Spillway Foundation Piezometer Repair Gavins Point Dwgs.pdf

PDF 28 MB Posted

Attached to
Spillway Foundation Piezometer Repairs at Gavins Point Dam, SD.
Solicitation number
W9128F20Q0057
Issued by

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

R

O

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg4:15:44 PM 6/26/2020

...\30500 - Construction E&D\GP78\30DA0 - Plans & Specs\CAD_BIM\_Sheets\3 of Engineers

US Army Corps

Omaha District

G-001

MISSOURI RIVER

GAVINS POINT DAM, SOUTH DAKOTA

SPILLWAY FOUNDATION PIEZOMETER REPAIRS

C O

V E

R S

H E

E T

A

B A

R R

Y

A

B A

R R

Y

K

H E

D D

E N

S

K

H E

D D

E N

S

CONTRACT ADVERTISEMENT SET

CONTRACT ADVERTISEMENT SET

W9128F-20-Q-0057SOLICITATION NO.:

CONTRACT NO.:

1 JULY 2020ISSUE DATE:

VICINITY MAP

PROJECT LOCATION MAP

NO.

INDEX OF DRAWINGS

TITLE

NO. TITLE

GAVINS POINT DAM SPILLWAY, SOUTH DAKOTA

GAVINS POINT DAM SPILLWAY, SOUTH DAKOTA

0 10 20 30 MI

REFERENCE DRAWINGS

DWG. NO.

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg4:30:11 PM 6/26/2020

IN

D

E X O

F D

R A

W

IN

G S

V

IC

IN

IT

Y P

R O J E

C T L

O C

A T

IO

N M

A P

GI001

MG5-51E60.3

MG5-51E59.3

MG5-51E55.4

MG5-51E54.3

MG5-57E2.3

MG5-51E48.3

MG5-51E46.3

MG5-51E21.2

MG5-51E17.4

MG5-51E3.4

MG5-51E2.6

MG5-51E1.3

RCF12

RCF11

RCF10

RCF09

RCF08

RCF07

RCF06

RCF05

RCF04

RCF03

RCF02

RCF01

MISC. CONCRETE DETAILS - SHEET 2

MISC. CONCRETE DETAILS - SHEET 1

STILLING BASIN SLAB & REINF. DETAILS

CHUTE SLAB CONC. & REINF. DETAILS

SPILLWAY DRAINAGE & PIPING PLANS & DETAILS

SOUTH WALL CONC. DETAILS - BLOCKS S12 THRU S16

SOUTH WALL CONC. DETAILS - BLOCKS S6 THRU S11

NORTH WALL CONC. DETAILS - BLOCKS N12 THRU N17

NORTH WALL CONC. DETAILS - BLOCKS N6 THRU N11

STRUCTURAL ARRANGEMENT - SOUTH WALL PROFILE

STRUCTURAL ARRANGEMENT - NORTH WALL PROFILE

STRUCTURAL ARRANGEMENT - PLAN & ELEVATIONS

T-500

T-100

S-500

S-100

GI-001

G-001

FIBER OPTIC REPAIR DETAILS

FIBER OPTIC REPAIR PLAN

STRUCTURAL REPAIR DETAILS

STRUCTURAL REPAIR PLAN

VICINITY AND PROJECT LOCATION MAP, INDEX OF DRAWINGS

COVER SHEET

K

H E

D D

E N

S

K

H E

D D

E N

S

A

B A

R R

Y

A

B A

R R

Y

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg11:07:39 AM 7/1/2020

S-100

J

O S

B O

R N

J

O S

B O

R N

S T

R U

C T

U R

A L R

E P

A

IR

P

L A

N

W

B O

E C

K

W

B O

E C

K

CALENDAR DAYS. MORE TIME MAY POSSIBLY BE ALLOWED UPON COORDINATION.

