This document provides details on a federal contract solicitation for replacement of overhead conductors and associated equipment at the Oahe Powerhouse in Pierre, South Dakota. The U.S. Army Corps of Engineers, Omaha District will issue solicitation number W9128F22B0004 for the Oahe Powerhouse Line 1 project, with responses due on or around March 21, 2022. The estimated value of construction is between $200,000 and $500,000. The work involves replacing the entire 115kV line from the generator step-up transformer outside the powerhouse to the switchyard, including removing existing conductors, insulators, connectors and hardware, and installing new overhead conductors and equipment. The primary NAICS code is 237130 for power and communication line and related structure construction. Offerors should register in the System for Award Management and check for annual representations and certifications requirements. Additional details on the site visit and point of contact for questions are provided.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Bid Abstract_W9128F22B0004 OA Powerhouse Line 1.pdf | ||
| W9128F22B0004.pdf | ||
| w9128f22b0004 powerhouse line 1 oahe specs.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:50:53 AM 2/11/2022
...\30500 - Construction E&D\OAA1\30DA0 - Plans & Specs\CAD_BIM\_Sheets\COVER & I
SOLICITATION NO.:
CONTRACT NO.:
ISSUE DATE:
of Engineers
US Army Corps
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R
M
A H
A
N E
F
IL
E N
A M
E
Omaha District
F
IL
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A
G -0
.d g n
A H
A D
IS
T R
IC
T
OAHE DAM, SOUTH DAKOTA
POWERHOUSE LINE 1
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
C O
V E
R I
N D
E X
A N
S I
D
G-001
M
H O
F F
M A
N
M
H O
F F
M A
N
M
H O
F F
M A
N
M
H O
F F
M A
N
W
F
B
W9128F22B0004
ADVERTISEMENT
F E
B R
U A
R Y
FEBRUARY 2022
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg10:41:46 AM 2/7/2022
...\30500 - Construction E&D\OAA1\30DA0 - Plans & Specs\CAD_BIM\_Sheets\ABBREVIAT
A H
A
N E
F
IL
E N
A M
E
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
C
A P
IT
O L A
V E
F
IL
E N
U M
B E
R
O A
A
G -0
.d g n
ABBREVIATIONS
FRAMINGFRMG
FORGEDFRG
FRAMEFR
FIRE RESISTANT FR
FEET PER MINUTEFPM
FIREPROOFFP
FIRE PARTITIONFP
FACE OF STUDFOS
FACE OF MASONRYFOM
FACE OF FINISHFOF
FACE OF CONCRETEFOC
FENCEFN
FLUORESCENTFLUOR
FLOOR PLATEFLR PL
FLOORINGFLG
FLEXIBLEFLEX
FLOORFLR
FLASHINGFLASH
FLUSH JOINTFJT
FIXTUREFIXT
FINISH FLOORFIN FLR
FINISHFIN
FIGUREFIG
FLAT HEAD WOOD SCREWFHWS
FIRE HOSE STATIONFHS
FIRE HOSE RACKFHR
FLAT HEAD MACHINE SCREWFHMS
FIRE HOSE CABINETFHC
FLAT HEADFH
FIRE HYDRANTFH
FIBERGLASSFGL
FACTORY FINISHFF
FIRE EXTINGUISHER CABINETFEC
FIRE EXTINGUISHER BRACKETFEB
FIRE EXTINGUISHERFE
FOUNDATIONFDTN
