GENERAL FLOOR PLAN NOTES:

1.

2.

3.

4.

5.

6.

7.

8.

9.

10.

11.

12.

13.

14.

15.

16.

FOR ARCHITECTURAL GENERAL NOTES, MATERIAL LEGEND,

AND ABBREVIATIONS REFER TO SHEET A-001.

REFERENCE LIFE SAFETY DRAWINGS FOR FIRE RATED WALL

LOCATIONS. ALL FIRE RATED WALLS AND SMOKE PARTITIONS

ARE CONTINUOUS ACROSS ALL DOOR OPENINGS.

FOR PARTITION TYPES CONSTRUCTION AND DESCRIPTION

REFER TO PARTITION TYPES SHEET.

THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS, ELEVATIONS

AND SITE CONDITIONS BEFORE BEGINNING WORK AND

FABRICATION. THE OWNER SHALL BE NOTIFIED IN

WRITING IMMEDIATELY OF ANY DISCREPANCIES OR INCONSISTENCIES.

IN NO CASE SHALL DIMENSIONS BE SCALED OFF PLANS, SECTIONS,

OR DETAILS FROM THESE DRAWINGS.

FOR DIMENSIONS OR ADDITIONAL INFORMATION NOT ILLUSTRATED,

REFER TO LARGER SCALE DRAWINGS.

DOOR LOCATIONS NOT DIMENSIONED ARE 4 INCHES FROM FACE

OF GYPSUM BOARD FINISH WALL TO DOOR JAMB. VERIFY

THERE IS A PULL SIDE MINIMUM 18 INCHES CLEAR FROM DOOR

STRIKE TO INTERSECTING WALL FOR ADA COMPLIANCE. NOTIFY

OWNER FOR NON-COMPLIANCE BEFORE SETTING

DOOR FRAME AND WALL LOCATIONS.

PROVIDE 18GA METAL PLATE OR FIRE TREATED WOOD BLOCKING

IN WALL FOR TOILET FIXTURES, ACCESSORIES, EQUIPMENT,

FLOOR AND WALL MOUNTED TOILET PARTITIONS, AND COUNTERTOP

MOUNTING SUPPORTS.

REFER TO SPECIFICATIONS FOR LOCATIONS OF GYPSUM BOARD

CONTROL JOINTS.

REFERENCE CIVIL DRAWINGS FOR EXTERIOR BOLLARD AND

SPLASH BLOCK DETAILS.

REFERENCE THE REFLECTED CEILING PLANS FOR CEILING HEIGHTS.

ALL DIMENSIONS ARE FROM: COLUMN GRID LINE, FACE OF CMU WALL,

CENTER OF STUD OF METAL STUD WALL, UNLESS NOTED OTHERWISE.

THE FIRST FLOOR FINISHED FLOOR ELEVATION IS 100'-0" UNLESS

NOTED OTHERWISE.

PROVIDE GYPSUM BOARD HEADER ABOVE ALL CASED OPENINGS,

REFERENCE REFLECTED CEILING PLANS.

BACKER BOARD AT WALL MOUNTED ELECTRICAL AND CONTROL PANELS

SHALL BE FIRE TREATED PLYWOOD (TYP) COORDINATE WITH

ELECTRICAL AND COMMUNICATION SHEETS.

ALL FLOOR FINISHES TO BE SEALED CONCRETE, UNO.

ALL PARTITION WALLS TO RECEIVE PAINT AND 4" RUBBER BASE, UNO.

A

A-200

A1

A-200

A3

B C

C1 A-300

C1 A-300

A1 A-300

A1 A-300

MECHANICAL

ADMIN

CONTROL

ELECTRICAL

UNISEX RR

40' - 0"

20' - 0" 20' - 0"

10' - 0"

3'

- 4

0"

5'

- 0

0"

0"

0"

2' - 4" 6' - 4" 3' - 4" 12' - 8"

2"

101C

101B

1A

2A

A-200

C3

A-200

C1

2A

P2

P1

P2

P3P3

P4

P1

11' - 0"

4' - 0"

P2

P2

P1

P3

P5

P5

P5

P5

P1

P2

TYP

P3

P3

P5

P3

4' - 0"

P5

P8

1A

P2P2P2

1A

P7

P7

P7

TYP

TYP

P6

TYP

P6

TYP

P10P10

P9

P11P11

10"

P17

P16

2"