WITH THE CONTRACTING OFFICER. SPALL REPAIRS ARE EXPECTED TO TAKE APPROXIMATELY TEN

MAINTENANCE AND INSPECTIONS. CONSTRUCTION TIME FRAME AND WORK SHALL BE COORDINATED

3. THE SPILLWAY GATES ARE TYPICALLY ALWAYS OPEN AND ARE TYPICALLY ONLY CLOSED FOR

2. SEE S-500 FOR REPAIR DETAILS AND NOTES.

1. SEE TABLE AND PLAN ON THIS SHEET FOR REPAIR LOCATIONS AND EXTENTS.

SPILLWAY CHUTE REPAIR NOTES:

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

PATCH # SIZE DEPTH

SPILLWAY CHUTE REPAIR TABLE

6"

1'-0" X 1'-0" 6" + 1 CUBIC YARD

REMOVAL WITH THE CONTRACTING OFFICER'S REPRESENTATIVE.

*SIZE OF PATCH IS APPROXIMATE. COORDINATE EXTENTS OF CONCRETE

4'-6" X 3'-6" *

FILL VOID

SPALL REPAIR

REPAIR TYPE

SPILLWAY REPAIR PLAN

VARIES

M

IN

2"

T O W

A T

E R

S T

O P

M

IN

8"

8"

2"

PATCH BOUNDARY

APPROXIMATE

PATCH BOUNDARY

APPROXIMATE

ALIGNMENT

PZ-S-5 CHANNEL

APPROXIMATE

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg11:08:36 AM 7/1/2020

S-500

SHEET ID

T

R U

C T

U R

A L R

E P

A

IR

D

E T

A

IL

S

G P S -5

.d g n

J

O S

B O

R N

J

O S

B O

N

PHOTO 1: PATCH #1 - SPALL REPAIR

PHOTO 2: PATCH #2 - VOID REPAIR

PHOTO 3: PATCH #2 - VOID REPAIR

W

B O

E C

K

W

B O

E C

K

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REINFORCEMENT

EXISTING SLAB

SPILLWAY SLAB

EXISTING

SPILLWAY WALL

EXISTING

WATERSTOP

EXISTING COPPER

REPAIR SURFACE

BOTTOM OF CONCRETE

SPALL REPAIR DETAIL

SECTION

PLAN

PERIMETER SAWCUT

SPILLWAY WALL

SPILLWAY SLAB

2" SAWCUT

CONCRETE 4" WITH EPOXY

SPACE EMBEDED INTO EXISTING

#4 BARS @ MAX 8" O.C.E.W. EVENLY

CONCRETE 4" WITH EPOXY

SPACE EMBEDED INTO EXISTING

#4 BARS @ MAX 8" O.C.E.W. EVENLY

REQUIREMENTS FOR PLACING CONCRETE IN COLD WEATHER.

8. SPALL REPAIR WORK IS ANTICPATED TO OCCUR IN DECEMBER. SEE SPECIFICATION 03 30 00 CAST-IN-PLACE CONCRETE FOR

PHOTO 1.

SHAPED CHANNEL TO CONNECT THE EXISTING SAW CUTS FOR PZ-S-5 AS APPROXIMATED IN THE ALIGNMENT SHOWN ON

7. A MINIMUM OF 24 HOURS AFTER CONCRETE PLACEMENT. THE CONTRACTOR SHALL SAW CUT A 3/8 IN WIDE X 2 IN DEEP U-

REQUIREMENTS.

6. SEE SECTION 03 01 00 REHABILITATION OF CONCRETE AND 03 30 00 CAST-IN-PLACE CONCRETE FOR ADDITIONAL

5. WET CURE CONCRETE UNTIL THE SPILLWAY GATES ARE OPEN OR FOR A MINIMUM OF 10 DAYS, WHICHEVER COMES FIRST.

CONTRACTING OFFICER'S REPRESENTATIVE.