FIRE DAMPERFDMPR
FLOOR DRAINFD
FAN COIL UNITFCU
FLOOR CLEANOUTFCO
FLOOR CONSTRUCTION JOINTFCJ
FACINGFCG
FACE BRICKFC BRK
FOOT CANDLEFC
FIRE BRICKF BRK
FRESH AIR INTAKEFAI
FIRE APPARATUS CLOSETFAC
FRESH AIRFA
FIRE ALARMFA
FAHRENHEITF
EXTERIOREXT
EXPANSION BOLTEXP BT
EXPOSEDEXP
EXPANSIONEXP
EXISTINGEXST
EXHAUST AIREXH A
EXHAUSTEXH
EXCAVATEEXC
ENTERING WATER TEMPERATUREEWT
ELECTRIC WATER COOLEREWC
ESTIMATE(D)EST
ESCALATORESCAL
EQUIPMENTEQUIP
EQUALEQ
EPOXY COATINGEPY
EXPLOSION PROOFEPRF
ELECTRICAL PANELBOARDEP
ENTRANCE, ENTERINGENTR
ENCLOSE(URE)ENCL
EMERGENCYEMER
ESTIMATED MAXIMUM DEMANDEMD
EXPANDED METAL EM
ELECTRICELEC
ELEVATION - GRADE OR BUILDINGEL
EXPANSION JOINTEJ
EACH FACEEF
ENTERING AIR TEMPERATUREEAT
EACHEA
EASTE
DIRECT EXPANSIONDX
DUMBWAITERDWTR
DRAWERDWR
DOWELSDWLS
DRAWINGDWG
DOVETAIL DVTL
DRAIN TILEDT
DOWNSPOUTDS
DOUBLE STRENGTH (GLASS)DS
DOOR CLOSERDR CL
DRAINBOARDDRB
DRAINDR
DOORDR
DOWNDN
DEMOUNTABLEDMT
DAMPERDMPR
DAMPPROOFINGDMPF
DEAD LOADDL
DIVISIONDIV
DISTRIBUTION PANELDISTR PNL
DISPENSERDISP
DISCONNECTDISC
DIMENSIONDIM
DIAGONALDIAG
DIAMETERDIA
DUCT HEATERDH
DOUBLE HUNGDH
DRINKING FOUNTAINDF
DETAILDET
DEPARTMENTDEPT
DEPRESSIONDEPR
DEMOLITIONDEMO
DEGREEDEG
DUMMY CONTROL JOINTDCJT
DOWELED CONTROL JOINTDCJ
DOUBLE ACTING DOORDBL ACT DR
DOUBLEDBL
DRY BULBDB
DATUMDAT
PENNY (AS IN NAIL - 10D)d
CYLINDERCYL
COLD WATERCW
CONDUCTIVE VINYL HOMOGENEOUS (SHEET TYPE)CVH
CEILING VENTCV
CUBIC YARDSCU YD
CABINET UNIT HEATERCUH
CUBIC FEETCU FT
COPPERCu
CONDENSING UNITCU
CENTERCTR
CENTER TO CENTERC TO C
CURRENT TRANSFORMERCT
CERAMIC TILECT
CASEMENTCSMT
COUNTERSUNKCSK
CAST STONECS FRT FIRE-RETARDANT
FS FULL SIZE
FSTNR FASTEN(ER)
FT FEET
FTG FOOTING
FURG FURRING
FUT FUTURE
FW FIRE WATER
FWC FABRIC WALL COVERING
G NATURAL GAS
GA GAGE
GAL GALLON(S)
GALV GALVANIZED
GALV STL GALVANIZED STEEL
GB GRAB BAR
GC GENERAL CONTRACTOR
GEN GENERAL
GF GROUND FACE
GFCI GROUND FAULT CIRCUIT INTERRUPTER
GFE GOVERNMENT-FURNISHED EQUIPMENT
GFE/CI GOVERNMENT-FURNISHED EQUIPMENT CONTRACTOR INSTALLED
GI GALVANIZED IRON
GIP GALVANIZED IRON PIPE
GKT GASKET(ED)
GL GLASS
GL BLK GLASS BLOCK
GLF GLASS FIBER
GLZ GLAZING
GLZ CMU GLAZED CONCRETE MASONRY UNITS
G GROUND
GOVT GOVERNMENT
GPM GALLONS PER MINUTE
GPT GYPSUM TILE
GRAN GRANITE
GR LN GRADE LINE
GRTG GRATING
GST GLAZED STRUCTURAL TILE
GSU GLAZED STRUCTURAL UNITS
GT GROUT
GWT GLAZED WALL TILE
GYP GYPSUM
GYP BD GYPSUM BOARD
GYP PLAS GYPSUM PLASTER
HB HOSE BIBB
HC HOLLOW CORE
HCD HALON CONTAINMENT DAMPER
HCP HANDICAPPED
HD HEAD
HD HEAVY DUTY
HDBD HARDBOARD
HD JT HEAD JOINT
HDR HEADER
HDW HARDWARE
HDWD HARDWOOD
HES HIGH EARLY-STRENGTH CEMENT
HEX HEXAGON
HH HANDHOLE
HK HOOK(S)
HM HOLLOW METAL
HNDRL HANDRAIL
HORIZ HORIZONTAL
HP HIGH PRESSURE
HP HORSEPOWER
HPT HIGH POINT
HR HOUR
HS HIGH STRENGTH
