORM APPEARANCE
NEW FINISHED WALL TO HAVE A
BE FLUSH WITH EXISTING PLASTER.
NEW PLASTER OR GYPSUM BOARD TO
WALL TILE.
REPLACE THE REMOVED CERAMIC
PLASTER OR GYPSUM BOARD TO
PATCH EXISTING, AND INSTALL NEW
IN THE SAME PLANE AS EXISTING.
SMOOTH UNIFORM APPEARANCE
NEW FINISHED WALL TO HAVE A
BE FLUSH WITH EXISTING PLASTER.
NEW PLASTER OR GYPSUM BOARD TO
WALL TILE.
REPLACE THE REMOVED CERAMIC
PLASTER OR GYPSUM BOARD TO
PATCH EXISTING, AND INSTALL NEW
IN THE SAME PLANE AS EXISTING.
SMOOTH UNIFORM APPEARANCE
NEW FINISHED WALL TO HAVE A
BE FLUSH WITH EXISTING PLASTER.
NEW PLASTER OR GYPSUM BOARD TO
WALL TILE.
REPLACE THE REMOVED CERAMIC
PLASTER OR GYPSUM BOARD TO
PATCH EXISTING, AND INSTALL NEW
IN THE SAME PLANE AS EXISTING.
SMOOTH UNIFORM APPEARANCE
NEW FINISHED WALL TO HAVE A
BE FLUSH WITH EXISTING PLASTER.
NEW PLASTER OR GYPSUM BOARD TO
WALL TILE.
REPLACE THE REMOVED CERAMIC
PLASTER OR GYPSUM BOARD TO
PATCH EXISTING, AND INSTALL NEW
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E
NTS NTS
NTS
NTS NTS
NTS
NTS
NTS NTS
NTSNTS
NTS
A M
G E
N E
R A
L R
E V
IS
IO
N S
-1
-2
N
S
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W
F
B
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
B
G O
R
W
L L
T Y
P E
S
A-500
M
B
IE
G E
R T
B
G O
R
A
-5
.d
B
IE
G E
P
D
:5
:4
A M
/2
/2
F R
A
-5
.d g n
ON A-600)
FINISH SCHEDULE
FINISH FLOOR (SEE
OCCURS (SEE SCHEDULE)
FINISH CEILING WHERE
EXISTING STRUCTURE
UNDERSIDE OF
MTL. STUD PARTITION
OR FIRE SAFING
COMPRESSIBLE FILLER
NON COMBUSTIBLE
WALLS
5/8" TYPE "X" GWB @ FR
WHERE REQUIRED
DEFLECTION TRACK
FABRICATED
FACTORY OR FIELD
METHOD W-245
(WAINSCOT) WALL TCA
CERAMIC TILE
RESILIENT BASE
UNITS
CEMENTITIOUS BACKER
FRAMING AT 1'-4" O.C.
20 GA 6" MTL. STUD
CERAMIC TILE BASE
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E
G3
WALL TYPE
A M
G E
N E
R A
L R
E V
IS
IO
N S
-1
-2
SCHED
SEE
S C
H E
D U
L E
3'-4"
SCHED
SEE
A N
S
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W
F
B
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
B
G O
R
O M
F
IN
IS
H
A N
D D
O O
R S
C H
E D
U L
E S
A-600
M
B
IE
G E
R T
B
G O
R
A
-6
.d
B
IE
G E
P
D
:0
:0
P
M
/2 /2
F R
A
-6
.d g n
1 2 3 4 65
SOUTHNORTH
CEILINGWALLS
FLOOR BASE
RM
NO
ROOM NAME
7 8 1 2 3 4 5 6 1 2 3 4 5 6 7 8
WAINSCOT
MAT. HGT.
1 2 3 1 2 3 4 5 6 7 8 1 2 3
WAINSCOT
MAT. HGT.
REMARKS
1 2 3 4 5 6 7 8 1 2 3
WAINSCOT
MAT. HGT.
1 2 3 4 5 6 7 8 1 2 3
WAINSCOT
MAT. HGT.