DURING CONCRETE REMOVAL OR REINFORCEMENT IS UNUSABLE. COORDINATE REINFORCEMENT REPLACEMENT WITH THE

4. SEE DETAIL A5/S-500 FOR REBAR REPLACEMENT. REPLACE REINFORCEMENT WHERE EXISTING REINFORCEMENT IS DAMAGED

SPILLWAY WALL.

CLEAN, AND OPEN PORE SURFACE. APPLY BONDING AGENT TO EXISTING CONCRETE SURFACE WITH THE EXCEPTION OF THE

3. PRIOR TO CONCRETE PLACEMENT, CLEAN EXPOSED CONCRETE SURFACES AND REINFORCEMENT TO ACHIEVE A SOUND, CONTRACTING OFFICER FOR DIRECTION.

THE DAMAGED OR DELETERIOUS CONCRETE EXTENDS 6 INCHES BEYOND THE CONCRETE SURFACE INFORM THE

CONCRETE. CONCRETE REMOVAL SHALL EXTEND 6 INCHES DEEP FROM THE ORIGINAL UNDAMAGED CONCRETE SURFACE. IF

2. REMOVE CONCRETE WITH CHIPPING HAMMER. CONCRETE REMOVAL SHALL INCLUDE ALL DELETERIOUS AND DAMAGED

CONCRETE REPAIR EXTENTS TO ENSURE THAT NO LOOSE CONCRETE EXISTS OUTSIDE OF THE REMOVAL AREA.

IN SHAPE AND RUN PERPENDICULAR OR PARALLEL TO THE EXISTING SPILLWAY JOINTS. HAMMER SOUND AROUND THE

REMOVAL. SAW CUT LINES SHALL BE LOCATED ALONG PAINTED AREAS OF EXTENTS. SAW CUT LINES SHALL BE RECTANGULAR

EXTENTS FOR REMOVAL TO BE APPROVED BY THE CONTRACTING OFFICER'S REPRESENTATIVE PRIOR TO CONCRETE

1. SEE PHOTOS FOR APPROXIMATE SAW CUT LINE LOCATIONS. CONTRACTOR SHALL PERFORM SOUNDING AND PAINT AREAS OF

SPALL REPAIR NOTES:

COMPLETELY FULL. THIS WILL BE DONE AT THE SAME TIME THAT THE PATCH REPAIR IS MADE.

EXTENT WILL BE REPAIRED BY FILLING THE VOID WITH PATCH REPAIR MATERIAL UNTIL THE VOID IS

THE CONTRACTING OFFICER FOR DIRECTION. UNLESS DIRECTED OTHERWISE, THE VOID BEYOND THIS

2. IF THE VOID EXTENDS BEYOND 6 INCHES FROM THE ORIGINAL UNDAMAGED CONCRETE SURFACE INFORM

NOTES AND DETAIL ON THIS SHEET.

1. REPAIR VOID BY REMOVING CONCRETE APPROXIMATELY TO THE LINE SHOWN . FOLLOW THE SPALL REPAIR

PATCH #2 - VOID REPAIR NOTES:

THE JUNCTION BOX

TO EXISTING CABLE AT

TO BE FUSION SPLICED

NEW FIBER OPTIC CABLE

SHOWN ON SHEET T-500.

IN SAW CUT. REPLACE AS

NEW FIBER OPTIC CABLE

REMOVE EPOXY TO PLACE

SHOWN ON SHEET T-500.

IN SAW CUT. REPLACE AS

NEW FIBER OPTIC CABLE

REMOVE EPOXY TO PLACE

CLOSURE

AND PROTECTED WITH A SPLICE

EXISTING 6" DIAMETER BORING

EXISTING TWO CABLES AT

TO BE FUSION SPLICED TO

TWO NEW FIBER OPTIC CABLES

CLOSURE

AND PROTECTED WITH A SPLICE

EXISTING 6" DIAMETER BORING

EXISTING TWO CABLES AT

TO BE FUSION SPLICED TO

TWO NEW FIBER OPTIC CABLES

BOX

CABLES AT THE JUNCTION

SPLICED TO TWO EXISTING

CABLES TO BE FUSION

TWO NEW FIBER OPTIC

JUNCTION BOX

EXISTING CABLES AT THE

TO BE FUSION SPLICED TO TWO

TWO NEW FIBER OPTIC CABLES

PZ-S-3

PZ-S-9

T-3

PZ-S-4

PZ-S-6

T-1

PZ-S-5

T-4

PLACE. SEE NOTE 2.