HSGYP HIGH-STRENGTH GYPSUM PLASTER
HSKPG HOUSEKEEPING
HT HEIGHT
HTG HEATING
HTR HEATER
HVAC HEATING, VENTILATING AND AIR CONDITIONING
HYDR HYDRAULIC
Hz HERTZ
IC INTERCOM
ID INSIDE DIAMETER
IESNA ILLUMINATING ENGINEERING SOCIETY OF NORTH AMERICA
ILK INTERLOCK
IN INCH
INCIN INCINERATOR
INCL INCLUDED
INSF INSULATING FILL
INSUL INSULATION
INT INTERIOR
INTM INTERMEDIATE
INV INVERT
IP IRON PIPE
IPS IRON PIPE SIZE
I.P.S. INSIDE PIPE SIZE
JAN CLO JANITOR’S CLOSET
J-BOX JUNCTION BOX
JCT JUNCTION
JST JOIST
JT JOINT
KIP KILOPOUND (1000 POUNDS)
KIT KITCHEN
KOP KNOCKOUT PANEL
KPL KICKPLATE
kV KILOVOLTS kVA KILOVOLT AMPERES kVAR KILOVOLT AMPERES REACTIVE kW KILOWATT
KWY KEYWAY
LAB LABORATORY
LAD LADDER
LAM LAMINATE
LAT LEAVING AIR TEMPERATURE
LAU LAUNDRY
LAV LAVATORY
LB LAG BOLT
LB POUND
LBL LABEL
LBR LUMBER
LC LIGHT CONTROL
LD LOAD
LDG LOADING
LG LENGTH
LH LEFT HAND(ED)
LIN LINEAR
LKR LOCKER
LL LIVE LOAD
LLD LEAD-LINED DOOR
LM LUMEN
LMST LIMESTONE
LNTL LINTEL
LONG LONGITUDINAL
LP LIGHTPROOF
LPD LIGHTPROOF DOOR
LPL LIGHTPROOF LOUVER
LPT LOW POINT
LR LIVING ROOM
LS LAWN SPRINKLER
LT LIGHT
LT WT LIGHTWEIGHT
LTG LIGHTING
PRESTRESSED CONCRETEPS CONC
PRESSED STEELP.S.
PIPE SPACEPS
PRESSURE-REGULATING VALVEPRV
PROJECTPROJ
PARKINGPRKG
PREFORMEDPREFMD
PREFINISHEDPREFIN
PREFABRICATE(D)PREFAB
PAIRPR
PARTS PER MILLIONPPM
POLISHED PLATE GLASSPPGL
PORTABLEPORT
PORCELAINPORC
POLISHEDPOL
PAINT(ED)PT
PANELPNL
PLYWOODPLYWD
PLATE GLASSPL GL
PILINGPLG
POUNDS PER LINEAR FOOTPLF
PLUMBINGPLBG
PLATFORMPLAT
PLASTERPLAS
PLASTIC LAMINATEPLAM
PROPERTY LINEPL
PLATEPL
POST INDICATING VALVEPIV
PREFAB ISOLATION POWER UNITPIPU
POINT OF INTERSECTIONPI
PHARMACYPHAR
PHASEPH
PERIMETERPERIM
PERFORATE(D)PERF
PEDESTALPED
PAVEMENT DRAINPD
CEMENT PLASTER (PORTLAND)PCP
POUNDS PER CUBIC FOOTPCF
PRECAST CONCRETEPCC
PIECEPC
PUSH BUTTON STATIONPBS
PARTICLE BOARDPBD
PANIC BARPB
PARALLELPAR
PUBLIC ADDRESSPA
POLEP
OBSCURE WIRED GLASSOWGL
OUTSIDE SCREW AND YOKEOS & Y
OPERATIONSOPS
OPAQUEOPQ
OPPOSITEOPP
OPENINGOPNG
OPPOSITE HANDOPH
OVALHEAD WOOD SCREWOHWS
OVALHEAD MACHINE SCREWOHMS
OVERHEADOH
OBSCURE GLASSOGL
OFFICEOFC
OUTSIDE DIAMETEROD
ON CENTER EACH WAYOCEW
ON CENTEROC
OBSERVATION WINDOWOBW
OBSCUREOBSC
OUTSIDE AIROA
NOT TO SCALENTS
NOT REQUIREDN’’REQD
NOISE REDUCTION COEFFICIENTNRC
NOISE REDUCTIONNR
NOMINALNOM
NUMBERNO
NORMALLY OPENNO
NONMETALLICNM
NEOPRENE LATEXN.L.
NAILABLENL
NOT IN CONTRACTNIC
NICKELNi
NATIONAL FIRE PROTECTION ASSOCIATIONNFPA
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATIONNEMA
NATIONAL ELECTRICAL CODENEC
NORMALLY CLOSEDNC
NATURALNAT
NORTHN
MULLIONMULL
MOVABLEMVBL
METALMTL
METAL FURRINGMTFR
MOUNTEDMTD
MOUNTMT
METAL THRESHOLDMT
MACHINE SCREWSMS
METAL ROOF DECKINGMRD
MARBLE BASEMRB
MOP RECEPTORMR
MOVABLE PARTITIONMP
MOTORMOT
MODIFIEDMOD.