EAST WEST
1 2 3 4 5
HGT.MAT. TYPE
C O
N C
R E
T E
M A
S O
N R
Y U
N I T
S
N E
W A
C O
U S
T I C
A L
D R
O P
T I L
E
S U
S P
E N
D E
D
R
IG
ID
S R
(SEE NOTES)
9'-0"
E
S I L
I E
S I L
I E
N T
T I L
E
C O
N C
R E
T E
M A
S O
N R
Y U
N I T
S
C O
N C
R E
T E
M A
S O
N R
Y U
N I T
S
C O
N C
R E
T E
M A
S O
N R
Y U
N I
T A
L D
E C
K I N
G E
X P
S
T R
G Y
P S
U M
B O
A R
D
C A
R P
E T
C O
N C
R E
T E
E
X I S
T I N
G
C E
R A
M I C
T I L
E
E X
I S
T I N
G
P L
A S
T E
R E
X I S
T I N
G
S T
R U
C T
C L
A Y
U N
I T
S E
X I S
T
C O
N C
R E
T E
E
X I S
T
ROOM MATERIAL AND FINISH SCHEDULE
C O
N C
R E
T E
E
X I S
T
C O
N C
R E
T E
E
X I S
T
C O
N C
R E
T E
E
X I S
T
S T
R U
C T
C L
A Y
U N
I T
S E
X I S
T
S T
R U
C T
C L
A Y
U N
I T
S E
X I S
T
S T
R U
C T
C L
A Y
U N
I T
S E
X I S
T
C E
R .T
I L
E N
E W
C E
R .T
I L
E N
E W
P L
A S
T E
R E
X I S
T I N
G
P L
A S
T E
R E
X I S
T I N
G
P L
A S
T E
R E
X I S
T I N
G
N O
N E
R E
Q U
I R
E D
E
X I S
T
S T
A I N
L E
S S
S T
P A
N E
L
S T
A I N
L E
S S
S T
P A
N E
L
S T
A I N
L E
S S
S T
P A
N E
L
S T
A I N
L E
S S
S T
P A
N E
L
P L
A S
T E
R E
X I S
T
1.
1.
M E
T A
L P
A N
E L
S E
L E
V A
T O
R
DOOR SCHEDULE
DR
NO.
DOOR LOCATION DOOR SIZE
DOOR FRAME DETAILS FIRE LABEL
& RATING
HDWR REMARKS
(SEE NOTES BELOW)SILLJAMBHEADMATTYPEMAT.TYPE SET
L
L A
L HM PS
L HM A PS
L HM PS
L A
H1/A-730 A1/A-730 B10/A-730
H1/A-730 A1/A-730 B10/A-730
NO SCALE
A F
S E
E S
C H
E D
U L
E
FRAME TYPES
NO SCALE
DOOR TYPES
3'-0 X 7'-0"
3'-0 X 7'-0"
3'-0 X 7'-0"
3'-0 X 7'-0"
3'-0 X 7'-0"
3'-0 X 7'-0"
3'-0 X 7'-0"
ELEV. LOBBY TO ENTRY CORRIDOR
101 NURSING MOTHERS ROOM
WOMENS TOILET102
103 ENTRY CORRIDOR
104 MENS TOILET
MENS TOILET
WOMENS RESTROOM
WOMENS TOILET
C E
R A
M I C
T I L
E
N E
W
C E
R A
M I C
T I L
E N
E W
G Y
P S
U M
B O
A R
D /P
L A
S T
E R
N
E W
G Y
P S
U M
B O
A R
D /P
L A
S T
E R
N
E W
G Y
P S
U M
B O
A R
D /P
L A
S T
E R
N
E W
G Y
P S
U M
B O
A R
D /P
L A
S T
E R
N
E W
4'-9"
9'-0"
9'-0"
1., 2.
1., 2.
1.
1.
LOBBY TO WOMENS TOILET ALUM A ALUM
ENTRY TO NURSING MOTHERS ROOM ALUM ALUM
ALUM
ENTRY HALL TO MENS TOILET ALUM ALUM
ELEV LOBBY TO MENS TOILET A
ELEV LOBBY TO WOMENS RESTRM.
AWOMENS RESTRM TO TOILET
L
S E
E S
C H
E D
U L
E
1,4,10
1,4, 7
A
1.
1., 3.
1.