CABLES TO BE LEFT IN

EXISTING FIBER OPTIC

PLACE. SEE NOTE 2.

CABLES TO BE LEFT IN

EXISTING FIBER OPTIC

NOTES:

RECOMMENDATIONS.

INSTALL ALL MATERIAL PER MANUFACTURER'S INSTALLATION REQUIREMENTS AND 1.

2.

ADDITIONAL COST TO USACE.

THE CONTRACTOR IS RESPONSIBLE FOR REPAIRING THE FIBER OPTIC CABLE AT NO

ARE DAMAGED WHILE THE CONTRACTOR IS WORKING AND NO LONGER FUNCTION,

INSTRUMENTS WILL BE READ DAILY BY USACE. IF ANY OF THE FIBER OPTIC CABLES

FUNCTIONALITY OF INSTRUMENTS PRIOR TO THE BEGINNING OF WORK. THE

THE CONTRACTOR DURING THE WORK. USACE WILL VERIFY AND DOCUMENT

FUNCTIONING AND NOT WITHIN IN THE SCOPE OF WORK WILL BE PROTECTED BY

EXISTING FIBER OPTIC CABLES WITHIN THE SAW CUTS OR CONDUITS THAT ARE

AS SHOWN ON SHEET T-500.

CABLES IN SAW CUT. REPLACE

TWO NEW FIBER OPTIC

REMOVE EPOXY TO PLACE

3.

CONTRACT.

REMOVE AND DISPOSE OF THE FIBER OPTIC CABLE TO BE REPLACED UNDER THIS

EXISTING EPOXY AND REPLACE

DETERIORATE. REMOVE

EPOXY IS BEGINNING TO

PLACE. SEE NOTE 2.

CABLES TO BE LEFT IN

EXISTING FIBER OPTIC

AS SHOWN ON SHEET T-500.

CABLES IN SAW CUT. REPLACE

TWO NEW FIBER OPTIC

REMOVE EPOXY TO PLACE

SCALE IN FEET

0 40 80

LEGEND

TABLE OF FIBER OPTIC LINE REPAIRS

SPILLWAY INSTRUMENTATION REPAIR PLAN

PZ-S-9 PROFILE REPAIR PLAN

PZ-S-5 PROFILE REPAIR PLAN

WITHIN CONDUIT

FIBER OPTIC REPLACEMENT

TO BE LEFT IN PLACE

EXISTING FIBER OPTIC

REPLACEMENT

EPOXY SEALANT

REPLACEMENT WITHIN SAW CUT

FIBER OPTIC AND EPOXY SEALANT

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

T-100

F

IB

E R O

P T

IC

R

E P

A

IR

P

L A

N

K

H E

D D

E N

S

K

H E

D D

E N

S

A

B A

R R

Y

A

B A

R

Y

DS: AEC_Screen.dscriptPD: AEC_pdf.pltcfg11:08:29 AM 7/1/2020

T-500

F

IB

E R O

P T

IC

R

E P

A

IR

D

E T

A

IL

S

FIBER OPTIC CABLE

FUSION SPLICE NEW AND EXISTING

PZ-S-9 CONDUIT & JUNCTION BOX TO INSIDE OF JUNCTION BOX

K

H E

D D

E N

S

K

H E

D D

E N

FAILED EPOXY SEALANT

PZ-S-9 SAW CUT CHANNEL WITH

A

B A

R R

Y

A

B A

R R

Y

CLOSURE BOX. PLACE THE SPLICE CLOSURE BOX IN THE EXISTING JUNCTION BOXES.