MODULARMOD
MASONRY OPENINGMO
MATERIAL NOT IN CONTRACT (INSTALLATION BY CONTRACTOR)MNIC
MILLIMETER(S)mm
MILLWORKMLWK
MOULDINGMLDG
MONOLITHICML
METAL LATHML
MISCELLANEOUSMISC
MIRRORMIRR
MINIMUMMIN
MALLEABLE IRONMI
MANHOLEMH
MATTE-GLAZED TILEMGT
MOTOR GENERATORMG
MANUFACTURERMFR
MANUFACTURINGMFG
METAL FLOOR DECKINGMFD
METAL EDGE STRIPMES
MEMBRANEMEMB
MEDIUMMED
MECHANICAL ROOMMECH RM
MECHANICALMECH
METAL DIVIDER STRIPMDS
METAL-CASED OPENINGMCO
MASONRY CONTROL JOINTMCJ
MEDICINE CABINETMC
MEMBERMBR
MACHINE BOLTSMB
MAXIMUMMAX
MATERIAL(S)MATL
MASONRYMAS
MACHINEMACH
MATCHED AND BEADEDM&B
METER(S)m
LEAVING WATER TEMPERATURELWT
LIGHTWEIGHT CONCRETELWC
LOUVERLVR
LIGHTNINGLTNG
THICK(NESS)THK
TRUSS HEADTH
TOGGLETGL
TONGUE AND GROOVET&G
TERMINALTERM
TERRAZZOTER
TEMPORARYTEMP
TEMPERATURETEMP
TELEPHONETEL
TERRA COTTATC
TOWEL BARTB
TANGENTTAN
TREADT
SYSTEMSYS
SYNTHETICSYNTH
SYMMETRICALSYMM
SWITCHBOARDSWBD
SWITCHSW
SHEET VINYL SV
SUSPENDEDSUSP
SUBFLOORSUB FL
STAIRWAYSTWY
STRUCTURALSTRUCT
STRINGERSTR
STATIC PRESSUREST PR
STORAGESTOR
STEELSTL
SEATINGSTG
STANDARDSTD
STATIONSTA
STAINLESS STEELSST
STANDING SEAM (ROOF)SS
SERVICE SINKSS
SHELF AND RODS&R
SQUARE HEADSQHD
SQUARESQ
SPEAKERSPKR
SPACE HEATERSPH
SPECIAL FINISHSP FIN
SOUNDPROOFSPF
SPECIFICATIONSPEC
SOUNDPROOF DOORSPD
SPECIALSPCL
SPACERSPC
SHUT OFF VALVESOV
SHEET METAL SCREWSSMS
SHEET METALSM
SLEEVESLV
SEALANTSLNT
SKYLIGHTSKLT
STEEL JOIST INSTITUTESJI
SIMILARSIM
SHELVINGSHV
SHEATHINGSHTHG
SHEETSHT
SHOULDERSHLDR
SHEET GLASSSG
STRUCTURAL FACING UNITSFU
STRUCTURAL FACING TILE UNITSFTU
SAFETY GLASSSFGL
SEQUENCESEQ
SECTIONSECT
STEEL DOOR INSTITUTESDI
STORM DRAINSD
STRUCTURAL CLAY TILESCT
SCREENSCRN
SCHEDULESCHED
SOLID CORESC
SECURITY BARSS.B.
SPLASH BLOCKSB
SUPPLY AIRSA
SOUTHS
RAINWATER CONDUCTORRWC
RIVETRVT
REVERSERVS
RUBBER TILE FLOORRTF
RAISED PATTERN RUBBER TILERPRT
REVOLUTIONS PER MINUTERPM
RETRACTABLE PARTITIONRP
RIGHT OF WAYROW
ROUGH OPENINGRO
ROUNDRND
ROOMRM
RAILINGRLG
RACKRK
ROOF HATCHRH
RIGHT HANDRH
RELATIVE HUMIDITYRH
ROOFINGRFG
REVISIONREV
RETURNRET
RESILIENTRESIL
REQUIREDREQD
REMOVE(ABLE)REM
REINFORCEREINF
REGLETREG
REGISTERREG
REFRIGERATIONREFR
REFLECTREFL
REFERENCEREF
RECTIFIERRECT
RECREATION ROOMREC ROOM
RECEPTACLERECPT
RIGID INSULATIONRDG INS
ROOF DRAINRD
RECEIVERRCVR
REINFORCED CONCRETE PIPERCP
REMOTE CONTROLRC
RUBBERRBR
RUBBLE STONERBL
RUBBER BASE, RESILIENT BASERB
RETURN AIR REGISTERRAR
RETURN AIR GRILLERA GR
RABBETEDRAB
RETURN AIRRA
RISERR
RANGER
RADIUSR
QUANTITYQTY
QUARTER ROUND1/4 RND
QUARTERQTR
QUARTQT.
