B.08.03 Drawing S-502.1 (Amended).pdf
PDF 163 KB Posted
- Attached to
- Tainter Gate Painting (5-15), Ozark Lock and Dam
- Solicitation number
- W9127S22R0003
About this file
This document package includes engineering drawings and specifications for a federal contract solicitation. The solicitation is for tainter gate painting services at the Ozark Lock and Dam, part of the McClellan-Kerr Arkansas River Navigation System in Franklin County, Arkansas. The estimated value of the construction is between $5 million and $15 million. It is a total small business set-aside under NAICS code 237990 for other heavy and civil engineering construction. A mandatory site visit is scheduled for February 3, 2022 and questions can be submitted through Projnet until February 14, 2022. The U.S. Army Corps of Engineers Little Rock District is the contracting agency. The engineering drawings provide details for repair and replacement of tainter gate components and coatings.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
S O
L
IC
IT
A
T
IO
N N
O
D E
S
IG
N E
D B
Y
D E
S C
R
IP
T
IO
N
A
M A
R K
S I Z
E
S U
B M
IT
T
E D
B Y
D A
T E
C O
N T
R A
C T
N O
C
H E
C K
E D
B Y
D R
A W
N B
Y
IS
S
U E
D A
T E
B
C
D
E
F
G
2 3 4 5 6 7 8 9 10
SHEET ID
®of Engineers
US Army Corps
U .S
A
R M
Y C
O R
P S
O F
E N
G
IN
E E
R S
A N
S I
D
U
O P
T
IO
N
U
O P
T
IO
N
T A
IN
T
E R
G A
T E
P A
IN
T
IN
G
-1
F R
A N
K L
IN
C
O U
N T
Y A
R
M c C
L E
L L
A N
K
E R
R A
R K
A N
S A
S R
IV
E
R N
A V
IG
A
T
IO
N S
Y S
T E
M
O Z
A R
K L
O C
K A
N D
D A
M
L
IT
T L
E R
O C
K
A R
K A
N S
A S
L
IT
T L
E R
O C
K D
IS
T
R
IC
T
W
C
A P
IT
A
L A
V E
100% SUBMITTAL
W S
R
/2
11/16"
2 1/2 "
%PRODUCTION DATA 4%%PRODUCTION DATA 3%%PRODUCTION DATA 2%
%PRODUCTION DATA 1%
A3
S -5
.1 .d g n
SIDE SEAL DETAIL
B A
L L
R E
D
C
B A
K E
R
C
H
IL
L
T A
IN
T
E R
G A
T E
D E
T A
IL
S
N B
A R
N E
R
D4 REPLACE WT6 x 22.5
SCALE: 1" = 1'-0"
AND GRIND SMOOTH
REMOVE EXISTING WELDS NOTE:
GIRDER
EXISITING PLATE
WT6 x22.5
REPLACEMENT
EXISTING WT6 x 22.5
EXISTING WT6 x 22.5
3"
R
WT6 x 22.5
MAX.
1/8"
SCALE: 3" = 1'-0"
EXISTING PLATE GIRDER FLANGE
AA
SCALE: 1 1/2" = 1'-0"
CONNECTION DETAIL
1/2
1/8
1 1/2"
EXISTING SIDE SEAL EMBED
EXISTING SKIN PLATE
CONTRACTOR TO VERIFY
R= 36'-0" INSIDE FACE OF SKIN PLATE
A7
SCALE: 3" = 1'-0"
5"
/1
DETAIL - J-BULB
SEE DETAIL A7/S-502
RUBBER J-BULB
TFE COATING
THE GATE IN CLOSED POSITION
INTO SIDE SEAL EMBED WITH
PRE-DEFLECT RUBBER J-BULB SEAL
CURVED L 6" x 4" x 1/2" x CONTINUOUS
2. HOLE SPACING TO MATCH EXISTING
NOTE: 1. CONTRACTOR FIELD VERIFY DIMENSIONS SHOWN TO MATCH EXISTING HOLE LOCATIONS.
7/8"R
1 1/2"
AS REQUIRED TO MATCH EXSTING
11/16" DIAMETER HOLE SPACING
CURVED 3" x 1/16" NEOPRENE GASKET
CURVED STEEL BAR 2 1/2" x 1/2" x CONTINUOUS
CURVED STEEL BAR 2 1/2" x 1/2" x CONTINUOUS
SPACED AT 6" OC
STEEL 5/8" COUNTERSUNK BOLT
SPACED TO MATCH EXISTING
STEEL 5/8" BOLT
CURVED 3 x 1/16" NEOPRENE GASKET
A10
COUNTER SUNK KEEPER PLATE
SCALE: 1"=1"
CJP BACKGOUGE
GMAW WELDING MAY NOT BE FEASIBLE DUE TO CONDITIONS IN FIELD.1.
GENERAL NOTES
EXISTING WT 10.5 x 27.5
S-502.1
/1
/2
A
M E
N D
M E
N T
P
E R
A M
A-A
S-502
File details come from the government source that posted it. Updated .