- FUSION SPLICE TWO NEW FIBER OPTIC CABLES TO THE EXISTING TWO CABLES AND PROTECT THE FUSION SPLICE WITH A SPLICE

FIBER OPTIC CABLE FUSION SPLICE AT TWO EXISTING JUNCTION BOXES

- SEE SECTION 03 01 00 REHABILITATION OF CONCRETE AND 03 30 00 CAST-IN-PLACE CONCRETE FOR ADDITIONAL REQUIREMENTS.

- WET CURE CONCRETE UNTIL THE SPILLWAY GATES ARE OPEN OR FOR A MINIMUM OF 10 DAYS, WHICHEVER COMES FIRST.

OPEN PORE SURFACE. APPLY BONDING AGENT TO EXISTING CONCRETE SURFACE WITH THE EXCEPTION OF THE SPILLWAY WALL.

- PRIOR TO CONCRETE PLACEMENT, CLEAN EXPOSED CONCRETE SURFACES AND REINFORCEMENT TO ACHIEVE A SOUND, CLEAN, AND

GRAVEL MATERIAL.

FUSION SPLICE WITH A SPLICE CLOSURE BOX. PLACE THE SPLICE CLOSURE BOX IN THE BORE HOLE AND BURY WITH THE REMOVED

- REMOVE 6" OF THE GRAVEL MATERIAL. FUSION SPLICE TWO NEW FIBER OPTIC CABLES TO THE EXISTING TWO CABLES AND PROTECT THE

A CHIPPING HAMMER.

EXTEND TO THE GRAVEL MATERIAL AS SHOWN IN THE PHOTO ABOVE. REMOVE FEATHERED, DELETERIOUS AND DAMAGED CONCRETE WITH

- CORE DRILL TO REMOVE 6" DIAMETER CONCRETE PLUG ABOVE THE BORE HOLE FOR THE PIEZOMETERS. CONCRETE REMOVAL SHALL

FIBER OPTIC CABLE FUSION SPLICE AT PIEZOMETER BORE HOLES PZ-S-5 AND PZ-S-9

DETAILS OF THE FIBER OPTIC CABLE FUSION SPLICES ARE AS FOLLOWS:5.

SAW CUT ALIGNMENTS AS DETAILED IN THE "EPOXY SEALANT REPLACEMENT NOTES."

RUN THE NEW FIBER OPTIC CABLE FROM THE PIEZOMETER BORE HOLES TO THE EXISTING JUNCTION BOXES ALONG THE EXISTING 4.

REPLACING THE FIBER OPTIC CABLE AND EPOXY SEALANT REPLACEMENT AT NO ADDITIONAL COST TO USACE.

CABLE FROM THE PIEZOMETER BORE HOLES TO THE EXISTING JUNCTION BOXES IS SHORT, THE CONTRACTOR IS RESPONSIBLE FOR

SPECIFIED IN THE DRAWINGS AND SPECIFICATIONS DUE TO INEFFICIENCIES IN FIBER OPTIC CABLE PLACEMENT. IF THE NEW FIBER OPTIC

THE CONTRACTOR IS RESPONSIBLE FOR DETERMINING IF ADDITIONAL FIBER OPTIC CABLE LENGTH IS REQUIRED FROM WHAT IS 3.

SPLICES TO MAINTAIN THE AIR TEMPERATURE ABOVE 40° F.

IF OUTSIDE TEMPERATURES ARE BELOW 40° F, ERECT A HEATED SHELTER AT THE LOCATION OF THE FIBER OPTIC CABLE FUSION 2.

SPLICES (FOUR TOTAL) WILL OCCUR AT BORE HOLES FOR PIEZOMETERS PZ-S-5 AND PZ-S-9.