QUARRY TILEQT
PASS WINDOWPW
PAVINGPVG
POLYVINYL CHLORIDEPVC
PAVEDPV
PAPER TOWEL RECEPTACLEPTR
PARTITIONPTN
PAPER TOWEL DISPENSERPTD
POST-TENSIONED CONCRETEPT CONC
POINTPT.
PNEUMATIC TUBEPT
POUNDS PER SQUARE INCHPSI
POUNDS PER SQUARE FOOTPSF THRES THRESHOLD
TK BD TACKBOARD
TKS TACKSTRIP
TO TOP OF
TOL TOLERANCE
TOPO TOPOGRAPHY
TOS TOP OF SLAB
TOS TOP OF STEEL
TOW TOP OF WALL
TPD TOILET PAPER DISPENSER
TPTN TOILET PARTITION
TRANS TRANSOM
TRANS TRANSVERSE
TSTAT THERMOSTAT
TV TELEVISION
TYP TYPICAL
UC UNIT COOLER
UGND UNDERGROUND
UH UNIT HEATER
UL UNDERWRITERS LABORATORIES
UNEX UNEXCAVATED
UNFIN UNFINISHED
UPS UNINTERRUPTABLE POWER SUPPLY
UR URINAL
UTIL UTILITY
UV UNIT VENTILATOR
V VOLT
VAR VARNISH
VB VINYL BASE
VCT VINYL COMPOSITION TILE
VCT VITRIFIED CLAY TILE
VD VAULT DOOR
VENT VENTILATOR(TION)
VERT VERTICAL
VEST VESTIBULE
VF VINYL FABRIC
VG VERTICAL GRAIN
VH VINYL HOMOGENEOUS
VJ V-JOINT(ED)
VNR VENEER
VOL VOLUME
VR VAPOR RETARDER
VRM VERMICULITE
VS VENT STACK
V.T. VOLTAGE TRANSFORMER
VTR VENT THRU ROOF
VWC VINYL WALL COVERING
W WEST
W/ WITH
WB WET BULB
WBL WOOD BLOCKING
WC WATER CLOSET
W/C WHEELCHAIR
WCO WOOD-CASED OPENING
WD WOOD
WD WOOD DOOR
WDSP WASTE DISPOSER
WDW WINDOW
WF WIDE FLANGE
WGL WIRED GLASS
WH WALL HUNG
WH WATER HEATER
WHB WHEEL BUMPER
WHM WATT-HOUR METER
WI WROUGHT IRON
WKSH WORK SHOP
WM WIRE MESH
W/O WITHOUT
WP WATERPROOF(ING)
WP WEATHERPROOF
WP WORKING POINT
WR WASTE RECEPTACLE
WRB WARDROBE
WS WATERSTOP
W.S. WASTE STACK
WSCT WAINSCOT
WT WEIGHT
WTH WIDTH
W/W WALL TO WALL
WWF WELDED WIRE FABRIC
WWM WELDED WIRE MESH
WWR WELDED WIRE REINFORCEMENT
XFMR TRANSFORMER
YD YARD
YD YARD DRAIN
IW INDUSTRIAL WASTE
COURSE(S)CRS
CROSS GRAINCRG
CORROSIVE RESISTANT STEELCRES
CIRCUMFERENCECRCMF
CARPETCPT
COMPRESSIBLECPRS
COVERCOV
CORRIDORCORR
CONTRACTORCONTR
CONTINUE CONT
CONSTRUCTIONCONSTR
CONNECTCONN
CONCRETECONC
COMPARTMENTCOMPT
COMBUSTIONCOMB
COMMONCOM
COLUMNCOL
CARBON DIOXIDECO2
CLEANOUTCO
COUNTERCNTR
CORNERCNR
CONDUCTIVE NEOPRENE LATEXCNL
CONDUITCND
CONCRETE MASONRY UNITCMU
COMPOSITECMPST
CORRUGATED METAL PIPECMP
CENTIMETER(S)cm
CLEAR WIRED GLASSCLWG
CLEAR(ANCE)CLR
CLOSURECLOS
CLOSETCLO
CONTRACT LIMIT LINECLL
CLEAR GLASSCLGL
CEILING HEIGHTCLG HT
CEILINGCLG
CENTER LINECL
CIRCUIT BREAKERCKT BRKR
CIRCUITCKT
CONSTRUCTION JOINTCJ
CONTROL JOINTCJ
CIRCULARCIRC
CAST-IN-PLACECIP
CURB INLETCI
CAST IRONCI
CHROME PLATEDCHR PL
CHECKCHK
CHIMNEYCHIM
CHAMFERCHFR
CHALKBOARDCH BD
CORNER GUARDCG
CUBIC FEET PER MINUTECFM
COUNTERFLASHINGCFLG
CONDUCTIVE FLOORINGCFI
CERAMICCER
CEMENT PLASTERCEM PLAS
CEMENTCEM
COVER ELEVATIONCE
CLOSED CIRCUIT TELEVISIONCCTV
CUBICLE CURTAIN TRACKCCT
CATCH BASINCB
CAPACITYCAP
CABINETCAB
BOTH WAYSBW
BUILT-UP ROOFINGBUR
BETWEENBTWN
BTU PER HOURBtuH
BRITISH THERMAL UNITBtu
BASEMENTBSMT
BOTH SIDESBS
BRONZEBRZ
BRACKETBRKT
BRICKBRK
BEARING PLATEBRG PL
BEARINGBRG
BRIDGINGBRDG
BRACINGBRCG
BACK PLASTER(ED)BP
BOTTOMBOT
BOTTOM OFBO
BENCHMARKBM
BELOWBLW
BUILDINGBLDG
BUILDING LINEBL