C E
R .T
I L
E N
E W
C E
R .T
I L
E N
W
ELEVATOR LOBBY-ELEV. 1273.0
ELEVATOR LOBBY-ELEV. 1291.0
4, 9
WAS REMOVED.
BY THE MANUFACTURER AT THE HEAD AND JAMBS TO FINISH THE OPENING WHERE DOOR
STEEL CORNER GUARDS OR BENT PLATES SECURED WITH FASTENERS AS RECOMMENDED
DOOR ASSEMBLY TO MATCH EXISTING. PROVIDE CONT. +/- 7 5/8" X 2" X 0.0625" STAINLESS
3. FINISH AND REPAIR WALL ENDS AND RETURN AFTER REMOVAL OF EXISTING
REINSTALLED EXISTING MIRROR.
2. SEE A-410 FOR THE PATTERN AND HEIGHT OF THE CERAMIC TILE WAINSCOT AT
REPRESENTATIVE COLOR APPROVAL.
FINSISHES AND COLORS WHERE APPLICABLE. COORDINATE WITH CONSTRUCTION
1. PAINT ALL EXISTING PLASTER WALLS, CEILINGS AND FINISHES TO MATCH EXISTING
ROOM FINISH SCHEDULE REMARKS NOTES:
REMOVED DOOR ASSEMBLY FROM THE EXISTING MENS TOILET ROOM 104.
10. DOOR ASSEMBLY TO BE INSTALLED FOR THE NEW WOMENS TOILET ROOM IS THE EXISTING
REMOVED DOOR ASSEMBLY FROM THE ENTRANCE TO THE EXISTING WOMENS TOILET ROOM 102.
9. DOOR ASSEMBLY TO BE INSTALLED FOR THE NEW NURSING MOTHERS ROOM IS THE EXISTING
8. NOT USED
ASSEMBLY FROM THE ENTRANCE TO EXISTING ENTRY CORRIDOR 103.
7. DOOR ASSEMBLY TO BE INSTALLED FOR NEW MENS TOILET 104 IS THE EXISTING REMOVED DOOR
. NOT USED.6
EXISTING H.M. DOORS AND FRAMES TO REMAIN IN PLACE. PAINT ALL TO MATCH EXISTING. 5.
REUSE ALL EXISTING DOOR HARDWARE - TYP.4.
EXISTING REINSTALLED ALUMINUM DOOR FRAME .3.
ROOM.
EXISTING DOOR AND FRAME ASSEMBLY TO REMOVED AND REINSTALLED IN NEW MENS TOILET 2.
REINSTALLED AND THOSE TO REMAIN IN PLACE.
AND PLINTH. GREAT CARE SHALL BE TAKEN TO NOT DAMAGE EXISTING CERAMIC TILES TO BE
EXISTING REINSTALLED ALUMINUM DOOR, FRAME, ROUGH BUCK, EXPANSION WING CASING, 1.
DOOR SCHEDULE REMARKS NOTES:
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4'-9"
4,5
4,5
C E
R .T
I L
E E
X I S
T I N
G
C E
R .T
I L
E E
X I S
T I N
G
C E
R .T
I L
E E
X I S
T I N
G
C E
R .T
I L
E E
X I S
T I N
G
OF EXISTING AND NEW ROOMS.
SEE DRAWINGS A-400 AND A-402 FOR ROOM NAMES AND NUMBERS 1.