FUSION SPLICES (FOUR TOTAL) WILL OCCUR AT TWO EXISTING JUNCTION BOXES OUTSIDE OF THE SPILLWAY SLAB AND TWO FUSION

A TOTAL OF EIGHT FUSION SPLICES WILL BE REQUIRED TO REPLACE FOUR FIBER OPTIC CABLES. AS SHOWN IN DRAWING T-100, TWO 1.

FIBER OPTIC REPAIR NOTES:

CONCRETE PLUG

BEFORE PLACEMENT OF

PIEZOMETER BORE HOLE

RESPONSIBLE FOR REPAIRING THE FIBER OPTIC CABLE AT NO ADDITIONAL COST TO USACE.

FIBER OPTIC CABLES ARE DAMAGED WHILE THE CONTRACTOR IS WORKING AND NO LONGER FUNCTION, THE CONTRACTOR IS

WORK WILL BE PROTECTED BY THE CONTRACTOR DURING THE WORK. THE INSTRUMENTS WILL BE READ DAILY BY USACE. IF ANY OF THE

EXISTING FIBER OPTIC CABLES WITHIN THE SAW CUTS OR CONDUITS THAT ARE FUNCTIONING AND NOT WITHIN IN THE SCOPE OF 8.

AREAS OF SEAL COMPRIMISED BY VOIDS, GAPS, CRACKS, BULGES, BLOW OUTS, FLOW OUTS, ETC.

WHERE CURRENT SEAL IS IN GOOD CONDITION DO NOT DISTURB OR REPLACE SEAL. REPAIR ONLY DIRECTLY AFFECTED AREAS PLUS ANY

- REMOVE AND REPLACE DETERIORATING EPOXY FROM PZ-S-4 TO BASE OF NOSE PIER (1/2 IN WIDE X 2.5 IN DEEP SAW CUT). IN AREAS

REPLACING DETERIORATING EPOXY SEALANT FOR PZ-S-4

(1/2 IN WIDE X 2.5 IN DEEP SAW CUT). NINE (9) EXISTING CABLES TO REMAIN IN PLACE.

- REPLACE TWO (2) PZ-S-9 FIBER OPTIC CABLES FROM INTERSECTION OF PZ-S-9 WITH T-3 AND PZ-S-3 TO ELEVATION 1190 ON NOSE PIER 9

CUT).

- REPLACE TWO (2) PZ-S-9 FIBER OPTIC CABLES FROM BORE HOLE TO INTERSECTION WITH T-3 AND PZ-S-3 (3/8 IN WIDE X 2 IN DEEP SAW

SPLICING NEW FIBER OPTIC CABLE FOR PZ-S-9

DEEP SAW CUT). SEVEN (7) EXISTING CABLES TO REMAIN IN PLACE.

- REPLACE TWO (2) PZ-S-5 FIBER OPTIC CABLES FROM INTERSECTION OF PZ-S-5 WITH T-1 TO TOP OF SOUTH WALL (1/2 IN WIDE X 2.5 IN

- REPLACE TWO (2) PZ-S-5 FIBER OPTIC CABLES FROM BORE HOLE TO INTERSECTION WITH T-1 (3/8 IN WIDE X 2 IN DEEP SAW CUT).

SPLICING THE NEW FIBER OPTIC CABLE FOR PZ-S-5.

- THE CONCRETE FOR PATCH REPAIR #1 - SPALL REPAIR MUST BE PLACED AND THE FIBER OPTIC CABLE ALIGNMENT SAW CUT PRIOR TO

SPLICING NEW FIBER OPTIC CABLE FOR PZ-S-5

DETAILS OF THE EXISTING SAW CUTS ARE AS FOLLOWS:7.

A LEVEL SURFACE. LEAKAGE FROM THE SIDE OF THE SAW CUTS MUST BE STOPPED.

EPOXY MUST LAY BELOW THE CONCRETE SURFACE (APPROXIMATELY 1/8TH INCH) WITH THE UPPER SURFACE TOOLED SMOOTHLY TO 6.