BED JOINTBJT
BITUMINOUSBITUM
BEVELBEV
BRICK EXPANSION JOINTBEJ
BOUNDARYBDRY
BOARDBD
BOOKCASEBC
BULLETIN BOARDBB
ACOUSTICAL WALL TREATMENTAWT
AMERICAN WIRE GAUGEAWG
AVERAGEAVG
AUTOMATICAUTO
ACOUSTICAL TILE CEILINGATC
ASPHALTASPH
ABOVE SUSPENDED CEILINGASC
ASBESTOSASB
AMERICAN REFRIGERATION INSTITUTEARI
ARCHITECTARCH
APPROXIMATEAPPROX
APPROVEDAPPD
AMERICAN NATIONAL STANDARDS INSTITUTEANSI
ANODIZEANOD
AMPEREAMP
AMBIENTAMB
ALUMINUMALUM
ALTERNATEALT
ACTIVE LEAFA.L.
AMERICAN INSTITUTE OF STEEL CONSTRUCTIONAISC
AMPERE INTERRUPTING CAPACITYAIC
AREA INLETAI
AIR HANDLING UNITAHU
ANCHOR AHR
AGGREGATEAGGR
ABOVE FINISHED FLOORAFF
AUTOMATIC DOOR OPERATORADO
ADJACENT, ADJOINING, ADJUSTABLEADJ
ADHESIVEADH
ADDENDUMADDM
ACOUSTICAL CEILING TILEACT
ACOUSTICACST
ALUMINUM CABLE STEEL REINFORCEDACSR
ACCESS PANELACS PNL
ACCESS DOORACS DR
ACRYLIC PLASTICACR
AMERICAN CONCRETE INSTITUTEACI
ACCESSIBLEACC
ALTERNATING CURRENTAC
ABOVEABV
ANCHOR BOLTAB
AIR CONDITIONING UNITA/C UNIT
AIR CONDITIONINGA/C
ANGLEL
A H
A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A B
B R
E V
IA
T
IO
N S
A N
S I
D
M
H O
F F
M A
N
G-002
M
H O
F F
M A
N
M
H O
F F
M A
N
M
H O
F F
M A
N
F E
B R
U A
R Y
W F
B
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
IL
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-101
S L
IN
D G
R E
N
E-101
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
O A
H E D
A M
O A
H E D
A M
L O
C A
T
IO
N P
L A
N L
O C
A T
IO
N P
L A
N
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
F E
B R
U A
R Y
F E
B R
U A
R Y
W F
B
W F
B
LINE 1
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
F
B
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
F
B
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-102
S L
IN
D G
R E
N
E-102
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
O A
H E D
A M
O A
H E D
A M
P A
R T
IA
L L
O C
A T
IO
N P
L A
N P
A R
T
IA
L L
O C
A T
IO
N P
L A
N
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
F E
B R
U A
R Y
F E
B R
U A
R Y
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-103
S L
IN
D G
R E
N
E-103
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
P O
W E
R H
O U
S E A
N D S
W
IT
C H
Y A
R D
P O
W E
R H
O U
S E A
N D S
W
IT
C H
Y A
R D
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
K V A
N D
K V P
O W
E R
H O
U S
E L
IN
E S P
L A
N
K V A
N D
K V P
O W
E R
H O
U S
E L
IN
E S P
L A
N
SWITCHYARD. SEE SHEET E-106 FOR CURRENT CONFIGURATION.
THIS DRAWING SHOWS THE ORIGINAL CONFIGURATION OF THE
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
MO67 83E501
REFERENCE DRAWING:
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-104
S L
IN
D G
R E
N
E-104
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S W
IT
C H
Y A
R D S
T R
U C
T U
R E
S S
W
IT
C H
Y A
R D S
T R
U C
T U
R E
S
L O
C A
T
IO
N P
L A
N L
O C
A T
IO
N P
L A
N
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
SWITCHYARD. SEE SHEET E-106 FOR CURRENT CONFIGURATION.
