PROPERLY FIRE STOP ALL PENETRATIONS THROUGH FIRE RATED WALLS,
FLOORS, OR PARTITIONS WITH A UL APPROVED SYSTEM APPROPRIATE
FOR THE PENETRATION TYPE AND FIRE RATING IN ACCORDANCE WITH
MANUFACTURER'S INSTALLATION INSTRUCTIONS.
16.
14.
DRAWINGS DO NOT ATTEMPT TO SHOW EXACT DETAILS OF PIPING.
PROVIDE OFFSETS AS NECESSARY TO AVOID LOCAL OBSTRUCTIONS OR
INTERFERENCE WITH OTHER TRADES AND EXISTING OBSTRUCTIONS.
REVIEW ALL PIPING RUNS PRIOR TO FABRICATION AND IMMEDIATELY
NOTIFY THE CONTRACTING OFFICER OF ANY INTERFERENCE AND/OR LACK
OF ADEQUATE CLEARANCES.
10.
12.
PATCH AND PAINT ALL EXPOSED MATERIAL INCLUDING PIPING, TO MATCH
ADJACENT SURFACES WHERE INDICATED.
SEISMICALLY BRACE ALL EQUIPMENT AND PIPING AS INDICATED. BRACE
SYSTEMS IN ACCORDANCE WITH SMACNA STDS.
7. VERIFY THE EXACT LOCATION , SIZE, AND INVERT OF ALL EXISTING, AND
WATER LINES AT THE POINT OF CONNECTION PRIOR TO THE START OF
CONSTRUCTION.
17. CONTRACTOR SHALL PROVIDE COPPER LABELS INDICATING TYPE AND
DIRECTIONAL FLOW TO THE PIPING.
PLUMBING CONTRACTOR SHALL COORDINATE ALL FLOOR CUTTING AND
PATCHING WORK TO INSTALL NEW PIPING.
8.
9.
REPAIR ANY DAMAGE TO EXISTING CONSTRUCTION RESULTING FROM THE
INSTALLATION OF PLUMBING ITEMS. THE AREAS REPAIRED SHALL MATCH
THE ADJACENT SURFACES IN TEXTURE AND COLOR.
13.
THE ENTIRE INSTALLATION SHALL COMPLY WITH ALL APPLICABLE
REQUIREMENTS OF THE LATEST EDITION OF THE NATIONAL ELECTRICAL
CODE, INTERNATIONAL PLUMBING CODE-2012, UFC 3-420-01 PLUMBING
SYSTEMS WITH CHANGE 7, EPACT 2005, ASHRAE 90.1-2007, ASHRAE
189.1-2009 AND ALL OTHER LOCAL AGENCIES HAVING JURISDICTION. THE
INSTALLATION SHALL FURTHER COMPLY WITH THE ORIGINAL CONTRACT
SPECIFICATIONS FOR MATERIAL, AND INSTALLATION SPECIFICATIONS OF
PLUMBING, FIRE PROTECTION, AND MECHANICAL WORK.
1.
PLUMBING GENERAL NOTES:
ALL EQUIPMENT SHALL BE CAPABLE OF FITTING INTO THE SPACES
ALLOCATED WHILE MEETING THE MANUFACTURER'S RECOMMENDED
ACCESS REQUIREMENTS. REVIEW ALL SPACES WHERE EQUIPMENT IS TO
BE INSTALLED PRIOR TO ORDERING OF EQUIPMENT AND NOTIFY THE
CONTRACTING OFFICER OF ANY INADEQUATE CLEARANCES OR
CONDITIONS THAT WILL PREVENT THE PROPER INSTALLATION,
MAINTENANCE, AND OPERATION OF THE EQUIPMENT.
THE DRAWINGS AND SPECIFICATIONS ARE INTENDED TO COVER THE
COMPLETE INSTALLATION OF SYSTEMS TO FUNCTION AS DESCRIBED AND
SPECIFIED. THE OMISSION OF REFERENCE TO ANY NECESSARY ITEM OF
LABOR OR MATERIAL SHALL NOT RELIEVE THE CONTRACTOR FROM
PROVIDING SUCH LABOR AND MATERIAL.
2.
COORDINATE WITH OTHER TRADES PRIOR TO COMMENCING AND DURING
CONSTRUCTION. OVERLAY PLANS AND CHECK FOR ANY DISCREPANCIES
OR CONFLICTS WITH OTHER TRADES.
VERIFY AND COORDINATE ALL WALL AND FLOOR PENETRATIONS WITH THE
ARCHITECTURAL DRAWINGS AND NOTIFY THE CONTRACTING OFFICER OF
ANY CONFLICTS PRIOR TO START OF CONSTRUCTION.
OBTAIN APPROVAL FROM THE CONTRACTING OFFICER BEFORE MAKING
ANY PENETRATIONS THROUGH STRUCTURAL MEMBERS, WALLS AND
SLABS.
6.
5.
4.
ALL EXPOSED PIPING IN FINISHED AREAS SHALL BE CHROME PLATED OR
COPPER.
3.
SHOULD PROJECT CONDITIONS REQUIRE REARRANGEMENT OF WORK,
MARK SUCH CHANGES ON THE AS-BUILT DRAWINGS AND NOTIFY THE
CONTRACTING OFFICER. IF THESE CHANGES REQUIRE ALTERNATE
METHODS TO THOSE APPROVED BY THE CONTRACT DOCUMENTS, SUBMIT
SHOP DRAWINGS SHOWING THE PROPOSED ALTERNATE METHODS TO THE
CONTRACTING OFFICER FOR REVIEW. DO NOT PROCEED UNTIL REVIEWED.
11.
GV GATE VALVE
S OR W SOIL OR WASTE
FD FLOOR DRAIN
PLUMBING LEGEND
SYMBOL
TYP TYPICAL
REQ'D REQUIRED
CW
CV
COLD WATER
CHECK VALVE
CLN'G
CEILING
ABOVE FINISHED FLOOR
AFF
ABBRV. DESCRIPTION
VENT THRU ROOF
VENT
VTR
V
BV BALL VALVE
POINT OF REMOVALPOR
POINT OF CONNECTIONPOC
UNION
U/G UNDER GROUND
LAVATORYLAV
HOSE BIBBHB
SK SINK
RPBP REDUCED PRESSURE BACKFLOW PREVENTER
JANITOR SINKJS
KITCHEN SINKKS
PRESSURE REDUCING VALVE
BALANCING VALVE
CONTINUATIONCONT.
DOWNDN
FLOOR SINKFSK
MIXING VALVEMV
PRESSURE GAUGE
STRAINER
DIRECT DIGITAL CONTROLDDC
BUILDINGBLDG
NORMALLY CLOSEDN.C.
WHERE OCCURSW.O.
P-001
P L U
M B
I N
G
G
E N
E R
A L
N
O T
E S
L E
G E
N D
A
N D
S
Y M
B O
L S
PROGRAMMABLE LOGIC CONTROLLERPLC
TOTAL ENCLOSED FAN COOLEDTEFC
DIRECT DIGITAL CONTROLDDC
T
H
T
G
A
R M
Y
R
E S
E R
V E
F
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
P
X X
X
(EXIST.)
(EXIST.)
(EXIST.)
(EXIST.)
(EXIST.)
(EXIST.)
(EXIST.)
MAINTENANCE
LOADING
AREA
FH
FOR MECH RM PLANS,
SEE SHT. P-101
REPLACE EXISTING
BACKFLOW PREVENTER,
VALVES, AND ELBOWS. SEE
SHEET P-501 DETAIL C4
4" CW
EXIST. 4" CW SERVICE,
SEE AS-101 FOR CONT.
EXCAVATE AREA TO
ACCESS EXIST. 4" PIPING.
REMOVE SECTION & CAP
SCALE: 1/16" = 1'-0"
0 16' 32'8'
SCALE: 1/16"=1'-0"
PLUMBING SITE PLAN
A3
PS101
P L U
M B
I N
G
S
I T
E
P
L A
N
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
P S
X
X
AHU
AHU
EXISTING
EXISTING
HB
HB
EXISTING 2" CW PIPING TO REMAIN
2"
EXISTING COMPRESSOR
EXISTING PIPING BELOW SLAB
TO REMAIN
AHU
AHU
EXISTING
EXISTING
HB
HB
BP
BP
4" BY-PASS
2"
POC
4"
4"
PUMP CONTROL PANEL
VFD
EXISTING FIRE SERVICE RISER
EXISTING COMPRESSOR
POC
EXISTING ROUTE CW PIPING
U/G TO REMAIN
EXISTING ROUTE PIPING BELOW
SLAB TO REMAIN
OFFICE
MECHANICAL ROOM
169 170
OFFICE
SHOP
OFFICE
SHOP
OFFICE
SHOP
MAINTENANCE
OFFICE
MECHANICAL ROOM
169 170
OFFICE
SHOP
OFFICE
SHOP
OFFICE
SHOP
MAINTENANCE
B
B.0.1
B.1
B.2
B
B.0.1
B.1
B.2
TO REMAIN
REMOVE EXISTING 4" CW PIPING RISER SECTION
FOR CONNECTION TO NEW BP-1/2 SKID
SEE SHEET P-101 DETAIL A3
21.9 3
REMOVE EXISTING 4" VALVE, 4"x2"
REDUCER, AND 2" PIPING APPROXIMATELY
12" ABOVE THE 4" VALVE
REMOVE PIPE SECTION
CUT ASPHALT & TRENCH TO EXPOSE
EXIST. PIPING
EXIST. 4" (U/G)
EXIST. 4" (U/G)
POR & CAP EACH SIDE
EXIST. DUCTWORK
ABOVE
EXIST. FIRE SPRINKLER SUPPLY
PIPING RISER
EXIST. CHW PIPING
21.9 3
DUCTWORK
ABOVE
MAINTAIN 36" WORKING
CLEARANCE IN FRONT OF VFD'S
LOCATE NEW BOOSTER
PUMP SKID ADJACENT TO
EXIST. AHU-9
ROUTE PURGE DRAWIN TO
EAST FLOOR SINK BELOW
PATCH & BACKFILL AREA
TO MATCH EXIST.
NEW 2" CW DOWN
TO POC
POC NEW 2" TO
4" RISER WITH
4"x4"x4" TEE
ROUTE NEW 4" PIPING CLEAR
OF AHU-9, SEE B4/P-501 FOR
SUPPORT DETAIL
EXIST. 4" (U/G)
SCALE: 1/4" = 1'-0"
0 4' 8'2'
SCALE: 1/4"=1'-0"
MECHANICAL ROOM REMOVAL WORK
C3
SCALE: 1/4"=1'-0"
MECHANICAL ROOM NEW WORK
A3 P-101
M E
C H
A N
I C
A L
R
O O
M
R
E M
O V
A L
A N
D
N
W
W
O R
K
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
P
X X
X
NEW 2" CW PIPING
IN CEILING
AFF
0'-0"
ROOF
AFF
0'-0"
ROOF
POR
POR
POR
REMOVE EXISTING 4" CW PIPE RISER
EXISTING 4" CW PIPE
EXISTING 4" UNDERGROUND CW PIPE TO REMAIN
EXISTING 2" CW PIPE
EXISTING 4" CW PIPE
EXISTING 4" UNDERGROUND CW PIPE TO REMAIN
POR
REMOVE 4"x2"
REMOVE 4" BV
EXIST. 4" FLANGE
CAP 4" PIPINGCAP 4" PIPING
REMOVE U/G
PIPING SECTION
2" PIPING
POR
POR
EXIST. 2" PIPING
TO REMAIN
PORPOR
REMOVE EXIST.
ELBOWS
REMOVE EXIST.
RPBFP AND VALVES
POR
POR
REMOVE EXIST.
4" PIPE SECTION
REMOVE 2" PIPE
UP TO POR
SEE A3/P-501
FOR PIPE CAP
DETAIL
SCALE: 1/4" = 1'-0"
0 4' 8'2'
NOT TO SCALE
PIPING ELEVETION B-B REMOVAL WORK
C2
NOT TO SCALE
PIPING ELEVATION A-A REMOVAL WORK
A2
P-201
P I P
I N
G
R
I S
I A
G R
A M
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
P
X X
MECH ROOMMAINTENANCE BAY
AFF
0'-0"
ROOF
AFF
0'-0"
ROOF
20"
TYP.