NO RUNNING WATER SHOULD BE ALLOWED ONTO SAW CUTS BEING REPAIRED. 5.

SPALLS, ETC. SAW CUT CHANNELS WIDTH SHOULD BE KEPT TO A MINIMUM.

THE SAW CUT CHANNEL PROFILE SHOULD BE U-SHAPED AND IN GOOD CONDITION FREE FROM BROKEN EDGES, DELAMINATIONS, 4.

ARE RECOMMENDED.

WHICH WOULD INHIBIT A BOND WITH THE EPOXY. ABRASIVE BLASTING, WATER BLASTING, OR WIRE BRUSHING FOR SURFACE PREPARATION

SAW CUT CHANNELS TO BE REPAIRED MUST BE CLEANED AND FREE OF LAITANCE, GREASE, OIL AND ANY OTHER CONTAMINANTS 3.

TEMPERATURE TO BE DEFINED BY THE MANUFACTURER OF THE EPOXY SEALANT PRODUCT.

INSTALLATION OF EPOXY WILL BE PERFORMED WHEN WEATHER CONDITIONS ARE AT OR ABOVE THE LOWEST ALLOWABLE 2.

FOR THIS APPLICATION. SET TIME OF EPOXY SHOULD BE APPROXIMATELY 30 MINUTES.

EPOXY MUST MEET REQUIREMENTS OF ASTM C881, TYPES I AND IV, GRADE 3, CLASS A. FAST SETTING (FS) EPOXY IS NOT REQUIRED 1.

EPOXY SEALANT REPLACEMENT NOTES:

" < A < 1/2")JOINT WIDTH (1/4

SUBSTRATE (TYP.)

NEW SEALANT

NEW BACKER-ROD

AND RECOMMENDATIONS.

INSTALL ALL MATERIAL PER MANUFACTURER'S INSTALLATION REQUIREMENTS7.

PRIME AND PREPARE SURFACES PRIOR TO INSTALLATION OF SEALANT.6.

BACKER-ROD (CLOSED-CELL) SIZE 25% LARGER THAN JOINT WIDTH.5.

SEALANT THICKNESS NO GREATER THAN 1/2".4.

SEALANT THICKNESS NO LESS THAN 1/4".3.

NO JOINT SEALANTS LARGER THAN 1".2.

NO JOINT SEALANTS SMALLER THAN 1/4".1.

SEALANT JOINT REQUIREMENTS:

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-001

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-002

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-003

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-004

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-005

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-006

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-007

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-008

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-009

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

REF-010

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

E

F E

R E

N C

E D

R A

W

IN

G

S P

IL

L W

A Y F

O U

N D

A T

IO

N P

IE

Z O

M E

T E

R R

E P

A

IR

S

G A

V

IN

S P

O

IN

T D

A M

D E

S

IG

N E

D B

Y

D E

S C

R

IP

T

IO

N

A

M A

R K

S

IZ

E

S U

B M

IT

T E

D B

Y

D A

T E

C O

N T

R A

C T N

O

C H

E C

K E

D B

Y

D R

A W

N B

Y

IS

S

U E D

A T

E

B

C

D

E

F

G

2 3 4 5 6 7 8 9 10

SHEET ID

®of Engineers

US Army Corps

U .S

A R

M Y C

O R

P S O

F E

N G

IN

E E

L

IC

IT

A T

IO

N N

O

W F -2

-Q

-0

J U

L Y

GP78G-001
GP78GI-001
GP78S-100
GP78S-500
GP78T-100
GP78T-500
GP78RCF01
GP78RCF02
GP78RCF03
GP78RCF04
GP78RCF05
GP78RCF06
GP78RCF07
GP78RCF08
GP78RCF09
GP78RCF10
GP78RCF11
GP78RCF12

File details come from the government source that posted it. Updated .