THIS DRAWING SHOWS THE ORIGINAL CONFIGURATION OF THE
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
REFERENCE DRAWING: MO67 86E101
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
F
B
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
F
B
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-105
S L
IN
D G
R E
N
E-105
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S W
IT
C H
Y A
R D P
L A
N S
W
IT
C H
Y A
R D P
L
N
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
SWITCHYARD. SEE SHEET E-106 FOR CURRENT CONFIGURATION.
THIS DRAWING SHOWS THE ORIGINAL CONFIGURATION OF THE
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
MO67 83E502
REFERENCE DRAWING:
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-106
S L
IN
D G
R E
N
E-106
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
IN
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
SWITCHYARD. SEE SHEET E-106 FOR CURRENT CONFIGURATION.
THIS DRAWING SHOWS THE ORIGINAL CONFIGURATION OF THE
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
R E
V
IS
E D S
W
IT
C H
Y A
R D L
A Y
O U
T R
E V
IS
E D S
W
IT
C H
Y A
R D L
A Y
O U
T
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-107
S L
IN
D G
R E
N
E-107
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S W
IT
C H
Y A
R D E
Q U
IP
M E
N T
S W
IT
C H
Y A
R D E
Q U
IP
M E
N T
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
K V S
W
IT
C H
Y A
R D E
L E
V A
T
IO
N S
K V S
W
IT
C H
Y A
R D E
L E
V A
T
IO
N S
MO67 83E503
REFERENCE DRAWING:
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-108
S L
IN
D G
R E
N
E-108
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
O U
T L
IN
E G
E N
E R
A L A
R R
A N
G E
M E
N T
O U
T L
IN
E G
E N
E R
A L A
R R
A N
G E
M E
N T
K
V P
O W
E R T
R A
N S
F O
R M
E R
K
V P
O W
E R T
R A
N S
F O
R M
E R
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
K V T
A K
E -O
F F S
T R
U C
T U
R E
K V T
A K
E -O
F F S
T R
U C
T U
R E
MO67 83E125
REFERENCE DRAWING:
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-109
S L
IN
D G
R E
N
E-109
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T S
W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
P O
W E
R H
O U
S E L
IN
E T
O W
E R N
O
K V
P O
W E
R H
O U
S E L
IN
E T
O W
E R N
O
K V
REFERENCE DRAWING: MO67 86E102
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-110
S L
IN
D G
R E
N
E-110
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T S
S W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T S
K
V S
W
IT
C H
Y A
R D
K
V S
W
IT
C H
Y A
R D
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
MO67 86E110
REFERENCE DRAWING:
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-111
S L
IN
D G
R E
N
E-111
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T
S W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T
K
V T
A K
E -O
F F S
T R
U C
T U
R E
K
V T
A K
E -O
F F S
T R
U C
T U
R E
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
REFERENCE DRAWING: MO67 86E111
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-112
S L
IN
D G
R E
N
E-112
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T
S W
IT
C H
Y A
R D S
T R
U C
T S
A
P P
U R
T
K
V T
A K
E -O
F F S
T R
U C
T U
R E
K
V T
A K
E -O
F F S
T R
U C
T U
R E
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
REFERENCE DRAWING: MO67 86E113
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-113
S L
IN
D G
R E
N
E-113
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S H
E E
T
S H
E E
T
O A
H E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E O
A H
E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E
B
IL
L O
F M
A T
E R
IA
L B
IL
L O
F M
A T
E R
IA
L
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
MO57-83MB104 SHEET 2
MO57-83MB104 SHEET 1
REFERENCE DRAWINGS:
*: EXISTING CONNECTION TO BE REPLACED AS INDICATED IN SPECIFICATIONS
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-114
S L
IN
D G
R E
N
E-114
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S H
E E
T
S H
E E
T
O A
H E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E O
A H
E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E
B
IL
L O
F M
A T
E R
IA
L B
IL
L O
F M
A T
E R
IA
L
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
MO57-83MB501 SHEET 2
MO57-83MB501 SHEET 1
REFERENCE DRAWINGS:
*: EXISTING CONNECTION TO BE REPLACED AS INDICATED IN SPECIFICATIONS
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-115
S L
IN
D G
R E
N
E-115
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S H
E E
T
S H
E E
T
O A
H E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E O
A H
E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E
B
IL
L O
F M
A T
E R
IA
L B
IL
L O
F M
A T
E R
IA
L
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
MO57-83MB501 SHEET 4
MO57-83MB501 SHEET 3
REFERENCE DRAWINGS:
*: EXISTING CONNECTION TO BE REPLACED AS INDICATED IN SPECIFICATIONS
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-116
S L
IN
D G
R E
N
E-116
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
O A
H E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E O
A H
E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E
B
IL
L O
F M
A T
E R
IA
L B
IL
L O
F M
A T
E R
IA
L
S H
E E
T
S H
E E
T
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
MO57-83MB501 SHEET 6
MO57-83MB501 SHEET 5
REFERENCE DRAWINGS:
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -1
.d g n
E-117
S L
IN
D G
R E
N
E-117
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
S H
E E
T
S H
E E
T
O A
H E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E O
A H
E R
E S
E R
V O
IR
-P
O W
E R
H O
U S
E
B
IL
L O
F M
A T
E R
IA
L B
IL
L O
F M
A T
E R
IA
L
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
MO57-83MB501 SHEET 7
REFERENCE DRAWING:
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
A H
A
N E
F
IL
E N
A M
E N
U M
B E
R
C
A P
IT
O L A
V E
O A
A E -6
.d g n
E-601
S L
IN
D G
R E
N
E-601
D
O T
T E
R B
Y
D
O T
T E
R B
Y
S L
IN
D G
R E
N
D
O T
T E
R B
Y
D
O T
T E
R B
Y
BE VERIFIED BY CONTRACTOR.