2" SHIM
10"
2'-4"
2'-4"
12"
4'-0"
10"
5'-6" O.A.H.
FLOW
POR/POC
POR/POC
POR/POC
POC
NEW 2" CW PIPE
NEW 2" CW PIPE RISER
RE-CONNECT EXISTING 4" CW
PIPE RISER TO BOOSTER PUMP
FLOW
SKID MOUNTED BOOSTER PUMP
EXISTING 4" CW PIPE
NEW 2" CW PIPE
EXISTING 4" UNDERGROUND CW PIPE TO REMAIN
EXISTING 4" CW PIPE TO REMAIN
EXISTING 4" UNDERGROUND CW PIPE TO REMAIN
POR/POC
FLOW
4"
4"
BP
BP
NOTES:
1. ALL DIMENSIONS SUBJECT TO CHANGE PER SELECTED PUMP
MANUFACTURER
2. PURGE VALVE DRAIN LINE TO BE PIPED BY CONTRACTOR TO FLOOR
DRAIN ADJACENT TO EXIST. AHU-9
3. PIPING CONNECTIONS SHALL BE IN ACCORDANCE WITH PUMP
MANUFACTURER'S REQUIREMENTS
POC
REPLACE VALVES & 90°
ELBOWS ON EACH SIDE
OF THE RPBFP
REPLACE EXISTING 4"
BACKFLOW PREVENTER
ON EXTERIOR OF BLDG.
POC
POC
CAP
4"x4"x4" TEE
4" ELBOW
4"x 2"
2" BV
NEW 2" PIPINGEXISTING 2" COPPER
2" BV
4"x 2"
POC
4"x4"x4" TEE
4" ELBOW
4"x 2"
2" BV
NEW 2" PIPING
2" BV
4"x 2"
POC
EXIST. 2" PIPING
EXIST. U/G PIPING TO
PARKING GARAGE
SCALE: 1/4" = 1'-0"
0 4' 8'2'
NOT TO SCALE
PIPING ELEVETION B-B NEW WORK
C3
NOT TO SCALE
PIPING ELEVATION A-A NEW WORK
A3
P-202
P I P
I N
G
R
I S
A
G R
A M
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
P
X X
MECH ROOMMAINTENANCE BAY
COLUMN A: STD. WT. STEEL PIPE
& CAST IRON PIPE
3/8
A
PIPE SIZE
1/2-2
SOURCE: MSS STANDARD SP-69
CLEVIS TYPE HANGER
THREADED HANGER ROD
PIPE SLEEVE W/ ID 8
INCH LARGER THAN
OD OF BOLT
PIPE
PIPE STRAP
CMU WALL OR COLUMN
EXIST. CONCRETE WALL
SECTION A-A
2" GALV. STEEL
1.5 x 1.5 x 0.5 GALV.
ANGLE, PAINT TO
MATCH ADJACENT
SURFACE, TYP.
(INCH)
PROVIDE DIELECTRIC
TAPE AT EACH PIPE
CLAMP
NOMINAL ROD
DIAMETER (INCH)
1 HR. RATED
FIRE STUD
WALL
MIN.
L
C
NOT TO SCALE
PIPE HANGER DETAIL
C1
NOT TO SCALE
PIPE THRU STUD WALL DETAIL
C3
NOT TO SCALE
BACK FLOW PREVENTER DETAIL
C4
NOT TO SCALE
PIPE SUPPORT DETAIL WALL MOUNTED
A1
NOT TO SCALE
PIPE THRU INTERIOR MASONARY WALL DETAIL
B2
P-501
P L U
M B
I N
G
D
E T
A I L S
POC/POR
ESCUTCHEON AT
FINISHED WALLS
P
X X
X
POR/POC
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
NOTES:
1. REDUCED PRESSURE BACKFLOW PREVENTER SHALL BE LEAD
FREE AND USC APPROVED.
2. MODIFY PIPING AND PROVIDE ADDITIONAL FITTINGS AS
NECESSARY TO ACCOMMODATE TOTAL LENGTH OF BACKFLOW
PREVENTION ASSEMBLY WITHIN EXISTING FLANGE TO FLANGE
DIMENSIONS.
3. PAINT ENTIRE ASSEMBLY FOR CORROSION PROTECTION.
EXIST. 4" RISER PIPING
TO REMAIN (TYP.)
EXIST. TIE RODS TO
REMAIN
EXIST. RISER TO
REMAIN
9"
(MAX)
37"
(MAX)
9"
(MAX)
NEW
RPBFP
NOT TO SCALE
DUCTILE IRON CAP DETAIL
A3
TYPE 24 U-BOLT
TYPE 40 PROTECTION SHIELD
TYPE 39 SADDLE WELDED
PIPE, GALVANIZED
1 1/2" DIA. STD. WT. STEEL
ANGLE, GALVANIZED
1/4"
V A
R I E
S
TO PIPE
2 X 2 X 1/4"
WATER PIPE (4" DIA.)
1/2" ANCHOR
BOLTS
CONC. FLOOR
1/2"
NOT TO SCALE
PIPE SUPPORT STAND
B4
PIPE FLANGE, GALVANIZED
OR 1/4" THICK STEEL PLATE
ELECTRICAL MOTOR
HZPH
V
BOOSTER PUMP SCHEDULE
UNIT
FLOW
HP
(GPM)
BP-1 140 7.5 208 3 60
REMARKS
PROVIDE WITH TEFC PREMIUM EFFICIENCY MOTOR.95
FLA
PUMP TYPE
CLOSE COUPLED END SUCTION
DYNAMIC
HEAD
BP-2 208 3 60 PROVIDE WITH TEFC PREMIUM EFFICIENCY MOTOR.28CLOSE COUPLED END SUCTION
SEQUENCE OF OPERATION:
A. GENERAL ITEMS APPLYING TO EACH ALARM CIRCUIT SHALL INCLUDE A DISPLAY OF CONDITION, THE
ILLUMINATION OF A RED INDICATING LIGHT, AND MANUAL OR AUTOMATIC RESET OF CONDITION. ONLY
ONE PUMP SHALL OPERATE AT A TIME.
B. ALARM SEQUENCE
1. LOW SUCTION PRESSURE ALARM. LOW SUCTION PRESSURE ALARM SHALL PROTECT THE PUMPS FROM
OPERATING WITHOUT ADEQUATE INLET PRESSURE, WHICH COULD CAUSE DAMAGE TO PUMPS. A
PRESSURE SENSOR SHALL BE MONITOR PRESSURE AT THE SUCTION MANIFOLD. THIS FEATURE SHALL
INCLUDE A SHORT TIME DELAY TO HANDLE TRANSIENT CONDITIONS WHICH CAN OCCUR DURING THE
STARTING OF A PUMP. OPERATOR INTERFACE DEVICE (OIT), MOUNTED IN ENCLOSURE DOOR, SHALL
SIGNAL LOW SUCTION PRESSURE. PUMP SYSTEM SHALL NOT START UNTIL LOW SUCTION PRESSURE IS
CORRECTED AND CIRCUIT HAS BEEN RESET. ALARM SHALL BE EQUIPPED WITH VISUAL INDICATION AND
AUTOMATIC RESET.
2. HIGH DISCHARGE PRESSURE ALARM. HIGH DISCHARGE PRESSURE ALARM CIRCUIT SHALL SHUT DOWN
PUMPING SYSTEM IF DISCHARGE PRESSURE REACHES A PREDETERMINED HIGH LEVEL. OPERATOR
INTERFACE DEVICE (OIT), MOUNTED IN ENCLOSURE DOOR, SHALL SIGNAL HIGH DISCHARGE PRESSURE.
PUMPING SYSTEM SHALL NOT OPERATE UNTIL PRESSURE IS REDUCED AND ALARM HAS BEEN RESET.
ALARM SHALL BE EQUIPPED WITH VISUAL INDICATION AND AUTOMATIC RESET.
3. LOW DISCHARGE PRESSURE ALARM. LOW DISCHARGE PRESSURE ALARM CIRCUIT SHALL SHUT DOWN
PUMPING SYSTEM IN THE EVENT DISCHARGE PRESSURE DROPS BELOW NORMAL LEVEL. OPERATOR
INTERFACE DEVICE (OIT), MOUNTED IN ENCLOSURE DOOR, SHALL SIGNAL LOW DISCHARGE PRESSURE.
PUMPING SYSTEM SHALL NOT OPERATE UNTIL ALARM HAS BEEN MANUALLY RESET. ALARM SHALL BE
EQUIPPED WITH VISUAL INDICATION AND MANUAL OVERRIDE.
4. MAIN PHASE FAILURE AND LOW VOLTAGE SAFETY CIRCUIT SHALL RETIRE THE PUMPING SYSTEM IF IT
EXPERIENCES LOW VOLTAGE, PHASE FAILURE OR PHASE REVERSAL AS MONITORED AT LINE-SIDE OF
CONTROL ENCLOSURE. PHASE MONITOR SHALL HAVE A TIME DELAY TO ALLOW FOR TRANSIENT LOW
VOLTAGE DURING MOTOR STARTING AND TO ALLOW MAXIMUM MOTOR PROTECTION OPERATOR
INTERFACE DEVICE (OIT), MOUNTED IN ENCLOSURE DOOR, SHALL SIGNAL PHASE FAILURE FOR ANY
AFFECTED PUMP.
5. SYSTEM THERMAL PURGE. THERMAL PURGE SHALL INCLUDE A TEMPERATURE SENSOR AND VALVE FOR
EACH PUMP. THERMAL SENSOR SHALL OPEN THE SOLENOID VALVE WHEN IT EXPERIENCES A WATER
TEMPERATURE IN EXCESS OF 140°F. VALVE SHALL BE A 1/4" BRASS TWO WAY VALVE. VALVE, WHEN ACTUATED, SHALL PURGE WATER FROM THE PUMP DISCHARGE, TO ATMOSPHERE. A 1/2" LINE
TO DRAIN SHALL BE PROVIDED ON SITE BY THE INSTALLING CONTRACTOR. THERMAL PURGE SHALL NOT
BE CONSIDERED AS AN ALARM, BUT ITS FUNCTION SHALL BE CONSIDERED AS NORMAL OPERATION.
THERE SHALL BE NO INDICATION OF ITS OPERATION, OTHER THAN WARM WATER DISCHARGE, AND IT
SHALL NOT SHUT DOWN ANY PUMPS.
6. PUMP OR VFD FAILURE ALARM. PUMP OR VFD FAILURE ALARM CIRCUIT SHALL SHUT DOWN ITS INDIVIDUAL
PUMP AND VFD IF THE VFD DETECTS AN OVERLOAD CONDITION OR IF THE VFD EXPERIENCES AN
INTERNAL FAULT. ALARM SHALL BE EQUIPPED WITH VISUAL INDICATION.
7. PUMP FAILURE ALARM. PUMP FAILURE ALARM CIRCUIT SHALL SHUT DOWN ITS INDIVIDUAL PUMP IF THE
PUMP FAILS TO RAISE ITS DISCHARGE PRESSURE ABOVE ITS DISCHARGE PRESSURE SWITCH SETTING
WITHIN A PREDETERMINED TIME AFTER THE MOTOR HAS BEEN STARTED, OR IF THE PUMP DISCHARGE
PRESSURE DROPS BELOW ITS DISCHARGE PRESSURE SWITCH SETTING WHILE IT IS RUNNING.
OPERATOR INTERFACE DEVICE (OIT), MOUNTED IN ENCLOSURE DOOR, SHALL SIGNAL PUMP FAILURE.
AFFECTED PUMP SHALL NOT OPERATE UNTIL ALARM HAS BEEN RESET MANUALLY. CIRCUIT SHALL
INCLUDE A PRESSURE SWITCH SENSING PUMP DISCHARGE PRESSURE, TIMER, RELAY, MANUAL RESET, AND INDICATION OF CONDITION. ALARM SHALL BE EQUIPPED WITH VISUAL INDICATION.
