Amd0002 Drawings - FP75E-600.pdf
PDF 276 KB Posted
- Attached to
- Fort Peck Shaft Building Conductor Replacement Federal contract opportunity
- Solicitation number
- W9128F21B0023
About this file
This solicitation package describes a requirements contract opportunity with the U.S. Army Corps of Engineers Omaha District. The scope of work involves replacing normal and emergency feeders between the powerhouse and shaft buildings at Fort Peck Dam in Montana to include installation of sectionalizing cabinets. The estimated construction cost ranges from $500,000 to $1,000,000. Offerors must be small businesses under NAICS code 238210 with a size standard of $16.5 million. The solicitation will close on September 24, 2021 and the contract completion date is 365 calendar days from notice to proceed. Interested parties can access solicitation documents through the System for Award Management website. The place of performance is Fort Peck, Montana and the contracting office is the USACE Omaha District.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Revised Abstract of Bids - W9128F21B0023 - Shaft Building Conductors.pdf | ||
| Signed Abstract - W9128F21B0023 - Shaft Building Conductors.pdf | ||
| Amd0002 - W9128F21B0023 - Replace Shaft Building Conductors Ft Peck.pdf | ||
| Amd01 - W9128F21B0023 Replace Shaft Building Conductors Ft Peck.pdf | ||
| Am0001 Shaft Conductor Reference Drawings.pdf | ||
| Site Visit Attendee List W9128F21B0023.pdf | ||
| Dwgs - W9128F21B0023 Replace Shaft Building Conductors Ft Peck.PDF | ||
| 1of2 - W9128F21B0023 Replace Shaft Building Conductors Ft Peck.pdf | ||
| 2of 2 - Specifications for W9128F21B0023 Replace Shaft Building Conductors Ft Peck.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
CB5
CB5 MC1
250A
MC 4
225A
MC 2
225A
EC 1
225A
MC 3
225A
EC 3
225A
EC 2
225A 225A
EC 4
225A 50A
2 3 4 5 6 7 8 9 10 11
PP
PNL
OH
678 658 648 638 618 652 654 646 634 656 662
636632642 D1 D2
D3D4
4160V
480V KW
GENERATOR
DIESEL
4160V
ELECTRICAL INTERLOCK
25A
R
17.5
R
R
480 / 120
LGT PNL.
SHAFT SUB
LTS 91-106
SHAFT HILL RD
CHEST LTG. LTS 1-14
LTS 15-35
CHEST LTG.
LTS 36-60
CHEST LTG.
LTS 61-90
CHEST LTG.
MFP-OPN83E301
SEE
CONTINUATION
13.8 KV FOR
TRANS "A"
4160V
SOUTH OF PLANTS
POLE STRUCTURE
3Ø
500KV
SWGR
STA SERV
TO 480V
H & V SWGR
TO 480V
SWGR
STA SERV
TO 480V
3Ø
750 KVA
3Ø
750 KVA
TRANF 1
STA SERV
H & V SUBSTA
TRANF 2
STA SERV
3Ø
750 KVA
3Ø
750 KVA
3Ø
750 KVA
480V SWITCHGEAR
480V POWER TO
4160V
TRANS "B"
4160V
3Ø
2 MVA
ELECTRICAL INTERLOCK
PLANT NO. 2PLANT NO. 1
MFP-OPN-83E302
ONE-LINE DIAGRAM
MAIN POWER SYSTEM
SEE PLANT TWO
FOR CONTINUATION
13.8 KV
3Ø
2 MVA
40'-4"
GO-65 KF-4
3Ø
4160 / 480
KT11
INTERPRETATIVE CENTER
3Ø
4160 / 480
KT1
ROAD LIGHTS
EAST LOWER YELLOWSTONE
480 / 120
DUMP STATION LIGHT
ROAD LIGHTS
WEST LOWER YELLOWSTONE
SHELTER HOUSES 3 & 4
HORSE SHOE PIT &
BREAKER BOX
GO-25 KF-3
OH
4160V
KW
GENERATOR
DIESEL
35A
4160V
4160V
CL-1
3Ø
750 KVA
1000AEC=EMERG. CONTROL BLDG.
