Enclosure_1_Example_PFD_27MAR19.pdf
PDF 20 KB Posted
- Attached to
- Law Enforcement Training Facility (LETC) -- Dining Facility, Veterans Affiars Campus, North Little Rock, AR
- Solicitation number
- W9127S20R6002
About this file
This sources sought notice is for a dining facility project at the Law Enforcement Training Facility campus of the Veterans Affairs Medical Center in North Little Rock, Arkansas. Interested firms are requested to provide information on their experience with dining facilities over $6.5 million, design-build projects over $6.5 million, designing in challenging topographic and rock conditions, campus complexes, utility relocations and traffic considerations, historical facilities, USACE and VA projects, and proposed teaming arrangements. Responses are due by September 27, 2019. The project involves the design and construction of a new approximately 12,000 square foot dining facility to serve 250-275 students, with potential to serve up to 500 students. The estimated value is between $6-8 million. The schedule includes advertising the first design-build step in December 2019, the second step in April 2020, and awarding the design-build contract in August 2020 with an anticipated completion in April 2022. The soliciting agency is the U.S. Army Corps of Engineers Little Rock District on behalf of the Central Arkansas Veterans Healthcare System.
Enclosure 1 - Example PFD
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Enclosure_5_Option_2_Site_Photos.pdf | ||
| Enclosure_3_Site_Topo.pdf | ||
| Enclosure_2_Site_Plan.pdf | ||
| Enclosure_4_Option_1_Site_Photos.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROGRAM FOR DESIGN
598-406 LETC DINING FACILITY
LETC NEW DINING FACILITY
NLR - LETC CAMPUS
Projected Year: 2020 Midpoint Year: 2021
VISN: 16 State: AR Station ID: 598A0 Station: N. Little Rock
Installation: Eugene J. Towbin Healthcare Center
Project Created: 11 Feb 2019 10:28AM ET by Joel Marriott Space Plan Last Edited: 22 Feb 2019 03:10PM ET by Joel Marriott
Contents List Created: 22 Feb 2019 02:38PM ET by Joel Marriott Contents List Last Edited: 22 Feb 2019 02:39PM ET by Joel Marriott
Report Generated: 27 Mar 2019 10:24AM
Department: 1 - VETERANS CANTEEN SERVICE (206)
Functional Area: 1 - STAFF AND ADMINISTRATIVE AREA
Qty Room Code Room Name Unit Area
Net Area
Const Phase
Const Type
1 OFA09 Office, Veterans Canteen Service Chief 100 100 1 0
1 OFA09 Office, Food Section Assistant Chief 100 100 1 0
1 CASH1 Secure Money Handling Room 120 120 1 0
1 OFA07 Workstation, Clerk 56 56 1 0
1 SL001 Lounge, Staff 210 210 1 0
1 LR001 Locker Room, Staff 122 122 1 0
1 TNPG1 Toilet, Staff 60 60 1 0
1 OFA07 Workstation, Clerk 56 56 1 0
1 OFA07 Workstation, Clerk 56 56 1 0
1 OFA07 Workstation, Clerk 56 56 1 0
1 OFA07 Workstation, Clerk 56 56 1 0
1 OFA09 Office, Food Section Assistant Chief 100 100 1 0
FA Totals: Room Qty: 12 Net Area: 1,092 Gross Area: 1,310
Privacy Act - FOR OFFICIAL USE ONLY
Program For Design (27 Mar 2019 10:24AM)
598-406 LETC DINING FACILITY
LETC NEW DINING FACILITY
NLR - LETC CAMPUS
Functional Area: 7 - FOOD COURT SUPPORT AREA
Qty Room Code Room Name Unit Area
Net Area
Const Phase
Const Type
1 MMRP1 Receiving, Food Court 217 217 1 0
1 SRS01 Storage, Non-Food 217 217 1 0
1 SRS01 Storage, Dry-Food 544 544 1 0
1 RER01 Storage, Refrigerated and Frozen Food 761 761 1 0
1 FSTD1 Food Preparation and Production 740 740 1 0
1 FSDW1 Dish Washing 520 520 1 0
1 FSPW1 Pot Washing Area 198 198 1 0
1 SRHM1 Sanitation and Recycling Area 204 204 1 0
1 JANC1 Housekeeping Aides Closet (HAC) 60 60 1 0
FA Totals: Room Qty: 9 Net Area: 3,461 Gross Area: 4,153
Department: 1 - VETERANS CANTEEN SERVICE (206)
Functional Area: 8 - CAFETERIA SERVING AREA
Qty Room Code Room Name Unit Area
Net Area
Const Phase
Const Type
1 FSSL1 Serving Area 967 967 1 0
FA Totals: Room Qty: 1 Net Area: 967 Gross Area: 1,160
Privacy Act - FOR OFFICIAL USE ONLY
Program For Design (27 Mar 2019 10:24AM)
598-406 LETC DINING FACILITY
Functional Area: 9 - CAFETERIA DINING AREA
Qty Room Code Room Name Unit Area
Net Area
Const Phase
Const Type
1 FSCD1 Dining Area 1,725 1,725 1 0
FA Totals: Room Qty: 1 Net Area: 1,725 Gross Area: 2,070
Department: 1 - VETERANS CANTEEN SERVICE (206)
Functional Area: 10 - VENDING AREA
Qty Room Code Room Name Unit Area
Net Area
Const Phase
Const Type
1 BX001 Vending Machine Area 250 250 1 0
FA Totals: Room Qty: 1 Net Area: 250 Gross Area: 300
Department: 1 - VETERANS CANTEEN SERVICE (206)
Functional Area: 11 - TOILET
Qty Room Code Room Name Unit Area
Net Area
Const Phase
Const Type
1 TNPF3 Toilet, Female 215 215 1 0
1 TNPM3 Toilet, Male 260 260 1 0
FA Totals: Room Qty: 2 Net Area: 475 Gross Area: 570
Dept Totals: Room Qty: 26 Net Area: 7,970 Gross Area: 9,564
Bldg Totals: Room Qty: 26 Net Area: 7,970 Sum of Dept Gross Area: Gross Area: 12,9119,564
Privacy Act - FOR OFFICIAL USE ONLY
Program For Design (27 Mar 2019 10:24AM)
598-406 LETC DINING FACILITY
Building Area Summary And Net to Gross Factor Breakdown
Current Building Factor applied to this Project: 1.35
Building GSF
Current 12,911
Privacy Act - FOR OFFICIAL USE ONLY
Program For Design (27 Mar 2019 10:24AM)
598-406 LETC DINING FACILITY
Report Parameters
Sorted By: Uncompressed to match selection tree
(END OF REPORT)
Privacy Act - FOR OFFICIAL USE ONLY
Program For Design (27 Mar 2019 10:24AM)
598-406 LETC DINING FACILITY
File details come from the government source that posted it. Updated .