C. FUNCTIONAL SEQUENCE, PRESSURE AND FLOW SEQUENCING
1. EQUAL SIZED PUMPS SHALL BE ALTERNATED BASED ON ACCUMULATED RUN TIME, THE PUMP HAVING
THE LEAST RUN TIME STARTING AS LEAD. ONLY ONE PUMP SHALL RUN AT A TIME.
2. IN THE EVENT A PUMP HAS FAILED TO RUN OR START, OR IF ITS SWITCH IS TURNED OFF, PLC SHALL
SHIFT THE PUMPING SEQUENCE TO UTILIZE THE REMAINING PUMPS.
3. LEAD PUMP SHALL START IMMEDIATELY ON A REDUCTION IN DISCHARGE PRESSURE (35 PSI FACTORY
DEFAULT VALUE).
4. PLC SHALL CONTROL PUMP'S VFD TO MAINTAIN DISCHARGE PRESSURE REGARDLESS OF FLOW RATE.
5. LEAD PUMP SHALL RETIRE WHEN FLOW HAS DECREASED TO ZERO AS MAINTAINED FOR A TIME (30-45
SECONDS DEFAULT VALUE).
SCADA INTERFACE (FUTURE)
1. SUCTION PRESSURE (AO)
2. DISCHARGE PRESSURE (AO)
3. FLOW RATE (AO)
1. EACH PUMP CALL (DI)
2. EACH PUMP RUNNING (DO)
3. EACH PUMP FAULT (DO)
4. GENERAL ALARM (DO)
BYPASS
SWITCH
208,3Ø,60HZ
H-O-A
SWITCH
STARTER
TO PRESSURE
SENSOR
DDC
CONTACT
PUMP
MOTOR
TOTAL
140 7.595
NOT TO SCALE
PUMP W/VFD CONTROL DIAGRAM
B3
P-601
S E
Q U
E N
C
O
P E
R A
T I O
N
E
Q U
I P
M E
N T
S C
H E
D U
L E
A
N
T R
O L
D
I A
G R
A M
(FT)
RPM
BHP
5.4
5.4
NPSHR
(FT)
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
P
X X
X
NOTE:
1. PROVIDE VFD W/ BYPASS CONTROLLER AND 5% LINE
REACTOR.
2. TYPICAL FOR EACH SKID MOUNTED PUMP
1. THE BOOSTER PUMP SHALL HAVE THE FOLLOWING OUTPUT
FOR SCADA MONITORING (FUTURE):
2. PROVIDE AUXILIARY CONTACTS FOR INTERFACE WITH A
FUTURE SCADA OR DDC SYSTEM:
NOT TO SCALE
PIPING RISER ISOMETRIC DIAGRAM
A2
P-901
P I P
I N
G
R
I S
O M
E T
R
A
G R
A M
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
P
X X
X
BUILDING
PENETRATION
ABOVE FINISHED
GRADE
POC TO CIVIL
CONNECTION
EXISTING PIPNG
BELOW GRADE
EXISTING PIPING BELOW GRADE
NEW 2" CW
REMOVE EXISTING
4" CW PIPING
MAIN CW
SHUT-OFF VALVE IN
MECH/CUS RM
ROUTE PIPING IN
CEILING SPACE
FLOOR
PENETRATION,
TYP.
POC
POC
POC
ROUTE PIPING
BELOW GRADE
TO WATER TANK
4"x4"x4" TEE
2" BV
4"x2"
POC
2" BV
4"x2"
POC TO
EXIST. 4"
EXIST. 2"
COPPER PIPING
EXIST. 4" DUCTILE
IRON PIPING
EXIST. U/G DUCTILE
IRON PIPING
NEW COPPER
PIPING (TYPE L)
NEW REDUCED PRESSURE
BACKFLOW PREVENTER
GENERAL NOTES
1. PERFORM ELECTRICAL WORK IN ACCORDANCE WITH THE LATEST EDITION OF THE
NATIONAL ELECTRICAL CODE (NFPA 70), NATIONAL ELECTRICAL SAFETY CODE, UNIFORM
BUILDING CODE, UNIFORM FIRE CODE, NATIONAL FIRE PROTECTION CODE (NFPA 101),
FAA-C-1391b, FAA-STD-019c, AND OTHER FAA SPECIFICATIONS WHERE REFERENCED IN
THESE PLANS AND SPECIFICATIONS, AND ALL LOCAL RULES AND REGULATIONS.
2. PROVIDE AN INSULATED GREEN GROUNDING CONDUCTOR, SIZED PER TABLE 250-95 OF
THE NATIONAL ELECTRICAL CODE, FOR ALL CIRCUITS. INSTALL THIS CONDUCTOR IN ALL
RACEWAYS INCLUDING THOSE INSTALLED FOR SWITCH LEGS AND ATTACH TO THE
DEVICE, LUMINAIRE, OR EQUIPMENT USING A SUITABLE GROUNDING LUG.
3. PROVIDE AND INSTALL ALL JUNCTION AND PULLBOXES REQUIRED FOR THE
INSTALLATION OF ELECTRICAL DEVICES AND EQUIPMENT, WHETHER OR NOT
SPECIFICALLY INDICATED ON THE PLANS. SIZE BOXES PER THE NATIONAL ELECTRICAL
CODE.
4. COORDINATE WITH OTHER TRADES AND CONFIRM THE EXACT EQUIPMENT LOCATIONS
AND THE LOCATIONS AND MOUNTING HEIGHTS OF ALL POWER AND TELEPHONE DEVICES
BEFORE ROUGHING IN.
5. SEAL ALL PENETRATIONS THROUGH FIRE RATED WALLS AND SLABS USING A U.L. LISTED
FIRE RATED SEALANT TO MAINTAIN THE INTEGRITY OF THE FIRE RATING.
6. SEAL AND PAINT ALL PENETRATIONS THROUGH WALLS AND SLABS TO MATCH ADJACENT
SURFACE.
7. OBTAIN APPROVAL FROM THE CONTRACTING OFFICER/ OFFICER IN CHARGE, BEFORE
MAKING ANY PENETRATIONS THROUGH STRUCTURAL MEMBERS OR FIRE RATED WALLS
AND SLABS.
8. CONFIRM THE TYPE OF CEILING BEING INSTALLED PRIOR TO ORDERING LUMINAIRE
TRIMS FOR PROPER COORDINATION. CATALOG NUMBERS ARE GIVEN FOR A GENERIC
LUMINAIRE AND MAY NOT EXPRESSLY CONFIRM TYPE OF CEILING OR OPENING
PROVIDED BY OTHER TRADES.
9. ALL EQUIPMENT SHALL BE CAPABLE OF FITTING IN THE SPACES LOCATED WHILE
MEETING THE MANUFACTURER'S RECOMMENDED ACCESS REQUIREMENTS. REVIEW ALL
PLACES WHERE EQUIPMENT IS TO BE INSTALLED PRIOR TO ORDERING OF EQUIPMENT
AND NOTIFY THE CONTRACTING OFFICER OF ANY INADEQUATE CLEARANCES OR
CONDITIONS THAT WILL PREVENT THE PROPER INSTALLATION, MAINTENANCE, AND
OPERATIONS OF THE EQUIPMENT.
10. COORDINATE WITH OTHER TRADES PRIOR TO COMMENCING AND DURING
CONSTRUCTION. OVERLAY PLANS AND CHECK FOR ANY DISCREPANCIES OR CONFLICTS
WITH OTHER TRADES.
11. VERIFY AND COORDINATE ALL ROOF, WALL AND FLOOR PENETRATIONS WITH THE
STRUCTURAL AND ARCHITECTURAL DRAWINGS PRIOR TO THE START OF
CONSTRUCTION.
12. PATCH AND PAINT ALL EXPOSED ELECTRICAL MATERIAL, INCLUDING CONDUIT, JUNCTION
BOXES, PANELS, AND DEVICES TO MATCH ADJACENT SURFACES OR AS INDICATED.
13. PROVIDE ACCESS PANELS TO ALL CONCEALED TRANSFORMERS, DEVICES, JUNCTION
BOXES AND EQUIPMENT. COORDINATE THE LOCATION OF ACCESS PANELS TO INSURE
THAT THE EQUIPMENT CAN BE MAINTAINED ADEQUATELY.
14. REPAIR ANY DAMAGE TO EXISTING CONSTRUCTION RESULTING FROM THE INSTALLATION
OF ELECTRICAL ITEMS. THE AREAS REPAIRED SHALL MATCH THE ADJACENT SURFACES
IN TEXTURE AND COLOR.
15. SEISMICALLY BRACE ALL EQUIPMENT, CONDUIT, AND CABLE TRAY IN ACCORDANCE WITH
THE CURRENT TECHNICAL MANUAL FOR SEISMIC DESIGN FOR BUILDINGS, TM 5-809-10
(ARMY), FOR SEISMIC ZONE 3.
16. NON-STRUCTURAL ATTACHMENT TO THE METAL ROOF DECK IS PROHIBITED.
CONTRACTOR SHALL PROVIDE SECONDARY SUPPORT SYSTEM (UNISTRUT, METAL
FRAMING, ETC.) TO BE ATTACHED TO THE STRUCTURAL FRAMING FOR HANGERS, RODS,
TIES, ETC. COORDINATE WITH OTHER DISCIPLINES AS REQUIRED.
LED FIXTURE WALL MOUNTED
DESCRIPTION
2'X4' LED FIXTURE, RECESSED TROFFER
SYMBOLS
MANUAL MOTOR STARTER, HP RATED
M
SWITCH, 3 WAY, 20A
SWITCH, SINGLE POLE, 20A, LETTERS SHOWN INDICATE LUMINAIRES CONTROLLED
EXIT SIGN, UNIVERSAL MOUNTED, DOUBLE FACED
EXIT SIGN, UNIVERSAL MOUNTED, SINGLE FACED
LED DOWN LIGHT, RECESSED
M
MOTOR CONNECTION
FLEXIBLE CONDUIT CONNECTION
WALL MOUNTED LIGHT FIXTURE
MOTOR STARTER, HP RATED
SAFETY SWITCH, HP RATED
ELECTRICAL LEGEND
TO CENTER
48"
POLE MOUNTED, PARKING LOT LUMINAIRE
4' CIRCULAR LED, RECESSED TROFFER
2'X4' LED FIXTURE, RECESSED TROFFER W/ EMERGENCY
BATTERY PACK
1'X4' LED FIXTURE, RECESSED TROFFER W/ EMERGENCY
BATTERY PACK
1'X4' LED FIXTURE, RECESSED TROFFER
4' LED FLUORESCENT, INDUSTRIAL
4' LED, INDUSTRIAL W/ EMERGENCY BATTERY PACK
A LIGHT FIXTURE DESIGNATOR. TYPE A INDICATED
PANELBOARD
UNDERGROUND OR BELOW SLAB RACEWAY & WIRING
JUNCTION BOX, WALL MOUNTED
JUNCTION BOX, CEILING MOUNTED
CONCEALED RACEWAY & WIRING, 3/4"C, 2#12,
#12G MIN. OR AS NOTED
HOMERUN RACEWAY & WIRING, 3/4"C, 2#12, #12G MIN.
OR AS NOTED
HATCH MARKS INDICATE NO. OF CURRENT CARRYING CONDUCTORS. GROUND WIRE
NOT SHOWN.
J
J
OCCUPANCY SENSOR SWITCH, LETTERS SHOWN INDICATE LUMINAIRES CONTROLLED
os
S
S
DEMOLITION NOTES:
1. THE DEMOLITION PLAN IS INTENDED TO SHOW THE GENERAL SCOPE OF
WORK AND DOES NOT NECESSARILY SHOW EVERY DEVICE, BOX, CONDUIT,
PANEL, ETC. TO BE REMOVED. FIELD VERIFY OTHER ELECTRICAL SERVICES
THAT MAY BE ENCOUNTERED DURING DEMOLITION AND REMOVE OR
RE-ROUTE THESE ITEMS AS REQUIRED.
2. REMOVE ALL UNUSED WIRING FROM DEMOLITION AREA NOT CONCEALED IN
CONCRETE OR PLASTER INCLUDING WIRING DISCONNECTED UNDER THIS
CONTRACT AND WIRING UNCOVERED BY DEMOLITION.