EXISTING CONDITIONS SHALL
FOR INFORMATION ONLY
CONTRACTOR SHALL ADJUST THE SCALES ACCORDINGLY.
IF ANY OTHER SIZE DRAWINGS ARE FURNISHED OR PLOTTED THE
OF 28" X 40" OR METRIC DRAWING SIZE OF 841mm X 594mm.
ALL SCALES SHOWN ARE BASED ON A STANDARD DRAWING SIZE
EQUIPMENT SHALL BE AS REQUIRED BY THE SPECIFICATIONS.
LOCATIONS ONLY. SCOPE AND REQUIREMENTS FOR NEW
THESE DRAWINGS SHOW EXISTING CONDITIONS AND
J
C H
A M
B E
R L
A
IN
J
C H
A M
B E
R L
A
IN
O M
A H
A D
IS
T R
IC
T O
M A
H A D
IS
T R
IC
T
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
O A
H E D
A M S
O U
T H D
A K
O T
A
P O
W E
R H
O U
S E L
IN
E
A N
S I
D A
N S I
D
P O
W E
R P
L A
N T E
Q U
IP
M E
N T
P O
W E
R P
L A
N T E
Q U
IP
M E
N T
O N
E -L
IN
E D
IA
G R
A M
O N
E -L
IN
E D
IA
G R
A M
W F
B
W F
B
F E
B R
U A
R Y
F E
B R
U A
R Y
| GENERAL | |
| G-001 | COVER & INDEX (1) |
| G-002 | ABBREVIATIONS (1) |
| ELECTRICAL | |
| E-101 | OAHE DAM - LOCATION PLAN (1) |
| E-102 | OAHE DAM - PARTIAL LOCATION PLAN (1) |
| E-103 | POWERHOUSE AND SWITCHYARD 115KV AND 230KV POWERHOUSE LINES - PLAN (1) |
| E-104 | SWITCHYARD STRUCTURES LOCATION PLAN (1) |
| E-105 | SWITCHYARD PLAN (1) |
| E-106 | REVISED SWITCHYARD LAYOUT (1) |
| E-107 | SWITCHYARD EQUIPMENT 115KV SWITCHYARD ELEVATIONS (1) |
| E-108 | 115KV TAKE-OFF STRUCTURE 115 KV POWER TRANSFORMER OUTLINE & GENERAL ARRANGEMENT (1) |
| E-109 | SWITCHYARD STRUCTS. & APPURT POWERHOUSE LINE TOWER NO. 1 115KV (1) |
| E-110 | SWITCHYARD STRUCTS. & APPURTS. 115 KV SWITCHYARD (1) |
| E-111 | SWITCHYARD STRUCTS. & APPURT. 115 KV TAKE-OFF STRUCTURE (1) |
| E-112 | SWITCHYARD STRUCTS. & APPURT. 115 KV TAKE-OFF STRUCTURE (1) |
| E-113 | OAHE RESERVOIR-POWERHOUSE BILL OF MATERIAL SHEET 1 (1) |
| E-114 | OAHE RESERVOIR-POWERHOUSE BILL OF MATERIAL SHEET 2 (1) |
| E-115 | OAHE RESERVOIR-POWERHOUSE BILL OF MATERIAL SHEET 3 (1) |
| E-116 | OAHE RESERVOIR-POWERHOUSE BILL OF MATERIAL SHEET 4 (1) |
| E-117 | OAHE RESERVOIR-POWERHOUSE BILL OF MATERIAL SHEET 5 (1) |
| E-601 | POWER PLANT EQUIPMENT ONE-LINE DIAGRAM (1) |