GENERAL NOTES:
4,5
H1/A-730 - SIM A1/A-730 - SIM B10/A-730 - SIM
H1/A-730 - SIM A1/A-730 - SIM B10/A-730 - SIM
H1/A-730 - SIM A1/A-730 - SIM B10/A-730 - SIM
H8 & H12/A-730 SIM E8 & E12/A-730-SIM
H1/A-730 A1/A-730 B10/A-730
B10/A-730 - SIM
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E
A M
G E
N E
R A
L R
E V
IS
IO
N S
-1
-2
S
H A
B
IL
IT
A
T
IO
N
P O
W E
R H
O U
S E
R E
S T
R O
O M
F O
R T
R A
N D
A L
L D
A M
S
O U
T H
D A
K O
T A
W
F
B
/1
/2
A H
A
N E
C A
P
IT
O L
A V
E
O M
A H
A D
IS
T
R
E
N U
M B
E R
B
G O
R
O R
D E
T A
IL
S
A-730
M
B
IE
G E
R T
B
G O
R
A
-7
.d
B
IE
G E
P
D
:3
:1
P
M
/2 /2
F R
A
-7
.d g n
EXISTING PLASTER FINISH
GROUT FULL
EXISTING COURSING)
6" CMU (MATCH
TO MATCH EXISTING
NEW PLASTER FINISH
SHIM AS REQUIRED
BACKER ROD EA. SIDE
CONT. SEALANT AND
EXISTING PLASTER FINISH
GROUT FULL
(MATCH EXISTING COURSING)
2" CMU SOAP BLOCK
TO MATCH EXISTING
NEW PLASTER FINISH
FULL W/ GROUT
CORES UNDER BEARING
OF OPENING - FILL MASONRY
BEAR 8" MIN EA SIDE
2" X 2 1/2" X 3/8" LINTEL
STEEL ANGLES -
DOUBLE BACK TO BACK
BACKER ROD EA. SIDE
CONT. SEALANT AND
FRAME SOLID
ASSEMBLY - GROUT
ALUMINUM DOOR FRAME
EXISTING REINSTALLED
ALUMINUM DOOR
EXISTING REINSTALLED
FOR REMOVAL AND REINSTALL
CARE SHALL BE TAKEN
CERAMIC TILE. GREAT
EXIST. REINSTALLED
(4 PER JAMB MIN.)
JAMB ANCHORS -
FRAME SOLID
ASSEMBLY - GROUT
ALUMINUM DOOR FRAME
EXISTING REINSTALLED
ALUMINUM DOOR
EXISTING REINSTALLED
AND SPALLING.
UNITS TO PREVENT DAMAGE
DRILLING INTO EXISTING
REMOVING, CUTTING OR
SHALL BE TAKEN WHEN
CLAY UNITS. GREAT CARE
EXISTING STRUCTURAL
AND SPALLING.
UNITS TO PREVENT DAMAGE
DRILLING INTO EXISTING
REMOVING, CUTTING OR
SHALL BE TAKEN WHEN
CLAY UNITS. GREAT CARE
EXISTING STRUCTURAL
EXISTING PLASTER FINISH
ELEVATOR LOBBY
103 SIDE - RETAIN AT
AT THE ENTRY CORRIDOR
WAINSCOT BELOW. REMOVE
EXISTING CERAMIC TILE
BACKER ROD EA. SIDE
CONT. SEALANT AND
REMOVE AND SCRAP
DURING REMOVAL
AS INDICATED- DO NOT DAMAGE
ASSEMBLY - REMOVE AND REINSTALL
EXISTING ALUMINUM DOOR FRAME
REMOVAL
- DO NOT DAMAGE DURING
REINSTALL WHERE INDICATED
ASSEMBLY - REMOVE AND
EXISTING ALUMINUM DOOR
AND SPALLING.
UNITS TO PREVENT DAMAGE
DRILLING INTO EXISTING
REMOVING, CUTTING OR
SHALL BE TAKEN WHEN
CLAY UNITS. GREAT CARE
EXISTING STRUCTURAL
ELEVATOR LOBBY
103 SIDE - RETAIN AT
AT THE ENTRY CORRIDOR
WAINSCOT. REMOVE
EXISTING CERAMIC TILE
BACKER ROD EA. SIDE
CONT. SEALANT AND
REMOVE AND SCRAP
DURING REMOVAL
AS INDICATED- DO NOT DAMAGE
ASSEMBLY - REMOVE AND REINSTALL
EXISTING ALUMINUM DOOR FRAME
REMOVAL
- DO NOT DAMAGE DURING
REINSTALL WHERE INDICATED
ASSEMBLY - REMOVE AND
EXISTING ALUMINUM DOOR
AND SPALLING.
UNITS TO PREVENT DAMAGE
DRILLING INTO EXISTING
REMOVING, CUTTING OR
SHALL BE TAKEN WHEN
CLAY UNITS. GREAT CARE
EXISTING STRUCTURAL
EXISTING PLASTER FINISH
- RETAIN AT ELEVATOR LOBBY
ENTRY CORRIDOR 103 SIDE
DETAIL). REMOVE AT THE
WAINSCOT BELOW (AT JAMB
EXISTING CERAMIC TILE
AND SPALLING.