3. ALL REMAINING JUNCTION AND PULL BOXES SHALL BE ACCESSIBLE AS PER
NATIONAL ELECTRICAL CODE (N.E.C.). THE CONTRACTOR SHALL MOVE
EXISTING BOXES, ETC. AS REQUIRED BY NEW CONSTRUCTION.
4. ALL MATERIALS REMOVED REMAIN THE PROPERTY OF THE OWNER. IF THE
OWNER CHOOSES TO DISCARD THESE MATERIALS, CONTRACTOR SHALL
DISPOSE OF THE UNWANTED MATERIAL.
5. REUSE EXISTING CIRCUITS FOR THE NEW WORK. IDENTIFY AND VERIFY EACH
CIRCUIT.
48"
48"
OCCUPANCY SENSOR, CEILING MOUNTED
OS
AMPERE-INTERRUPTING CAPACITYAIC
LTG LIGHTING
AFF
ABOVE FINISH FLOOR
AMP, A
AMPERE
MIN MINIMUM
BKR
BREAKER
MLO MAIN LUGS ONLY
MTD
MOUNT OR MOUNTED
C CONDUIT, CONDUCTOR
MTG
MOUNTING
CKT CIRCUIT
NEC NATIONAL ELECTRICAL CODE
NEMA
NATIONAL ELECTRICAL
MANUFACTURE'S ASSOCIATION
NO.,#
NUMBER
D
DEEP
PB
PULLBOX
EF EXHAUST FAN PFB
PROVISION FOR FUTURE
BREAKER
EHH
ELECTRICAL HAND HOLE PNL
PANEL
EMH ELECTRICAL MANHOLE
Ø PHASE
PVC
POLYVINYL CHLORIDE
RM ROOM
EM EMERGENCY
EP EXPLOSION-PROOF
S/S STAINLESS STEEL
EQUIP
EQUIPMENT
SW SWITCH
SWBD SWITCHBOARD
TYP TYPICAL
GND GROUND
GRS
GALVANIZED RIGID STEEL
UON UNLESS OTHERWISE NOTED
H HIGH, HEIGHT
V VOLTS
HP
HORSEPOWER
W
WIRE, WIDE, WATTS, WITH
WP
WEATHERPROOF
JB JUNCTION BOX
Ø PHASE
KV KILO-VOLT
FOOT, FEET
KVA KILO-VOLT AMPERE
" INCH, INCHES
KW
KILOWATT
& AND
L LONG, LENGTH
BLDG BUILDING
ELECTRICAL ABBREVIATIONS
EXIST
EXISTING
4' LED, INDUSTRIAL W/ INTEGRAL OCCUPANCY SENSOR
4' LED, INDUSTRIAL W/ EMERGENCY BATTERY PACK AND INTEGRAL OCC. SENSOR
PB
ON-OFF PUSHBUTTON, MOMENTARY SWITCH, 120VAC
48"
S
S
REMOVE EXISTING FEEDER, BRANCH CIRCUIT, OR EQUIPMENT
ds
S
48" a,b
OCCUPANCY SENSOR SWITCH, DUAL RELAY, LETTERS SHOWN INDICATE
LUMINAIRES CONTROLLED
a a
ROOM LIGHTING CONTROLLER
PS
LIGHTING CONTROLLER SWITCH
S
48"
RACEWAY & WIRING, LOW VOLTAGE, CATEGORY 5E
LV
LV
OS
OS
MOUNTING
HEIGHT
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-001
E L E
C T
R I C
A L
L E
G E
N D
A
B B
R E
V I A
T I O
N S
A N
D
G
E N
E R
A L
N
O T
E S
RGS
RIGID GALVANIZED STEEL
RELAY
R
MAX MAXIMUM
UG UNDERGROUND
E
X
AIRPORT ROAD
TRAININGMAINTENANCEPARKING GARAGE
FIRE
PUMP
TRASH
ENCL
FUEL
TANK
WATER
TANK
PARKING LOT
MOTOR POOL
AREA
WASH RACK
LOADING
AREA
FH
FH
FH
FH
FH
EP
EP
EP
EP
EP
EP
EP
EP
ARMY RESERVES BUILDING
FOR WATER PUMP
ELECTRICAL PLAN,
SEE SHEET E-401
FOR KITCHEN
ROLL-UP DOOR
DEMO WORK,
SEE SHEET E-401
FOR SITE LIGHTING
PLAN, SEE SHEET ES102
FOR PARKING GARAGE
LIGHTING PLAN,
SEE SHEETS ED106
AND E-106
FOR ARMY RESERVE
CENTER LIGHTING PLAN,
SEE SHEETS ED101
THROUGH ED105 AND
E-101 THROUGH E-105
FOR FIRE PUMP ROOM
LIGHTING PLAN, SEE
SHEET E-107
60'
SCALE:1"= 30'
0 30'
PLAN
NORTH
SCALE: 1" = 30'-0"
OVERALL ELECTRICAL SITE PLAN
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
ES101
O V
E R
A L L
E
L E
C T
R I C
A L
S
I T
E
P
L A
N
E S
X
AIRPORT ROAD
TRAININGMAINTENANCEPARKING GARAGE
FIRE
PUMP
TRASH
ENCL
FUEL
TANK
WATER
TANK
PARKING LOT
MOTOR POOL
AREA
WASH RACK
LOADING
AREA
FH
FH
FH
FH
FH
EP
EP
EP
EP
EP
EP
EP
EP
ARMY RESERVES BUILDING
J
PARKING LOT
LIGHTING STANDARD
(TYP.), SEE
REMOVE EXISTING SIGN
LIGHT, MAINTAIN EXISTING
CIRCUITING AND CONNECT
TYPE "T" LUMINAIRE
EXISTING UG CONDUIT
AND WIRING TO
REMAIN FOR REUSE
IT ELEC ROOM
(#172)
A1
E-502
NOTE:
DISCONNECT AND REMOVE EXISTING POLE
MOUNTED LUMINAIRE, LIGHT POLE AND
CONCRETE BASE. MAINTAIN EXISTING
CIRCUITING. PROVIDE NEW CONCRETE BASE,
LIGHT POLE AND POLE MOUNTED LUMINAIRE
AND RECONNECT TO EXISTING CIRCUIT.
60'
SCALE:1"= 30'-0"
0 30'
PLAN
NORTH
SCALE: 1" = 30'-0"
SITE LIGHTING PLAN
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
ES102
S I T
E
L I G
H T
I N
G
P
L A
N
E S
X
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
A
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
NOTES:
FLAMMABLE STORAGE IS CONSIDERED CLASS I, DIV. 2
HAZARDOUS AREA.
MAINTENANCE BAY IS CONSIDERED CLASS I, DIV. 2
HAZARDOUS AREA UP TO 18" AFF.
M A
T C
H
L I N
E
S E
E
S
H E
T
DISCONNECT AND REMOVE
EXISTING HID HIGH BAY
FIXTURES, TYPICAL
DISCONNECT AND REMOVE
EXTERIOR BUILDING MOUNTED
FIXTURES, TYPICAL
MAINTAIN EXISTING LIGHTING CIRCUIT WIRING
FOR CONNECTION TO NEW LED LUMINAIRES.
DISCONNECT AND REMOVE
EMERGENCY LIGHTS
FIXTURES, TYPICAL
DISCONNECT AND
REMOVE EXIT SIGNS,
TYPICAL
DISCONNECT AND
REMOVE EXISTING
2-GANG SWITCH
AND JUNCTION
BOX, TYPICAL
DISCONNECT AND
REMOVE EXISTING
FLUORESCENT
FIXTURES, TYPICAL
DISCONNECT AND REMOVE
EXISTING FLUORESCENT STRIP
LIGHT FIXTURES, TYPICAL
DISCONNECT AND
REMOVE EXISTING
HAZARDOUS LIGHT
FIXTURES, TYPICAL
DISCONNECT AND REMOVE
EXISTING FLUORESCENT
DOWNLIGHT AND WALL-MOUNT
FIXTURES, TYPICAL
CONTRACTOR TO ENSURE CIRCUITING FOR
EQUIPMENT AND DEVICES TO REMAIN IN USE IS
MAINTAINED.
EXISTING RELAY
CAB "A" TO
REMAIN
d c f e h g
3a b c b a c
PB
a b
3a i a b
T
PB
PB
EXISTING SWITCH TO
REMAIN FOR REUSE,
TYPICAL FOR 3
MAINTENANCE BAY
OFFICE
168 169 170
SHOP
OFFICE
SHOP
OFFICE
SHOP
TOOLS & PARTS
STORAGE
ROOM WASTE
ROOM
TOILET
TOILET
IT CLOSET
MECHANICAL ROOM
OFFICE
WOMEN'S
IT ELECTRICAL
CONTR.
FLAMMABLE
BATTERY
MEN'S
MAINTENANCE
EXISTING SINGLE-GANG SWITCH TO REMAIN FOR REUSE
DISCONNECT AND
REMOVE EXISTING
SINGLE GANG
SWITCH, TYPICAL
1 2 31.61.31.1 1.91 2 31.61.31.1 1.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL LIGHTING DEMOLITION PLAN - I
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
ED101
P A
R T
I A
L
L I G
H T
I N
G
D
E M
O L I T
I O
N
P
L A
N
I
E D
X
MATCH LINE
SEE SHEET ED103
M A
T C
H
L I N
E
S E
E
S
H E
M A
T C
H
L I N
E
S E
E
S
H E
DISCONNECT AND
REMOVE EXISTING
BUILDING MOUNTED
FIXTURES, TYPICAL
DISCONNECT AND REMOVE
EXISTING FLUORESCENT
RECESSED FIXTURES, TYPICAL
DISCONNECT AND REMOVE EXISTING
2-GANG SWITCHES AND JUNCTION BOX,
TYPICAL
DISCONNECT AND
REMOVE WALL
MOUNTED OCCUPANCY
SENSOR SWITCHES
DISCONNECT AND
REMOVE EXISTING
EXIT SIGNS,
TYPICAL
DISCONNECT AND
REMOVE EXISTING
STRIP LIGHT FIXTURES,
TYPICAL
DISCONNECT AND
REMOVE EXIST SINGLE
GANG SWITCH, TYP
DISCONNECT AND REMOVE
EXISTING WRAPAROUND
FLUORESCENT FIXTURE,
TYPICAL
g h j il a b c d e f e e d a bk os os
DISCONNECT
AND REMOVE
WALL MOUNTED
OCCUPANCY
SENSOR
SWITCHES
PB PB
EXISTING
SWITCHES
TO REMAIN
FOR REUSE
NCOIC
CHAPLAIN
NCOIC
NCOIC SPECIALIST NCOIC
STORAGE
ARMORY
MUNITIONS
VAULT
UNIT STORAGE
158 159 160 161 162
STOR
SUPPLY
411TH
SUPPLY
C.co.
SUPPLY
B.co.
MANAGEMENT
LOGISTIC
MA co.
962D
INSTALL
AMMO
3 4 5 63 4 5 6
A
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
A
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8" = 1'-0"
PARTIAL LIGHTING DEMOLITION PLAN - II
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
ED102
P A
R T
I A
L
L I G
H T
I N
G
D
E M
O L I T
I O
N
P
L A
N
I I
E D
X
X X
NOTE:
1. MAINTAIN EXISTING LIGHTING CIRCUIT WIRING
FOR CONNECTION TO NEW LED LUMINAIRES.
2. CONTRACTOR TO ENSURE CIRCUITING FOR
EQUIPMENT AND DEVICES TO REMAIN IN USE IS
MAINTAINED.
SEE SHEET
ED102
DISCONNECT AND
REMOVE EXISTING
BUILDING MOUNTED
FIXTURES, TYPICAL
DISCONNECT AND
REMOVE EXISTING
STRIP LIGHT
FIXTURES, TYPICAL
DISCONNECT AND
REMOVE EXISTING
EXIT SIGNS, TYPICAL
EXISTING SWITCHES TO
REMAIN FOR REUSE
PBPB
UNIT STORAGE
3 43 4
C
D
B.9
B.9.9
C
D
B.9
B.9.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING DEMOLITION PLAN - III
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
NOTE:
1. MAINTAIN EXISTING LIGHTING CIRCUIT WIRING
FOR CONNECTION TO NEW LED LUMINAIRES.
