Am_0002_drawings.pdf
PDF 583 KB Posted
- Solicitation number
- W9128F-14-R-0052
About this file
Am0002
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Am_0002.pdf | ||
| site_visit_sign_in_sheet.pdf | ||
| Am_0001.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GENERAL FLOOR PLAN NOTES:
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND,
AND ABBREVIATIONS REFER TO SHEET A-001.
REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL
LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS
ARE CONTINUOUS ACROSS ALL DOOR OPENINGS.
FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION
REFER TO PARTITION TYPES SHEET.
THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS
AND SITE CONDITIONS BEFORE BEGINNING WORK AND
FABRICATION. THE OWNER SHALL BE NOTIFIED IN
WRITING IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES.
IN NO CASE SHALL DIMENSIONS BE SCALED OFF PLANS, SECTIONS,
OR DETAILS FROM THESE DRAWINGS.
FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,
REFER TO LARGER SCALE DRAWINGS.
DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE
OF GYPSUM BOARD FINISH WALL TO DOOR JAMB. VERIFY
THERE IS A PULL SIDE MINIMUM 18 INCHES CLEAR FROM DOOR
STRIKE TO INTERSECTING WALL FOR ADA COMPLIANCE. NOTIFY
OWNER FOR NON-COMPLIANCE BEFORE SETTING
DOOR FRAME AND WALL LOCATIONS.
PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING
IN WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT,
FLOOR AND WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP
MOUNTING SUPPORTS.
REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD
CONTROL JOINTS.
REFERENCE CIVIL DRAWINGS FOR EXTERIOR BOLLARD AND
SPLASH BLOCK DETAILS.
REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.
ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,
CENTER OF STUD OF METAL STUD WALL, UNLESS NOTED OTHERWISE.
THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS
NOTED OTHERWISE.
PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,
REFERENCE REFLECTED CEILING PLANS.
BACKER BOARD AT WALL MOUNTED ELECTRICAL AND CONTROL PANELS
SHALL BE FIRE TREATED PLYWOOD (TYP) COORDINATE WITH
ELECTRICAL AND COMMUNICATION SHEETS.
ALL FLOOR FINISHES TO BE SEALED CONCRETE, UNO.
ALL PARTITION WALLS TO RECEIVE PAINT AND 4" RUBBER BASE, UNO.
A
A-200
A1
A-200
A3
B C
C1 A-300
C1 A-300
A1 A-300
A1 A-300
MECHANICAL
ADMIN
CONTROL
ELECTRICAL
UNISEX RR
40' - 0"
20' - 0" 20' - 0"
10' - 0"
3'
- 4
0"
5'
- 0
0"
0"
0"
2' - 4" 6' - 4" 3' - 4" 12' - 8"
2"
101C
101B
1A
2A
A-200
C3
A-200
C1
2A
P2
P1
P2
P3P3
P4
P1
11' - 0"
4' - 0"
P2
P2
P1
P3
P5
P5
P5
P5
P1
P2
TYP
P3
P3
P5
P3
4' - 0"
P5
P8
1A
P2P2P2
1A
P7
P7
P7
TYP
TYP
P6
TYP
P6
TYP
P10P10
P9
P11P11
10"
P17
P16
2"
P14
P12
P13
P15P15
P13P13
P3
P18
P18P18
P18
P2 P2
ELECTRICAL
EQUIPMENT
D
ES
IG
N
ED
B
Y:
1 432
A
B
C
D
C O
PY
R
IG
H
T
B
U R
N S
M cD O
N N
EL
L
EN
G
IN
EE
R
IN
G C
O M
PA
N
Y, IN
C
SHEET
IDENTIFICATION
NUMBER
US ARMY CORPS
OF ENGINEERS
OMAHA DISTRICT
PN
U .S
. A R
M Y
EN
G
IN
EE
R D
IS
TR
IC
T
C O
R
PS
O F
EN
G
IN
EE
R S
O M
AH
A, N
EB
R
AS
KA
D
W N
B Y:
C
KD
B Y:
FI
LE
N
AM
E:
SI
ZE
PL
O T
SC
AL
E:
PL
O T
D
AT
E:
D
AT
E:
SU
BM
IT
TE
D B
Y:
C
O N
TR
AC
T N
O
FI
LE
N U
M
BE
R
X
SO
LI
C
IT
AT
IO
N N
O
F8
-1 7-
W
F-
-D
-0
AS
IN
D
IC
AT
ED
M
AY
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
W
F-
-R
-0
6/
/2
4:
:0
PM
A-101
(F
Y1 4)
4T H
ID
C
AB
, C
EN
TR
AL
E
N
ER
G Y
PL
AN
T
FL
O
O R
P
LA
N
FI
R
ST
F
LO
O R
J.
W
I E D
ER
H
O
LT J.
PI
C
KA
JW
BU
R
N S
M
C D
O N
N
EL
L
N
O R
M
AN
C
EN
TE
R
D R
BL
O O
M
IN
G
TO
N , M
N
2-
6-
FO
R
T C
AR
S O
N , C
O
LO
R A D
O
/2
6/
J.
W
IE
D
ER
H
O
LT
SCALE: 1/4" = 1'-0"A1 FLOOR PLAN
P1 CONCRETE STOOP, TYPICAL - SLOPE
AWAY FROM BUILDING AT 1/4" PER
FOOT
P2 CONCRETE FILLED STEEL BOLLARD
P3 FLOOR DRAIN, TYPICAL - SEE
MECHANICAL
P4 BACKER BOARD AT WALL MOUNTED
ELECTRICAL AND CONTROL PANELS TO
BE FIRE TREATED PLYWOOD, TYPICAL -
COORDINATE WITH ELECTRICAL &
COMMUNICATIONS
P5 STRUCTURAL BY PRE-ENGINEERED
METAL BUILDING MANUFACTURER, SEE
PEMB PLANS
P6 CONCRETE EQUIPMENT PAD (TYP) -
COORDINATE WITH EQUIPMENT SIZE
AND LOCATION
P7 MECHANICAL EQUIPMENT
P8 HOLLOW METAL WINDOW FRAME WITH
1/4" LAMINATED GLAZING
P9 FLOOR TRANSITION STRIP
P10 RUBBER FLOOR WITH 4" RUBBER BASE
THROUGHOUT
P11 CERAMIC FLOOR TILE THROUGHOUT
P12 MOP BASIN
P13 WALL MOUNTED LAVATORY, MIRROR
AND SOAP DISPENSER.
P14 PAPER TOWEL DISPENSER
P15 ADA COMPLIANT TOILET AND GRAB
BARS
P16 SOLID SURFACE COUNTER 30" AFF, SEE
C4/A-300
P17 SOLID SURFACE WORK SURFACE 42"
AFF, SEE C4/A-300
P18 2"X3" PRE-FINISHED METAL
DOWNSPOUT
N
0 2' 4' 8'
KEYNOTES
ROOM AREA SCHEDULE
ROOM NO. NAME AREA
101 MECHANICAL 1276 SF
102 ADMIN CONTROL 97 SF
103 UNISEX RR 60 SF
104 ELECTRICAL 91 SF
1523 SF
TOTAL GROSS SQUARE FOOTAGE 1701 SF
TOTAL NET SQUARE FOOTAGE
M
AR
K D
ES
C
R
IP
TI
O
N D
AT
E
AP
PR
PE
R
A M
EN
D
M
EN
T N
O . 0
/2
9/
APPENDIX C - RFP DRAWINGS
| Sheets |
| A-101 - FLOOR PLAN |
File details come from the government source that posted it. Updated .