UNITS TO PREVENT DAMAGE
DRILLING INTO EXISTING
REMOVING, CUTTING OR
SHALL BE TAKEN WHEN
CLAY UNITS. GREAT CARE
EXISTING STRUCTURAL
AT THE AT ELEVATOR LOBBY
WAINSCOT TO REMAIN
EXISTING CERAMIC TILE
AND SPALLING.
UNITS TO PREVENT DAMAGE
DRILLING INTO EXISTING
REMOVING, CUTTING OR
SHALL BE TAKEN WHEN
CLAY UNITS. GREAT CARE
EXISTING STRUCTURAL
APPEARANCE
SEALANT TO PROVIDE A FINSIHED
CONTRCUTION TO REMAIN WITH
WHERE MEETING EXISTNG
MANUFACUTER. FINISH ALL EDGES
AS RECOMMENDED BY THE
SUPPORTING CONSTRUCTION
SECURED WITH FASTENERS TO
AT JAMBS AND HEAD
CLOSURE +/- 7 5/8" X 2" X 0.0625"
CORNER GUARD OR BENT PLATE
NEW CONT. STAINLESS STEEL
APPEARANCE
SEALANT TO PROVIDE A FINSIHED
CONTRCUTION TO REMAIN WITH
WHERE MEETING EXISTNG
MANUFACUTER. FINISH ALL EDGES
AS RECOMMENDED BY THE
SUPPORTING CONSTRUCTION
SECURED WITH FASTENERS TO
AT JAMBS AND HEAD
CLOSURE +/- 7 5/8" X 2" X 0.0625"
CORNER GUARD OR BENT PLATE
NEW CONT. STAINLESS STEEL
SAME PLANE ON CORRIDOR 103 SIDE
FURRING AND TO REMAIN IN THE
OF THE EXISTING PLASTER
STRIPS TO MATCH THE DEPTH
WALLBOARD ON FURRING CHANNELS/
PLASTER DEPTH OR GYPSUM
METAL LATH TO MATCH EXISTING
NEW CEMENT PLASTER ON
CONC. FLOOR SLAB
SETTING BED, ON EXIST
NEW CERAMIC TILE,
SET IN SEALANT
THRESHOLD, & ASSEMBLY
ALUMINUM DOOR, FRAME
EXISTING REINSTALLED
SEALANT JOINT
TRANSITION STRIP AND
CONC. FLOOR SLAB W/
SETTING BED, ON EXIST
NEW CERAMIC TILE,
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
A
B
C
D
E
F
G
H
J
K
L
M
N
P
S U
B M
IT
T
E D
B Y
C H
E C
K E
D B
Y
D R
A W
N B
Y
D E
S
IG
N E
D B
Y
C O
N T
R A
C T
N O
S O
L
IC
IT
A
T
IO
N N
O
IS
S
U E
D A
T E
S I Z
E
M A
R K
D E
S C
R
IP
T
IO
N D
A T
E
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A D
V E
R T
IS
E
M E
N T
F
IL
E N
A M
E :H1
A1
B10
DOOR SILL DETAIL
DOOR JAMB DETAIL
DOOR HEAD DETAIL
NTS
NTS
NTS
H8
PLASTER WALL HEAD (JAMB IS SIMILAR)
EXISTING DOOR DEMO DETAIL AT
NTS
H12
NTS
PLASTER WALL HEAD (JAMB IS SIMILAR)
NEW DETAIL AT EXISTING DOOR OPENING AT
CERAMIC TILE WAINSCOT AND DOOR JAMB
EXISTING DOOR DEMO DETAIL AT
NTS
E8 E12
CERAMIC TILE WAINSCOT AND DOOR JAMB
NEW DETAIL AT EXISTING DOOR OPENING DOOR AT
NTS
A M
G E
N E
R A
L R
E V
IS
IO
N S
-1
-2
| FR00107A-160 |
| FR00107A-161 |
| FR00107A-400 |
| FR00107A-402 |
| FR00107A-411 |
| FR00107A-500 |
| FR00107A-600 |
| FR00107A-730 |