2. CONTRACTOR TO ENSURE CIRCUITING FOR
EQUIPMENT AND DEVICES TO REMAIN IN USE IS
MAINTAINED.
ED103
P A
R T
I A
L
L I G
H T
I N
G
D
E M
O L I T
I O
N
P
L A
N
I I I
E D
X
5 6 7 8 9 10 115 6 7 8 9 10 11
DISCONNECT AND
REMOVE EXISTING
DIMMER SWITCHES,
TYPICAL FOR 4
DISCONNECT AND
REMOVE EXISTING
EXIT SIGNS, TYPICAL
DISCONNECT AND
REMOVE EXIST
2-GANG SWITCHES
AND JUNCTION BOX,
TYP
DISCONNECT AND REMOVE
EXISTING 4' CIRCULAR FIXTURE,
TYP
DISCONNECT AND
REMOVE EXISTING
INCANDESCENT
DOWNLIGHTS,
TYPICAL FOR 44
DISCONNECT AND
REMOVE EXISTING
WALL MOUNTED
FLUORESCENT
FIXTURES, TYPICAL
DISCONNECT AND
REMOVE EXISTING
SINGLE GANG
SWITCH, TYPICAL
DISCONNECT AND
REMOVE EXISTING
STRIP LIGHT
FIXTURES, TYPICAL
DISCONNECT AND REMOVE
EXISTING EXTERIOR
DOWNLIGHTS, TYPICAL
DISCONNECT AND REMOVE
EXISTING RECESSED
FLUORESCENT FIXTURES,
TYPICAL
DISCONNECT AND REMOVE
EXISTING FLUORESCENT
DOWNLIGHT FIXTURES,
TYPICAL
DISCONNECT AND REMOVE
EXISTING RECESSED
FLUORESCENT FIXTURES,
TYPICAL
DISCONNECT AND REMOVE
EXISTING 3-GANG SWITCHES,
JUNCTION BOX AND
ASSOCIATED WIRING, TYP
M A
T C
H
L I N
E
S E
E
S
H E
MATCH LINE
SEE SHEET ED105
MEN'S
TOILET
WOMEN'S
TOILET
MEN'S
LOCKER
TSG SAMOA
FINGER PRINT
FITNESS ROOM
BREAK
CORRIDOR
CORRIDOR
STORAGE
NOC
FRG
RTD
STORAGE
SUPPORT
HELP DESK
TSG SAMOA
UA / NCOIC
VTC
ROOM
ID CARD
COMMANDER
LOBBY
CORRIDOR
B. co.
100TH / 442ND INF
B. co.
CDR
411TH
FSC. 1SG
UNIT ADM.
B. co.
1SG
CDR
COMMON
AREA
CORRIDOR
109108 107106
102101
ROOM
ROOM
CORRIDOR
151A
C. co.
CDR
C. co.
100TH / 442ND INF
IMD-TECH
SUPPLY
B. co.
FSC.
411TH FSC.
ELECTRICAL
WOMEN'S
LOCKER
C. co.
1SG
411TH
FSC. XO
SIMULATOR
ROOM
XO
EXIST SW.
TO REMAIN
EXIST PANEL "L2"
EXIST TIMESWITCH "L2A"
T
EXISTING SWITCH TO
REMAIN FOR REUSE
A
B
B.0.1
B.1
B.2
B.3
B.6
B.7
A
B
B.0.1
B.1
B.2
B.3
B.6
B.7
8'0 4' 16'
SCALE:1/8"=1'-0"
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING DEMOLITION PLAN - IV
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
NOT TO SCALE
KEY PLAN
ED104
P A
R T
I A
L
L I G
H T
I N
G
D
E M
O L I T
I O
N
P
L A
N
I V
E D
X
X X
NOTE:
1. MAINTAIN EXISTING LIGHTING CIRCUIT WIRING FOR CONNECTION TO
NEW LED LUMINAIRES.
2. CONTRACTOR TO ENSURE CIRCUITING FOR EQUIPMENT AND
DEVICES TO REMAIN IN USE IS MAINTAINED.
SEE SHEET ED104
MATCH LINE
SEE SHEET ED104
DISCONNECT AND
REMOVE EXISTING
FOUR GANG
SWITCHBANK,
SINGLE GANG
SWITCHBANK, AND
ASSOCIATED
WIRING.
DISCONNECT AND
REMOVE EXISTING
BUILDING MOUNTED
FIXTURES, TYPICAL
DISCONNECT AND
REMOVE EXISTING
EXTERIOR ENTRY
DOWNLIGHT, TYPICAL
DISCONNECT AND
REMOVE EXISTING 4'
CIRCULAR FIXTURE
DISCONNECT AND
REMOVE EXISTING
FLUORESCENT
DOWNLIGHTS,
TYPICAL
DISCONNECT AND
REMOVE EXISTING
FLUORESCENT
RECESSED
LIGHTS, TYPICAL
DISCONNECT AND REMOVE
EXISTING EXIT SIGNS, TYPICAL
DISCONNECT AND
REMOVE EXISTING
STRIP LIGHT
FIXTURE, TYPICAL
DISCONNECT AND REMOVE
EXISTING TWO-GANG SWITCH,
JUNCTION BOX AND
ASSOCIATED WIRING, TYPICAL
T
ASSEMBLY
KITCHEN
STORAGE
ROOM
MECHANICAL ROOM
CORRIDOR
CONFERENCE ROOM
CLASSROOM 3
REFERENCE ROOM
COMSEC
STORAGE
HEATER
ROOM
ROOM
C. co.
TRAINING
B. co.
TRAINING OFFICE
CLASSROOM 1 DDTC
150A
CORRIDOR
411TH
EPLO / DCE
CLASSROOM 2
CORRIDOR
ELECTRICAL
OFFICE
TRAINING
OFFICE
EXIST TIME
SWITCH "L1A"
EXIST
PANEL "L1"
NOTES:
MAINTAIN EXISTING LIGHTING CIRCUIT WIRING FOR
CONNECTION TO NEW LED LUMINAIRES.
CONTRACTOR TO ENSURE CIRCUITING FOR EQUIPMENT
AND DEVICES TO REMAIN IN USE IS MAINTAINED.
EXISTING SWITCH TO REMAIN FOR REUSE
5 6 7 8 9 10 115 6 7 8 9 10 11
C
D
B.6
B.7
B.9
B.9.9
C
D
B.6
B.7
B.9
B.9.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING DEMOLITION PLAN - V
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
ED105
P A
R T
I A
L
L I G
H T
I N
G
D
E M
O L I T
I O
N
P
L A
N
V
E D
X
E.1 E.2 E.3 E.4 E.5 E.6 E.7 E.8 E.9E F
PB
PB
T
NOTE:
1. MAINTAIN EXISTING LIGHTING CIRCUIT WIRING FOR
CONNECTION TO NEW LED LUMINAIRES.
2. CONTRACTOR TO ENSURE CIRCUITING FOR EQUIPMENT
AND DEVICES TO REMAIN IN USE IS MAINTAINED.
DISCONNECT AND
REMOVE EXISTING
BUILDING MOUNTED
FIXTURES, TYPICAL
DISCONNECT AND REMOVE
EXISTING HID HIGH BAY
FIXTURES, TYPICAL
DISCONNECT AND REMOVE
EXISTING EMERGENCY
WALL MOUNTED LIGHTS,
TYPICAL
DISCONNECT AND
REMOVE EXISTING EXIT
SIGN, TYPICAL
DISCONNECT AND REMOVE
EXISTING FLUORESCENT
LIGHTS, TYPICAL
DISCONNECT AND
REMOVE EXISTING
SINGLE GANG SWITCH
EXISTING SWITCHES TO
REMAIN, TYPICAL FOR 2
EXISTING RELAY
CABINET "B" TO REMAIN
PARKING GARAGE
ROOM
PARKING GARAGE
ROOM
WASH RACK
EXISTING PANEL "PG"
TO REMAIN
EXISTING TIME SWITCH
TO REMAIN
12.9
12.8
12.6
12.4
12.2
12.1
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARKING GARAGE LIGHTING DEMOLITION PLAN
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
ED106
L I G
H T
I N
G
D
E M
O L I T
I O
N I
P
L A
N
P A
R K
I N
G
G
A R
A G
E
E D
X
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
A
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
PB
T
PB
PB
OS
OS
OS
OSPS
L V
LV
L V
OS
OS
OS
OS
PS
LVLV
L V
LV
M A
T C
H
L I N
E
S E
E
S
H E
@+18'-4" TYP.
@+22'-4" TYP.
@+26'-0" TYP.
@+22'-4" TYP.
@+18'-4" TYP.
@+13'-0"
@+13'-0"
1,3NL
TYP.
@+7'-10"
TYP.
TYP.
TYP.
TYP.
@+8'-0" l1
I
H1
H1 l1 l1 l1
B
A
B1
L
B1
L
J
S
I
Q
XX
O
Q
R
I
NOTES:
FLAMMABLE STORAGE IS CONSIDERED CLASS I, DIV. 2 HAZARDOUS
AREA. ALL CONDUIT IN THIS ROOM SHALL BE EXPOSED RGS WITH
SEALS AS REQUIRED BY NEC. ALL DEVICES AND FIXTURES WITHIN
THE ROOM SHALL BE U.L. LISTED FOR CLASS I, DIV. 2.
MAINTENANCE BAY IS CONSIDERED CLASS I, DIV. 2 HAZARDOUS
AREA UP TO 18" AFF. MAINTAIN ALL CIRCUITS, DEVICES AND
FIXTURE INSTALLATION ABOVE 18" IN THIS ROOM.
1,3NL1,3NL
1,3NL
10,12 18,20 14,16 18,20 10,12
10,12 18,20 14,16 18,20
18,20
18,20
10,12
10,12
10,12
1,3NL
14,16
14,16
18,20
18,20
10,12
10,12
10,12
1,3NL
18,20 14,16
18,20 10,12
X
@+13'-0"
13NL
21c
21c
21b 21b
13NL
21a
21a
21a
21a
21a
21a
13NL
13NL
17,17c 17c 17c
17c17c17c
17a
15c
13NL
15,15a
15a
15,15a
15b 15a 15b 15a
15a15b 15b
15i
19b 19b 19b
19b
19b
19,19a
19,19a
19,19a
21e
21e
21e
L
21d
21d
21d 19b
F1
EXIST RELAY
CAB "C"
EXIST TIME
SWITCH "L3A"
X
F1
L
L
13NL
EM
@+8'-0"
U
13NL
EM
Q
U
@+8'-0"
L1
Q
@+13'-0"
EM
U
@+8'-0"
"EM" INDICATES FIXTURE
WITH EMERG. BATTERY PACK.
PROVIDE UN-SWITCHED
PHASE-LEG AS REQUIRED, TYP.
U
EM
EM
13NL
U
@+8'-0"
R
@+8'-0"
13NL
Q
@+13'-0"
EM
U
@+8'-0"
@+8'-0"
X
EXISTING
RELAY CAB "A"
PROVIDE NEW LED HIGH BAY
FIXTURES, MATCH EXISTING
MOUNTING HEIGHTS. CONTRACTOR
TO ENSURE THAT FIXTURES CLEAR
EXISTING CRANE. INTERCEPT
EXISTING WIRING AND EXTEND TO
NEW FIXTURE.
MOUNTING HEIGHTS SHOWN ARE APPROXIMATE. MOUNT NEW
LUMINAIRES TO MATCH EXISTING MOUNTING HEIGHTS.
4.