P14

P12

P13

P15P15

P13P13

P3

P18

P18P18

P18

P2 P2

ELECTRICAL

EQUIPMENT

D

ES

IG

N

ED

B

Y:

1 432

A

B

C

D

C O

PY

R

IG

H

T

B

U R

N S

M cD O

N N

EL

L

EN

G

IN

EE

R

IN

G C

O M

PA

N

Y, IN

C

SHEET

IDENTIFICATION

NUMBER

US ARMY CORPS

OF ENGINEERS

OMAHA DISTRICT

PN

U .S

. A R

M Y

EN

G

IN

EE

R D

IS

TR

IC

T

C O

R

PS

O F

EN

G

IN

EE

R S

O M

AH

A, N

EB

R

AS

KA

D

W N

B Y:

C

KD

B Y:

FI

LE

N

AM

E:

SI

ZE

PL

O T

SC

AL

E:

PL

O T

D

AT

E:

D

AT

E:

SU

BM

IT

TE

D B

Y:

C

O N

TR

AC

T N

O

FI

LE

N U

M

BE

R

X

SO

LI

C

IT

AT

IO

N N

O

F8

-1 7-

W

F-

-D

-0

AS

IN

D

IC

AT

ED

M

AY

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

W

F-

-R

-0

6/

/2

4:

:0

PM

A-101

(F

Y1 4)

4T H

ID

C

AB

, C

EN

TR

AL

E

N

ER

G Y

PL

AN

T

FL

O

O R

P

LA

N

FI

R

ST

F

LO

O R

J.

W

I E D

ER

H

O

LT J.

PI

C

KA

JW

BU

R

N S

M

C D

O N

N

EL

L

N

O R

M

AN

C

EN

TE

R

D R

BL

O O

M

IN

G

TO

N , M

N

2-

6-

FO

R

T C

AR

S O

N , C

O

LO

R A D

O

/2

6/

J.

W

IE

D

ER

H

O

LT

SCALE: 1/4" = 1'-0"A1 FLOOR PLAN

P1 CONCRETE STOOP, TYPICAL - SLOPE

AWAY FROM BUILDING AT 1/4" PER

FOOT

P2 CONCRETE FILLED STEEL BOLLARD

P3 FLOOR DRAIN, TYPICAL - SEE

MECHANICAL

P4 BACKER BOARD AT WALL MOUNTED

ELECTRICAL AND CONTROL PANELS TO

BE FIRE TREATED PLYWOOD, TYPICAL -

COORDINATE WITH ELECTRICAL &

COMMUNICATIONS

P5 STRUCTURAL BY PRE-ENGINEERED

METAL BUILDING MANUFACTURER, SEE

PEMB PLANS

P6 CONCRETE EQUIPMENT PAD (TYP) -

COORDINATE WITH EQUIPMENT SIZE

AND LOCATION

P7 MECHANICAL EQUIPMENT

P8 HOLLOW METAL WINDOW FRAME WITH

1/4" LAMINATED GLAZING

P9 FLOOR TRANSITION STRIP

P10 RUBBER FLOOR WITH 4" RUBBER BASE

THROUGHOUT

P11 CERAMIC FLOOR TILE THROUGHOUT

P12 MOP BASIN

P13 WALL MOUNTED LAVATORY, MIRROR

AND SOAP DISPENSER.

P14 PAPER TOWEL DISPENSER

P15 ADA COMPLIANT TOILET AND GRAB

BARS

P16 SOLID SURFACE COUNTER 30" AFF, SEE

C4/A-300

P17 SOLID SURFACE WORK SURFACE 42"

AFF, SEE C4/A-300

P18 2"X3" PRE-FINISHED METAL

DOWNSPOUT

N

0 2' 4' 8'

KEYNOTES

ROOM AREA SCHEDULE

ROOM NO. NAME AREA

101 MECHANICAL 1276 SF

102 ADMIN CONTROL 97 SF

103 UNISEX RR 60 SF

104 ELECTRICAL 91 SF

1523 SF

TOTAL GROSS SQUARE FOOTAGE 1701 SF

TOTAL NET SQUARE FOOTAGE

M

AR

K D

ES

C

R

IP

TI

O

N D

AT

E

AP

PR

PE

R

A M

EN

D

M

EN

T N

O . 0

/2

9/

APPENDIX C - RFP DRAWINGS

Sheets
A-101 - FLOOR PLAN

File details come from the government source that posted it. Updated .