MC=MAIN CONTROL BLDG.
480 V
POWER PLANTS
1Ø
BUILDING
ADMINISTRATIVE
TO FORT PECK
SPILLWAY
TO FORT PECK
S O
L
IC
IT
A T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S
IZ
E
S U
B M
IT
T E
D B
Y
D A
T E
C O
N T
R A
C T N
O
C H
E C
K E
D B
Y
D R
A W
N B
Y
IS
S
U E D
A T
E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
KEYED NOTES:
# SIZE
EMERGENCY FEEDER UG
MAIN FEEDER UG
UG
UG
001 003
CABLE & CONDUIT SCHEDULE
GENERAL NOTES:
GENERATOR RECEPTACLE REQUIREMENTS.
1. REFERENCE SPECIFICATION SECTION 26 00 00.00 26, PARAGRAPH 2.3 FOR
10011
00110011
3#350 MCM - 5KV
3#4/0 AWG - 5KV
(SEE KEYED NOTE 3)
THREE-WAY SECTIONALIZING CABINET
(SEE KEYED NOTE 2)
TWO-WAY SECTIONALIZING CABINET
BOOT PARKED
BOOT CONNECTED
003 3#4/0AWG, 1#6AWG GROUND - 5KV
004 3#4/0 AWG - 5KV, 1-4INCH PVC.
ADMIN BUILDING
MAIN FEED TO
SHAFTS UG
MAIN FEED TO
TO SHAFTS
EMERGENCY FEEDER
CONDUCTORS AS SPECIFIED IN THE CABLE AND CONDUIT SCHEDULE.
7. PROVIDE NEW CONNECTION BETWEEN CABINETS WITH 4INCH CONDUIT AND
BETWEEN THREEWAY SECTIONALIZING CABINET. INSTALL IN 4IN PVC.
6. PROVIDE/INSTALL NEW THREE (3) 4/0 AWG MV-105 5KV EPR INSULATION CU CABLES
5KV EPR INSULATION CU CABLES.
5. DEMO THE EXISTING CABLES. PROVIDE/INSTALL NEW THREE (3) 350 MCM MV-105
SHEETS E-502.
4. PROVIDE/INSTALL NEW TRANSITION FROM UG TO OH. ACCORDING TO DETAILS ON
3. PROVIDE/INSTALL ONE (1) THREEWAY SECTIONALIZING CABINET OR EQUIVALENT.
2. PROVIDE/INSTALL ONE (1) SECTIONALIZING CABINET OR EQUIVALENT.
EPR INSULATION CU CABLES.
1.DEMO THE EXISTING CABLES. PROVIDE/INSTALL NEW THREE (3) 4/0 AWG MV-105 5KV
DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg8:32:02 AM 9/21/2021
...\30500 - Construction E&D\FP75\30DA0 - Plans & Specs\CAD_BIM\_Sheets\CAD_
O M
A H
A
N E
F
IL
E N
A M
E
®of Engineers
US Army Corps
U .S
A R
M Y C
O R
P S O
F E
N G
IN
E E
R S
C
A P
IT
O L A
V E
F
IL
E N
U M
B E
R
F P E -6
.d g n
O M
A H
A D
IS
T R
IC
T
F O
R T P
E C
K D
A M
M O
N T
A N
A
R E
P L
A C
E S
H A
F T B
U
IL
D
IN
G C
O N
D U
C T
O R
S
A N
S I
D
E-600
O N
E -L
IN
E D
IA
G R
A M
J
M O
E N
C H
J
M O
E N
C H
F P
D -4
W F
B
S L
IN
D G
R E
N
S L
IN
D G
R E
N
A U
G U
S T
A M G
E N
E R
A L R
E V
IS
IO
N S
-2
-2
File details come from the government source that posted it. Updated .