EXIST PANEL "L3"
RETAIN EXISTING INTERLOCK BETWEEN NEW LIGHTS AND EXISTING
EXHAUST FAN, SEE DETAIL D4/E-601.
a a
LV
e os i os a b
LV
LV
a,b b a
LV
LV
c,d ds e,f ds g,h ds a,b a b os c
@+13'-0"
Q d os a
15e 15g
15d 15f 15h
19b 19b 19b 19b
17b
MAINTENANCE BAY
OFFICE
168 169 170
SHOP
OFFICE
SHOP
OFFICE
SHOP
TOOLS & PARTS
STORAGE
ROOM WASTE
ROOM
TOILET
TOILET
IT CLOSET
MECHANICAL ROOM
OFFICE
WOMEN'S
IT ELECTRICAL
CONTR.
FLAMMABLE
BATTERY
MEN'S
MAINTENANCE
A A
17b
H
TYP.
1 2 31.61.31.1 1.91 2 31.61.31.1 1.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING PLAN - I
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-101
P A
R T
I A
L
L I G
H T
I N
G
P
L A
N
I
E
X
OSPS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
L V
TYP.
TYP.
AAAA
l1 l1 l1 l1 l1 l1 l1 l1
I
28B
28B
28B
28B
28B
26A
28B
28B
28B
28B
30B
30B
30B
30B
30B
26A
30B
30B
30B
26A
26,26A
26,26A
26A
26A
26A
26A
26,26A
28B
28B
28,28B
28B
28B
24e
24e
24e
24,24e
24,24e
24d
24a
24c
24,24b
X
23k 23l 23i 23j 23g 23h 23f 23e
A
23b 23a
13NL
13NL
26,26A 26A
26 26A
26,26A
32B
32B
32B
32B
32B
32B
32B
32B
32B
32B
32B
32B
32B
32B 32B
32B
32B
26A
32B
26A
26A
26A
26A
26,26A
26,26A
32,32B
X
26,26A
24e
24e
24e
24e
24e
24e
R
@+8'-0"
R
@+8'-0"13NL
@+8'-0"
R
UNSWITCHED
FIXTURE
UNSWITCHED
FIXTURE
MATCH LINE
SEE SHEET E-103
M A
T C
H
L I N
E
S E
E
S
H E
M A
T C
H
L I N
E
S E
E
S
H E os a os b ds e,f ds g,h ds i,j ds k,l os c os b os a e e
LV
G1
G1 os d
G1
B
G
G1
X1
I1
I1
A
NCOIC
CHAPLAIN
NCOIC
NCOIC SPECIALIST NCOIC
STORAGE
ARMORY
MUNITIONS
VAULT
UNIT STORAGE
158 159 160 161 162
AMMO STOR
SUPPLY
411TH
SUPPLY
C.co.
SUPPLY
B.co.
MANAGEMENT
LOGISTIC
MA co.
962D
INSTALL
24c
PB
PB
CONNECT NEW
SWITCHES TO
EXIST CIRCUITS
CONNECT NEW
SWITCHES TO
EXIST CIRCUITS
l1a b a b
C
PB PB
3 4 5 63 4 5 6
A
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
A
B
C
B.0.1
B.1
B.2
B.3
B.6
B.7
B.9
B.9.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING PLAN - II
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-102
P A
R T
I A
L
L I G
H T
I N
G
P
L A
N
I I
E
X X
X
NOTE:
1. MOUNTING HEIGHTS SHOWN ARE APPROXIMATE.
MOUNT NEW LUMINAIRES TO MATCH EXISTING
MOUNTING HEIGHTS.
l1 l1 l1 l1
13NL
13NL 13NL
28B
26,26A
26A
28B
28B
28B
28B
28B
26,26A
30B
30B
30B
30B
30B
30B
30B
X
26A
26A
26A
13NL
13NL
30,30B
26A
26A
28,28B
28B
X
R
@+8'-0"
R
@+8'-0"
R
@+8'-0"
13NL
@+8'-0"
U
EM
"EM" INDICATES FIXTURE WITH
EMERG. BATTERY PACK.
PROVIDE UN-SWITCHED
PHASE-LEG AS REQUIRED, TYP.
R
@+8'-0"
R
@+8'-0"
X
MATCH LINE
SEE SHEET E-102
OS
OS
OS
OS
UNIT STORAGE
13NL
R
@+8'-0"
PBPB
l
TYP
3 43 4
C
D
B.9
B.9.9
C
D
B.9
B.9.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING PLAN - III
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-103
P A
R T
I A
L
L I G
H T
I N
G
P
L A
N
I I I
E
X
5 6 7 8 9 10 115 6 7 8 9 10 11
TYP.
C1
C1
L2
E
B
B1
B1
L1
B1
L
D1
D1
A
TYP.
D
TYP.
D1
A
B
B
D1
B
TYP.
B1
A
TYP.
E
B1
B
TYP.
B1
A
TYP.
A
TYP.
B
TYP.
A
TYP.
A
I
A
TYP.
B
TYP.
M
TYP.
L
L
K1
K1
K
C
A
B
TYP.
L
TYP.
K
TYP.
B
TYP.
L1
B1
L
E
B
B1
E
L
L2
TYP.
F
TYP.
L2
L
TYP.
L
TYP.
L
L2
F
TYP.
B1
L
TYP.
C1
B
B
A B
B
B
L2-12
A
TYP.
b a d c d c c a a c a,b a b
LV
LV
a b c c,d c a,b b a i,j g,h a,b c,d a,b ds c,d e,f g,h c,d e f,g h,i j,k
LV
LV
ds e,f f e
13a
13b
13a
13a1313a
13b
13a
13b
12NL
12NL
12NL
12NL
12NL
12NL
11c
11b 9a
11c
11c
11c
11b
11b
11,11b
11c
11c
11c
11c
11b
11b
11b
11b
9a
9a
9a
9a
9a
9a
9,9a
B1
12NL
LV
LV
a b
LV LV
13b
B1
13b
L
7d
7d
7c d
7b 7a c
10a
10a
10a
10a
10a10
10a
10a
10a
10a c
20NL
LV
b a
LV
2j 2j 2h
2i 2i 2g
11a
2a
2b
1a
1b
1g
1g g
3c
3c
3d 3d
3a 3a 3a
3a
3b 3b 3b 3b 3b
19c
19d19d
19d
19d
19d
19d
19d 19d
19,19c
19c
19c
19c
19c
19,19c
3a e
19c
19a
17d
19b
19,19c
17d
17c
17c
17c
17c
17c
17,17c
17c
17c
17c
17,17d
4a
6b
8c
10d a b c d
2a
2b
20NL
11 11a
20NL
20NL
L1
2e
2f
2d 2c
2e
11a
11b
11b ab
L
12a
12b
12d
12c
12f
12e
12h 12g
20NL
20NL
a b c
14a
16b 14c
14a 16b
14a
14a 16b
14a 16b
16,16b
16,16b
16b
14c
14c
14c
14c
16b
16b
16b
20NL
18k18j 18i18h
18g 18f18e
20NL
LV
b a
11b
11a
11a c a,b b
11b
18c
18d
18b
18a
18b
1d
1c 1c 1c
1f
1e
1f
1e
1f
1e f
7f
7f
17d
17d
19e
19,19e 19,19e
19e 19e
19e
19e19e 19e
10a
10a
LV
X1
EXIST PANEL "L2"
X
LV
X
X
X
X
X
13a
X
X
10c a
10a
E
U
EM
R
@+8'-0"
EM
U
@+8'-0"
EM
U
"EM" INDICATES FIXTURE WITH EMERGENCY
BATTERY PACK. PROVIDE UN-SWITCHED
PHASE-LEG AS REQUIRED, TYP.
20NL
R
@+8'-0"
EM
U
@+8'-0"
R
@+8'-0"
R
@+8'-0"
EM
U
@+8'-0"
13b
EXIST TIMESWITCH "L2A"
L2-20NL
VIA
TIMESWITCH
"L2A"
M A
T C
H
L I N
E
S E
E
S
H E
MATCH LINE
SEE SHEET E-105
LV
LV
LV
LV
LV
a,b b,c a,b a a b,c
LV
a,b
LV
b
LV
LV
c,d a,b e e d a,b
LV
LV
os
LV
a,b
LV
LV
ds c ds ds ds a os b a
LVLV
a,b ds
LV
ds ds ds os
4a
6b
8c
10d
4a
6b
8c
10d
4a
6b
8c
10d
4a
6b
8c
10d
4a
6b
8c
10d a b c d a b c d
4a
6b
8c
10d
4a
6b
8c
10d
4a
6b
8c
10d a b c d
4a
6b
8c
10d
4a
6b
8c
10d
LV
LV
LV
LV
a
19a 19a 19a 19a
17d 17d
L
TYP.
17d 17d 19b 19b 19b 19b os
LV
a,b
R
@+8'-0"
@+8'-0"
@+8'-0"
12NL 12NL
a,b e,f a,b c a,b ds
LV
a c,d 19 c c ds ds ds
10c ds os c
3a,b
LVLV
LV
LV
a d
LV
LV
PROVIDE DIMMING
ROOM CONTROLLER
TYP FOR 4
T
OS
OS
OS OS
OS
OSOS
OS
OS
OS
OSOS
OS
OS
OS
OS
OS
OS
OS
PS
PS
PS
PS
PS
PS
PS
OS
OS
OSOS
OS
OS
PS
PS
OS
OS
OS
OS
PS
OS
OS
OS
PS
OS
LV
PS
PS
OS
OS
OS
OS
OS
OS
OS
OS
PS
PS
PS
LV
LV
LV
OS
OS
OS
OS
LV
LV
LV
LV
PS
PS
PS
PS
OSOS
L V
LV
LVLV
L V
LV
LV
L V
L V
LV LV
LV
L V
L V
LV
LV
LV
LV
LV
L V
L V
L V
L V
L V
LV
LV
LV
LV
LV
LV
LV
LV
LV LV
L V
LV
LV
LV LV
LV
LV
LV
LV
LV
LV
LVLV
L V
LV
LV
LV
LV
L V
L V
L V
LV
L V
L V
L V
L V
LV
L V
L V
LV
L V
L V
L V
L
V
LV
LV
LV
L V
LV
LV
L V
MEN'S
TOILET
WOMEN'S
TOILET
MEN'S
LOCKER
TSG SAMOA
FINGER PRINT
FITNESS ROOM
BREAK
CORRIDOR
CORRIDOR
STORAGE
NOC
FRG
RTD
STORAGE
SUPPORT
HELP DESK
TSG SAMOA
UA / NCOIC
XO
VTC
ROOM
ID CARD
COMMANDER
LOBBY
CORRIDOR
B. co.
100TH / 442ND INF
B. co.
CDR
411TH
FSC. 1SG
UNIT ADM.
B. co.
1SG
CDR
COMMON
AREA
CORRIDOR
109108107106104
103102
130131
ROOM
ROOM
CORRIDOR
151A
C. co.
CDR
C. co.
100TH / 442ND INF
IMD-TECH
SUPPLY
B. co.
FSC.
411TH FSC.
ELECTRICAL
WOMEN'S
LOCKER
C. co.
1SG
10a
16b 16b
16b 16b 16b
14a 14c
16b 16b 16b
411TH
FSC. XO
11a11
2f
SIMULATOR
ROOM
a,b
1d 1d
19c
17c d
C
TYP.
A
B
B.0.1
B.1
B.2
B.3
B.6
B.7
A
B
B.0.1
B.1
B.2
B.3
B.6
B.7
8'0 4' 16'
SCALE:1/8"=1'-0"
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING PLAN - IV
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
NOT TO SCALE
KEY PLAN
E-104
P A
R T
I A
L
L I G
H T
I N
G
P
L A
N
I V
E
X X
X
NOTES:
MOUNTING HEIGHTS SHOWN ARE APPROXIMATE. MOUNT NEW
LUMINAIRES TO MATCH EXISTING MOUNTING HEIGHTS.
INTERLOCK EXISTING EXHAUST FANS TO NEW LED LIGHTS,
SEE DETAIL D4/E-501.
3.
PROVIDE CONTROL WIRING FROM DIMMING ROOM
CONTROLLERS TO DIMMABLE LED DRIVERS,
SEE DETAIL B1/E-501.
A1
A3
A1
A
A1
TYP.
A
I1
B
A2
TYP.
K2
TYP.
A3
A3
TYP.
E
K
TYP.
K1
I1
I
TYP.
B1
I1
D
TYP.
D1
A
TYP.
A
TYP.
B
L1
B1
A
TYP.
A1
A
TYP.
A1
B1
B1
A
TYP.
A
TYP.
A
TYP.
B
TYP.
R
@+8'-0"
I
A
I1
LV
a a b c d
LV
LV
c d
LV
LV
a,b ds a b c d a b c d a b a b a b c d
23a
23,23b 23a
23g 23g 23g
23c
23,23c
23,23d
23d
23e
2b 4,4d
13c
13c 13c 13
13a
13c
13a
13b
15b
15a c
13c
13c
13c
13c
13c
13a
15a
15d
15c
20NL
20NL
20NL
20NL
20NL
20NL
17,17a
17b
17a
17,17c
17b 17a
17c
17a
11a
11a
11a ba
11b
21c
11,11a
21d
20NL
20NL
21a
21b
21a
21b
21a
21c c
7e e
7b
7a
7e
7e
7c
7d cc c b a h g
23,23f f L1-12
12NL
e
23d
23c
23c
23c
23,23c
A1
3a
3a
3a
3a 3a
4,4d
4d
2,2b
2b
2b
2b
12NL
12NL
R
@+8'-0"
X
X
X
X
X
R
@+8'-0"
R
@+8'-0"
EM
@+8'-0"
U
20NL
R
@+8'-0"
R
@+8'-0"
R
@+8'-0"
EM
U
@+8'-0"
"EM" INDICATES FIXTURE WITH
EMERGENCY BATTERY PACK.
PROVIDE UN-SWITCHED
PHASE-LEG AS REQUIRED, TYP.
12NL
U
EM
@+8'-0"
R
@+8'-0"
12NL
U
EM
@+8'-0"
R
@+8'-0"
EXIST TIMESWITCH
"L1A"
13NL
13NL
@+8'-0"
U
EM
13NL
R
@+8'-0"
@+8'-0"
U
EM
MATCH LINE
SEE SHEET E-104
MATCH LINE
SEE SHEET E-104
LV
LV
LV
a,b c,d
LVLV
a,ba,b
LV
LV
c,d a,b
LV
LV
a,b a,b
LV
c,d
LV
LV
LV
LV
a
LV
a,b
LV LV
c a,b a,b a,b
LV
LV
b d d b
SWBK "A"
SEE DET. A1/E-501
os c
LV
LV
os d
EXIST
PANEL "L1"
a,b
TYP.
os c
T
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
OS
PS
PS
PS
PS
PS
OS
OSOS
OS
PS
OS
OS
OS
PS
L V
L V
L V
PS
PS
PS
PS
PS
PS
OS
PS
PS
L V
LV
L V
LV
L V
L V
L V
L V
L V
L V
LV
LV
LV LV
L V
LV
L V
L V
L V
L V
LV
LV
LV
LV
LV
L V
LV
LV
LV
LV
L V
L V
L
V
LV
LV
LV
L V
LV
LV LV
23h
2b
ASSEMBLY
KITCHEN
STORAGE
JANITOR
ROOM
MECHANICAL ROOM
CORRIDOR
CONFERENCE ROOM
CLASSROOM 3
REFERENCE ROOM
COMSEC
STORAGE
HEATER
ROOM
C. co.
TRAINING
B. co.
TRAINING OFFICE
CLASSROOM 1 DDTC
150A
CORRIDOR
411TH
EPLO / DCE
CLASSROOM 2
CORRIDOR
ELECTRICAL
3a 3a 3a
2b
2,2b
3a
2b 2b
2b
2b 4d
4d
4d 4d
4d 4d
4d
3a 3a
4d4d
3a
3a
3a
3a
7c
7d 7d 7d
7,7d
7,7c7,7c 7c 7c 7c
21d21d21d
21c 21c 21c
11b 11b 11b
11b 11b 11b 11b
11a 11a 11a 11a
11a 11a 11a
17d 17c
17d 17c
15d 15d
15c 15c
15a
15a 15a 15a
15b 15b 15b
13b 13b 13b
13a 13a
OFFICE
TRAINING
OFFICE
B
23e
A3
L V a
OS
LV
a
OS
a
OS
LV
OS
a
PROVIDE DIMMING
ROOM CONTROLLER,
TYP FOR 3
LV
LV
5 6 7 8 9 10 115 6 7 8 9 10 11
C
D
B.6
B.7
B.9
B.9.9
C
D
B.6
B.7
B.9
B.9.9
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARTIAL LIGHTING PLAN - V
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-105
P A
R T
I A
L
L I G
H T
I N
G
P
L A
N
V
E
X X
X
NOTES:
1.
MOUNTING HEIGHTS SHOWN ARE APPROXIMATE.
MOUNT NEW LUMINAIRES TO MATCH EXISTING
MOUNTING HEIGHTS.
PROVIDE CONTROL WIRING FROM DIMMING ROOM
CONTROLLERS TO DIMMABLE LED DRIVERS,
SEE DETAIL B1/E-501.
2.
E.1 E.2 E.3 E.4 E.5 E.6 E.7 E.8 E.9E F os
1,3
@+7'-10"
@+8'-0"
1,3
@+18'-8"
@+13'-0"
TYP.
Q
O
TYP.
R
XX
5NL
1,3
1,3
2,4
6,8
2,4
6,8 2,4
6,8
2,4
6,8
2,4 6,8
2,4
6,8
2,4
6,8 2,4
6,8
5NL
1,3NL
@+13'-0"
Q
TYP.
1,3
1,3
NL
NL1,3 1,3 NL
NL
NL
NL
NL NL1,3
NL
1,3
NL1,3
NL
R
5a
J
TYP.
5NL
1,3
NL
@+13'-0"
R
@+8'-0"
5a
NL
1,3
X
X
EMERGENCY
BATT. PACK,
(TYP.)
PARKING GARAGE
ROOM
WASH RACK
PB
PB
T
EXIST PANEL "PG"
EXIST TIMESWITCH
EXIST RELAY
CABINET "B"
12.9
12.8
12.6
12.4
12.2
12.1
8'0 4' 16'
SCALE:1/8"=1'-0"
NOT TO SCALE
KEY PLAN
PLAN
NORTH
SCALE: 1/8"=1'-0"
PARKING GARAGE LIGHTING PLAN
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-106
P A
R K
I N
G
G
A R
A G
E
L I G
H T
I N
G
P
L A
N
E
X X
X
NOTE:
1. MOUNTING HEIGHTS SHOWN ARE APPROXIMATE.
@+8'-0"
20b
20a
20a
20b
WATER TANK
EXISTING
POWER JB
20b a b
DISCONNECT AND REMOVE
EXISTING FLUORESCENT
STRIP FIXTURE, MAINTAIN
CIRCUITING FOR
CONNECTION TO LUMINAIRE
TYPE "J", TYPICAL FOR 2
DISCONNECT AND
REMOVE EXISTING HID
WALL-PACK FIXTURE,
MAINTAIN CIRCUITING FOR
CONNECTION TO
LUMINAIRE TYPE "R",
TYPICAL FOR 3
FIRE PUMP
PLAN
NORTH
8'0 4' 16'
SCALE:1/8"=1'-0"
SCALE: 1/8" = 1'-0"
LIGHTING PLAN - FIRE PUMP BUILDING
C1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-107
L I G
H T
I N
G
P
L A
N
F
I R
E
P
U M
P
B
U I L D
I N
G
E
X X
X
NOTE:
1. MOUNTING HEIGHTS SHOWN ARE APPROXIMATE.
M
ROLL-UP DOOR
DISCONNECT AND REMOVE ROLL-UP
DOOR CONNECTION, MANUAL MOTOR
STARTER AND ASSOCIATED WIRING
AND CONDUIT. EXISTING ROLL-UP
DOOR CIRCUIT BREAKER IN PANEL "P1"
TO REMAIN AS SPARE. REVISE PANEL
DIRECTORY TO READ AS "SPARE".
EXIST
PANEL "E"
EXIST
PANEL "K1"
EXIST "MDP"
EXIST PANEL L1
EXIST PANEL P1
EXIST FA
CABINET
EXIST PANEL "L3"
EXIST PANEL "P3"
EXIST PANEL "M5"
EXIST PANEL "M4"
BP-1
BP-2
M
M
P3-38,40,42
M5-37,39,41
EXIST AHU-9
EXIST AHU-14
EXIST
COMPRESSOR
VFD
VFD
PLAN
NORTH
8'0 4' 16'
SCALE:1/8"=1'-0"
SCALE: 1/8" = 1'-0"
MECHANICAL ROOM - WATER PUMP ELECTRICAL PLAN
B2
SCALE: 1/8" = 1'-0"
KITCHEN - ROLL UP DOOR DEMOLITION PLAN
B1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-401
E
X X
X
E N
L A
R G
K
T
C H
C
H A
N I C
A L
R O
L E
C T
R I C
A L
P
L
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-501
L I G
H T
I N
G
C
O N
T R
O L
D
I A
G R
A M
S
E
X X
X
1P20A
EXIST PARTIAL
208/120V, 3Ø, 4W
PANEL
CKT. A
ON- OFF LIGHTING
CONTROLLER
CKT. Aa
TO LUMINAIRES
1P20A
EXIST PARTIAL
208/120V, 3Ø, 4W
PANEL
CKT. B
CKT. Ba
TO EXIST EXHAUST FAN
OCCUPANCY
SENSOR
OCCUPANCY
SENSOR
1P20A
PARTIAL 208/120V,
3Ø, 4W PANEL
LOW VOLTAGE
SWITCH
ON-OFF ROOM
CONTROLLER
TO LUMINAIRES
PROVIDE LOW VOLTAGE WIRING PER
MANUFACTURER'S RECOMMENDATIONS
2#12,#12G
2#12,#12G
3#12,#12G
INTERCEPT EXISTING
LIGHTING HOMERUN IN
JUNCTION BOX.
EXTEND CIRCUIT TO
ROOM CONTROLLER.
OCCUPANCY
SENSOR
1P20A
PARTIAL 208/120V,
3Ø, 4W PANEL
LOW VOLTAGE
DIMMING SWITCH
DIMMING ROOM
CONTROLLER
PROVIDE LOW VOLTAGE WIRING
PER MANUFACTURER'S
RECOMMENDATIONS
0-10V DIMMABLE LED DRIVER
PROVIDE CONTROL WIRING PER
MANUFACTURER'S
RECOMMENDATIONS
WALL-MOUNTED
OCCUPANCY SENSOR,
DUAL RELAY
NEUTRAL
BROWN
RED
WHITE
NEUTRAL
LINE BLACK
BLUE
WHITE
GREENGROUND
LUMINAIRES,
TYPICAL
WALL-MOUNTED
OCCUPANCY SENSOR,
SINGLE SWITCH
NEUTRAL
RED
WHITE
NEUTRAL
LINE BLACK
WHITE
GREENGROUND
LUMINAIRE
LOW VOLTAGE
DIMMING SWITCHES,
TYP
"D""B""A"
2#12,#12G
2#12,#12G
NOTE: PROVIDE NUMBER OF ROOM CONTROLLERS,
OCCUPANCY SENSORS, AND LOW VOLTAGE SWITCHES
AS REQUIRED.
NOTE: PROVIDE NUMBER OF OCCUPANCY SENSORS AND
LOW VOLTAGE SWITCHES AS REQUIRED.
INTERCEPT EXISTING
LIGHTING HOMERUN IN
JUNCTION BOX. EXTEND
CIRCUIT TO ROOM
CONTROLLER.
R
J
OS
OS
J
OS
NOT TO SCALE
TYPICAL CEILING-MOUNT OCCUPANCY SENSOR CONTROL DIAGRAM
C1
NOT TO SCALE
TYPICAL OCCUPANCY SENSOR DIMMING CONTROL DIAGRAM
B1
NOT TO SCALE
ASSEMBLY SWITCHBANK "A" DETAIL
A1
NOT TO SCALE
TYPICAL FAN/LIGHT INTERLOCK CONTROL DIAGRAM
C3
NOT TO SCALE
TYPICAL OCCUPANCY SENSOR BI-LEVEL CONTROL DIAGRAM
B3
NOT TO SCALE
TYPICAL OCCUPANCY SENSOR CONTROL DIAGRAM
A3
RECONNECT BRANCH CIRCUIT
WIRING TO EXISTING RELAY
PROVIDE FLUSH MOUNTED BOX, GANGS AS
REQUIRED. REUSE EXISTING CONDUIT TO
CEILING SPACE FOR LOW VOLTAGE WIRING.
PATCH AND PAINT TO MATCH
ADJACENT SURFACES.
LUMINAIRE TYPE "Y"
FINISHED
GRADE
NOTE:
GALV. STEEL FIXTURE ARM,
DARK BRONZE ANODIZED
FINISH.
AREA LIGHT ASSEMBLY, INCLUDING LUMINAIRE,
POLE AND FOUNDATION SHALL WITHSTAND
WINDS UP TO 150 MPH GUSTING WITHOUT
PERMANENT DEFORMATION, IN ACCORDANCE
WITH AASHTO LTS.
GALV. STEEL POLE,
DARK BRONZE ANODIZED
FINISH W/ VIBRATION DAMPER.
HANDHOLE, GASKETED
WITH STAINLESS STEEL
RETAINING SCREWS
GROUND LUG AND
#8 B.C. GROUND
BASE COVER
EXISTING COPPER CLAD
GROUND ROD WITH
CLAMP.
STAINLESS STEEL
LEVELING NUTS
AND WASHERS
CONCRETE FOUNDATION
3000 PSI IN 28 DAYS
1'-0"
NOT TO SCALE
POLE LIGHT DETAILS
A1
T
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-502
E L E
C T
R I C
A L
D
E T
A I L S
E
X X
X
PENDANT MOUNTED
LUMINAIRE
ALL SEISMIC CABLES
ARE 3/32"
SEISMIC CABLE
VERTICAL CABLES ARE
PRIMARY SUSPENSION
EYE BOLT
SIDE CABLE EXIT
GATED HOOK
EYE BOLT
SIDE CABLE EXIT GATED HOOK
ALL SEISMIC
CABLES ARE 3/32"
VERTICAL CABLES ARE PRIMARY
SUSPENSION
CABLE CLAMP
45°
45°
NOT TO SCALE
SEISMIC BRACING FOR TYPICAL SINGLE PENDANT LUMINAIRE
C3
NOT TO SCALE
SEISMIC BRACING TO CEILING FOR TYPICAL 4' LINEAR FIXTURE
A3
20"
APPROX 24"
C
I
R
C
L
E
B
O
L
T
BASE COVER
4-#7 VERTICAL WITH
#3 TIES SPACED AS
SHOWN IN ELEVATION
20"
1" PVC
1" PVC
REBARS @ 5" O.C.
REBARS @ 5" O.C.
BALANCE OF
REBARS @ 10" O.C.
GROUT UNDER POLE BASE
STAINLESS STEEL
ANCHOR BOLTS
3/4" DIA. x 2'-4" L
1" ROUNDED EDGE
ALL AROUND
6" SQUARE, 1/4" THICK
H
T
M
Y
R
E S
E R
C
I L I T
I E
S
T A
F U
N A
A
M E
R I C
M
O A
D
G N
E-503
E L E
C T
R I C
A L
D
E T
A I L S
E
X X
X
LUMINAIRE PENDANT
CANOPY WITH BALL
ALIGNER
PIPE HANGER WITH
CLOSURE BOLT
LUMINAIRE
ROOF STRUCTURE
C-CHANNEL BETWEEN ROOF
PURLINS WHERE REQUIRED
SWING CONNECTOR
0.4" DIA. THREADED ROD
SWING CONNECTOR
PENDANT CONDUIT STEM
JUNCTION BOX
SEE NOTE 2
NOTE:
1. PROVIDE 3 POINT BRACING FOR ALL LUMINARIES
WITH PENDANT STEMS IN EXCESS OF 4 FEET.
2. HORIZONTAL RESTRAINT: THE ANGLE OF THE ROD
SHALL NOT EXCEED 45 DEGREES FROM THE PLANE
OF THE CEILING.
LUMINAIRE
JUNCTION BOX
C-CHANNEL
PENDANT
CONDUIT STEM
LUMINAIRE
JUNCTION BOX
PENDANT BRACE
AT 3 POINTS
LUMINAIRE
PENDANT
CONDUIT STEM
C-CHANNEL
C-CHANNEL
PENDANT
CONDUIT STEM
END VIEW SIDE VIEW
PLAN VIEWSIDE VIEW
NOT TO SCALE
TYPICAL PENDANT LUMINAIRE BRACING DETAILS
A2
18" MAX.
C-CHANNEL
EYE BOLT
SIDE CABLE EXIT GATED HOOK
ALL SEISMIC CABLES
ARE 3/32"
VERTICAL CABLES ARE PRIMARY SUSPENSION
CABLE CLAMP
45°
45°
NOT TO SCALE
SEISMIC BRACING TO CEILING FOR TYPICAL 4' LINEAR FIXTURE ROWS
C2
SIMILAR AS TYPE A, EXCEPT WITH
EMERGENCY BATTERY PACK &
CHARGER.
2'x4' HIGH EFFICIENCY TROFFER. 3.5"
DEEP, STATIC FIXTURE, STEEL
HOUSING, REFLECTIVE MATTE WHITE
FINISH. TOOL-LESS, ROOM SIDE
ACCESS TO ALL COMPONENTS.
FROSTED RIBBED ACRYLIC DIFFUSER.
LED LIGHT ENGINE, CONSTANT
CURRENT, CLASS 2 DRIVER, 120V
RECESSED
GRID
LED,
64W
6000 LM
3500K
MIN
80CRI
TYPE LAMP MOUNTING DESCRIPTION
DESCRIPTION
MOUNTINGLAMPTYPE
LED
81.3W
3200 LM
3500K
MIN 80CRI
WALL
SURFACE
4' ARCHITECTURAL WALL MOUNT
FIXTURE. STEEL HOUSING, SOLID TOP,
WHITE FINISH. FROSTED ACRYLIC
0.125" TH. LENS. 100% DOWNLIGHT.
LED LIGHT ENGINE, CONSTANT
CURRENT, CLASS 2 DRIVER, 120V
SIMILAR AS TYPE C, EXCEPT WITH
EMERGENCY BATTERY PACK &
CHARGER.
1'x4' HIGH EFFICIENCY TROFFER. 4"
DEEP, STATIC FIXTURE, STEEL
HOUSING, REFLECTIVE MATTE WHITE
FINISH. TOOL-LESS ACCESS TO ALL
COMPONENTS. ONE-PIECE FROSTED
RIBBED ACRYLIC DIFFUSER. LED
LIGHT ENGINE, CONSTANT CURRENT,
CLASS 2 DRIVER, 120V
RECESSED
GYPBOARD
TYPE LAMP MOUNTING DESCRIPTION
DESCRIPTIONMOUNTINGLAMPTYPE
LED
44W
3800 LM
3500K
MIN 80CRI
1'x4' HIGH EFFICIENCY FIXTURE. STEEL
HOUSING, BAKED WHITE ENAMEL
FINISH. FROSTED, RIBBED ACRYLIC
DIFFUSER. TOOL-LESS ACCESS TO ALL
COMPONENTS. LED LIGHT ENGINE,
CONSTANT CURRENT, CLASS 2
DRIVER, 120V
SIMILAR AS TYPE G, EXCEPT WITH
EMERGENCY BATTERY PACK &
CHARGER.
CEILING,
SURFACE
OR STEM
MTD AS
INDICATED
8" DIAMETER LED DOWNLIGHT.
ONE-PIECE STEEL PLATFORM WITH
PRE-WIRED JUNCTION BOX. ALUMINUM
SEMI-DIFFUSE UPPER REFLECTOR.
WHITE PAINTED SELF-TRIM. LED
DRIVER, UL CLASS 2, 0-10V DIMMING
CAPABILITY.
120V.
LED
39W
3000 LM
3500K
MIN 80CRI
TYPE LAMP MOUNTING DESCRIPTION
RECESSED
DESCRIPTIONMOUNTINGLAMPTYPE
RECESSED
GRID
SIMILAR AS TYPE B, EXCEPT WITH
EMERGENCY BATTERY PACK &
CHARGER.
A
A1
B
B1
C
C1
F
DESCRIPTIONMOUNTINGLAMPTYPE
E
LED
89W
5500 LM
3500K
80CRI
RECESSED
GYPBOARD
4' DIAMETER CIRCULAR REGRESSED
STATIC LED TROFFER. STEEL HOUSING,
BAKED WHITE ENAMEL FINISH. FLUSH
WHITE ACRYLIC DIFFUSER. LOW OUTPUT
LED, CONSTANT CURRENT DRIVER WITH
<20% THD,120V
G
G1
STEM
MOUNTED
DESCRIPTIONMOUNTINGLAMPTYPE
LED
32W
5200 LM
3500K
MIN 80CRI
4' LED INDUSTRIAL FIXTURE WITH
SYMMETRIC REFLECTOR. HEAVY
GAUGE STEEL, HIGH-GLOSS BAKED
WHITE ENAMEL FINISH. SILVER LIGHT
BAR FINISH. CLASS 1, HIGH
EFFICIENCY LED DRIVER, THD<20%,
120V
H
H1 SIMILAR AS TYPE H, EXCEPT WITH
EMERGENCY BATTERY PACK &
CHARGER.
SIMILAR AS TYPE G, EXCEPT WITH
EMERGENCY BATTERY PACK &
CHARGER.
I1
I
4' LED LOW-PROFILE WRAP STRIP
LIGHT. HEAVY GAUGE STEEL HOUSING
WITH ALUMINUM END PLATES, BAKED
WHITE ENAMEL FINISH. WHITE ACRYLIC
SHIELDING, LED LIGHT ENGINE,
CONSTANT CURRENT, CLASS 2 DRIVER,
INTEGRAL OCCUPANCY SENSOR (AS
INDICATED), 120V
LED
40W
2900 LM
3500K
MIN 80CRI
TYPE LAMP MOUNTING DESCRIPTION
AIR CRAFT
CABLE
MOUNTED,
ADJUST-
ABLE
4' LED STRIP ENCLOSED AND GASKETED
FIXTURE. UL 5VA FIBERGLASS HOUSING
WITH WHITE FINISH AND TAMPER
RESISTANT POLYCARBONATE LATCHES,
RIBBED, FROSTED ACRYLIC LENS, LED
FIXED OUTPUT DRIVER,
120V, UL WET LISTED.
LED
53W
4900 LM
3500K
MIN 80CRI
TYPE LAMP MOUNTING DESCRIPTION
STEM
MOUNTED
7" DIAMETER ROUND LED DOWNLIGHT.
STEEL PAN/PLASTER FRAME HOUSING.
EXTRUDED ALUMINUM HEAT SINK.
LOW IRIDESCENT ALUMINUM
REFLECTOR WITH CLEAR
SEMI-SPECULAR FINISH. MATTE WHITE
TRIM. CONSTANT CURRENT CLASS 2
LED DRIVER, 120V, CETLUS DAMP
LISTED.
RECESSED
LED
19W
1500 LM
3500K
MIN 80CRI
TYPE LAMP MOUNTING DESCRIPTION
J
K
TYPE
RECESSED
LAMP MOUNTING DESCRIPTION
L
M
LATCH
MOLDED PLASTIC
48"
7.5"-8.25" ADJ.
DESCRIPTIONMOUNTINGLAMPTYPE
RECESSED
GRID
2'x4' HIGH PERFORMANCE RECESSED
FIXTURE. 4" DEEP, STEEL HOUSING
WITH STEEL REFLECTORS IN MATTE
WHITE ENAMEL FINISH. DIFFUSE
CENTER OPTIC WITH UV-STABILIZED
AND IMPACT RESISTANT ACRYLIC
LENS. STANDARD OUTPUT LED LIGHT
ENGINE, HIGH PERFORMANCE LED
DRIVER, 94.4% POWER FACTOR. 120V
SIMILAR AS TYPE D, EXCEPT WITH
EMERGENCY BATTERY PACK &
CHARGER.
D
D1
REFLECTOR 20…